Loading...
CAS-23_MINNETONKA MIDDLE SCHOOL WEST-6421 HAZELTINE BOULEVARD) S - ":0 Affidavit of Publication Southwest Newspapers State of Minnesota) )SS. County of Carver ) CITY OF CHANHASSEN CARVER & HENNEPIN COUNTIES Laurie A. Hartmann, being duly sworn, on oath says that she is the publisher or the authorized NOTICE OF PUBLIC agent of the publisher of the newspapers known as the Chaska Herald and the Chanhassen Vil- HEARING PLANNING CASE NO. 2015-23 lager and has full knowledge of the facts herein stated as follows: NOTICE IS HEREBY GIVEN that the Chanhassen Planning (A) These newspapers have complied with the requirements constituting qualification as a legal Commission will hold a public newspaM, as provided by Minnesota Statute 33 1 A.02, 33 IA.07, and other applicable laws, as hearing on Tuesday, October 6, amended. 2015, at 7:00 P.M. in the Council Chambers in Chanhassen City (B) The printed public notice that is attached to this Affidavit and identified as No. L2)1 Hall, 7700 Market Blvd. The was published on the date or dates and in the newspaper stated in the attached Notl M"Mu sa-id purpose of this hearing is to Notice is hereby incorporated as part of this Affidavit- Said notice was cut from die columus of consider a request for an Interim the newspaper specified. Printed below is a copy of the lower case alphabet from A to Z, both Use Permit to permit site grading inclusive, and is hereby acknowledged as being the kind and size of type used in the composition to construct a parking lot and and publication of the Notice: an underground stom chamber system, widen the main entrance/ abcdefghijklmnopqrstuvwxyz exit driveway, and construct new paths between the termis courts at Minnetonka Middle School West. The property is zoned Office and Institutional District (01) and located at 6421 Hazeltine (fy Boulevard. Applicant/owner: Minnetonka Schools, ISD #276. A plan showing the location Subscribed and sworn before me on of the proposal is available for public review on the City's web site at wwwci.chanhassen. mn.us/2015-23 or at City Hall du&� q �day Of jjg_�-4-4-2015 during regular business hours Ali interested persons are mvited to attend this public hearing and express their opinions with respect to this proposal. JYVM�E JEANNETTE BARK Robert Generous, AICP, NTARY PL3LIC - WMESOTA R Senior Planner Wy 00WM'S'V)h FMQPQ Email:bgenerous@ N t1ii, ci.chanhassen.mn.us Phone: 952-227-1131 (Published in the Chanhassen Villager on Thursday, September 24, 201& No. 4198) RATE INFORMATION Lowest classified rate paid by commercial users for comparable space .... $31.20 per column inch Maximum rate a] lowed by law for the above matter ................................ $31.20 M column inch Rate actually charged for the above matter .............................................. S 12.59 per colunm inch 0 CITY OF CHANHASSEN PROPOSED MOTION: PC DATE: October 6, 2015 -C) I CCDATE: October26,2015 M.-� REVIEW DEADLINE: November 7,2015 CASE#: 2015-23 BY: AF, RG, JM, ML, JS "The Chanhassen Planning Commission recommends approval of an Interim Use Permit for site grading in excess of 1,000 cubic yards to allow a parking lot expansion, widen the main entrancelexit driveway, construct new paths between the tennis courts and install stormwater improvements subject to the conditions of approval, and adopts the attached Findings of Fact and Recommendation." SUMMARY OF REQUEST: The applicant is requesting an Interim Use Permit to permit site grading to construct a parking lot and an underground storm chamber system, widen the main entrance/exit driveway, and construct new paths between the tennis courts. LOCATION: 6421 Hazeltine Boulevard (Minnetonka Middle School West) (PID 25-0030000) APPLICANT: Minnetonka Schools, ISD #276 5621 County Road 10 1 Minnetonka, MN 55345 PRESENT ZONING: Office and Institutional District (01) 2020 LAND USE PLAN: ACREAGE: 30.3 acres Public/Semi-Public DENSITY: 0.1 F.A.R. LEVEL OF CITY DISCRETION IN DECISION- MAIUNG: The city has limited discretion in approving or denying interim use permits, based on whether or not the proposal meets the standards outlined in the Zoning Ordinance and city code. If the city finds that all the applicable standards are met, the permit must be approved. This is a quasi-judicial decision. Notice of this public heating has been mailed to all property o-tvners within 500 feet. PROPOSAL/SUMMARY The applicant is requesting an Interim Use Permit to permit site grading to construct a parking lot and an underground storm chamber system, widen the main entrance/exit driveway, and construct new paths between the tennis courts. SCANNED Planning Commission Minnetonka Middle School West IUP — Planning Case 2015-23 October 6, 2015 Page 2 of 6 APPLICABLE REGULATIONS Chapter 7, Article 11, Excavating, Mining, Filling and Grading Chapter 19, Article VII, Surface Water Management Chapter 20, Article IV, Division 5, Interim Use Permits Chapter 20, Article )OU, "Ol" Office and Institutional District BACKGROUND On January 27, 2014, the Chanhassen City Council approved Interim Use Permit #2014-01 for site grading in excess of 1,000 cubic yards to allow a parking lot expansion and stormwater improvements on the south side of the school building as part of the swimming pool project within the building. On January 24, 2011, the Chanhassen City Council approved the interim use permit to permit site grading for the tennis courts at Minnetonka Middle School West Planning Case #2011-01. On February 27, 2006, the Chanhassen City Council approved Interim Use Permit #2006-03 to permit the grading of approximately 3,400 cubic yards for an infiltration basin and drainage swales to reduce downstream erosion and sedimentation along Highway 4 1. On June 9, 2003, the Chanhassen City Council approved Interim Use Permit #2003-02 to pem-�t grading in excess of 1,000 cubic yards to install a storm water pond and reconfigure the bus circulation route and parking area on the north side of the school. ANALYSIS Minnetonka Public Schools is proposing to expand their parking capacity by taking an existing pond and putting it into an underground treatment facility so that they may expand the parking lot over the area currently occupied by pond. This project will increase total impervious surface by 0.95 acre, although 0. 18 acre is currently pond which would be considered impervious under the NRCS curve number methodology. Any additional improvements to the Minnetonka Middle School West campus will be considered part of a common plan and will trigger the volume reduction requirements. The proposed water quality treatment facility will still discharge to the same incised ravine which enters the Minnesota Department of Transportation (MnDOT) right-of-way so is considered an MS4 discharge point and is regulated as such. Planning Commission Minnetonka Middle School West IUP — Planning Case 2015-23 October 6, 2015 Page 3 of 6 The applicant is proposing site improvements that include expansion of the existing driveway access to Highway 41, filling an existing storm water pond and installing a parking area. Staff suggests the following changes: I . Remove the catch basin on the current northern edge of the driveway pavement, extend the 12 -inch RCP to the new edge of the driveway, and install a new CB. 2. It appears that the eastern access to the new parking area is intended to provide ingress only into the parking area. The applicant may want to reduce the width of this access to reduce the likelihood of drivers exiting at this location. 3. Some of the proposed slopes in the green area between the new parking area and the tennis courtare2H:IV. This slope maybe difficult to stabilize and/or maintain. The applicant must provide the proposed haul route to/from the site. Proposed sub -surface storm water chamber system will require a professional design and Sewer & Water Permit. EROSION PREVENTION AND SEDIMENT CONTROL Although the project is below the 1.0 -acre threshold at which point an NPDES Construction Permit is required, the design must still be consistent with Section 19-145. Specifically, the following elements must be incorporated into the plans. 1. Phasing of erosion prevention and sediment control practices shall be shown for both the demolition and the construction phases of the project as well as for final stabilization. 2. No channelized flow conditions shall be created. 3. Energy dissipation shall be placed at all outfalls within 24 hours of connection. 4. The outfall for the underground storage system shall be aligned with the channel. 5. All details must be included with the plans including the rock construction entrance, bioroll installation and inlet protection. 6. A dewatering plan shall be provided to and approved by the city prior to any dewatering of the existing pond. This plan must assure that no sediment or pollutant -laden waters are delivered downstream and that the dewatering does not result in new or accelerated erosion. Planning Commission Minnetonka Middle School West IUP — Planning Case 2015-23 October 6, 2015 Page 4 of 6 DRAINAGE AND STORMWATER MANAGEMENT Section 19-143 states that there may be "No increase in peak discharge rate may result from the proposed project for the I- or 2 -year storm, the 10 -year storm and the 100 -year storm event. Variances may be allowed if computations can be provided which demonstrate no adverse downstream effects will result from the proposed system." This goal is met for the 100 -year event but not for the I -year or I 0 -year event. Given the incised condition of the existing ravine to which this feature discharges, it is unlikely that it can be demonstrated that there will be no "adverse downstream effects." 1. The site must not increase discharge rates over existing conditions for any storm event. 2. The applicant must obtain the appropriate permits from MnDOT. Section 19-144 of city code requires that water is treated to N-URP recommendations or to NPDES standards, whichever is more restrictive. NURP recommendations call for a 90% reduction in TSS and a 60% reduction in TP. NPDES requirements are for a net annual reduction in total phosphorus (TP) and total suspended solids (TSS) over existing conditions. The site does not meet either requirement. Modeled removal efficiencies under developed conditions are 32% for TP and 32% for TSS. The water quality modeling for existing conditions indicates a greater removal efficiency with reductions in TP 34% and TSS of 60%. When viewed on an annual load basis, TP load increases on annual basis by 0.5 pounds over existing pond condition while the TSS load increases on an annual basis by 617 pounds. Storm water best management practices for water quality must result in no net increase in TP and TSS load from existing conditions. LANDSCAPING Minimum requirements for the parking lot landscaping at Minnetonka Middle School West include 2,240 square feet of landscaped area around the lot, four landscape islands or peninsulas, nine trees for the parking lot. The applicant's proposed as compared to the requirements for landscape area and parking lot trees is shown in the following table. Planning Commission Minnetonka Middle School West IUP — Planning Case 2015-23 October 6, 2015 Page 5 of 6 I Required Proposed Vehicular use landscape area 2,240 square feet 0 square feet Trees/parking lot 9 trees 0 trees Islands or peninsulas/parking lot 4 islands/peninsulas 0 islands/peninsulas The applicant does not meet minimum requirements for trees and interior landscaping in the parking lot area. A minimum of four landscape islands or peninsulas are required in the parking lot. Additionally, nine trees are required to be planted in and around the parking area. Staff also recommends perimeter landscaping to match existing vehicular use area. RECOMMENDATION Staff recommends that the Planning Commission approve the Interim Use Permit subject to the following conditions and adoption of the attached Findings of Fact and Recommendation: Proposed sub -surface storm water chamber system will require a professional design and Sewer & Water Permit. 2. The applicant must provide the proposed haul route to/from the site. 3. Erosion prevention and sediment control practices shall be shown for both the demolition and the construction phases of the project as well as for final stabilization. 4. No new channelized flow conditions shall be created. 5. Energy dissipation shall be placed at all outfalls within 24 hours of connection. 6. The outfall for the underground storage system shall be aligned parallel to the channel. All details must be included with the plans including the rock construction entrance, bioroll installation and inlet protection. 8. A dewatering plan shall be provided to and approved by the city prior to any dewatering; of the existing pond. This plan must assure that no sediment or pollutant -laden waters are delivered downstream and that the dewatering does not result in new or accelerated erosion. 9. The site must not increase discharge rates over existing conditions for any storm event. 10. The applicant must obtain the appropriate permits from MnDOT. 11. Storm water best management practices for water quality must result in no net increase in TP and TSS load from existing conditions. Planning Commission Minnetonka Middle School West IUP — Planning Case 2015-23 October 6, 2015 Page 6 of 6 12. The applicant shall install a total of four islands/peninsulas in the parking lot and a minimum of nine deciduous trees. 13. The interior width of the landscape islands or peninsulas shall be ten feet. 14. The applicant shall install perimeter landscaping to correspond to existing parking lot site conditions. 15. Drive aisles for two-way operation are required to be 26 feet wide. ATTACHMENTS I . Findings of Fact and Recommendation. 2. Development Review Application. 3. Project Narrative Prepared by Clifford W. Buhman, P.E., Dated September 3, 2015. 4. Reduced Copy of Demolition and Erosion Control Plan, C I. 5. Reduced Copy of Grading and Drainage Plan, C2. 6. Reduced Copy of Layout Plan, C3. 7. Reduced Copy of Storm Chamber Details, C4. 8. Reduced Copy of Details, C5. 9. Reduced Copy of Exhibit A - 2003 Detention Pond Construction Plan 10. Reduced Copy of Existing Stormwater Drainage Areas, Sheet I of 1. 11. Public Hearing Notice and Mailing List. g.Nplan\2015 planni g c�\2015-23 minnetonka middle school wen iup\staff report iup.doc CITY OF CHANHASSEN CARVER AND HENNEPIN COUNTIES, MINNESOTA FINDINGS OF FACT AND RECOMMENDATION IN RE: Application of Minnetonka Public Schools District 276 for an Interim Use Permit to permit grading in excess of 1,000 cubic yards (Planning Case #2015-23). On October 6, 2015 the Chanhassen Planning Commission met at its regularly scheduled meeting to consider the application of Minnetonka Public Schools District 276 for an interim use permit to allow a parking lot expansion, widen the main entrance/exit driveway, construct new paths between the tennis courts, and stormwater improvements for the property located at 6421 Hazeltine Boulevard. The Planning Commission conducted a public hearing on the proposed interim use which was preceded by published and mailed notice. The Planning Commission heard testimony from all interested persons wishing to speak and now makes the following: FINDINGS OF FACT 1. The property is currently zoned 01, Office Institutional District. 2. The property is guided by the Land Use Plan for Public/Serni-Public use. 3. The legal description of the property is: LEGAL DESCRIPTION The Southwest Quarter (SW 1/4) of the Northwest Ouarter (NW 1/4) of Section Three (3), Township One Hundred Sixteen (116). Range Twenty Three (23) West, according to the U. S. Govemment Survey thereof, excepting therefrom the 35/100ths acres conveyed by deed recorded in the office of the Register of Deeds of Carver County. Minnesota, In Book 8 of Deeds, page 400, and that part thereof conveyed by deed recorded in the office of the Register of Deeds of Carver County, Minnesota, in Book 41 of Deeds, page 322, and subject to the right, title and interest of the State of Minnesota in that strip of land conveyed by deed recorded in the office of the Register of Deeds of Carver County, Minnesota, In Book 33 of Deeds, page 25. Also that part of Lot E. Bordwell Acres, not conveyed by said deed recorded in the office of the Register of Deeds of Carver County, Minnesotc, in Book 41 of Deeds, page 322. Subject to a permanent easement for roadway purposes as recorded in the office of the Register of Deeds of Carver County, Minnesota, in Book 54 of Deeds, page 32- 4. When approving an interim use permit the city uses the standards for a conditional use perrnit, the city must determine the capability of a proposed development with existing and proposed uses. The general issuance standards of the conditional use Section 20-232, include the following 12 items: a. The grading operation will not be detrimental to or endanger the public health, safety, comfort, convenience or general welfare of the neighborhood or the city. The site work will result in the creation of a storm water management system which will improve water quality. b. The grading operation will be consistent with the objectives of the city's comprehensive plan and the zoning code providing additional storm water treatment. The earthwork will be maintaining the site in a form suitable for institutional use which is compatible with the Comprehensive Plan and the zoning code. c. The grading operation will be designed, constructed, operated and maintained so to be compatible in appearance with the existing or intended character of the general vicinity and will not change the essential character of that area because the site improvements will improve the use of the site as well as improve water treatment. d. The grading operation will not be hazardous or disturbing to existing or planned neighboring uses because the grading and drainage will be contained within the site perimeters. Hours of operation are limited and specific conditions of approval will be in place and enforced by the city. e. The grading operation will be served adequately by essential public facilities and services, including streets, police and fire protection, drainage structures, refuse disposal, water and sewer systems and schools; or will be served adequately by such facilities and services provided by the persons or agencies responsible for the establishment of the proposed use. The grading is temporary which does not need to be served by public facilities and services. The proposed grading will improve storm water management in this area. f The grading operation will not create excessive requirements for public facilities and services and will not be detrimental to the economic welfare of the community since this site already contains a school. g. The grading operation will not involve uses, activities, processes, materials, equipment and conditions of operation that will be detrimental to any persons, property or the general welfare due to excessive production of traffic, noise, smoke, fumes, glare, odors, rodents, or trash. The conditions of the approval will provide standards by which the activities should be minimized. PA h. The grading operation will have vehicular approaches to the property which do not create traffic congestion or interfere with traffic or surrounding public thoroughfares. Through the use of signage, limits on the hours of operation, and the limited nature of the operation, traffic impacts will be limited. i. The grading operation will not result in the destruction, loss or damage of solar access, natural, scenic or historic features of major significance. The grading operation is limited. The grading operation will be aesthetically compatible with the area since the grading and re -vegetation of the site will improve the site storm water management. k. The grading operation will not depreciate surrounding property values since the plan will improve the site and its impacts on the surrounding properties. 1. The grading operation will meet standards prescribed for certain uses as provided in Chapter 7, Article III of the Chanhassen City Code. 5. The planning report #2015-23 dated October 6, 2015, prepared by Alyson Fauske, et al, is incorporated herein. RECOMMENDATION The Planning Commission recommends that the City Council approve the interim use permit to permit grading in excess of 1,000 cubic yards to allow a parking lot expansion, widen the main entrance/exit driveway, construct new paths between the tennis courts, and stormwater improvements. ADOPTED by the Chanhassen Planning Commission this 6h day of October, 2015. CHANHASSEN PLANNING COMMISSION W-9 Its Chairman L�� COMMUNITY DEVELOPMENT DEPARTMENT Planning Division — 7700 Market Boulevard SEI 0 8 2 CITY OF CHMIMSEN Mailing Address — P.O. Box 147, Chanhassen, MN 55317 Phone: (952) 227-1300 / Fax: (952) 227-1110 '-4ANHA8SC�PLAN�IN *1 APPLICATION FOR DEVELOPMENT REVIEW Submittal Date: PC Date: A) —i� —/ C� CC Date: 10 —1 60 -Day Review Date: Section 1: Application Type (check all that apply) (Refer to the appropriate Application Checklist for required submittal information that must accompany this application) El Comprehensive Plan Amendment ......................... $600 El Minor MUSA line for failing on-site sewers ..... $100 El Conditional Use Permit (CUP) El Single -Family Residence... ............................. $325 0 All Others .............................. ........ ................. $425 R1 Interim Use Permit (ILIP) $150 El In conjunction with Single -Family Residence.. $325 R1 All Others ......................................................... $500 El Rezoning (REZ) area. El Planned Unit Development (PUD) ........ ......... $750 El Minor Amendment to existing PUD ................ � $100 ElAll Others ...................................... .................. $500 El Sign Plan Review ................................................... $150 El Site Plan Review (SPR) El El Administrative ...................................... ­­ ........ $100 El Commercial/Industrial Districts* ...................... $500 Plus $10 per 1,000 square feet of building area. thousand square feet) $300 Include number of extsto employees: Consolidate Lots .............................................. Include number of new employees: El Residential Districts ......................................... $500 Plus $5 per dwelling unit ( units) Final Plat .......................................................... E] Subdivision (SUB) F Create 3 lots or less ........................................ $300 El Create over 3 lots ....................... $600 + $15 per lot El lots) $200 E] Metes & Bounds (2 lots) ................... .............. $300 Consolidate Lots .............................................. $150 Lot Line Adjustment ....................... ................. $150 El Final Plat .......................................................... $700 E] (includes $450 escrow for attorney costs)* $500 *Additional escrow may be required for other applications through the development contract. El Vacation of Easements/Right-of-way (VAC) ........ $300 (Additional recording fees may apply) El Variance (VAR) .................................................... $200 El Wetland Alteration Permit (WAP) El Single -Family Residence ............................... $150 El All Others ....................................................... $275 El Zoning Appeal ...................................................... $100 E] Zoning Ordinance Amendment (ZOA).. ............... $500 NOTE: When multiple applications are processed concurrently, the appropriate fee shall be charged for each application. 23 Notification Sign (City to install and remove) ................................................................................................................... (ia Property Owners' List within 500' (City to generate after pre -application meeting) .......................................... ....... $3 per address Escrow for Recording Documents (check all that apply) .... ............................... 6 . 5 .... a . d . d . res . s . e s . C5D-�br document . . . . . .... . . . El Conditional Use Permit El Interim Use Permit El Site Plan Agreement EJ Vacation El Variance El Wetland Alteration Permit EJ Metes & Bounds Subdivision (3 docs.) EJ Easements( easements) TOTAL FEE: $870.00 Description of Proposal: New Parking Lot where existing detention pond is located, construction of a new underground storm chamber system, and main entrance/exit drive widening. Property Address or Location: Minnetonka West Middle School, 5421 Hazelting Blvd., Excelsior, MN Parcel #: _SEE ATTACHED Legal Description: - Total Acreage: 30.71 Wetlands Present? Present Zoning: Office and Institutional District (01) Present Land Use Designation: Select One Existing Use of Property: School [:1 Check box is separate narrative is attached. SEE ATTACHED El Yes V1 No Requested Zoning: Office and Institutional District (01) Requested Land Use Designation: Public/Semi-Public �CANNFV SCANNED Section 3: Property Owner and Applicant Information APPLICANT OTHER THAN PROPERTY OWNER: In signing this application, 1, as applicant, represent to have obtained authorization from the property owner to file this application. I agree to be bound by conditions of approval, subject only to the right to object at the hearings on the application or during the appeal period. If this application has not been signed by the property owner, I have attached separate documentation of full legal capacity to file the application. This application should be processed in my name and I am the party whom the City should contact regarding any matter pertaining to this application. I will keep myself informed of the deadlines for submission of material and the progress of this application. I further understand that additional fees may be charged for consulting fees, feasibility studies, etc. with an estimate prior to any authonzation to proceed with the study. I certify that the information and exhibits submitted are true and correct. Name: Contact: Address: Phone: Cfty/State/Zip: Cell: Email- Fax: Signature: Date: PROPERTY OWNER: In signing this application, 1, as property owner, have full legal capacity to, and hereby do, authorize the filing of this application. I understand that conditions of approval are binding and agree to be bound by those conditions, subject only to the right to object at the hearings or during the appeal periods. I will keep myself informed of the deadlines for submission of material and the progress of this application. I further understand that additional fees may be charged for consulting fees, feasibility studies, etc. with an estimate prior to any authorization to proceed with the study. I certify that the information and exhibits submitted are true and correct. Name: Minnetonka Schools, ISD #276 Contact: Paul Bourgeois Address: 5621 County Road 101 Phone: (952) 401-5039 Cfty/State/Zip: Mintonka, MN 55345 Cell (612) 240-5997 Email- 40�N.bo4rbeo�dMinnetonka.kl2'.�nn.us Fax: (952) 401-5032 Signature: VU \_A--� Date. 9/4/15 r, PC H , FiirPF*'r -1116'Aalipp nApfatla"A This application must be completed in full and must be accompanied by all information and plans required by applicable City Ordinance provisions. Before filing this application, refer to the appropriate Application Checklist and confer with the Planning Department to determine the specific ordinance and applicable procedural requirements and fees. A determination of completeness of the application shall be made within 15 business days of application submittal. A written notice of application deficiencies shall be mailed to the applicant within 15 business days of application. PROJECT ENGINEER (if applicable) Name: Inspec Contact: Cliff Buhman Address: 5801 Duluth St. Phone: (763) 546-3434 City/State/Zip: Minneapolis, MIN 55422 Cell: (952) 239-2591 Email: cbuhman@inspec.com Fax: (763) 546-8669 Section 4: Notification Information Who should receive copies of staff reports? *Other Contact Information: [D Property Owner Via: [Z] Email El Mailed Paper Copy Name: El Applicant Via: Email Mailed Paper Copy Address: R] Engineer Via: Email Mailed Paper Copy City/State/Zip: 0 Other* Via: 0 Email E] Mailed Paper Copy Email: INSTRUCTIONS TO APPLICANT: Complete all necessary form fields, then select SAVE FORM to save a copy to your device. PRINT FORM and deliver to city along with required documents and payment. SUBMIT FORM to send a digital copy to the city for processing (required). 5�� EE�� SCANNED rop"O. September 3, 2015 INSPEC City of Chanhassen (ATY0FCHANHASSFN RECEIVED Community Development Department Planning Division SEP 0 8 2015 7700 Market Boulevard Sman engineering of P.O. Box 147 CHANHASSEN PIANNING DEPT Chanhassen, MN 55317 Toofs. walls windows. To Whom It May Concern: pa�enn�nns On behalf of Minnetonka Schools, please find allached the Interim Use Permit (IUP) and Waterproofing Application, check for $870, and the supporting required plans and documents for the proposed construction of a new parking lot at Minnetonka Middle School West. This project is in the location of the existing north detention pond to provide much needed additional parking, construction of a new underground storm chamber system to effectively manage the stormwater runoff from this drainage area, widening of the west main entrance/exit drive for improved traffic flow, and construction of new paths between the tennis courts to provide better access. The following are the amounts for the hard -surface changes: Proposed Parking Lot 0.61 acres Drive Widen 0. 14 acres New Paths 0.20 acres In submitting this application for the School, I acknowledge the following for the proposed project: a. Will not be detrimental to or endanger the public health, safety, comfort, convenience or general welfare of the neighborhood or the city. b. Will be consistent with the objectives of the city's comprehensive plan and this chapter. c. Will be designed, constructed, operated and maintained so to be compatible in appearance with the existing or intended character of the general vicinity and will not change the essential character of that area. d. Will not be hazardous or disturbing to existing or planned neighboring uses. 5801 Duluth street e. Will be served adequately by essential public facilities and services, including Minneapolis. MN 55422 streets, police and fire protection, drainage structures, refuse disposal, water and Ph. 763-546-3434 Fax 763-546-86W sewer systems and schools; or will be served adequately by such facilities and services provided by the persons or agencies responsible for the establishment of the proposed use. Chicago f. Will not create excessive requirements for public facilities and services and will Milwaukee not be detrimental to the economic welfare of the community. Minneapolis g. Will not involve uses, activities, processes, materials, equipment and conditions www.inspec.com of operation that will be detrimental to any persons, property or the general welfare because of excessive production of traffic, noise, smoke, fumes, glare, odors, rodents, or trash. SCANNED Minnetonka Public Schools Minnetonka Middle School West September 3, 2015 Page 2 h. Will have vehicular approaches to the property which do not create traffic congestion or interfere with traffic or surrounding public thoroughfares. i. Will not result in the destruction, loss or damage of solar access, natural, scenic, or historic features of major significance. Will be aesthetically compatible with the area. k. Will not depreciate surrounding property values. 1. Will meet standards prescribed for certain uses as provided in this article. We appreciate the opportunity to work with you and look forward to another successful project. Sincerely, WSPEC P.E. SCANNED KEYED NOTES . ... . ...... 0 El i 131 i WENTAWECT�: cl SCANNED GENERAL NOTES: --- too- Da X 7 67 .. . ......... CITY OF CHANHASSEV ------ RECEIVED SEP 0 8 2015 CHANHASSEN PLANNING DFPT 2 x -...—T. EROSION CONTROL NOTES: DEMOLITIONAND EF�OS?N CO�TROL PLAN 2 MINNETONKA 2 F SCHOOLS < 9 F, WEST MIDDLE SCHOOL so 8 1052 IMPROVEMENTS AND !ILT DU� PARKING LOT ADDITION DEMOLITION AND ----- ---- P EROSION CONTROL PLAN WENTAWECT�: cl SCANNED SCANNED xw All I Q jr—, M�J� mjoxi� pa I , mim-dil — 1210-4 1 I . GIRADING AND DRAINAGE PLAN . . . . . . . . . . I law MIAMI �iiiiii, IC: I lill lill P�l plifill"i SCANNED FA, mw �-.4 w I LAYOUT PLAN I 1� . -(3 ---------- ------------- too - �,�ITY OF CHANHASSEN RECEIVED SEP 0 8 2015 (' HANHASSEN PLANNING DEPT -1 MINNETONKA SCHOOLS WEST MIDDLE SCHOOL 77777= IMPROVEMENTS AND PARKING LOT ADDITION �T P� SCANNED UIENT �WECT C3 SCANNED GENERAL NOTES 16- e2aET ELEVATIONS 1LANDARD MC -4500 CROSS SECT10N W� %)�L-4501EH MUR LAYOUT Pi PVATI �Nq � 7x 11 A qDl��OLATOR ROW 'PROFILE VIEW MAL - am I g)ISOLATOR ROW 'IJANIFOLD �rrFPTARI F Fil I MATFRIAI q STORM WATER CHAMBER SYSTEMS STORM WATER CHAMBERS ACCEPTABLE MATERIALS 61TYUCHANWASSEN RECEIVED SEP 0 8 2015 CHANHASSEN ftANNINGOF.01 I mr� MINNETONKA SCHOOLS WEST MIDDLE SCHOOL 2016 STORM DRAIN IMPROVEMENTSAND PARKING LOT ADDITION �TE �L..T �.M� P OJE� CA SCANNED A�M M43 MOAT. MWO U145 CWPAON(KXS� KQURE.E. Z STORM WATER CHAMBERS ACCEPTABLE MATERIALS 61TYUCHANWASSEN RECEIVED SEP 0 8 2015 CHANHASSEN ftANNINGOF.01 I mr� MINNETONKA SCHOOLS WEST MIDDLE SCHOOL 2016 STORM DRAIN IMPROVEMENTSAND PARKING LOT ADDITION �TE �L..T �.M� P OJE� CA SCANNED I ttl ;Bztlg CURB A GUTTER DETAIL u NYLOPILAST �HOLE AND �ATCH ILLSIN DETAI� NEW FILMTM ML. DUAL � WIVOILE N DETAIL WITH WEIR AND WIL WFI-E SURMUWAINLE WLT E-C.ETE ..- DETAL SUMOUNTABLE O�Lff (j)C.ONG ETECURSDETAIL .4 @ A.=MISLE �P W. PIPE BEDDING DETAIL &URED END WITH TRASH GUARD SE� TPR�P AT FLARED END DETAIL top. Iff Mp�c . — . . . ............ ,;ITY0FCHANHAS3EI`l RECEIVED SEP 0 8 2015 (,HANHOSSENPLAINING DEPT I MINNETONKA SCHOOLS WEST MIDDLE SCHOOL 7777;7= .,MEMENI . AND PARKING LOT ADDITION .E FRWEU� C5 SCANNED 4bb CITY OFCHANHASSEt' RECEIVED SEP 0 8 2015 prZ CHANVSSEN PLANNAGOFP11' or z 9==— PEP— % 7 4tr I nRAD14G WLAN 2003 PAVEMENT REIIABUTATIC04 MONETORKA MME SOIM WEST .LN MK4ETONKA PUPAIC SCHOOt% CHAWASSER MhqSOTA EXHIBIT A Minnetonka Schools — West Middle School 2003 Detention Pond Construction with 2003 Pavement Rehabilitation Project SCANNED EXIST. S�MWATER AREAS mEwDr mu �o &A#VEU ACllS 60��HOYY E ACW--1 E U - - -------------- -------- ------- Z� EXISTING STORMWATER DRAINAGE AREAS mEwDr mu �o &A#VEU ACllS 60��HOYY E ACW--1 E U SCANNED toll- iff INSPEC 0 mp�� 61- SE .yoF:CHANHAS^ 0 RECEIVED SEP o 8 2015 MINNETONKA PUBLIC SCHOOLS ISO - 276 MINNETONKA MIDDLE SCHOOL WEST SHT 1 OF 1 - - -------------- -------- ------- Z� EXISTING STORMWATER DRAINAGE AREAS SCANNED toll- iff INSPEC 0 mp�� 61- SE .yoF:CHANHAS^ 0 RECEIVED SEP o 8 2015 MINNETONKA PUBLIC SCHOOLS ISO - 276 MINNETONKA MIDDLE SCHOOL WEST SHT 1 OF 1 CITY OF CHANHASSEN AFFIDAVIT OF MAILING NOTICE STATE OF MINNESOTA) )ss. COUNTY OF CARVER ) 1, Karen J. Engelhardt, being first duly sworn, on oath deposes that she is and was on September 24, 2015, the duly qualified and acting Deputy Clerk of the City of Chanhassen, Minnesota; that on said date she caused to be mailed a copy of the attached notice of Public Hearing for Minnetonka Middle School West Interim Use Permit – Planning Case 2015-23 to the persons named on attached Exhibit "A", by enclosing a copy of said notice in an envelope addressed to such owner, and depositing the envelopes addressed to all such owners in the United States mail with postage fially prepaid thereon; that the names and addresses of such owners were those appearing as such by the records of the County Treasurer, Carver County, Minnesota, and by other appropriate records. Subscribed and sworn to before me this,%A—h day of–�v aAcm by r 2015. L A Notary Pubhv� Katmi J. Engelt�dt, Dep* Clerk #KIM T. MEUWISSEN i Notary Rb"hnesoft M m= Y CO—Adbm E vin. A. 31. 2020 Notice of Public Hearing Chanhassen Planning Commission Meeting Date & Time: Tuesday, October 6, 2015 at 7:00 P.M. This hearing may not start until later in the evenin , depending on the order of the agenda. Location: City Hall Council Chambers, 7700 Market Blvd. Request for an Interim Use Permit to permit site grading to construct a parking lot and an underground storm chamber Proposal: system, widen the main driveway, and construct new paths between the tennis courts at Minnetonka Middle School West. The property is zoned Office and Institutional District (01). Applicant: Minnetonka Schools, ISD #276 P;-operty 6421 Hazeltine Boulevard Location: A location map is on the reverse side of this notice. The purpose of this public hearing is to inform you about the applicant's request and to obtain input from the neighborhood about this project. During the meeting, the Chair will lead the What Happens public hearing through the following steps: at the Meeting: 1. Staff will give an overview of the proposed project. at the Meeting: 2. The applicant will present plans on the project. 3. Comments are received from the public. 4. Public hearing is closed and the Commission discusses the project. If you want to see the plans before the meeting, please visit the City's projects web page at: www.cl.chanhassen.mn.us/2015-23. If you wish to talk to someone about this project, please contact Robert Generous Questions & by email at bqenerouseci.chanhassen.mn.us or by phone at Comments: 952-227-1131. If you choose to submit written comments, it is helpful to have one copy to the department in advance of the meeting. Staff will provide copies to the Commission. The staff report for this item will be available online on the project web site listed above the Thursday prior to the 1 Planning Commission meeting. NEWI Sign up to receive email and/or text notifications when meeting agendas, packets, minutes and videos are uploaded to the city's website. Go to www.ci.chanhassen.mn.us/notifyme to sign up! City litandew Procedure: • Subdivisions, Planned Unit Developments, Site Plan Reviews, Conditional and Interim Uses, Welland Alterations, Rezonings, Comprehensive Plan Amendments and Code Amendments require a public hearing before the Manning Commission. City ordinances require all property wthin 500 fact of the subject site to be nailed of the application in wifing. Any interested party Is liNted to attend the meeting. • Staff prepai a report on Me subject application that Includes all pendent Information and a recommendation. These reports are available by request. At the Planning Commission meting, staff will give a verbal overview of the report and a recommendation. The Item will be opened for the public to speak about the proposal as a pan of the hearing process, The Commission will close the public hearing and discuss the item and make a reconfirenclation to the City Council. The City Council may reverse, affirm or modify wholly or partly the Planning Commission a recommendation. Remnings, land use and code amendments take a simple majority vote of the City Counal except rezonings add land use amendments from residemmal to commercialAndustrial. • Minnesota State Statute 519.99 requires all applications to be processed within 60 days unless the applicant waives this standard. Some applications due to their complaxity may take sevn�ral months to complete. Any person wshing to follow an item through the process should check with the Manning Department regarding its status and scheduling for the City Council Meting. • A neighborhood slookespersonlrepressentabve Is encouraged to provide a contact for the dry. Often developers are encouraged to meet Win the neighborhood regarding their proposal. Staff is also available 0 review the mied wth any interested person(s). • Because the Ramming Commission holds the public hei the Dry Ccjuncil does not. Minutes are taken and any correspondence regarding the application will be induced In the report to Me City Council. ff you Wish to he" something to be included in Me report. please contact the planning Suff person named on the notification. Notice of Public Hearing Chanhassen Planning Commission Meeting Date & Time: Tuesday, October 6, 2015 at 7:00 P.M. This hearing may not start until later In the evening, depending on the order of the agenda. Location: City Hall Council Chambers, 7700 Market Blvd. Request for an Interim Use Permit to permit site grading to construct a parking lot and an underground storm chamber Proposal: system, widen the main driveway, and construct new paths between the tennis courts at Minnetonka Middle School West. The property is zoned Office and Institutional District (01). Applicant: Minnetonka Schools, ISD #276 Property 6421 Hazeltine Boulevard Location: A location map Is on the reverse side of this notice. The purpose of this public hearing is to inform you about the applicant's request and to obtain input from the neighborhood about this project. During the meeting, the Chair will lead the What Ha ens pp public hearing through the following steps: 1 . Staff will give an overview of the proposed project. at the Meeting: 2. The applicant will present plans on the project. 3. Comments are received from the public. 4. Public hearing is closed and the Commission discusses the project. If you want to see the plans before the meeting, please visit the City's projects web page at: www.cl.chanhassen.mn.us/2015-23. If you wish to talk to someone about this project, please contact Robert Generous Questions & by email at baenerous(cDci.chanhassen.mn.us or by phone at Comments: 952-227-1131. If you choose to submit written comments, it is helpful to have one copy to the department in advance of the meeting. Staff will provide copies to the Commission. The staff report for this Item will be available online on the project web site listed above the Thursday prior to the 1 Planning Commission meeting. NEWI Sign up to receive email and/or text notifications when meeting agendas, packets, minutes and videos are uploaded to the city's website. Go to www.ci.chanhassen.mn.us/notifyme to sign up! City Review Procedure; • Subdivisions manned Unit Developments. Site Ran Reviews, Conditional and [mod. Uses, Weiland Alterations, Reirmings, Comprehensive Plan Amendments and Code Amendments require a public hearing before the Planning Commission. City ordinances require all property within 500 fact of Me subject site to be notified of the application In wflOng. Any interested party is invited to attend the meting. • Staff prepares a report on Me subject applicaflon that induces all pertinent information and a recommendation. These reports are available by heourinn. At the Planning Commission meeting, staff will give a verbal ovary" at the report and a recommendation. The item will lost opened for the public to speak about the proposal as a pad of the hearing process, The Commission will dose the public hearing and discuss the item and make a recommendation to the City Council. The City Council may reverse, affind or modify wholl y a partly the Planning Commission's recommendation. Rezonings, land use and cods amendments take a simple majority vote of the City Cotnal except nazonlini and land use amendments from residential to commerciallindustral, • Minnesota State Statute 519.99 requires all applications to be processed wthin 60 days unless the applicant waives this standard. Some applications due to their complexity may take several months to complete. Any person wishing to follow an item through Me process should check with the Planning Department regarding Its status and scheduling for the City Council meaning. • A neighborhood spokespersonlreoressintative is encouraged to provide a contact for the city. Often developers are encouraged to mead Wth the neIghbomodil regarding their proposal. Staff Is also available to review Me prjed with any interested oruirsons). • Because the Manning Commiisskm holds the public hei Me City Cotmcil does not. Minutes are taken and any correspondence regarding the application *11 be included in the report to the Cry Council. N you wish 0 he" something to be included in the mod, please contact the Planning Staff person named on the noUlicari ADAM CUNNINGHAM BENJAMIN H & HIDEKO GOWEN BRIAN D & KRISTINE V MCMENAMIN 2221 SOMMERGATE 6440 HAZELTINE BLVD 6393 MELODY LN EXCELSIOR EXCELSIOR EXCELSIOR MN 55331-8800 MN 55331-8049 MN 55331-6405 CAROL ASLESEN CHILD 6482 MURRAY HILL RD EXCELSIOR MN 55331-8994 CARVER COUNTY 602 4TH ST E CHASKA MN 55318-2102 CHARLES R & JOANNE F LEWELLEN CHRISTOPHER NOVOGRATZ 6340 MURRAY HILL RD 6624 ALDER WAY EXCELSIOR CHANHASSEN MN 55331-8834 MN 55317-4581 CHARLES G GOERS SR REV TRUST 2160 MURRAY HILL CT EXCELSIOR MIN 55331-8882 CHRISTOPHER OHLAND 6285 CHASKA RD EXCELSIOR MN 55331-8824 CINDY TELLINGHUISEN CLAUDE W & KAYE L BENSON CURTIS W & NOELLE W SWENSON 6370 MURRAY HILL RD 2211 SOMMERGATE 6614 ALDER WAY EXCELSIOR EXCELSIOR CHANHASSEN MIN 55331-8834 MN 55331-8800 MN 55317-4581 DALEJOHANSEN DAMON M JOHNSON DAN V & CYNTHIA M SEEMAN 2240 MELODY HILL RD 6366 MELODY LN 6673 BRENDEN CT EXCELSIOR EXCELSIOR CHANHASSEN MN 55331-8891 MN 55331-6402 MN 55317-7560 DANIEL C & JANE A MCKOWN DANIEL M PESCHEL DANIEL REICH 2171 PINEHURST DR 2220 MELODY HILL RD 6378 MELODY LN CHANHASSEN EXCELSIOR EXCELSIOR MN 55317-4579 MN 55331-8891 MN 55331-6402 DAVID L & MARY JO WILLADSEN DENNIS M & JOAN E CLARK DONNA SAJADY 2325 MELODY HILL RD 6651 HAZELTINE BLVD 6610 BRIENDEN CT EXCELSIOR EXCELSIOR CHANHASSEN MN 55331-8894 MN 55331-8039 MN 55317-7560 DOUGLAS E & MARY K JOHNSON GARRETT TRAPNELL GREGORY IRL NELSON REV 6474 MURRAY HILL RD 2280 MELODY HILL RD 2165 MURRAY HILL CT EXCELSIOR EXCELSIOR EXCELSIOR MN 55331-8994 MN 55331-8891 MN 55331-8882 IND SCHOOL DIST 276 JAMES A PEDERSON JAMES R FERRIN 5621 COUNTY ROAD 101 6654 BRENDEN CT 6444 MURRAY HILL RD MINNETONKA CHANHASSEN EXCELSIOR MN 55345-4214 MN 55317-7560 MIN 55331-8994 JANE QUILLING REVSBECH JASON REYNOLDS JEANNE NELSON 2155 MURRAY HILL CT 6390 MELODY LN 6613 BRENDEN CT EXCELSIOR EXCELSIOR CHANHASSEN MN 55331-8882 MN 55331-6402 MIN 55317-7560 JEFFREY A & CHRISTINA M WUNROW JOHN D & KATHRYN D DESMET JOHN J & LYNNETTE J DELUCA 6361 MELODY LN 6454 MURRAY HILL RD 6484 MURRAY HILL RD EXCELSIOR EXCELSIOR EXCELSIOR MN 55331-6405 MN 55331-8994 MN 55331-8994 JOHN R BORRELL KEITH K & CHRISTINE M CLARK KEVIN J DEGEL 2160 PINEHURST DR 6620 CHESTNUT LN 6610 CHESTNUT LN CHANHASSEN CHANHASSEN CHANHASSEN MN 55317-4579 MN 55317-4580 MN 55317-4580 KUAN-CHENG SU KYIN ONG LOK LEIF W OLSEN 2180 CRESTVIEW DR 2170 PINEHURST DR 2150 PINEHURST DR EXCELSIOR CHANHASSEN CHANHASSEN MN 55331-8009 MN 55317-4579 MN 55317-4579 LESLIE A POLTRACK LYNDA M KUZMA MARK S & LORENA M FLANNERY 164 DOUD DR 2241 SOMMERGATE 2350 MELODY HILL RD LOS ALTOS EXCELSIOR EXCELSIOR CA 94022-2369 MN 55331-8800 MN 55331-8893 MATTHEW ALLAN KLOSKOWSKI MATTHEW M QUINN MICHAEL C & MARGARET L 6287 CHASKA RD 6604 ALDER WAY BUCHNER EXCELSIOR CHANHASSEN 2191 SOMMERGATE EXCELSIOR MN 55331-8824 MN 55317-4581 MN 55331-8917 MICHAEL C TOBIN MICHAEL D & DEBRA H ANDERSON MYKE L & LYNN S MILLER 6377 MELODY LN 6681 AMBERWOOD LN 6405 MELODY LN EXCELSIOR CHANHASSEN EXCELSIOR MN 55331-6405 MN 55317-4582 MN 55331-6404 PAUL J & JUDITH A POITEVENT PAUL J & KRISTI L BORCHERT RAYMOND H MURRAY 2300 MELODY HILL RD 6636 BRENDEN CT 6618 BRENDEN CT EXCELSIOR CHANHASSEN CHANHASSEN MN 55331-8893 MN 55317-7560 MN 55317-7560 RICHARD D BLISS ROBERT & JERI LOU PRCHAL ROBERT A JR & BRENDA K NESS 6400 MELODY LN 2150 MURRAY HILL CT 2121 CRESTVIEW DR EXCELSIOR EXCELSIOR EXCELSIOR MN 55331-6403 MN 55331-8882 MN 55331-8010 ROBERT E LEE III RYAN QUADE SPENCER L GOLDSMITH 16827 WILLOW LN SW 2181 PINEHURST DR 2231 SOMMERGATE PRIOR LAKE CHANHASSEN EXCELSIOR MN 55372-2364 MN 553174579 MN 55331-8800 STEVEN J WALSTROM STEVEN P & KIMBERLY A LATTU STEVENS INVESTMENTS LLC 6464 MURRAY HILL RD 2181 CRESTVIEW DR 6505 FOX HOLLOW CT EXCELSIOR EXCELSIOR CHANHASSEN MN 55331-8994 MN 55331-8010 MN 55317-9265 THOMAS G & NEYSA L WINTERER THOMAS J & REBECCA J HAGEN TIMOTHY P & HEIDI S LARKIN 2210 MELODY HILL RD 6633 BRENDEN CT 2150 CRESTVIEW DR EXCELSIOR CHANHASSEN EXCELSIOR MN 55331-8891 MN 55317-7560 MN 55331-8009 WILLIAM DOUGLAS HILE WILLIAM 0 & KRISTEN K FLANAGAN WILLIAM R GUPTAIL 2151 CRESTVIEW DR 6653 BRENDEN CT 2180 PINEHURST DR EXCELSIOR CHANHASSEN CHANHASSEN MN 55331-8010 MN 55317-7560 MN 55317-4579 COMMUNITY DEVELOPMENT DEPARTMENT Planning Division — 7700 Market Boulevard Mailing Address — P.O. Box 147, Chanhassen, MN 55317 Phone: (952) 227-1130 / Fax: (952) 227-1110 * CITY OF CHMHASSEN AGENCY REVIEW REQUEST LAND DEVELOPMENT PROPOSAL I Please review and respond no later than the review response deadline Agency Review Request Date: September 10, 2015 Agency Review Response Deadline: September 24, 2015 Date Application Filed: September 8, 2015 Contact: Contact Phone: Contact Email: Robert Generous, AICP 952-227-1131 bgenerous@ci.chanhassen.mn.us Senior Planner Building Official Planning Commission Date: City Council Date: 60 -Day Review Period Deadline: October 6, 2015 at 7:00 p.m. October 26, 2015 at 7:00 p.m. November 7, 2015 Request for Interim Use Permit to permit site grading to construct a parking lot and an underground storm chamber system, widen the main entrance/exit driveway, and construct new paths between the tennis courts. The property is zoned Office and Institutional District (01) and located at 6421 Hazeltine Boulevard. Applicant/Owner: Minnetonka Schools, ISD #276. Planning Case: 2015-23 1 Web Page: www.ci.chanhassen.mn.us/2015-23 In order for staff to provide a complete analysis of issues for Planning Commission and City Council review, we would appreciate your comments and recommendations concerning the impact of this proposal on traffic circulation, existing and proposed future utility services, storm water drainage, and the need for acquiring public lands or easements for park sites, street extensions or improvements, and utilities. Where specific needs or problems exist, we would like to have a written report to this effect from the agency concerned so that we can make a recommendation to the Planning Commission and City Council. Your cooperation and assistance is greatly appreciated. City Departments: Federal Aciencies: Adoacent Cities: Attorney Ej Army Corps of Engineers E1 Chaska Building Official US Fish & Wildlife F1 Eden Prairie Engineer El Jackson Township Fire Marshal Watershed Districts: 0 Minnetonka Z • Forester Park Director El CarverCountyWMO El El Shorewood Victoria • Water Resources El Lower MN River El Law Enforcement N Minnehaha Creek Achacent Counties: El Riley -Purgatory -Bluff Creek Carver County Agencies: Ej Hennepin Utilities: El Scott El Community Development El Cable TV Mediacom El Engineer El — Electric Minnesota Valley School Districts: El Environmental Services — El Historical Society 0 Electric — Xcel Energy Eastern Carver County 112 Parks El Magellan Pipeline Minnetonka 276 Soil & Water Conservation District El Natural Gas — CenterPoint Energy El Phone — Centuryl-ink Other Aaencies: State Agencies: El Hennepin County Regional Railroad El Board of Water & Soil Resources Authority El Health MN Landscape Arboretum El Historical Society SouthWest Transit El Natural Resources -Forestry El TC&W Railroad D Natural Resources -Hydrology Pollution Control Transportation Generous, Bob From: lynn miller <Iynn_s_geldert@hotmaii.com> Sent: Wednesday, September 30, 2015 10:51 AM To: Generous, Bob Cc: Myke Miller, nancyjohnson@outlook.com; Gail Pratt; Jessica Miller Subject: 2015-23 Minnetonka Middle School West Interim Use Permit My name is Lynn Miller and I reside at 6405 Melody Lane. I've lived here since 1999. 1 endured the past parking lot construction and the tennis courts construction. I do not want to live through that type of construction again. My concerns are: 1. Apparent lack of thought, expertise and concern for neighbors during past construction, more important the tennis courts construction. Lack of access to the courts and consideration for drainage seem to be glaring instances of lack of expertise and concern for neighbors and children. 2. Currently the trees and shrubs between the school and tennis courts with the neighboring houses is very important. I would like to know the plan for retaining and protecting the trees and shrubs during construction. 3. Construction of the current parking lot during the summer made our outdoor spaces unusable due to constant dirt in the air. We could not be outside for any length of time that summer. That needs to be addresses during future construction. 4. We hear talk about how important getting outdoors and connecting with nature is for children, I'm concerned about more asphalt being added to Minnetonka Middle School west. Are cars more important than our children? Are periodic tournaments more important than every day use by children in the environment? I don't believe so. 5. A stop light that works during school hours is needed to regulate traffic on Highway 41 and cars exiting the school. Why is that not implemented? 6. Please let me know the most effective way to be heard on the 2015-23 Minnetonka Middle School West Interim Use Permit. I live here. I'm in this neighborhood every day, 24 hours a day. I hope someone is available to incorporate my concerns into the new plans for parking, driveway and drainage. I look forward to hearing from you. Lynn Miller 6405 Melody Lane Excelsior, MN 55331 952-474-8123 home Sent from my iPad Generous, Bob From: Generous, Bob Sent: Tuesday, October 06, 2015 11:51 AM To: 'Mike T Cc: Jeffery, Terry; Fauske, Alyson; Sinclair, Jill; 'Bourgeois, Paul' Subject: RE: Minnetonka Public Schools, ISID #276 Mike, This item has been withdrawn from the planning commission agenda. They may be coming back with a scaled down plan that only addresses the turn lane, which may not require a public hearing. I am copying the school district on your email so they can see your concerns. If you have additional questions or need more information, please contact me. MIZ Robert Generous, AICP Senior Planner 7700 Market Boulevard P.O.Box 147 Chanhassen, MN 55317 (952) 227-1131 bgenerous@ci.chanhassen.mn.us Chanhassen is a Community for Life— Providingfor Today and Planningfor Tomorrow From: Mike T [mailto:mike.c.tobin@gmail.com] Sent: Tuesday, October 06, 2015 9:04 AM To: Generous, Bob Subject: Minnetonka Public Schools, ISD #276 Mr. Generous, I am writing regarding the proposed development at Minnetonka Public Schools 6421 Hazeltine Boulevard (MMW). As a neighbor to this property, I am generally supportive of the proposal and the recommendations of the city staff. Of particular importance to me and my neighbors is the landscaping plan which was absent in the proposal. I am glad that the staff highlighted this in the report and made the submittal of a plan mandatory. Although we could not determine if the staff was recommending a landscaping plan that was under the minimum code requirements. We would strongly recommend that the landscaping plan at least meet the code minimum if not exceed it. Exceeding the code minimum would be welcomed considering that the parking lot is replacing an area that has substantial natural plants, trees and other wildlife. In addition, we would like to recommend that the City and School review this landscaping and the rest of the landscaping around the tennis courts for a period of at least 2 years to ensure that the landscaping has successfully taken root. We have been very disappointed in the landscaping that was done during the development of the tennis courts a few years ago where —5 evergreen trees were planted too close to the perimeter fence and the majority of them died within I year and were never replaced. The result is now a series of dead evergreens surrounded by invasive buckthorn and other invasive vines which do not achieve a good landscape buffer for the large chain link fencing associated with the courts. I appreciate your consideration and that of the council of our concerns and look forward to hearing the response - Best regards, Mike Tobin 6377 Melody Lane Excelsior, MN 55331 F�roperty Card Parcel ID Number 250033000 I Taxpayer Information I Taxpayer Name IND SCHOOL DIST 276 5621 COUNTY ROAD 101 MINNETONKA, MN 55345-4214 Property Address Address 6421 HAZELTINE BLVD City EXCELSIOR, MN 55331 Parcel Information Uses Schools -Public GIS Acres 30.62 NetAcres 30.62 Deeded Acres 30.71 Plat Lot I Block IN SW114 NW1/4 AS SURVEYED Building Information Estimated Market Value Building Style Above Grade Finished So Ft Bedrooms I Year Built Garage N I Bathrooms Miscellaneous Information School District Watershed District Homestead Green Acres Ag Preserve 0276 1 WS 062 MINNEHAHA I I N I N Assessor Information Estimated Market Value 2014 Values (Payable 2015) 2015 Values (Payable 2016) Last Sale Land $3,348,000.00 $3,348,000.00 Date of Sale Budding $13,809,500.00 $13,385,300.00 Sale Value Total $17,157,500.00 $16,733,300.00 1 1 The data provided hersydr, is for refer ence purposes only This deters not suitable for legal enamfeenng, surveying or other Shir purposes Carver County does not guarantee the accuracy of the mfonn a on contained herein This data is furnished an an as is basis awd Carver County makes no representations or warranties either expressedi or implied for the merchantability or fitness of the inforna: . provided for any purpose. This disclaimer d; provided pursuant to Minnesota Star §�.03 and the user of the data pro deed hars. adlinawfackes that Carver Coure, small war be liable for arty damages and by shng this cale in any way expressly waves all station, anal agrees to defeard! mdamnly and hold har'"Wes Ca�df County its officials offir agents empfoyces, etc from any ancl all claims brourmt by anyone who uses thic information provided for herein its ernployshas or agents or m CARVER Mind parties which arms cut of users access By acceptance of Mis case the user agrees not to transmit this data or prowde access to it a any pan 0 it to another party unless Me user includes COLJNTy with the data . copy of this doi,lainne, Thursday, September 10, 2015 Carver County. MN COMMUNITY DEVELOPMENT DEPARTMENT Planning Division - 7700 Market Boulevard 08 M Phone: (952) 227 "'P CIff OF CHINSEN ailing Address - P.O. Box 147, Chanhassen, MIN 55317 -1300 / Fax: (952) 227-1110 1 t4iil�SS&4paNNIN *3 APPLICATION FOR DEVELOPMENT REVIEW Submittal Date. PC Date: 10 —le- - CC Date: 6 -.4/0 6D -Day Review Date: Section 1: Application Type (check all that apply) (Refer to the appropriate Application Checklist for required submittal information that must accompany this application) Comprehensive Plan Amendment..... .................... $600 El Minor MUSA line for failing on-site sewers ..... $100 El Conditional Use Permit (CUP) El Single -Family Residence ........................ ....... $325 0 All Others ......................................................... $425 Z Interim Use Permit (IUP) Sign Plan Review ................................................... El In conjunction with Single -Family Residence.. $325 Z All Others ............................... El Administrative ............................... .................. El Rezoning (REZ) El Metes & Bounds (2 lots) .................................. El Planned Unit Development (PUD) .................. $750 El Minor Amendment to existing PUD ................. $100 El All Others ......................................................... $500 El Sign Plan Review ................................................... $150 El Site Plan Review (SPR) lots) El Administrative ............................... .................. $100 El Metes & Bounds (2 lots) .................................. El Commercial/industrial Districts* ........... .......... $500 El Consolidate Lots .............................................. Plus $10 per 1,000 square feet of building area.. El Lot Line Adjustment. ........................................ thousand square feet) El Final Plat .......................................................... *Include number of existin employees: (Includes $450 escrow for attorney costs)* *nclude number of new employees: *Additional escrow may be required for other applications El Residential Districts ... .................. .................. $500 Plus $5 per dwelling unit ( units) Vacation of Easements/Right-of-way (VAC) ........ $300 Notification Sign (City to install and remove) ......................... (Additional recording fees may apply) E] Subdivision (SUB) NOTE: When multiple applications are processed concurrently the appropriate fee shall be charged for each application. ..................................................................... - ............. (.::: �2 Property Owners' List within 500' (City to generate after pre -application rnw6V) .................................................. $3 per address ( 65 addresses) Escrow for Recording Documents (check all that apply) ........................ . I. ...ff ................. ( �5r document El Conditional Use Permit El interim Use Perinti .... Site Plan Agreement El Vacation E Variance E] Wetland Alteration Permit El Metes & Bounds Subdivision (3 docs.) 0 Easements (_easements) TOTAL FEE: $870.00 Section 2: Required Information Description of Proposal: New Parking Lot where existing detention pond is located, construction of a new underground storm chamber system, and main entrancelexit drive widening. Property Address or Location Parcel # SEE ATTACHED Minnetonka West Middle School, 5421 Hazelting Blvd., Excelsior, MIN Legal Description - Total Acreage: 30.71 Wetlands Present? Present Zoning. Office and Institutional District (01) Present Land Use Designation: Select One Existing Use of Property: School 0 Check box is separate narrative is attached. SEE ATTACHED D Yes W1 No Requested Zoning: Office and Institutional District (01) Requested Land Use Designation Puhlir./Semi-Public El Create 3 lots or less ........................................ $300 El Create over 3 lots ....................... $600 + $15 per lot lots) El Metes & Bounds (2 lots) .................................. $300 El Consolidate Lots .............................................. $150 El Lot Line Adjustment. ........................................ $150 El Final Plat .......................................................... $700 (Includes $450 escrow for attorney costs)* *Additional escrow may be required for other applications through the development contract. El Vacation of Easements/Right-of-way (VAC) ........ $300 (Additional recording fees may apply) El Variance (VAR) ......... ..... - .......... ................... $200 E] Wetland Alteration Permit (WAP) El Single -Family Residence ............................... $150 ElAll Others ....................................................... $275 El Zoning Appeal ...................................................... $100 El Zoning Ordinance Amendment (ZOA) ................ � $500 NOTE: When multiple applications are processed concurrently the appropriate fee shall be charged for each application. ..................................................................... - ............. (.::: �2 Property Owners' List within 500' (City to generate after pre -application rnw6V) .................................................. $3 per address ( 65 addresses) Escrow for Recording Documents (check all that apply) ........................ . I. ...ff ................. ( �5r document El Conditional Use Permit El interim Use Perinti .... Site Plan Agreement El Vacation E Variance E] Wetland Alteration Permit El Metes & Bounds Subdivision (3 docs.) 0 Easements (_easements) TOTAL FEE: $870.00 Section 2: Required Information Description of Proposal: New Parking Lot where existing detention pond is located, construction of a new underground storm chamber system, and main entrancelexit drive widening. Property Address or Location Parcel # SEE ATTACHED Minnetonka West Middle School, 5421 Hazelting Blvd., Excelsior, MIN Legal Description - Total Acreage: 30.71 Wetlands Present? Present Zoning. Office and Institutional District (01) Present Land Use Designation: Select One Existing Use of Property: School 0 Check box is separate narrative is attached. SEE ATTACHED D Yes W1 No Requested Zoning: Office and Institutional District (01) Requested Land Use Designation Puhlir./Semi-Public Section 3: Property Owner and Applicant Information APPLICANT OTHER THAN PROPERTY OWNER: In signing this application, 1, as applicant, represent to have obtained authorization from the property owner to file this application. I agree to be bound by conditions of approval, subject only to the right to object at the hearings on the application or during the appeal period. If this application has not been signed by the property owner, I have attached separate documentation of full legal capacity to file the application. This application should be processed in my name and I am the party whom the City should contact regarding any matter pertaining to this application. I will keep myself informed of the deadlines for submission of material and the progress of this application. I further understand that additional fees may be charged for consulting fees, feasibility studies, etc. with an estimate prior to any authorization to proceed with the study. I certify that the information and exhibits submitted are true and correct. Name: Address: Contact: Phone: City/State/Zip: Cell: Email: Faxi Signature: Date PROPERTY OWNER: In signing this application, 1. as property owner, have full legal capacity to, and hereby do, authorize the filing of this application. I understand that conditions of approval are binding and agree to be bound by those conditions, subject only to the right to object at the hearings or during the appeal periods. I will keep myself informed of the deadlines for submission of material and the progress of this application. I further understand that additional fees may be charged for consulting fees, feasibility studies, etc, with an estimate prior to any authorization to proceed with the study. I certify that the information and exhibits submitted are true and correct. Name: Minnetonka Schools, ISD #276 Contact: Paul Bourgeois Address: 5621 County Road 101 Phone: (952) 401-5039 City/State/Zip: W2!�tonka, MIN 55345 Cell: (612) 240-5997 Email: KPI.bo(r�eo�4Rinnetonka.kl2'.�nn.us Fax: (952) 401-5032 Signature: Date: 9/4/15 This application must be completed in full and must be accompanied by all information and plans required by applicable City Ordinance provisions. Before filing this application, refer to the appropriate Application Checklist and confer with the Planning Department to determine the specific ordinance and applicable procedural requirements and fees. A determination of completeness of the application shall be made within 15 business days of application submittal. A written notice of application deficiencies shall be mailed to the applicant within 15 business days of application. PROJECT ENGINEER (irf applicable) Name: Address: City/State/Zip: Email: Inspec 5801 Duluth St. —Minneapolis, MIN 55422 cbuhman@inspec.com Who should receive copies of staff reports? Contact� Phone: Cell: Fax: Cliff Buhman (763) 546-3434 (952) 239-2591 (763) 546-8669 *Other Contact Information: Z Property owner Via: Z Email [_1 Mailed Paper Copy Name: Applicant Via: 0 Email E] Mailed Paper Copy Address: Engineer Via: R] Email [] Mailed Paper Copy City/State�/_Zlp_ Other* Via: D Email E] Mailed Paper Copy Email: INSTRUCTIONS TO APPLICANT: Complete all necessary form fields, then select SAVE FORM to save a copy to your device. PRINT FORM and deliver to city along with required documents and payment. SUBMIT FORM to send a digital copy to the city for processing (required). E�� E� E�i� r00110. September 3, 2015 INSPEC City of Chanhassen ciTY0FCH*lHA6SEN RECEIVED Minneapolis, MN 55422 Community Development Department Ph, 763-54&3434 Fa� 763-546-8669 Planning Division SEP 0 8 2015 7700 Market Boulevard Smart engineering of P.O. Box 147 CHANHAW PLANNING DFa Chicago Chanhassen, MN 55317 roofs, walls, windows, To Whom It May Concern: pavements On behalf of Minnetonka Schools, please find attached the Interim Use Permit (IUP) and waterproofing Application, check for $870, and the supporting required plans and documents for the proposed construction of a new parking lot at Minnetonka Middle School West. This project is in the location of the existing north detention pond to provide much needed additional parking, construction of a new underground storm chamber system to effectively manage the stormwater runoff from this drainage area, widening of the west main entrance/exit drive for improved traffic flow, and construction of new paths between the tennis courts to provide better access. The following are the amounts for the hard -surface changes: Proposed Parking Lot 0.61 acres Drive Widen 0.14 acres New Paths 0.20 acres In submitting this application for the School, I acknowledge the following for the proposed project: a. Will not be detrimental to or endanger the public health, safi*, comfort, convenience or general welfare of the neighborhood or the city. b. Will be consistent with the objectives of the city's comprehensive plan and this chapter. c. Will be designed, constructed, operated and maintained so to be compatible in appearance with the existing or intended character of the general vicinity and will not change the essential character of that area. d. Will not be hazardous or disturbing to existing or planned neighboring uses. 5801 Duluth Street e. Will be served adequately by essential public facilities and services, including Minneapolis, MN 55422 streets, police and fire protection, drainage structures, refuse disposal, water and Ph, 763-54&3434 Fa� 763-546-8669 sewer systems and schools; or will be served adequately by such facilities and services provided by the persons or agencies responsible for the establishment of the proposed use. Chicago f Will not create excessive requirements for public facilities and services and will Milwaukee not be detrimental to the economic welfare of the community. Minneapolis g. Will not involve uses, activities, processes, materials, equipment and conditions �Jnspec.com of operation that will be detrimental to any persons, property or the general welfare because of excessive production of traffic, noise, smoke, fumes, glare, odors, rodents, or trash. Minnetonka Public Schools Minnetonka Middle School West September 3, 2015 Page 2 h. Will have vehicular approaches to the property which do not create traffic congestion or interfere with traffic or surrounding public thoroughfares. Will not result in the destruction, loss or damage of solar access, natural, scenic, or historic features of major significance. Will be aesthetically compatible with the area. k. Will not depreciate surrounding property values. Will meet standards prescribed for certain uses as provided in this article. We appreciate the opportunity to work with you and look forward to another successful project. Sincerely, fNSPEC 12 / must be submitted with site plan reviews. NOTE: When multiple applications are processed, the appropriate fee shall be charged for each application. PROJECT NAME Minnetonka West Middle School- 2014 Parking Lot Addition & Stormwater Drainage Improvements LOCATION 6421 Hazelting Blvd., Chanhassen, MN LEGAL DESCRIPTION AND PID LEGAL DESCR[PTION 11it Southwest Ouarter (SW 1/4) of the Northwest Worter (NW 1/4) of section Three (3). Township One Hundred Sixterehir (116). Range Twenty Three (23) WesL according to the U. S Govemment Sur,,ey thereof. excepting therefrom the 35/100th, acres conwired by deed recorded 6n the office of the Register of Deeds of Carver County, Minnesota, in Back 8 of Deeds, page 400, and that pad thereof com,eyed by deed recorded in the office of the Register of Deeds of Carver county. Minnesota, in Book 41 of Deeds, page 322, end straject to the right, title arid Interest of the Stott of Minnesota in that strip of tend conveyed by deed recorded in the office of the Register of Deeds of Cor�er County. Minnesota, In Book 33 of Deeds. page 25� A15o that port of Let E, Bmd.ell Acres, at :oriveyed by said deed recorded in the off ct or the Register of Deeds of Carver County, Minnesota. in Book 41 of Deeds. page 322. Subject to a pernionent easement for roadway purposes as recorded in the office of the Register of Deeds of carver county. Minnesota. in Back 64 of Deeds, page 32. TOTAL ACREAGE: 30.71 WETLANDS PRESENT NO PRESENT ZONING: Office & Institutional REQUESTED ZONING No Change PRESENT LAND USE DESIGNATION. School, REQUESTED LAND USE DESIGNATION: No Change REASON FOR REQUEST FOR SITE PLAN REVIEW Include number of existing employees and new employees: This application must be completed in full and be typewritten or clearly printed and must be accompanied by all information and plans required by applicable City Ordinance provisions Before filing this application, you should confer vAth the Planning Department to determine the specific ordinance and procedural requirements applicable to your application. A cletemlination of completeness of the application shail be made within 15 business days of application submittal. A written notice of application deficiencies shall be mailed to the apiplic�ant within 15 business days of application CITY OF CHANHASSEN RECEIVED SEP U H 201b CHANHASSEN PLANNING DEPT c:) L7' C) KEYED NOTES: (D REMOVE EXISTING CURB AND GUTTER AS NEEDED FOR WIDENING OF EXISTING DRIVE. 0) REMOVE EXISTING GRASS AND SUBGRADE SOIL AS NEEDED FOR OD TIC Ll 0 ()o WIDENING OF EXISTING DRIVE. x it tD REMOVE EXISTING BITUMINOUS WALKWAY. CD 0 x 1,D" cj REMOVE EXISTING STONE/GRAVEL AND EARTHWORK AS REQUIRED. 4�1 / I I cc CD x REMOVE EXISTING FENCE. an c (JI Cil CD REMOVE ALL EXISTING TREES AND VEGETATION IN SHADED AREA Ib ------------ w N� CD FOR CONSTRUCTION ON NEW PARKING LOT. w REMOVE EXISTING GRASS, SUBGRADE SOIL AND DRAIN TILE AS NEEDED x cil Co m FOR CONSTRUCTION OF BITUMINOUS WALKWAY. C) CD DRAIN POND, COORDINATE WITH ENGINEER. EXCAVATE AS REQUIRED. x ----------- SEE GRADING AND DRAINAGE PLAN AND EXHIBIT A. _p� �:u w R) i i 1 > REMOVE EXISTING PIPE AND RIP -RAP. C-) cil CA x CD X < U1 INSTALL SILT FENCE PRIOR TO CONSTRUCTION START. n,) FT1 co PROVIDE INLET PROTECTION AT ALL CATCH BASIN/MANHOLES. CD REMOVE EXISTING CURB AND GUTTER. C) i CD W CD PLACE BIO -ROLLS ALONG ENTIRE EDGE, APPROX. 290 L.F. 00 c) x Co ROCK CONSTRUCTION ENTRANCE PER CITY OF CHANHASSEN DETAIL co cil (SEE SPECIFICATIONS) X) AFTER THE POND HAS BEEN COMPLETELY DRAINED THE CONTRACTOR SHALL CONTACT THE ENGINEER FOR SOILS ASSESSMENT. THE AMOUNT OF SOILS TO EXCAVATE WILL BE DETERMINED PROMPTLY THEREAFTER. EY THE ORIGINAL DETENTION POND WAS TO HAVE BEEN CONSTRUCTED PER THE 2003 INSPEC PLAN (SEE EXHIBIT A). CD X R) -------------- CD i THE CONTRACTOR'S BID SHALL BE BASED ON THE 2003 PLAN (EXHIBIT A) AND ------- ":IMP O'N THESE PLANS. IF ADDITIONAL EXCAVATION BEYOND WHAT WOULD BE REQUIRED U1 PER THE 2003 PLAN FINISHED ELEVATIONS, THE CONTRACTOR MUST PROMPTLY IN CONTACT THE ENGINEER AFTER BECOMING AWARE OF THIS TO DETERMINE HOW TO PROCEED AND WHAT PRICE ADJUSTMENTS ARE IN ORDER. -- --------- "71 c� CD x con co CD 0 x w 1 C-1 kD CD CA Cfl CD x x 00 KI! :4- 01 1> x C) R 41 _x 41 L6 'g ­ D --guip- �[i" Mg't AR -IN wmi_ W, _j I " - H: J-0 .. ... w /b 41 0. IU� 4m)o HA N 5 X, ci Z_ Z_ --- ----------- -------------------------------- CD --------- - - --- — -------------------- ------ v------------- ------------------------------------------------------------------------- M_ OR �:u - -------------------------- - ------ -- ------- -- -- -- -------------------- ----------- - -- FENCE CL --m ;:o z z A A CATCH BASIN/MANHOLE SCHEDULE CB/MH TYPE TOP RIM INLET FRAME INV. ELEV. INV. ELEV. # ELEV. AND GRATE IN OUT 1043.51 1 48" DIA. CONIC. 1052.40 SOLID CONTRACTOR 1043.50 MONOLITHIC TO VERIFY 1043.20 (N) 2 60" DIA. CONIC. 1053.00 SOLID 1043.05(S) 1043.00 MONOLITHIC 1048.60 (E) METAL 3 30" NYLOPLAST 1052.20 STD.CB 1049.20 1049.20 INLET 4 60" DIA. CONIC. 1051.00 SOLID 1043.80 (W) 1043.76 MONOLITHIC 1046.20 (N) 48" DIA. CONIC. NEENAH R-2573 5 1048.50 FRAME AND 1044.48 MONOLITHIC TYPE C GRATE 72" DIA. CONIC. 1043.00 (N) 6 1053.00 SOLID 1043.00 MONOLITHIC 1043.00 (W) 7 48" DIA. CONIC. 1057.50 SOLID 1043.00 1040.00 MONOLITHIC METAL 8 30" NYLOPLAST 1051.00 1 STD.CB 1048.00 1 104 8001 INLET loi , /x CD' ril I f x ;0. Cil cc) CD TOP OF CONC. 50 WEIR 1043.5 Cl) x 00 9 �M�ATCI - 1"'f CD C -__y__ C11 70 w -Z x CD xz Cw) X �D, CD Q) 4. k -------- #�' Ul� A I . . ". �D CD - --------- x LFAIST. CbRB AND GUTTE - ----- 043 12 C5 t BE REIIIIAPPROX. 290 L.F.) . . . . . . . . . . x �x --- C). CD AoA5 .0000 Cfl 1z 7/ ------ CD ------- rx �x 00 CD C5 CD_. N _N �lnAA K1. 4AAn n h =110- 0 FT] F_ CD CJ CO w- 00 045 10 46 041, 1 A4 01,9 9 x__ CD - ----- _T11 � __ /'_ - '-105a ------------ %_� ------------- ------ ---------------- V %- - ----------- %% ------- - ------------------------------ CF�rma_l - -- -------------------------------------------------- x x 7 0 0 0 CYI Cil o A EXIST. �_.'/'_\TCH BASIN/MA40LE RIM -1 050.59 EXIST. N W 6 D T I.E. - I Q47.50 Q) EXIST. S EI 18" PIPE I.E. E X_LS T. N -8 ,DTxI.E. 1046.�O) DUT. S PIPE I.E. 1046.6,0 7 0 cyl 0 C5 00 9 9 0 - ----- ----------- CYI ----------- -- - -------- r) 05Z FT1 27 z GRADING AND DRAINAGE PLAN ci� 0 10, 20' 40' NORTH 0 SCALE: 1" = 20'-0" �:u GENERAL NOTES: I CONTRACTOR RESPONSIBLE FOR LOCATING AND PROTECTING ALL PUBLIC AND PRIVATE SITE UTILITIES. CONTACT GOPHER STATE ONE CALL AND PRIVATE LOCATOR PRIOR TO PERFORMING ANY WORK. CONTRACTOR IS RESPONSIBLE FOR REPAIRING AND RESTORING ANY DAMAGED PROPERTY. 2. ALL CONSTRUCTION MUST COMPLY WITH APPLICABLE CODES AND ORDINANCES. 3. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL CONSTRUCTION PERMITS AND CONSTRUCTION STAKING. 4. PROTECT EXISTING FACILITIES, UTILITIES, TREES, AND VEGETATION WHICH ARE TO REMAIN. RESTORE ALL DISTURBED AREAS, INCLUDING PAVEMENTS, LANDSCAPING, AND LAWN AREAS TO ORIGINAL CONDITION. 5. SWEEP SITE PAVEMENTS AND ADJACENT STREETS AT CONSTRUCTION VEHICLE ACCESS POINTS AT COMPLETION OF PROJECT. 6. ALL DIMENSIONS ANDI QUANTITIES ARE APPROXIMATIONS. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING. 7. CONTRACTOR TO RESTRIPE ALL PARKING LOTS AND DRIVES ON CAMPUS UPON COMPLETION OF PROJECT TO ORIGINAL CONDITIONS, INCLUDING BUT NOT LIMITED TO PARKING SPACES, CURBING, AND OTHER EXISTING DEMARCATION. 8. PROPERLY RE -INSTALL ALL SIGNS AND FENCE REQUIRED TO BE REMOVED AFTER COMPLETION OF PAVEMENT REHABILITATION. 9. FINISH GRADE SHALL BE ADJUSTED TO ACHIEVE POSITIVE DRAINAGE WITH MINIMUM SLOPE OF 1% OR MORE. 10. 'IN" DENOTES NEW FINISHED GRADEfTOP OF PAVEMENT CONTOURS ALL OTHER ELEVATIONS ARE EXISTING UNLESS NOTED OTHERWISE. 11. 0 INDICATES TOP OF FINISHED GRADE SPOT ELEVATIONS. KEYED NOTES: NEW 48" DIA. CONCRETE MONOLITHIC CATCH BASIN/MANHOLE #11. NEW 60" DIA. CONCRETE MONOLITHIC CATCH BASIN/MANHOLE #2. NEW 30" DIA. NYLOPLAST CATCH BASIN/MANHOLE #3. NEW 48" DIA. CONCRETE MONOLITHIC CATCH BASINIMANHOLE #4. NEW 48" DIA. CONCRETE MONOLITHIC CATCH BASINIMANIHOLE #5. Q NEW 72" DIA. CONCRETE MONOLITHIC CATCH BASIN/MANHOLE #15. NEW 48" DIA. CONCRETE MONOLITHIC CATCH BASIN/MANHOLE #7. NEW 30" DIA. NYLOPLAST CATCH BASIN/MANHOLE #8. NEW 18" DIA. HDPE PIPE, (APPROX. 20 L.F. TOTAL) NEW 24" DIA. HDPE PIPE, (APPROX. 110 L.F. TOTAL) NEW 30" DIA. HDPE PIPE. (APPROX. 90 L.F. TOTAL) NEW UNDERGROUND STORM CHAMBERS. (SEE STORM CHAMBERS PLAN- C4) NEW 30" HDPE MANIFOLD PIPES (APPROX. 225 L.F. TOTAL). NEW 6"DIA. HDPE PERFORATED PIPE IN SOCK, APPROX, 150 L.F. TOTAL, SLOPE 0.5% TO NEW CATCH BASIN/MANHOLE. NEW 12" DIA. HDPE PIPE, APPROX. 135 L.F. Ig TRANSITION FROM SURMOUNTABLE CURB TO 136-118 CURB AND GUTTER. 0 NEW B6-118 CONCRETE CURB AND GUTTER. �5 NEW SURMOUNTABLE CURB. 45 NEW 8" DIA HDPE PIPE, APPROX. 90 L.F. 0 NEW BITUMINOUS PATH (SHADED). go� ------------- - C -D Cil 4� 77777' ---------- 2. N 1052.4 N < . . . . . . . . . . . . . . _7 CYI ------------- 00 ----- ---- ------------ --- - --- C11 F -- --------- 00, ------------- ---- - -- -4 057 NL� �71;000r' J- Z: - ____ - I ------ --------- - ---- -- < --I uots N� ------ 1�00 If'I 7 0 - --- Fri ------------ --4053 ---- --- ------------- ---q 0Z --q 059 N� --- ----- - ------ --- - --- -------- -------- LJ_ -- -------- J0 -7j _7� 954 X� ------------- ........ .. -7- a Wilma'' C5 060 N4� 7!!� 77---!7 0.30 E E A 1061.3 F7 A :m NEW z BITUMINOUS PATH 1nR AA F 1 .4 (SHADED) A x 5801 Duluth Street Minneapolis, MN 55422 Ph. 763-546-3434 INSPEC &) 2015 Consultants: Signature: Issues and revisions: ISSUE LEVEL / REVISION: DATE: No.. Client: MINNETONKA SCHOOLS WEST MIDDLE SCHOOL Project title 2016 STORM DRAIN IMPROVEMENTS AND PARKING LOT ADDITION 6421 HAZELTINE BOULEVARD EXCELSIOR, MINNESOTA 55331 Sheet content: GRADING AND DRAINAGE PLAN DATE: 9-1-15 CLIENT PROJECT No.: INSPEC PROJECT No.: PROJECT MGR: CB DRAWN BY: 13T CHECKED BY: BB Sheet No. C2 Ln I Cb cl) F- 0 –i 3: z Lb z Lu EL 0 Q cc 0 Mn z C < 0 > (a m EL 2 < LL 2 75- 02 I — I - . 27' 2 :S1 5 3 163-25' 3 Ile r� P-4 91 41� 5 3 TCH LINE 5 C5 24' 13 2 C5 5 1� LAYOUT PLAN C5 C5 0 10, 20' 40' ZW- 5 NORTH 4 C5 C5 SCALE: 1 20'-0" 10 C5 164' 9 5801 Duluth Street Minneapolis, MIN 55422 tool". Ph. 763-546-3434 INSPEC (9) 2015 Consultants: Signature: Issues and revisions: ISSUE LEVEL/ REVISION: DATE: No.: Client: MINNETONKA SCHOOLS WEST MIDDLE SCHOOL Project title: 2016 STORM DRAIN IMPROVEMENTS AND PARKING LOT ADDITION 6421 HAZELTINE BOULEVARD EXCELSIOR, MINNESOTA 55331 Sheet content: LAYOUT PLAN DATE: 9-1-15 CLIENT PROJECT No.: INSPEC PROJECT No.: PROJECT MGR: CB DRAWN BY: BT CHECKED BY: 1313 Sheet No.: C3 GENERAL NOTES ALL DESIGN SPECIFICATIONS FOR THE STORM WATER CHAMBERS SHALL BE IN ACCORDANCE WITH THE MANUFACTURERS DESIGN SPECIFICATIONS. THE CONTRACTOR IS ADVISED TO REVIEW AND UB=NDERSDTAND THE INSTALLATION REQUIREMENTS PRIOR TO BEGINNING SYSTEM INSTALLATION. CHAMBERS SHALL MEET THE DESIGN REQUIREMENTS AND LOAD FACTORS SPECIFIED IN SECTION 12.12 OF THE LATEST EDITION OF THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS. CHAMBER SHALL MEET ASTM F 2418-05 "STANDARD SPECIFICATION FOR POLYPROPYLENE �CORRUGATED WALL STORMWATER OPIECTION CHAMBERS". 3/4 - 2 INCH CLEAN ANGULAR AASHTO M288 CLASS 2 NON -WOVEN GEOTEXTLE STONE 1045.50 1040.50 NEW 4" BITUMINOUS PAVEMENT OVER 8" BASE AGGREGATE MC -4500 CHAMI TO OUTLET CONTROL STRUCTURE 18" OUTLET PIPE INV- 1D43_00 SECTION 3-8 SECTION A -A OUTLET ELEVATIONS NO SCALE STORMTE ISOLATOF -GRANULAR WELL GRADED SOIL AGGREGATE MIXTURES, �57 1 IN 6" LIFTS CT6 F NES. C TO 95% PR R DENSITY. SEE THE TABLE OF ACCEPTABLE FILL MATERIALS, AS REQUIRED (SEE GRADING AND DRAINAGE PLAN) NEW 30" OMP/ CT HOPE DW PIPE TOP OF SC -740 GRADE END CAP THIS CROSS SECTION DETAILS THE REQUIREMENTS NECESSARY TO SATISFY THE LOAD FACTORS SPECIFIED INTHE AASHTO _RFD BRIDGE DESIGN SPECIFICATIONS SECT10N 12.12 FOR EARTH AND LIVE LOADS WITH CONSIDERATION FOR IMPACT AND MULTIPLE VRHICLE PRESENCES. STANDARD MC -4500 CROSS SECTI ON NO SCALE < < NEW 72- (MH MANHOLE OVERFL WEIR NEW 30" HOPE DW MC -4500 30" INLET PIPE INV. = 1043.00 30" MANIFOLD INV. 1043.00 MC -4500 CHAMBER LAYOUT NO SCALE SEE GRADING AND DRAINAGE PLAN, SHEET C-2 "'ACE MINIMUM 12.5' OF AASHTO '88 CLASS 1 WOVEN GEOTEXTILE ER BEDDING STONE FOR SCOUR OTECTIONAT ALL CHAMBER INLET WS B0170M OF CHAMBERS- ELEV. = 1040.50 BOTTOM OF FOUNDATION STONE ELEV. 1039.00 TOP OF GRADE ELEV. APPROX. 956.00 30" HOPE DIN PIPE (TYP. 4 LOCATIONS) 130TTOM MI -L 1041.00 INV. ELEV. 41 777 30" MANIFOLD PIPE B INV. ELEV. = 1043.00 ---,\INLET ELEVATIONS 4 NO SCALE PROPOSED LAYOUT (496 STORMTECH MC -4500 CHAMBERS INSTLILED WITH 6" COVER STONE, 18" BASE STONE, 40% STONE VOID INSTALLED SYSTEM VOLUME (PERIMETER STONE INCLUDED) 85,586.5 CIF A -A COVER ENTIRE ROW WITH AASHTO CLASS 2 NON -WOVEN GEOTEXT1LE OR EQUAL SC -740: 8' WIDE STRIP FABRICATED END CAP FOR 30" INLET PIPE STORMTECH ISOLATOR ROW FABRICATEC END CAP 30" PIPE INTO ISOLATOR ROW AND ALL CHAMBERS PIPE INV. 947.70 SOLATOR ROW NO SCALE MANHOLE OVERFLOW ECCENTF HEADER PLACE MINIMUM 12.5' AASHTO M288 CLASS WOVEN GEOTEXTILE 0 BEDDING STONE FOR PROTECTION AT ALL INLET ROWS. mc - END TM PROFILE VIEW ORMTECH DILATOR ROW MC -4500 CHAMBERS TIM ISOLATOR ROW MANIFOLD NO SCALE ACCEPTABLE FILL MATERIALS: STORM WATER CHAMBER SYSTEMS STORM NO SCALE PLEASE NOTE: THE USTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN, ANGULAR. FOR EXAMPLE, THE STONE MUST BE SPECIFIED AS CLEAN, CRUSHED, ANGULAR NO. 4 STONE. STORMTECH RECOMMENDS HARDNESS AND DURABILITY CRITERIA FOR USE OF RECYCLED CONCRETE IN A AND B LOCATIONS. WATER CHAMBERS ACCEPTABLE MATERIALS 5801 Duluth Street Nnneapolls, MN 55422 Ph. 763-546-3434 INSPEC 2015 Signature: Issues and revisions: ISSUE LEVEL REVISION: DATE: No.: Client: MINNETONKA SCHOOLS WEST MIDDLE SCHOOL Project title: 2016 STORM DRAIN IMPROVEMENTS AND PARKING LOT ADDITION 6421 HAZELTINE BOULEVARD EXCELSIOR, MINNESOTA 55331 Sheet content STORM CHAMBER DETAILS DATE: 9-1-15 CLIENT PROJECT No.: INSPEC PROJECT No.: PROJECT MGR: CB DRAWN BY: BT CHECKED BY: BB DESCRIPTION AASHTO M43 AASHTO M145 COMPACTION/DENSITY MATERIAL LOCATION DESIGNATION DESIGNATION REQUIREMENT ANY SOIL/ROCK MATERIALS, NATWE FILL MATERIAL FROM 18" TO SOILS OR PER ENGINEER'S PLANS. N/A N/A PREPARE PER SPECIFICATIONS. GRADE ABOVE CHAMBERS CHECK PLANS FOR PAVEMENT SUBGRADE REQUIREMENTS. 3. 357, 4, 467, COMPACT IN 6" LIFTS TO A MINIMUM 95% FILL MATERIAL FOR 6" TO GRANULAR WELL -GRADED SOIL/AGGREGATE 5, 56, 57, 6,67, A -I STANDARD PROCTOR DENSITY. ROI I FIR GROSS 18' ELEVATION ABOVE CHAMBERS MIXTURES, < 35% FINES. 68, 7, 78, 8, 89, A-2 VEHICLE WEIGHT NOT TO EXCEED 12,000 LBS. (24- FOR UNPAVED INSTALLATIONS) 9. 10 A-3 DYNAMIC FORCE NOT TO EXCEED 20,000 LBS. EMBEDMENT STONE SURROUNDING CLEAN ANGULAR STONE NTH THE MAJORITY 3, 357, 4. 4,57, AND TO A MIN. 6" ELEVATION OF PARTICLES BETWEEN 3/4 - 2 INCH 5. N/A NO COMPACTION REQUIRED. ABOVE CHAMBERS INCH 56, 57 CLEAN ANGULAR STONE NTH THE MAJORITY 3, 35, 4, 467, PLATE COMPACT OR ROLL TO ACHIEVE A 95% FOUNDATION STONE BELOW CHAMBERS OF PARTICLES BETWEEN 3/4 - 2 INCH 5. N/A STANDARD PROCTOR DENSITY. INCH 56, 57 STORM NO SCALE PLEASE NOTE: THE USTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN, ANGULAR. FOR EXAMPLE, THE STONE MUST BE SPECIFIED AS CLEAN, CRUSHED, ANGULAR NO. 4 STONE. STORMTECH RECOMMENDS HARDNESS AND DURABILITY CRITERIA FOR USE OF RECYCLED CONCRETE IN A AND B LOCATIONS. WATER CHAMBERS ACCEPTABLE MATERIALS 5801 Duluth Street Nnneapolls, MN 55422 Ph. 763-546-3434 INSPEC 2015 Signature: Issues and revisions: ISSUE LEVEL REVISION: DATE: No.: Client: MINNETONKA SCHOOLS WEST MIDDLE SCHOOL Project title: 2016 STORM DRAIN IMPROVEMENTS AND PARKING LOT ADDITION 6421 HAZELTINE BOULEVARD EXCELSIOR, MINNESOTA 55331 Sheet content STORM CHAMBER DETAILS DATE: 9-1-15 CLIENT PROJECT No.: INSPEC PROJECT No.: PROJECT MGR: CB DRAWN BY: BT CHECKED BY: BB BITUMINOUS PAVEMENT DETAIL NO SCALE ADJUSTING RINGS AS NEEDED (4" MINIMU 12" MAXIMUM) STEPS 16" ON CENTER ON DOWNSTREAM SIDE Ab KI=UUIKIzU NEW 4" BITUMINOUS PAVEMENT PLACED IN TWO LIFTS NEW 8" COMPACTED CLASS V BASE AGGREGATE EXISTING SUBGRADE SOIL OR BACKFILL TO TO BE GRADED AND COMPACTED PRECAST REINFORCED CONE AND RISER SECTIONS CONFORMING TO ASTM C478. PROVIDE TOP SLAB WHERE TOTAL BUILD DEPTH DOES NOT ACCOMMODATE CONE SECTION JOINTS BETWEEN PRECAST SECTIONS SHALL USE O-RING RUBBER GASKETS CONFORMING TO ASTM C443 Ld (03 NEW w NEW PIPE of PIPE FLOW NEW 6" PRECAST CONCRETE U) BASE SLAB —EXIST. SUBGRADE SOILS AS REQUIRED TO BE COMPACTED -IL ::i'� CATCH BASIN/MANHOLE DETAIL NO SCALE Cb 0 _J 3: Lu 0 I CONTROL—\ T BLANKET AND SEED NEW PLANT MEDIUM WITH A WELL BLENDED MIXTURE OF 30% WASHED SAND (AASHTO M-6 OR ASTM C-33),35% PULVERIVED HYPNUM PEAT OR LEAF LITTER COMPOST (MNDOT GRADE 2), AND 35% PULVERIZED TOPSOIL TOP OF GRADE ELEVATIONS PER GRADING PLAN SEED TO BE MNDOT 25-141 TAT 59ff PER ACRE AT BOTTOM OF CELL ALL OTHER AREAS TO BE SEEDED WITH MNDOT 25-121 AT 61# PER ACRE ?LTYP. 1 BACKFILL WITH NEW TOPSOIL AND SEED (MNDOT 25-121 AT 61#1ACRE AT ALL DISTURBED AREAS 1/2" PREFORMED CLOSED CELL ISOLATION JOINT MATERIAL NO SCALE Nr z z 04 BACKFILL WITH NEW TOPSOIL AND SEED (MNDOT 26-121 AT 61#1ACRE AT ALL DISTURBED AREAS 12" BACKFILL WITH NEW TOPSOIL AND SEED (MNDOT 26-121 AT 61#/ACRE AT ALL DISTURBED AREAS 1, 12" SURMOUNTABLE INPUT CONCRETE CURB DETAIL NO SCALE OF PIPE B r7 EDDING DETAIL I NO SCALE TAPERED CL BACKFILL MATERIAL SHALL E BE CRUSHED STONE OR GRAVEL MATERIAL MEETING CLASS 1 OR 2 AS SPECIFIED IN ASTM D2321, BACKFILL MATERIAL SHALL BE PLACED 0 UNIFORMIALLY IN 12" LIFTS ULI AND COMPACTED. NYLOPLAST MANHOLE (2) AND CATCH BASIN DETAIL C5 NO SCALE (SEE GRADING PLAN) Nr z z 04 BACKFILL WITH NEW TOPSOIL AND SEED (MNDOT 26-121 AT 61#1ACRE AT ALL DISTURBED AREAS 12" BACKFILL WITH NEW TOPSOIL AND SEED (MNDOT 26-121 AT 61#/ACRE AT ALL DISTURBED AREAS 1, 12" SURMOUNTABLE INPUT CONCRETE CURB DETAIL NO SCALE OF PIPE B r7 EDDING DETAIL I NO SCALE TAPERED CL UNDERDRAIN GRAVEL BLANKET CONSISTING OF 1"-1.6" E DOUBLE WASHED STONE OR 1/4" TO 1/2" WASHED RIVER RUN PEA GRAVEL. MINIMUM OF 3" ABOVE AND BELOW PIPE, WRAPPED IN NOTE: NEW 6 -PERF NON -WOVEN GEOTEXTILE FABRIC 0 OTTOM OF FILTRATION CELL SHALL RIPPEDIAERATED TO A B HDPE PIPE, SLOPED ULI MINIMUM DEPTH OF 24" AND SHALL BE APPROVED BY 0.5% TO NEW OUTLET 0 ENGINEER BEFORE FINAL GRADING AND LANDSCAPING STRUCTURE V5 z U) NEW FILTRATION CELL DETAIL NO SCALE 0 ILL w SOLID LID >_ a- 0 0 Z; NEW SAFL BAFFLE TO BE STEPS 16" D.C. INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS -7— C) NEW CU CONCRETE WEIR NEW NEW INLET OU TUET PIPE PIPE 4(-- W a NEW 2" DIA. NEW NON–WOVEN GEOTEXTILE FABRIC, HOLE THROUGH & PROVIDE 12" OVERLAP BASE BOTH SIDES 0 NEW 8 3/4" PLUS CLEAR LIMESTONE CD WRAPPEDIN NEW E AASHTO M288 CLASS 2 NON–WOVEN GEOTEXTILE AS REQUIRED FABRIC a- NEW MANHOLE #6 DETAIL WITH WEIR AND SAFL BAFFLE 1/2" THICK---/ BITUMINOUSJ PREFORMED JOINTCONCRETE CURB AND— PAVEMENT MATERIAL GUTTER IBLE RAMP ISO. io ACCESS NO SCALE AND PROPERLY COMPACTED PRIOR TO PLACEMENT OF NEW MATERIALS FINAL SUBGRADE COMPACTED BACKFILL EXISTING SUBGRADE SOIL COMPACTED SAND CONFORMING TO MN/DOT 3149 —NEW STORM SEWER PIPE NOTE: 1) TRENCHING TO MEET O.S.H.A. REQUIREMENTS. TIE THE LAST 6 JOINTS ON INLET PIPE AND BED IN GRANULAR MATERIAL. USE 2 TIE BOLT FASTENERS PER JOINT INSTALLED AT 60 DEG FROM TOP OR BOTTOM OF PIPE. USE 6/8" TIE FOR PIPE SIZES 12" TO 27" SEE DETAIL 6/C2 FOR RIP RAP DETAIL SURMOUNTABLE OUTPUT r4"� CONCRETE CURB DETAIL NO SCALE BACKFILL AND COMPACT IDIRT IN THE 6"X6" TRENCH AFTER INSERTING STAPLES THROUGH MATERIAL AS AN ALTERNATIVE TO TRENCHING WHEN TOP OF SLOPE IS RELATIVELY FLAT, EXTEND MATERIAL APPROXIMATELY 40" ON TOP OF INSERT STAPLES THROUGH THE MATERIAL APPROXIMATELY 20" APART 1�1 THE GROUND AND RANDOMLY BLANKET MATERIAL MUST— OVERLAP AT LEAST 6" AND STAPLES INSERTED THROUGH BOTH FABRICS AT A MAXIMUM SPACING OF 40" BLANKET MATERIAL MUST— OVERLAP AT LEAST 6" AND STAPLES INSERTED THROUGH BOTH FABRICS AT A MAXIMUM SPACING OF 20" APART NEW BITUMINOUS PAVEMENT NEW PORTLAND CEMENT CONCRETE (DURACRETE OR APPROVED EQUAL) NEW CLASS V BASE AGGREGATE SUBGRADE SOIL TO BE GRADED AND PROPERLY COMPACTED PRIOR TO PLACEMENT OF NEW MATERIALS NOTES: INSERT STAPLES THROUGH THE BLANKET IN A 6"X6" TRENCH WITH EACH PATTERN OF 3 STAPLES APPROX. 20" APART. MAXIMUM STAPLE SPACING, STAPLES MUST BE INSERTED THROUGH OVERLAP MATERIAL. &7 4 f 777 CATEGORY3 EROSION CONTROL BLANKET --------AT END OF SLOPE, SECURE BLANKET MATERIAL BY INSERTING STAPLES APPROXIMATELY 20" APART THROUGH THE FABRIC A NOTES: 1 . HAND PLACE GRANITE RIPRAP AROUND SIDES AND OVER TOP OF F.E.S. 2. PLACE NONWOVEN GEOTEXTILE FABRIC UNDER RIPRAP AND EXTENDING 1'UNDER F.E.S. 3. INDIVIDUAL STONES SHALL NOT WEIGH LESS THAN 50 POUNDS EACH EXCEPT THOSE USED FOR CHINKING. MIN. BARS BOLTS 'U 11. 3/4" 6"MAX U' INSTALL 3 HOT DIP GALVANIZED CLIPS TO FASTEN TRASH GUARD TO F.E.S. FLARED END WITH TRASH GUARD NO SCALE IUM 6 C.Y. CLASS %NITE RIPRAP THE APRON HER THAN T. =XTII F FARRIC EXTEND 1'UNDER FES RIPRAP AT FLARED END DETAIL NO SCALE 5801 DUluth Street Minneapolis, MN 55422 t0000. Ph. 763-546-3434 INSPEC (9) 2015 Consultants: Signature: Issues and revisions: ISSUE LEVEL I REVISION: DATE: No.: Client: MINNETONKA SCHOOLS WEST MIDDLE SCHOOL Project title: 2016 STORM DRAIN IMPROVEMENTS AND PARKING LOT ADDITION 6421 HAZELTINE BOULEVARD EXCELSIOR, MINNESOTA 56331 eet content DETAILS DATE: 9-1-15 CLIENT PROJECT No.: INSPEC PROJECT No.: PROJECT MGR: CB DRAWN BY: BT CHECKED BY: BIB Sheet No.: C5 TC IV 0 L/ ME LE POND OUTLET CONTROL STRUCTU WITH TRASH 6UARD (65E DETAIL 4/W Vr 4y 1 4— :- I - -S�� 1� 1 fin I Amap r—A I r�H NOT USW NOT USED f-ROVIDE FLAREP END AITW TRASH GUARD AND PLACE Rif=-RAf= OVER FILTER FA5RJC- I(SEE DETAILS 11/4 8 12/4; NEN Sump CATCH BASIN. SEE DETAIL 2/5 AND CATCH BASIN SCHEDULE. INSTALL DRAJNT14E BELON SUBGRADE AND DRAIN TO NEH CATCH BASINS. RELOCATED FLAG POLE AIL NOTES 1� verify measurements and conditions on the project, 1. Shaded portion on key and site plan represent existing buildings, 2, specifications Include brief descriptions of existing conditions. 3. Review specifications for Instructions not shown on drawings. 4. Existing and neW materials Common to several details may be noted on only one. 5- Shaded portions on details represent existing conditions. 5� Review project specifications for additional details not shown On drawings, 7. Contractor shall be responsible for maintaining safe working conditions on areas for employees or other persons at the site. �Wfta um- �ETAIL SYMBMS HEMY CERTIFY TKOLT THIS PLAN. %nCIFICAIM& OR RVORT WU MEW= By NE M IAI� my Dam VaIMAX I AM A I 2003 PAVEMENT REHABILITATION 4NSPEC, INC. 1! 71 Existing/ EXiStlng/ New soil Now concrete DUFMCIMIUM UNDER THE LA: E MWESOTA, MINNETONKA MIDDLE SCHOOL WEST 58 1 Juir ir Im Existing/New AIL NOTES 1� verify measurements and conditions on the project, 1. Shaded portion on key and site plan represent existing buildings, 2, specifications Include brief descriptions of existing conditions. 3. Review specifications for Instructions not shown on drawings. 4. Existing and neW materials Common to several details may be noted on only one. 5- Shaded portions on details represent existing conditions. 5� Review project specifications for additional details not shown On drawings, 7. Contractor shall be responsible for maintaining safe working conditions on areas for employees or other persons at the site. �Wfta um- �ETAIL SYMBMS HEMY CERTIFY TKOLT THIS PLAN. %nCIFICAIM& OR RVORT WU MEW= By NE M IAI� my Dam VaIMAX I AM A I 2003 PAVEMENT REHABILITATION 4NSPEC, INC. 1! 71 Existing/ EXiStlng/ New soil Now concrete DUFMCIMIUM UNDER THE LA: E MWESOTA, MINNETONKA MIDDLE SCHOOL WEST 58 1 Juir ir Minneapoiis. W 55422 (763) 546-3434 Existing/New MINNETONKA PUBLIC SCHOOLS C2002 base aggregate Existing/New CHANHASSEN, MINNESOTA PROJ. MGR mR DFL eT 11 bituininOLS pavement ;Jrj&s� PA0J. NO. 204-7w CK. SL 'I MINTua , , "� �'j D 4 -TE! Generous, Bob From: Scheffing, Karen (DOT) < Karen.Scheffi ng @state. m n. us> Sent: Wednesday, September 23, 2015 10:24 AM To: Meuwissen, Kim; Generous, Bob Cc: Sherman, Tod (DOT) Subject: RE: City of Chanhassen Agency Review Request for 6421 Hazeltine Boulevard (Minnetonka Middle School West) Interim Use Permit Kim and Bob MnD0T has reviewed the proposed development proposal for the Minnetonka Schools and has no comments at this time. Please contact me if you have any questions. Thanks Karen Karen Scheffing Principal Planner Minnesota Department of Transportation 1500 W County Road B2 Roseville MN 55113 651-234-7784 From: Meuwissen, Kim [mailto:kmeuwissen@ci.chanhassen.mn.us] Sent: Thursday, September 10, 2015 4:12 PM To: 'chentges@co.carver.mn.us'; Sherman, Tod (DOT); 'Becky Christopher' Cc: Generous, Bob; Mohn, Jerry; Fauske, Alyson; Littfin, Mark; Sinclair, Jill; Hoffman, Todd; Jeffery, Terry Subject: City of Chanhassen Agency Review Request for 6421 Hazeltine Boulevard (Minnetonka Middle School West) Interim Use Permit Development Plan Review Agencies: Please review the attached request and respond with your comments no later than Thursday, September 24, 2015 to: Bob Generous, Senior Planner City of Chanhassen PO Box 147 Chanhassen, MN 55317 952-227-1131 bgenerous@ci.chanhassen.mn.us Replies to this email will be automatically copied to Bob. You can view the project web page that includes a link to the project documents at http://www.ci.chanhassen.mn.us/2015-23. Thank you! CITY OF CHANHASSEN CARVER & HENNEPIN COUNTIES NOTICE OF PUBLIC HEARING PLANNING CASE NO. 2015-23 NOTICE IS HEREBY GIVEN that the Chanhassen Planning Commission will hold a public hearing on Tuesday, October 6, 2015, at 7:00 p.m. in the Council Chambers in Chanhassen City Hall, 7700 Market Blvd. The purpose of this hearing is to consider a request for an Interim Use Permit to permit site grading to construct a parking lot and an underground storm chamber system, widen the main entrmce/exit driveway, and construct new paths between the tennis courts at Minnetonka Middle School West. The property is zoned Office and Institutional District (01) and located at 6421 Hazeltine Boulevard. Applicant/Owner: Minnetonka Schools, ISD #276. A plan showing the location of the proposal is available for public review on the City's web site at www.ci.chanhasserLmn.us/2015-23 or at City Hall during regular business hours- All interested persons are invited to attend this public hearing and express their opinions with respect to this proposal. Robert Generous, AICP, Senior Planner Email: bgencrous(a)ci.chanhassen.mn.us Phone: 952-227-1131 (Publish in the Chanhassen Villager on September 24, 2015) SCANNED Property Card Parcel ID Number 250033000 Taxpayer Information 7 7 j k L A"S Taxpayer Name IND SCHOOL DIST 276 Mailing Address 5621 COUNTY ROAD 101 MINNETONKA, MIN 55345-4214 Property Address Address 6421 HAZELTINE BLVD City EXCELSIOR. MIN 55331 Parcel Information Uses Schools -Public GISAcres 30.62 NetAcres 30-62 Deeded Acres 30.71 Plat Lot Block TaxDescription IN SWI/4 NW1/4AS SURVEYED Building Information Building Style =rSade Ft Bedrooms Year Built Garage N Bathrooms Miscellaneous information School District 0276 Watershed District WS 062 MINNEHAHA CREEK Homestead N Green Acres N Ag Preserve N Assessor Information Estimated Market Value 2014 Values (Payable 2015) 2015 Values (Payable 2016) Last Sale Land $3,348.000.00 $3,348,000.00 Date of Sale Building $13,809,500.00 $13,385,300.00 Sale Value Total $17,157,500.00 $16,733,300.00 1 i '] , 'ev. " " to ofeence dint, This data s hot sulable for label engineering sumeying a other simAar purposes Carver County does not guarantee the accuracy of the Womation corearned herein. This data a f.,,Sh.d on an a a basis and Carver County makes no representations or warranties either expressed or implied for the merchantability or fitness of the information provided for my purpose This disclamer is devoted pursuant to Minnesota Statutes §,166.03 and the user of the data provided dared acledowledass that Cahrer County snall not be hable for any damages and by usm this data n any way exWeest, wames all claims and agrees to defendl indemnify and hold le county � officials offrears agents em,ployees etc from any and all claim s brought by anyone who uses the information provided for herem its em,ployeea or agents or CARVER third barhes which arise drift of users accass By acceptance of this data the user agrees not to luinsmit this data or provide access to it a any part of it to another party unless the user includes COUNTy with the data a copy of this disclaimer Thursday, September 10, 2015 SCANNED Carver County, MIN Property Card Taxpayer Information Taxpayer Name IND SCHOOL DIST 276 Mailing Address 5621 COUNTY ROAD 101 MINNETONKA, MIN 55345-4214 Property Address Address 6421 HAZELTINE BLVD city EXCELSIOR, MINI 55331 Parcel ID Number 250033000 - CHANHASSEt I �'tTy 01 RECEIVEI) 2015 r 'HAt4j4ASSEmPLAN%1%30F9T Parcel Information Uses Schools -Public GIS Acres 30.62 Tax Acres 30.71 Plat Lot Block Tax Description IN SWIM NW1/4 AS SURVEYED Building Information Building Style Finished Sq Ft Bedrooms Year Built Other Garage N Bathrooms Miscellaneous information School District Watershed District Homestead Green Acres Ag Preserve 0276 WS 062 MINNEHAHA CREEK N N N Assessor Information Estimated Market Value 2012 Values 2013 Values (Payable2013) (Payable 2014) Last Sale Land $3,348,000.00 $3,348,000.00 Date of Sale Building $10,310.900.00 $12,683,100.00 Sale Value Total $13,658,900.00 $16.031,100.00 Qualified/ Unqualified D�sclanrer This nfuraahm 19 to be usm for reference purposes only, Caner County acres not guarantee, acci�cy of me material contained herern and is not responsib;a, far misuse or rnsaterpreration The tirsilardn'it) disclairater is Provided �uriivanl to urrinasow Statute, 466 03. SL'bd. 2112000), am! the user of thui service acknovilixights that the County shall not be liable for any dOntay&S and axPresslY ""s Alt claim and agreas to derem. indemnify, am hold hanniess the County from my am all claims bro�ghl by User CARVf-It its empkyees or agerts or third ORMas which arsw OX of the uws access W USP at date Provided. COLNT-Y Tuesday, November 26, 2013 CaNer County, MN Page I of I Project Information Calculator Version: Version 2: June 2014 Project Name: MMW Existing North Detention Pond User Name / Company Name: Cliff Buhman/Inspec Date: 9-5-15 Project Description: Existing North Detention Pond constructed in 2003 Site Information B Soils C Soils D Soils ciTY0KHANHASSEM (acres) (acres) (acres) (acres) FISCEIVED Retention Requirement (inches): 1.1 SEP 0 8 2015 Site's Zip Code: 55331 Annual Rainfall (inches): 29,6 10.74 Phosphorus EMC (mg/1): 0.3 CHANHASSEN PLANNING DEPT TSS EMC (mgA): S4.5 3-65 Total Site Area Total Area (acres) 14.39 Land Cover A Soils B Soils C Soils D Soils Total (acres) (acres) (acres) (acres) (acres) Forest/Open Space - Undisturbed, protected 0 forest/open space or reforested land Managed Turf - disturbed, graded for yards or 10.74 10.74 other turf to be mowed/managed Impervious Area (acres) 3-65 Total Area (acres) 14.39 Site Areas Routed to BMPs Land Cover A Soils B Soils C Soils D Soils Total (acres) (acres) (acres) (acres) (acres) Forest/Open Space - Undisturbed, protected 0 forest/open space or reforested land Managed Turf - disturbed, graded for yards or 10.74 10.74 other turf to be mowed/managed Impervious Area (acres) 3.65 Total Area (acres) 14.39 ScANNEC Summary Information Performance Goal Requirement Performance goal volume retention requirement 14574 M Volume removed by BMPs towards performance goal: ft3 Percent volume removed towards performance goal % Annual Volume and Pollutant Load Reductions Post development annual runoff volume 13.6586 acre -ft Annual runoff volume removed by BMPs: 0 acre -ft Percent annual runoff volume removed: 0 % Post development annual particulate P load: 6.13 lbs Annual particulate P removed by BMPs: 3.8 lbs; Post development annual dissolved P load: 5.02 lbs Annual dissolved P removed by BMPs: 0 lbs Percent annual total phosphorus removed: 34 % Post development annual TSS load: 2025 lbs Annual TSS removed by BMPs: 1215 lbs Percent annual TSS removed: 60 % BMP Summary Performance Goal Summary BMP Volume Volume Volume Volume Percent BMP Name Capacity Recieved Retained Outflow Retained (ft3) (ft3) (ft3) (ft3) M 1 - Constructed stormwater pond 0 14574 0 14574 0 Annual Volume Summary Particulate Phosphorus Summary Load From Volume Load Outflow Volume From Volume Volume Percent BMP Name From Direct Upstream Retained Outflow Retained Retained Watershed BMPs (acre -ft) (acre -ft) M (lbs) (acre -ft) (acre -ft) (0/.) 1 - Constructed stormwater pond 13.6586 0 0 13.6S86 0 Particulate Phosphorus Summary Load From Load From Load Outflow Percent BMP Name Direct Upstream Retained Load Retained Watershed BMPs (lbs) (lbs) (0/.) (lbs) (lbs) 1 - Constructed stormwater pond 6.13 0 3.8 2.33 62 Dissolved Phosphorus Summary Load From Load From Load Outflow Percent BMP Name Direct Upstream Retained Load Retained Watershed BMPs (lbs) (lbs) M (lbs) (lbs) (lbs) 1 - Constructed stormwater pond 5.02 0 0 5.02 0 TSS Summary Load From Load From Load Outflow Percent BMP Name Direct Upstream Retained Load Retained Watershed BMPs (lbs) (Ibs) M (lbs) (lbs) I - Constructed stormwater pond 2025 0 1215 810 60 BMP Schematic 1 C�sVucted vtomwater pond M1 N Project Information Calculator Version: Version 2: June 2014 Project Name: MMW Proposed Underground Storm Chambers for 2016 User Name / Company Name: Cliff BuhmanAnspec Date: 9-5-15 Project Description: Proposed Underground Storm Chambers to replace Existing North Detention Pond Site Information CITY OFCHANHASSEtl Retention Requirement (inches): 1.1 RECEIVED Site's Zip Code: 55331 Annual Rainfall (inches): 29.6 SEP 0 8 2015 Phosphorus EMC (mg/1): 0.3 TSS EMC (mgA): 54.5 CHAWAMPLANNINGOFFol Total Site Area Land Cover A Soils B Soils C Soils D Soils Total (acres) (acres) (acres) (acres) (acres) Forest/Open Space - Undisturbed, protected 0 forest/open space or reforested land Managed Turf - disturbed, graded for yards or 10.38 10.38 other turf to be mowed/managed Impervious Area (acres) 4.01 Total Area (acres) 14.39 Site Areas Routed to BMPs Land Cover A Soils B Soils C Soils D Soils Total (acres) (acres) (acres) (acres) (acres) Forest/Open Space - Undisturbed, protected 0 forest/open space or reforested land Managed Turf - disturbed, graded for yards or 10.38 10.38 other turf to be mowed/managed Impervious Area (acres) 4.01 Total Area (acres) 14.39 -��CANNEC A, Summary Information Performance Goal Requirement Performance goal volume retention requirement 16012 ft3 Volume removed by BMPs towards performance goal: 7603 ft3 Percent volume removed towards performance goal 47 % Annual Volume and Pollutant Load Reductions (ft3) Upstream Post development annual runoff volume 14.218 acre -ft Annual runoff volume removed by BMPs: 4.5948 acre -ft Percent annual runoff volume removed: 32 % Post development annual particulate P load: 6.38 lbs Annual particulate P removed by BMPs: 2.06 lbs Post development annual dissolved P load: 5.22 lbs Annual dissolved P removed by BMPs: 1.69 lbs Percent annual total phosphorus removed: 32 % Post development annual TSS load: 2108 lbs Annual TSS removed by BMPs: 681 lbs Percent annual TSS removed: 32 % BMP Summary Performance Goal Summary BMP Vol,�me Vo e Volume Volume ercent BMP Name Capacl Retevme'd Retained Outflow Retained (ft3) Upstream (ft3) (It3) M 1 - Infiltration basin/Underground InfiltratiF 7603 16012 1 7603 8409 47 Annual Volume Summary Particulate Phosphorus Summary Volume Load From Volume From Volume Volume Percent BMP Name From Direct Upstream Retained outflow Retained Watershed BMPs (acre -ft) (acre -ft) M (acre -ft) (acre -ft) (Ibs) M 1 - Infiltration basin/Underground Infiltrati 14.218 0 4.5948 9.6232 32 Particulate Phosphorus Summary k Load From Load From Load Outflow Percent BMP Name Direct Upstream Retained Load Retained Watershed BMPs (lbs) (Ibs) M (Ibs) (lbs) I - Infiltration basin/Underground Infiltrati 6.38 0 2.06 4.32 32 k Dissolved Phosphorus Summary TSS Summary Load From Load From Load Outflow Percent BMP Name Direct Upstream Retained Load Retained Upstream Watershed BMPs (lbs) (Ibs) M (lbs) (lbs) (lbs) 1 - Infiltration basin/Underground Infiltrati 5.22 0 1.69 3.53 32 TSS Summary BMIP Schematic 1-9bmn/ Lkx tim Load From Load From Load Outflow Percent BMP Name Direct Upstream Retained Load Retained Watershed BUIPS (lbs) (lbs) M (lbs) (lbs) 1 - Infiltration basin/Underground Infiltrati 2108 0 681 1427 32 BMIP Schematic 1-9bmn/ Lkx tim 41� must be submitted with site plan reviews. NOTE: When multiple applications are processed, the appropriate fee shall be charged for each - application. PROJECT NAME: Minnetonka West Middle School- 2014 Parking Lot Addition & Stormwater Drainage Improvements LOCATION: 6421 Hazelting Blvd., Chanhassen, MN LEGAL DESCRIPTION AND PID LEGAL DESCRIPTION The Southwest Giorter (SW 1/4) of the Northeast Oiarta (NIN 1/4) of section lives (3). Township One Hundred Sixteen (116). Range Twerity Three (23) West according to the U. S. Go,i,ernment Surwt, thersof. excepting thevefirm the 35/100ths mrits conwyed by deed mwded In the office of the Register of Deeds of Co� County. Mimestita. in Back 8 of Deeds. page 400, and that port thereof conwyed by deed recorded In the office of the Registair of Goods of Cw� county, lifinnesato. In Book 41 of Deeds, page 322. and subject to the right, title andl kitesnatt of the State of Monriesoto in that strip of land conwyed by deed recorded in the office of the Registv of Deeds of C� County. Minnesolo. In Book 33 of Deeds. page 25. Also that part of Lot E, Boinivnill Acres, not conwyed by acid deed recorded in the office or the Register of Deeds of carver county. Minnesota. in Book 41 or Deeds, page 322. Subject to a pemncx�,snt easennitint f� roadway purposes as neconled in the office Of the Register of Deeds of Coin,,er county, Mituncoota. in Book 64 of Deeds, page 32. TOTAL ACREAGE:30.711 WETLANDS PRESENT: NO PRESENT ZONING: Office & Instilutional REQUESTED ZONING: No Change PRESENT LAND USE DESIGNATION: School; REQUESTED LAND USE DESIGNATION: No Change REASON FOR REQUEST: FOR SITE PLAN REVIEW: Include number of existing employees: andnewemployees: This application must be completed in full and be typewritten or clearly printed and must be accompanied by all information and plans required by applicable City Ordinance provisions. Before filing this application, you should confer with the Planning Department to determine the specific ordinance and procedural requirements applicable to your application. A determination of completeness of the application shall be made Wthin 15 business days of application submittal. A written notice of application deficiencies shall be mailed to the applicant within 15 business days of application. CITY OF CHANHASS& RECEIVED SEP 0 h 2015 CHANHASSEN PLANNING DEPT COMMUNITY DEVELOPMENT DEPARTMENT Planning Division — 7700 Market Boulevard Mailing Address — P.O. Box 147, Chanhassen, MN 55317 Phone: (952) 227-1130 / Fax: (952) 227-1110 * CITY OF CHEASSEN AGENCY REVIEW REQUEST LAND DEVELOPMENT PROPOSAL I Please review and respond no later than the review response deadline Agency Review Request Date: September 10, 2015 Agency Review Response Deadline: September 24,2015 Date Application Filed: September 8, 2015 Contact: Contact Phone: Contact Email: Robert Generous, AICP 952-227-1131 bgenerous@ci.chanhassen.mn.us Senior Planner Building Official Planning Commission Date: City Council Date: 60 -Day Review Period Deadline: October 6, 2015 at 7:00 p.m. October 26, 2015 at 7:00 p.m. November 7, 2015 Application: Request for Interim Use Permit to permit site grading to construct a parking lot and an underground storm chamber system, widen the main entrance/exit driveway, and construct new paths between the tennis courts. The property is zoned Office and Institutional District (01) and located at 6421 Hazeltine Boulevard. Applicant/Owner: Minnetonka Schools, ISD #276. Planning Case: 2015-23 1 Web Page: www.ci.chanhassen.mn.us/2015-23 In order for staff to provide a complete analysis of issues for Planning Commission and City Council review, we would appreciate your comments and recommendations concerning the impact of this proposal on traffic circulation, existing and proposed future utility services, storm water drainage, and the need for acquiring public lands or easements for park sites, street extensions or improvements, and utilities. Where specific needs or problems exist, we would like to have a written report to this effect from the agency concerned so that we can make a recommendation to the Planning Commission and City Council. Your cooperation and assistance is greatly appreciated. City Departments: Federal Agencies: Adaacent Cities: ED Attorney El Army Corps of Engineers El Chaska Building Official US Fish & Wildlife El Eden Prairie Engineer El Jackson Township Fire Marshal Watershed Districts: Minnetonka Z Forester Park Director El Carver County WMO F-1 Shorewood Victoria E Water Resources M Lower MN River El Law Enforcement Z Minnehaha Creek Adoacent Counties: El Riley -Purgatory -Bluff Creek Carver County Agencies: Utilities: E] F-1 Hennepin Scott El El Community Development Engineer El Cable TV — Mediacom El Environmental Services 0 Electric — Minnesota Valley School Districts: F-1 Historical Society El Electric — Xcel Energy El Eastern Carver County 112 El Parks El Magellan Pipeline 0 Minnetonka 276 Z Soil & Water Conservation District Ej Natural Gas — CenterPoint Energy El Phone — CenturyLink Other Agencies: State Aaencies: Hennepin County Regional Railroad Board of Water & Soil Resources El Authority MN Landscape Arboretum El Health Historical Society F1 SouthWest Transit El Natural ResourGes-Forestry El TC&W Railroad El Natural Resources -Hydrology El Pollution Control Z Transportation SCANNED CITY OF CHANHASSEN P 0 BOX 147 CHANHASSEN MN 55317 09/09/2015 3:35 PM Receipt No. 00294477 CLERK: AshleyM PAYEE: Minnetonka School 5621 County Road 101 Minnetonka MN 55345 - Planning Case 2015-23 ------------------------------------------------------- Interim Use Permit 425.00 Sign Rent 200.00 Recording Fees 50.00 GIS List 195.00 Total Cash Check 421812 Change ----------- 870.00 0.00 870.00 ----------- 0.00 SCANNED MINNETONKA MIDDLE SCHOOL WEST IUP - PLANNING CASE 20`15-23 $425.00 Interim Use Permit $200.00 Notification Sign $195.00 Property Owners' List $50.00 Escrow for filing fees $870.00 TOTAL $870.00 Less Check 421812 from Minnetonka School District No. 276 $0.00 BALANCE REMAINING TO BE PAID SCANNED MST. STORMWAMR AREAS I MaODY u ;o 1 4 SHIVEJ A ADDIn 3 I MaODY u p lll!�l WoRlsom"IEW! 4- room Jxs,zc ww� Ac� L;ITY0FCHANHAS'QEtl RECEIVED IT SEP 0 8 2015 Ay f'EXDS 1ANHASSEN PLANNING DFIPT 2 ;o 1 4 SHIVEJ A ADDIn 3 p lll!�l WoRlsom"IEW! 4- room Jxs,zc ww� Ac� L;ITY0FCHANHAS'QEtl RECEIVED IT SEP 0 8 2015 Ay f'EXDS 1ANHASSEN PLANNING DFIPT 2 SCANNED MINNETONKA PUBLIC SCHOOLS ISO - 276 MINNETONKA MIDDLE SCHOOL WEST .�EC SHT 1 OF 1 ;o 1 SHIVEJ A ADDIn 3 Ell HIM aw— Nwm MAD EXISTNG STORMWATER DRAINAGE AREAS SCANNED MINNETONKA PUBLIC SCHOOLS ISO - 276 MINNETONKA MIDDLE SCHOOL WEST .�EC SHT 1 OF 1 West Grass & nnis Courts GITYOKHANHASSEN RECEIVED SEP 0 8 2015 CHANHASSEN PLANNING DEPT �'l West Filtration Eas iltration Swale /I CJ\B Loi /Grass Fields & Tennis Cts Main Parking Lot Det Pond Det Pond scmNal S.ubcat FRSB�Ch MMW E)dst Pond 2003 Design 8-28-15 Prepared by Microsoft Printed 9/8/2015 HydroCAD010.00-12 s/nG6027 @2014 HydroCAD Software Solutions LLC Page 2 Area Listing (all nodes) Area (acres) CN Description (subcatchment-numbers) 0.540 39 >75% Grass cover, Good, HSG A (Al 1) 10.050 61 >75% Grass rover, Good, HSG B (Al, A2, A3) 1.963 98 Parking Lot (A3) 1.227 98 Path (Al, A2) 0.254 98 Pond (Al 1) 14.034 69 TOTAL AREA MMW Exist Pond 2003 Design 8-28-15 Prepared by Microsoft Printed 9/a/2015 HydroCAD@)10.00-12 s/nO6O27 @2014 HydroCAD Software Solutionst-l-C Pace 3 Soil Listing (all nodes) Area Soil Subcatchment (acres) Group Numbers 0.540 HSG A All 10.050 HSG B Al, A2, A3 0.000 HSG C 0.000 HSG D 3.444 Other Al,All,A2,A3 14.034 TOTAL AREA MMW Exist Pond 2003 Design 8-28-15 Prepared by Microsoft HvdroCAI)@ 10.00-12 sIn 06027 @ 2014 HvdroCAD Software Ground Covers (all nodes) Printed 9/812015 HSG -A HSG -B HSG -C HSG -D Other Total Ground Subcatchment (acres) (acres) (acres) (acres) (acres) (acres) Cover Numbers 0.540 10.050 0.000 0.000 0.000 10.590 >75% Grass cover, Good Al, All, A2, A3 0.000 0.000 0.000 0.000 1.963 1.963 Parking Lot A3 0.000 0.000 0.000 0.000 1.227 1.227 Path Al, A2 0.000 0.000 0.000 0.000 0.254 0.254 Pond All 0.540 10.060 0.000 O.ODO 3.444 14.034 TOTAL AREA MMW Exist Pond 2003 Design B-28-15 Prepared by Microsoft Printed 9/812015 HydroCAD010.00-12 s/n06027 @2014 HydroCAD Software Solutions LLC Paue 5 Pipe Listing (all nodes) Une# Node In -invert Out -invert Length Slope n Diam/Width Height Inside -Fill Number (feet) (feet) (feet) (ft/ft) (inches) (inches) (inches) 1 1 1,043.50 1,043.67 35.0 -0.0049 0.015 24.0 0.0 0.0 2 1P 1,055.00 1,046.00 140.0 0.0643 0.010 18.0 0.0 0.0 3 2P 1,046.50 1,046.00 30.0 0.0167 0.010 12.0 0.0 0.0 4 3P 1,043.64 1,043.20 50.0 0.0088 0.015 18.0 0.0 0.0 MMW Exist Pond 2003 Design 8-28-15 Type // 24 -hr 1 year Rainfall=2.30" Prepared by Microsoft Printed 9/8/2015 HvdroCAD(E) 10.00-12 s/n 06027 @2014 HvdroCAD Software Solutions Ll -C Pace 6 Time span=0.00-72.00 hrs, dt=0.01 hrs, 7201 points Runoff by SCS TR -20 method, UH=SCS, Weighted-CINI Reach routing by Dyn-Stor-Ind method - Pond routing by Dyn-Stor-Ind method Subcatchment Al: East Grass Fields & Tennis Runoff Area=6.467 ac 10.65% Impervious Runoff Depth=0-23" Flow Length=400' Tc=45.0 min CN=65 Runoff=0.48 cfs 0.122 af Subcatchment All: Det Pond Runoff Area=0.794 ac 31.99% Impervious Runoff Depth=0.09" Flow Length=100' Tc=6.3 min CN=58 Runoff=0.01 cfs 0.006 af Subcatchment A2: West Grass & Tennis Courts Runoff Area=0.813 ac 66.17% Impervious Runoff Depth=1.02" Flow Length=600' Tc=30.6 min CN=85 Runoff =0.70 cfs 0.069 af Subcatchment A3: Main Parking Lot Runoff Area=5.960 ac 32.94% Impervious Runoff Depth=0.46" Flow Length=350' Tc=10.8 min CN=73 Runoff=3.61 cfs 0.230 af Pond 1: Peak Elev--1,044.62' Inflow=3.61 cfs 0.230 af 24.0" Round Culvert n=0.01 5 L=35.0' S=-0.0049 T Outflow=3.61 cfs 0.230 af Pond 1 P: East Filtration Swale Peak Elev--1,060.12' Storage=0.084 af lnflow=0.48 cfs 0.122 af Discarded=0.05 cfs 0.112 af Pdmary--0.00 cfs 0.000 af Outflow=0.05 cfs 0. 112 af Pond 2P: West Filtration Swale Peak Elev=1,050.98' Storage=0.037 af Inflow=0.70 cfs 0.069 af Discarded=0.04 efs 0.061 af Primary --0.04 cfs 0.008 af Outflow=0.07 cfs 0.069 af Pond 3P: Det Pond Peak Elev--1,040.61' Storage=0.237 af Inflow=3.62 cfs 0.244 af Discarded=0.01 cfs 0.040 af Pdmary--0.00 cfs 0.000 af Outflow=0.01 cfs 0.040 af Total Runoff Area = 14.034 ac Runoff Volume = 0.427 af Average Runoff Depth = 0.37" 75.46% Pervious = 10.590 ac 24.54% Impervious = 3.444 ac MMW Exist Pond 2003 Design 8-28-15 Type // 24 -hr 1 year Rainfall=2.30" Prepared by Microsoft Printed 9/812015 HydroCAD010.00-12 stnO6O27 (92014 HydroCAD Software Solutions LLC Paae 7 Sumniary for Subcatchnient All: East Grass Fields & Tennis Cts Runoff 0.48 cfs @ 12.60 hrs, Volume= 0. 122 af, Depth= 0.23" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr 1 year Rainfall=2.30" Area (ac) CN Description 5.778 61 >75% Grass cover, Good, HSG B 0.689 98 Path 6.467 65 Weighted Average 5.778 89.35% Pervious Area 0.689 10.65% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (fVft) (ft/sec) (dS) 43.6 300 0.0150 0.11 Sheet Flow, Existing grass play field Grass: Dense n= 0.240 P2= 2.50" 1.4 100 0.0200 1.22 Sheet Flow, Paved Path Smoothsurfaces n=0.011 P2=2.50" 45.0 400 Total Subcatchment All: East Grass Fields & Tennis Cts 0.48 cfs 0.3 0.25 0.2 0.1 Hydrograph Type ll 24 -hr 1 year Rainfall=2.30" Runoff Area=6.467 ac Runoff Volume=0.122 af Runoff Depth=0.23" Flow Length=400' Tc=45.0 min CN=65 0 0 2 4 6 8 10 12 14 16 18 20 22 24 i6 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Tim (houm) MMW Exist Pond 2003 Design 8-28-15 Type // 24 -hr I year Rainfall=2-30" Prepared by Microsoft Printed 9/8/2015 HydroCAD@)10.00-12 s/nO6O27 @2014 HydroCAD Software Solutions LLC Page 8 Summary for Subcatchment All: Dot Pond Runoff 0.01 ds @ 12.37 hrs, Volume= 0.006 af, Depth= 0.09" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr 1 year Rainfall=2.30" Area (ac) CN 0.254 98 Pond 0.540 39 >75% Grass cover, Good, HSG A 0.794 58 Weighted Average 0.540 68.01 % Pervious Area 0.254 31.99% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (Gfs) 1.4 50 0.0050 0.61 Sheet Flow, Minnetonka HS 0.008 Runoff Depth=0.09" 0.007 Smoothsurfaces; n=0.011 P2=2.50" 4.9 50 0.1000 0.17 Sheet Flow, 0.005 Grass: Dense n= 0.240 P2= 2.50" 6.3 100 Total Subcatchment All: Det Pond Hydrograph 0.013 0.012 Type 11 24 -hr 0.011- 1 year Rainfall=2.30" 0.01� Runoff Area=0.794 ac 0.009- Runoff Volume=0.006 af 0.008 Runoff Depth=0.09" 0.007 Flow Length=100' 0.006 0.005 Tc=6.3 min 0.004 CN=58 0.003 30 32 34 36 38 4 Tim (houm) MMW Exist Pond 2003 Design 8-28-15 Type // 24 -hr I year Rainfall=2.30" Prepared by Microsoft Printed 9/8/2015 HydroCAD@)10.00-12 stn06O27 @2014 HydroCAD Software Solutions LLC Pacie 9 Surnrnary for Subcatchment A2: West Grass & Tennis Courts Runoff 0.70 cfs @ 12.27 hrs, Volume= 0.069 af, Depth= 1.02" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr 1 year Rainfall=2.30" Area (ac) CN Description 0.538 98 Path 0.275 61 >75% Grass cover. Good. HSG B 0.813 85 Weighted Average 0.275 33.83% Pervious Area 0.538 66.17% Impervious Area Te Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 3.7 300 0.0150 1.35 Sheet Flow, Minnetonka HS Smoothsurfaces n=0.011 P2=2.50" 26.9 300 0.0500 0.19 Sheet Flow, West Grass Grass: Dense n= 0.240 P2= 2.50" 30.6 600 Total 0.1 Subcatchment A2: West Grass & Tennis Courts Hydrograph 0.70 cfs Type 11 24 -hr 1 year Rainfall=2.30" Runoff Area=0.813 ac Runoff Volume=0.069 af Runoff Depth=1.02" Flow Length=600' Tc=30.6 min 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 TIM (hom) CN=85 MMW Exist Pond 2003 Design 8-28-15 Type // 24 -hr I year Rainfall=2.30" Prepared by Microsoft Printed 9/8/2015 HydroCADO 10.00-12 s/n 06027 0 2014 HydroCAD Software Solutions LLC Page 10 Summary for Subcatchment Al Main Parking Lot Runoff 3.61 efs @ 12.04 hrs, Volume= 0.230 af, Depth= 0.46" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr 1 year Rainfall=2.30" Area (ac) CN DescriDtion 1.963 98 Parking Lot 3.997 61 >75% Grass r -over, Good, HSG B 5.960 73 Weighted Average 3.997 67.06% Pervious Area 1.963 32.94% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 4.4 300 0.0100 1.15 Sheet Flow, Minnetonka HS Smoothsurfaces n=0.011 P2=2.50" 6.4 50 0.0200 0.13 Sheet Flow, Grass:Short n=0.150 P2=2.50" 10.8 350 Total Subcatchment Al Main Parking Lot Hydrograph Type 11 24 -hr 31 1 1 year Rainfall=2.30" Runoff Area=5.960 ac Runoff Volume=0.230 af F ��L 21 1 Runoff Depth=0.46" Flow Length=350' Tc=10.8 min CN=73 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Tim (houm) MMW Exist Pond 2003 Design 8-28-15 Type // 24 -hr 1 year Rainfall=2.30" Prepared by Microsoft Printed 9/812015 HydroCAD@)10.00-12 s/nO6O27 @2014 HydroCAD Software Solutions LLC Paae 11 Surnfriary for Pond 1: [57] Hint: Peaked at 1,044.62'(Flood elevation advised) Inflow Area 5.960 ac, 32.94% Impervious, Inflow Depth = 0.46" for 1 year event Inflow 3.61 cfs @ 12.04 hrs, Volume= 0.230 af Outflow 3.61 cfs @ 12.04 hrs, Volume= 0.230 af, Atten= 0%, Lag= 0.0 min Primary 3.61 cfs @ 12.04 hrs, Volume= 0.230 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,044.62'@ 12.04 hrs Device Routing Invert Outlet Devices #1 Primary 1,043.67' 24.0" Round Culvert L= 35.0' RCP, sq.cut end projecting, Ke= 0.500 Inlet/ Outlet Invert= 1,043.50'/ 1,043.67' S= -0.0049'p Cc=0.900 n= 0.015 Concrete sewer w/manholes & inlets, Flow Area= 3.14 sf Primary OutFlow Max=3.61 cfs @ 12.04 hrs HW=1,044.62' TW=1,036.62' (Dynamic Tailwater) '�--I!=Culvert (Barrel Controls 3.61 cfs @ 2.88 fps) Pond 1: Hydrograph 4- 0 Pnmary 1 3.6 Inflow Area=5.960 ac Peak Elev=1,044.62' 3- 24.011 Round Culvert 2- n=0.01 5 L=35.0' S=400497' 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Tim (houm) MMW Exist Pond 2003 Design 8-28-15 Type // 24 -hr I year Rainfall=2.30" Prepared by Microsoft Printed 9/812015 HydroCAD@10.00-12 s/n06027 @2014 HydroCAD Software Solutions LLC Page 12 Summary for Pond 1P: East Filtration Swale Inflow Area 6.467 ac, 10.65% Impervious, Inflow Depth= 0.23" for 1 year event Inflow 0.48 cfs @ 12.60 hrs, Volume= 0.122 af Outflow 0.05 cfs @ 24.34 hrs, Volume= 0.112 af, Atten= 89%, Lag= 704.0 min Discarded 0.05 cfs @ 24.34 hrs, Volume= 0.112 af Primary 0.00 cis @ 0.00 hrs, Volume= 0.000 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,060.12'@ 24.34 hrs Surf.Area= 0.141 ac; Storage= 0.084 af Plug -Flow detention time= 1,127.4 min calculated for 0.112 af (92% of inflow) Center -of -Mass det. time= 1,086.9 min ( 2,061.6 - 974.7 ) Volume Invert Avail.Storage Storage Description #1 1,059.00' 0.343 af Custom Stage Data (Prismatic) Listed below (Recalc) Elevation SurfArea Inc.Store Cum.Store (feet) (acres) (acre-feet) (acre-feet) 1,059.00 0.040 0.000 0.000 1,060.00 0.100 0.070 0.070 1,061.00 0.447 0.273 0.343 Device Routing Invert Outlet Devices #1 Primary 1,055.00- 18.0" Round Culvert L= 140.0' RCP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 1,055.00'/ 1,046.00' S= 0.0643 7' Cc= 0.900 n= 0.010 PVC, smooth interior, Flow Area= 1.77 sf #2 Device 1 1,060.40' 24.0"Horiz.Orifice/Grate C=0.600 Limited to weir flow at low heads #3 Discarded 1,059.00' 0.500 in/hr ExHitration over Surface area from 1,059.00'- 1,060.50' Excluded Surface area = 0.040 ac: Phase -In= 0.01' Discarded OutRow Max=0.05 cfs @ 24.34 hrs HW=1,060.12' (Free Discharge) t--3--Exfiltration (Exfiltration Controls 0.05 ds) Primary OutFlow Max=0.00 cfs @ 0.00 hrs HW=1,059.00' TW=1,034.00' (Dynamic Tailwater) t--l=Culvert (Passes 0.00 ds of 13.53 cfs potential flow) t--2=0rificelGrate ( Controls 0.00 cfs) MMW Exist Pond 2003 Design 8-28-15 Type // 24 -hr 1 year Rainfafi=2.30" Prepared by Microsoft Printed 9/8/2015 HydroCAD(510.00-12 s/nO6O27 @2014 HydroCAD Software Solutions LLC Pacie 13 0.1 Pond 1 P: East Filtration Swale Hydrograph 0 Inflm L] Oufflm 0 Djs�rded Inflow Area=6.467 ac IN Pnmary I Peak Elev=1,060.12' Storage=0.084 af 0 2 4 6 8 10121416182022242628303234363840424446485052545658606264666870 Tim jhoum) MMW Exist Pond 2003 Design 8-28-15 Type // 24 -hr I year Rainfall=2.30" Prepared by Microsoft Printed 9/8/2015 HydroCAD010.00-12 s/nO6O27 @2014 HydroCAD Software Solutions LLC Page 114 Summary for Pond 2P: West Filtration Swale Inflow Area 0.813 ac, 66.17% Impervious, Inflow Depth= 1.02" for 1 year event Inflow 0.70 cfs @ 12.27 hrs, Volume= 0.069 af Oufflow 0.07 cfs @ 13.67 hrs, Volume= 0.069 af, Atten= 89%, Lag= 84.3 min Discarded 0.04 cfs @ 13.67 hrs, Volume= 0.061 af Primary 0.04 cfs @ 13.67 hrs, Volume= 0.008 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,050.98'@ 13.67hrs Surf.Area=0.080ac Storage=0.037af Plug -Flow detention time= 493.7 min calculated for 0.069 af (100% of inflow) Center -of -Mass det. time= 493.6 min ( 1,355.0 - 861.4 ) Volume Invert Avail.Storage Storage Description #1 1,050.00, 0.038 af Custom Stage Data (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (acres) (acre-feet) (acre-feet) 1,050.00 0.018 0.000 0.000 1,050.50 0.027 0.011 0.011 1,051.00 0.082 0.027 0.038 Device Routing Invert Outlet Devices #1 Primary 1,046.50' 12.0" Round Culvert L= 30.0' RCP, mitered to conform to fill, Ke= 0.700 Inlet/ Outlet Invert= 1,046.50'/ 1,046.00' S=0.0167'f Cc=0.900 n= 0.010 PVC, smooth interior, Flow Area= 0.79 sf #2 Device 1 1,050.90' 24.0" Vert Orifice/Grate C= 0.600 #3 Discarded 1,050.00' 0.500 in/hr Exfiltration over Horizontal area from 1,049.W - 1,050.90' Conductivity to Groundwater Elevation = 0.00' Excluded Horizontal area = 0.000 ac Phase -In= 0.01' Discarded OutFlow Max=0.04 cfs @ 13.67 hrs HW=1,050.98' (Free Discharge) t-3--Exriltration ( Controls 0.04 ds) Primary OutFlow Max=0.04 ds @ 13.67 hrs HW=1,050.98' TW=1,039.07' (Dynamic Tailwater) t—l=Culvert (Passes 0.04 cfs of 6.66 efs potential flow) 't-2--Orifice/Grate (Orifice Controls 0.04 cfs @ 0.95 fps) MMW Exist Pond 2003 Design 8-28-15 Type I/ 24 -hr 1 year Rainfall=2.30" Prepared by Microsoft Printed 9/8/2015 HydroCAD@10.00-12 sfn06027 @2014 HydroCAD Software Solutions LLC Page 15 Pond 2P: West Filtration Swale Hydrograph Time j1hours) 0 Inflow E outflow 13 Discarded 0 Primary MMW Exist Pond 2003 Design 8-28-15 Type /I 24 -hr I year Rainfall=2.30" Prepared by Microsoft Printed 9/8/2015 HydroCAD@)10.00-12 s1n06027 02014 HydroCAD Software Solutions LLC Page 16 Summary for Pond 3P: Det Pond Inflow Area 14.034 ac, 24.54% Impervious, Inflow Depth = 0.21" for I year event Inflow 3.62 cfs @ 12.04 hrs, Volume= 0.244 af Outflow 0.01 ds @ 24.26 hrs, Volume= 0.040 af, Atten= 100%, Lag= 733.1 min Discarded 0.01 ds @ 24.26 hrs, Volume= 0.040 af Primary 0.00 cfs @ 0.00 hrs, Volume= 0.000 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,040.61'@ 24.26 hrs Surf.Area= 0.086 ac Storage= 0.237 af Plug -Flow detention time= 1,824.5 min calculated for 0.040 af (16% of inflow) Center -of -Mass det. time= 1,648.3 min ( 2,543.8 - 895.4 ) Volume Invert Avail.Storage Storage Description #1 1,034.00' 1.327 af Custom Stage Data (Prismatic) Listed below (Recale) Elevation Surf.Area Inc.Store Cum.Store (feet) (acres) (acre-feet) (acre-feet) 1,034.00 0.005 0.000 0.000 1,035.00 0.010 0.008 0.008 1,036.00 0.017 0.013 0.021 1,037.00 0.027 0.022 0.043 1,038.00 0.040 0.033 0.077 1,039.00 0.055 0.048 0.124 1,040.00 0.073 0.064 0.188 1,041.00 0.095 0.084 0.272 1,042.00 0.122 0.109 0.381 1,043.00 0.183 0.152 0.533 1,044.00 0.254 0.219 0.752 1,045.00 0.287 0.270 1.022 1,046.00 0.323 0.305 1.327 Device Routing Invert Outlet Devices #1 Primary 1,043.64' 18.0" Round Surface Outlet L= 50.0' RCP, mitered to conform to fill, Ke= 0.700 Inlet/ Outlet Invert= 1,043.64'/ 1,043.20' S=0.0088'P Cc=0.900 n= 0.015 Concrete, trowel finish, Flow Area= 1.77 sf #2 Device 1 1,045.44' 24.0"Horiz.Orifice/Grate C=0.600 Limited to weir flow at low heads #3 Discarded 1,034.00' 0.100 inthr Exfiltrartion over Surface area Conductivity to Groundwater Elevation = 0.00' Phase -In= 0.01' Discarded OutFlow Max=0.01 cfs @ 24.26 hrs HW=1,040.61' (Free Discharge) 't-4--ExINifiration (Controls 0.01 cfs) Primary OutFlow Max=0.00 cfs @ 0.00 hrs HW=1,034.00' (Free Discharge) 't--1=Surface Outlet ( Controls 0.00 cfs) 't-2=Orifice/Grate ( Controls 0.00 cfs) MMW Exist Pond 2003 Design 8-28-15 Prepared by Microsoft HvdroCAD@10.OG-12 s(n06O27 02014HvdmC, a Type // 24 -hr I year Rainfall=2.30" Printed 9/812015 Pond 3P: Det Pond Hydrograph 0 Inflm F— oulfim 4 Inflow Area=141034 ac M Di�rded M Pnmary Peak Elev=1,040.61' I Storage=0.237 af 2 .2 W 0 2 4 6 8 1012141618202224262830323436384042444648505254565860626466687072 Tim (houm) MMW Exist Pond 2003 Design 8-28-15 Type // 24 -hr 10 year Rainfall=4-15" Prepared by Microsoft Printed 9/a/2015 HvdroCAD@)10.00-12 s/nG6027 02014 HvdroCAD Software Solutions LLC Paqe 18 Time span=0.00-72.00 hrs, dt=0.01 hrs, 7201 points Runoff by SCS TR -20 method, UH=SCS, Weighted -CN Reach routing by Dyn-Stor-Ind method - Pond routing by Dyn-Stor-Ind method SubcatchmentAl: East Grass Fields &Tennis Runoff Area=6.467ac 10.65%Impervious Runoff Depth=1.12" FlowLength=400' Tc=45.Omin CN=65 Rurioff=4.13cfsO.602af Subcatchment All: Det Pond Runoff Area=0.794ac 31.99%Impervious Runoff Depth=0.73" FlowLength=100' Tc=6.3min CN=58 Runoff=0.91cfsO.049af Subcatchment A2: West Grass& Tennis Courts Runoff Area=0.813 ac 66.17% Impervious Runoff Depth=2.59" FlowLength=600' Tc=30.6min CN=85 Runoff=1.80cfso.176af Subcatchment A3: Main Parldng Lot Runoff Area=5.960 ac 32.94% Impervious Runoff Depth=11.64" Flow Length=350' Tc=10.8 min CN=73 Runoff--14.51cfs 0.813 af Pond 1: Peak Elev--1,046.19' Inflow --14.51 cfs 0.813 af 24.0" Round Culvert n=0.015 L=35.0' S= -0.0049'P Outflow --14.51 cfs 0.813 af Pond 1P: East Filtration Swale Peak Eiev--1,060.60' Storage=0.193af Inflow=4.13cfs 0.602 af Discarded=0.12 ds 0.237 af Primary --1.88 cfs 0.348 af Outflow=2.00 cfs 0.585 af Pond 2P: West Filtration Swale Peak Elev--1,051.64' Storage=0.038 af Inflow --1.80 cfs 0.176 af Discarded=0.04 cfs 0.073 af Primary --3.12 cfs 0.103 af Outflow=3.15 cfs 0.176 af Pond 3P: Det Pond Peak Elev--1,045.50' Storage=1.171 af Inflow --15.30 Gfs 1.312 af Discarded=0.03 cfs 0.147 af Primary --0.33 cfs 0.125 af Outflow --0.36 Gfs 0.272 af Total Runoff Area = 14.034 ac Runoff Volume = 1.638 af Average Runoff Depth = 1.40" 75AW16 Pervious = 10.590 ac 24.54% Impervious = 3.444 ac MMW Exist Pond 2003 Design B-28-15 Type // 24 -hr 10 year Rainfall=4. 15" Prepared by Microsoft Printed 9/812015 HydroCAD@)10.00-12 s/nO6027 @2014 HydroCAD Software Solutionst-l-C Page 19 Surnrnary for Subcatchnient Al: East Grass Fields & Tennis Cts Runoff 4.13 cfs @ 12.46 hrs, Volume= 0.602 af, Depth= 1.12" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr 10 year Rainfall=4.15" Area (ac) CN DesCriDtion 5.778 61 >75% Grass cover, Good, HSG B 0.689 98 Path 6.467 65 Weighted Average 5.778 89.35% Pervious Area 0.689 10.65% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (fUft) (ft/sec) (cfs) 43.6 300 0.0150 0.11 Sheet Flow, Existing grass play field Grass: Dense n= 0.240 P2= 2.50" 1.4 100 0.0200 1.22 Sheet Flow, Paved Path Smoothsurfaces n=0.011 P2=2.50" 45.0 400 Total Subcatchment Al: East Grass Fields & Tennis Cts Hydrograph 4] 1 Type 11 24 -hr 10 year Rainfall=4.15" 31 1 Runoff Area=6.467 ac Runoff Volume=0.602 af Runoff Depth=1.12" 21 1 Flow Length=400' Tc=45.0 min CN=65 0 MW 0 2 4 6 � 10 1'2 14 16 1'8 20 i2 i4 26 28 30 32 i4 36 38 40 42 44 46 48 M �2 54 �6 i8 6 6 6� 66 68 70 72 T1M (houm) MMW Exist Pond 2003 Design 8-28-15 Type // 24 -hr 10 year Rainfall=4.15" Prepared by Microsoft Printed 9/8/2015 HydroCAD@)10.00-12 s/n06O27 @)2014 HydroCAD Software Solutionsi-l-C Paae 20 Summary for Subcatchment All: Det Pond Runoff 0.91 cfs @ 11.99 hrs, Volume= 0.049 af, Depth= 0.73" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr 10 year Rainfall=4.15" Area (ac) CN DescriDtion 0.254 98 Pond 0.540 39 >75% Grass cover, Good, HSG A 0.794 58 Weighted Average 0.540 68.01% Pervious Area 0.254 31.99% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (fttsec) (cfs) 1.4 50 0.0050 0.61 Sheet Flow, Minnetonka HS Smoothsurfaces n=0.011 P2=2.50" 4.9 50 0.1000 0.17 Sheet Flow, Grass: Dense n= 0.240 P2= 2.50" 6.3 100 Total 2 4 6 Subcatchment All: Det Pond Hydrograph 10 year Type 11 24 -hr Rainfall=4.15" Runoff Area=0.794 ac Runoff Volume=0.049 af Runoff Depth=0.73" Flow Length=100' 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 Tim (houm) Tc=6.3 min CN=58 6264 MMW Exist Pond 2003 Design 8-28-15 Type // 24 -hr 10 year Rainfall=4.15" Prepared by Microsoft Printed 9/8/2015 HydroCAD@)10.00-12 s/n06O27 02014 HydroCAD Software Solutions LLC Page 21 Summary for Subcatchnient A2: West Grass & Tennis Courts Runoff 1.80 efs @ 12.24 hrs, Volume= 0.176 af, Depth= 2.59" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr 10 year Rainfall=4.15" Area (ac) CINI DescriDtion 0.538 98 Path 0.275 61 >75% Grass cover, Good, IHISG B 0.813 85 Weighted Average 0.275 33.83% Pervious Area 0.538 66.17% Impervious Area Tc Length Slope Velocity Capacity Description 3.7 300 0.0150 1.35 Sheet Flow, Minnetonka HS Smoothsurfaces n=0.011 P2=2.50" 26.9 300 0.0500 0.19 Sheet Flow, West Grass Grass: Dense n= 0.240 P2= 2.50" 30.6 600 Total Subcatchnient A2: West Grass & Tennis Courts Hydrograph Type 11 24 -hr 10 year Rainfall=4.15" Runoff Area=0.813 ac Runoff Volume=0.176 af Runoff Depth=2.59" Flow Lenoth=600' I I M Tc=30.6 min A r Z U. -R, 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Tim (houm) MMW Exist Pond 2003 Design 8-28-15 Type// 24 -hr 10 year Rainfall=4.15" Prepared by Microsoft Printed 9/8/2015 HydroCAD(D10.00-12 s/n06O27 Q2014 HydroCAD Software Solutions LLC Paae 22 Summary for Subcatchment Al Main Parking Lot Runoff 14.51 ds @ 12.03 hrs, Volume= 0.813 af, Depth= 1.64" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr 10 year Rainfall=4.15" Area (ac) CN DescriDtion 1.963 98 Parking Lot 3.997 61 >75% Grass cover, Good, HSG B 5.960 73 Weighted Average 3.997 67.06% Pervious Area 1.963 32.94% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 4.4 300 0.0100 1.15 Sheet Flow, Minnetonka HS Smoothsurfaces n=0.011 P2=2.50" 6.4 50 0.0200 0.13 Sheet Flow, Grass: Short n= 0.150 P2= 2.50" 10.8 350 Total Subcatchment Al Main Parking Lot Hydrograph 16 15 14 Type 11 24 -hr 13 10 year Rainfali=4.15" 12 ill I Runoff Area=5.960 ac 101 1 0 Runoff Volume=0.813 af i4� Runoff Depth=1.64" g 8 4 9711 1 Flow Length=350' 61 1 E Tc=10.8 min 51 1 1 0 CN=73 24 26 28 30 32 34 36 38 40 42 44 46 48 50 Tim (houm) MMW Exist Pond 2003 Design 8-28-15 Prepared by Microsoft Summary for Pond 1: [57] Hint: Peaked at 1,046.19'(Flood elevation advised) Type // 24 -hr 10 year Rainfall=4.15" Printed 9/8/2015 Inflow Area 5.960 ac, 32.94% Impervious, Inflow Depth = 1.64" for 10 year event Inflow 14.51 cfs @ 12.03 hrs, Volume= 0.813 af Outflow 14.51 cfs @ 12.03 hrs, Volume= 0.813 af, Atten= 0%, Lag= 0.0 min Primary 14.51 ds @ 12.03 hrs, Volume= 0.813 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,046.19' @ 12.03 hrs Device Routing Invert Outlet Devices #1 Primary 1,043.67' 24.0" Round Culvert L= 35.0' RCP, sq.cut end projecting, Ke= 0.500 Inlet/ Outlet Invert= 1,043.50'/ 1,043.67' S= -0.0049P Cc=0.900 n= 0.015 Concrete sewer w/manholes & inlets, Flow Area= 3.14 sf Primary OutFlow Max=14.50 Gfs @ 12.03 hrs HW=1,046.19' TW=1,040.35' (Dynamic Taitwater) t—I=Culvert (Barrel Controls 14.50 cfs @ 4.62 fps) Pond 1: Hydrograph 16� 15 14. Inflow Area=5.960 ac 14 13� Peak Elev=1,046.19' 12 of 11 24.0 10� Round Culvert F 9 8 n=0.015 7 61 L=35.0' 5 1 S=-0.00497' 3 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 Tim (hom) F ----J E Infi. 0 Pnmary MMW E)dst Pond 2003 Design 8-28-15 Type 11 24 -hr 10 year Rainfall=4.15" Prepared by Microsoft Printed 9/8/2015 HydroCAD810.00-12 s1n06027 02014 HydroCAD Software Solutions LLC Page 24 Summary for Pond 1P: East Filtration Swale Inflow Area 6.467 ac, 10.65% Impervious, Inflow Depth = 1.12" for 10 year event Inflow 4.13 cfs @ 12.46 hrs, Volume= 0.602 af Outflow 2.00 cfs @ 13.01 hrs, Volume= 0.585 af, Atten= 52%, Lag= 33.4 min Discarded 0.12cfs@ 12.67hrs, Volume= 0.237 af Primary 1.88 cfs @ 13.01 hrs, Volume= 0.348 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,060.60'@ 13.01 hrs Surf.Area= 0.309 ac Storage= 0.193 af Plug -Flow detention time= 383.3 min calculated for 0.585 af (97% of inflow) Center -of -Mass det. time= 368.3 min ( 1,274.6 - 906.4 ) Volume Invert Avail.Storaqe Storage Description #1 1,059.00' 0.343af Custom Stage Data (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (acres) (acre-feet) (acre-feet) 1,059.00 0.040 0.000 0.000 1,060.00 0.100 0.070 0.070 1,061.00 0.447 0.273 0.343 Device Routing Invert Outlet Devices #1 Primary 1,055.00' 18.0" Round Culvert L= 140.0' RCP, mitered to conform to fill, Ke= 0.700 Inlet/ Outlet Invert= 1,055.00'/ 1,046.00' S=0.0643P Cc=0.900 n=0.010 PVC, smooth interior, FlowArea=1.77sf #2 Device 1 1,060.40' 24.0"Horiz.Orifice/Grate C=0.600 Limited to weir flow at low heads #3 Discarded 1,059.00' 0.500 in/hr Exfiltration over Surface area from 1,059.00'- 1,060.50' Excluded Surface area = 0.040 ac Phase -In= 0.01' Discarded OutFlow Max=0.12 cfs @ 12.67 hrs HW=1,060.50' (Free Discharge) t--3--Exfiltration (Exfiltration Controls 0.12 cfs) Prirnary OutFlow Max=1.88 cfs @ 13.01 hrs HW=1,060.60' TW=1,043.38' (Dynamic Tailwater) t--I=Culvert (Passes 1.88 cfs of 16.54 cfs potential flow) t--2=Orifice/Grate (Weir Controls 1.88 cfs @ 1.47 fps) IVIMW Exist Pond 2003 Design 8-28-15 Type I/ 24 -hr 10 year Rainfall=4.15" Prepared by Microsoft Printed 9/8/2015 HydroCAD@)10.00-12 s/nO6O27 @2014 HydroCAD Software Solutions LLC Page 25 F Pond 1P: East Filtration Swale Hydrograph Tim j1houm) 0 Inflm L] Outfim 0 Dismrded 0 Pnmary MMW Exist Pond 2003 Design B-28-1 5 Type // 24 -hr 10 year Rainfall=4.15" Prepared by Microsoft Printed 9/8/2015 HydroCAD@10.00-12 s/n06027 @2014 HydroCAD Software Solutions LLC Page 26 Summary for Pond 2P: West Filtration Swale [93] Warning: Storage range exceeded by 0.64' [90] Warning: Qout>Qin may require smaller dt or Finer Routing [871 Warning: Oscillations may require smaller dt or Finer Routing (severity --121) Inflow Area 0.813 ac, 66.17% Impervious, Inflow Depth = 2.59" for 10 year event Inflow 1.80 cfs @ 12.24 hrs, Volume= 0.176 af Outflow 3.15 cfs @ 12.25 hrs, Volume= 0.176 af, Atten= 0%, Lag= 0.4 min Discarded 0.04 cfs @ 12.25 hrs, Volume= 0.073 af Primary 3.12 cfs @ 12.25 hrs, Volume= 0.103 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,051.64'@ 12.25 hrs Surf.Area= 0.082 ac Storage= 0.038 af Plug -Flow detention time= 247.5 min calculated for 0.176 af (100% of inflow) Center -of -Mass det. time= 247.7 min ( 1,082.4 - 834.7 ) Volume Invert Avail.Storage Storage Description #1 1,050.00' 0.038 af Custom Stage Data (Prismatic) Listed below (Recalc) Elevation SurfArea Inc.Store Cum.Store (feet) (acres) (acre-feet) (acre-feet) 1,050.00 0.018 0.000 0.000 1,050.50 0.027 0.011 0.011 1,051.00 0.082 0.027 0.038 Device Routing Invert Outlet Devices #1 Primary 1,046.50' 12.0" Round Culvert L= 30.0' RCP, mitered to conform to fill, Ke= 0.700 Inlet/ Outlet Invert= 1,046.50'/ 1,046.00' S=0.0167? Cc=0.900 n=0.010 PVC, smooth interior, FlowArea=0.79sf #2 Device 1 1,050.90' 24.0" Vert. Orifice/Grate C= 0.600 #3 Discarded 1,050.00' 0.500 in/hr Exfiltration over Horizontal area from 1,049.W - 1,050.90' Conductivity to Groundwater Elevation = 0.00' Excluded Horizontal area = 0.000 ac Phase -In= 0.01' Discarded OutFlow Max=0.04 ds @ 12.25 hrs HW=1,051.64' (Free Discharge) 't-3=Exfiltration ( Controls 0.04 afs) Primary OutFlow Max=3.11 cfs @ 12.25 hrs HW=1,051.64' TW=1,042.or (Dynamic Tailwater) '�—J=Culvert (Passes 3.11 cfs of 7.19 cfs potential flow) 't-2=Orifice/Grate (Orifice Controls 3.11 ds @ 2.93 fps) MMW Exist Pond 2003 Design 8-28-15 Type // 24 -hr 10 year Rainfall=4.15" Prepared by Microsoft Printed 9/8/2015 HydroCAD@10.00-12 s/nO6027 @2014 HydroCAD Software Solutions LLC Paae 27 Pond 2P: West Filtration Swale Hydrograph Ti� (houm) 0 Infim E outfim N Di�rded N Pnmary MMW Exist Pond 2003 Design 8-28-15 Type 1/ 24 -hr 10 year Raintail=4.15" Prepared by Microsoft Printed 9/8/2015 HydroCAD@ 10.00-12 s1n 06027 @ 2014 HydroCAD Software Solutions LLC Paae 28 Summary for Pond 3P: Det Pond [80) Warning: Exceeded Pond 1 by 1.81'@ 24.62 hrs (10.08 ds 5.340 af) Inflow Area 14.034 ac, 24.54% Impervious, Inflow Depth = 1.12" for 10 year event Inflow 15.30 cfs @ 12.03 hrs, Volume= 1.312 af Outflow 0.36 cfs @ 21.07 hrs, Volume= 0.272 af, Atten= 98%, Lag= 542.7 min Discarded 0.03 cfs @ 21.07 hrs, Volume= 0.147 af Primary 0.33 cfs @ 21.07 hrs, Volume= 0.125 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,045.50'@ 21.07 hrs Surf.Area= 0.305 ac Storage= 1.171 af Plug -Flow detention time= 1,268.8 min calculated for 0.272 af (21 % of inflow) Center -of -Mass det. time= 1,111.4 min ( 1,982.9 - 871.4 ) Volume Invert Avail.Storage Storage Description #1 1,034.00' 1.327 af Custom Stage Data (Prismatic) Listed below (Reca1c) Elevation Surf.Area Inc.Store Cum.Store (feet) (acres) (acre-feet) (acre-feet) 1,034.00 0.005 0.000 0.000 1,035.00 0.010 0.008 0.008 1,036.00 0.017 0.013 0.021 1,037.00 0.027 0.022 0.043 1,038.00 0.040 0.033 0.077 1,039.00 0.055 0.048 0.124 1,040.00 0.073 0.064 0.188 1,041.00 0.095 0.084 0.272 1,042.00 0.122 0.109 0.381 1,043.00 0.183 0.152 0.533 1,044.00 0.254 0.219 0.752 1,045.00 0.287 0.270 1.022 1,046.00 0.323 0.305 1.327 Device Routing Invert Outlet Devices #1 Primary 1,043.64' 18.0" Round Surface Outlet L= 50.0' RCP, mitered to conform to fill, Ke= 0.700 Inlet/ Outlet Invert= 1,043.64'/ 1,043.20' S=0.0088'P Cc=0.900 n= 0.015 Concrete, trowel finish, Flow Area= 1.77 sf #2 Device 1 1,045.44' 24.0"Horiz.Orifice/Grate C=0.600 Limited to weir flow at low heads #3 Discarded 1,034.00' 0.100 iriffir Exfiltration over Surface area Conductivity to Groundwater Elevation = 0.00' Phase -In= 0.01' Discarded OutFlow Max=0.03 cfs @ 21.07 hrs HW=1,045.50' (Free Discharge) t--3--Exfiltration ( Controls 0.03 ds) Primary OutFlow Max=0.33 ds @ 21.07 hrs HW=1,045.50' (Free Discharge) t--I=Surface Outlet (Passes 0.33 cfs of 7.92 efs potential flow) t--2=Orifice/Grate (Weir Controls 0.33 Gfs @ 0.82 fps) MMW Exist Pond 2003 Design 8-28-15 Type // 24 -hr 10 year Rainfall=4.15" Prepared by Microsoft Printed 9/8/2015 HydroCAD@)10.OG-12 stnO6O27 @2014 HydroCAD Software SolutonsLLC Page 29 Pond 3P: Det Pond Hydrograph 0.36 ds 0 2 4 6 8 10 12 14 16 18202224262830323436384042444648 505254 56586062646668 70 72 Tim (houm) 'M 'tflm Inflow Area=14.034 ac i�rded Peak Elev=1,045.50' Storage=1.171 af 0 2 4 6 8 10 12 14 16 18202224262830323436384042444648 505254 56586062646668 70 72 Tim (houm) MMW Exist Pond 2003 Design 8-28-15 Type // 24 -hr 100 year Rainfall=5.90" Prepared by Microsoft Printed 9/8/2015 HydroCAD810.00-12 s/n06O27 Q2014 HydroCAD Software Solutions LLC Pace 30 Time span=0.00-72.00 hrs, dt=0,01 hrs, 7201 points Runoff by SCS TR -20 method, UH=SCS, Weighted -CN Reach routing by Dyn-Stor-Ind method - Pond routing by Dyn-Stor-Ind method Subcatchment Al: East Grass Fields & Tennis Runoff Area=6.467 ac 10.65% Impervious Runoff Depth=2.28" Flow Length=400' Tc=45.0 min CN=65 Runoff=9.30 cfs 1.228 af Subcatchment Al 1: Det Pond Runoff Area=0.794 ac 31.99% Impervious Runoff Depth=1.69" Flow Length=100' Tc=6.3 min CN=58 Runoff=2.33 cfs 0.112 af Subcatchment A2: West Grass & Tennis Courts Runoff Area=0.813 ac 66.17% Impervious Runoff Depth=4.21" Flow Length=600' Tc=30.6 min CN=85 Runoff=2.90 cfs 0.285 af Subcatchnnent A3: Main Parking Lot Runoff Area=5.960 ac 32.94% Impervious Runoff Depth=3.01" Flow Length=350' Tc=10.8 min CN=73 Runoff=26.83 cfs 1.493 af Pond 1: Peak Elev--1,047.86' Inflow=26.83 cfs 1.493 af 24.0" Round Culvert n=0.01 5 L=35.0' S=-0.0049'/' Oufflow=26.83 cfs 1.493 af Pond IP: East Filtration Swale Peak Elev--1,060,87' Storage=0.290 af Inflow=9.30 cfs 1.228 af Discarded=O. 12 cfs 0.247 af Primary --6.72 cfs 0.965 af Ouff low=6.84 cfs 1.211 af Pond 2P: West Filtration Swale Peak Elev--1,051.64' Storage=0.038 af Inflow=2.90 cfs 0.285 af Disr-arded=0.04 cfs 0.078 af Primary --3.06 cfs 0.207 af Outflow=3.10 cfs 0.285 af Pond 3P: Det Pond Peak Elev--1,045.94' Storage=1.308 af Inflow=30.54 cfs 2.777 af Discarded=0.03 cfs 0.150 af Primary --7.29 cfs 1.585 af Outflow=7.32 cfs 1.736 af Total Runoff Area = 14.034 ac Runoff Volume = 3.118 af Average Runoff Depth = 2.67" 75.46% Pervious = 10.590 ac 24.54% Impervious = 3.444 ac MMW Exist Pond 2003 Design 8-28-15 Type // 24 -hr 100 year Rainfafl=5.90" Prepared by Microsoft Printed 9/8/2015 HydroCAD@)10.00-12 stnO6027 @2014 HvdroCAD Software Solutionsl-LC Pane 31 Summary for Subcatchment Al: East Grass Fields & Tennis Cts Runoff 9.30 cfs @ 12.45 hrs, Volume= 1.228 af, Depth= 2.28" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr 100 year Rainfall=5.90" Area (ac) CN DescriDtion 5.778 61 >75% Grass cover, Good, HSG B 0.689 98 Path 6.467 65 Weighted Average 5.778 89.35% Pervious Area 0.689 10.65% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (GfS) 43.6 300 0.0150 0.11 Sheet Flow, Existing grass play field Tc=45.0 min CN=65 Grass: Dense n= 0.240 P2= 2.50" 1.4 100 0.0200 1.22 Sheet Flow, Paved Path Smoothsurfaces n=0.011 P2=2.50" 45.0 400 Total Subcatchment Al: East Grass Fields & Tennis Cts Hydrograph Wo 0 Op"T 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 i6 38 �O 42 44 46 48 50 52 �4 �6 �8 60 62 ii4 66 68 70 72 Tim (houm) Type 11 24 -hr 100 year Rainfall=5.90" Runoff Area=6.467 ac Runoff Volume=1.228 af Runoff Depth=2.28" Flow Length=400' Tc=45.0 min CN=65 0 Op"T 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 i6 38 �O 42 44 46 48 50 52 �4 �6 �8 60 62 ii4 66 68 70 72 Tim (houm) MMW Exist Pond 2003 Design 8-28-15 Type 11 24 -hr 100 year Rainfall=5.90" Prepared by Microsoft Printed 902015 HydroCADO 10.00-12 stn 06027 @ 2014 HydroCAD Software Soldons LLC Pane 32 Summary for Subcatchment All: Dot Pond Runoff 2.33cfs@ 11.99hrs, Volume= 0.112af, Depth= 1.69" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr 100 year Rainfall=5.90" Area (ac) CN DeSCriDtion 0.254 98 Pond 0.540 39 >75% Grass cover, Good, HSG A 0.794 58 Weighted Average 0.540 68.01 % Pervious Area 0.254 31.99% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (fuft) (fusec) (cfs) 1.4 50 0.0050 0.61 Sheet Flow, Minnetonka HS Smoothsurfaces n=0.011 P2=2.50" 4.9 50 0.1000 0.17 Sheet Flow, Grass: Dense n= 0.240 P2= 2.50" 6.3 100 Total Subcatchment All: Det Pond Hydrograph Type 11 24 -hr 21 1 0 100 year Rainfall=5.90" Runoff Area=0.794 ac Runoff Volume=0.112 af Runoff Depth=1.69" Flow Length=1 00' 11 1 0 Tc=6.3 min CN=58 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 Tim (houm) MMW Exist Pond 2003 Design 8-28-15 Type /I 24 -hr 100 year Rainfall=5.90" Prepared by Microsoft Printed 9/8/2015 HydroCAD@)10.00-12 s/n06O27 @2014 HydroCAD Software Solutions LLC Paae 33 Summary for Subcatchment A2: West Grass & Tennis Courts Runoff 2.90 Gfs @ 12.24 hrs, Volume= 0.285 af, Depth= 4.21" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr 100 year Rainfall=5.90" Area (ac) CN DescriDtion 0.538 98 Path 0.275 61 >75% Grass cover, Good, HSG B 0.813 85 Weighted Average 0.275 33.83% Pervious Area 0.538 66.17% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ftfft) (ft/sec) (cfs) 3.7 300 0.0150 1.35 Sheet Flow, MinnLtonka HIS Smoothsurfaces n=0.011 P2=2.50" 26.9 300 0.0500 0.19 Sheet Flow, West Grass Grass: Dense n= 0.240 P2= 2.50" 30.6 600 Total Subcatchment A2: West Grass & Tennis Courts Hydrograph Type 11 24 -hr 100 year Rainfall=5.90" 0 Me If -.TT- M-iklbl M -f! 21 1 Runoff Volume=0.285 af Runoff Depth=4.21 Flow Length=600' Tc=30.6 min 'I � I CN=85 0 . . . "W 0 2 4 10 12 14 16 18 iO 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Tim (houm) MMW Exist Pond 2003 Design 8-28-15 Type // 24 -hr 100 year Rainfall=5-90" Prepared by Microsoft Printed 902015 HydroCAD010.00-12 s/nO6027 (92014 HydroCAD Software Solutions LLC Page 34 Sumniary for Subcatchnient Al Main Parking Lot Runoff 26.83 cfs @ 12.03 hrs, Volume= 1.493af, Depth= 3.01" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr 100 year Rainfall=5.90" Area (ac) CIN 1.963 98 Parking Lot 3.997 61 >75% Grass cover, Good, HSG B 5.960 73 Weighted Average 3.997 67.06% Pervious Area 1.963 32.94% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (fVft) (ft/sec) (cfs) 4.4 300 0.0100 1.15 Sheet Flow, Minnetonka HS Smoothsurfaces n=0.011 P2=2.50" 6.4 50 0.0200 0.13 Sheet Flow, Grass:Short n=0.150 P2=2.50" 10.8 350 Total Subcatchment Al Main Parking Lot Hydrograph 26� Type 11 24 -hr 24 100 year Rainfall=5.90" 22 Runoff Area=5.960 ac 20� 18- Runoff Volume=1.493 af �e 16 Runoff Depth=3.01" 14 Flow Length=350' 12 10 Tc=10.8 min 8 1 CN=73 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 nm (houm) WIMW Exist Pond 2003 Design 8-28-15 Type /I 24 -hr 100 year Rainfall=5.90" Prepared by Microsoft Printed 9/812015 HydroCAD010.00-12 s1n06027 02014 HydroCAD Software Solutions LLC Page 35 Summary for Pond 1: [571 Hint: Peaked at 1,047.86'(Flood elevation advised) Inflow Area 5.960 ac, 32.94% Impervious, Inflow Depth = 3.01" for 100 year event Inflow 26.83 Gfs @ 12.03 hrs, Volume= 1.493 af Outflow 26.83 Gfs @ 12.03 hrs, Volume= 1.493 af, Atten= 0%, Lag= 0.0 min Primary 26.83 Gfs @ 12.03 firs, Volume= 1.493 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,047.86'@ 12.03 firs Device Routing Invert Outlet Devices #1 Primary 1,043.67' 24.0" Round Culvert L= 35.0' RCP, sq.cut end projecting, Ke= 0.500 Inlet/ Outlet Invert= 1,043.50'/ 1,043.67' S=-0.0049? Cc=0.900 n= 0.015 Concrete sewer w/manholes & inlets, Flow Area= 3.14 sf Primary OutFlow Max=26.80 cfs @ 12.03 hrs HW=1,047.85' TW=1,042.76' (Dynamic Tailwater) '�—1 =Culvert (Barrel Controls 26.80 ds @ 8.53 fps) Pond 1: Hydrograph a Inflow Area=5.960 ac t�j 241 1 W Peak Elev=1,047.86' 22� 24.011 20� 18� Round Culvert a 16� n=0.015 14- 12� L=35.0' 10 S=-0.00497' 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 4( Tim (houm) MMW E)dst Pond 2003 Design 8-28-15 Type il 24 -hr 100 year Rainfail=5.90" Prepared by Microsoft Printed 9/8/2015 HydroCAD@) 10.00-12 s/n 06027 @ 2014 HydroCAD Software Solutions LLC Page 36 Summary for Pond 1P: East Filtration Swale Inflow Area 6.467 ac, 10.65% Impervious, Inflow Depth = 2.28" for 100 year event Inflow 9.30 cfs @ 12.45 hrs, Volume= 1.228 af Outflow 6.84 cfs @ 12.73 hrs, Volume= 1.211 af, Atten= 26%, Lag= 16.7 min Discarded 0.12 cfs @ 12.33 hrs, Volume= 0.247 af Primary 6.72 cfs @ 12.73 hrs, Volume= 0.965 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,060.87'@ 12.73 hrs Surf.Area= 0.403 ac Storage= 0.290 af Plug -Flow detention time= 198.1 min calculated for 1.211 af (99% of inflow) Center -of -Mass det. time= 190.4 min ( 1,074.3 - 883.9 ) Volume I nvert Avail.Storaqe Storage Description #1 1,059.00' 0.343 af Custom Stage Data (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (acres) (acre-feet) (acre-feet) 1,059.00 0.040 0.000 0.000 1,060.00 0.100 0.070 0.070 1,061.00 0.447 0.273 0.343 Device Routing Invert Outlet Devices #1 Primary 1,055.00' 18.0" Round Culvert L= 140.0' RCP, mitered to conform to fill, Ke= 0.700 Inlet/ Outlet Invert= 1,055.00'/ 1,046.00' S=0.0643P Cc=0.900 n=0.010 PVC, smooth interior, FlowArea=1.77sf #2 Device 1 1,060.40' 24.0"Horiz.OrificelGrate C=0.600 Limited to weir flow at low heads #3 Discarded 1,059.00' 0.500 in/hr Exhitration over Surface area from 1,059.00'- 1,060.W Excluded Surface area = 0.040 ac Phase -In= 0.01' Discarded OutFlow Max=0.12 cfs @ 12.33 hrs HW=1,060.52' (Free Discharge) '�-3--Exfiltration (Exfiltration Controls O.12Gfs) Primary OutFlow Max=6.72 cl's @ 12.73 hrs HW=1,060.8r TW=1,045.66' (Dynamic Tailwater) t -1 --Culvert (Passes 6.72 cfs of 17.00 cfs potential flow) 't-2=0rifice/Grate (Weir Controls 6.72 efs @ 2.25 fps) MMW Exist Pond 2003 Design 8-28-15 Type // 24 -hr 100 year Rainfall=5.90" Prepared by Microsoft Printed 9/8/2015 HydroCAD010.00-12 s/nO6O27 @2014 HydroCAD Software Solutions LLC Paae 37 1 Pond 1P: East Filtration Swale Hydrograph 0 Infim 9.3 E Outfim 13 Di�rded Inflow Area=6.467 ac 0 Pnmary 684cpPeak Elev=l 060.87' is Storage=0.290 af 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 Tim (houm) MMW Exist Pond 2003 Design 8-28-15 Type 11 24 -hr 100 year Rainfail=5.90" Prepared by Microsoft Printed 902015 HydroCAD@ 10.00-12 s1n 06027 C 2014 HydroCAD Software Solutions LLC Paae 38 Summary for Pond 2P: West Filtration Swale [931 Warning: Storage range exceeded by 0.64' [90] Warning: QoLft>Qin may require smaller dt or Finer Routing [87] Warning: Oscillations may require smaller dt or Finer Routing (severity --217) Inflow Area 0.813ac, 66.17% Impervious, lnflowDepth= 4.21" for 100yearevent Inflow 2.90ds@ 12.24hrs, Volume= 0.285 af Outflow 3.10 cfs @ 12.25 hrs, Volume= 0.285 af, Atten= 0%, Lag= 0.5 min Discarded 0.04 cfs @ 12.25 hrs, Volume= 0.078 af Primary 3.06 cfs @ 12.25 hrs, Volume= 0.207 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,051.64'@ 12.25 hrs Surf.Area= 0.082 ac Storage= 0.038 af Plug -Flow detention time= 167.1 min calculated for 0.285 af (100% of inflow) Center -of -Mass det. time= 167.3 min ( 988.3 - 821.0 ) Volume Invert Avail.Storaqe Storage Description #1 1,050.00' 0.038 af Custom Stage Data (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (acres) (acre-feet) (acre-feet) 1,050.00 0.018 0.000 0.000 1,050.50 0.027 0.011 0.011 1,051.00 0.082 0.027 0.038 Device Routing Invert Outlet Devices #1 Primary 1,046.50' 12.0" Round Culvert L= 30.0' RCP, mitered to conform to fill, Ke= 0.700 Inlet/ Outlet Invert= 1,046.50'/ 1,046.00' S=0.0167T Cc=0.900 n=0.010 PVC, smooth interior, FlowArea=0.79sf #2 Device 1 1,050.90' 24.0" Vert. Orifice/Grate C= 0.600 #3 Discarded 1,050.00' 0.500 in/hr Exfiltration over Horizontal area from 1,049.00'- 1,060.90' Conductivity to Groundwater Elevation = 0.00' Excluded Horizontal area = 0.000 ac Phase -In= 0.01' Discarded OutFlow Max=0.04 ds @ 12.25 hrs HW=1,051.64' (Free Discharge) '�-3--Exfiltration ( Controls 0.04 cfs) Primary OutFlow Max=3.06 ds @ 12.25 hrs HW=1,051.64' TW=1,044.35' (Dynamic Tailwater) t--l=Culvert (Passes 3.06 cfs of 7.18 cfs potential flow) t--2=0rifice/Grate (Orifice Controls 3.06 efs @ 2.92 fps) MMW Exist Pond 2003 Design 8-28-15 Type // 24 -hr 100 year Rainfall=5.90" Prepared by Microsoft Printed 9/812015 HydroCAD010.013-12 stnO6O27 @2014 HydroCAD Software Solubons LLC Page 39 Pond 2P: West Filtration Swale Hydrograph N Inflm E Outf1m 3.10 cis 0 Ois�rded Inflow Area=CI.813 ac 0 Pnmafy Peak Elev=1,051.64' a Storage=0.038 af 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 3638 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 iO 72 Tim (houm) MMW Exist Pond 2003 Design B-28-15 Type I/ 24 -hr 100 year Rainfall=5.90" Prepared by Microsoft Printed 9/8/2015 HydroCAD@10.00-12 s1n06027 (92014 HydroCAD Software Solutions LLC Page 40 Summary for Pond 3P: Det Pond [80] Warning: Exceeded Pond 1 by 1.84' @ 24.52 hrs (10.32 cfs 6.846 af) Inflow Area 14.034 ac, 24.54% Impervious, Inflow Depth = 2.37" for 100 year event Inflow 30.54 cfs @ 12.03 hrs, Volume= 2.777 af outflow 7.32 cfs @ 13.08 hrs, Volume= 1.736 af, Atten= 76%, Lag= 63.1 min Discarded 0.03 cfs @ 13.08 hrs, Volume= 0.150 af Primary 7.29 cfs @ 13.08 hrs, Volume= 1.585 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,045.94'@ 13.08 hrs Surf.Area= 0.321 ac Storage= 1.308 af Plug -Flow detention time= 359.2 min calculated for 1.736 af (63% of inflow) Center -of -Mass det. time= 245.6 min ( 1,102.0 - 856.4 ) Volume Invert Avail.Storage Storage Description #1 1,034.00- 1.327 af Custom Stage Data (Prismatic) Listed below (Reca1c) Elevation Surf.Area Inc.Store Cum.Store (feet) (acres) (acre-feet) (acre-feet) 1,034.00 0.005 0.000 0.000 1,035.00 0.010 0.008 0.008 1,036.00 0.017 0.013 0.021 1,037.00 0.027 0.022 0.043 1,038.00 0.040 0.033 0.077 1,039.00 0.055 0.048 0.124 1,040.00 0.073 0.064 0.188 1,041.00 0.095 0.084 0.272 1,042.00 0.122 0.109 0.381 1,043.00 0.183 0.152 0.533 1,044.00 0.254 0.219 0.752 1,045.00 0.287 0.270 1.022 1,046.00 0.323 0.305 1.327 Device Routing Invert Outlet Devices #1 Primary 1,043.64' 18.0" Round Surface Outlet L= 50.0' RCP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 1,043.64'/ 1,043.20' S= 0.0088? Cc= 0.900 n= 0.015 Concrete, trowel finish, Flow Area= 1.77 sf #2 Device 1 1,045.44' 24.0"Horiz-Orifice/Grate C=0.600 Limited to weir flow at low heads #3 Discarded 1,034.00' 0.100 in/hr Exfiltration over Surface area Conductivity to Groundwater Elevation = 0.00' Phase -In= 0.01' Discarded OutFlow Max=0.03 cfs @ 13.08 hrs HW=1,045.94' (Free Discharge) 't-3--Exfiltration ( Controls 0.03 cfs) Primary OutFlow Max=7.29 cfs @ 13.08 hrs HW=1,045.94' (Free Discharge) 't-1 =Surface Outlet (Passes 7.29 cfs of 9.25 cfs potential flow) t--2--OriflcefGrate (Weir Controls 7.29 ds @ 2.32 fps) MMW Exist Pond 2003 Design 8-28-15 Prepared by Microsoft HydroCADO 10.00-12 stn 06027 @ 2014 HydroC, Pond 3P: Det Pond Hydrograph zu 18 16 14 121 7.32 Type // 24 -hr 100 year Rainfa#=5.90" Printed 9/8/2015 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 " 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Tim jhoum) tn. Inflow Area=141.034 ac zrded Peak Elev=1,045.941 Storage=1.308 af 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 " 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Tim jhoum) MMW Exist Pond 2003 Design 8-28-15 Type// 24 -hr Abstraction Rainfall= 1. 10" Prepared by Microsoft Printed 9/8/2015 HydroCADE)10.00-12 s/nO6O27 @2014 HydroCAD Software Solutions LLC Page 42 Time span=0.00-72.00 hrs, dt=0.01 hrs, 7201 points Runoff by SCS TR -20 method, UH=SCS, Weighted -CN Reach routing by Dyn-Stor-Ind method - Pond routing by Dyn-Stor-Ind method Subcatchment Al: East Grass Fields & Tennis Runoff Area=6.467 ac 10.65% Impervious Runoff Depth=0.00" Flow Length=400' Tc=45.0 min CN=65 Runoff=0.00 cfs 0.000 af Subcatchment All: Det Pond Runoff Area=0.794 ac 31.99% Impervious Runoff Depth=0.00" Flow Length=100' Tc=6.3 min CN=58 Runoff=0.00 cl's 0.000 af Subcatchment A2: West Grass & Tennis Courts Runoff Area=0.813 ac 66.17% Impervious Runoff Depth=0.22" Flow Length=600' Tc=30.6 min CN=85 Runoff=0.12 cfs 0.015 af Subcatchnnent A3: Main Parking Lot Runoff Area=5.960 ac 32.94% Impervious Runoff Depth=0.03" Flow Length=350' Tc=10.8 min CN=73 Runoff=0.02 cfs 0.016 af Pond 1: Peak Elev--1,043.73' Inflow=0.02cfs 0.016af 24.0" Round Culvert n=0.015 L=35.0' S= -0.0049'P Oufflow=0.02cfs 0.016af Pond 1P: East Filtration Swale Peak Elev--1,059.00' Storage=0.000 af Inflow=0.00 cfs 0.000 af Discarded=0.00 cfs 0.000 af Primary --0.00 cfs 0.000 af Oufflow=0.00 cfs 0.000 af Pond 2P: West Filtration Swale Peak Elev--1,050.32' Storage=0,007 af Inflow=0.12 cfs 0.015 af Discarded=0.01 cfs 0.015 af Primary --0.00 cfs 0.000 af Oufflow=0.01 cfs 0.015 af Pond 3P: Det Pond Peak Elev--1,035.60' Storage=0.01 5 af lnflow=0.02 cfs 0.016 af Discarded=0.00 efs 0.006 af Primary --0.00 cfs 0.000 af Oufflow=0.00 cfs 0.006 af Total Runoff Area = 14.034 ac Runoff Volume = 0.031 af Average Runoff Depth = 0.03" 75.46% Pervious = 10.590 ac 24.54% Impervious = 3.444 ac MMW Exist Pond 2003 Design 8-28-15 Prepared by Microsoft Type il 24 -hr Abstraction Rainfall=l. 10" Printed 9/8/2015 Summary for Subcatchment Al: East Grass Fields & Tennis Cts Runoff 0.00 cfs @ 24.25 hrs, Volume= 0.000af, Depth= 0.00" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr Abstraction Rainfall=11.10" Area (ac) CINI DescriDtion 5.778 61 >75% Grass cover, Good, HSG B 0.689 98 Path 6.467 65 Weighted Average 5.778 89.36% Pervious Area 0.689 10.65% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (fVft) (ft/sec) (ds) 43.6 300 0.0150 0.11 Sheet Flow, Existing grass play field 0.000�1 Grass: Dense n= 0.240 P2= 2.50" 1.4 100 0.0200 1.22 Sheet Flow, Paved Path Tc=45.0 min 0.000 Smoothsurfaces n=0.011 P2=2.50" 45.0 400 Total Subcatchment All: East Grass Fields & Tennis Cts Hydrograph 0.001 0.001- Type 11 24 -hr 0.000- Abstraction Rainfall=1.10" 0.000- Runoff Area=6.467 ac 0.000- Runoff Volume=0.000 af 1 Runoff Depth=0.00" 0.000�1 Flow Length=400' 0.000 Tc=45.0 min 0.000 CN=65 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 Tim (houm) MMW Exist Pond 2003 Design 8-28-15 Type // 24 -hr Abstraction Rainfall=l. 10" Prepared by Microsoft Printed 9/812015 HydroCADO 10.00-12 s1n 06027 C 2014 HydroCAD Software Solutions LLC Page 44 Summary for Subcatchment Al 1: Det Pond [45] Hint: Runoff=Zero Runoff 0.00 cfs @ 0.00 hrs, Volume= 0.000 af, Depth= 0.00" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr Abstraction Rainfall=1.10" Area (ac) CN 0.254 98 Pond 0.540 39 >75% Grass cover, Good, HSG A 0.794 58 Weighted Average 0.540 68.01% Pervious Area 0.254 31.99% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 1.4 50 0.0050 0.61 Sheet Flow, Minnetonka HS Smoothsurfaces n=0.011 P2=2.50" 4.9 50 0.1000 0.17 Sheet Flow, Grass: Dense n= 0.240 P2= 2.50" 6.3 100 Total Subcatchment All: Det Pond Hydrograph Type ll 24 -hr Abstraction Rainfall=1.10" Runoff Area=0.794 ac Runoff Volume=0.000 af Runoff Depth=0.00" Flow Length=100' Tc=6.3 min CN=58 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Tim fhoum) MMW Exist Pond 2003 Design 8-28-15 Prepared by Microsoft Type// 24 -hr Abstraction Rainfaft 1. 10" Summary for Subcatchment A2: West Grass & Tennis Courts Runoff 0.12cfs@ 12.30hrs, Volume= 0.015 af, Depth= 0.22" Printed 9/812015 Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr Abstraction Rainfall=11.1 0" Area (ac) CN DescriDtion 0.538 98 Path 0.275 61 >75% Grass cover, Good, HSG B 0.813 85 Weighted Average 0.275 33.83% Pervious Area 0.538 66.17% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (fUft) (fUsec) (ds) 3.7 300 0.0150 1.35 Sheet Flow, Minnetonka HS Smoothsurfaces n=0.011 P2=2.50" 26.9 300 0.0500 0.19 Sheet Flow, West Grass Grass: Dense n= 0.240 P2= 2.50" 30.6 600 Total 0.13 0.12 0.11 0.1 0.01 Subcatchment A2: West Grass & Tennis Courts Hydrograph I 0.12cfs I Type 11 24 -hr Abstraction Rainfall=1.10" Runoff Area=0.813 ac Runoff Volume=0.015 af Runoff Depth=0.22" Flow Length=600' Tc=30.6 min CN=85 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 Tim jhoum) MMW E)dst Pond 2003 Design 8-28-15 Prepared by Microsoft Type// 24 -hr Abstraction Rainfall= 1. 10" Printed 9/812015 Summary for Subcatchment A3: Main Parking Lot Runoff 0.02 cfs @ 13.02 hrs, Volume= 0.016 af, Depth= 0.03" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr Abstraction Rainfall=1.10" Area (ac) CN DescriDtion 1.963 98 Parking Lot 3.997 61 >75% Grass cover, Good, HSG B 5.960 73 Weighted Average 3.997 67.06% Pervious Area 1.963 32.94% Impervious Area Tc Length Description 4.4 300 0.0100 1.15 Sheet Flow, Minnetonka HS Smoothsurfaces n=0.011 P2=2.50" 6.4 50 0.0200 0.13 Sheet Flow, Grass:Short n=0.150 P2=2.50" 10.8 350 Total Subcatchnient A3: Main Parking Lot Hydrograph 0.026 0.024 0.. Type 11 24 -hr 0.022 Abstraction Rainfall=1.10" 0.02 Runoff Area=5.960 ac 0.018 Runoff Volume=0.016 af 0.016- Runoff Depth=0.03" 0.014 Flow Length=350' 0.012- Tc=10.8 min 0.01- nnnA- I CN=73 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 4( Tim (houm) MMW Exist Pond 2003 Design 8-28-15 Type /I 24 -hr Abstraction Raintall=l. 10" Prepared by Microsoft Printed 9/8/2015 HydroCAD@10.00-12 s1n06027 @2014 HydroCAD Software Solutions LLC Pacie 47 Summary for Pond 1: [57] Hint: Peaked at 1,043.73'(Flood elevation advised) Inflow Area 5.960 ac, 32.94% Impervious, Inflow Depth = 0.03" for Abstraction event Inflow 0.02 cfs @ 13.02 hrs, Volume= 0.016 af Outflow 0.02 cfs @ 13.02 hrs, Volume= 0.016 af, Atten= 0%, Lag= 0.0 min Primary 0.02 cfs @ 13.02 hrs, Volume= 0.016 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,043.73'@ 13.02 hrs Device Routing Invert Outlet Devices #1 Primary 1,043.67' 24.0" Round Culvert L= 35.0' RCP, sq.cut end projecting, Ke= 0.500 Inlet/ Outlet Invert= 1,043.50'11,043.67' S= -0.0049'P Cc=0.900 n= 0.015 Concrete sewer w/manholes & inlets, Flow Area= 3.14 sf Primary OutFlow Max=0.02 cfs @ 13.02 hrs HW=1,043.73' TW=1,034.22' (Dynamic Tailwater) 't--I=Culvert (Inlet Controls 0.02 cfs @ 0.84 fps) Pond 1: Hydrograph FE —Infl.--1 10 Pnmary Inflow Area=5.960 aC U.W2- Peak Elev=1,043.73' U2. 0.018- 24.011 0.016- Round Culvert 1� OV4, n=0.01 5 1 0.012- L=35.0' 0.01 0008 rs S=-0.00497' 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Tim Jhoum) MMW Exist Pond 2003 Design 8-28-15 Type 11 24 -hr Abstraction Rainfall= 1. 10" Prepared by Microsoft Printed 9/8/2015 HydroCAD010.00-12 s1n06027 (92014 HydroCAD Software Solutions LLC Page 48 Summary for Pond 11P: East Filtration Swale Inflow Area 6.467 ac, 10.65% Impervious, Inflow Depth = 0.00" for Abstraction event Inflow 0.00 cfs @ 24.25 hrs, Volume= 0.000 af Outflow 0.00 efs @ 25.84 hrs, Volume= 0.000 af, Aften= 99%, Lag= 95.5 min Discarded 0.00 efs @ 25.84 hrs, Volume= 0.000 af Primary 0.00 cfs @ 0.00 hrs, Volume= 0.000 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,059.00'@ 25.84 hrs Surf.Area=0.040ac Storage=0.000af Plug -Flow detention time= 1,329.6 min calculated for 0.000 af (28% of inflow) Center -of -Mass det. time= 1,289.5 min ( 2,733.8 - 1,444.3 ) Volume Invert Avail.Storage Storage Description #1 1,059.00' 0.343af Custom Stage Data (Prismatic) Listed below (Recalc) Elevation SurfArea Inc.Store Cum.Store (feet) (acres) (acre-feet) (acre-feet) 1,059.00 0.040 0.000 0.000 1,060.00 0.100 0.070 0.070 1,061.00 0.447 0.273 0.343 Device Routing Invert Outlet Devices #1 Primary 1,055.00' 18.0" Round Culvert L= 140.0' RCP, mitered to conform to fill, Ke= 0.700 Inlet/ Outlet Invert= 1,055.00'/ 1,046.00' S=0.0643'P Cc=0.900 n=0.010 PVC, smooth interior, FlowArea=1.77sf #2 Device 1 1,060.40' 24.0"Horiz.Orifice/Grate C=0.600 Limited to weir flow at low heads #3 Discarded 1,059.00' 0.500 in/hr Exfiltration over Surface area from 1,059.W - 1,060.50' Excluded Surface area = 0.040 ac Phase -In= 0.01' Discarded OutFlow Max=0.00 ds @ 25.84 hrs HW=1,059.00' (Free Discharge) '�-3=Exfiitration (Exfiltration Controls 0.00 cfs) Primary OutRow Max=0.00 cis @ 0.00 hrs HW=1,059.00' TW=1,034.00' (Dynamic Tailwater) t--l=Culvert (Passes 0.00 cfs of 13.53 cfs potential flow) t--2=Orifice/Grate ( Controls 0.00 cfs) MMW Exist Pond 2003 Design 8-28-15 Prepared by Microsoft HvdroCAE)@ 10.00-12 s/n 06027 @ 2014 HvdroC, Type// 24 -hr Abstraction Rainfall= 1. 10" Printed 9/8/2015 LLC Pond IP: East Filtration Swale Hydrograph T7 0.001 Inflow Area=6.467 ac is� ded 0.001 0.000( Peak Elev=1,059.00 I Storage=0.000 af efs 4 6 8 1012141618202224262830323436384042444648505254565860626466687072 Tim (houm) MMW Exist Pond 2003 Design 8-28-15 Type /I 24 -hr Abstraction Raintall=l. 10" Prepared by Microsoft Printed 9/8/2015 HydroCAD@10.00-12 s/nO6O27 @2014 HydroCAD Software Solutions LLC Page 50 Summary for Pond 2P: West Filtration Swale Inflow Area 0.813 ac, 66.17% Impervious, Inflow Depth = 0.22" for Abstraction event Inflow 0.12 cfs @ 12.30 hrs, Volume= 0.015 af Outflow 0.01 cfs @ 15.41 hrs, Volume= 0.015 af, Atten= 90%, Lag= 186.5 min Discarded 0.01 cfs @ 15.41 hrs, Volume= 0.015 af Primary 0.00 cfs @ 0.00 hrs, Volume= 0.000 af Routing by Dyn-Stor-Ind method, Time Span= O.OG-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,050.32'@ 15.41 hrs Surf.Area= 0.024 ac Storage= 0.007 af Plug -Flow detention time= 287.3 min calculated for 0.015 af (100% of inflow) Center -of -Mass clet. time= 287.3 min ( 1,198.3 - 911.0 ) Volume Invert Avaii.Storage Storage Description #1 1,050.00, 0.038 af Custom Stage Data (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (acres) (acre-feet) (acre-feet) 1,050.00 0.018 0.000 0.000 1,050.50 0.027 0.011 0.011 1,051.00 0.082 0.027 0.038 Device Routing Invert Outlet Devices #1 Primary 1,046.50' 12.0" Round Culvert L= 30.0' RCP, mitered to conform to fill, Ke= 0.700 Inlet/ Outlet Invert= 1,046.50'/ 1,046.00' S=0.0167P Cc=0.900 n= 0.010 PVC, smooth interior, Flow Area= 0.79 sf #2 Device 1 1,050.90' 24.0" Vert. Orifice/Grate C= 0.600 #3 Discarded 1,050.00' 0.500 in/hr Exfiltration over Horizontal area from 1,049.00'- 1,050.90' Conductivity to Groundwater Elevation = 0.00' Excluded Horizontal area = 0.000 ac Phase -In= 0.01' Discarded OutFlow Max=0.01 cfs @ 15.41 hrs HW=1,050.32' (Free Discharge) 't-3--Exfiltration ( Controls 0.01 Gfs) Primary OutRow Max=0.00 cis @ 0.00 hrs HW=1,050.00' TW=1,034.00' (Dynamic Tailwater) t—I=Culvert (Passes 0.00 cfs of 5.78 cfs potential flow) '�-2=Orifice/Grate (Controls 0.00 Gfs) MMW Exist Pond 2003 Design 8-28-15 Type// 24 -hr Abstraction Rainfafi= 1. 10" Prepared by Microsoft Printed 9/8/2015 HydroCAD@)10.00-12 s/nO6027 @2014 HydroCAD Software Solutons LLC Page 51 OA 0.02 Pond 2P: West Filtration Swale Hydrograph 0 2 4 6 8 1012141618202224262830323436384042444648505254565860626466687072 Tim jhoum) 0 Infim L] Outflm Inflow Area=CI.813 ac E Di�rded 0 Primary Peak Elev=1,050.32' Storage=0.007 af 0 2 4 6 8 1012141618202224262830323436384042444648505254565860626466687072 Tim jhoum) MMW Exist Pond 2003 Design B-28-15 Type /I 24 -hr Abstraction Rainfail=l. 10" Prepared by Microsoft Printed 9/8/2015 HydroCADS10.00-12 s(n06027 @2014 HydroCAD Software Solutions LLC Page 52 Summary for Pond 3P: Det Pond Inflow Area 14.034 ac, 24.54% Impervious, Inflow Depth = 0.01" for Abstraction event Inflow 0.02 cfs @ 13.02 hrs, Volume= 0.016 af Outflow 0.00 Gfs @ 24.26 hrs, Volume= 0.006 af, Atten= 94%, Lag= 674.5 min Discarded 0.00 cfs @ 24.26 hrs, Volume= 0.006 af Primary 0.00 Gfs @ 0.00 hrs, Volume= 0.000 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,035.60'@24.26 hrs Surf.Area=0.014ac Storage=0.015af Plug -Flow detention time= 1,702.9 min calculated for 0.006 af (39% of inflow) Center -of -Mass det. time= 1,493.9 min ( 2,545.0 - 1,051.1 ) Volume Invert Avail.Storaqe Storage Description #1 1,034.00' 1.327 af Custom Stage Data (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (acres) (acre-feet) (acre-feet) 1,034.00 0.005 0.000 0.000 1,035.00 0.010 0.008 0.008 1,036.00 0.017 0.013 0.021 1,037.00 0.027 0.022 0.043 1,038.00 0.040 0.033 0.077 1,039.00 0.055 0.048 0.124 1,040.00 0.073 0.064 0.188 1,041.00 0.095 0.084 0.272 1,042.00 0.122 0.109 0.381 1,043.00 0.183 0.152 0.533 1,044.00 0.254 0.219 0.752 1,045.00 0.287 0.270 1.022 1,046.00 0.323 0.305 1.327 Device Routing Invert Outlet Devices #1 Primary 1,043.64' 18.0" Round Surface Outlet L= 50.0' RCP, mitered to conform to fill, Ke= 0.700 Inlet/ Outlet Invert= 1,043.64'/ 1,043.20' S=0.0088P Cc=0.900 n= 0.015 Concrete, trowel finish, Flow Area= 1.77 sf #2 Device 1 1,045.44' 24.0"Horiz.OrificelGrate C=0.600 Limited to weir flow at low heads #3 Discarded 1,034.00' 0.100 inthr Exfiltration over Surface area Conductivity to Groundwater Elevation = 0.00' Phase -In= 0.01' Discarded OutFlow Max=0.00 ds @ 24.26 hrs HW=1,035.60' (Free Discharge) t-3--Exfittration ( Controls 0.00 cfs) Primary OutFlow Max=0.00 cfs @ 0.00 hrs HW=1,034.00' (Free Discharge) 't-I=Surface Outlet ( Controls 0.00 cfs) t­2=06fice/Grate (Controls 0.00ds) MMW Exist Pond 2003 Design 8-28-15 Type /I 24 -hr Abstraction Rainfall= 1. 10" Prepared by Microsoft Printed 9/8/2015 HydroCAD@)10.00-12 s/n06O27 02014 HydroCAD Software Solutions LLC Page 53 0.006 Pond 3P: Det Pond 10 Inflow k 0 Inflow Area=14.034 ac D=ed 0 Primary Peak Elev=1,035.60' Storage=0.015 af 32 34 3638 4042 44 4648 50 52 5456 5860 6264 66 6870 72 Tim (houm� West Grass & nnis Courts Z2 P West Filtratio JB\ Main Parking Lot � 4 F�� A0 CITY OF CHANHASSEN RECEIVED SEP 0 8 2015 I �HANHASSENRLANNNGDEn Eas Grass Fields& Tennis Cts Z� 1 P Swale - CA4� Proposed New Proposed Parking Lot & Underground Storm Widened Drive Chambers SCANNED MMW North Park Lot Add 9-1 -15 Prepared by Microsoft Printed 9/8/20115 HydroCAD@)10.00-12 stnO6O27 02014 HydroCAD Software Soloons LLC Page 2 Area Listing (all nodes) Area CN Description (acres) (subcatchment-numbers) 10.383 61 >75% Grass cover, Good, HSG B (Al, A2, A3, A4) 2.719 98 Parking Lot (A3, A4) 0.600 98 Path (A2) 0.689 98 Paved parking, HSG A (Al) 14.391 71 TOTAL AREA MMW North Park Lot Add 9-1-15 Prepared by Microsoft Printed 9/8/2015 HydroCAD010.00-12 s/n06027 02014 HydroCAD Software Solutions LLC Page 3 Soil Listing (all nodes) Area Soil Subcatchment (acres) Group Numbers 0.689 HSG A At 10.383 HSG 6 A1,A2,A3,A4 0.000 HSG C 0.000 HSG D 3.319 Other A2, A3, A4 14.391 TOTAL AREA MMW North Park Lot Add 9-1-15 Prepared by Microsoft Printed 9/8/2015 HydroCAD@ 10.00-12 s/n 06027 @ 2014 HydroCAD Software Solutions LLC Pacie 4 Ground Covers (all nodes) HSG -A HSG -B HSG -C HSG -D Other Total Ground Subcatchment (acres) (acres) (acres) (acres) (acres) (acres) Cover Numbers 0.000 10.383 0.000 0.000 0.000 10.383 >75% Grass cover, Good Al, A2, A3, A4 0.000 0.000 0.000 0.000 2.719 2.719 Parking Lot A3, A4 0.000 0.000 0.000 0.000 0.600 0.600 Path A2 0.689 0.000 0.000 0.000 0.000 0.689 Paved parking Al 0.689 10.383 0.000 0.000 3.319 14.391 TOTAL AREA MMW North Park Lot Add 9-1-16 Prepared by Microsoft Printed 9/8/2015 HydroCAE)@10.00-12 s/nO6O27 02014 HydroCAD Software SoldonsLLC Page 5 Pipe Listing (all nodes) Line# Node Number In -invert (feet) Out -Invert (feet) Length (feet) Slope (ft/ft) n Diam/Width (inches) Height (inches) Inside -Fill (inches) 1 1 1,043.50 1,043.67 35.0 -0.0049 0.015 24.0 0.0 0.0 2 1 P 1,055.00 1,046.00 140.0 0.0643 0.010 18.0 0.0 0.0 3 213 1,046.50 1,046.00 30.0 0.0167 0.010 12.0 0.0 0.0 4 3P 1,043.00 1,040.00 140.0 0.0214 0.015 18.0 0.0 0.0 MMW North Park Lot Add 9-1-15 Type // 24 -hr I year Rainfall=2.49" Prepared by Microsoft Printed 9/8/2015 HvdroCAD(DlO.00-12 s/n06O27 Q2014 HydroCAD Software Solutions LLC Paqe 6 Time span=0.00-72.00 hrs, dt=0.01 hrs, 7201 points Runoff by SCS TR -20 method, JH=SCS, Weighted -CN Reach routing by Dyn-Stor-Ind method - Pond routing by Dyn-Stor-Ind method Subcatchment All: East Grass Fields & Tennis Runoff Area=6.467 ac 10.65% Impervious Runoff Depth=O 29" Flow Length=400' Tc=45.0 min CN=65 Runoff=0.71 cfs 0. 158 af Subcatchment A2: West Grass & Tennis Courts Runoff Area=0.809 ac 74.17% Impervious Runoff Depth=1 .37" Flow Length=600' Tc=30.6 min CN=88 Runoff=0.95 cfs 0.093 af Subcatchment A3: Main Parking Lot Runoff Area=6.321 ac 33.38% Impervious Runoff Depth=0.56" Flow Length=350' Tc=1 0.8 min CN=73 Runoff=4.83 cfs 0.296 af Subcatchment A4: Proposed Parking Lot & Runoff Area=0.794 ac 76.70% Impervious Runoff Depth=1.45" Flow Length=430' Tc=21.5 min CN=89 Runoff=1.23 cfs 0.096 af Pond 1: Peak Elev--1,044.80' Inflow=4.83 cfs 0.296 af 24.0" Round Culvert n=0.015 L=35.0' S=-0.0049 T Cutflow=4.83 cfs 0.296 af Pond 1P: East Filtration Swale Peak Elev--1,060.22' Storage=0.101 af Inflow=0.71 cfs 0.158 af Discarded=0.07 cfs 0.146 af Primary --0.00 cfs 0.000 af Outflow=0.07 cfs 0.146 af Pond 2P: West Filtration Swale Peak Elev--1,051.25' Storage=0.038 af Inflow=0.95 cfs 0.093 af Disrarded=0.04 cfs 0.065 af Primary --0.75 cfs 0.028 af Outflow=0.78 cfs 0.093 af Pond 3P: Proposed New Underground Storm Peak Elev=1,040.77' Storage=0.368 af Inflow=5.81 cfs 0.420 af Discarded=0.04 cfs 0.226 af Primary --0.00 cfs 0.000 af Outflow=0.04 cfs 0.226 af Total Runoff Area = 14.391 ac Runoff Volume = 0.643 af Average Runoff Depth = 0.54" 72.15% Pervious = 10.383 ac 27.85% Impervious = 4.008 ac MMW North Park Lot Add 9-1-15 Type // 24 -hr I year Rainfall=2.49" Prepared by Microsoft Printed 9/8/2015 HydroCAD@)10.00-12 s/nO6027 @2014 HydroCAD Software Solubons LLC Facie 7 Summary for Subcatchnient All: East Grass Fields & Tennis Cts Runoff 0.71 cfs @ 12.56 hrs, Volume= 0.158af, Depth= 0.29" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hirs Type 11 24 -hr 1 year Rainfall=2.49" Area (ac) CN Descrii)tion 5.778 61 >75% Grass cover, Good, HSG B 0.689 98 Paved parking, HSG A 6.467 65 Weighted Average 5.778 89.35% Pervious Area 0.689 10.65% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (fttft) (ft/sec) (cfs) 43.6 300 0.0150 0.11 Sheet Flow, Existing grass play field CN=65 Grass: Dense n= 0.240 P2= 2.50" 1.4 100 0.0200 1.22 Sheet Flow, Paved Path Smoothsurfaces n=0.011 P2=2.50" 45.0 400 Total 0.75 0.7 0.65 0.6 0.55 0.5 9 0.45 0.4 Z 0.35 0.3 0.25 0.2 0.15 0.1 0.05 Subcatchnient All: East Grass Fields & Tennis Cts Hydrograph 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Tim (houm) 0.7 Type 11 24 -hr 1 year Rainfall=2.49" Runoff Area=6.467 ac Runoff Volume=0.158 af Runoff Depth=0.29" Flow Length=400' Tc=45.0 min CN=65 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Tim (houm) MMW North Park Lot Add 9-1-15 Type // 24 -hr 1 year Rainfall=Z 49" Prepared by Microsoft Printed 9/8/2016 HydroCAD@10.00-12 stn06O27 @2014 HydroCAD Software Solutions LLC Facie 8 Surnimary for Subeatchnient A2: West Grass & Tennis Courts Runoff 0.95 cfs @ 12.25 hrs, Volume= 0.093 af, Depth= 1.37" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hirs, dt= 0.01 hrs Type 11 24 -hr 1 year Rainfall=2.49" Area (ac) CN DescriDtion 0.600 98 Path 0.209 61 >75% Grass cover, Good, HSG B 0.809 a8 Weighted Average 0.209 25.83% Pervious Area 0.600 74.17% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft1ft) (ft/sec) (Gfs) 3.7 300 0.0150 1.35 Sheet Flow, Minnetonka HS Smooth surfaces n= 0.011 P2= 2.50" 26.9 300 0.0500 0.19 Sheet Flow, West Grass Grass: Dense n= 0.240 P2= 2.50" 30.6 600 Total Subcatchiment A2: West Grass & Tennis Courts Hydrograph Type 11 24 -hr I year Rainfall=2.49" Runoff Area=0.809 ac Runoff Volume=0.093 af Runoff Depth=1.37" Flow Lenath=600' I 1 0 Tc=30.6 min I I E CN=88 0 i i I 0 2 4 6 8 10 12 14 1 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 60 62 54 56 58 60 Tim (houm) MMW North Park Lot Add 9-1-15 Type // 24 -hr I year Rainfall=2.49" Prepared by Microsoft Printed 9/8/2015 HydroCAD010.00-12 s/nO6O27 9)2014HvdroCADSofKvareSolutonsLLC Pqnp q Summary for Subcatchment Al Main Parking Lot Runoff 4.83 cfs @ 12.04 hrs, Volume= 0.296 af, Depth= 0.56" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr 1 year Rainfall=2.49" Area fac) CN DescriDtion 2.110 98 Parking Lot 4.211 61 >75% Grass cover, Good, HSG B 6.321 73 Weighted Average 4.211 66.62% Pervious Area 2.110 33.38% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (fttft) (ft/sec) (cfs) 4.4 300 0.0100 1.15 Sheet Flow, Minnetonka HS Smoothsurfaces n=0.011 P2=2.50" 6.4 50 0.0200 0.13 Sheet Flow, Grass: Short n=0.150 P2=2.50" 10.8 350 Total Subcatchment Al Main Parkiing Lot Hydrograph 1 4.83 ds I Type 11 24 -hr 1 year Rainfall=2.49" Runoff Area=6.321 ac Runoff Volume=0.296 af Runoff Depth=0.56" Flow Length=350' Tc=10.8 min CN=73 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 Tim (houm) MMW North Park Lot Add 9-1-15 Type // 24 -hr I year Rainfall=2.49" Prepared by Microsoft Printed 9/8/2015 HydroCADO 10.00-12 s1n 06027 @ 2014 HydroCAD Software Solutions LLC Paae 10 Summary for Subcatchnient A4: Proposed Padding Lot & widened Drive Runoff 1.23 cis @ 12.14 hrs, Volume= 0.096 af, Depth= 1.45" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr I year Rainfall=2.49" Area (ac) CN DescriDtion 0.609 98 Parking Lot 0.185 61 >75% Grass cover, Good, HSG B 0.794 89 Weighted Average 0.185 23.30% Pervious Area 0.609 76.70% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (fttft) (ft/sec) (ds) 3.8 250 0.0100 1.11 Sheet Flow, Minnetonka HS Smoothsurfaces n=0.011 P2=2.50" 17.7 180 0.0200 0.17 Sheet Flow, Grass: Short n= 0.150 P2= 2.50" 21.5 430 Total Subcatchnient A4: Proposed Parking Lot & Widened Drive Hydrograph Type 11 24 -hr 1 year Rainfall=2.49" 11 1 E Runoff Area=0.794 ac Runoff Volume=0.096 af Runoff Depth=1.45" Flow Length=430' Tc=21.5 min CN=89 4 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 Tim (h�) MMW North Park Lot Add 9-1-15 Type// 24 -hr I year Raintall=2.49 " Prepared by Microsoft Printed 9/8/2015 HydroCAD010.00-12 s/nO6O27 @2014 HydroCAD Software Solutions LLC PaQe 11 Summary for Pond 1: [571 Hint: Peaked at 1,044.80'(Flood elevation advised) Inflow Area 6.321 ac, 33.38% Impervious, Inflow Depth = 0.56" for I year event Inflow 4.83 cfs @ 12.04 hrs, Volume= 0.296 af Outflow 4.83 cfs @ 12.04 hrs, Volume= 0.296 af, Atten= 0%, Lag= 0.0 min Primary 4.83 cfs @ 12.04 hrs, Volume= 0.296 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,044.80'@ 12.04 hrs Device Routing Invert Outlet Devices #1 Primary 1,043.67' 24.0" Round Culvert L= 35.0' RCP, sq.cut end projecting, Ke= 0.500 Inlet/ Outlet Invert= 1,043.50'/ 1,043.67' S= -0.0049P Cc=0.900 n= 0.015 Concrete sewer w/manholes & inlets, Flow Area= 3.14 sf Primary OutFlow Max=4.82 cfs @ 12.04 hrs HW=1,044.80' TW=1,039.34' (Dynamic Tailwater) 't--I=Culvert (Barrel Controls 4.82 cfs @ 3.17 fps) 5 2 0 0 2 4 6 i 10 12 1'4 16 18 iO Pond 1: Hydrograph Inflow Area=6.321 ac Peak Elev=1,044.80' 24.011 Round Culvert n=0.01 5 L=35.0' S=-0.00497' 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Tim (houm) Fe T[fi---i I I Pnmary I MMW North Park Lot Add 9-1-15 Type // 24 -hr I year Rainfall=2.49" Prepared by Microsoft Printed 9/8/2015 HvdroCAD@10.00-12 s1n06027 @2014 HvdroCAD Software Solutions LLC Paae 12 Summary for Pond I P: East Filtration Swale Inflow Area = 6.467 ac, 10.65% Impervious, Inflow Depth = 0.29" for 1 year event Inflow 0.71 efs @ 12.56 hrs, Volume= 0.158 af Outflow 0.07 efs @ 23.19 hrs, Volume= O.W af, Affen= 90%, Lag= 637.5 min Discarded 0.07 cfs @ 23.19 hrs, Volume= 0. 146 af Primary 0.00 cfs @ 0.00 hrs, Volume= 0.000 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,060.22'@ 23.19 hrs Surf.Area= 0.178 ac Storage= 0.101 af Plug -Flow detention time= 1,030.9 min calculated for 0.146 af (92% of inflow) Center -of -Mass det. time= 992.7 min ( 1,953.8 - 961.1 ) Volume Invert Avail.Storage Storage Description #1 1,059.00- 0.343af Custom Stage Data (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (acres) (acre-feet) (acre-feet) 1,059.00 0.040 0.000 0.000 1,060.00 0.100 0.070 0.070 1,061.00 0.447 0.273 0.343 Device Routing Invert Outlet Devices #1 Primary 1,055.00' 18.0" Round Culvert L= 140.0' RCP, mitered to conform to fill, Ke= 0.700 Inlet/ Outlet Invert= 1,055.00'/ 1,046.00' S=0.0643'P Cc=0.900 n=0.010 PVC, smooth interior, FlowArea=1.77sf #2 Device 1 1,060.40' 24.0"Horiz.Orifice/Grate C=0.600 Limited to weir flow at low heads #3 Discarded 1,059.00' 0.500 in/hr ExIliltration over Surface area from 1,059.W - 1,060.5V Excluded Surface area = 0.040 ac Phase -In= 0.01' Discarded OutFlow Max=0.07 cfs @ 23.19 hrs HW=1,060.22' (Free Discharge) 't--3--Exfiltration (Exfiltration Controls 0.07 cfs) Primary OutFlow Max=0.00 cfs @ 0.00 hrs HW=1,059.00' TW=1,039.00' (Dynamic Tailwater) '�—`!=Culvert (Passes 0.00 cfs of 13.53 afs potential flow) '�-2=Orifice/Grate (Controls 0.00 Gfs) MMW North Park Lot Add 9-1 -15 Type // 24 -hr I year Rainfafi=2.49" Prepared by Microsoft Printed 9/8/2015 HydroCAD@10.00-12 s/nO6027 (92014 HydroCAD Software Solubons LLC Page 13 raw Pond I P: East Filtration Swale Hydrograph 0 2 4 6 8 1012141618202224262830323436384042444648505254565860626466687072 Tim (houm) 0 lnl� Ej outfl� '467 ac Inflow Area=Ep. 0 Dj�rded E Pnmary Peak Elev=1,060.22' Storage=0.101 af 0 2 4 6 8 1012141618202224262830323436384042444648505254565860626466687072 Tim (houm) MMW North Park Lot Add 9-1 -15 Type // 24 -hr I year Rainfali=2.49" Prepared by Microsoft Printed 9/8/2015 HydroCAD010.00-12 s1n06027 @2014 HydroCAD Software Solutions LLC Page 14 Summary for Pond 2P: West Filtration Swale [93] Warning: Storage range exceeded by 0.25' [87] Warning: Oscillations may require smaller dt or Finer Routing (severity --48) Inflow Area 0.809 ac, 74.17% Impervious, Inflow Depth = 1.37" for 1 year event Inflow 0.95 cfs @ 12.25 hrs, Volume= 0.093 af Outflow 0.78 cfs @ 12.52 hrs, Volume= 0.093 af, Atten= 17%, Lag= 16.3 min Discarded 0.04 cfs @ 12.52 hrs, Volume= 0.065 af Primary 0.75 efs @ 12.52 hrs, Volume= 0.028 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,051.25'@ 12.52 hrs Surf.Area= 0.082 ac Storage= 0.038 af Plug -Flow detention time= 399.3 min calculated for 0.093 af (100% of inflow) Center -of -Mass det. time= 399.4 min ( 1,244.9 - 845.5 ) Volume Invert Avail.Storage Storage Description #1 1,050.00' 0.038 af Custom Stage Data (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (acres) (acre-feet) (acre-feet) 1,050.00 0.018 0.000 0.000 1,050.50 0.027 0.011 0.011 1,051.00 0.082 0.027 0.038 Device Routing Invert Outlet Devices #1 Primary 1,046.50' 12.0" Round Culvert L= 30.0' RCP, mitered to conform to fill, Ke= 0.700 Inlet/ Outlet Invert= 1,046.50'/ 1,046.00' S=0.0167'P Cc=0.900 n=0.010 PVC, smooth interior, FlowArea=0.79sf #2 Device 1 1,050.90' 24.0" Vert Orifice/Grate C= 0.600 #3 Discarded 1,050.00' 0.500 in/hr Exfiltration over Horizontal area from 1,049.00'- 1,050.90' Conductivity to Groundwater Elevation = 0.00' Excluded Horizontal area = 0.000 ac Phase -In= 0.01' Discarded OutFlow Max=0.04 cfs @ 12.52 hrs HW=1,051.25' (Free Discharge) t--3--Exriltration ( Controls 0.04 ds) Primary OutFlow Max=0.75 cfs @ 12.52 hrs HW=1,051.25' TW=1,039.95' (Dynamic Tailwater) t--I--Culvert (Passes 0.75 cfs of 6.88 cfs potential flow) t--2=Oriflce/Grate (Orifice Controls 0.75 efs @ 2.02 fps) MMW North Park Lot Add 9-1-15 Prepared by Microsoft Type // 24 -hr I year Rainfall=2.49" Printed 9/8/2015 Pond 2P: West Filtration Swale Hydrograph 0 inflm FO 95 cf—sl 0 ouffim E Disairded Inflow Area=01.809 ac 0 Pdmary 0.78 ds Peak Elev=1,051.25' — Storage=0.038 af A 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Tim (houm) MMW North Park Lot Add 9-1-15 Type /I 24 -hr I year Rainla&2.49" Prepared by Microsoft Printed 9/8/2015 HydroCAD010.00-12 s1n06027 (92014 HydroCAD Software Solutions LLC Page 16 Summary for Pond 3P: Proposed New Underground Storm Chambers Inflow Area 14.391 ac, 27.85% Impervious, Inflow Depth = 0.35" for 1 year event Inflow 5.81 cis @ 12.05 hrs, Volurne= 0.420 af Outflow 0.04 Gfs @ 24.19 hrs, Volume= 0.226 af, Atten= 99%, Lag= 728.6 min Discarded 0.04 cfs @ 24.19 hrs, Volurne= 0.226 af Primary 0.00 cfs @ 0.00 hrs, Volurne= 0.000 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,040.77'@ 24.19hrs Surf.Area=0.436ac Storage=0.368af Plug -Flow detention time= (not calculated: outflow precedes inflow) Center -of -Mass det. time= 1,590.8 min ( 2,460.5 - 869.7 ) Volume Invert Avail.Storage Storage Description #11A 1,039.00' 0.726 af 144.08W x 131.89'L x 7.00'H Field A 3.054 af Overall - 1.239 af Embedded = 1.815 af x 40.0% Voids #2A 1,040.50' 1.239 af ADS ' StormTech MC -4500 +Cap x 496 Inside #1 Effeitive Size= 90.4"W x 60.0"H => 26.46 sf x 4.03'L = 106.5 cf Overall Size= 1 00.0"W x 60.0"H x 4.331 with 0.31'Overlap 16 Rows of 31 Chambers Cap Storage= +35.7 cf x 2 x 16 rows = 1, 142.4 cf 1.965 af Total Available Storage Storage Group A created with Chamber Wizard Device Routing Invert Outlet Devices #1 Primary 1,043.00' 18.0" Round Culvert L= 140.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet/ Outlet Invert= 1,043.00'/ 1,040.00' S=0.0214'P Cc=0.900 n= 0.015 Concrete sewer w/manholes & inlets, Flow Area= 1.77 sf #2 Discarded 1,039.00' 0.100 in/hr Exfiltration over Surface area Conductivity to Groundwater Elevation = 0.00' Discarded OutFlow Max=0.04 cfs @ 24.19 hrs HW=1,040.7T (Free Discharge) t--2--Exrlltration ( Controls 0.04 cfs) Primary OutFlow Max=0.00 Gfs @ 0.00 hrs HW=1,039.00' (Free Discharge) t--I=Culvert ( Controls 0.00 Gfs) MMW North Park Lot Add 9-1-15 Type // 24 -hr I year Rainfall=2.49" Prepared by Microsoft Printed 9/8/2015 HydroCACKD 10.00-12 s/n 06027 @ 2014 HydroCAD Software Solutions LLC Page 17 Pond 3P: Proposed New Underground Storm Chambers - Chamber Wizard Field A Chamber Model = ADS — StormTech MC -45W +Cap (ADS StormTech@ MC -45M with end caps) Effective Size= 90.4"W x 60.0"H => 26.46 sf x 4.03'L = 106.5 cf Overall Size= 100.0"W x 60.0"H x 4.33'L with 0.31'Overlap Cap Storage= +35.7 cf x 2 x 16 rows = 1, 142.4 d 100.0" Wide + 7.0" Spacing = 107.0" C -C Raw Spacing 31 Chambers/Row x 4.02'Long +2.56'Cap Length x 2 = 129.89'Row Length +12.0" End Stone x 2 131.89' Base Length 16 Rows x 100.0" Wide + 7.0" Spacing x 15 + 12.0" Side Stone x 2 = 144.08'Base Width 18.0" Base + 60.0" Chamber Height + 6.0"Cover = 7.00'Field Height 496 Chambers x 106.5 ef + 35.7 cf Cap Volume x 2 x 16 Rows = 53,961.7 af Chamber Storage 133,023.7 d Field - 53,961.7 d Chambers = 79,062.1 cf Stone x 40.0% Voids = 31,624.8 Gf Stone Storage Chamber Storage + Stone Storage = 85,586.5 d = 1.965 af Overall Storage Efficiency = 64.3% 496 Chambers 4,926.8 Gy Field 2,928.2 cy Stone MMW North Park Lot Add 9-1-15 Type // 24 -hr I year Rainfall=2.49" Prepared by Microsoft Printed 9/8/2015 HydroCAD@10.00-12 s/n06O27 @2014 HydroCAD Software Solutions LLC Page 18 Pond 3P: Proposed New Underground Storm Chambers Hydrograph 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Tim (houm) !I lonlow .tfl� Inflow Area=14.391 ac Dis�rded in P�mary Peak Elev=1,040.77' Storage=0.368 af 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Tim (houm) MMW North Park Lot Add 9-1 -16 Prepared by Microsoft HydroCAD9 10.00-12 s1n 06027 0 2014 F Type // 24 -hr 10 year Rainfall=4.23" Printed 9/8/2015 Time span=0.00-72.00 hrs, dt=0.01 hrs, 7201 points Runoff by SCS TR -20 method, UH=SCS, Weighted -CN Reach routing by Dyn-Stor-Ind method - Pond routing by Dyn-Stor-Ind method SubcatchmentAll: East Grass Fields &Tennis Runoff Area=6.467ac 10.65% Impervious Runoff Depth=1.16" FlowLength=400' Tc=45.Omin CN=65 Runoff=4.34cfsO.628af SubcatchmentA2: West Grass &Tennis Courts Runoff Area=0.809 ac 74.17% Impervious Runoff Depth=2.94" FlowLength=600' Tc=30.6min CN=88 Runoff=2.03GfsO.198af Subcatchment A3: Main Parking Lot Runoff Area=6.321 ac 33.38% Impervious Runoff Depth=1.69" FlowLength=350' Tc--10.8min CN=73 Runoff=15.96cfsO.893af Subcatchment A4: Proposed Parking Lot & Runoff Area=0.794 ac 76.70% Impervious Runoff Depth=3.04" Flow Length=430' Tc=21.5 min CN=89 Runoff=2.54 ds 0.201 af Pond 1: Peak Elev--1,046.33' lnflow=l 5.96 cfs 0.893 af 24.0" Round Culvert n=0.015 L=35.0' S= -0.0049f Outflow--15.96Gfs 0.893af Pond I P: East Filtration Swale Peak Elev--1,060.62' Storage --0.198 af Inflow --4.34 cfs 0.628 af Discarded --0.12 cfs 0.238 af Primary --2.07 cfs 0.373 af Outflow --2.19 cls 0.611 af Pond 2P: West Filtration Swale Peak Elev--1,051.53' Storage=0.038 af Inflow --2.03 cfs 0.198 af Disr-arded=0.04 cfs 0.075 af Primary --2.30 cfs 0.124 af Outflow=2.34 cfs 0.198 af Pond 3P: Proposed New Underground Storm Peak Elev--1,043.33' Storage=1.295 af Inflow=1 7.97 cls 1.590 af Discarded=O.G4 cfs 0.234 af Primary --0.49 cfs 0.305 af Oufflow=0.53 cfs 0.539 af Total Runoff Area = 14.391 ac Runoff Volume = 1.920 af Average Runoff Depth = 1.60" 72.15% Pervious = 10.383 ac 27.85% Impervious = 4.008 ac MMW North Park Lot Add 9-1 -15 Type // 24 -hr 10 year Rainfall=4.23" Prepared by Microsoft Printed 9/8/2015 HydroCAD@)10.00-12 s/nO6O27 @2014 HydroCAD Software Solubons LLC Paae 20 Summary for Subcatchment Al: East Grass Fields & Tennis Cts Runoff 4.34 efs @ 12.46 hrs, Volume= 0.628af, Depth= 1.16" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr 10 year Rainfall=4.23" Area (ac) CN Descriotion 5.778 61 >75% Grass cover, Good, HSG B 0.689 98 Paved parking, HSG A 6.467 65 Weighted Average 5.778 89.35% Pervious Area 0.689 10.65% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (Gfs) 43.6 300 0.0150 0.11 Sheet Flow, Existing grass play field Grass: Dense n= 0.240 P2= 2.50" 1.4 100 0.0200 1.22 Sheet Flow, Paved Path Smoothsurfaces n=0.011 P2=2.50" 45.0 400 Total Subcatchment Al: East Grass Fields & Tennis Cts Hydrograph Type 11 24 -hr 4 10 year Rainfall=4.23" Runoff Area=6.467 ac 3- Runoff Volume=0.628 af Runoff Depth=1.16" 2 Flow Length=400' Tc=45.0 min I CN=65 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 Tim (houm) MM1W North Park Lot Add 9-1-15 Type // 24 -hr 10 year Rainfall=4.23" Prepared by Microsoft Printed 9/8/2015 HydroCAD@10.00-12 s/n06O27 02014 HydroCAD Software Solutions LLC Paae 21 Summary for Subcatchment A2: West Grass & Tennis Courts Runoff 2.03 cfs @ 12.24 hrs, Volume= 0.198af, Depth= 2.94" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr 10 year Rainfall=4.23" Area (ac) CN DescriDtion 0.600 98 Path 0.209 61 >75% Grass cover, Good, HSG B 0.809 88 Weighted Average 0.209 25.83% Pervious Area 0.600 74.17% Impervious Area Te Length Slope Velocity Capacity Description (min) (feet) (fVft) (ft/sec) (ds) 3.7 300 0.0150 1.35 Sheet Flow, Minnetonka HS SmoothsurfaGes n=0.011 P2=2.50" 26.9 300 0.0500 0.19 Sheet Flow, West Grass Grass: Dense n= 0.240 P2= 2.50" 30.6 600 Total Subcatchment A2: West Grass & Tennis Courts Hydrograph Type 11 24 -hr 10 year Rainfall=4.23" Runoff Area=0.809 ac Runoff Volume=0.198 af Runoff Depth=2.94" Flow Length=600' Tc=30.6 min 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 rim (houm) CN=88 MMW North Park Lot Add 9-1 -15 Type // 24 -hr 10 year Rainfafi=4.23" Prepared by Microsoft P6nted 9/8/2015 HydroCAD@10.00-12 s/n06O27 @2014 HydroCAD Software Solutions LLC Page 22 Summary for Subcatchment Al Main Parlding Lot Runoff 15.96 ds @ 12.03 hrs, Volume= 0.893 af, Depth= 1.69" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr 10 year Rainfall=4.23" Area (ac) CN DescriDtion 2.110 98 Parking Lot 4.211 61 >75% Grass cover, Good, HSG B 6.321 73 Weighted Average 4.211 66.62% Pervious Area 2.110 33.38% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 4.4 300 0.0100 1.15 Sheet Flow, Minnetonka HS Smoothsurfaces n=0.011 P2=2.50" 6.4 50 0.0200 0.13 Sheet Flow, Grass:Short n=0.150 P2=2.50" 10.8 350 Total Subeatchment Al Main Parking Lot Hydrograph 171 1 1 16.96 cfs 16 Type 11 24 -hr 15- 14- 10 year Rainfall=4.23" 13� 12 Runoff Area=6.321 ac 11� Runoff Volume=0.893 af 10� Runoff Depth=1.69" iL- 8 Flow Length=350' 7 I Tc=10.8 min CN=73 0 2 4 6 8 10 12 14 16 IS 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Tim (houm) MMW North Park Lot Add 9-1-15 Type // 24 -hr 10 year Rainfall=4.23" Prepared by Microsoft Printed 9/8/2015 HydroCAD@)10.00-12 stnO6O27 @2014 HydroCAD Soffivare Solutions LLC Paae 23 Summary for Subcatchment A4: Proposed Parking Lot & Widened Drive Runoff 2.54 cfs @ 12.14 hrs, Volume= 0.201 af, Depth= 3.04" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr 10 year Rainfall=4.23" Area (ac) CN DescriDtion 0.609 98 Parking Lot 0.185 61 >75% Grass cover, Good, HSG B 0.794 89 Weighted Average 0.185 23.30% Pervious Area 0.609 76.70% Impervious Area Tc Length Slope On) (feet) (ftfft) 3.8 250 0.0100 Velocity Capacity Description 17.7 180 0.0200 0.17 21.5 430 Total Sheet Flow, Minnetonka HS Smoothsurfaces n=0.011 P2=2.50" Sheet Flow, Grass:Short n=0.150 P2=2.50" Subcatchment A4: Proposed Parking Lot& Widened Drive Hydrograph Type 11 24 -hr 10 year Rainfall=4.23" 21 1 E Runoff Area=0.794 ac Runoff Volume=0.201 af Runoff Depth=3.04" Flow Lanoth=430' 11 1 E Tc=21.5 min CN=89 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Tim (houm) MMW North Park Lot Add 9-1 -15 Type // 24 -hr 10 year Rainfali=4.23" Prepared by Microsoft Printed 9/8/2015 HydroCAD& 10.00-12 s/n 06027 0 2014 HydroCAD Software Solutions LLC Paae 24 Summary for Pond 1: [57] Hint: Peaked at 1,046.33'(Flood elevation advised) Inflow Area 6.321 ac, 33.38% Impervious, Inflow Depth = 1.69" for 10 year event Inflow 15.96 cfs @ 12.03 hrs, Volume= 0.893 af Outflow 15.96 cfs @ 12.03 hrs, Volume= 0.893 af, Atten= 0%, Lag= 0.0 min Primary 15.96 cfs @ 12.03 hrs, Volume= 0.893 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,046.33'@ 12.03 hrs Device Routing Invert Outlet Devices #1 Primary 1,043.67' 24.0" Round Culvert L= 35.0' RCP, sq.cut end projecting, Ke= 0.500 Inlet/ Outlet Invert= 1,043.50'/ 1,043.67' S= -0.0049T Cc=0.900 n= 0.015 Concrete sewer w/manholes & inlets, Flow Area= 3.14 sf Primary OutFlow Max=1 5.95 Gfs @ 12.03 hrs HW=1,046.33' TW=1,040.50' (Dynamic Tailwater) '�—I!=Culverlt (Barrel Controls 15.95 cfs @ 5.08 fps) Pond 1: Hydrograph Fit 10 Pnmary I .1 1 b.. 16 Inflow Area=6.321 ac 15- 14 Peak Elev=1,046.33' 13 24.091 12� 11 Round Culvert 9 n=0.01 5 7 L=35.0' 6 5 S=-0.00497' 4 3 1 1 0 2 4 6 8 10 12 14 16 18 20 22 24 i6 i8 iO i2 3 . 43 . 63 . 8 40 42 44 46 48 50 52 54 56 58 6 1 06 1 2 64 66 68 70 72 Tim (houm) MMW North Park Lot Add 9-1 -15 Type // 24 -hr 10 year Rainfall=4.23" Prepared by Microsoft Printed 9/8/2015 HydroCAD@10.00-12 s/n06O27 @2014 HydroCAD Software Solutions LLC Page 25 Summary for Pond 1P: East Filtration Swale Inflow Area 6.467 ac, 10.65% Impervious, Inflow Depth = 1.16" for 10 year event Inflow 4.34 cfs @ 12.46 hrs, Volume= 0.628 af Oufflow 2.19 cfs @ 12.98 hrs, Volume= 0.611 af, Atten= 50%, Lag= 31.7 min Discarded 0.12Gfs@ 12.64hrs, Volume= 0.238 af Primary 2.07 ds @ 12.98 hrs, Volume= 0.373 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,060.62'@ 12.98 hrs Surf.Area=0.314ac Storage=0.198af Plug -Flow detention time= 368.4 min calculated for 0.611 af (97% of inflow) Center -of -Mass det. time= 353.9 min ( 1,258.9 - 905.0 ) Volume I nvert Avail.Storage Storage Description #1 1,059.00, 0.343 af Custom Stage Data (Prismatic) Listed below (ReGalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (acres) (acre-feet) (acre-feet) 1,059.00 0.040 0.000 0.000 1,060.00 0.100 0.070 0.070 1,061.00 0.447 0.273 0.343 Device Routing Invert Outlet Devices #1 Primary 1,055.00' 18.0" Round Culvert L= 140.0' RCP, mitered to conform to fill, Ke= 0.700 Inlet/ Outlet Invert= 1,055.00'/ 1,046.00' S=0.0643'P Cc=0.900 n= 0.010 PVC, smooth interior, Flow Area= 1.77 sf #2 Device 1 1,060.40' 24.0"Horiz.Orifice/Grate C=0.600 Limited to weir flow at low heads #3 Discarded 1,059.00' 0.500 in/hr Exfiltration over Surface area from 1,059.00' - 1,060.50' Excluded Surface area = 0.040 ac Phase -In= 0.01' Discarded OutFlow Max=0.12 efs @ 12.64 hrs HW=1,060.50' (Free Discharge) t--3--Exriltration (Exhitration Controls O.12cfs) Primary OutFlow Max=2.07 ds @ 12.98 hrs HW=1,060.62' TW=1,041.84' (Dynamic Tailwater) t--1 --Culvert (Passes 2.07 ds of 16.56 cfs potential flow) t-2=Orifice/Grate (Weir Controls 2.07 cfs @ 1.52 fps) MMW North Park Lot Add 9-1 -15 Type I/ 24 -hr 10 year Rainfall=4.23" Prepared by Microsoft Printed 9/8/2015 HvdroCAD@10.00-12 s(nO6O27 @2014 HvdroCAD Software Solubons LLC Pacie 26 Pond I P: East Filtration Swale Hydrograph Tim (houm) IN Infim O=ed MMW North Park Lot Add 9-1-15 Prepared by Microsoft Type /I 24 -hr 10 year Rainfall=4.23" Printed 9/812015 Summary for Pond 2P: West Filtration Swale [93] Warning: Storage range exceeded by 0.53' [90] Warning: Qout>Qin may require smaller dt or Finer Routing [87) Warning: Oscillations may require smaller dt or Finer Routing (severity --142) Inflow Area = 0.809 ac, 74.17% Impervious, Inflow Depth = 2.94" for 10 year event Inflow 2.03 cfs @ 12.24 hrs, Volume= 0.198 at outflow 2.34 cfs @ 12.24 hrs, Volume= 0.198 af, Atten= 0%, Lag= 0.0 min Discarded 0.04 Gfs @ 12.24 hrs, Volume= 0.075 at Primary 2.30 cfs @ 12.24 hrs, Volume= 0.124 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,051.5T @ 12.24 hrs Surf.Area= 0.082 ac Storage= 0.038 af Plug -Flow detention time= 224.7 min calculated for 0.198 at (100% of inflow) Center -of -Mass det. time= 224.7 min ( 1,048.4 - 823.8 ) Volume Invert Avail.Storaqe Storage Description #1 1,050.00' 0.038 af Custom Stage Data (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (acres) (acre-feet) (acre-feet) 1,050.00 0.018 0.000 0.000 1,050.50 0.027 0.011 0.011 1,051.00 0.082 0.027 0.038 Device Routing Invert Outlet Devices #1 Primary 1,046.50' 12.0" Round Culvert L= 30.0' RCP, mitered to conform to fill, Ke= 0.700 Inlet/ Outlet Invert= 1,046.50'/ 1,046.00' S=0.0167'P Cc=0.900 n=0.010 PVC, smooth interior, FlowArea=0.79sf #2 Device 1 1,050.90' 24.0" Vert. Orifice/Grate C= 0.600 #3 Discarded 1,050.00' 0.500 in/hr Exfiltration over Horizontal area from 1,049.00'- 1,050.90' Conductivity to Groundwater Elevation = 0.00' Excluded Horizontal area = 0.000 ac Phase -In= 0.01' Discarded OutFlow Max=0.04 cfs @ 12.24 hrs HW=1,051.53' (Free Discharge) 't-3--Exfiltration ( Controls 0.04 cfs) Primary OutFlow Max=2.30 cfs @ 12.24 hrs HW=1,051.53' TW=1,041.10' (Dynamic Tailwater) '�—A=Culvert (Passes 2.30 cfs of 7.10 cfs potential flow) '�-2--OriflcelGrate (Orifice Controls 2.30 cfs @ 2.71 fps) MMW North Park Lot Add 9-1-15 Type // 24 -hr 10 year Rainfall=4. 23" Prepared by Microsoft Printed 9/8/2015 HydroCAD810.00-12 sInO6027 @2014 HydroCAD Software Solutions LLC Page 28 Pond 2P: West Filtration Swale Hydrograph Tim (houm) E i "tn ,dId MMW North Park Lot Add 9-1-15 Prepared by Microsoft HydroCAD@) 10.00-12 s(n 06027 @ 2014 1 - Type // 24 -hr 10 year Rainfall=4.23" Printed 9/8/2015 Summary for Pond 3P: Proposed New Underground Storm Chambers Inflow Area = 14.391 ac, 27.85% Impervious, Inflow Depth = 1.33" for 10 year event Inflow 17.97 ds @ 12.04 hrs, Volume= 1.590 af Outflow 0.53 cfs @ 19.32 hrs, Volume= 0.539 af, Atten= 97%, Lag= 437.2 min Discarded 0.04 cfs @ 19.32 hrs, Volume= 0.234 af Primary 0.49cfs@ 19.32hrs, Volume= 0.305 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,043.33'@ 19.32 hrs Surf.Area=0.436ac Storage=1.295af Plug -Flow detention time= (not calculated: outflow precedes inflow) Center -of -Mass det. time= 906.2 min ( 1,766.9 - 860.6 ) Volume Invert Avail.Storaae Storaae Descriotion #1A 1,039.00' 0.726 af 144.08W x 131.89'L x 7.00'H Field A 3.054 af Overall - 1.239 af Embedded = 1.815 af x 40.0% Voids #2A 1,040.50' 1.239 af ADS StonnTech MC -4500 +Cap x 496 Inside #1 Effe(Ttive Size= 90.4"W x 60.0"H => 26.46 sf x 4.031 = 106.5 cf Overall Size= 1 00.0"W x 60.0"H x 4.33'L with 0.3l'Ovedap 16 Rows of 31 Chambers CaD Storaae= +35.7 cf x 2 x 16 rows = 1.142.4 d 1.965 af Total Available Storage Storage Group A created with Chamber Wizard Device Routing Invert Outlet Devices #1 Primary 1,043.00' 18.0" Round Culvert L= 140.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet/ Outlet Invert= 1,043.00'/ 1,040.00' S=0.0214'P Cc=0.900 n= 0.015 Concrete sewer w/manholes & inlets, Flow Area= 1.77 sf #2 Discarded 1,039.00' OADO in/hr Exfiltration over Surface area Conductivity to Groundwater Elevation = 0.00' Discarded OutFlow Max=0.04 cfs @ 19.32 hrs HW=1,043.33' (Free Discharge) 't-2--Exifiltration ( Controls 0.04 cfs) Primary OutFlow Max=0.49 ds @ 19.32 hrs HW=1,043.33' (Free Discharge) 't--I=Culvert (Inlet Controls 0.49 ds @ 1.72 fps) MMW North Park Lot Add 9-1-15 Type I/ 24 -hr 10 year Rainfall=4.23" Prepared by Microsoft Printed 9/8/2015 HydroCAD010.00-12 sIn06027 02014 HydroCAD Software Solutions LLC — — Page 30 Pond 3P: Proposed New Underground Storm Chambers - Chamber Wizard Field A Chamber Model = ADS–StormTech MC -4500 +Cap (ADS StormTechO MC -4500 with end caps) Effective Size= 90.4"W x 60.0"H => 26.46 sf x 4.03'L = 106.5 ef Overall Size= 100.0"W x 60.0"H x 4.33'L with 0.31'Overlap Cap Storage= +35.7 cf x 2 x 16 rows = 1,142.4 cf 100.0" Wide + 7.0" Spacing = 107.0" C -C Row Spacing 31 Chambers/Row x 4.02'Long +2.56'Cap Length x 2 = 129.89'Row Length +12.0" End Stone x 2 131.89' Base Length 16 Rows x 100.0" Wide + 7.0" Spacing x 15 + 12.0" Side Stone x 2 = 144.08'Base Width 18.0" Base + 60.0" Chamber Height + 6.0" Cover = 7.00' Field Height 496 Chambers x 106.5 cf + 35.7 Gf Cap Volume x 2 x 16 Rows = 53,961.7 cf Chamber Storage 133,023.7 Gf Field - 53,961.7 cf Chambers = 79,062.1 cf Stone x 40.0% Voids = 31,624.8 cf Stone Storage Chamber Storage + Stone Storage = 85,586.5 cf = 1.965 af Overall Storage Efficiency = 64.3% 496 Chambers 4,926.8 cy Field 2,928.2 cy Stone MMW North Park Lot Add 9-1-15 Type /I 24 -hr 10 year Rainfafi=4.23" Prepared by Microsoft Printed 9/812015 HydroCAD@10.DG-12 s/nO6O27 @2014 HydroCAD Software SolufionsLLC Page 31 Pond 3P: Proposed New Underground Storm Chambers Hydrograph Im `7 20 Inflow Area=1 4.391 ac M ded 19 18 Peak Elev=1,043.33' 17 16( Storage=1.295 af 10 9 0.53 ds 0.49 ds 8 10 12 14 16 1820 222426 28 3032 3436 38 4042 " 4648 5052 54 5658 606264 66 6870 72 Tim (houm) MMW North Park Lot Add 9-1-15 Type // 24 -hr 100 year Rainfall=7.29" Prepared by Microsoft Printed 9/8/2015 HvdroCAD@10.00-12 s/nO6027 @2014 HvdroCAD Software Solutions LLC Paae 32 Time span=0.00-72.00 hrs, dt=0.01 hrs, 7201 points Runoff by SCS TR -20 method, UH=SCS, Weighted -CN Reach routing by Dyn-Stor-Ind method - Pond routing by Dyn-Stor-Ind method Subcatchment All: East Grass Fields & Tennis Runoff Area=6.467 ac 10.65% Impervious Runoff Depth=3.33" Flow Length=400' Tc=45.0 min CN=65 Runoff=13.93 cfs 1.794 af Subcatchment A2: West Grass & Tennis Courts Runoff Area=0.809 ac 74.17% Impervious Runoff Depth=5.88" Flow Length=600' Tc --30.6 min CN=88 Runoff=3.94 cfs 0.396 af Subcatchment A3: Main Parking Lot Runoff Area=6.321 ac 33.38% Impervious Runoff Depth=4.19" Flow Length=350' Tc=1 0.8 min CN=73 Runoff=39.44 cfs 2.205 af Subcatchrrient A4: Proposed Parking Lot & Runoff Area=0.794 ac 76.70% Impervious Runoff Depth=5.99" Flow Length=430' Tc=21.5 min CN=89 Runoff=4.84 cfs 0.396 af Pond 1: Peak Elev--1,051.47' Inflow --39.44 efs 2.205 af 24.0" Round Culvert n=0.015 L=35.0' S= -0.0049'P Outflow --39.44 cfs 2.205 af Pond IP: East Filtration Swale Peak Elev--1,061.47' Storage=0.343af Inflow--13.93cfs 1.794 af Discarded=0.12 cfs 0.252 af Primary --15.66 cfs 1.525 af Cutflow--15.78 Cfs 1.777 af Pond 2P: West Filtration Swale Peak Elev--1,051.76' Storage=0.038 af lnflow=3.94 cfs 0.396 af Discarded=0.04 cis 0.083 af Primary=4.05 cfs 0.313 af Outflow=4.08 cfs 0.396 af Pond 3P: Proposed New Underground Storm Peak Elev--1,045.89' Storage=1.946 af lnflow=45.59 cfs 4.439 af Disr-arded=0.04 cfs 0.244 af Primary --1 0.99 cfs 3.139 af Outflow=1 1.03 cfs 3.383 af Total Runoff Area = 14.391 ac Runoff Volume = 4.791 af Average Runoff Depth = 4.00" 72.15% Pervious = 10.383 ac: Z7.85% Impervious = 4.008 ac MMW North Park Lot Add 9-1 -15 TypeI124-hr 100 year Rainfafl=7.29" Prepared by Microsoft Printed 9/8/2015 HydroCAE)@10.00-12 s/nO6O27 @2014 HydroCAD Software Solutions LLC Page 33 Summary for Subcatchment All: East Grass Fields & Tennis Cts Runoff 13.93 ds @ 12.45 hrs, Volume= 1.794 af, Depth= 3.33" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr 100 year Rainfall=7.29" Area (ac) CN Descrir)tion 5.778 61 >75% Grass cover, Good, HSG B 0.689 98 Paved parking, HSG A 6.467 65 Weighted Average 5.778 89.35% Pervious Area 0.689 10.65% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 43.6 300 0.0150 0.11 Sheet Flow, Existing grass play field Grass: Dense n= 0.240 P2= 2.50" 1.4 100 0.0200 1.22 Sheet Flow, Paved Path Smooth surfaces n= 0.011 P2= 2.50" 45.0 400 Total Subcatchment All: East Grass Fields & Tennis Cts Hydrograph 1 1193 ds j W Type 11 24 -hr 13 12 100 year Rainfall=7.29" 11� Runoff Area=6.467 ac 10� Runoff Volume=1.794 af 9 8 Runoff Depth=3.33" 0 M 7 Flow Length=400' 6 Tc=45.0 min 5 4 CN=65 0 1 F"W 6 2 4 6 8 lo 12 14 16 18 20 22 24 26 28 iO 32 34 36 38 40 42 44 46 48 �O 52 54 �6 58 60 6 i4 (i(3 68 70 72 Tim jhoum) NIMW North Park Lot Add 9-1 -15 Type // 24 -hr 100 year Rainfall=7.29" Prepared by Microsoft Printed 9/8/2015 HydroCAD010.00-12 s/nO6O27 @2014 HydroCAD Software Solutions LLC Pacte 34 Summary for Subcatchment A2: West Grass & Tennis Courts Runoff 3.94 cfs @ 12.24 hrs, Volume= 0.396 af, Depth= 5.88" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr 100 year Rainfall=7.29" Area (ac) CN DescriDtion 0.600 98 Path 0.209 61 >75% Grass cover, Good, HSG B 0.809 88 Weighted Average 0.209 25.83% Pervious Area 0.600 74.17% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 3.7 300 0.0150 1.35 Sheet Flow, Minnetonka HS SmoothsurfaGes n=0.011 P2=2.50" 26.9 300 0.0500 0.19 Sheet Flow, West Grass Grass: Dense n= 0.240 P2= 2.50" 30.6 600 Total Subcatchment A2: West Grass & Tennis Courts Hydrograph Type 11 24 -hr 100 year Rainfall=7.29" 3- Runoff Area=0.809 ac Runoff Volume=0.396 af Runoff Depth=5.88" 2 - Flow Length=600' Tc=30.6 min I CN=88 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 TIm (houm) MMW North Park Lot Add 9-1-15 Prepared by Microsoft Software Type // 24 -hr 100 year Rainfall=7.29" Printed 9/8/2015 Summary for Subeatchment Al Main Parliking Lot Runoff 39-44 ds @ 12.03 hrs, Volume= 2.205 af, Depth= 4.19" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr 100 year Rainfall=7.29" Area (ac) CN DescriDtion 2.110 98 Parking Lot 4.211 61 >75% Grass cover, Good, HSG B 6.321 73 Weighted Average 4.211 66.62% Pervious Area 2.110 33.38% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (fVft) (ft/sec) (cfs) 4.4 300 0.0100 1.15 Sheet Flow, Minnetonka HS CN=73 10 8 Smooth surfaces n= 0.011 P2= 2.50" 6.4 50 0.0200 0.13 Sheet Flow, Grass:Short n=0.150 P2=2.50" 10.8 350 Total Subcatchnient Al Main Parking Lot Hydrograph 38 Type 11 24 -hr 36 34 100 year Rainfall=7.29" 32 30 Runoff Area=6.321 ac 28 Runoff Volume=2.205 af 26 24 Runoff Depth=4.19" 22 20 Flow Length=350' 18 16 Tc=10.8 min 14 12 CN=73 10 8 61 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 a6 38 40 42 44 46 48 Tim (houm) MMW North Park Lot Add 9-1 -15 Type // 24 -hr 100 year Raintafi=7.29" Prepared by Microsoft Printed 9/8/2015 HydroCAD@10.00-12 s/nO6O27 @2014 HydroCAD Software Solutionsi-l-C — — Pacie 36 Summary for Subcatchrnent A4: Proposed Parking Lot & Widened Drive Runoff 4.84 ds @ 12.13 hrs, Volume= 0.396 af, Depth= 5.99" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr 100 year Rainfall=7.29" Area (ac) CN 0.609 98 Parking Lot 0.185 61 >75% Grass cover, Good, HSG B 0.794 89 Weighted Average 0.185 23.30% Pervious Area 0.609 76.70% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (fttft) (ft/sec) (cfs) 3.8 250 0.0100 1.11 Sheet Flow, Minnetonka HS Smooth surfaces n= 0.011 P2= 2.50" 17.7 180 0.0200 0.17 Sheet Flow, Grass:Short n=0.150 P2=2.50" 21.5 430 Total Subcatchrrient A4: Proposed Parking Lot & Widened Drive Hydrograph Type 11 24 -hr 100 year Rainfall=7.29" 4 Runoff Area=0.794 ac Runoff Volume=0.396 af 3 Runoff Depth=5.99" Flow Length=430' 21 1 Tc=21.5 min CN=89 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Tim (houm) MMW North Park Lot Add 9-1-15 TypeI124-hr 100 year Rainfafi=7.29" Prepared by Microsoft Printed 9/8/2015 HydroCAD@10.00-12 s/nO6O27 02014 HydroCAD Software Solutions LLC Page 37 Summary for Pond 1: [57] Hint: Peaked at 1,051.47'(Flood elevation advised) Inflow Area 6.321 ac, 33.38% Impervious, Inflow Depth = 4.19" for 100 year event Inflow 39.44 Gfs @ 12.03 hrs, Volume= 2.205 af Outflow 39.44 cfs @ 12.03 hrs, Volume= 2.205 af, Atten= 0%, Lag= 0.0 min Primary 39.44 cfs @ 12.03 hrs, Volume= 2.205 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,051.47' @ 12.03 hrs Device Routing Invert Outlet Devices #1 Primary 1,043.67' 24.0" Round Culvert L= 35.0' RCP, sq.cut end projecting, Ke= 0.500 Inlet / Outlet Invert= 1,043.50'/ 1,043.67' S= -0.0049T Cc= 0.900 n= 0.015 Concrete sewer w/manholes & inlets, Flow Area= 3.14 sf Primary OutFlow Max=39.39 cfs @ 12.03 hrs HW=1,051.45' TW=1,042.06' (Dynamic Tailwater) t--1 =Culvert (Inlet Controls 39.39 cfs @ 12.54 fps) 44 42 40 36 34 32 30 28 26 24 22 20 18 16 12 8 6 4 2 0 WA 0 2 4 6 8 10 12 14 16 18 Pond 1: Hydrograph Tim Jhoum) Fun—fi.--J I S Phmary Inflow Area=6.321 ac Peak Elev=1,051.47' 24.0W1 Round Culvert n=0.015 L=35.0' S=-0.0049'/' 48 50 52 54 56 58 60 62 64 66 68 70 72 MMW North Park Lot Add 9-1-15 TypeI124-hr 100 year Rainfall=7.29" Prepared by Microsoft Printed 9/8/2015 HydroCAD@10.00-12 s/n06O27 @2014 HydroCAD Software Solutions LLC Page 38 Summary for Pond IP: East Filtration Swale [93] Warning: Storage range exceeded by OAT [90] Warning: Qout>Qin may require smaller dt or Finer Routing [871 Warning: Oscillations may require smaller dt or Finer Routing (severity=9) Inflow Area 6.467ac, 10.65% Impervious, InflowDepth= 3.33" for 100yearevent Inflow 13.93 afs @ 12.45 hrs, Volume= 1.794 af Outflow 15.78 cfs @ 12.51 hrs, Volume= 1.777 af, Aften= 0%, Lag= 3.7 min Discarded 0.12 cfs @ 12.19 hrs, Volume= 0.252 af Primary 15.66 ds @ 12.51 hrs, Volume= 1.525 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,061.47'@ 12.51 hrs Surf.Area= 0.447 ac Storage= 0.343 af Plug -Flow detention time= 142.1 min calculated for 1.777 af (99% of inflow) Center -of -Mass det. time= 136.4 min ( 1,009.2 - 872.8 ) Volume Invert Avail.Storage Storage Description #1 1,059.00' 0.343 af Custom Stage Data (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (acres) (acre-feet) (acre-feet) 1,059.00 0.040 0.000 0.000 1,060.00 0.100 0.070 0.070 1,061.00 0.447 0.273 0.343 Device Routing I nvert Outlet Devices #1 Primary 1,055.00' 18.0" Round Culvert L= 140.0' RCP, mitered to conform to fill, Ke= 0.700 Inlet/ Outlet Invert= 1,055.00'/ 1,046.00' S=0.0643P Cc=0.900 n= 0.010 PVC, smooth interior, Flow Area= 1.77 sf #2 Device 1 1,060.40' 24.0"Horiz.Orifice/Grate C=0.600 Limited to weir flow at low heads #3 Discarded 1,059.00' 0.500 in/hr Exfiltration over Surface area from 1,059.00'- 1,060.501 Excluded Surface area = 0.040 ac Phase -In= 0.01' Discarded OutFlow Max=0.12 ds @ 12.19 hrs HW=1,060.52' (Free Discharge) t--3--ftfiltration (Exfiltration Controls 0.12 efs) Primary OutFlow Max=1 5.66 ds @ 12.51 hrs HW=1,061.4r TW=1,044.74' (Dynamic Tailwater) t—I=Culvert (Passes 15.66 cfs of 17.96 cfs potenfial flow) t-2=0rifice/Grate (Orifice Controls 15.66 ds @ 4.99 fps) MMW North Park Lot Add 9-1 -15 Type // 24 -hr 100 year Rainfall=7.29" Prepared by Microsoft Printed 9/8/2015 HydroCAD010.00-12 stn06027 02014 HydroCAD Software Solutions LLC Paae 39 e I C Pond 1P: East Filtration Swale Hydrograph cis Inflow Area=6.467 ac uded Peak Elev=1,061.47' f Storage=0.343 af 0 2 4 6 8 10 12 14 16 182022242628 3032343638 4042444648 505254 565860626466687072 Tim (houm) MMW North Park Lot Add 9-1-15 TypeI124-hr 100 year Rainfall=7.29" Prepared by Microsoft Printed 9/812015 HydroCAD@10.00-12 s/n06O27 @2014 HydroCAD Software Solutions LLC Page 40 Surnimiry for Pond 2P: West Filtration Swale [931 Warning: Storage range exceeded by 0.76' [90] Warning: Qout>Qin may require smaller dt or Finer Routing [871 Warning: Oscillations may require smaller dt or Finer Routing (severity --331) Inflow Area 0.809 ac, 74.17% Impervious, Inflow Depth = 5.88" for 100 year event Inflow 3.94 cfs @ 12.24 hrs, Volume= 0.396 af Outflow 4.08 cfs @ 12.24 hrs, Volume= 0.396 af, Atten= 0%, Lag= 0. 1 min Discarded 0.04 cfs @ 12.24 hrs, Volume= 0.083 af Primary 4.05 cfs @ 12.24 hrs, Volume= 0.313 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,05116'@ 12.24 hrs Surf.Area= 0.082 ac Storage= 0.038 af Plug -Flow detention time= 130.9 min calculated for 0.396 af (100% of inflow) Center -of -Mass clet. time= 131.0 min ( 935.6 - 804.5 ) Volume Invert Avail.Storaqe Storage Description #1 1,050.00' 0.038 af Custom Stage Data (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (acres) (acre-feet) (acre-feet) 1,050.00 0.018 0.000 0.000 1,050.50 0.027 0.011 0.011 1,051.00 0.082 0.027 0.038 Device Routing Invert Outlet Devices #1 Primary 1,046.50' 12.0" Round Culvert L= 30.0' RCP, mitered to conform to fill, Ke= 0.700 Inlet/ Outlet Invert= 1,046.50'/ 1,046.00' S=0.0167P Cc=0.900 n= 0.010 PVC, smooth interior, Flow Area= 0.79 sf #2 Device 1 1,050.90' 24.0" Vert. Orifice/Grate C= 0.600 #3 Discarded 1,050.00' 0.500 in/hr Exfiltrabon over Horizontal area from 1,049.W - 1,050.90' Conductivity to Groundwater Elevation = 0.00' Excluded Horizontal area = 0.000 ac Phase -In= 0.01' Discarded OutFlow Max=0.04 cfs @ 12.24 hrs HW=1,051.76' (Free Discharge) '1—'3=ExfiItration ( Controls 0.04 Gfs) Primary OutFlow Max=4.05 cfs @ 12.24 hrs HW=1,051.76' TW=1,043.69' (Dynamic Tailwater) 't-1 =Culvert (Passes 4.05 cfs of 7.28 cfs potential flow) t--2=Orifice/Grate (Orifice Controls 4.05 Gfs @ 3.15 fps) MMW North Park Lot Add 9-1-15 TypeI124-hr 100 year Rainfafi=729" Prepared by Microsoft Printed 9/8/2015 HydroCAD@10.00-12 s/nO6O27 @2014 HydroCAD Software Solutions LLC Page 41 Pond 2P: West Filtration Swale Hydrograph rim (houm) 0 Infim E Dutflm 0 Dis�rded 0 Pnmary I MMW North Park Lot Add 9-1-15 TypeI124-hr 100 year Rainfall=7.29" Prepared by Microsoft Printed 9/812015 HydroCAD010.00-12 s1n06027 @2014 HydroCAD Software SolubonsLLC Paae 42 Summary for Pond 3P: Proposed New Underground Storm Chambers Inflow Area = 14.391 ac, 27.85% Impervious, Inflow Depth= 3.70" for 100 year event Inflow 45.59 afs @ 12.04 hrs, Volume= 4.439 af Outflow 11.03 cfs @ 13.05 hrs, Volume= 3.383 af, Atten= 76%, Lag= 60.9 min Discarded 0.04 cfs @ 13.05 hrs, Volume= 0.244 af Primary 10.99 afs @ 13.05 hrs, Volume= 3.139 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,045.89'@ 13.05 hrs Surf.Area= 0.436 ac Storage= 1.946 af Plug -Flow detention time= (not calculated: outflow precedes inflow) Center -of -Mass det. time= 210.0 min ( 1,052.0 - 842.0 ) Volume Invert Avail.Storaae Storaae Descriotion #11A 1,039.00' 0.726 af 1".08'W x 131.89'L x 7.00'H Field A 3.054 af Overall - 1.239 af Embedded = 1.815 af x 40.0% Voids #2A 1,040.50' 1.239 af ADS - StonnTech MC -45W +Cap x 496 Inside #1 Effe�tive Size= 90.4"W x 60.0"H => 26.46 sf x 4.03'L = 106.5 Gf Overall Size= 1 00.0-W x 60.0"H x 4.331 with 0.31'Overlap 16 Rows of 31 Chambers Cap Storage= +35.7 cf x 2 x 16 rows = 1,142.4 cf 1.965 af Total Available Storage Storage Group A created with Chamber Wizard Device Routing I nvert Outlet Devices #1 Primary 1,043.00' 18.0" Round Culvert L= 140.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet/ Outlet Invert= 1,043.00'/ 1,040.00' S=0.0214'P Cc=0.900 n= 0.015 Concrete sewer w/manholes & inlets, Flow Area= 1.77 sf #2 Discarded 1,039.00' 0.100 in/hr Exfiltration over Surface area Conductivity to Groundwater Elevation = 0.00' Discarded OutFlow Max=0.04 cfs @ 13.05 hrs HW=1,045.89' (Free Discharge) '�-Z-Exfiltration ( Controls 0.04 Gfs) Primary OutFlow Max=10.99 cfs @ 13.05 hrs HW=1,045.89' (Free Discharge) 't-l=Culvert (Inlet Controls 10.99 cfs @ 6.22 fps) MMW North Park Lot Add 9-1-15 Type /I 24 -hr 100 year Rainfall=7-29" Prepared by Microsoft Printed 9/8/2015 HydroCAD010.00-12 s/nG6027 @2014 HydroCAD Software Solutions LLC Page 43 Pond 3P: Proposed New Underground Stonn Chambers - Chamber Wizard Field A Chamber Model = ADS — StormTech MC -45M +Cap (ADS StormTech@ MC -45M with end caps) Effective Size= 90.4"W x 60.0"H => 26.46 sf x 4.03'L = 106.5 cf Overall Size= 100.0"W x 60.0"H x 4.33'L with 0.31'Overlap Cap Storage= +35.7 cf x 2 x 16 rows = 1, 142.4 cf 100.0" Wide + 7.0" Spacing = 107.0" C -C Row Spacing 31 Chambers/Row x 4.02'Long +2.56'Cap Length x 2 = 129.89'Row Length +12.0" End Stone x 2 131.89'Base Length 16 Rows x 100.0"Wide + 7.0" Spacing x 15 + 12.0" Side Stone x 2 = 144.08' Base Width 18.0" Base + 60.0" Chamber Height + 6.0" Cover = 7.00' Field Height 496 Chambers x 106.5 Gf + 35.7 cf Cap Volume x 2 x 16 Rows = 53,961.7 Gf Chamber Storage 133,023.7 cf Field - 53,961.7 Gf Chambers = 79,062.1 cf Stone x 40.0% Voids = 31,624.8 cf Stone Storage Chamber Storage + Stone Storage = 85,586.5 cf = 1.965 af Overall Storage Efficiency = 64.3% 496 Chambers 4,926.8 cy Field 2,928.2 cy Stone MMW North Park Lot Add 9-1-15 Type // 24 -hr 100 year Rainfall= 7 29 " Prepared by Microsoft Printed 9/8/2015 HydroCAD010.00-12 s/n06O27 Q2014 HydroCAD Software Solutions LLC Page 44 Pond 3P: Proposed New Underground Storm Chambers Hydrograph 0 Inlo� F45...59 efs O�tfl. Inflow Area=14.391 ac E Dis�rded 50 W Primary 45 Peak Elev=1,045.89' 411( Storage=1.946 af 35� 30- 25- 20� 11.03 cis 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 Tim (houm) MMW North Park Lot Add 9-1-15 Prepared by Microsoft HydroCACE) 10.00-12 s/n 06027 @ 2014 F Type // 24 -hr Abstraction Rainfall= 1. 10 " Printed 9/8/2015 Time span=0.00-72.00 hrs, dt=0.01 hrs, 7201 points Runoff by SCS TR -20 method, UH=SCS, Weighted -CIN Reach routing by Dyn-Stor-Ind method - Pond routing by Dyn-Stor-Ind method Subcatchment Al: East Grass Fields & Tennis Runoff Area=6.467 ac 10.65% Impervious Runoff Depth=0.00" Flow Length=400' Tc=45.0 min CN=65 Runoff=0.00 cfs 0.000 af Subcatchment A2: West Grass & Tennis Courts Runoff Area=0.809 ac 74.17% Impervious Runoff Depth=0.31" Flow Length=600' Tc=30.6 min CN=88 Runoff =0.1 9 cfs 0.021 af Subcatchment A3: Main Parking Lot Runoff Area=6.321 ac 33.38% Impervious Runoff Depth=0.03" Flow Length=350' Tc=l 0.8 min CN=73 Runoff =0.02 cfs 0.017 af Suboatchment A4: Proposed Parking Lot & Runoff Area=0.794 ac 76.70% Impervious Runoff Depth=0.35" Flow Length=430' Tc=21.5 min CN=89 Runoff=0.28 cfs 0.023 af Pond 1: Peak Elev--1,043.73' Inflow=0.02 cfs 0.017 af 24.0" Round Culvert n=0.015 L=35.0' S=-0.0049 T Outflow=0.02 cfs 0,017 af Pond 1P: East Filtration Swale Peak Elev--1,059.00' Storage=0.000 af Inflow=0.00 cfs 0.000 af Discarded=0.00 cfs 0.000 af Primary --0.00 cfs 0.000 af Outflow=0.00 cfs 0.000 alf Pond 2P: West Filtration Swale Peak Elev--1,050.49' Storage=0.01 1 af Inflow=0.19 cfs 0.021 af Discarded=0.01 cfs 0.021 af Primary=0.00 cfs 0.000 af Outflow=0.01 cl's 0.021 af Pond 3P: Proposed New Underground Storm Peak Elev--1,039.05' Storage=0.010 af Inflow=0.28 cfs 0.040 af Discarded=0.04 cfs 0.040 af Primary --0.00 cfs 0.000 af Outflow=0.04 cfs 0.040 af Total Runoff Area = 14.391 ac Runoff Volume = 0.061 af Average Runoff Depth = 0.05" 72.15% Pervious = 10.383 ac 27.85% Impervious = 4.008 ac MMW North Park Lot Add 9-1-15 Type // 24 -hr Abstraction Rainfall=l. 10" Prepared by Microsoft Printed 9/812015 HydroCAD010.00-12 s/nO6O27 @2014 HydroCAD Software Solutions LLC Page 46 Summary for Subcatchment Al: East Grass Fields & Tennis Cts Runoff 0.00 cfs @ 24.25 hrs, Volume= 0.000 af, Depth= 0.00" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr Abstraction Rainfall=1.10" Area (ac) CN DescriDtion 5.778 61 >75% Grass cover, Good, HSG B 0.689 98 Paved parking, HSG A 6.467 65 Weighted Average 5.778 89.35% Pervious Area 0.689 10.65% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 43.6 300 0.0150 0.11 Sheet Flow, Existing grass play field Runoff Volume=0.000 af 0.000- Grass: Dense n= 0.240 P2= 2.50" 1.4 100 0.0200 1.22 Sheet Flow, Paved Path Smoothsurfaces n=0.011 P2=2.50" 45.0 400 Total Subcatchment Al: East Grass Fields & Tennis Cts 0.001- 0-0 0.001- Type 11 24 -hr 0.000- Abstraction Rainfall=11.10" 0.000 � Runoff Area=6.467 ac Runoff Volume=0.000 af 0.000- 1 Runoff Depth=0.00" 41,0.000 Flow Length=400' ODOO Tc=45.0 min 0.000 CN=65 2 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Tim (houm) MMW North Park Lot Add 9-1-15 Type // 24 -hr Abstraction Rainfall= 1. 10" Prepared by Microsoft Printed 9/8/2015 HydroCAD(g) 10.00-12 s1n 06027 @ 2014 HydroCAD Software Solutons LLC Page 47 Summary for Subcatchment A2: West Grass & Tennis Courts Runoff 0.19cfs@ 12.28hrs, Volume= 0.021af, Depth= 0.31" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr Abstraction Rainfall=11.10" Area (ac) CN DescriDtion 0.600 98 Path 0.209 61 >75% Grass cover, Good, HSG B 0.809 88 Weighted Average 0.209 25.83% Pervious Area 0.600 74.17% Impervious Area Tc Length Slope Velocity Capacity Description 3.7 300 0.0150 1.35 Sheet Flow, Minnetonka HS SmoothsurfaGes n=0.011 P2=2.50" 26.9 300 0.0500 0.19 Sheet Flow, West Grass Grass: Dense n= 0.240 P2= 2.50" 30.6 600 Total Subcatchment A2: West Grass & Tennis Courts Hydrograph 0.21 0.2 -- [0.19 efs 0.19 Type 11 24 -hr 0.18 0.17 Abstraction Rainfall=1.10" 0.16 Runoff Area=0.809 ac 0.15 0.14 Runoff Volume=0.021 af 013 4! 0.12 Runoff Depth=0.31" OA1 0.1 Flow Length=600' 0.09 Tc=30.6 min 0.08 0.07 CN=88 0.01 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Tim (houm) MMW North Park Lot Add 9-1 -15 Type il 24 -hr Abstraction Rainfafi=l. 10" Prepared by Microsoft Printed 9/8f2015 HydroCADO 10.00-12 sin 06027 @ 2014 HydroCAD Software Solutions LLC PaQe 48 Summary for Subcatchment A3: Main Parking Lot Runoff 0.02 cfs @ 13.02 hrs, Volume= 0.017af, Depth= 0.03" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr Abstraction Rainfall=1.10" Area fac) CN Descriotion 2.110 98 Parking Lot 4.211 61 >75% Grass cover, Good, HSG B 6.321 73 Weighted Average 4.211 66.62% Pervious Area 2.110 33.38% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (fVft) (ft/sec) (Cfs) 4.4 300 0.0100 1.15 Sheet Flow, Minnetonka HS 0.014 I Flow Length=350' M 0.012 Smoothsurfaces n=0.011 P2=2.50" 6.4 50 0.0200 0.13 Sheet Flow, 0.006 Grass:Short n=0.150 P2=2.50" ilfl[-�Mfmrom SubcatchmentA3: Main Parking Lot Hydrograph 0.024 : Type 11 24 -hr 0.022- Abstraction Rainfall=1.10" U2- Runoff Area=6.321 ac 0.018 � Runoff Volume=0.017 af 0.016- U Runoff Depth=0.03" 0.014 I Flow Length=350' M 0.012 Tc=10.8 min 0.01 CN=73 0.008 0.006 0.004 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 Tim (houm) 687072 MMW North Park Lot Add 9-1 -15 Type // 24 -hr Abstraction Rainfafi=f. 10" Prepared by Microsoft Printed 9/8/2015 HydroCAD@10.00-12 s/nO6O27 @2014 HydroCAD Software Solutions LLC Paae 49 Summary for Subcatchment A4: Proposed Parking Lot & Widened Drive Runoff 0.28 ds @ 12.16 hrs, Volume= 0.023 af, Depth= 0.35" Runoff by SCS TR -20 method, UH=SCS, Weighted -CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Type 11 24 -hr Abstraction Rainfall=11.110" Area (ac) CN Description 0.609 98 Parking Lot 0.185 61 >75% Grass cover. Good. HSG B 0.794 89 Weighted Average 0.185 23.30% Pervious Area 0.609 76.70% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 3.8 250 0.0100 1.11 Sheet Flow, Minnetonka HS Smoothsurfaces n=0.011 P2=2.50" 17.7 180 0.0200 0.17 Sheet Flow, n=0.150 P2=2.50" 21.5 430 Total Subcatchment A4: Proposed Parking Lot& Widened Drive 0.31 1 FO -28 cfs F 0.18 a 0.16 0.14 0.12 0.1 Hydrograph Type 11 24 -hr Abstraction Rainfall=1.10" Runoff Area=0.794 ac Runoff Volume=0.023 af Runoff Depth=0.35" Flow Length=430' Tc=21.5 min CN=89 0 2 4 6 8 10 12 14 16 16 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 Tim (houm) MMW North Park Lot Add 9-1-15 PreDared bv Microsoft Type// 24 -hr Abstraction Rainfafi= 1. 10" Printed 9/8/2015 Surnniary for Pond 1: [571 Hint: Peaked at 1,043.73'(Flood elevation advised) Inflow Area 6.321 ac, 33.38% Impervious, Inflow Depth = 0.03" for Abstraction event Inflow 0.02 cfs @ 13.02 hrs, Volume= 0.017 af Outflow 0.02 ds @ 13.02 hrs, Volume= 0.017 af, Atten= 0%, Lag= 0.0 min Primary 0.02 cfs @ 13.02 hrs, Volume= 0.017 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,043.73'@ 13.02 hrs Device Routing Invert Outlet Devices #1 Primary 1,043.6r 24.0" Round Culvert L= 35.0' RCP, sq.cut end projecting, Ke= 0.500 Inlet/ Outlet Invert= 1,043.50'/ 1,043.67' S= -0.0049'P Cc=0.900 n= 0.015 Concrete sewer w/manholes & inlets, Flow Area= 3.14 sf Primary OutFlow Max=0.02 cfs @ 13.02 hrs HW=1,043.73' TW=1,039.05' (Dynamic Tailwater) '�-11--Culverlt (Inlet Controls 0.02 cfs @ 0.85 fps) Pond 1: U.Ub� U.. Inflow Area=6.321 ac 0.024- OM2� Peak Elev=l 043.73' 0.02- 24.011 0.018- Round Culvert 0.016- 0014 n=0.01 5 w �0012 L=35.0' 0.01 ----1 1 S=-0.0049'/' 0.002 0 2 4 6 8 1012141618202224262830323436384042444648505254565860626466687072 Tim (houm) Fill 10 Pn�ry I MMW North Park Lot Add 9-1-15 Prepared by Microsoft HydroCAD@) 10.00-12 stn 06027 @ 2014 F Type// 24 -hr Abstraction Rainfall= 1. 10" Printed 9/812015 Summary for Pond 1P: East Filtration Swale Inflow Area 6.467 ac, 10.65% Impervious, Inflow Depth = 0.00" for Abstraction event Inflow 0.00 cfs @ 24.25 hrs, Volume= 0.000 af outflow 0.00 cfs @ 25.84 hrs, Volurne= 0.000 af, Atten= 99%, Lag= 95.5 min Discarded 0.00 Gfs @ 25.84 hrs, Volume= 0.000 af Primary 0.00 Gfs @ 0.00 hrs, Volume= 0.000 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,059.00'@ 25.84 hrs Surf.Area=0.040ac Storage=0.000af Plug -Flow detention time= 1,329.6 min calculated for 0.000 af (28% of inflow) Center -of -Mass det. time= 1,289.6 min ( 2,733.8 - 1,444.3 ) Volume Invert Avail.Storage Storage Description #1 1,059.00, 0.343af Custom Stage Data (Prismatic) Listed below (Recalc) Elevation Surf.Area Inc.Store Cum.Store (feet) (acres) (acre-feet) (acre-feet) 1,059.00 0.040 0.000 0.000 1,060.00 0.100 0.070 0.070 1,061.00 0.447 0.273 0.343 Device Routing Invert Outlet Devices #1 Primary 1,055.00' 18.0" Round Culvert L= 140.0' RCP, mitered to conform to fill, Ke= 0.700 Inlet/ Outlet Invert= 1,055.00'/ 1,046.00' S=0.0643'P Cc=0.900 n=0.010 PVC, smooth interior, FlowArea=1.77sf #2 Device 1 1,060.40' 24.0"Hori7-Orifice/Grate C=0.600 Limited to weir flow at low heads #3 Discarded 1,059.00' 0.500 irdhr Exfiltration over Surface area from 1,059.W - 1,060.50' Excluded Surface area = 0.040 ac Phase -In= 0.01' Discarded OutRow Max=0.00 cfs @ 25.84 hrs HW=1,059.00' (Free Discharge) t--3--Exfiltration (ExAltration Controls 0.00 cfs) Primary OutFlow Max=0.00 cfs @ 0.00 hrs HW=1,059.00' TW=1,039.00' (Dynamic Tailwater) t __J=Culvert (Passes 0.00 cfs of 13.53 cl's potential flow) t--2--Orifice/Grate ( Controls 0.00 cfs) MMW North Park Lot Add 9-1-15 Type// 24 -hr Abstraction Rainfall= 1. 10" Prepared by Microsoft Printed 9/8/2015 HydroCADCD10.00-12 s/n06O27 @2014 HydroCAD Software Sdutions LLC Page 52 Pond IP: East Filtration Swale Hydrograph 0 2 4 6 8 1012141618202224262830323436384042444648505254565860626466687072 Time (houni) M0 Inflow L outflow [] Dis,zarded 0 Primary MMW North Park Lot Add 9-1-15 Type// 24 -hr Abstraction Rainfall= 1. 10" Prepared by Microsoft Printed 9/8/2015 HydroCAD@)10.00-12 s/nO6O27 @2014 HydroCAD Software Solutions LLC Page 53 Summary for Pond 2P: West Filtration Swale Inflow Area 0.809 ac, 74.17% Impervious, Inflow Depth = 0.31" for Abstraction event Inflow 0. 19 cfs @ 12.28 hrs, Volume= 0.021 af Outflow 0.01 cfs @ 15.87 hrs, Volume= 0.021 af, Atten= 93%, Lag= 216.0 min Discarded 0.01 ds @ 15.87 hrs, Volume= 0.021 af Primary 0.00 Gfs @ 0.00 hrs, Volume= 0.000 af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,050.49'@ 15.87hrs Surf.Area=0.027ac Storage=0.011af Plug -Flow detention time= 423.8 min calculated for 0.021 af (100% of inflow) Center -of -Mass det. time= 423.8 min ( 1,313.5 - 889.7 ) Volume Invert Avail.Storage Storage Description #1 1,050.00' 0.038 af Custom Stage Data (Prismatic) Listed below (ReGale) Elevation Surf.Area Inc.Store Cum.Store (feet) (acres) (acre-feet) (acre-feet) 1,050.00 0.018 0.000 0.000 1,050.50 0.027 0.011 0.011 1,051.00 0.082 0.027 0.038 Device Routing Invert Outlet Devices #1 Primary 1,046.50' 12.0" Round Culvert L= 30.0' RCP, mitered to conform to fill, Ke= 0.700 Inlet/ Outlet Invert= 1,046.50'/ 1,046.00' S=0.0167'P Cc=0.900 n=0.010 PVC, smooth interior, FlowArea=0.79sf #2 Device 1 1,050.90' 24.0" Vert. Orifice/Grate C= 0.600 #3 Discarded 1,050.00' 0.500 in/hr ExHitration over Horizontal area from 1,049.00' - 1,050.90' Conductivity to Groundwater Elevation = 0.00' Excluded Horizontal area = 0.000 ac Phase -In= 0.01' Discarded OutFlow Max=0.01 ds @ 15.87 hrs HW=1,050.49' (Free Discharge) 't-3--ExIlliltration ( Controls 0.01 cfs) Primary OutFlow Max=0.00 Gfs @ 0.00 hrs HW=1,050.00' TW=1,039.00' (Dynamic Tailwater) 't--l--Culvert (Passes 0.00 cfs of 5.78 cfs potential flow) '�-2--OrificelGrate ( Controls 0.00 cfs) MMW North Park Lot Add 9-1-15 Type// 24 -hr Abstraction Rainfall= 1. 10" Prepared by Microsoft Printed 9/8/2015 HydroCAM10.00-12 s/nO6O27 @2014 HydroCAD Software Solutions LLC Page 54 0.1 0.1 0.14 0.12 0.1 Pond 2P: West Filtration Swale Hydrograph 0 lnflm I Outilm F1 D[scarded Inflow Area=().809 ac E Primary Peak Elev=1,050.49' Storage=0.01 1 af 3234363840 42" 4648 505254 565860 62646668 7072 Tim (houm) MMW North Park Lot Add 9-1-15 Type // 24 -hr Abstraction Rainfafi=l. 10" Prepared by Microsoft Printed 9/8/2015 HydroCAD@)10.00-12 s/no6027 @2014 HydroCAD Software Solutions LLC Page 55 Summary for Pond 3P: Proposed New Underground Storm Chambers [871 Warning: Oscillations may require smaller dt or Finer Routing (severity --164) Inflow Area 14.391 ac, 27.85% Impervious, Inflow Depth = 0.03" for Abstraction event Inflow 0.28 afs @ 12.16 hrs, Volume= 0.040 af Outflow 0.04 cfs @ 14.01 hrs, Volume= 0.040 af, Atten= 84%, Lag= 110.8 min Discarded 0.04 cfs @ 14.01 hrs, Volume= 0.040 af Primary 0.00 cfs @ 0.00 hrs, Volume= O.OGO af Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs Peak Elev= 1,039.05' @ 14.01 hrs Surf.Area= 0.436 ac Storage= 0.010 af Plug -Flow detention time= (not calculated: outflow precedes inflow) Center -of -Mass det. time= 89.6 min ( 1,038.7 - 949.2 ) Volume Invert Avail.Storage Storage Description #1A 1,039.00' 0.726 af 1".08W x 131.WL x 7.00'H Field A 3.054 af Overall - 1.239 af Embedded = 1.815 af x 40.0% Voids #2A 1,040.50' 1.239 af ADS - StormTech MC -4500 +Cap x 496 Inside #1 Effe�tive Size= 90.4"W x 60.0"H => 26.46 sf x 4.03'L = 106.5 d Overall Size= 100.0"W x 60.0"H x 4.33'L with 0.31'Overlap 16 Rows of 31 Chambers Cap Storage= +35.7 cf x 2 x 16 rows = 1,142.4 cf 1.965 af Total Available Storage Storage Group A created with Chamber Wizard Device Routing Invert Outlet Devices #1 Primary 1,043.00' 18.0" Round Culvert L= 140.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet/ Outlet Invert= 1,043.00'/ 1,040.00' S=0.0214'P Cc=0.900 n=0.015 Concrete sewer w/manholes & inlets, FlowArea=1.77sf #2 Discarded 1,039.00' 0.100 in/hr ExlFiltration over Surface area Conductivity to Groundwater Elevation = 0.00' Discarded OutFlow Max=0.04 cfs @ 14.01 hrs HW=1,039.05' (Free Discharge) t--2--Exriltration ( Controls 0.04 Gfs) Primary OutFlow Max=0.00 cfs @ 0.00 hrs HW=1,039.00' (Free Discharge) 't-'-1--CuIvert ( Controls 0.00 cfs) MMW North Park Lot Add 9-1-16 Type 11 24 -hr Abstraction Rainfall=l. 10" Prepared by Microsoft Printed 9/8/2015 HydroCAD@)10.00-12 sIn06027 02014 HydroCAD Software SolubonsLLC Paae 56 Pond 3P: Proposed New Underground Storm Chambers - Chamber Nzard Field A Chamber Model = ADS—StormTech MC -4500 +Cap (ADS StormTechID MC -4500 Wth end caps) Effective Size= 90.4"W x 60.0"H => 26.46 sf x 4.031 = 106.5 cf Overall Size= 100.0"W x 60.0"H x 4.33'L with 0.31' Overlap Cap Storage= +35.7 cf x 2 x 16 rows = 1, 142.4 cf 100.0" Wide + 7.0" Spacing = 107.0"C -C Row Spacing 31 Chambers/Row x 4.02'Long +2.56'Cap Length x 2 = 129.89'Row Length +12.0" End Stone x 2 131.89'Base Length 16 Rows x 100.0"Wide + 7.0"Spacing x 15 + 12.0" Side Stone x 2 = 144.08'Base Width 18.0" Base + 60.0" Chamber Height + 6.0" Cover = 7.00' Field Height 496 Chambers x 106.5 ef + 35.7 cf Cap Volume x 2 x 16 Rows = 53,961.7 cf Chamber Storage 133,023.7 Gf Field - 53,961.7 cf Chambers = 79,062.1 cf Stone x 40.0% Voids = 31,624.8 Gf Stone Storage Chamber Storage + Stone Storage = 85,586.5 d = 1.965 at Overall Storage Efficiency = 64.3% 496 Chambers 4,926.8 cy Field 2,928.2 cy Stone MMW North Park Lot Add 9-1-15 Type // 24 -hr Abstraction Rainfall= 1. 10" Prepared by Microsoft Printed 9/8/2015 HydroCADO 10.00-12 sin 06027 0 2014 HydroCAD Software Solubons LLC Pacie 57 0.181 1 0.16 0.14 0.1 G.G4 Pond 3P: Proposed New Underground Storm Chambers Hydrograph 0 Inflow Area=14.391 ac D=1d Peak Elev=1,039.05* Storage=0.010 af 0 2 4 6 8 1012141618202224262830323436384042444648505254565860626466687072 Tim (houm) CD1 - ----- - I?IA, 92 GENERAL NOTES: <1 1 �Q7,5 .69 KEYED NOTES: , i , -4 i I I I I I C/yz) 0 5801 Duluth Street i 0 (D REMOVE EXISTING CURB AND GUTTER AS NEEDED FOR WIDENING C) f -4, /V 1 . SITE DATA OBTAINED FROM TOPOGRAPHIC SURVEY PERFORMED BY NUnneapolis, MN OF EXISTING DRIVE. SUNDE LAND SURVEYING DATED DECEMBER 16,2008. 55422 -546-3434 REMOVE EXISTING GRASS AND SUBGRADE SOIL AS NEEDED FOR MATC LI 190 Ph. 763 2. LOCATIONS AND SIZES OF ALL UNDERGROUND UTILITIES SHOWN x CD r)of WIDENING OF EXISTING DRIVE. 1 01 WC) ARE APPROXIMATE ONLY. VERIFY ALL UTILITIES CONTRACTOR INSPEC @ 2015 f---------- --- REMOVE EXISTING BITUMINOUS WALKWAY. 1 C) Cil .6 RESPONSIBLE FOR REPAIR TO ANY DAMAGED UNDERGROUND CfI ; �J \ I �X/ "01 /x UTILITIES. REMOVE EXISTING STONE/GRAVEL AND EARTHWORK AS REQUIRED. bo C:� cy? -Z _a� ------ -- CD, I�D L MH 3, CONTRACTOR RESPONSIBLE FOR LOCATING AND PROTECTING ALL x REMOVE EXISTING FENCE. CP SITE UTILITIES. CONTACT GOPHER STATE ONE CALL AND PRIVATE Consultants: C:) 07 REMOVE ALL EXISTING TREES AND VEGETATION IN SHADED AREA p ------ ----- ON LOCATOR PRIOR TO ANY EXCAVATION. C:) x 0 Co FOR CONSTRUCTION ON NEW PARKING LOT. ------ REMOVE EXISTING GRASS, SUBGRADE SOIL AND DRAIN TILE AS NEEDED x C) 4. ALL CONSTRUCTION MUST COMPLY WITH APPLICABLE ORDINANCES. FOR CONSTRUCTION OF BITUMINOUS WALKWAY. 00 A /YC CD CD J 5. CONTRACTOR SHALL BE RESPONSIBLE FOR AND PAY FOR ALL x---------- DRAIN POND, COORDINATE WITH ENGINEER. EXCAVATE AS REQUIRED. f CONSTRUCTION STAKING. SEE GRADING AND DRAINAGE PLAN AND EXHIBITA. �,D //V w PJ F I 1 > /V Cfi 6. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL CONSTRUCTION REMOVE EXISTING PIPE AND RIP -RAP. x / CD cc (JI 1 < PERMITS. rmu 0 INSTALL SILT FENCE PRIOR TO CONSTRUCTION START. FT] Cu(�o 7. PROTECT EXISTING FACILITIES AND VEGETATION WHICH ARE TO PROVIDE INLET PROTECTION ATALL CATCH BASINIMANHOLES. > REMAIN. RESTORE ALL DISTURBED AREAS, INCLUDING PAVEMENT, 0 REMOVE EXISTING CURB AND GUTTER. C:), 4_� LANDSCAPING, AND LAWN AREAS TO ORIGINAL CONDITION. CD CJ a PLACE BIO -ROLLS ALONG ENTIRE EDGE, APPROX. 290 L.F. X -------- 4�- 1 1 i 8. CONTRACTOR TO SWEEP SITE PAVEMENTS AND ADJACENT STREETS cc) N) Aw 00 '1w AT CONSTRUCTION VEHICLE ACCESS POINTS EACH WORK DAY WITH - CO cil ROCK CONSTRUCTION ENTRANCE PER CITY OF CHANHASSEN DETAIL PICK UP SWEEPER OR EQUAL TO REMOVE ANY ACCUMULATED SOIL (SEE SPECIFICATIONS) X) MATERIAL. AFTER THE POND HAS BEEN COMPLETELY DRAINED THE CONTRACTOR OF SOILS TO EXCAVATE WILL BE DETERMINED PROMPTLY THEREAFTER. THROUGHOUT PROJECT, INCLUDING BUT NOT LIMITED TO STORM (ATY0FCHANHAWE*� CD' WATER STRUCTURES INLET PROTECTION. SHALL CONTACT THE ENGINEER FOR SOILS ASSESSMENT. THE AMOUNT 9. CONTRACTOR SHALL BE RESPONSIBLE FOR EROSION CONTROL THE ORIGINAL DETENTION POND WAS TO HAVE BEEN CONSTRUCTED PER RSCEIVED THE 2003 INSPEC PLAN (SEE EXHIBIT A). X 10. LIMIT AND CONTROL VEHICLE AND EQUIPMENT ACCESS ON EXISTING -- ------------ ------ C SEP 0 8 2015 R) 4�, -C)I"- I - i THE CONTRACTOR'S BID SHALL BE BASED ON THE 2003 PLAN (EXHIBIT A) AND PAVEMENT SYSTEMS. CONTRACTOR IS REQUIRED TO ------------ Y� RESTORE ALL PAVEMENT SYSTEMS DAMAGED DURING THE THESE PLANS. IF ADDITIONAL EXCAVATION BEYOND WHAT WOULD BE REQUIRED Cil ------ 00 CHANHASSENP~W1 PER THE 2003 PLAN FINISHED ELEVATIONS, THE CONTRACTOR MUST PROMPTLY Ir ------- CO Nq cl PROJECT. CONTACT THE ENGINEER AFTER BECOMING AWARE OF THIS TO DETERMINE HOW CD I TO PROCEED AND WHAT PRICE ADJUSTMENTS ARE IN ORDER. ------- - X� Q� C x; -------- (,n 11. ALL EXISTING CATCH BASINS SHALL BE ADJUSTED FOR POSITIVE DRAINAGE AND THE INSIDE COMPLETELY RE -MORTARED, MINIMUM Fu_ 03,\\ TOP OF SLOPE OF NEW PAVEMENT TO BE 1%. Signature: C) (� /�\ I J� -.n ---- ----------- - 'w ___ry ---- 12. ALL DIMENSIONS AND OR QUANTITIES ARE APPROXIMATIONS. THE C? x CONTRACTOR IS RESPONSIBLE FOR VERIFYING. x Cfi 11 00 dD w XN R) 0 -7 // I - x w x EROSION CONTROL NOTES - I'D CD CfI ) x 1. PROTECT EXISTING STORM SEWER INLETS AND SYSTEMS AGAINST J Cf1 SEDIMENTATION AS A RESULT OF CONSTRUCTION RELATED DIRT AND 4�- DEBRIS IN ACCORDANCE WITH SPECIFICATIONS. CD < w X 2. PROVIDE INLET PROTECTION IN ACCORDANCE WITH MN/DOT 3891. Issues and revisions: x x 0 ) �x 0A C1 0 ISSUE LEVEL REVISION: DATE: No.: 00 2- 8 f 3. MAINTAIN ADJACENT PROPERTY, STREETS, AND PAVEMENT CLEAN FROM 1> 4 -7 S CONSTRUCTION CAUSED DIRT AND DEBRIS ON A DAILY BASIS AND ON AN AS 4� x NEEDED BASIS AND AS DIRECTED BY THE ENGINEER, OWNER, OR CITY. MATC Ll C) (J-1 00 NOTES: Ui ru 06 x 1. DIG A 6"X6" TRENCH ALONG7 iE!NTENDED FENCE LINE. x c6 D 0 DEMOLITION AND 2. DRIVE ALL POSTS INTO THE GROUND AT THE 7— CTI DOWNHILL SIDE OF THE TREl"OH. /X EROSION CONTROL PLAN LLI C -D ZA 3. WIRE FENCING PER HENNEPIN COUNTY (M)o 0 15, 30' 60' CONSERVATION DISTRICT EROS`1ON AND METAL T- POST .G K70 A SEDIMENT CONTROL MANUAL. MESH MUST BE A NORTH 2 MINIMUM OF 2" INTO THE GROUND AND NO R MORE THAN 36" ABOVE THE ORIGINAL GROUND 5 SCALE: 1 30'-0" SURFACE. WIRE MESH(14-1/2" MIN. GA C1 Client: Z. 4. LAY OUT SILT FENCE ON THE UPHILL SIDE - - — ----- -- ----------------- - CD ALONG THE FENCE LINE AND BACK FILL. V< < ------------ ----------- - ---------------- - - - ----------- "MAX FILTER FABRIC (36 MINNETONKA V -------------------- -- ------- tDvu I --- ------------ 5. POSTS MAY BE SPACED UP TO 4 FEET APART IF H' C? �6 ------------------ - WIRE MESH IS NOT USED TO SUPPORT TH z CD m *-/ 0H_AfN_____L FABRIC. IF WIRE MESH IS USED TO SUPPO T -- ----- - -- - ----------------------------------- -----FEN CE -------------- - - --- - THE FABRIC, POSTS MAY BE SPACED UP TO 8 SCHOOLS ---- INK < CL FEET APART. BACK FILL 6" X 6" V------------- -------- V �D 0 6. REMOVE SILT FENCE AND RESTORE ALL TRENCH x . ..... — ----------- 0 f\J 0 x 0 AFFECTED AREAS AFTER TURF IS ESTABLISHED, C BUT NOT BEFORE APPROVAL FROM ENGINEER. cf) z CD oil_ CD o-\ i, _1J * 1'�, I�OtA of IV Qxyl` f CJ') 031A x I -ItD C FT1 5 CO Q) WEST 7 E x ..001 FTI x x i i 1,, MIDDLE SCHOOL z x 4�- 0 < I �A I ; I U J 1 1 z C__ 0 0 ---- X ;KIP C/) C)l 0 ---------------- (T� Project title: x Z I 1\ z ��.Oo b4 X 0.0 0 0 2016 STORM DRAIN 9 0 �)5z w < <K < IMPROVEMENTSAND ZZ_ 0 u- S EXISTING SOIL LLI ILT FENCE DETAIL PARKING LOT ADDITION 71 NO SCALE 0 Q) 6421 HAZELTINE BOULEVARD a- 11 0 CP 0 x 0 x DEMOLITION AND EXCELSIOR, MINNESOTA 55331 x CD (J] x 7 C)i 0 0 EROSION CONTROL PLAN Sheet content: -to-\ �C) 0 x cf) z 0 10, 20' 40' (J] 0 0 � \ 0 C 0 CO 30 NORTH DEMOLITION AND (o Cn 0 01 LSCALE: 1 2 -0.1 7`0 ------------- EROSION CONTROL PLAN CATCH BASIN/MANHOLE SCHEDULE CB/MH TYPE TOP RIM INLET FRAME INV. ELEV. INV. ELEV. # ELEV. AND GRATE IN OUT 1043.51 1 48" DIA. CONC. 1052.40 SOLID CONTRACTOR 1043.50 MONOLITHIC TO VERIFY 1043.20 (N) 2 60" DIA. CONC. 1053.00 SOLID 1043.05(S) 1043.00 MONOLITHIC 1048.60 (E) METAL 3 30" NYLOPLAST 1052.20 STD.CB 1049.20 1049.20 INLET 4 60" DIA. CONC. 1051.00 SOLID 1043.80 (W) 1043.76 MONOLITHIC 1046.20 (N) 48" DIA CONC NEENAH R-2573 5 MONOLITHIC' 1048-50 FRAME AND 1044.48 TYPE C GRATE 72" DIA. CONC, 1043.00 (N) 6 1053.00 SOLID 1043.00 MONOLITHIC 1043.00 (W) 7 48" DIA. CONC. 1057.50 SOLID 1043.00 1040.00 MONOLITHIC -Z METAL 8 30" N T YLOP S1 1051.00 STD.CB 1048.00 1048.00 I INLET TOP OF CONIC. WEIR 1043.50 W X 00 x 0 tv FU 00, /011, x CD -(0 Co CD w 00 CD Cil TC[ > FTI F_ GENERAL NOTES: 1. CONTRACTOR RESPONSIBLE FOR LOCATING AND PROTECTING ALL PUBLIC AND PRIVATE SITE UTILITIES. CONTACT GOPHER STATE ONE CALL AND PRIVATE LOCATOR PRIOR TO PERFORMING ANY WORK. CONTRACTOR IS RESPONSIBLE FOR REPAIRING AND RESTORING ANY DAMAGED PROPERTY. 2. ALL CONSTRUCTION MUST COMPLY WITH APPLICABLE CODES AND ORDINANCES. 3. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL CONSTRUCTION PERMITS AND CONSTRUCTION STAKING. 4. PROTECT EXISTING FACILITIES, UTILITIES, TREES, AND VEGETATION WHICH ARE TO REMAIN. RESTORE ALL DISTURBED AREAS, INCLUDING PAVEMENTS, LANDSCAPING, AND LAWN AREAS TO ORIGINAL CONDITION. 5. SWEEP SITE PAVEMENTS AND ADJACENT STREETS AT CONSTRUCTION VEHICLE ACCESS POINTS AT COMPLETION OF PROJECT. 6. ALL DIMENSIONS AND/OR QUANTITIES ARE APPROXIMATIONS. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING. 7. CONTRACTOR TO RESTRIPE ALL PARKING LOTS AND DRIVES ON CAMPUS UPON COMPLETION OF PROJECT TO ORIGINAL CONDITIONS, INCLUDING BUT NOT LIMITED TO PARKING SPACES, CURBING, AND OTHER EXISTING DEMARCATION. CD 8. PROPERLY RE -INSTALL ALL SIGNS AND FENCE REQUIRED TO BE X b C) REMOVED AFTER COMPLETION OF PAVEMENT REHABILITATION. C . D 00 0"� .44 CI), C)"I 9. FINISH GRADE SHALL BE ADJUSTED TO ACHIEVE POSITIVE DRAINAGE 0000 00 Co- CD WITH MINIMUM SLOPE OF 1% OR MORE. x 7 1 "N" DENOTES NEW FINISHED GRADEITOP OF PAVEMENT CONTOURS 0. ALL OTHER ELEVATIONS ARE EXISTING UNLESS NOTED OTHERWISE. CD 11. 0 INDICATES TOP OF FINISHED GRADE SPOT ELEVATIONS. 4�_ 12 x &]ST. CbRB AND GUTTE C5 BE REMOVED,(APPROX. CD KEYED NOTES: 290 L.F.) NO CJ 0 x DIA. CONCRETE MONOLITHIC CATCH BASIN/MANHOLE #1. �D �D NEW48 CD Cil DIA. CONCRETE MONOLITHIC CATCH BASIN/MANHOLE #2. Q NEW60 CD DIA. NYLOPLAST CATCH BASIN/MANHOLE #3. NEW 30 C, x X NEW 48" DIA. CONCRETE MONOLITHIC CATCH BASIN/MANHOLE #4. '9' 00 CD 7 C DIA. CONCRETE MONOLITHIC CATCH BASINIMANHOLE #5. 4�- 0 NEW48 x 1049.2 NC �,D 1048.7 NG' NEW 72" DIA. CONCRETE MONOLITHIC CATCH BASIN/MANHOLE #6. 00 046 `N-01;�1047N- ------ NEW 48" DIA. CONCRETE MONOLITHIC CATCH BASIN/MANHOLE #7. L6 045 N DIA. NYLOPLAST CATCH BASIN/MANHOLE #8. CD NEW 30 j NEW 18" DIA. HOPE PIPE, (APPROX. 20 L.F. TOTAL) w 04,> A( /V. DIA. HDPE PIPE, (APPROX. 110 L.F. TOTAL) NEW 24 z -'�70 NEW 30" DIA. HDPE PIPE. (APPROX. 90 L.F. TOTAL) V _**�70. IV> 19 NEW UNDERGROUND STORM CHAMBERS. (SEE STORM CHAMBERS PLAN- C4) ----------- -- ------------ CD :!!��060 NEW 30" HDPE MANIFOLD PIPES (APPROX. 225 L.F. TOTAL). < < ------ I ---- I ---------- - A-% --------------- ** ------- '15 NEW 6"DIA. HOPE PERFORATED PIPE IN SOCK, APPROX. 150 L.F. 00 - ------------------------ TOTAL, SLOPE 0.5% TO NEW CATCH BASIN/MANHOLE. ---------------------------------------------------- NEW 12" DIA. HOPE PIPE, APPROX. 135 L.F. 4�, CL (D x TRANSITION FROM SURMOUNTABLE CURB TO 136-18 CURB AND w 6 0 N)o GUTTER. �,7 NEW 136-18 CONCRETE CURB AND GUTTER. v) z m 45 NEW SURMOUNTABLE CURB. L J 9 45 NEW 8" DIA HDPE PIPE, APPROX. 90 L.F. FTI x 40 NEW BITUMINOUS PATH (SHADED). 5801 Duluth Street Minneapolis, MN 55422 Ph. 763-546-3434 INSPEC (�) 2015 Consultants: Signature: Issues and revisions: ISSUE LEVEL / REVISION: DATE: No.: Client: MINNETONKA SCHOOLS WEST MIDDLE SCHOOL Project title: 2016 STORM DRAIN IMPROVEMENTS AND PARKING LOT ADDITION 6421 HAZELTINE BOULEVARD EXCELSIOR, MINNESOTA 55331 Sheet content. GRADING AND DRAINAGE PLAN DATE: 9-1-15 CLIENT PROJECT No.: INSPEC PROJECT No.: PROJECT MGR: CB DRAWN BY: BT CHECKED BY: 1313 Sheet No.: C2SCANNED L6 Ob cl) 0 z z w 0 u - w X: L 0 0 ID m .2 2 C5 4 44 i� C :5:5 27' C5 01 L S -A 41� 3 C5 163.25' 3 91 4 75 6 75 4k 91 164' 24' MATCH LINE LAYOUT PLAN 0 10, 20' 40' 1 SCALE: 1" 20'-0" 5801 Duluth Street Minneapolis, MIN 55422 t000. Ph. 763-546-3434 INSPEC 2015 Consultants: Signature: Issues and revisions: ISSUE LEVEL REVISION: DATE: No.: Client: MINNETONKA SCHOOLS WEST MIDDLE SCHOOL Project title: 2016 STORM DRAIN IMPROVEMENTS AND PARKING LOT ADDITION 6421 HAZELTINE BOULEVARD EXCELSIOR, MINNESOTA 55331 Sheet content: LAYOUT PLAN DATE: 9-1-15 CLIENT PROJECT No.: INSPEC PROJECT No.: PROJECT MGR: CB DRAWN BY: BT CHECKED BY: BB Sheet No.: GENERAL NOTES ALL DESIGN SPECIFICATIONS FOR THE STORM WATER CHAMBERS SHALL BE IN ACCORDANCE WITH THE MANUFACTURERS DESIGN SPECIFICATIONS. THE CONTRACTOR IS ADVISED TO REVIEW AND UB=NDERSDTAND THE INSTALLATION REQUIREMENTS PRIOR TO BEGINNING SYSTEM INSTALLATION. CHAMBERS SHALL MEET THE DESIGN REQUIREMENTS AND LOAD FACTORS SPECIFIED IN SECTION 12.12 OF THE LATEST EDITION OF THE AASHTO _RFD BRIDGE DESIGN SPECIFICATIONS. MC -4500 CHAM TO OUTLET CONTROL STRUCTURE 18" OUTLET PIPE INV- 104300 SECTION B -B SECTION A -A OUTLET ELEVATIONS NO SCALE STORMTE, CHAMBER SHALL MEET ASTM F 2418-05 ISOLATOR "STANDARD SPECIFICATION FOR POLYPROPYLENE �CORRUGATED WALL STORMWATER NEW 4" BITUMINOUS PAVEMENT OPIECTION CHAMBERS". OVER B" BASE AGGREGATE 3 C(E4A- 2 INCH N, ANGULAR GRANULAR WELL GRADED SOIL/AGGREGATE STONE MIXTURES' �35% FINES. COMPACT IN 6" LIFTS TO 95% PR CTOR DENSITY. SEE THE TABLE AASHTO M2811 CLASS 2 OF ACCEPTABLE FILL MATERIALS, AS REQUIRED NON -WOVEN GEOTEXTILE (SEE GRADING AND DRAINAGE PLAN) NEW 30" TOP OF SC -740 HOPE DIN PIPE GRADE CAP NEW 72- (MH MANHOLE 1040.50 THIS CROSS SECT10N DETAILS THE REQUIREMENTS NECESSARY TO SATISFY THE LOAD FACTORS SPECIFIED INTHE AASHTO LRF3 BRIDGE DESIGN SPECIFICATIONS SECTION 12.12 FOR EARTH AND LIVE LOADS WITH CONSIDERAT10N FOR IMPACT AND MULTIPLE VRHICLE PRESENCES. TYP. STANDARD MC -4500 CROSS SECTI ON NO SCALE TOP OF GRADE ELEV. APPROX. 956.00 MC -4500 30" INLET PIPE INV. = 1043.00 ACE MINIMUM 12.5' OF AASHTO 88 CLASS 1 WOVEN GEOTEXTILE ER BEDDING STONE FOR SCOUR OTECTIONAT ALL CHAMBER INLET WS 30" HDPE DW PIPE (TYP. 4 LOCATIONS) 30 tANIFOILD INV. 10 300 AASHTO M43 8OTTEOLMEVMH= 1041.00 INV. COMPACTION/DENSITY MATERIAL LOCATION DESCRIPTION 30" MANIFOLD PIPE DESIGNATION B -B INV. ELEV. = 1043.00 BOTTOM OF CHAMBERS ELEV. = 1040.50 I N LET ELEVATI ON S SOILS OR PER ENGINEER'S PLANS. N/A N/A PREPARE PER SPECIFICATIONS. BOTTOM OF FOUNDATIO CHECK PLANS FOR PAVEMENT SUBGRADE STONE ELEV. 1039.00 NO SCALE MC -4500 CHAMBER LAYOUT NO SCALE SEE GRADING AND DRAINAGE PLAN, SHEET C-2 PROPOSED LAYOUT (496� STORMTECH MC -4500 CHAMBERS INST LLED NTH 6" COVER STONE, 18" BASE STONE, 40% STONE VOID INSTALLED SYSTEM VOLUME (PERIMETER STONE INCLUDED) 85,586.5 CF FABRICATED END CAP FOR 30" INLET PIPE STORMTECH ISOLATOR ROW FABRICATED END CAP 30" PIPE INTO ISOLATOR ROW AND ALL CHAMBERS PIPE INV. 947.70 COVER ENTIRE ROW NTH AASHTO CLASS 2 NON -WOVEN GEOTEXT11LE OR EQUAL SC -740: 8' WIDE STRIP AASHTO M288 CLASS 1 WOVEN GEOTEXTLE OR EQUAL, BETWEEN FOUNDATION STONE AND CHAMBERS SC -740 5-6" WOE STRIP ISOLATOR NO SCALE MANHOLE OVERFLOW ECCENTF HEADER PLACE MINIMUM 12.5' AASHTO M288 CLASS WOVEN GEOTEXTLE 0 BEDDING STONE FOR PROTECT10N AT ALL INLET ROWS. MC_ END ROW TT)ROFILE VIEW MC -4500 END CAP ORMTECH DILATOR ROW MC -4500 CHAMBERS TIM ISOLATOR ROW MANIFOLD NO SCALE ACCEPTABLE FILL MATERIALS: STORM WATER CHAMBER SYSTEMS PLEASE NOTE: THE USTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN, ANGULAR. FOR EXAMPLE, THE STONE MUST BE SPECIFIED AS CLEAN, CRUSHED, ANGULAR No. 4 STONE. STORMTECH RECOMMENDS HARDNESS AND DURABIUTY CRITERIA FOR USE OF RECYCLED CONCRETE IN A AND B LOCATIONS. STORM WATER CHAMBERS ACCEPTABLE MATERIALS NO SCALE 5801 Duluth Street Minneapolis, MN 55422 C11111111111111. Ph. 763-546-3434 INSPEC (9) 2015 Consultants: Signature: Issues and revisions: ISSUE LEVEL/ REVISION: DATE: No.: Client: MINNETONKA SCHOOLS WEST MIDDLE SCHOOL Project title: 2016 STORM DRAIN IMPROVEMENTS AND PARKING LOT ADDITION 6421 HAZELTINE BOULEVARD EXCELSIOR, MINNESOTA 55331 Sheet content: STORM CHAMBER DETAILS DATE: 9-1-15 CLIENT PROJECT No.: INSPEC PROJECT No.: AASHTO M43 AASHTO M145 COMPACTION/DENSITY MATERIAL LOCATION DESCRIPTION DESIGNATION DESIGNATION REQUIREMENT ANY SOIL/ROCK MATERIALS, NATIVE FILL MATERIAL FROM 18" TO SOILS OR PER ENGINEER'S PLANS. N/A N/A PREPARE PER SPECIFICATIONS. GRADE ABOVE CHAMBERS CHECK PLANS FOR PAVEMENT SUBGRADE REQUIREMENTS. 3. 357, 4, 467, COMPACT IN 6' UFTS TO A MINIMUM 95X FILL MATERIAL FOR 6' TO GRANULAR WELL -GRADED SOIL/AGGREGATE 5. 56, 57, 6, 67, A-1 A-2 STANDARD PROCTOR DENSITY. ROLLER GROSS 18" ELEVATION ABOVE CHAMBERS MIXTURES, < 35% FINES. 68, 7. 78, 5. 89, VEHICLE WEIGHT NOT TO EXCEED 12,000 UBS. (24- FOR UNPAVED INSTALLATIONS) 9, 10 A-3 DYNAMIC FORCE NOT TO EXCEED 20,000 LBS. EMBEDMENT STONE SURROUNDING CLEAN ANGULAR STONE NTH THE MAJORITY 3, 357, 4, 457, AND TO A MIN. 6" ELEVATION OF PARTICLES BETWEEN 3/4 - 2 INCH 5. N/A NO COMPACTION REQUIRED. ABOVE CHAMBERS INCH 56, 57 CLEAN ANGULAR STONE NTH THE MAJORITY 3, 35, 4, 467, PLATE COMPACT DR ROLL TO ACHIEVE A 95% FOUNDATION STONE BELOW CHAMBERS OF PARTICLES BETWEEN 3/4 - 2 INCH 5, N/A STANDARD PROCTOR DENSITY. INCH 1 56, 57 1 1 PLEASE NOTE: THE USTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN, ANGULAR. FOR EXAMPLE, THE STONE MUST BE SPECIFIED AS CLEAN, CRUSHED, ANGULAR No. 4 STONE. STORMTECH RECOMMENDS HARDNESS AND DURABIUTY CRITERIA FOR USE OF RECYCLED CONCRETE IN A AND B LOCATIONS. STORM WATER CHAMBERS ACCEPTABLE MATERIALS NO SCALE 5801 Duluth Street Minneapolis, MN 55422 C11111111111111. Ph. 763-546-3434 INSPEC (9) 2015 Consultants: Signature: Issues and revisions: ISSUE LEVEL/ REVISION: DATE: No.: Client: MINNETONKA SCHOOLS WEST MIDDLE SCHOOL Project title: 2016 STORM DRAIN IMPROVEMENTS AND PARKING LOT ADDITION 6421 HAZELTINE BOULEVARD EXCELSIOR, MINNESOTA 55331 Sheet content: STORM CHAMBER DETAILS DATE: 9-1-15 CLIENT PROJECT No.: INSPEC PROJECT No.: BITUMINOUS PAVEMENT DETAIL NO SCALE AS RE( NEW 4" BITUMINOUS PAVEMENT PLACED IN TWO LIFTS NEW 8" COMPACTED CLASS V BASE AGGREGATE EXISTING SUBGRADE SOIL OR BACKFILL TO TO BE GRADED AND COMPACTED ADJUSTING RINGS BACKFILL MATERIAL SHALL AS NEEDED (4" MINIMUM, BE CRUSHED STONE OR 12" MAXIMUM) GRAVEL MATERIAL MEETING STEPS 16" ON PRECAST REINFORCED CONE AND RISER CENTER ON SECTIONS CONFORMING TO ASTM C478. DOWNSTREAM SIDE PROVIDE TOP SLAB WHERE TOTAL BUILD ;KFILL DEPTH DOES NOT ACCOMMODATE CONE SECTION NYLOPLAST JOINTS BETWEEN PRECAST SECTIONS (1) AND CATCH SHALL USE O-RING RUBBER GASKETS \125� NO SCALE CONFORMING TO ASTM C443 w of w NEW NEW PIPE NEW 6" PRECAST CONCRETE PIPE FLOW U) BASE SLAB —EXIST SUBGRADE SOILS AS REQUIRED TO BE COMPACTED CATCH BASIN/MANHOLE DETAIL \L5 .1 NO SCALE LID I C6 d) 0 _J z 2 0 0) 0 CONTROL--\ d—) BLANKET AND SEED < 22 m f 2 C NEW PLANT MEDIUM WITH A WELL BLENDED MIXTURE OF 30% WASHED SAND (AASHTO M-6 OR ASTM C-33),36% PULVERIVED HYPNUM PEAT OR LEAF LITTER COMPOST (MNDOT GRADE 2), AND 35% PULVERIZED TOPSOIL 2LTYP. 1 BACKFILL WITH NEW TOPSOIL AND SEED (MNDOT 25-121 AT 61#/ACRE AT ALL DISTURBED AREAS 1/2" PREFORMED CLOSED CELL ISOLATION JOINT MATERIAL 6"/�2' NO SCALE TOP OF GRADE ELEVATIONS PER GRADING PLAN SEED TO BE MNDOT 25-141 NEW EROSION CONTROL rAT 59# PER ACRE AT BOTTOM BLANKET AND SEED—\ OF CELL ALL OTHER AREAS To BE SEEDED WITH MNDOT 25-121 AT 61# PER ACRE LANDING AREA (4- X 4'MIN.) WITH MAX. SLOPE OF 2% IN ALL NEW ACCESSIBLE PEDESTRIAN CURB DIRECTIONS RAMP CONSISTING 0 61 CEMENT CONCRETE OVER 4" BASE F 7" PORTLAND AGGREGATE NO SCALE INSTALLED ACCORDII� NEW SAFL BAFFLE TO BE % IG To MANUFACTURER'S IN! DNS LID STEPS 16" D.C. NEW CONCRETE WEIR NEW NEW INLET OUTLET PIPE PIPE NEW NON -WOVEN NEW 2" DIA. GEOTEXTILE FABRIC, HOLE THROUGH PROVIDE 12" OVERLAP BASE BOTH SIDES W 8" - 3/4" PLUS x 4,;;* x x x CLEAR LIMESTONE 9 *;A A 16 -0. 's #k . . k .. S. 'a WRAPPEDIN NEW AASHTO M288 CLASS 2 NON -WOVEN GEOTEXTILE FABRIC AS REQUIRED e_ 7 ? NEW MANHOLE #6 DETAIL WITH WEIR AND SAFL BAFFLE NO SCALE TAPERED BACKFILL WITH NEW TOPSOIL AND SEED (MNDOT 26-121 AT 61#1ACRE AT ALL DISTURBED AREAS 12" —BACKFILL WITH NEW TOPSOIL AND SEED (MNDOT 26-121 AT 61#1ACRE AT ALL DISTURBED AREAS 1211 BACKFILL MATERIAL SHALL ......... BE CRUSHED STONE OR .......... GRAVEL MATERIAL MEETING CLASS 1 OR 2 AS SPECIFIED IN ASTM D2321, BACKFILL APACTED MATERIAL SHALL BE PLACED ;KFILL UNIFORMIALLY IN 12" LIFTS AND COMPACTED. NYLOPLAST MANHOLE (1) AND CATCH BASIN DETAIL \125� NO SCALE (SEE GRADING PLAN) LANDING AREA (4- X 4'MIN.) WITH MAX. SLOPE OF 2% IN ALL NEW ACCESSIBLE PEDESTRIAN CURB DIRECTIONS RAMP CONSISTING 0 61 CEMENT CONCRETE OVER 4" BASE F 7" PORTLAND AGGREGATE NO SCALE INSTALLED ACCORDII� NEW SAFL BAFFLE TO BE % IG To MANUFACTURER'S IN! DNS LID STEPS 16" D.C. NEW CONCRETE WEIR NEW NEW INLET OUTLET PIPE PIPE NEW NON -WOVEN NEW 2" DIA. GEOTEXTILE FABRIC, HOLE THROUGH PROVIDE 12" OVERLAP BASE BOTH SIDES W 8" - 3/4" PLUS x 4,;;* x x x CLEAR LIMESTONE 9 *;A A 16 -0. 's #k . . k .. S. 'a WRAPPEDIN NEW AASHTO M288 CLASS 2 NON -WOVEN GEOTEXTILE FABRIC AS REQUIRED e_ 7 ? NEW MANHOLE #6 DETAIL WITH WEIR AND SAFL BAFFLE NO SCALE TAPERED BACKFILL WITH NEW TOPSOIL AND SEED (MNDOT 26-121 AT 61#1ACRE AT ALL DISTURBED AREAS 12" —BACKFILL WITH NEW TOPSOIL AND SEED (MNDOT 26-121 AT 61#1ACRE AT ALL DISTURBED AREAS 1211 SURMOUNTABLE INPUT CONCRETE CURB DETAIL \126� NO SCALE rT_� PIPE BEDDING DETAIL NO SCALE \12-V ADJOINING J WALKWAY (MIN.) 1/2" THICK BITUMINOUSJ PREFORMED JOINTCONCRETE CURB /-PAVEMENT MATERIAL GUTTER /`i�o ACCESSIBLE RAMP ISO. NO SCALE 2V SURMOUNTABLE OUTPUT CONCRETE CURB DETAIL NO SCALE lki_ BACKFILL AND COMPACT 9IRT- ......... IN THE 6"X6" TRENCH AFTER .......... INSERTING STAPLES THROUGH MATERIAL AS AN ALTERNATIVE TO APACTED TRENCHING WHEN TOP OF ;KFILL SLOPE IS RELATIVELY FLAT, EXTEND MATERIAL APPROXIMATELY 40" ON TOP OF THE GROUND AND RANDOMLY STING INSERT STAPLES THROUGH THE �GRADE SOIL MATERIAL APPROXIMATELY 20" APART VIPACTED SAND 4FORMING TO MN/DOT V STORM SEWER BLANKET MATERIAL MUST OVERLAP AT LEAST 6" AND STAPLES INSERTED THROUGH BOTH FABRICS AT A MAXIMUM G TO MEET O.S.H.A. SPACING OF 40" IENTS. ................. ............. m Mai NOW SURMOUNTABLE INPUT CONCRETE CURB DETAIL \126� NO SCALE rT_� PIPE BEDDING DETAIL NO SCALE \12-V ADJOINING J WALKWAY (MIN.) 1/2" THICK BITUMINOUSJ PREFORMED JOINTCONCRETE CURB /-PAVEMENT MATERIAL GUTTER /`i�o ACCESSIBLE RAMP ISO. NO SCALE 2V SURMOUNTABLE OUTPUT CONCRETE CURB DETAIL NO SCALE lki_ BACKFILL AND COMPACT 9IRT- �GRADE IN THE 6"X6" TRENCH AFTER INSERTING STAPLES THROUGH MATERIAL AS AN ALTERNATIVE TO APACTED TRENCHING WHEN TOP OF ;KFILL SLOPE IS RELATIVELY FLAT, EXTEND MATERIAL APPROXIMATELY 40" ON TOP OF THE GROUND AND RANDOMLY STING INSERT STAPLES THROUGH THE �GRADE SOIL MATERIAL APPROXIMATELY 20" APART VIPACTED SAND 4FORMING TO MN/DOT V STORM SEWER BLANKET MATERIAL MUST OVERLAP AT LEAST 6" AND STAPLES INSERTED THROUGH BOTH FABRICS AT A MAXIMUM G TO MEET O.S.H.A. SPACING OF 40" IENTS. TIE THE LAST 6 JOINTS ON INLET PIPE AND BED IN GRANULAR MATERIAL. USE 2 TIE BOLT FASTENERS PER JOINT INSTALLED AT 60 DEG FROM TOP OR BOTTOM OF PIPE. USE 5/8" TIE FOR PIPE SIZES 12" TO 27" SEE DETAIL 6/C2 FOR RIP RAP DETAIL BLANKET MATERIAL MUST— OVERLAP AT LEAST 6" AND STAPLES INSERTED THROUGH BOTH FABRICS AT A MAXIMUM SPACING OF 20" APART NEW BITUMINOUS PAVEMENT NEW PORTLAND CEMENT CONCRETE (DURACRETE OR APPROVED EQUAL) NEW CLASS V BASE AGGREGATE SUBGRADE SOIL TO BE GRADED AND PROPERLY COMPACTED PRIOR TO PLACEMENT OF NEW MATERIALS NOTES, INSERT STAPLES THROUGH THE BLANKET IN A 6"X6" TRENCH WITH EACH PATTERN OF 3 STAPLES APPROX. 20" APART. MAXIMUM STAPLE SPACING. STAPLES MUST BE INSERTED THROUGH OVERLAP MATERIAL, 7 77-// CATEGORY3 EROSION CONTROL BLANKET —AT END OF SLOPE, SECURE BLANKET MATERIAL BY INSERTING STAPLES APPROXIMATELY 20" ml A kll� APART THROUGH THE FABRIC A NOTES: 1. HAND PLACE GRANITE RIPRAP AROUND SIDES AND OVER TOP OF F.E.S. 2. PLACE NONWOVEN GEOTEXTILE FABRIC UNDER RIPRAP AND EXTENDING 1'UNDER F.E.S. 3. INDIVIDUAL STONES SHALL NOT WEIGH LESS THAN 50 POUNDS EACH EXCEPT THOSE USED FOR CHINKING. MIN. BARS BOLTS '12' ill 3/4" 6" 6"MAX. INSTALL 3 HOT DIP GALVANIZED CLIPS TO FASTEN TRASH GUARD TO F.E.S. FLARED END WITH TRASH GUARD NO SCALE MINIMUM 6 C.Y. CLASS Ill GRANITE RIPRAP 2'� PLAN /—RIPRAP OUT FROM THE APRON SHALL NOT BE HIGHER THAN THE APRON INVERT. SECTION A -A ",-NONWOVEN GEOTEXTILE FABRIC EXTEND 1'UNDER FES RIPRAP AT FLARED END DETAIL NU bf.;ALL 5801 Duluth Street Adinneapolls, MN 55422 Ph. 763-546-3434 INSPEC 2015 Consultants: Signature: Issues and revisions: ISSUE LEVEL/ REVISION: DATE: No.: Client: MINNETONKA SCHOOLS WEST MIDDLE SCHOOL Project title: 2016 STORM DRAIN IMPROVEMENTS AND PARKING LOT ADDITION 6421 HAZELTINE BOULEVARD EXCELSIOR, MINNESOTA 56331 Sheet content DETAILS DATE: CLIENT PROJECT No.: INSPEC PROJECT No.: CIS PROJECT MGR: DRAWN BY: BT CHECKED BY: BB Sheet No.: C5 V V "a '40 IC " C�� >. �c -� -�e 10 Nop TIC elir l t Tri I POND OUTLET V CONTROL STRUCTURE lee a WITW TRASH iSUARD k� N (SEE DETAIL 4/5) log. PLARED 141TA TRAV WfNVATI Y� 41 2er CU 'IF -LF -V Onl::i A. 2 . . . . . . . —less-- ---- ------- ------ --26'—W Q4X RC CURB AND &=ER (SEE DETAIL 5/4) NEN CATC14 BASIN. SEE DETAIL 11/4 AND CATCW BASIN NOT USED NOT USED f-RCV1t:>E FLARED END Y41TH TRASW GUARD AND MACE RiF,-RAF, ovER FILTER FABRtC,- (SEE DETAILS 11/4 4 12/4; NEN SUMI= CATCH BASIN, SEE DETAIL 2/5 AND cATcl-i BASIN SCWEDUl INSTALL DRAINTILE BELCH SUBCSRAPE AND DRAIN TO NFN CATCA BASINS. RELOCATED FLACs I -OLE TEMPORART ROCK CONSTRUCTION ENTRANCE SEE DETAIL '214 61TE � GIRAr)[NG FLAN SCALE: I" . W' -O" 11 -- Ft . 21 -- a 'l V�-z RE\/ISEtD: Oroll'310'3 DETAIL SYMBOLS -GENERAL P1 S GENERAL DETAIL NOTES I HEMY CEWIff 'RMT MIS PLAN, SPWFMATl0% ..... OR RUM WAS PREPARED BY W OR UNDM MY 2003 PAVEMENT REHABILITATION 1- shaded portion on key and site plan represent existing buildings, Dhu= AND IHAT I AM A I, verify measurements and conditions on the pro act. Existing/ DULY LMSIoN V 4NSPEC, INC. 2, S ations Include brief descriptions of exisiling conditiom Existing/ LAWS OF THE he SOTAL -Q 3 R Now soil Now concrete MINNETONKA MIDDLE SCHOOL WEST 6801 Duknh Sireet 'q ifications for instructions not shown on drawings. Minneapolis. M14 55422 (763) 546-3434 new materials common &GINA'D. ---- - ------ 4. Ino to several details may be noted Existing/Now MINN P Existing 'I (C)2002 on only ETONKA PUBLIC SCHOOLS a shaded portions on details relpresent existing conditions. base liggragnte 6. Review project specifications for additional details not shown on PROA MGR I -IR DR. BT TYPED OR PRWM NAME� --ATAHLE1,1111- (D drawings. Existing/New CHANHASSEN, MINNESOTA JPROJ. NO. 2041P.0 CK. SL 7- contractor shall be responsible for maintaining safe working bituminous pavement #- conditions on areas for employees or other persons at the site. TE'6 I _3�Q? RE61WRATHUN No. 2S461 JDATE.- SCANNED IN z Z! EXIST. STORMWATER AREAS AREA # PERVIOUS IMPERVIOUS # OF ACRES AREA 1 5.778 .689 6.467 AREA 2 .256 .558 .814 AREA 3 4.097 2.243 6.340 AREA 4 1.390 1.415 2.805 AREA 5 2.747 .234 2.981 AREA 6 1.839 3.872 5.711 AREA 7 3.298 1.552 4.850 AREA 8 1.988 - 1.988 AREA 9 .121 .010 .131 AREA 10 .760 .033 .793 TOTAL 22.274 10.606 32.880 105 Z* I PERMANENT ROADWAY EASEMENT 0 MEL OD Y HiLL BA�DWELL ACP�ES GOLMENHOFF -/ 0- OLMENABIDN. &D Y HiL-L J� 2" 0 GA VE PUBLIC RIGHT STREET N nUTY MENT 1063. CHAIN L K FENCE: LOT V 15 1 WELL A CONC. BOLLARD/ < MIl"WE NORTH LINE OF THE SOUTH UARTER OF THE ORTHWE x 1062,6 QUARTER SEC 3, TWP. 116, R. 23 1 36 Cp x 1052,7 1 44rww (D A 0 TENNIS COUR- 0 x 1062,3 TENNIS COURTS 0 N r, LINK FENCE\� CIE TAINING WALL f- 30 1052.3 M=1020.0 V-1009.1 x 101.6 10 a%q 1�521 TREE LINE (TYP,) la. CP x IN1.7 x IM1.3 le* h x 1061.5 IST. LAY FIEKDS WATERMAiN DRIVEWAY PER. DOC. 116975 & I , 1�� � DATE: 06/03/14 CLIENT PROJECT No.: IV I 212988 RIVEWAY E EMENT DRAWN BY: BT CHECKED BY: 1313 Sheet No.: SHT 1 OF 1 x 1 1,4 x 1060.7 0 H WOOD RE x 1060.4 EXIST -RIM=1059.29 PLA FIELDS RI 060.16 x 1060.4 A A TENNIS COURTS x 1060,6 z A w I x 1060,9 x 1 2.6 0 106 own 2" 4" 2- 6- 2- 2- m 4m -- :i: i III! D Iilliiiiiliiiiiiilll,- -----THAIN LINK FENI 8.5' TRAIL EASEMENT CONG. BOLLARD� PER DOC. NO. A419434 --t 105� \2�-OVERHEAU WKtS S87'12'20"E 1341.> 24 0� ok SOUTH LINE OF THE 1;111�, EXISTING STORMWATER DRAINAGE AREAS 60 0 60 120 "m I I NORTH SCALE IN FEET a �k P14 5801 Duluth Street Minneapolis, MN 55422 Ph. 763-546-3434 INSPEC 2013 Consultants Signature: Issues and revisions: ISSUE LEVEL I REVISION: DATE: No.: Client: MINNETONKA PUBLIC SCHOOLS ISD - 276 MINNETONKA MIDDLE SCHOOL WEST Project title: 2014 PAVEMENT REHABILITATION AND STORMWATER DRAINAGE IMPROVEMENTS 6421 HAZELTINE BLVD. EXCELSIOR, MIN 55331 Sheet content DATE: 06/03/14 CLIENT PROJECT No.: INSPEC PROJECT No.: 212988 PROJECT MGR: CIB DRAWN BY: BT CHECKED BY: 1313 Sheet No.: SHT 1 OF 1 �f I EXIST. STORMWATER AREAS AREA # PERAOUS IMPERMOLIS # OF ACRES AREA 1 5.778 .689 6.467 AREA 2 .256 .558 .814 AREA 3 4.097 2.243 6.340 AREA 4 1.390 1.415 2.805 AREA 5 2.747 .234 2.981 AREA 6 1.839 3.872 5.711 AREA 7 3.298 1.552 4.850 AREA 8 1.988 - 1.988 AREA 9 .121 .010 .131 AREA 10 .760 .033 .793 TOTAL 22.274 10.606 32.880 FA 0 - 0S PERMANENT ROADWAY EASEMENT rob MEL OD Y HiLL IC 36* Cp 1052.7 _OA 41gow TENNIS COURTS TENNIS COURTS x 1062.3 < 1052.3 11=1020.0 V_1EG 9.1 1052.0 # A a 0 F1 TREE LINE (TYP.), V 30 A CCY Rly, INV�7 21 V'1 1 192' O� 2,� DATE: 06103/14 CLIENT PROJECT No.: INSPEC PROJECT No.: 212988 PROJECT MGR: CB DRAWN BY: BA�DWELL CHECKED BY: GOLMENHOFF 1 Q7 IV69 4� SHT 1 AC�ES 1--' ADDN. L 07D Y -HiLff 03322 GA VE PUBLIC RIGHT STREET N TILITY MENT son Im. CHAIN FENCE LO E RD L A 15 1 I CONC. BOLLARD/ L4" MIAWE I V I z NORTH! LINE OF THE SOUTH A TER OF THE T� T QUAR ER SEC 3, TWP. 116, R. 23 ORTHWE 1105) IC 36* Cp 1052.7 _OA 41gow TENNIS COURTS TENNIS COURTS x 1062.3 < 1052.3 11=1020.0 V_1EG 9.1 1052.0 # A a 0 F1 TREE LINE (TYP.), V 30 A CCY Rly, INV�7 21 V'1 1 192' O� 2,� 1W.12 LINK FEt4 ETA/M N �:ITUMZ�U�S W4'L L \-�OVERHEAD WIRES 4, 41,3 b POOL 18, P 04 DMTJON i�2 �'049 v HIP M>> �zz C C. LARDS BENCHM K 1.96 x 10 1051.6 2 x 1051 - TENNIS COURTS .1051.2 1051.2 1050.8 10 TV 0 9 I le 1% x D61.3 x IN1.5 IST LAY FIEKDS WATERMAIN DRWEWAYI PER. DOC. 16975 & 1 RIVEWAY E EVENT 1 .7 A W1 x "0.4 /EXIST -RIM=1059.29 060.16 PLA FIELDS <k 1060,4 A TENNIS COLRT� x 1060.6 z A A x 1MOA 10 2.6 mum to 12" 14" 12" 12" 14" 2- 6. 2- 2' NA 12-'p�kSTIC 2 -10 .4 104 6�N� V=1049. E A ME - 0 ppp��= 1111111111hom 'm ow 2014 PARKING LOT ADDITIOV, 4*0 N 4.2 AGLIME XCPp 7.0 R1'VZ1'0055 60 SE) < NV=1055.9�W) HAIN LINK FENXI, P PER DOC. NO. A419434 - S OU TH LINE OF THE lNa OF T�E OUT ST QUARTER OF THE N, LR SFO 7, OU � UARTE S EXISTING STORMWATER DRAINAGE AREAS 60 0 60 120 SCALE IN FEET m S87012'20"EI341.24 CATE �t roo.5801 Duluth Street Minneapolis, MN 55422 - Ph. 763-546-3434 INSPEC 2013 Consultants Signature: Issues and revisions: ISSUE LEVEL/ REVISION: DATE: No.: Client: MINNETONKA PUBLIC SCHOOLS ISD - 276 MINNETONKA MIDDLE SCHOOL WEST Project title: 2014 PAVEMENT REHABILITATION AND STORMWATER DRAINAGE IMPROVEMENTS 6421 HAZELTINE BLVD. EXCELSIOR, MN 55331 Sheet Content DATE: 06103/14 CLIENT PROJECT No.: INSPEC PROJECT No.: 212988 PROJECT MGR: CB DRAWN BY: BT CHECKED BY: N) Sheet No.: Q7 IV69 4� SHT 1 OF 1 104B - 1105) 1054.7 2 RD 7�3 RIM= U33 30 RC R INV=1046:3 (R) (VERIFY) 0 0535% x -� �'�Imz'049:1 (VERIFY). 1054,9 W I x 1054.4 M�' 0.7' 11 V 9 11 V 034 4 �) IN - N _1113161�6 R"V- 03 1 �511) \v- �4 H NV -1034.5 S) J-1 94, 9"A' LAY <10- '�s'�RCP C�' 105 6 6 R�, _io -10 4,7 SE 23,7 8 L Y PROX) OVERHANG 2, R---` AAI -.Y N �'='C47 '(,N� '5561 A 12 V, R, A '0 18 5 0 R V', 35 A \V S, (12)1 26-T SC 2 ,20- R M- '�52 C) IT '11-�IC46 6 \" _F Cl� �\L 1W.12 LINK FEt4 ETA/M N �:ITUMZ�U�S W4'L L \-�OVERHEAD WIRES 4, 41,3 b POOL 18, P 04 DMTJON i�2 �'049 v HIP M>> �zz C C. LARDS BENCHM K 1.96 x 10 1051.6 2 x 1051 - TENNIS COURTS .1051.2 1051.2 1050.8 10 TV 0 9 I le 1% x D61.3 x IN1.5 IST LAY FIEKDS WATERMAIN DRWEWAYI PER. DOC. 16975 & 1 RIVEWAY E EVENT 1 .7 A W1 x "0.4 /EXIST -RIM=1059.29 060.16 PLA FIELDS <k 1060,4 A TENNIS COLRT� x 1060.6 z A A x 1MOA 10 2.6 mum to 12" 14" 12" 12" 14" 2- 6. 2- 2' NA 12-'p�kSTIC 2 -10 .4 104 6�N� V=1049. E A ME - 0 ppp��= 1111111111hom 'm ow 2014 PARKING LOT ADDITIOV, 4*0 N 4.2 AGLIME XCPp 7.0 R1'VZ1'0055 60 SE) < NV=1055.9�W) HAIN LINK FENXI, P PER DOC. NO. A419434 - S OU TH LINE OF THE lNa OF T�E OUT ST QUARTER OF THE N, LR SFO 7, OU � UARTE S EXISTING STORMWATER DRAINAGE AREAS 60 0 60 120 SCALE IN FEET m S87012'20"EI341.24 CATE �t roo.5801 Duluth Street Minneapolis, MN 55422 - Ph. 763-546-3434 INSPEC 2013 Consultants Signature: Issues and revisions: ISSUE LEVEL/ REVISION: DATE: No.: Client: MINNETONKA PUBLIC SCHOOLS ISD - 276 MINNETONKA MIDDLE SCHOOL WEST Project title: 2014 PAVEMENT REHABILITATION AND STORMWATER DRAINAGE IMPROVEMENTS 6421 HAZELTINE BLVD. EXCELSIOR, MN 55331 Sheet Content DATE: 06103/14 CLIENT PROJECT No.: INSPEC PROJECT No.: 212988 PROJECT MGR: CB DRAWN BY: BT CHECKED BY: 1313 Sheet No.: SHT 1 OF 1