7030 Lucy Ridge Excavation Plan1006.
1001.8
100:
1o16.5
10154
1004.9
1012.5
1001.6
NO846'59"61.5O1009.41
8147
JOB #31202-1011
FIELD CREW: AK
DRAWN BY: BVR
CHECKED BY: DLS
DATE: 8/15/23
1014.2
o14.7
T00260813
1013.5
1013.5
10142
10
10024
1002.7
x 1012,9
19.3
PROPOS90
19.3
1012.0ho2
x 10049
1011.7
1003.2
1004.0
LOT 3
BLOCK4
REVISIONS
3.
T0067
A005.6 1006
t 1012.0 x
1004.1
ADD ADDITION 3/725 EMW
x1012.6 x 1012.0
2
20.0
1012,4j40O25 20sTOOP 001012. CANF
19
REVISED LANDSCAPE PLLAN 04/0424
GRADING ASBUILT 08/12n4 MNM
x 1012.9
1008.5 ×o
/PAVER WALKWAY
x 1005.2 x 1006.5
x to12.0
1012.1 H10123
EXSTING LO 7030 LUCY RIDGE LANE
1008.006.2
RETAINNG. WALL
Q10.0
1004.3
u 15.5
1006.7 To08
looo 1006.3 .1os
$
'o1006.0
100 100
N63011
10069.0
l
x 1012.1
S8212'52"E 163.23
r1005.1
126.49
x 1012.4
5.5
t006 Q104
o09.6
U HYDRANT
LäCY RIDGE CIRCLE
STORM DRAN
x 1011.9
1012.0
134 WALKWAY 31.2 TO 10123 TON22012TTO120
S CATCH BASIN
ATE VALVE
PORCH SsOREEN 6.
o RON PIPE SET
" IRON PIPE FOUND
101
SANITARY MANHOLE
24.0
GFE
1012.4
10123
23.5
1011
1007.4, 1005.9 1006.9
1006.2
101.8COT
SOan
x 1011.9
x 1011.7 K 1011.5
x 1011.8
x 1011.5
012,0,
L1012.44o
7.Q
To20.0E
x 1011.4
x 1011.2
96.0
1011
1007.6 ×
1007.9
10063x
x 1011.,7
ms GROUND ELEVATION
(u7) PROPOSED ELEVATION
wETAND BUFFER POST
R HAND HOLE
U) UTI¯TY PEDESTAL
E) LECTRIC TRANSFORMER
TELEPHONE PEDESTAL
10129b1.5
TOLZ| 1010.J
25.3o10.8
1011.1
Jo11.4
DENOTES SUMP PUMPO0 SEWER SERMCE EEVATNON
1011.4
14000 25TH AVENUE NORTH, SUITE 120
PLYMOUTH MN 55447 (952) 476-6000 www SATHRE COM
1011.6
1011.2
SURVEY LEGEND
1010.8
CURBT0095
STOP h
1010.6
5 10
SATHRE-BERGQUIST, INC.
x 1010.9
1010.5 x
FP 28147
x 1011.5
LANDSCAPE-
1010.5 1010.2
i0085
oo8.4
EXISITNG TREE
PROPOSED TREE
PROPOSED TREE
eITUMINOUS
cONCRETE
4011.01010.o
CONTOUR PROPOSED
cONTOUR EXSTING
DRAINAGE ARROW
1010
'o1d/a1d1
010
x 1010.7
ROCH
Zegen
'50 R=60.00
.67
L
bO.5
10.
-anage Proposed Hardcover
Lot Are
House Arca
Driveway Area
Stoop Area
Front Walk Area
Sereen Porch Area
Stone Walk Arca
Cone. Patio Arca
Sport Court Arca
Total Area
Coverage = 29.3%
aRaGE LAN
PREPARED FOR
CONCRETE CURg
-SANITARY SEWER
STORM SEWER
WATERMAIN
PROPOSSD SLT FENCE
DRAIN TILE
FENCE
16.257 SE
CERTIFICATE OF SURVEY
GONYEA HOMES
270 S.F.
228 S.F.
$3 S.F.
310 S.F.
S74 SF.
=4,76 SF.
-8SBL BUILDING SETBACK UNE
2.287 SE.
903 S.E.
142 S.F.
Property Description; Lot J, Alock 4, THE BLUTFS AT LAKE LUCY, according to thc
recondcd plat thcreof. Carver County, Minncsota,.
2.
6
8
Address: 70 30 Lucy Ridge LANE. Chanhasscn, Minncsota, 55317
We have shown the location of utilitics on the surveyed propcrty by obscrved cvidence only and by available plans. Plcasc notc that we have not placcd a CGopher Stafe Onc Call for this survcy. There may or may not be urderground utiltics in the mapped arca,
therefore extremc caution must be Cxercisc beforc any cxcavation takes place on or ncar
this sitc, Also, plcasc note that scasonal conditions may inhibit our ability to visibly obscrve all the utilities located on the subject propcrty. Before digging. you are rcquircd by Iaw to notify Gopher State One Call at lcast 48 hours in advance at 65 1/454-0002
The contractor shall determins the cxact location of any and all existing utilitics before
commencing work and is responsible or any and all damages arising out of his failure to
Cxactly locatc and prescrve any and all cxisting utilitics.
Must maintain a minimum 2% slopc gradicrt to accommodatc positive drainage
All set offset irons arc measured to hundredths of a foot ard can be uscd s benchmarks.
The proposed driveway shown is concepual only and docs not purport to show Cxactly
how the driveway shall be built.
A title opinion was not fumished to the suvyor as part of this survcy. Only cascments
pcr the recordcd plat are shown unlcss otherwise denotcd hereon.
Proposcd grades shown adjacent to building foundation refsrs to top of black dirt.
Verify sanitary service invert prior to any concrcte work.
Development Plan Data -LO
Garage Floor Elevation
Top of Foundation Elevation
Lookout Floor Elcation
Basement Floor Ekvation
Proposed Elevations -LO
Proposed Garage Floor Elevation
Proposcd Top of FTundation Elevation
Proposed Lookout Elevation
Proposcd Bascmert Floor Elevation
Asbuilt Elevations
Asbuilt Garage Fleor Elevation
Hardcover -5,500 SF
Lot Area -16,257 SF.
House Area
CWay Ara
Sto Area
Front Walk Arca
Scrcen Porch Area
Stone Walk Area
Conc. Patio Area
Total Area
Coverage= 25.8%
2.287 S.F.
Danicl L. Schmidt, PLS
schmidt@sathre.com
20
903 SF.
142 SF.
270 SF.
228 S.F.
53 S.F.
310 SF.
4,193 S.F.
Dated this 19th day of September , 2023.
10
-10122
|012.5
-|006.8
-1003.S
-1012.4
1012.4
10
-1012.7
1007.2
1004.0
Setbacks
I hercby certify hat this suney, plan, or eport was prepared by mne or
under my direct supervision and that I am a culy Licenscd Land Suveyor
under the laws of the State of Minesota.
Min. Street Setback = 20
Min. Corme-Setback-20
Min. Side Setback =75
SCALE IN FEET
Min. Rear Setback25
DRANAGE ADUTIUIY EASEMENTS ARE ONN
HLRAON rROM RECORDEE PLAT AND
LABELEp As SNN
Minnesota License No. 26147
Seetion 03 -Townshis 1l6 -Range 3
40
X972.5 GRADING ASBUILT ELEVATION