CULTEC Recharger 150XLHD SubmittalFor more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com. © CULTEC, Inc., February 2015 SUB150XLHD 02-15 CULTEC Recharger® 150XLHD Stormwater Chamber Recharger® 150XLHD Bare Chamber Storage Volumes Elevation Incremental Storage Volume Cumulative Storage in. mm ft 3/ft m 3/m ft 3 m3 ft3 m3 18.5 470 0.006 0.001 0.062 0.002 27.193 0.770 18 457 0.010 0.001 0.103 0.003 27.132 0.768 17 432 0.032 0.003 0.328 0.009 27.029 0.765 16 406 0.077 0.007 0.789 0.022 26.701 0.756 15 381 0.102 0.009 1.046 0.030 25.912 0.734 14 356 0.119 0.009 1.220 0.035 24.867 0.704 13 330 0.134 0.011 1.374 0.039 23.647 0.670 12 305 0.146 0.012 1.497 0.042 22.273 0.631 11 279 0.156 0.014 1.599 0.045 20.777 0.588 10 254 0.165 0.015 1.691 0.048 19.178 0.543 9 229 0.172 0.016 1.763 0.050 17.487 0.495 8 203 0.179 0.017 1.835 0.052 15.724 0.445 7 178 0.184 0.017 1.886 0.053 13.889 0.393 6 152 0.188 0.017 1.927 0.055 12.003 0.340 5 127 0.191 0.018 1.958 0.055 10.076 0.285 4 102 0.193 0.018 1.978 0.056 8.118 0.230 3 76 0.195 0.018 1.999 0.057 6.140 0.174 2 51 0.197 0.018 2.019 0.057 4.141 0.117 1 25 0.207 0.019 2.122 0.060 2.122 0.060 Total 2.650 0.246 27.193 0.770 27.193 0.770 Calculations are based on installed chamber length. 1 Calculations are based on installed chamber length.Includes 6" (152 mm) stone above crown of chamber and typical stone surround. Stone void calculated at 40%. The Recharger® 150XLHD is an 18.5" (470 mm) tall, lower profi le chamber and is typically used for instal- lations with depth restrictions or when a larger infi l- trative area is required. The Recharger® 150XLHD has the side portal internal manifold feature. HVLV® FC-24 Feed Connectors are inserted into the side portals to create the internal manifold. Size (L x W x H)11' x 33" x 18.5" 3.35 m x 838 mm x 470 mm Installed Length 10.25' 3.12 m Length Adjustment per Run 0.75' 0.23 m Chamber Storage 2.65 ft3/ft 0.25 m3/m 27.16 ft3/unit 0.77 m3/unit Min. Installed Storage 4.89 ft3/ft 0.45 m3/m 50.17 ft3/unit 1.42 m3/unit Min. Area Required 33.31 ft2 3.09 m2 Min. Center-to-Center Spacing 3.25' 0.99 m Max. Allowable Cover 12' 3.66 m Max. Inlet Opening in End Wall 12" 300 mm Max. Allowable O.D.in Side Portal 10.25" 260 mm Compatible Feed Connector HVLV FC-24 Feed Connector Stone Foundation Depth 6" 12" 18" 152 mm 305 mm 457 mm Chamber and Stone Storage Per Chamber 50.17 ft3 56.83 ft3 63.49 ft3 1.42 m3 1.61 m3 1.80 m3 Min. Effective Depth 2.54'3.04'3.54' 0.77 m 0.93 m 1.08 m Stone Required Per Chamber 2.13 yd3 2.75 yd3 3.36 yd3 1.63 m3 2.10 m3 2.57 m3 Visit www.cultec.com/downloads.html for Product Downloads and CAD details. For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com. © CULTEC, Inc., February 2015 SUB150XLHD 02-15 CULTEC Recharger® 150XLHD Stormwater Chamber Three View Drawing Hidden End ShSSown with side portal trimmed and optional CULTEC HVLV Feed Connector Feed Connector inserted. Model SHHD Model IHD l EHDMode Model IHD dden EndHid Typical Interlock Installation 2 For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com. © CULTEC, Inc., February 2015 SUB150XLHD 02-15 CULTEC Recharger® 150XLHD Stormwater Chamber Plan View Drawing Typical Cross Section for Traffi c Application 3 For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com. © CULTEC, Inc., February 2015 SUB150XLHD 02-15 CULTEC Recharger® 150XLHD Stormwater Chamber CULTEC Recharger®150XLHD Specifi cations 4 GENERALCULTEC Recharger® 150XLHD chambers are designed for underground stormwater management. The chambers may be used for retention, recharging, detention or controlling the fl ow of on-site stormwater runoff. CHAMBER PARAMETERS 1. The chambers shall be manufactured by CULTEC, Inc. of Brookfi eld, CT (203-775-4416 or 1-800-428-5832). 2. The chamber shall be vacuum thermoformed of black polyethylene. 3. The chamber shall be arched in shape. 4. The chamber shall be open-bottomed. 5. The chamber shall be joined using an interlocking overlapping rib method. Connections must be fully shouldered overlapping ribs, having no separate couplings or separate end walls. 6. The nominal chamber dimensions of the CULTEC Recharger® 150XLHD shall be 18.5 inches (470 mm) tall, 33 inches (838mm) wide and 11 feet (3.35 m) long. The installed length of a joined Recharger® 150XLHD shall be 10.25 feet (3.12 m). 7.Maximum inlet opening on the chamber end wall is 12 inches (300 mm). 8. The chamber shall have two side portals to accept CULTEC HVLV® FC-24 Feed Connectors to create an internal manifold. The nominal I.D. dimensions of each side portal shall be 8.5 inches (216 mm) high by 12 inches (304 mm) wide. Maximum allowable O.D. in the side portal is 10.25 inches (260 mm). 9. The nominal chamber dimensions of the CULTEC HVLV® FC-24 Feed Connector shall be 12 inches (305 mm) tall, 16 inches(406 mm) wide and 24.2 inches (615 mm) long. 10. The nominal storage volume of the Recharger® 150XLHD chamber shall be 2.650 ft3 / ft (0.246 m3 / m) - without stone. The nominal storage volume of a single Recharger 150XLRHD Stand Alone unit shall be 29.15 ft3 (0.83 m3) - without stone. The nominal storage volume of a joined Recharger® 150XLIHD Intermediate unit shall be 27.16 ft3 (0.77 m3) - without stone. The nominal storage volume of the length adjustment amount per run shall be 1.99 ft3 (0.18 m3) - without stone. 11. The nominal storage volume of the HVLV® FC-24 Feed Connector shall be 0.913 ft3 / ft (0.085 m3 / m) - without stone. 12. The Recharger® 150XLHD chamber shall have thirty discharge holes bored into the sidewalls of the unit’s core to promote lateral conveyance of water. 13. The Recharger® 150XLHD chamber shall have 20 corrugations. 14. The end wall of the chamber, when present, shall be an integral part of the continuously formed unit. Separate end plates cannot be used with this unit. 15. The Recharger® 150XLRHD Stand Alone unit must be formed as a whole chamber having two fully formed integral end walls and having no separate end plates or separate end walls. 16. The Recharger® 150XLSHD Starter unit must be formed as a whole chamber having one fully formed integral end wall and one partially formed integral end wall with a lower transfer opening of 10 inches (254 mm) high x 20.5 inches (521 mm) wide. 17. The Recharger® 150XLIHD Intermediate unit must be formed as a whole chamber having one fully open end wall and one partially formed integral end wall with a lower transfer opening of 10 inches (254 mm) high x 20.5 inches (521 mm) wide. 18. The Recharger® 150XLEHD End unit must be formed as a whole chamber having one fully formed integral end wall and onefully open end wall and having no separate end plates or end walls. 19. The HVLV® FC-24 Feed Connector must be formed as a whole chamber having two open end walls and having no separate end plates or separate end walls. The unit shall fi t into the side portals of the Recharger®150XLHD and act as cross feed connections. 20. Chambers must have horizontal stiffening fl ex reduction steps between the ribs. 21. Heavy duty units are designated by a colored stripe formed into the part along the length of the chamber. 22. The chamber shall have a raised integral cap at the top of the arch in the center of each unit to be used as an optional in- spection port or clean-out. 23. The units may be trimmed to custom lengths by cutting back to any corrugation on the large rib end. 24. The chamber shall be manufactured in an ISO 9001:2008 certifi ed facility. 25. Maximum allowable cover over the top of the chamber shall be 12' (3.66 m). 26. The chamber shall be designed to withstand traffi c loads when installed according to CULTEC's recommended installation instructions.