4. Public Works Facility: Approve Plans and Specs
CITY OF
CHANHASSEN
7700 Market Boulevard
PO Box 147
Chanhassen, MN 55317
Administration
Phone: 952.227.1100
Fax: 952.227.1110
Building Inspections
Phone: 952.227.1180
Fax: 952.227.1190
Engineering
Phone: 952.227.1160
Fax: 952.227.1170
Finance
Phone: 952.227.1140
Fax: 952.227.1110
Park & Recreation
Phone: 952.227.1120
Fax: 952.227.1110
Recreation Center
2310 Coulter Boulevard
Phone: 952.227.1400
Fax: 952.227.1404
Planning &
Natural Resources
Phone: 952.227.1130
Fax: 952.227.1110
Public Works
1591 Park Road
Phone: 952.227.1300
Fax: 952.227.1310
Senior Center
Phone: 952.227.1125
Fax: 952.227.1110
Web Site
www.ci.chanhassen.mn.us
4-
-
MEMORANDUM
TO:
Todd Gerhardt, City Manger
,'-"'" 0' '"
." '
1,)
FROM:
Paul Oehme, Director of Public Works/City Engineer
February 23, 2009 OV~'
SUBJECT: Public Works Maintenance Facility Project 08-03: Approve Plans
& Specifications; Authorize Ad for Bids
DATE:
PROPOSED MOTION
"The City Council approves the plans and specifications and authorizes ad for
bids for the Chanhassen Public Works Maintenance Facility Project 08-03."
City Council approval requires a simple majority vote of the City Council
present.
BACKGROUND
On January 6, 2009 the Planning Commission approved the site plan.
On January 26, 2009, the City Council approved the site plan.
DISCUSSION
Staffhas been working with the architect and the construction management teams
to complete final design for the public works facility. The design team has been
meeting regularly with the public works staff to determine what should be
included in the facility, layout of the building, site equipment and supplies.
Attached are the layouts and renderings of the facility.
Staff would like to review the final design with Council and receive feedback
before the project is advertised. Final cost estimates for the facility are being
tabulated and will be available at the Council Meeting.
Bids are proposed to be received Thursday, March 19,2009. In all, 15 bid
categories are planned to be received.
There will be a pre-bid meeting at the project site, 7901 Park Place, on Thursday,
March 5, 2009.
The schedule calls for breaking ground on April 27, 2009 with a substantial
completion of December 31, 2009.
g:\eng\public'L2008 projects\08-03 chanhassen maintenance (pw) facility\bkgd 022309 apprv ps.doc
The City 01 Chanhassen · A growing community with clean lakes, quality schools, a charming downtown, thriving businesses, winding trails, and beautiful parks. A great place to live, work, and play.
Paul Oehme
Public Works Maintenance Facility
February 23, 2009
Page 2
Bids
The City will be advertising for 15 bid packages using the construction management approach.
The bid packages are:
Building Concrete
Precast Structural Concrete Walls
Precast Plank
Masonry
Structural Steel/Joists/Decking/Misc. Steel
Structural Stee1/Joists/Decking/Misc. Steel
Carpentry/Finish Carpentry /Millwork/
Doors, Frames, HardwareIMiscellaneous
Specialties Labor and materials
Roofing/Sheetmetal/ Accessories
Aluminum Entrances/Storefronts
Gypsum Board Systems
Painting
Vehicle Maintenance Equipment
Plumbing and Piping Systems
HV AC and Controls Systems
Electrical
Alternate
Labor and Materials
Labor and Materials
Labor and Materials
Labor and Materials
Material Only
Labor Only
Labor and Materials
Labor and Materials
Labor and Materials
Labor and Materials
Labor and Materials
Labor and Materials
Labor and Materials
Labor and Materials
Labor and Materials
The project includes several alternates in the bids that will be used to determine the final scope
of the project depending on how bids come in.
In general, some of the alternates that are intended to be included in the bids are as follows:
1. Deduct for VCT in lieu of ceramic tile at office.
2. Deduct for Modular block retaining walls on the south side of the property in lieu of
recon block walls.
3. Deduct for paint at vehicle storage walls.
4. Deduct for paint at vehicle storage ceiling.
5. Add for concrete bunker dividing walls.
6. Add for Motorized Entry Gate.
7. Add for TPO roofing in lieu of ballasted roofing.
8. Add for six (6) skylights.
9. Add for each additional skylight over six (6) skylights.
10. Deduct for smooth gray concrete precast wall at west side of vehicle storage.
11. Deduct to reduce R-value of the exterior overhead doors to R-9 in lieu ofR-15.68.
12. Deduct to reduce the amount of vision glass at the overhead doors (i.e. the wash bay
door).
13. Deduct to install precast wall in lieu of brick over CMU block at wash bay north wall.
g:\eng\public\_2008 projects\08-03 chanhassen maintenance (pw) facility\bkgd 022309 apprv ps.doc
Paul Oehme
Public Works Maintenance Facility
February 23,2009
Page 3
14. Deduct for sealed concrete in lieu of ceramic tile at the office areas.
15. Deduct for all roofing to be ballasted EPDM in lieu ofTPO.
Quotes
Other smaller work packages will be solicited for quotes. By soliciting for quotes for smaller
items, the City is anticipated to see better pricing and local contractors will have a better
opportunity to receive a contract.
Below is a list of some of the anticipated quotes the staff intends to receive.
. Earthwork - Building
. Earthwork - Site (to be sent at a later date)
. Asphalt Paving (to be sent at a later date)
. Site Concrete (curb and gutter and sidewalk)
. Retaining Walls (all except the concrete retaining walls, they will be included in the
concrete bid package)
. Site Utilities
. Landscaping and Irrigation
. Insulation
. J oint Sealants
. Overhead/Coiling Doors
. Ceramic Tile
. Acoustical Ceilings
. Carpet
. Fuel Island
. Crane
. Appliances
. Furnishings (window coverings)
. Fire Protection
Staff intends to briefly review the proposed project with Council, the costs, bidding approach and
schedule at the Council meeting.
Attachments: Floor Plan
SitelUtility Plan
Renderings
CIP Pages
g:\eng\public'-2008 projects\08-03 chanhassen maintenance (pw) facility\bkgd 022309 apprv ps.doc
I
I
~
~
!
8
fi
i
i
o
,
HORIZONTAL
SCALE IN
I
~
a
~
1
!!
u
..~
:;~
~.
WAlEB...fILL.
SIAIllIi
.~ .:;; :.,,;
.:....:.;...:. "
...... <ti:.....
',. .:....:.,
El!EL.
IUHIl.
~~.~.a.:: :.:.
.....:', . .: ~
~ '.~' ;. ',."
.,'... .
;: ',' .~.: .~
60
,
ffJ
FEET
12" BOX
WASI::\.
DAY
WELIllWZ.
DAY
12" BOX
o 12" BOX
o
13" BOX 0 0 13"BOX
13" BOX
----,-----r----T----,-- -r-60-1
'"
...
o.
t
MAINTENANCE
AREA
Slllti
5Illlf.
VEHICLE
STORAGE
AREA
FFE = 930
304.0'
13" BOX
30. OAK 0
o
16" BOX
o 14"BOX 0
o 16"BOX
G]
13"BOX 0
14" BOX
121
~
AREA
13" 'P 0
4' RETAINING WALL
IS" pop
*
o
d
~
13"POP @
15 axO
-=\ ~ ~
.~.
o IS" BOX
~O
12"MAP 00 0
12" BOX
12" BOX 0
IS"BOX
LEGEND
EXISTING
BOUNDARY UNE
LOT UNE
CENlERUNE
EASEMENT UNE
CURB &: GUTTER
OVERHEAD CABLE TV -OlV-
UNDERGROUND CABLE 1V -UlV-
OVERHEAD ELECTRIC - DE -
UNDERGROUND ELEClRlC - UE -
UGHT POLE i:>
POWER POLE -e-
UNDEOGROUND GAS - UG-
UNDEDGROUND FIBER OPnc - FO -
OVERHEAD TELEPHONE - or -
UNDEDGROOND lRPHONE - UT -
SANITARY MANHOlE 0
SANITARY SEWER - c>-
CATCH BASIN .
CATCH BASIN MANHOLE e
STORM MANHOLE 0
FlAREO END <l
STORM SEWER -~-
GATE VAL\lE t><I
FIRE HYDRANT -6-
WATERMAlN -1-
PROPOSED
-0lY-
-UlV-
-CE-
-IIE-
i:>
-e-
-110-
-,.-
-OT-
-UT-
e
-.-
.
e<<.
e
..
-,.-
..
...
-1-
ITEM
A
B
C
D
E
F
COLD STORAGE
DESCRIPllON
TOPSOIL (30'X30'
RIVER ROCK (30'X30')
WATERMAIN BREAKS (30'X40')
SEALCOAT AGG. (30'X30')
CLASS V (30'X30')
SAND 30'X30')
,m,.
*
-"IlL
c ~ ~
.2 "3
~-8:S
'g g ~-8
{}:s- 3
HUI g
0.;
:J
mil ~ ~
"
<
ill
:E:
~ i"
Il <
0
!a~
~Il
c;;..;> 15
4
Z~
w-
(/)::::!
(/)(J
<<tf
:clL.j
Z(/)D..
<~l<:
:Ca::~
(JOD..
lL.3:(5
O(J~
~~
o=>
a..
Z
<
-I
a..
w
I-
C7i
>-
m
Ul
Z
o
u;
5
w
'"
~
<
o
CHECKEO
JS PO
PROJECT'
08-03
SHEET'
2 9
SIllti
SIillE.
VEHICLE
STORAGE
AREA
I
~
[
z
J
i
, .~ -~-"
FFE = 930
BIOROlL
0
0
,..:
==eo- 0> ==eo-
1.5% x 1.5%928 ------
o
,
60
,
HORIZONTAL
SCALE IN
FEET
--
----
----
----
----
- -===--===--
I
6
II
i
f;
~il
..~
iJ
"8
9.30
LEGEND
EXISTING PROPOSED
BOUNDARY UNE - -
lOT UNE -------
CENTERUNE --- ---
EASEMENT UNE -------------- -------
CURB &: GUTTER
MAJOR CONTOUR ---eoo-
MINOR CONTOUR --aO<_
SPOT ELEVA l10N x BOO X800
DRAINAGE ARROW ~
SOIL BORING
SILT FENCE
CATCH BASIN .. .
CATCH BASIN MANHOLE e .Qr.
STORM MANHOLE 0 .
FLAREO END <l <II
STORM SEYoER -..- -..-
DRA1NllLE -01- -DT-
GRADING NOTES
!lEElI.
ABEA.
PROPOSED CONTOURS REPRESENT ANISHED SURFACE
ELEVAllONS. SPOT ELEVAllONS ALONG PROPOSED
CURB DENOTE GUTTER LINE ELEVAllON.
EXISllNG UllLlllES SHOWN ON THESE PLANS ARE
BASED ON RECORD DRAWINGS AND, WHERE POSSIBLE,
MEASUREMENTS TAKEN IN THE AELD. THE INFORMAllON
IS NOT TO BE RELIED ON AS BEING EXACT OR
x 2J.00 COMPLETE. CONTRACTOR SHALL CONTACT THE
APPROPRIATE UllLlTY COMPANIES AT LEAST 48 HOURS
PRIOR TO EXCAVAllON, TO REQUEST EXACT FIELD
LOCAllON OF UllLIllES. THE CONTRACTOR IS
RESPONSIBLE FOR RELOCAllNG ALL EXISllNG UllLlllES
WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS
;JilL SHOWN ON THE PLANS.
CONTRACTOR TO CALL GOPHER STATE ONE CALL
(1-800-252-1166), 48 HOURS PRIOR TO EXCAVAllON
FOR LOCAllONS OF SMALL UllLlllES.
CONTRACTOR REQUIRED TO PROTECT THE TREES TO BE
SAVED. SHOULD ANY PORllON OF THE TREE BRANCHES
REQUIRE REMOVAL TO PERMIT OPERAllON OF THE
CONTRACTOR'S EQUIPMENT, HE/SHE SHALL OBTAIN THE
SERVICES OF A PROFESSIONAL TRIMMING SERVICE TO
TRIM THE TREES. SHOULD THE CONTRACTOR'S
-"iL OPERAllONS RESULT IN THE BREAKING OF ANY LIMBS,
THE BROKEN LIMBS SHOULD BE REMOVED IMMEDIATELY
AND CUTS SHALL BE PROPERLY PROTECTED TO
MINIMIZE ANY LASllNG DAMAGE. NO TREES SHALL BE
REMOVED WITHOUT AUTHORIZAllON BY THE ENGINEER.
COSTS FOR TRIMMING SERVICES SHALL BE CONSIDERED
INCIDENTAL TO THE GRADING CONTRACT.
CONTRACTOR SHALL STRIP, STOCKPILE AND
RE-SPREAD SUffiCIENT TOPSOIL TO PROVIDE A
MINIMUM 4 INCH DEPTH (COMPACTED) TO ALL
-"iL DISTURBED AREAS TO BE SODDED OR SEEDED.
THE FINISHED BUILDING SUBGRADE ELEVAllON SHALL
NOT VARY BY MORE THAN 0.10 FT. ABOVE, OR 0.10
FT. BELOW, THE PROPOSED ELEVAllON. STREET OR
PARKING AREA SUBGRADE ELEVAllON SHALL NOT VARY
BY MORE THAN 0.05 FT. ABOVE, OR 0.10 FT. BELOW,
THE PRESCRIBED ELEVAllON. AREAS TO RECEIVE
TOPSOIL SHALL BE GRADED TO WITHIN 0.30 FT. OF
THE REQUIRED ELEVAllON, UNLESS DIRECTED
OTHERWISE BY THE ENGINEER. TOPSOIL SHALL BE
GRADED TO WITHIN % INCH OF THE SPECIFIED
THICKNESS.
THE CONTRACTOR SHALL COMPLY WITH THE
REQUIREMENTS OF THE MINNESOTA POLLUllON
CONTROL AGENCY - NAllONAL POLLUTANT DISCHARGE
ELlMINAllON SYSTEM (NPDES) PERMIT. CONTRACTOR
SHALL BE REQUIRED TO BE A CO-APPLICANT WITH
THE OWNER. THE CONTRACTOR SHALL COMPLETE THE
REQUIRED INSPECllON REPORTS AND BE RESPONSIBLE
FOR MAINTENANCE OF THE EROSION CONTROL DEVICES.
;JilL
-"iL
;JilL
;JilL
;JilL
C!
'"
-,
-----
---
..........
..........
'-
--.~-......
'.'..........--
c ~ ~
.!:! "3
]-8:5
'u 5 E ~
. 0'"
li~_ 3
1~li d
z
U
::J
:5 ~
::!
ili
:E:
Q).... QlUl ~ I!!
:: ~ E~l! <;J ;i
sa~
~Ii
~~
4
Z
<(
....J
0-
....J
z~ 0
0::
w- I-
(/)::::! Z
(/)0 0
<(<(~ 0
IlJ...:5 Z
Z(/)D.
<(~:.: 0
Io::D:: en
oo~ 0
lJ...3:c; 0::
Ooli?! w
Cl
>-::i Z
I-m <(
(3=>
0- C>
Z
Ci
<(
0::
C>
>-
lD
'"
z
o
in
5
w
'"
~
""
'"
DESIGNED CHECKED
JS PO
PROJECT'
08-03
SHEET'
4 " 9
.
OERTEL
ARCHITECTS
",~/f "i---.....i
I ~y ""--/ ,,/
i i
I \_~
I j STOREFRdfrMil
r~
.......riT.BRG.
"..'21-<
v~'"
i EL VAllES
,
"'-. /"'-. /"'-- /:... ~/"""'/"""'/
I
~ :-~tr
",::""/1J'!.O'lf;.
"
"
"y "
sr.lIRG......
..,,..-0-,,..
I
I
1795 Saint Clair Avenue
Sl Paul, Minnesota 55105
~~~
-EPOXY pAt{T (AT
~y-,."..)
-
~~~ r~~~
PR01ECIllR -P,,",
~TI" -In
,;
,;
,;
" r'
" r'
/' ",4
,; r'
,; r'
,;
,;
,;
,;
,;
,; "
,; r'
,; r'
,; r'
,; r'
"
,;
,;
,;
,;
,;
"
,;
,;
,;
atUHJI< =\
\.
~
SEEAL1EIiIAlESFCR
P,,*lffGAT't'EIIQ.E
"""""
(651)696-5186 Tel
(6S1)696-S1stlPu
IUlletE
STORAGE
0Ii[)
WASH
BAY
[Jjj]
-D
'i'
::
"
"
CHANHASSEN
PUBLIC
WORKS
1/8"-1' 0"
.......;uij.
SRHfROIr(rt!D.LG.
to.~~4~~
I
!
I I ~p~
! ~A
I T"~r;",
to.E1.~'
CHANHASSEN, MN
~
:( ~\~~/- I
n i n T rn 1;l1 !
======================================~==~~============~~..J
~
~
~2Z~~
.sr.IlRG.A
..1>>'-0-"..
MEZZ.
[]![]
IUlletE
~~~!NCE
[]![]
<>
<>
~(B"~~
~1l.OCK
1'~"'"
..........,
......~~..
..........FlL
0.:::'-'
BUU<
DL
[Jjj]
:'ioo-~~
i
Iii
c:-~~~~~~~~~.:.::.:=.~~~~~~~~~~~~~~~~
=====j,~~~~~~~~~~J
======:::1.-
~~
o BUILDING SECTION
@ BUILDING SECTION
1/8"=1'.0"
1/8"-1'-0"
~
.......lI.O.l'OEc.\ST
.. ,20'... '" 1
,I
A.......
o..ut-I01/t'
r-"---~
1
\1/
r--------~
n.~..~~
1
"
.......
8.114'-0"
/'\. F
~
:LY
B.~;~'"
/'\. i
T.~~.,
A.......
<> ""2'-0"
.m~
r:T PL\IfC .1"+1-
\1f\BJ<C_
<>
:.>>rat~'"
/;
1
A.......
"""'12'-0"
\!.._.~
!UIl ~ ..
_AclED..........
~.~OO"~'"
~.~~'"
n.T.~ r::+
I
---------------------------------------------- I
-------------------------------------------~
======::r.....
-,-.....
@ BUILDING SECTION
1/8"-1'-0"
1/8"-1' 0"
@'""\lll~ j j IIII j j IIII j j j j j I j j 1111~
~~
I I I I I I I I I I I 1;1 I
i~
ELcia~,
PU<....
0..121-11"
00-23
i/
MTt 01' ISSUE: FEBRUARY ef, 200cf
~
!
j ! ~
! i ~~~ ~~~~ ~~~~' y~
I I I! I! '" ,::: ~~:: II n
= = = == = = = = == ~ = = = = = =~== = =============~ ~= === = = =~_.._J =========== = = = = == = = == = = ==============~._.._.J = = = = = = = = = = =~._J:=== - - - - === F~
I I I I
r----y@
CMJ TR5
I I I I I
I I
I I
I I I
~EZZ.
1]2[]
JLO
! i i n
Ii ---1
===========~================================
FINAL BUDGET
REVIEW SET
(NOT FOR CONSTRUCTION)
@ BUILDING SECTION
3/32"-1'-0"
I HEREBY CERTIFY THAT THIS
DocuMENT WAS PREPARED
BY ME OR UNDER MY DIRECT
SUPERVISION AND THAT I AM
A out. Y REGISTERED ARCHITECT
IN THE STATE OF MINNESOTA
-~ JEFfREYI,.ClERIn.
~~
,~~
SHEET~
BUILDING
SECTIONS
~~
A4.1
PI.QTTl]I;:~oOWOO't Fl..E1W.IE:A4.~
T.o.~-o"$
..0._
0.W'-4"
~:::t~.
5llJllEIl COUlSE
c>>tOPY
~~:a-o"
~1~$
-. AuAL
=~.I
o ELEVATION
EAST ELEVATION
3/32"-1'-0"
PRECAST WALL PANEL FINISH
!llJ1"-"""", P............... AT
=......1f01ED
o -lAYOOT WAy VNrf PER
FOlAt4<ESDOltOT
AffEcT 0f$IrtG LJ.YOOTat SPECf1C
~J"~,*,"" li1IIll
sIOloniBlll>.....
:="-TlP.
=:::r ::
PAAEL
_lIdO
'i'
'"
sWooTlt '"'" .....
100'-4--T'lP.
@ ELEVATION
PANEL TYPES
T.O. SlAB $
<'>
<i>
<i>
<'>
<i>
<i>
1/4"-1' 0"
FlL.ElW,lE:ol5.~
08-23
MTE Of ISSUl::: FEBRUARY c:f, 200ct
CMJ TRS
JLO
FINAL BUDGET
REVIEW SET
(NOT FOR CONSTRUCTION)
I HEREBY CERTIFY THAT THIS
DOCuMENT WAS PREPARED
BY ME OR UNDER MY DIRECT
SUPERVISION AND THAT I AM
A DULY REGISTERED ARCHITECT
IN THE STATE OF MINNESOTA
EXTERIOR
ELEVATIONS
A3.1
.."
Gfl
25
--~-----
- - - - -/-:~ - - - ~
i
------~;;;-/ ~~~~:~~:~f~;/7~-~:-
'. ~ .' ",-,.+, """'''''d''''~'2
\;~r.. '. i;;~ ~1~;~~"~~:~~ ~'
I:. I,? ,~'~)O ~3"~L~~~~'7~1fff!' j~~GflJ~~~~~4!
, ." ., ~ '" 'L'l_~ "w"~ .Q;>ll COLLECT,
:Jji:~k::=:~_~?J~:". i~~> ,:::
;<t'~~ .. .~~~tDt . .. ... ';;;,; / '~:~ DRY,;
J i Li iY mmmm., m ~',\,r
C:J-j;"iP)(\<;.;r. rF-'
r::;i~"~iFv ::~ F~ .
,./' ~. _', 11 -48. 11 4:eG' "~~_._.w. te. ~ I +.,,?\~
~ ~ lJP.GfI~ '~~.=-O
"/~'nj \,~ ~/' ~:::.~:~~ ....~~
.:c:::-di tf~ ?-t,( ).-<( ~, ~
- 1'7<m r~. _ l f1 . tl '--.fj_:
~<"~"A ,',....
0g~.~QF1' ,.f\" ['-l;;i-" ;{U::
; 2" "'=7,.""..~~;..,."......{'!.~.~/ij~----L1;3j'ftvb F)l)!~:)OSE
" "~1~==3==~Lqr_~~:- '~=<1 . ,
. I ~.._....: rll ~~.df \J);
@:! ~._...,,-.. --.... 1021'
I i[---1 -~-:J..."I,..:Vli.- _j~'(''''!
, .--i '0J '/.. ",. '''} U N - "
P;':;f~:~~ ...)@ "J!~~I F,;;:tl,i~:D'II" ~..,!~:;;
,iEn
,4[UVE ..' ~i F ~ ~I
" ~ jH N
T& H --""J-m'T-' ';.jLr~
}~>__ r~"':.~~'.JC I~G itf7>
....." .---.. JSEE .n',' ,1...' _ ' 'lej>,
:"., 11-- )u; R{ \;\11 '2~' 11 -
.....,,-....J! Ii" ~I'
mMmmw"'---~dD:""~~-J~ .- ~,
!.~
@
I
i
I
I
I
r'I" : i
tf:;P~:
Ltr-- i
L:n
'\IV
~nJ
P lp
efr' ~i
i~:Q..l JO :
en d~
~.J
'-'
JAN.
""~
-",,-
'" ,
'~ l:f
...w..1R
,I-} 1 :~I
m~;~.~I.: .1.
H" 'j-fO :
Li:l i
~
F E' i~l,m,~ I
1!1:"';i:,;JI
-,.;-...-. .........."J
i;" r!jn}<
~~S1't"i~-:'
CONU<[ TI:: STOOP
iN / FROST FTG.
BOLL.ARD ... TVP.
O.H. DOORS
CD ~C~L;,A l/~~~ l'~D~W'ER 8c SYSTEMS PLAN
@) .ALL
.
__.___n
GENERAL NOTES
A. CONDUIT AND WIRE CONNECTIONS ARE NOT SHOWN. PROVIDE CONDUIT AND
WIRE IS REQUIRED FOR THE INDlCAl[D ORCUITRY.
B. DO NOT INSTAll /oN( ElECTRICAl. EQUIPMENT TO INlIRFIRE WITH SERVIONG
fNAC EQUIPMENT.
C. VERIFY EXACT lOCATION OF CElUNG MOUNTED DrnCES WITH ARCIITECTURAI.
REFlICTED mUNG PIAN, FOR WAll MOUNTED DE'I1CES REFER TO
ARCHITECTURAL INlIRIOR ELEVATIONS.
D. VERIFY EXACT lOCATIONS OF All MECHANICAl. EQUIPMENT WITH DMSION 15
PRIOR TO ROUGH-IN.
E. VERIFY EXACT lOCATIONS OF All OWNER PROVIDED BUIWING EQUIPMENT WIIH
THE OWNER PRIOR TO ROUGH-IN.
F. VERIFY EXACT lOCATIONS AND NEllI CONRGURAllONS Of PWGS OF All. OWNER
PROVIDED BUIWING EQUIPMENT WITH THE OWNER PRIOR TO ROUGH-IN.
KEYED NOTES
G PROVIDE A OUPLfX RECEPTACLE FOR THE CORD AND PlUG CONNECTION TO THE
NEW ElECTRIC WAl[R COIllER (EWe). lOCAl[ RECEPTACLE SUCH THAT IT IS IN THE
OPENING IN THE BACKPlAl[ Of THE EWe AND OONCfAlEO. COORDINAl[ EXACT
lOCATION WITH SUPPUER. PROVIDE so CORD IF NECESSARY.
@ PROVIDE A JUNCTION BOX WITH CIRCUIT IS INDICATED FOR CONNECTION TO THE
DMSION 15 CONTROL PANa COORDINAl[ EXACT lOCATIONS WITH DMSION 15.
o PROVED A TELECOMMUNICATIONS GROUND BUS BAR. REFER TO SPECIFICATION
SECTION 16450 FOR REQUIRElIENTS.
@ PROVIDE (3) 3" SLEEVES FROM ACCESSIBLE CBUNG SPACE INTO I.T. ROOM 1116.
. PROVIDE ARE STOPPING IS REQUIRED.
G TRANSIENT PROl[CTION AND 2" CONDUIT FROM GAl[ CONTROllER HOUSING. REFER
TO SITE PIAN FOR CONDUIT REQUIREMENTS.
@ PROVIDE CONNECTION TO AUlOMATIC DOOR OPERATORS AND HANDICAP PUSH PADS.
PROVIDE All REQUIRED CONNECTIONS. VERIFY EXACT REQUIREMENTS WITH SUPPlJER.
o
i'RO'i1DE 3/4" CONDUIT AND WIRING FROM THE DOOR OPERATOR TO THE OPERATOR
CON1ROl DE'I1CES (PUSH BUTTON, ElECTRIC EYE. AND OTHER ACCESSORIES FOR
ANAL CONNECTIONS BY THE DOOR OPERATOR INSTAllER. VERIFY THE EXACT
lOCATION AND INST1UATION REQUIRElIENTS WITH THE SUPPUER pmOR TO
ROUGH-IN.
G PROVIDE A WORW XRA52, 120 VOLT, ElECTmC HAND DRYER. PROVIDE CONNECTIONS
AND RECESSED BACK BOX IS REQUIRED, VERIFY THE EXACT ltOUNI1NG lOCATION
WITH THE ARCHITECT PRIOR TO ROUGH-IN.
@
PROVIDE A L5-2OR, 1WIST lOCK, RECEPTACLE SURFACE MOUNTED TO mUNG AND
CONNECTION TO PANEL IS INDICATED. PROVIDE 120W lADDER RACKING, AROUND lHE
PERIMEIER AND MOUNTED ABOVE THE RACKS AND SECURED TO THE STRUCTURE.
PROVIDE GROUNDING FOR All lADDER RAC~NG AND RACKS THAT ARE INSTAllED AT
THIS TIME. PROVIDE SIX (6) 6" CABlE WATERFAllS AND INSTAll. All AT LOCATIONS
DIRECTED BY OWNER. PROI!J!lE SIX (6) 50" EXTENSION CORDS WITH AIXIBLE S.O.
CORO, 120-5P ON ONE ENO ANO A STANOARO GROUNDED RECEPTACLE ON THE
OTHER FOR THE CONNECTION or POWER STRIPS THAT Will BE MOUNTED IN THE
RACKS.
PROVIDE FLUSH-MOUNTED FUllY ADJUSTABlE FOUR-COMPARTMENT A.OOR BOX
ASSElIBlY, WAlKER IRFB-4 SEmES, OR APPROVED EQUAL. WIIH I" POWER CONDUIT
RUN UNOERA.OOR TO NfAREST WAll ON lHlS A.OOR. lHEN ROUlE UP WAll. TO
CEIUNG SPACE AND OVER TO PANEL OR IS SHOWN OR IS NOTED. AlSO PROVIOE
(2) I"C, LV. CONDUITS (BUSHED) TO NfAREST WAll. AND UP TO ACCESSIBlE
CEIUNG SPACE. PROVIDE DEVlCES/PLAl[S INDICATED.
@ ;~l;,A~~~~}ECH ROOM
@ THIS AREA SHAU. BE CLlSSIAED ClASS I, DMSION 2 TO lB" ABOVE ANISHED
A.OOR: ROUlE CONDUITS OVERHfAD TO DrnCES lOCATED WITHIN THESE MIfJS DR
PROVIDE SEAL -orrs IS REQUIRED. COORDlNAl[ WITH lHE lOCAl AHJ.
@ lOCATION OF INCOMING (5) 4" CONOUrrs FOR SERVICE ENTRANCE OF TELEPHONE.
CABLE, AND CI1Y PROVIDED COM~UNICATIONS CABlES. COORDINATE WITH lOCAl
UTILJ1lES. REFER TO SHEET EI.O.
@
rll..EIWIE:~
.
OERTEL
ARCIllTECTS
1795 SaiDt Clair AVllIIIIll
SLPmd,~SSlOS
(fSJ) 8I-5l1f 'N
(651)-.&111 ..
--
CHANHASSEN
PUBLIC
WORKS
CHANHASSEN, MN
PAULSON 8c CLARK
ENGINEERING. INC.
~~ LrCo~~ JlnMd
Office: (551) 407-6056
Fax: (651) 407m6476
rf- .'
1: 11
0&-23
~~"' ~ FEBRUARY ~, 200<'1
AJT
DSP
FINAL BUDGET
REVIEW SET
(NOT FOR CONSTRUCllON)
I HEREBY CERTIFY THAT THIS
DOCUMENT WAS PREPARED
BY ME OR UNDER MY DIRECT
SUPERVISION AND THAT I AM
A DULY LICENSED PROFrSSIOtW. ENGINEER
IN THE STATE OF MINNESOTA
FEBRUARY ~. 20Qq
R((lIS11t\.TION 237~"
AREA 'A'
POWER & SYSTEMS
PLAN
E2.1
1 r"
L- .. - .. -- _J /' L_ ... //' i I / /l~'~:'~~"-.-i~~,),J~L WP, ! :';:.;
/'/ /; ~4' .//../. '" 24'~ '
!~~ - ~'CRI ~ :--
..----~<~~~E~~!:!:!-~t--
.~I UH '84 )~::u~:i,~~'B \\;.'~~fi 12:r':':1
5 I'l~:---f- (;V0 ~"'~J r _r-C'\ ' X~. 1-1
c,q i~~;",. - --~,;'~~]I 131..
!~()()!v! /1e~Rr~. ~ 21nz~i;~.?-~~=~~~.f~~~. i.
I / [~~~~~~~~, I GFl ji____mm-tft__J ~ GFl CFl ~ I
. ,." - .....' .. l ~n;p---
~~:-:rll
~ _ _ ~-t i n.--.......l...f......1..
~ ~. ...mmmu..-tl
-- .. --r;::::~:::::.:::.r::..:.:.:::.:.::....
IJ .....
:~~
I..! 1
I ~
lJ
--- - [,--
I:
u
II
Ii
ii
ii
::
II
il
q
!:
::
II
U
IJ~r
II
o
.J,
n
I:
U
\1
Ii
1.1
li :e.
'~Gf1
GENERAL NOTES
A. CONDUIT AND WIRE CONNECJlONS ARE NOT SHOWN. PRlMDE CONDUIT AND
WIRE AS REQUIRED FOR lHE INDICATED CIRCUITRY.
B. DO NOT INSTAll Nff ELEClRICAL EQUIPMENT TO INTERFERE WIlli s~aNG
INAC EQUIPMENT.
C. VERIFY EXACT LOCAflDN OF C8UNG MOUNTED DE\1CES WIlli ARCHITECTURAL
REFLECTED C8UNG PLAN. FOR WAll MOUNTED DE\1CES REFER TO
ARCHITECTURAL INTERIOR ElEVAflONS.
D. VERIFY EXACT lOCAnDNS OF All MECHANICAL EQUIPMENT WIlli DMSION 15
PRIOR TO ROUGH-IN.
E. VERiFY EXACT LOCAflDNS OF All OWNER PRO'IID8D BUIWING EQUI'MENT WIlli
lHE OWNER PRIOR TO ROUGH-IN.
F. All ELEcrnJCAL DE\1CES. CONNECflONS, AND BRANCH C1RCUmNG WIlliIN WASH
BAY SIW.l BE SUITABUE FOR WET LOCATlON.
G. VERIFY EXACT LOCAflDNS AND NOO CONRGURAflONS OF PLUGS OF All OWNER
PRlMD8D BUIWING EQUIPMENT WIlli THE OWNER PRIOR TO ROUGH-IN.
H. THIS ENURE AREA SIW.l BE ClASSIRED ClASS 1. DMSION 2 TO lB' ABIM
RNISH8D flOOR: ROUTE CONDUITS OVERHEAD TO DE\1aES LOCATED WITHN
THESE AREAS OR PRlMDE SEAL-()FF'S AS REQUIR8D. COORDINATE WIlli lHE
lOCAL AlII.
-.JJ.
[~rj:1
~
\II ::
I ,
1-' :
i ~I
VEHiCLE
\'1Aii,jT
6120 ,". ,
SF ~~==\~-~t:
'~~j .
:: ~ ':~i..~=-:=._~-..2_;_~.~~__. ~~~G:."J"ILJi ..
. . .~ ,~J~\::::=]YI i,'~rA'C'NG~u_._. .~ :,
b~ ~ ,....n-r]
r ='i~O,. r']"'--'(-'H,!.l2/~rr:;.~'m
"j, 'j' C,,', JIj' il'li " ~~'.
;~:14~~;~F~~~~i:l~~;J~I;J\, i _~:__
.
KEYED NOTES
o ~= ~5J= ~~~ ~~~~~ ~~~O:~Cfl~~ ~J.
CD ~L;,AI/~~~ 1'~o~I"IER 8. SYSTEMS PLAN
f1L.E1WlE:~
o
PROVIDE 3/4' CONDUIT AND WIRING FROM THE DOOR OPERATOR TO lHE OPERATOR
CONTROL DE\1CES (PUSH BUTTON, ELECTRIC EYE. AND OlHER ACCESSORIES FOR
RNAl CONNECflONS BY THE DOOR OPERATOR INSTAlUER. VERIFY lHE EXACT
lOCAOON AND INSTAllAOON REQUIREMENTS WIlli lHE SUPPlIER PRIOR TO
ROUGH-IN.
.
OERTEL
ARCHITECTS
1795 Saint Clair AVCIIIlO
St. Paul, MiImesota 5510S
(fifl)8U1IlS N
(6JI)llIPU1II....
--
CHANHASSEN
PUBLIC
WORKS
CHANHASSEN, MN
PAULSON 8< CLARK
ENGINEERING. INC.
= L;~ ~oa.glo
Office: (65!} 407-6056
Fa>: (651) 40'7-6478
:8
0&-23
~TE 01' ISSUE: FEBRUARY q, 2ooc:l
AJT
DSP
FINAL BUDGET
REVIEW SET
(NOT FOR CONSTRUCllON)
I HEREBY CERTIFY THAT THIS
DOCUMENT WAS PREPARED
BY ME OR UNDER MY DIRECT
SUPERVISION AND THAT I AM
It. DUlY lICENSED PROFESStOtW.. ENGINEER
IN THE STATE OF MINNESOTA
FEBRUARY q. 200Q
REGISlIIATlON 237Q"
AREA 'B'
POWER & SYSTEMS
PLAN
E2.2
~':1
!S
~
;t'..
,I' ~
~",...-
_~'~i t ..- .......,.
... !II'I"
~ '",", .
~
.
fO<,
.,,,
U
.
Ii;
i\. ,.~, t . I'!'
, ......~. ...., ':J
f* ...... ,.11"'... ..
· "" '"'I.l ~.}
,.~
"""~
.
..
~
~
~
i.l J'.
"''''rf'It .. 'l "i
~ ~~~:::~~il
-i
"-, '
t
Capital Improvement Program
City of Chanhassen, MN
Project # EQ-087
Project Name Public Works Facility Equipment
Account # 1
Account #2
Account # 3
2009 thru 2013 Contact Paul Oehme
Department Major Equipment
Type Equipment
Useful Life
Category Public Works
Priority n/a
Total Project Cost $500,000
Description
Provides the eqiupment for the Public Works facility. This equipment includes the vehicle lifts, computer system, fiber optic connection, security',
. system, fuel system and office equipment. .
Justification
Necessary for the operation of the Public Works facility.
Expenditures
Equipment
Total
Funding Sources
Capital Replacement Fund
Total
Operational Impact/Other
2009
500,000
500,000
2009
500,000
500,000
2010
2011
2012
2013
Total
500,000
500,000
2010
2011
2012
2013
Total
500,000
500,000
42
I
Capital Improvement Program
I City of Chanhassen, MN
2009 thru 2013
Contact Paul Oehme
Department Municipal Buildings
Type Improvement
Useful Life Unassigned
Category Street Equipment
Priority n/a
Total Project Cost $8,300,000
Project #
MB-003
I Project Name Public Works Facility Improvements
Account # 1
Account # 3
I
Account #2
Description I
I The existing Public Works facility is over capacity and is in need of major repairs. The City is expected to grow an additional 30% before ultimate
build out. The existing facility is located on a 5 acre site which is already cramped for storage and operation space. The City completed a facility
needs study in 2007 and completed an exhaustive search to try to make an existing warehouse type building work. It was decided to move the
Public Works building because the existing site is too small for expansion and no warehouse type building was economically feasible to remodel.
I
Justification
I
I The Operations and Maintenance Department needs additional space for repairs, meeting facilities, files, locker rooms, storage, supervisory offices
and proper equipment storage. In addition, the current facility does not meet many City building codes.
I
I
Expenditures
Construction
2009
8,300,000
8,300,000
2010
2011
2012
2013
Total
8,300,000
8,300,000
Total
I
I
I
~
~:
I Operational JmpactIOtber .1
; This project may increase operational costs. However, the new facility is plarmed to be very utility efficient compared to the existing facility.
Funding Sources 2009 2010 2011 2012 2013 Total
GO Bonds 7,000,000 7,000,000
Sewer Utility Fund 700,000 700,000
Surface Water Utility Fund 400,000 400,000
Water Utility Fund 200,000 200,000
Total 8,300,000 8,300,000
Ii
1(_::,',
.0.t,.
~';;
I~i
I;
.~':
49