Loading...
1c. Resurfacing Floors in Fire Station 10 CITY OF CgANHASSEN 7700 Market Boulevard PO Box 147 Chanhassen, MN 55317 Administration Phone: 952.227.1100 Fax: 952.227.1110 Building Inspections Phone: 952.227.1180 Fax: 952.227.1190 Engineering Phone: 952.227.1160 Fax: 952.227.1170 MEMORANDUM TO: Todd Gerhardt, City Manager FROM: Richard Rice, Information Systems Coordinator DATE: May 13, 2013 SUBJ: Award of Bid — Fire Station No. 1 Floor Resurfacing PROPOSED MOTION "The City Council approves the low bid from SwedeBro Resurfacing in the amount of $12,880 which includes adding the tool room, vinyl chips, and integral striping as listed on their bid dated May 8, 2013." Approval requires a simple majority vote of the council. BACKGROUND Finance RECOMMENDATION Phone: 952.227.1140 The apparatus bays at Fire Station No. 1 house two engines, two rescue vehicles, Fax: 952.227.1110 a ladder truck and several other utility vehicles. This area is also used for other Phone: special events such as the Lions Pancake Breakfast and the annual Fire Park &Recreation the low bid from SwedeBro Resurfacing in the amount of $12,880, which Phone: 952.227.1120 Department Open House. The apparatus bay floors have become worn and Fax: 952.227.1110 stained as a result of the normal activities for fire response, training and other 7901 Park Place events. The bay floors were last resurfaced in 2002. A floor resurfacing project Recreation Center ATTACHMENTS 2310 Coulter Boulevard for Station 1 was included in the 2013 Capital Improvement Project, project code Phone: 952.227.1400 MB -20. Fax: 952.227.1404 Senior Center RECOMMENDATION Planning & Phone: 952.227.1125 Natural s l Resource Resources Four bids were received for the resurfacing project. Staff recommends accepting Phone: Fax: 952.227.1110 Fax: 952.227.1110 the low bid from SwedeBro Resurfacing in the amount of $12,880, which — TMI Coatings includes the alternates as listed on the bid dated May 8, 2013. Fire Department Public Works duty crews will be utilized to safeguard the equipment while it is parked outside. 7901 Park Place www.ci.chanhassen.mn.us Phone: 952.227.1300 ATTACHMENTS Fax: 952.227.1310 Senior Center 1. CIP Project Document Phone: 952.227.1125 2. Bid Document — SwedeBro Resurfacing Fax: 952.227.1110 3. Bid Document — TMI Coatings Web Site 4. Bid Document — Garage Floor Coatings www.ci.chanhassen.mn.us 5. Bid Document — Minnesota Service Company G: \Fire Dept \Stations \Station 1\2013 05 08 CC Memo - `nation I Floor.docx J_Q, Chanhassen is a Community for Life - Providing for Today and Planning for Tomorrow Capital Improvement Program 2013 t&u 2017 City of Chanhassen, MN Project # MB -020 Project Name Fire Station - Purchases MWntenanceMeforbishment Account #1 400 - 0000-4706 Account #3 Account #2 Account #4 Description This project is for large purchases, maintenance and refurbishment ofthe fire Department Municipal Buildings Contact John Wolff Type Maintenance Useful We Category Fire Priority n/a Total Project Cost $50,000 Justification I The Main Fire Station was originally built in the 19Ws and remodeled in the late 1980's. The West Fire Station was built in the early 1980's. 3oth stations hold various public events during the year (4th of July, Election Voting, Fire Prevention Week , Open House, National Night Out, ;tc.) and these buildings are the face of the Fire Department to the public. The buildings and the contents require periodic replacement, upgrading, naintenance and refurbishment to ensure a positive image of the Fine Department and the City of Chanhassen. Prior Expenditures 5,000 Maintenance Total 45,000 45,000 Total 45,000 45,000 Prior Funding Sources 2013 2014 2015 2016 2017 Total 5,000 Capital Replacement Equipme 45,000 45,000 Total Total 45,000 45,000 should be no operational impact from these improvements. The current maintenance budget will accommodate for this addition. 2013 2014 2015 2016 2017 Total 62 Resurfacing. 1409 159 Ave. NE • Ham Lake, MN 55304 Office: 763-434-9237 www.swedebro.com Fax: 763-434-8999 Customer: City of Chanhassen Date: 5/8/13 7610 Laredo Drive Chanhassen, MN 55317 RE: Fire Station re- coating Description: Resinous Flooring - Degrease and wash existing coating to clean. - Mechanically abrade existing coating with 36 grit discs. Solvent wipe coating with MEK. - Apply GP37445 Chemical Resistant epoxy in a color to be determined and with a broadcast of 40 -60 silica sand mesh for slip resistance. - Apply Top coat of GP4638 Polyurethane Enamel. Sub - Total: $11,480.0 Project bid to be completed in one phase. Floor must be swept clean from debris prior to our arrival. Project will take 3 days to complete. Foot and light traffic may resume after 24 hours after final coat. Large Trucks and Rigs may resume traffic 72 hours after final coat. Options 1 . Add tool room ............................... ............................... ............................add $400.00 2. Add 2 -3 colors of Estes vinyl chips for accent .................. ............................add $400.00 3. Add integral striping using GP3745 Fast Cure in Safety Yellow ......................add $600.00 . Re- mobilization charge to divide into 2 separate projects ..........................add $2,410.00 Cement, acid and stain colors cannot be precise; Total Price $ therefore finished color and texture will vary from Materials to be Invoiced any color charts or samples shown. All existing expansion joints may be re -cut, cracks in base BALANCE DUE substrata may reoccur. To accept this quote: Pay required deposit, then sign and return the original copy of this document to schedule your installation. Please initial any options chosen. Bids and prices are valid for 60 days Contract subject to terms /conditions listed. Unpaid balances after 60 days of completion may be sent to collections. Unpaid balances are assessed a 1.5% (18% APR) finance charge per month after 30 days. A mechanic's lien may be filed on any unpaid balances after 60 days. Buyer's Signature Date THIS CONTRACT SUBJECT TO THE TERMS AND CONDITIONS LISTED BELOW 1. The terms set forth in this agreement are intended as the complete and exclusive statement of the contract and may not be contradicted by evidence of any prior agreement or of a contemporaneous oral agreement. Only a memorandum signed by both parties and their authorized agent may amend this contract. Any changes to this contract may subject Buyer to additional charges. 2. Seller will complete work as expediently as possible once started and begin work within terms agreed to. Seller is not responsible for delays beyond his control. 3. This agreement is the actual order of the items listed above and it is understood that all items are custom made and all work is custom. Deposit is non - refundable. In case of sale of home or business, contract may be terminated upon payment to Seller of a sum equal to one third of the remaining balance. 4. Buyer agrees to and has read the Chemical Stain Disclaimer form (if necessary), and Expectation form. 5. Balance of money is due upon completion of work. If claim for payment is placed in the hands of an attorney for collection, Buyer agrees to pay Seller a reasonable attorney's fee fixed by the court. 6. Except as provided in writing, Seller does not warrant the goods covered by this agreement and no other warranty expressed or implied is made by Seller. Seller is also not responsible for slip resistance chosen by the Buyer. 7. Warranty is void with regard to any part or parts subject to abuse, neglect, or accidental causes including but not limited to: fire, flood, acts of God, and war. 8. Seller is not responsible for sub - surfaces such as concrete during the installation due to the fact the prior conditions of the surfaces cannot be determined. Any problems that occur due to these sub - surfaces can not be warranted. This includes moisture transmission and hydrostatic pressure in concrete. Any defects in sub - surface will not be addressed unless listed above. 9. Seller will make every reasonable effort, in advance, to protect landscaping, walls and all adjacent areas and items from damage; however, Seller cannot warranty these areas against possible damage. It is the responsibility of the Buyer to protect these areas. Pools must be drained during installation. 10. Seller will not assume responsibility of damage caused by non - recommended maintenance procedures. It is agreed that Seller shall not be liable for any defect or damage resulting from installations requested by Buyer that depart from accepted installation methods. If an unauthorized person services the surface, any warranty is automatically voided and Seller assumes no liability or responsibility for damage. 11. In cases where buyer does not own the home or business to which Seller is installing surface, buyer represents that he has permission of owner to install surface and is fully responsible for completion of contract. Condominium owners, homeowners, and business owners responsible to associations or boards represent that they have or will obtain any necessary approvals. 12. Buyer grants Seller permission to photograph the installation and installation site and use such photographs in future sales presentations and advertising. 13. During the project, Seller may substitute better quality and/or more expensive products and/or processes with or without the verbal or written approval of the Buyer. 14. Buyer must notify Seller a minimum of 48 hours (not including weekends) prior to the scheduled start day of any delays or postponement. If Seller is not notified at least 48 hours in advance, additional charges will be added. 15. Any person or company supplying labor or materials for this improvement to your property may file a lien against your property if that person or company is not paid for the contributions. Under Minnesota law, you have the right to pay persons who supplied labor or materials for this improvement directly and deduct this amount from our contract price, or withhold the amounts due them from us until 120 days after completion of the improvement unless we give you a lien waiver signed by persons who supplied any labor or material for the improvement and who gave you timely notice. Ham Lake, MN 55304 763 - 434 -9237 – Fax 763- 434 -8999 www.swedebro.com 1 YEAR LIMITED WARRANTY The warranty covers the following: A. Resurfacing materials will not peel and /or blister and /or delaminate from the original surface. We strictly follow the manufacture's written criteria and specifications on application. B. Cracks and /or peeling and blistering due to cracks, acts of God, defects in the original surface, heaving, hydrostatic pressure (moisture transmission), vandalism, abuse and /or neglect, are not covered. Name of property owner: Address City Products applied Design SwedeBro Signature — State Phone Date 1409 159 Ave NE GENERAL GP3745 POLYMERS® SELF-LEVELING EPDXY FLOORS PART A GP3745 SERIES PART B GP3745BOI STANDARD HARDENER PART B GP3745B02 FAST CURE HARDENER PRODUCT INFORMATION PRODUCT DESCRIPTION GP3745 SELF - LEVELING EPDXY is a 100% solids, two- compo- nent, recoatable epoxy and binder resin. It may be used directly over primed substrates, or as a gloss seal coat over decorative slung and mortar systems. GP3745 Self- Leveling Epoxy is extemely hard wearing, chemical resistant, impact and abrasion resistant. ADVANTAGES • 100% solids / solvent free • Impact and abrasion resistant • Durable, easy to clean • Chemical resistant • No offensive solvent odor during installation • Suitable for use in USDA inspected facilities • Available with an antimicrobial agent • Fast cure hardener available • Tint bases can be tinted using Maxitoner @ 50% tint strength TYPICAL USES GP3745 SELF - LEVELING EPDXY should be used in areas where maintenance of a high performance, aesthetically appealing and chemical resistant epoxy system is required. GP3745 Self- Leveling Epoxy is suited for use in clean rooms, laboratories, workshops, light assembly areas. LIMITATIONS • Slab on grade requires vapor /moisture barrier. • Substrate must be structurally sound, dry and free of bond inhibiting contaminants. • During installation and initial cure cycle substrate and ambient air temperature must be at a minimum of 50 °F (10 °C). Substrate temperature must be least 5 °F ( -15 °C) above the dew point. • Maximum dry surface temperature not to exceed 160 °F (71 °C). • Strictly adhere to published coverage rates. • Apply clear at only 10-15 mils (250 -375 microns) maximum per coat. • Do NOT use fast cure hardener with tint bases. PRODUCT CH ARACTERIS7ICS (CONT'D) Recommended Spreading Rate Der coat: Minimum Maximum et mils (microns): 6.0 (150) 30.0 (750) pov erage sq Td n : 50 1.3 160 4.0 DiXing Schedule 0- 10.0 mils (250 microns) wet. @ 72 (22 ,Standard Hardener To touch: 6-12 hours minimum To recoat: 8 hours minimum 72 hours maximum Foot traffic: 24 hours minimum Heavy traffic: 72 hours minimum Full cure: 7 days If maximum recoat time is exceeded, abrade surface before recoating. Drying time is temperature, humidity, and film thickness dependent. Pot Life: gallon mass 40 minutes Q 72 - F (22 °C) Drying Schedule 0- 10.0 mils (250 microns) wet: @ 72 - F (22 °C) Fast Cure Hardener: To touch: 4 hours To recoat: 8 hours minimum minimum: 72 hours maximum Foot traffic: 10 -12 hours Heavy traffic: 24-48 hours Full cure: 7 days If maximum recoat time is exceeded, abrade surface before recoating. Drying time is temperature, humidity, and film thickness dependent. Pot Life: gallon mass 25 minutes @ 72•F (22 °C) Shelf Life: Part A: 12 months, unopened Part B (Standard): 12 months, unopened Part B (Fast Cure): 18 months, unopened Store indoors at 40 °F (4.5 °C) to 100 °F (38 °C) PERFORMANCE CHARACTERISTICS SURFACE PREPARATION Proper inspection and preparation of the substrate to receive resinous material is critical. Read and follow the "Instructions for Concrete Surface Preparation" (Form G -1) for complete details. PRODUCT CHARACTERISTICS Finish: Gloss Color: Clear, Standard Colors Wide range of colors possible Volume Solids: 100 %, mixed Mix Ratio: 2:1 VOC (EPA Method 24): <100 g/L ; 0.83 Ib /gal, mixed Test Name Test Method Results Abrasion ASTM D4060, 100 mg loss Resistance CS17 wheel, 1000 cycles Adhesion ACI 503R 300 psi concrete failure Flammability •. Self- extinguishing ove concrete Flexural Strength I ASTM D 790 - 12,400 psi Hardness, Shore D ASTM D 2240 80 Impact Resistance MIL- D -3134J Direct, inch pound greater than 160, passes; Reverse, inch pound greater than 80, passes Tensile Strength ASTM D 638 -6,000 psi www.sherwin - williams.com /protective continued on back GENERAL 'OLYMERS® FLOORS GP3745 SELF - LEVELING EPDXY STORAGE I APPLICATION • MATERIAL DELIVERY AND STORAGE Store materials in accordance instructions, with seals and labels intact and legible. Keep resins, hardeners, and solvents separated from each other and away from sources of ignition. 18 months shelf life is expected for products stored between 40 °F (4.5 °C) - 100 °F (38 ° C). • APPLICATION INSTRUCTIONS 1. Premix 3745A (resin) using a low speed drill and Jiffy blade. Mix for one minute and until uniform, exercising caution not to introduce air into the material. 2. Add 2 parts 3745A (resin) to 1 part 3745B (hardener) by volume. Mix with low speed drill and Jiffy blade for three minutes and until uniform. To insure proper system cure and performance, strictly follow mix ratio recommendations. 3. Apply 3745 using a squeegee or trowel and back roll with a 3/8" nap roller at a spread rate of 50-160 square feet per gallon (1.3- 4.0 meters squared per liter) to yield 6-30 mils (150 -750 microns) WFT making sure of uniform coverage. Take care not to puddle materials and insure even coverage. 4. Allow to cure 24 hours minimum before opening to traffic and water exposure. Note: Epoxy materials will appear to be cured and "dry to touch" prior to full chemical cross linking. Allow epoxy to cure 2-3 days prior to exposure to water or other chemicals for best performance. CHEMICAL RES/smym For comprehensive chemical resistance information, consult the Chemical Resistant Guide and contact the Technical Service Department. CLEANUP Clean up mixing and application equipment immediately after use. Use toluene or xylene. Observe all fire and health precautions when handling or storing solvents. SAFETY Refer to the MSDS sheet before use. Published technical data and instructions are subject to change without notice. Contact your Sherwin - Williams representative for additional technical data and instructions. MAINTENANCE Occasional inspection of the installed material and spot repair can prolong system life. For specific information, contact the Technical Service Department. SHIPPING • Destinations East of the Rocky Mountains are shipped F.O.B Cincinnati, Ohio. • Destinations West of the Rocky Mountains are shipped F.O.B Victorville, California. For specific information relating to international shipments, contact your local sales representative. ORDERING INFORMATION Packaging: Part A: 3.3 gallon (12.5L) and 5 gallon (18.9L) containers Part B: 1.67 gallon (6.31 L) and 5 gallon (18.9L) containers Weight: 10.3 ± 0.2 lb/gal; 1.23 Kg /L mixed, may vary by color DISCLAIMER The information and recommendations set forth in this Product Data Sheet are based upon tests conducted by or on behalf of The Sherwin- Wiiliams Company. Such information and recommendations set forth herein are subject to change and pertain to the product offered at the time of publication. Consult your Sherwin - Williams representative to obtain the most recent Product Data Information and Application Bulletin. WARRANTY The Sherwin- Williams Company warrants our products to be free of manufactur- ing defects in accord with applicable Sherwin - Williams quality control procedures. Liability for products proven defective, if any, is limited to replacement of the defec- tive product or the refund of the purchase price paid for the defective product as determined by Sherwin - Williams. NO OTHER WARRANTY OR GUARANTEE OF ANY KIND IS MADE BY SHERWN- WILLIAMS, EXPRESSED OR IMPLIED, STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUDING MER- CHANTABILITY AND FITNESS FORA PARTICULAR PURPOSE. www.sherwin- williams.com /protective GENERAL GP4638 POLYMERS® HS POLYURETHANE FLOORS FLOOR ENAMEL PART A GP4638 SERIES PART B GP4638B01 STANDARD HARDENER PRODUCT INFORMATION PRODUCT DESCRIPTION GP4638 HS POLYURETHANE FLOOR ENAMEL is a low VOC, tough, high - gloss, durable finish used as a stand -alone coating system or an optional topcoat over other General Polymers high -build flooring systems. 4638 HS POLYURETHANE FLOOR ENAMEL is formulated to meet the tight VOC restrictions imposed by many states. It resists UV degradation, certain aggressive chemicals and possesses superior gloss retention. ADVANTA • Outstanding resistance to a wide range of chemical, weather and mechnaical conditions • Excellent wear • High gloss retention • UV (Ultraviolet) light stable • Abrasion and impact resistant • Suitable for use in USDA inspected facilities • Auto service cemters, airport hangars • Skydrol resistant TYPICAL USES GP4638 HS POLYURETHANE FLOOR ENAMEL is designed as a finish coat on flooring systems used in warehouses, commerical facilities, aircraft h a ng ars, automobile dea and pharmaceut f aci li ties. LIMITATIONS • No recoat window -must be sanded between coats • Urethanes are sensitive to environmental conditions. • Slab on grade requires vapor /moisture barrier. • Substrate must be structurally sound and free of bond inhibiting contaminants. • During installation and initial cure cycle, substrate and ambient air temperature must be at a minimum of 60 °F (16 °C) and 90 °F (32 °C) maximum. Substrate temperature must be least 5 °F ( -15 °C) above the dew point (for lower temperature installation contact the Technical Service Department). • When required, adequate ventilation shall be provided and proper clothing and respirators wom. • Do not premix Part B hardener. • Humidity must not exceed 80% • Do not install in open areas during rain. • Strictly adhere to published coverage rates. • This coating though resistant, is not a guarantee against tire staining. Vehicular tires from cars and trucks to tractors and boat trailers are varied and have the potential to leave a stain under certain conditions. Place rubber mats or carpet pieces under the tires to avoid the issue. SURFACE PREPARATION Proper inspection and preparation of the substrate to receive resinous material is critical. Read and follow the "Instructions for Concrete Surface Preparation" (Form G -1) for complete details. PRODUCT CHARACTERISTICS Color: Clear, Standard and Custom Colors Mix Ratio: 2:1 Volume Solids: 71 % ± 2 %, mixed Weight Solids: 90% t 2 %, mixed VOC (EPA Method 24): Unreduced <250g /L mixed; 2.1 lb/gal 72 hours Reduced 10% <340g /L; 2.8 lb/gal Viscosity, mixed: 1,500 cps Flammability: Self- extinguishing over concrete Recommended Spreadina Rate per coat: Minimum Maximum *et mils (microns): 3 (75) 4 (100) �Co verdge sq fugal (rrr 380 (9.7) 570 (14.5) Dryina Schedule 0 4 mils (100 microns) wet: I @ 73 (23 To touch: 2 hours To recoat: See limitations Light foot traffic: 12 hours Heavy traffic: 72 hours Full Cure: 7 days f maximum recoat time is exceeded, abrade surface before recoating. Drying time is temperature, humidity, and film thickness dependent. Pot Life: gallon mass 15-20 minutes @ 73 °F (23 °C) Shelf Life: Part A: 36 months, unopened Part B: 24 months, unopened Store indoors at 50 °F (10 °C) to 90 °F (32 °C) Flash Point: 102•F (39•C), ASTM D 93, mixed Reducer/Clean Ups Reducer R61C30 or R7 25 PERFORMANCE CHARACTERISTICS Test Name Test Method Results www.sher win- williams.com /protective continued on back ASTM D4060, I Abrasion Resistance CS17 wheel, 1000 163 mg loss cycles Adhesion j AC1503R 300 psi concrete failure Gloss F 73 °F /23 °C, 60 Gloss Meter 85 millage units 50 %RH Impact Resistance ASTM D 2794 Direct inch -pound greater than 100, passes Reverse, inch -pound greater than 100, I passes Pencil Hardness ASTM D 3363 2H Resistance to MIL- D -3134J No slip or flow at Elevated Temperature required temperature of 158 °F (70 Slip Resistance, Floors ASTM C 1028 -96, 1 Passes wet and dry 60 minimum static 1 without SharkGrip Coefficient of Additive and dry with Friction ! SharkGrip Additive www.sher win- williams.com /protective continued on back GENERAL GP4638 POLYMERS° HS POLYURETHANE FLOORS FLOOR E NAME L PART A GP4638 SERIES PART B GP4638BOI STANDARD HARDENER PR ODUCT INFORMATION APPLICATION • APPLICATION INSTRUCTIONS Recommended Primers: for concrete: 3504, 3579 (epoxy primers) Recommended Primers: for tile: 5531 Pre - primer with 3504 Epoxy Primer 1. Premix 4638A (resin) using a low speed drill and Jiffy blade. Mix for one minute and until uniform, exercising caution not to introduce air into the material. 2. Add 2 parts 4638A (resin) to 1 part 4638B (hardener) by volume. Mix with low speed drill and Jiffy blade for three minutes and until uniform. To insure proper system cure and performance, strictly follow mix ratio recommendations. 3. Apply 4638 using a 1/4" nap roller at a spread rate of 380- 570 square feet per gallon, evenly, with no puddles making sure of uniform coverage. Take care not to puddle materials and insure even coverage. 4. Allow to cure 12 hours minimum before opening to light foot traffic. ORDERING INFORMATION Packaging: Part A 1 gallon (3.8L) and 5 gallon (18.9L) containers Part B: 1 gallon (3.8L) containers 5 gallons (18.9L) containers Weight: 10.0 ± 0.2 lb/gal; 1.20 Kg /L mixed, may vary by color CHEMICAL RESISTANCE For comprehensive chemical resistance information, consult the Chemical Resistant Guide and contact the Technical Service Department. CLEANUP Clean up mixing and application equipment immediately after use. Use toluene or xylene. Observe all fire and health precau- tions when handling or storing solvents. SAFETY Refer to the MSDS sheet before use. Published technical data and instructions are subject to change without notice. Contact your Sherwin - Williams representative for additional technical data and instructions. MAINTENANCE Occasional inspection of the installed material and spot repair can prolong system life. For specific information, contact the Technical Service Department. SHIPPING • Destinations East of the Rocky Mountains are shipped FO.B Cincinnati, Ohio. • Destinations West of the Rocky Mountains are shipped F.O.B Victorville, California. For specific information relating to international shipments, contact your local sales representative. DISCLAIMER The information and recommendations set forth in this Product Data Sheet are based upon tests conducted by or on behalf of The Sherwin - Williams Company. Such information and recommendations set forth herein are subject to change and pertain to the product offered at the time of publication. Consult your Sherwin - Williams representative to obtain the most recent Product Data Information and Application Bulletin. WARRANTY The Sherwin- Williams Company warrants our products to be free of manufactur- ing defects in accord with applicable Sherwin - Williams quality control procedures. Liability for products proven defective, if any, is limited to replacement of the defect tive product or the refund of the purchase price paid for the defective product as determined by Sherwin - Williams. NO OTHER WARRANTY OR GUARANTEE OF ANY KIND IS MADE BY SHERWIN- WILLIAMS, EXPRESSED OR IMPLIED, STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUDING MER- CHANTABILITY AND FITNESS FORA PARTICULAR PURPOSE. www. sherwin- williams.com/protective Estes' chips for decorative flooring. Color Chart* Clifford Estes Company 40 Vreeland Ave. Totowa, NJ 07512 toll free 800 - 248 -2271 Standard colors 6MM (1/4 in.) blue EC62502 slate EC62507 � 4t mocha EC62516 :z � green EC62514 It. blue EC62503 AMW autumn gray ` EC62506 YA . Z brick EC62509 IF j ••, . steel blue EC62504 ti ' ►` . t � : It. gray EC62505 J buff EC62511 Special colors" 6mm (1/4 in.) . r mint EC62554 brite yellow EC62552 Olive EC62553 black EC62508 red EC62510 terra cotta EC62551 * Packaged in 251b. cartons. ** Special colors may require more lead time. Colors may vary from actual product due to reproduction. ,*.W PROPOSAL � TMI Coatings, Inc. 3291 Terminal Drive, St. Paul, Minnesota 55121 -1610 Phone: 651- 452 -6100 Fax: 651- 452 -0598 Painting & Restoration Contractors City of Chanhassen NOTE This proposal may be withdrawn by us if not Attn: Ed Coppersmith accepted within 30 days. 7700 Market Blvd, P.O. Box 147 Chanhassen, MN 55317 Date: January 25, 2013 Phone 952- 227 -1180 / Fax 952- 227 -1190 Regarding: Protective Flooring E-mail ecormersmith na�i.chanhassen.mn.us Protective Flooring _TW .Coatings is cer i W as a woman owned bma mess, so cvery dolla spent with TMI c omn %Vw ard your diversity spending goals. TMI Coatings, Inc, has visited your facility and proposes the following scope of work to coat the fire station floor: Fire Station Floor: 86' long x 82' wide including rooms, 250 lineal feet of striping and (2) yellow entrances 1. Prior to TMI beginning work, owner to vacate area so TMI has open access. 2. TMI to prepare surfaces as necessary to ensure adhesion of subsequent coats. TMI may vacuum steel shotblast and/or grind with hand -held grinders with vacuum attachments. All debris caused from our work on site to be disposed of in owner provided container. 3. Repair severely cracked and eroded areas by restoring to surrounding plane. 4. Apply TMI CHEM-RESIST flooring system consisting of a 100% solids, low odor epoxy resin with aggregate fillers. CHEM-RESIST is a resin -rich epoxy that is glossy and aesthetically pleasing. CHEM-RESIST has excellent chemical resistance. Finish texture to be slip resistant for safety. 5. TMI to install striping and coat the entrance yellow. YOUR COST INCLUDING LABOR AND MATERIALS INSTALLED ................... $29,990 MWUAT_ DISCOUNT We can offer a 3% discount if work can be completed before March 31, 2013. NOTES 1. Bid is based on one job mobilization/demobilization. 2. Bid is based on weekday work; add $450 for weekend work. TMI Coatings has considerable experience installing floor coatings for industry. We have completed similar work for City of Plymouth, Plymouth, MN; City of Columbia Heights, Columbia Heights, MN; City of Burnsville, Burnsville, MN; and many others. Enclosed are references for your review. Thank you for the opportunity to submit this proposal to you. You can check out our company history and other coating services at our website at www.tmicoatines.com Visit TMI Coatings' blog at www.tmicoatingsblog.net to learn about problems we have solved for customers like you or become a fan of TMI Coatings on Facebook. If you have any questions about our bid; please call me at 651 -452 -6100. If e-mail is an effective communication tool for you, feel free to contact me at ssirekntmicoatines.com any questions or comments regarding this proposal Enc: Bulletin 619, Floor Coating Reference List as:tmip/dunhassm01sn*roh) ACCEPTANCE The undersigned hereby accepts TMI's proposal and authorizes TMI to furnish all materials and labor required to complete the work set forth in the proposal pursuant to the proposal terms and conditions set forth on the reverse side hereof, for which we agree to pay you the amount set forth in the proposal. If the proposal terms and conditions set forth on the reverse side hereof were not provided with transmission of T1VII's proposal by facsimile, mail or email, the undersigned agrees to request a copy of the proposal terms and conditions before signing below. The undersigned agrees to be bound by the proposal terms and conditions set forth on the reverse side hereof regardless of whether the undersigned requested a copy or read them before signing below. Accepted: Date Respectfully, TMI Coatings, Inc. By e AA Steve Sirek, Indusirial Sales Title Title Customer: Sign and return copy. Retain original for your files. SPF #48 REV 06/10 `6%e PROPOSAL kkw TMI Coatings, Inc. 3291 Terminal Drive, St. Paul, Minnesota 55121 -1610 Phone: 651- 452 -6100 Fax: 651 - 452 -0598 Painting & Restoration Contractors City of Chanhassen Attn: Ed Coppersmith 7700 Market Blvd, P.O. Box 147 Chanhassen, MN 55317 Phone 952 -227 -1180 /Fax 952- 227 -1190 E-mail ecoppersm It ci.chanhassen.mn.us Protective Flooring NOTE: This proposal may be withdrawn by us if not accepted within 30 days. Date, January 25, 2013 Regarding: Protective Flooring ,'.FIFIt cgs. is certified as a woman owned business,. so every dollar�ent with. T1vQ coitM%.tgw�rd our -- • - - — . diversity spending goals. TMI Coatings, Inc. has visited your facility and proposes the following scope of work to coat the fire station floor: Fire Station Floor: 86' long x 82' wide including rooms, 250 lineal feet of striping and (2) yellow entrances 1. Prior to TMI beginning work, owner to vacate area so TMI has open access. 2. TMI to prepare surfaces as necessary to ensure adhesion of subsequent coats. TMI may vacuum steel shotblast and/or grind with hand -held grinders with vacuum attachments. All debris caused from our work on site to be disposed of in owner provided container. 3. Repair severely cracked and eroded areas by restoring to surrounding plane., 4. Apply TMI CHEM - RESIST flooring system consisting of a 100% solids, low odor epoxy resin with aggregate fillers. CHEM - RESIST is a resin -rich epoxy that is glossy and aesthetically pleasing. CHEM- RESIST has excellent chemical resistance. Finish texture to be slip resistant for safety. 5. TMI to install striping and coat the entrance yellow. YOUR COST INCLUDING LABOR AND MATERIALS INSTALLED ................... $29,990 WINTERTIME DISCOUNT: We can offer a 3% discount if work can be completed before March 31, 2013. NOTES 1. Bid is based on one job mobilization/demobilization. 2. Bid is based on weekday work; add $450 for weekend work. TMI Coatings has considerable experience: instilling floor coatings for industry. We have completed similar work for City of Plymouth, Plymouth, MN; City of Columbia'Heights, Columbia Heights, MN; City of Burnsville, Burnsville, MN; and many others. Enclosed are references for your review. Thank you for the opportunity to submit this proposal to you. You can check out our company history and other coating services at our website at www.bnicoatings.com Visit TMI Coatings' blog at www.tmicoatingsblog.net to team about problems we have solved for customers like you or become a fan of TMI Coatings on Facebook. If you have any questions about our bid, please call me at 651 -452 -6100. If e-mail is an effective communication tool for you, feel free to contact me at ssirek aQtmicoatiamcom with any questions or comments regarding this proposal. Eric: Bulletin 619, Floor Coating Reference List as:bWchaohasse n0lsms(roh) ACCEPTANCE The undersigned hereby accepts TMI's proposal and authorizes TMI to furnish all materials and labor required to complete the work set forth in the proposal pursuant to the proposal terms and conditions set forth on the reverse side hereof, for which we agree to pay you the amount set forth in the proposal. If the proposal terms and conditions set forth on the reverse side hereof were not provided with transmission of TMI's proposal by facsimile, mail or email, the undersigned agrees to request a copy of the proposal terms and conditions before signing below. The undersigned agrees to be bound by the proposal terms and conditions set forth on the reverse side hereof regardless of whether the undersigned requested a copy or read them before signing below. Accepted: By Title Date Respectfully. TMI Coatings, Inc. J By � ( eF J Steve Sirek, Indit Wid Sales Title Customer: Sign and return copy. Retain original for your files. SPF #48 REV WM _FLOOR COATING REFERENCE LIST TMI COATINGS, INC. 3291 TERMINAL DRIVE ST. PAUL, MN 55121 (651) 452 -6100 CUSTOMER/JOB LOCATION/CONTACM Greathatch 730 24th Avenue SE Minneapolis, MN 55414 Contact: Kurt Carlson or Kim Zelinski 612 -676 - 72101612 -676 -7200 JOB DESCRIPTION Ceiling decks and beams totaling 50,000 sq. ft. were prepared and coated in multiple phases. Also 50,000 sq. ft. of flooring was coated over several mobilizations. TMI CHEHFRESIST epoxy flooring was installed at 118" thick, suitable for industrial use. Customer rated TMI excellent in service. St Michael Albertville Public Schools 11343 50th Street NE Albertville, MN 55301 Contact: Terry Zerwas 763 -497 -6526 Hutchinson Technology 5905 Trenton Lane Plymouth, MN 55442 Contact: Jim Muetzel or Mike Degner 763 - 519 -6241 or 320 - 587 -1897 Star Tribune 425 Portland Avenue South Minneapolis, MN.55488. Contact Greg 612- 673 -7540 L.R. White Co., Inc. W6636. L.B. White Road Onalaska, WI 54650 Contact Monte Wingert 608- 783 -5691 Advantech LTD 1 227 South 21St Street Fort Dodge, IA 50501 Contact: Paul Etherinton 515- 573 -1070 Silgan Containers Mfg_ Corp: 1400 Plover Road Plover, WI 54467 ! Contac: M. Pete Suski 715- 344 -8070 Gerdau Ameristeel 1678 Red Rode Road St Paul, MN. 55119 Contact Dennis Riley 651- 731 -5655 TMI prepared the floors and applied CHEM- RESIST colored quartz flooring at 1/8" thick to the girl's locker rooms and atrium stairs, totaling 3,600 sq. ft. TMI prepared thousands of sq. ft. of floors by vacuum steel shotblasting and hand grinding prior to installation of CHEM - RESIST Novolac flooring. Novolac has superior chemical resistance in industrial environments. Over 4,000 sq. ft. of flooring in the printing plant was prepared and coated with an ESD floor coating to reduce static electricity. Mechanical room floors-were prepared and :coated approximately 15 years - ago. TM CHEM- RESISTepoxyflooring'was installed to over: 9,800 sq. ft. of aisleways and flooring .in vidckis'areas of the facility. Various finished surfaces were Installed to accommodate the plant's different functions. Sealer /dustproofer was applied to over 14,000 sq. ft. of flooring in the warehouse and production areas. Prior to coating the floor, TMI repaired severely cracked and eroded areas so the floor had a uniform finish. Customer wrote, "work was as promised -no surprises.." Floors and stairs were prepared with a vacuum steel shotbiaster and mechanically abraded. Cracks and divots were repaired and floors were coated with TMI CHEM:RESIST at 118" thick. A white perimeter edge was installed. Customer marked excellent in all areas on our report card. Walls, ceiling, floor and equipment were prepared and coated in the furnace hydraulic room. in'order to access the walls and ceiling, TMI installed rigging for this project. Up to 7 were chosen by owner fbr'toe various pipes; valves and motors. CHEM- RESIST, epoxy flooring was installed with aggregate for a non- slip in several areas of the plant. CUSTOMER/LOCATIONICONTACT Thermo Kin 314 West 90 Street Bloomington, MN 55420 -3693 Contact: Mike Weiss or Jim Weninger 952 -887 -2224 or 952- 887 -2', — X B.wnsville Fire ,Department 91:1; West 140 Street Burnsville, MN 55337 Contact: Dan Hove 952- 8954572 Marzettl/Warren Frozen Foods 803 8 Street SW Altoona, IA 50009 Contact: Terry Warren JOB DESCRIPTION Over $5,400 sq. ft. of flooring and aisleways were Prepared by steel shotblasting and repaired prior to coating with TMI CHEM- RESIST epoxy flooring system. Various thicknesses were applied depending on the traffic on that floor area. Aggregate was incorporated for slip resistance for safety. TMI: installed 3,700 sq. ft. of epoxy_ flooring.4fter repairing cracks_ arid joints in the concrete. and cre2ltirig. an: anchor pattern so new flooring would adhere. Trench interior concrete was restored and angle iron rewelded. Aggregate was applied to make the area non -slip. Line striping was added. This job involved mechanically abrading the floor in two bays. We restored cracks and eroded concrete and applied Ucrete HF to the floor at 1/4" thick. Coving was installed at the floor/wall juncture for a uniform look. Emerson Network Power . 299 Johnson Ave SW, Suite 100 Waseca, MN 56093 Contact: Jeff Norell 507- 833 -6515 Jones. Lang LaSalle- 2825 Lone Oak Parkway Eagan, MN 55121 Contact: Todd Doering / Jason Kessler 651 -406 -2285 1651-406-2608 SPX Service Solutions 655 Eisenhower Drive Owatonna, MN 55060 Contact: Josh Klecker / Tom Gearking 507 -455 -7325 1507-455-7009 has completed 10,000 sq. ft. and is under 7,200 sq. ft. more. Two floor areas totaling 2,907 sq. ft. were mechanically prepared and repairs were made prior to coating with TMI CHEM- RESIST epoxy flooring system at approximately 1/8" thick. Customer marked TMI excellent on our report card.. . IForthe Postal Data Center in. Eagan, MN; TMI'abraded floors'. in three areas.pnor to coati ng.with TMI CHEN1= 7. RESIST epoxy flooring. An °orange peel °finish texture was used for ease..in cleaning. Over 7,500 sq. ft. in all was coated. Customer marked TMI all excellent on our. report card and said thank you for the quality work. Floors were mechanically prepared and repaired prior to coating with an epoxy ESD (electro static dissipative) floor coating. 2,300 sq. ft. of flooring was coated. Treasure Island Cash o_ _. Protective flooring was installed in three phases in P.O. Box 75, 5734 Sturgeon Lake Road several kitchen areas. Floors were mechanically Red Wing, MN 55066 prepared and coated with TMI GHEV- RESIST epoxy Contact: Dennis Jensen / Lary Befort flooring system with aggregate lii a `at 1/8' to we - 651-385-28211651-385-2863. thick. Capital Safety USA 3833 SALA Way Red Wing, MN 55066 -5005 Contact Donnie Gilliland / Tom Early 651 - 385 -6257 1651-385-6287 A warehouse floor, totaling 16,548 sq. ft. was mechanically prepared and repaired prior to coating with TMI CHEM-RESIST epoxy flooring at 1/8" thick. Wright - Hennepin Co-op Electric 6800 Electric Drive Rockford, MN 55373 Contact Lance Hovland 763 -477 -3117 More than 50,000 sq. ft. flooring was coated with a thin - film epoxy sealer /dustproofer. The coating resists solvents and allows for easy maintenance in this truck/maintenance garage. Customer is still satisfied 10 years later. Floor11(6 /11) 2 f V sg Concrete, r, Yri etal, .4 a glossy the -like easj�� and p surla ? d'sanitizeID�I , �`Borld'S�ren� OVA- Jaborator sulab Decks hard 1�detergents 'The non- Food R Ti inRlants" ' Above Iesstad�rdt'a+i3. for >_ . porous'surface does,not:support • Bottlrrx, •: ]!8'- oc 125 rq # ck[ a bacterial grOWOi d "FDA and Commer+ cftF ens USDA.approved for use in the Manufacfuring nts CHEMICAL E TAf�(IrE .` food environments, , "Cold Cure' formula av hemical reslst2l „ ^ . ; TMI can also incorporate special cold area apphcaion where evarlabrle upc>r! rnquest aggregate or.steet fillets into: the temperature epoxy, for OR and wear cesls- top edovef50 F and when a su e v 2/07) r Lan 3291 TERMINAL DRIVE— ST. PAUL, MN 55121 - P:6514526100 F: 651 452 0598 TMICOATINGS.COM GarageFloorCoadngofMN.com ' 5100 US Hwy 169 N New Hope, MN 55428 Phone: 763 - 559 -8732 / Fax: 763 - 559 -8070 Chanhassen Fire Department Attn: Chad Olsen 7610 Laredo Dr. Chanhassen, MN 55317 ESTIMATE DATE: APRIL 29, 2013 6 747 Chadol000 @gmail.com GFC REP JOB PAYMENT TERMS Jason Ripley Fire Truck Garage 5o% down payment: 50% upon completion SILVER GOLD DIAMOND PLATINUM SYSTEM: SYSTEM: SYSTEM: SYSTEM: ($1.95 / SF) ($2.25 / SF) ($2.95 / SF) ($3.25 / SF) ONE COAT ONE COAT ONE COAT PRIMER, ONE COAT PRIMER, DESCRIPTION OF WORK TO BE Q PRIMER, ONE PRIMER, ONE FULL CHIP, ONE ONE COLOR COAT, PERFORMED COLOR COAT COLOR COAT, CLEAR COAT FULL BROADCAST NO CLEAR COAT MED — HEAVY (20 -yr Warranty) VINYL CHIP (5 -Yr Warranty) SPREAD VINYL CHIP TWO CLEAR COATS (LIFETIME ONE CLEAR COAT WARRANTY) (10 -Yr Warranty) Apply Coating System of Choice to Door Line 6942 $ 1 3,536.90 $ 15,619.50 $ 20,478.90 $ 22,561.50 Chemical Wash & Diamond Grind Prep 6942 Included Included Included Included Recoat Yellow Lines and Landings - $ 6.00 / LF 237 $ 1,422.00 $ 1,422.00 $ 1,422.00 $ 1,4.22.00 TOTAL: $ 1 4958.90 $ 17,041.50 $ 21,900.90 $ 23,983.50 WARRANTY: I agree to the conditions of the warranty offered with the system selected above. FINANCIAL RESPONSIBILTY: I further agree to pay all finance charges, collection cost, attorney's fees, and any other cost that may be incurred to enforce collection of any amount outstanding. Per my cardholder agreement, I agree to pay any and all credit card fees in accordance with the terms of my cardholder agreement. ACCEPTANCE: The above prices, specifications, and conditions are satisfactory and are hereby accepted, GarageFloorCoatingofMN.com is authorized to complete the contract as specified. I understand that a fifty dollar ($50) surcharge will be accessed for any returned checks. If GarageFloorCoatingofMN.com has not received payment in full after job is complete, a late payment charge of 10% monthly is applied when payment has not been received by the company within 30 days of completion. Contractor's Notice to Owner: (a) Any person or company supplying labor or materials for this improvement to your property may file a lien against your property if that person or company is not paid for the contributions. (b) Under Minnesota law, you have the right to pay persons who supplied labor or materials for this improvement directly and deduct this amount due from us until 120 day after completion of the improvement unless we give you a lien waiver signed by persons who supplied any labor or material from the improvement and who gave you timely notice. By signing this contract, I agree to, and understand the conditions and acceptance described on this contract, warranty £t information forms. SIGNATURE: DA Make all checks payable to: Garage Floor Coating of MN.com THANK YOUFOR YOUR BUSINESS! WEAPPRECIATE IT Tr4 #YMUCH!! 2064 East Center Circle GARAGE FLOOR Plymouth, MN 55441 Phone: 763 - 559 -8732 Fax: 763 -559 -8070 Coating of MN.com Email: info @GFCMN.com www.GarageFloorCoatingofMN.com Information Form Thank you for choosing Garage Floor Coating of MN.com (GFC). In order to ensure that your coating experience is a pleasurable one, we would like to inform you of some aspects of our coating process: Access to Garage: Homeowner is responsible to provide GFC of MN with access to garage or area (access code, open door, keys, door opener, etc). Homeowner is not required to be present during coating process. Due to odor and unforeseeable changes in timetable of crew schedule, making arrangements to be present is discouraged. Removal of Items: Installers do not move or remove any items from the garage or area to be coated. It is the responsibility of the customer to have all items removed from the garage prior to installation. Under certain circumstances, our installers will move a large or bulky item, but only with prior authorization. Floor Style. Color & Size: Customer has reviewed and approves square footage measurements, floor color, and style. Customer also understands that there may be slight variations in colors from the samples provided. Floor Texture: The finished texture of the floor will be rougher than the samples shown or the floor in our warehouse. Samples do not have antislip on them and finished floor will have antislip and will be rough to the touch to prevent falling. Water: Customer is responsible for providing an adequate water source and that the installers may use water in the preparation/cleaning the concrete. In addition, the customer understands that water may splash on baseboards, walls and cabinets. While the installers use caution, we will not be responsible for reasonable damages. Efflorescence or moisture vapor transmission: Coatings will not adhere to concrete if these conditions exist. Moisture related delaminating is not covered under the warranty. Anti -Slip Aggregate: If a customer chooses not to incorporate anti -slip aggregate additive, the floor may be extremely slippery when wet. Customer also understands that the coating may be slippery under certain conditions with or without aggregate additive. Floor will have a noticeable, somewhat rough texture, and will not be completely glossy smooth. Curing Time: Your new coating requires time to cure. Once the coating process is completed, you can usually walk on the floor within 24hours, but must not park your vehicles or move heavy items back into the garage for at least 48 hours. Please refer to specific instructions provided for your project at the time of completion. Large / Heavy Items: Large appliances or other heavy items should never be dragged across the floor. Use a dolly or hand truck to prevent damage to the coating. Grinding / Sanding: During the preparation process it may be necessary to grind or sand the floor, which may create considerable dust. It is the responsibility of the customer to ensure that any dust sensitive items are isolated from the area. Odors: In order to provide the highest quality coating, we may use materials that contain a high odor content. These materials emit odors that may cause temporary discomfort. GFC of NIN makes every effort to minimize the odors from entering the property. If you have any questions, please contact our office. Health Issues By signing this form, you have indicated you have no health issues related to respiratory or sensitivity to smell. GFC is not responsible for any discomfort that may occur during the process or after. If any health issues exist, it is the homeowners responsibility to make GFC aware before the project starts. A health waiver may need to be signed before we can proceed. Damages / Reimbursements: GFC of MN will not issue any reimbursements without prior arrangements. Gas Water Heaters: GFC of MN may use leaf blowers in the cleaning/drying process. While every precaution is taken, it is possible that the blower may extinguish the pilot light. This is not a dangerous situation; however we are aware of the inconvenience this may cause. Please contact us immediately if you are not able to re -light the pilot and we will send someone out to re -light it for you. Water Softener: GFC of MN will coat around the water softener unless homeowner has the softener removed. Garage Cabinets: GFC of MN will not be responsible for pre- existing damages to cabinets. Battery Acid Damages: GFC of MN will not warranty any coating against battery acid damage. Please use caution when filling of charging golf cart, motorcycle, or any other automotive type batteries. Motorcycle Kickstands: Kickstands can scratch your coating. Please use a kickstand pad or take other precautions. Concrete Cracks: Every attempt will be made to disguise cracks in the concrete slab. However, GFC of MN does not guarantee that these cracks will not reappear. Touch Ups / Repairs: If there is ever a need for a touch up or repair, there may be a variation in the coating and chip colors after the repair is complete. Although GFC of MN will make every attempt to blend the colors, the repair may be noticeable. Concrete Edges Every attempt will be made to repair edges but damage may still be visible. These areas are not warranteed. I have read and understand the above information: Signature: Date: 2064 East Center Circle GARAGE FLOOR Plymouth, MN 55441 Phone: 763-559-8732 Fax: 763 -559 -8070 Coating of MN.com Email: info @GFCMN.com Limited Coating Warranty (Warranty does not cover concrete failure below coating) 1. Garage Floor Coating of MN.com guarantees against any surface delamination (peeling) due to product failure for the specified duration of your selected coating system_ Warranty is non - transferable. 2. Garage Floor Coating of MN.com does not guarantee coating against damages caused by customer negligence or abuse. Repairs can be done at an additional hourly cost. 3. Garage Floor Coating of MN.com does not guarantee against staining caused by hot tires, grease, oil, gasoline, transmission fluid, or battery acid. These will cause coating to dull in areas where spill /exposure occurs. Regular cleaning with vinegar and water is required to ensure long life of shine. 4. Garage Floor Coating of MN.com does not guarantee against dulling of finish caused by customer negligence which includes but is not limited to lack of cleaning/general care, heavy use, harsh chemical cleaning, or cleaning with abrasive materials and/or chemicals, or the use of scrubbing / buffing machines. 5. Garage Floor Coating of MN.com does not guarantee against cracking of coating caused by concrete heaving, shifting, popping, settling, or ground movement. Areas can be repaired for an additional charge. 6. Clear Coat is scratch and impact resistant under normal conditions. Clear coat will, however, scratch and /or chip if heavy or sharp objects are dropped onto, or slid / dragged across floor. General care & caution should always be exercised. Scratches and chips can be repaired for an additional charge. 7. Touch / repairs: If there is ever a need for a touch up or repair, there may be a variation in the coating and/or chip colors after the repair is complete. Although Garage Floor Coating of MN.com will make every attempt to blend the colors, the repair may be noticeable. 8. Concrete Cracks: Every attempt will be made to disguise cracks in the concrete slab; however, Garage Floor Coating of MN.com does not guarantee that these cracks will not reappear. 9. Span Crete: While application of the Garage Floor Coating system greatly increases protection from water & moisture intrusion, it is not intended to be a water - proofing solution. Shifting and moving of the Span Crete may occur, and Garage Floor Coating of MN.com does not guarantee against water leakage /intrusion to areas below Span Crete, or to the actual surface coated as a result. 10. Damaged Floors: This coating is only cosmetic in nature. While every attempt will be made to conceal existing damage, some flaws / imperfections may be seen after the final coat. 11. Finish Texture: Due to the uneven nature and variation in the coarseness of concrete at the outset, the final finish and/or texture may vary upon completion. 12. Moisture: Moisture intrusion, hydrostatic pressure, or other moisture related issues are not warranteed, however can be repaired for an additional charge. 13. Stem Walls: Coated stem wall appearance may vary from floor finish; however every attempt will be made toward uniformity. 14. Expansion Joints: Expansion joints and saw cuts will be filled but may still be visible after final clear coat. Expansion joints are seams designed to move and shift with the concrete. Each joint is filled with a flexible polymer filler designed to move and shift along with the concrete. However, in cases of shifting, the coating may crack as it is being stressed by the moving concrete. This is normal and may be expected. 15. Existing Coating_ If Garage Floor Coating is coating over an existing coating, no warranty will be provided as we cannot guarantee the bond of the existing coating to the concrete. 16. Rust Stains: Garage Floor Coating does not warranty against rust stains appearing on coating, either from on top or from within. Any rusty metal items need to have protection between the floor coating and the metal item to ensure against staining. 17. Aprons: Exterior items are exposed to the elements such as weather, ice, heat and may cause concrete to move and shift. Garage Floor Coating of MN.com offers no warranty on any exterior areas. 18. Any exposed edges such as where driveway and coating meet are not under warranty. These areas expand and contract which causes movement in the concrete, and cannot be prevented. 19. Aggregate Pops: Aggregate pops may occur in the concrete when moisture pushes the aggregate up and out of the concrete. These pops are unavoidable when this happens and are not included in our limited warranty. 20. Low Spots / Pooling / Drainage: All coating systems follow the existing contour of the concrete. While every attempt to fill low areas will be made, they may still remain. You may notice water collecting on the surface of your floor as there is no longer a porous surface for water to drain. The coating will not redirect drainage of water, but will protect the concrete from its absorption and consequent deterioration. By signing this contract, I understand, agree to and accept all conditions of the warranty as stated: Signature: Date: 6836 Russell Ave S Richfield MN 55423 Services For: Prep and coat upto 5800 sq' Options for additional 800 sq' Chanhassen Fire Stntinn Flnnr DIRECT ALL INQUIRIES TO: Paul Gustafson 952 - 913 -5198 email: paul @painterpaul.net www.paimerpaul.net www.MnServiceComl2any.com Bid NUMBER I CHFS- 310410 Bid DATE April 10, 2013 DESCRIPTION 1%MQUNT Choice A $16,530.00 Single Apply single color coat of UV resistant industrial coating to entire floor Coat Color: to be similar to current floor Color: safety yellow on ramps Apply single color coat of industrial coating to entire floor & broadcast nonslip Double Apply a second coat - UV resistant industrial coating Coat Color: to be similar to current floor Color: safety yellow on ramps Options Additional rooms /areas at an estimated 800 sq' Rooms: $3,760.00 Repaint yellow lines on floor but leave the tire taping lines to be done in house Lines: $375 Prep: Use Tenant type machine to degrease, scrub and clean floor. Mechanically abrade floor. Clean Included in bid price and solvent wipe entire floor. We will furnish labor and material- in complete accordance with above specifications. Payment to be made as follows 50% down payment and remaining amount on day of work completion All material is guaranteed to be as specified. All work to be completed in a workmanlike manner according to standard practices. Any alteration or deviation from above specifications involving extra costs will be executed only upon written orders, and will become an extra charge over and above the estimate. No additional interior.or exterior work will be completed. ACCEPTANCE OF PROPOSAL -- The above prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payment will be made as outlined above. Date of Acceptance. Signature Note This proposal may be withdrawn by us if not accepted within days. Name