Loading...
1b1 Chanhassen Business Center, 4th Addition, Audubon, Approve Final Plat I b, I) .....' CITY 0 F CHANHASSEN P.C. DATE: C.C. DATE: 4-27-98 CASE: 98-3 Subdivision I- z <t u :J a.. a. <( ~ ~ W J- - (f) STAFF REPORT PROPOSAL: Final plat for Chanhassen Business Center 4th Addition LOCATION: Outlot D, Chanhassen Business Center, southwest comer of the intersection of Audubon Road and Lake Drive West APPLICANT: Eden Trace Corporation Suite 2000 14500 Martin Drive Eden Prairie, MN 55344 Richard Matthews Suite 2000 14500 Martin Drive Eden Prairie, MN 55344 PRESENT ZONING: Planned Unit Development, PUD . ACREAGE: 7.5 acres ADJACENT ZONING AND LAND USE: N - lOP, Lake Drive West and Vacant Industrial Lot W - PUD, National Weather Service E - PUD-R, Residential Single Family Subdivision and Audubon Rd. S - PUD-R, Residential Single Family Subdivision and Audubon Rd. WATER AND SEWER: Available to site. . PHYSICAL CHARACTER: The site is devoid of vegetation with the exception of the buffer area along Audubon Road. 2000 LAND USE PLAN: Office/Industrial .. .. .. ... .. .. .. .. .. .. .. .. ... ... ... .. .. .. .. .. .. .. ... ... tyof QASSEN .gMap ~ntial District ~sidentiaI District ttiaI District 1./ Residential District pment District lD District rict .. .. .. ... .. 8800 .. .. ft "00 1 .. '000 .. .. .. 'Ioo uoo '300 '400 '500 '600 "00 "00 "00 10000 10100 10200 10300 10400 10500 10600 10700 Final Plat - Chanhassen Business Center 4th Addition April 27, 1998 Page 2 PROPOSAL/SUMMARY On April 13, 1998, the City Council approved the preliminary plat for Chanhassen Business Center 4th Addition to replat 7.5 acres into 2 lots, with the following conditions: 1. Final plat shall be named Chanhassen Business Center 4th Addition. This condition has been met. 2. The developer shall dedicate to the City a 20-foot wide trail easement over the existing trail adjacent to the Audubon Road and a 20-foot drainage and utility easement over the proposed storm sewer extension to Lot 1. This condition has been partially met. The final plat needs to be revised to add the 20 foot wide drainage and utility easement over the proposed storm sewer to Lot 1. 3. The developer shall enter into an amendment to the development contract for Chanhassen Business Center and provide the City with the necessary security and pay the associated final plat fees. This condition still applies. 4. The developer shall be responsible for extending sewer and water service to the development. Sanitary sewer service shall be extended from Audubon Road for Lot 2 and Lake Drive West for Lot 1. Open cutting of Lake Drive West shall be prohibited. The developer will also be responsible for extending storm sewer service to Lot 1 from Lake Drive West. All utility improvements shall be in accordance with the City's latest edition of Standard Specifications and Detail Plates and/or State Plumbing Codes. This condition has been partially met. All utility improvements shall be constructed in accordance with the city's latest edition of Standard Specifications and Detail Plates and/or state plumbing codes. 5. The developer shall prepare a grading, drainage, and erosion control plan for both lots for review and approval by the City. This condition has been met. A site plan for Lot 1 has been submitted to the city for review and approval. Final Plat - Chanhassen Business Center 4th Addition April 27, 1998 Page 3 6. The applicant shall provide detailed storm sewer calculations and drainage maps for a 10- and 100-year storm event, 24-hour duration for the City Engineer to review and approve prior to final plat approval. This condition has been met. 7. The developer shall apply for and obtain permits from the appropriate regulatory agencies, i.e. Watershed District, and comply with their conditions of approval. This condition is still applicable. 8. No berming or landscaping will be allowed within the right-of-way. This condition is still applicable. 9. The applicant shall report to the City Engineer the location of any draintiles found during construction and relocate or abandoned the draintiles as directed by the City Engineer. This condition is still applicable. 10. If importing or exporting of earthwork material is necessary, a haul route and traffic control plan shall be submitted to the City Engineer for review and approval prior to construction commencing. This condition is still applicable. 11. All areas disturbed as a result of construction activities shall be immediately restored with seed and disc-mulched or wood fiber blanket and sod within two weeks of completion of each activity in accordance with the City's Best Management Practice Handbook. All city boulevards disturbed as a result of construction shall be re-sodded. This condition is still applicable. 12. The proposed Industrial development of 4.84 net developable acres is responsible for a water quantity fee of $21,102. This fee is due payable to the City prior to the City filing the final plat. This condition has been modified to reflect the actual developable acres in the plat which is 7.5 acres. Final Plat - Chanhassen Business Center 4th Addition April 27, 1998 Page 4 13. DEVELOPMENT STANDARDS The development standards will remain the same as previously approved with the PUD. a. Intent The purpose of this zone is to create a PUD light industrial/office park. The use of the PUD zone is to allow for more flexible design standards while creating a higher quality and more sensitive proposal. All utilities are required to be placed underground. Each lot proposed for development shall proceed through site plan review based on the development standards outlined below. b. Permitted Uses The permitted uses in this zone should be limited to light industrial, warehousing, and office as defined below. The uses shall be limited to those as defined herein. If there is a question as to the whether or not a use meets the definition, the City Council shall make that interpretation. 1. Light Industrial. The manufacturing, compounding, processing, assembling, packaging, or testing of goods or equipment or research activities entirely within an enclosed structure, with no outside storage. There shall be negligible impact upon the surrounding environment by noise, vibration, smoke, dust or pollutants. 2. Warehousing. Means the commercial storage of merchandise and personal property. 3. Office. Professional and business office, non-retail activity. c. Setbacks In the PUD standards, there is the requirement for landscape buffering in addition to building and parking setbacks. The landscape buffer on Audubon Road is 50 feet, south of Lake Drive and 100 feet along the southern property line. The PUD zone requires a building to be setback 50 feet from the required landscape buffer and public right-of-ways. There is no minimum requirement for setbacks on interior lot lines. The following setbacks shall apply: B 'ld' P k" U1 mg ar mg Audubon Road Buffer & Setback 50' plus 50' 50' plus 10' South Property Line & Setback 100" plus 50' 1 00' plus 1 0' Front & Rear ROW on Lake Drive 25' IS' Final Plat - Chanhassen Business Center 4th Addition April 27, 1998 Page 5 Interior Side Lot Line 10' 10' Railroad Right of Way 30' 30' Audubon Road south of Lake Drive 100' 100' d. Development Standards Tabulation Box Chanhassen Business Center Fourth Addition (Outlot D) Lot # Lot Size - Acres Building Sq. Ft. Building Impervious Coverage 1 2.66 57,000 29% 60% 2 4.84 44,000 25% 60% Subtotal 7.5 101,000 avg. 27% avg. 60% The PUD standard for hard surface coverage is 70% for office and industrial uses. The proposed development meets this standard with an average of 56% hard surface coverage. Building Square Footage Breakdown Office 20% 120,700 sq. ft. Manufacturing 25% 150,875 sq. ft. Warehouse 54.09% 326,425 sq. ft. Church 0.91% 5,500 sq. ft. Total 100% 603,500 sq. ft. e. Building Materials and Design 1. The PUD requires that the development demonstrate a higher quality of architectural standards and site design. All mechanical equipment shall be screened with material compatible to the building. 2. All materials shall be of high quality and durable. Masonry material shall be used. Color shall be introduced through colored block or panels and not painted block. Final Plat - Chanhassen Business Center 4th Addition April 27, 1998 Page 6 3. Brick may be used and must be approved to assure uniformity. 4. Block shall have a weathered face or be polished, fluted, or broken face. 5. Concrete may be poured in place, tilt-up or pre-cast, and shall be finished in stone, textured or coated. 6. Metal siding will not be approved except as support material to one of the above materials or curtain wall on office components or, as trim or as HV AC screen. 7. All accessory structures shall be designed to be compatible with the primary structure. 8. All roof mounted equipment shall be screened by walls of compatible appearing material. Wood screen fences are prohibited. All exterior process machinery, tanks, etc., are to be fully screened by compatible materials. 9. The use of large unadorned, prestressed concrete panels and concrete block shall be prohibited. Acceptable materials will incorporate textured surfaces, exposed aggregate and/or other patterning. All walls shall be given added architectural interest through building design or appropriate landscaping. 10. Space for recycling shall be provided in the interior of all principal structures for all developments in the Business Center. f. Site Landscaping and Screening 1. All buffer landscaping, including boulevard landscaping, included in Phase I area to be installed when the grading of the phase is completed. This may well result in landscaping being required ahead of individual site plan approvals but we believe the buffer yard and plantings, in particular, need to be established immediately. In addition, to adhere to the higher quality of development as spelled out in the PUD zone, all loading areas shall be screened. Each lot for development shall submit a separate landscaping plan as a part of the site plan review process. 2. All op~n spaces and non-parking lot surfaces shall be landscaped, rockscaped, or covered with plantings and/or lawn material. 3. Storage of material outdoors is prohibited unless it has been approved under site plan review. All approved outdoor storage must be screened with masonry fences and/or landscaping. Final Plat - Chanhassen Business Center 4th Addition April 27, 1998 Page 7 3. The master landscape plan for the CBC PUD shall be the design guide for all of the specific site landscape developments. Each lot must present a landscape plan for approval with the site plan review process. 4. Undulating or angular berms 3' to 4' in height, south of Lake Drive along Audubon Road shall be sodded or seeded at the conclusion of Phase I grading and utility construction. The required buffer landscaping may be installed incrementally, but it shall be required where it is deemed necessary to screen any proposed development. All required boulevard landscaping shall be sodded. 5. Loading areas shall be screened from public right-of-ways. Wing wall may be required where deemed appropriate. g. Signage 1. All freestanding signs be limited to monument signs. The sign shall not exceed eighty (80) square feet in sign display area nor be greater than eight (8) feet in height. The sign treatment is an element of the architecture and thus should reflect with the quality of the development. The signs should be consistent in color, size, and material throughout the development. The applicant should submit a sign package for staff review. 2. Each property shall be allowed one monument sign located near the driveway into the private site. All signs require a separate permit. 3. The signage will have consistency throughout the development. A common theme will be introduced at the development's entrance monument and will be used throughout. 4. Consistency in signage shall relate to color, size, materials, and heights. h. Lighting 1. Lighting for the interior of the business center should be consistent throughout the development. The applicant's proposal is consistent with the lighting standards for the PUD ordinance. The plans do not provide for street lighting. As with previous industrial parks/roadways, the City has required the developer to install street lights throughout the street system. The street lights should be designed consistent with the existing lighting along Audubon Road. 2. A decorative, shoe box fixture (high pressure sodium vapor lamps) with a square ornamental pole shall be used throughout the development area for area lighting. Final Plat - Chanhassen Business Center 4th Addition April 27, 1998 Page 8 3 Lighting equipment similar to what is mounted in the public street right-of-ways shall be used in the private areas. 4. All light fixtures shall be shielded. Light level for site lighting shall be no more than 1/2 candle at the property line. This does not apply to street lighting." The applicant is requesting final plat approval to subdivide Outlot D into two lots. Lot 1 is proposed to have an area of 2.66 acres and Lot 2, an area of 4.84 acres. This subdivision is consistent with the preliminary plat and staff is recommending approval. BACKGROUND On January 13, 1992, the City Council approved the preliminary plat for the Chanhassen Business Center as shown on the attached site plan. The PUD was amended on February 8, 1993 to allow for a church as a permitted use and the final plat for phase I of the project was approved. On April 24, 1995, the Chanhassen Business Center 2nd Addition, subdividing Outlot C into 7 lots, was approved by the City. On September 25, 1995, the City Council approved the replat of Outlot A into 4 lots, Chanhassen Business Center 3rd Addition. The City Council is being asked to approve the replat of Outlot D, Chanhassen Business Center into a 2 lot subdivision. FINAL PLAT FOR CHANHASSEN BUSINESS CENTER 4th ADDITION The preliminary plat for Chanhassen Business Center 4th Addition was approved on April 13, 1998. As part of this application, Outlot D will be replatted into 2 lots. A building is proposed to be constructed on Lot 2, Block 1, Chanhassen Business Center 4th Addition which was approved by the City Council on April 13, 1998. This subdivision is consistent with the preliminary plat and staff is recommending approval with conditions. Approval of the site plan was contingent upon final plat approval ofthe Chanhassen Business Center 4th Addition by the City Council. Chanhassen Business Center 4th Addition Compliance Table: Lot # Lot Size - Acres 1 2.66 2 4.84 Subtotal 7.5 Final Plat - Chanhassen Business Center 41h Addition April 27, 1998 Page 9 The City has an 8-foot wide bituminous trail adjacent to Audubon Road through the proposed subdivision. According to the preliminary plat, there is no trail easement recorded. Staffhas verified that with the County Recorder that a 20-foot wide trail easement has been dedicated to the city over the proposed lots. In conjunction with site improvements for the subdivision, a storm sewer line is proposed to be extended from Lot 2 to the west line of Lot 1. A drainage and utility easement shall be dedicated on the final plat over Lot 2 for this extension. The minimum width shall be 20-feet wide. There is an underlying development contract with Chanhassen Business Center that should be amended to include this new 41h Addition. It is therefore recommended the developer enter into an amended development contract with the City for this phase. GRADING The site was previously graded in conjunction with Chanhassen Business Center 151 Addition. Upon review of the grading plan, it appears building and parking areas will blend into the existing land form. The site will be re-graded to prepare the building pads and parking lot areas. If exporting or importing of earthwork materials is necessary, a haul route and traffic control plan will need to be submitted to the City for review and approval prior to construction commencmg. The site contains an existing earth berm along Audubon Road. The berm will only be disturbed as a result of utility extensions to the project. No other berms are proposed. DRAINAGE In conjunction with Chanhassen Business Center, a comprehensive storm water drainage system was constructed to address runoff from this site. No on-site ponding will be required with this development. The plans propose on utilizing existing stormwater services to convey stormwater runoff from the site into the City's storm drainage system. A storm sewer line will be extended from the northeasterly driveway to Lot 1 for future service. A 20-foot wide drainage and utility easement shall be dedicated on the final plat over this storm sewer line. Staff is aware of an ongoing drainage problem on the Weather Bureau site as a result runoff from this property. The drainage problem will be resolved with development of this property. The developer has submitted detailed storm drainage calculations and a drainage area map for a 10 and 100-year storm event, 24-hour duration for staff review and approval in conjunction with final plat consideration. Final Plat - Chanhassen Business Center 4th Addition April 27, 1998 Page 10 STREETS The project is proposed to be accessed through two new driveway access points off of Lake Drive West. Access from Audubon Road shall be prohibited. There is an existing 6-foot wide concrete sidewalk on the north side of Lake Drive West. All driveway access points on Lake Drive West shall incorporate the City's industrial driveway detail apron (Detail Plate No. 5207). This will also increase the driveway radii onto Lake Drive West. There are existing street lights along Lake Drive West that are not shown on the plans. The developer should verify that the access points will not be in conflict with the street lights. The applicant shall be responsible for any relocation of street lights in conjunction with site improvements. The conditions of approval for Chanhassen Business Center addresses future traffic signals at the intersection of Trunk Highway 5 and Audubon Road. At that time, staff believed that the installation of signals would be necessary in the next few years and a condition that the developer shall be responsible for a share of the local cost participation of this signal on a percentage basis, based upon traffic generation and full development of this site in relation to the total traffic volume on Audubon Road. In addition, staff required security to guarantee payment of the developer's share of the traffic signal for Phases I, II, and III. It should be worked between the parties whose responsibility it will be to provide the security escrow for the developer's share of the traffic signal of this phase. The City currently has escrow in the amount of$5,000 from the developer ofChanhassen Business Center (Dirlam/Betty O'Shaughnessy) for this traffic signal. At this point, staff will not require any additional escrow for the traffic as long as the $5,000 escrow is maintained. A traffic signal is proposed to be installed in conjunction with the Trunk Highway 5 upgrade proposed in the 2000-2002. UTILITIES Municipal utility service is available from Lake Drive West and Audubon Road. The plans propose on extending sanitary sewer and water service from Audubon Road and Lake Drive West. The proposed sanitary sewer and water improvements shall be installed by the developer and/or their assignee. The utility improvements with the exception of a portion of the storm sewer will be considered private and not maintained by the City. These utilities will be inspected by the City's Building Department. The utility improvements shall be constructed in accordance with the City's latest edition of Standard Specifications and Detail Plates and/or State Plumbing Codes. Final Plat - Chanhassen Business Center 4th Addition April 27, 1998 Page 11 This property has been previously assessed for sewer and water improvements under City Project No. 91-17. However, according to city ordinance, the property may be subject to additional sewer and water hookup charges at time of building permit issuance. Sewer and water hookup charges are determined based on the number of sewer availability charges (SAC units) which is determined by the Metropolitan Council Environmental Services upon plan review of the building. The applicant and/or contractor applying for the building permit will be responsible for the sanitary sewer and water hookup charges. 1998 hookup charges for sanitary sewer and water are $1,216 and $1,584, respectively, per unit. LANDSCAPING Existing conditions on site include boulevard trees planted along Audubon Road and Lake Drive West. No tree removal will take place. Existing trees located in proposed construction areas will be transplanted to permanent locations. Landscaping requirements for the proposed development include buffer yard plantings along Audubon Rd., landscaping for the parking lots, and boulevard trees along Lake Drive West. Applicant meets or exceeds required quantities of planting materials for parking lot landscaping (20 trees) and boulevard trees (11 trees) along Lake Drive West. Buffer yard requirements are a minimum 30' Standard C for the 475' of frontage along Audubon. Planting totals for the buffer yard are 10 overstory trees, 24 understory trees, and 24 shrubs. Existing trees in that area include 10 overstory trees. The remaining 24 understory and 24 shrubs will be required of the applicant and staff proposes they be planted adjacent to the parking lot. Along Audubon Road parallel rows of boulevard trees has been established on either side, understory and shrub planting would interrupt the consistency of the plantings and detract from the overall design of the street landscape. The additional required screening would work well of the west side of the parking lot. Staff recommends the understory trees and shrubs be planted in groupings near the edge of the parking lot. EROSION CONTROL The erosion control plan is in general conformance with the City's Best Management Practice Handbook. SURFACE WATER MANAGEMENT PLAN (SWMP) Storm Water Quality Fees The developer of Chanhassen Business Center has provided on-site water quality ponds m accordance to the SWMP, therefore, these fees have been waived. Final Plat - Chanhassen Business Center 4th Addition April 27, 1998 Page 12 Storm Water Quantity Fees The SWMP has established a connection charge for the different land uses based on an average city-wide rate for the installation of water quantity systems. This cost includes land acquisition, proposed SWMP culverts, open channels and storm water ponding areas for runoff storage. Industrial developments have a connection charge of $4,360 per developable acre. The proposed development would .then be responsible for a net area of 7.5 acres which results in a water quantity connection charge of $32,700. RECOMMENDATION SUBDIVISION APPROV AL The City Council approves the final plat for Subdivision 98-3 to replat Outlot D into 2 lots, Chanhassen Business Center 4th Addition, as shown on the plans dated received April 17, 1998, subject to the following conditions: 1. The developer shall dedicate on the final plat a 20-foot drainage and utility easement over the proposed storm sewer extension to Lot 1. 2. The developer shall enter into an amendment to the development contract for Chanhassen Business Center and provide the City with the necessary security and pay the associated final plat fees. 3. All utility improvements shall be in accordance with the City's latest edition of Standard Specifications and Detail Plates and/or State Plumbing Codes. 4. The developer shall apply for and obtain permits from the appropriate regulatory agencies, i.e. Watershed District, and comply with their conditions of approval. 5. No berming or landscaping will be allowed within the right-of-way. 6. The applicant shall report to the City Engineer the location of any draintiles found during construction and relocate or abandoned the draintiles as directed by the City Engineer. 7. If imp~rting or exporting of earthwork material is necessary, a haul route and traffic control plan shall be submitted to the City Engineer for review and approval prior to construction commencing. 8. All areas disturbed as a result of construction activities shall be immediately restored with seed and disc-mulched or wood fiber blanket and sod within two weeks of completion of each activity in accordance with the City's Best Management Practice Handbook. All city boulevards disturbed as a result of construction shall be re-sodded. Final Plat - Chanhassen Business Center 4th Addition April 27, 1998 Page 13 9. The proposed Industrial development of7.5 net developable acres is responsible for a water quantity fee of$32,700. This fee is due payable to the City prior to the City filing the final plat. 10. Driveway access to Audubon Road shall be prohibited. 11. DEVELOPMENT STANDARDS The development standards will remain the same as previously approved with the PUD. a. Intent The purpose of this zone is to create a PUD light industrial/office park. The use of the PUD zone is to allow for more flexible design standards while creating a higher quality and more sensitive proposal. All utilities are required to be placed underground. Each lot proposed for development shall proceed through site plan review based on the development standards outlined below. b. Permitted Uses The permitted uses in this zone should be limited to light industrial, warehousing, and office as defined below. The uses shall be limited to those as defined herein. If there is a question as to the whether or not a use meets the definition, the City Council shall make that interpretation. 1. Light Industrial. The manufacturing, compounding, processing, assembling, packaging, or testing of goods or equipment or research activities entirely within an enclosed structure, with no outside storage. There shall be negligible impact upon the surrounding environment by noise, vibration, smoke, dust or pollutants. 2. Warehousing. Means the commercial storage of merchandise and personal property. 3. Office. Professional and business office, non-retail activity. c. Setbacks In the PUD standards, there is the requirement for landscape buffering in addition to building and parking setbacks. The landscape buffer on Audubon Road is 50 feet, south of Lake Drive and 100 feet along the southern property line. The PUD zone requires a building to be setback 50 feet from the required landscape buffer and public right-of-ways. There is no minimum requirement for setbacks on interior lot lines. The following setbacks shall apply: Final Plat - Chanhassen Business Center 4th Addition April 27, 1998 Page 14 Ul mg ar mg Audubon Road Buffer & Setback 50' plus 50' 50' plus 10' South Property Line & Setback 100" plus 50' 1 00' plus 1 0' Front & Rear ROW on Lake Drive 25' IS' Interior Side Lot Line 10' 10' Railroad Right of Way 30' 30' Audubon Road south of Lake Drive 100' 100' BOld' P k' d. Development Standards Tabulation Box Chanhassen Business Center 4th Addition (Outlot D) Lot # Lot Size - Acres Building Sq. Ft. Building Impervious Coverage 1 2.66 57,000 29% 60% 2 4.84 44,000 25% 60% Subtotal 7.5 101,000 avg.27% avg. 60% The PUD standard for hard surface coverage is 70% for office and industrial uses. The proposed development meets this standard with an average of 56% hard surface coverage. Building Square Footage Breakdown Office 20% 120,700 sq. ft. Manufacturing 25% 150,875 sq. ft. Warehouse 54.09% 326,425 sq. ft. Church 0.91% 5,500 sq. ft. Total 100% 603,500 sq. ft. Final Plat - Chanhassen Business Center 4th Addition April 27, 1998 Page 15 e. Building Materials and Design 1. The PUD requires that the development demonstrate a higher quality of architectural standards and site design. All mechanical equipment shall be screened with material compatible to the building. 2. All materials shall be of high quality and durable. Masonry material shall be used. Color shall be introduced through colored block or panels and not painted block. 3. Brick may be used and must be approved to assure uniformity. 4. Block shall have a weathered face or be polished, fluted, or broken face. 5. Concrete may be poured in place, tilt-up or pre-cast, and shall be finished in stone, textured or coated. 6. Metal siding will not be approved except as support material to one of the above materials or curtain wall on office components or, as trim or as HV AC screen. 7. All accessory structures shall be designed to be compatible with the primary structure. 8. All roof mounted equipment shall be screened by walls of compatible appearing material. Wood screen fences are prohibited. All exterior process machinery, tanks, etc., are to be fully screened by compatible materials. 9. The use oflarge unadorned, prestressed concrete panels and concrete block shall be prohibited. Acceptable materials will incorporate textured surfaces, exposed aggregate and/or other patterning. All walls shall be given added architectural interest through building design or appropriate landscaping. 10. Space for recycling shall be provided in the interior of all principal structures for all developments in the Business Center. f. Site Landscaping and Screening 1. All buffer landscaping, including boulevard landscaping, included in Phase I area to be installed when the grading of the phase is completed. This may well result in landscaping being required ahead of individual site plan approvals but we believe the buffer yard and plantings, in particular, need to be established immediately. In addition, to adhere to the higher quality of development as spelled out in the PUD zone, all loading areas shall be screened. Each lot for development shall submit a separate landscaping plan as a part of the site plan review process. Final Plat - Chanhassen Business Center 4th Addition April 27, 1998 Page 16 2. All open spaces and non-parking lot surfaces shall be landscaped, rockscaped, or covered with plantings and/or lawn material. 3. Storage of material outdoors is prohibited unless it has been approved under site plan review. All approved outdoor storage must be screened with masonry fences and/or landscaping. 3. The master landscape plan for the CBC PUD shall be the design guide for all of the specific site landscape developments. Each lot must present a landscape plan for approval with the site plan review process. 4. Undulating or angular berms 3' to 4' in height, south of Lake Drive along Audubon Road shall be sodded or seeded at the conclusion of Phase I grading and utility construction. The required buffer landscaping may be installed incrementally, but it shall be required where it is deemed necessary to screen any proposed development. All required boulevard landscaping shall be sodded. 5. Loading areas shall be screened from public right-of-ways. Wing wall may be required where deemed appropriate. g. Signage 1. All freestanding signs be limited to monument signs. The sign shall not exceed eighty (80) square feet in sign display area nor be greater than eight (8) feet in height. The sign treatment is an element of the architecture and thus should reflect with the quality of the development. The signs should be consistent in color, size, and material throughout the development. The applicant should submit a sign package for staff review. 2. Each property shall be allowed one monument sign located near the driveway into the private site. All signs require a separate permit. 3. The signage will have consistency throughout the development. A common theme will be introduced at the development's entrance monument and will be used throughout. 4. Consistency in signage shall relate to color, size, materials, and heights. h. Lighting 1. Lighting for the interior of the business center should be consistent throughout the development. The applicant's proposal is consistent with the lighting standards for the PUD ordinance. The plans do not provide for street lighting. As with previous industrial Final Plat - Chanhassen Business Center 4th Addition April 27, 1998 Page 17 parks/roadways, the City has required the developer to install street lights throughout the street system. The street lights should be designed consistent with the existing lighting along Audubon Road. 2. A decorative, shoe box fixture (high pressure sodium vapor lamps) with a square ornamental pole shall be used throughout the development area for area lighting. 3 Lighting equipment similar to what is mounted in the public street right-of-ways shall be used in the private areas. 4. All light fixtures shall be shielded. Light level for site lighting shall be no more than 12 candle at the property line. This does not apply to street lighting." A TT ACHMENTS 1. Chanhassen Business Center Preliminary Plans. 2. City Council minutes dated April 13, 1998 3. Final Plat dated April 17, 1998. !' ~..... -~";:V. 4 ~ r~' ;' ~'~ .I'/~ lieu .."OU','1lI '..",...c) 01. 21." .a.....T:"~. ;~C1:'t.. ,:H S~l:;s.~N) ~~.~ ~rs~.::) ':lNI '511';'0055" lC~~""~") '!:f ^'rI'"r.JA "..'i<<; 'N" .]laUY~d N)O) 1atoo:>> 101S)t))liiIJ 'tEe;, dlHSliiIJNUf'fd Z6 NeSnan. tC.. --.......-- '::"'..=.. -::::-:-.::::.- ...:.:-.: --------. ." .....-~ l;.i'S blJ.S"" NOll:>mI1SNO:> MO:t 10N SN'tWI ,U'YNIWI'JWd T....ll;:;..6 .""'" s..o.slo\J. ./IrllJ".)l.t\l.j' .]~:..:...j ,,' z --: " ':! '" ...... ;-1 ; ; ~.1 ,: t;.ii ~ ! I }. ~ I z o >= is o < '" '" w z in :> '...\%\~:>;f'= 0 0 ~~O 0 ,-c,,~O 0 0 < 'J= i = == i = =" - ".'~ .... Z U'" "'. ~ ~ ~.I ~ B .~~. ~;I 5 ~I II ! ....... , - ,- '.~'J:' r ~~ .i !~ H L,-/' . .. z:' l:X~ " on" _ i~ ~ ~'f B u.j; i- ~ ! ; ~1 I' . -I ( o. 0.. ~~ ~ vo. 0- :I> 1:>. 0- : : i i : I I I ! t I Ii,! Ii :i I Il: 1 Ii Ii ,f :! l.! \ l'l~iJllll I i ih i II 'Un 'UlI 'U I I . i i 1 ; !U ; 1 nil : q ~ 1 I . I . hit 1111 uti; i "'r 'It ~ 1 'It 1 ':~ I '!l..t'.I~ IE! I I I.. .. ~ !i i i I . r I ,.~ 1 ~ I I ~ r!~ I. ~ q i !~ ~ ~ I. ~ ~ I ~ I I!~ q q q ~ I ~ bdh i i · . i:" !I I . II": j- :::: & : I i I I H! 2 I I i ~~ ~ ~ ! I I !~ ~ :; ~ :; I ~ ~ "~ " I =, ~ ~ ~ ~ :; :; ~ ~ '! :i S ..... :: : S ....... · ii111 I i.. I I i.. I I i .. . . . II iil i.......J} 1 i ae.'" \ \ H ..'t--1" z~ " ~ ll!~= " \ i~~ \ ala \\ i i .. ~ ~ ~ :; :;; ~ .! ~ ~ .. :!! ~ e .. u. ; it City Council Meeting - April 13, 1998 after.. . certain related calls then this establishment and can we do that? Roger, can we legally say that, and there's some guidelines for this. Councilman Engel: Do you want to or do we want to have more flexibility? Roger Knutson: You have substantial discretion in establishing guidelines but I'd just caution you if it were on calls, the result would be, might not be less incidents. It might just be less calls because if the folks, and I'm just speculating. If you just told the bartenders or the people that work there, don't call, I don't care what's happening. Drag the body next door. I think you have to look at the nature of the calls and how they relate to a liquor activity. Certainly you look at calls if they were things like open after hours. Serving to minors. Routine gambling. Prostitution on the premises. Those are the sort of things that most cities look more carefully at. It says there's something wrong there because the people aren't managing their business appropriately. Mayor Mancino: What would the Council like to do on this? Councilman Berquist: Well I would move that we approve the liquor license... Councilman Mason: I would second that. Councilman Engel: I'd actually like to wait and see the comparisons to other businesses while you do a numerical. These numbers are fine but I've got nothing to compare them to. Councilman Berquist: ... but there are businesses that, you know like it as we mayor may not, there are businesses that are allowed to be open and do business in this country and I look at what's being, what's going on there on a yearly basis, I do not see anything extraordinary given the type of business and the clientele. That clientele has every right to be able to do what they do. Go there and have a drink and dance and whatever else they may be involved in this that's legal. This limited number of, very limited number in my opinion, of illegal activity. I looked at it and according to the notes it's. . . I do not see as being extraordinary. Mayor Mancino:...! mean that's what it says so thank you for clarifying it for me so, with that there is a motion and a second. Councilman Berquist moved, Councilman Mason seconded to approve the on-sale intoxicating liquor license renewal for Chanhassen Bowl at 581 West 78th Street. All voted in favor, except Councilman Senn who opposed, and the motion carried with a vote of 4 to 1. REOUEST FOR PRELIMINARY PLA T APPROVAL TO REPLA T 4.84 ACRES. OUTLOT D. CHANHASSEN BUSINESS CENTER INTO TWO LOTS: CONDITIONAL USE PERMIT TO ALLOW TWO BUILDINGS ON A SINGLE LOT: AND SITE PLAN REVIEW FOR A 16.174 SO. FT. AND 23.070 SO. FT. OFFICE/W AREHOUSE BUILDING WITH OUTDOOR STORAGE: EDEN TRACE CORPORATION. Kate Aanenson: Thank you. As you indicated, the applicant is asking for a couple requests. One, to plat a lot from an outlot status into two lots and then also to get site plan approval. The site plan here is shown, shows the two buildings and that has outdoor storage. I'll go through the architecture in a minute. This is part of the Chan Business Park, which does have a PUD. The plan as proposed is consistent with the PUD. It is bordered by Audubon Road. Because it is industrial it does have a greater 25 City Council Meeting - April 13, 1998 setback. The residences in the area would be across the street on the other side of Audubon. The Weather Service would be on the, this side of the property. Mayor Mancino: Where is the Weather Service? Kate Aanenson: On this side of the property so they're not.. .then this property would be a future lot, corner lot on Lake Drive and Audubon Road. That last lot there. So it is consistent with the application. The Planning Commission did review this and recommended approval and along with that, with the architecture. There is an outdoor storage area... The outdoor storage area would be fenced, is of similar material and it does also have windows so it really doesn't look like a storage yard. Our ordinance does allow outdoor storage but does require that it be completely screened and we believe this is a very admirable job of the outdoor storage in the fact that it is consistent with the building. It does have the ability in the future to be added to a building so it could be adapted to make one of the buildings larger on the site. One of the concerns that was addressed was additional landscaping on Audubon to provide a better buffer and that has been accomplished so with that staff is recommending approval of the final plat of the outlot and approval of the site plan. There's also a development contract to approve. Mayor Mancino: Quick question. If the outdoor storage area, is that area where they could roof it and? Impervious surface, are we still under the impervious? Kate Aanenson: Yes. We're okay, yes. Actually we balanced that over the entire site because the Weather Service actually used minimal, there is some extra impervious on that. One of the other things I didn't mention also was the rooftop equipment. The Weather Service does sit down lower, so from Audubon Road this does have parapet walls so you shouldn't be able to see the rooftop equipment. Mayor Mancino: And the building height is 18 feet and the wall height is...? Kate Aanenson: I believe that's correct. Councilman Berquist: .. .outdoor storage... being constructed of? Kate Aanenson: Similar material. Councilman Berquist: Block. Kate Aanenson: It's the exact same. This cut face block with the integrated colors. Yeah I can maybe let the applicant explain that but it's very nice. It will have a steel gate also. Councilman Berquist: ... wooden sticks. Mayor Mancino: Okay, any other questions? Councilman Senn: Kate, what's the underlying zoning there? Kate Aanenson: It's PUD but the underlying would be anything that's not specifically called out in the PUD which we've adapted here showing you would be the industrial lOP standards. Councilman Senn: But the outside storage doesn't require a conditional use then? 26 City Council Meeting - April 13, 1998 Kate Aanenson: No. What the standards say is, what it says it just has to be completely screened. Councilman Senn: But is that because of the PUD then? Kate Aanenson: I believe that's in our current ordinance also. Councilman Senn: Because I thought lOP it did. Mayor Mancino: I'm sorry, what was your question? Kate Aanenson: Outdoor storage. Councilman Senn: Outdoor storage as a conditional use under lOP I thought. Mayor Mancino: .. . right here and I have... Kate Aanenson: I can find it real fast. Councilman Senn: You were going to act like you knew where it was. Go to lOP, that's where it is. Mayor Mancino: No. No, I'm looking under conditional use. Councilman Senn: No, but it's under lOP. I can tell you that. Mayor Mancino: We'll go ahead so that we, did you have any other questions? Councilman Senn: In terms of the, okay so then as far as the uses go here then, the uses have to conform to the underlying lOP, right? Okay. Kate Aanenson: Or the PUD we called specifically, like we allowed one church in there so we did call out, in a percentage and then we did an EA W on this so it is, we have a percentage broken down on page 6. Office manufacturing, warehouse so it does meet those standards. Councilman Senn: But specific use wise though it still falls under the lOP. Kate Aanenson: No. That was why we did a PUD to call out specifically the percentages. The mix we wanted in there. Anything that's not called out in the PUD would fall underneath. We don't mention parking ratios in there. We just would go, we rely back on the underlying PUD for office standards, excuse me, the underlying zoning lOP. Mayor Mancino: Ifit's not called out in the PUD. But ifit is called out in the PUD, it's that precedent. Okay, with that. Councilman Senn: I'd like to hear the answer to the question if we could before we do something. Kate Aanenson: Outdoor storage is a conditional use in the lOP. In the lOP. Councilman Berquist: How did we, how was it decided that that would have an 8 foot fence? 27 City Council Meeting - April 13, 1998 Kate Aanenson: It's 12. It's 12. Councilman Berquist: It's 12 foot? Is that addressed in, I'm asking for... Kate Aanenson: Yes it is. It's in here. Sharmin put it in here. The findings of what the screening will be and that it can be part of the building. Councilman Berquist: It's 12 feet within the ordinance? Kate Aanenson: Yes. And the intent was that it could be enclosed in the future. That's why we...the 12 feet. If someone's lease... Well the reason why we did it, it could have been one building but we felt because it really, it looks like a building. We didn't have a problem with it. A concrete block wall with windows in it will give you that interpretation. Mayor Mancino: But nothing can be piled up higher than the 12 feet. Kate Aanenson: Exactly. Councilman Senn: It cannot be visible. Kate Aanenson: It cannot be visible. It has to be completely screened within that so it would have to be lower than that, correct. Councilman Senn: Okay. What's the use or what's the outdoor storage going to be? Kate Aanenson: I'll let the applicant, whether or not he's willing to divulge that, but let me just go back to where the storage is.. . Mayor Mancino: Well we just want to make sure that. Kate Aanenson: The way it's sitting on the property, from Audubon Road, to where it's sitting, it will be completely screened and Lake Drive, that you won't be able to see down there but that was one of our concerns. Mayor Mancino: We just want to make sure obviously that, not the current user but in future years, again it's tied to the land so that nobody else can come in and make things higher than the walL.. Is the applicant, would you like to come forward? Councilman Senn: One quick question. Now, do we need... Kate Aanenson: Actually when we put that in the plans, no. Can I tell you where we addressed that under page 4 under findings. The proposed use of light industrial are consistent with the parameters established in the PUD. As to outdoor storage section.. .PUD landscaping and screening, storage of outdoor materials is prohibited unless it's been approved under the site plan. So as part of the site plan we are recommending that based on the material, base of the height, that we think it works in the system and ultimately it's the developer's desire to probably enclose that space so it's kind of, we think it's a good use of that facility. 28 City Council Meeting - April 13, 1998 Councilman Senn: I understand that but what happens in the future when.. . another user and somebody decides to exceed the 12 foot in terms of visibility? What are you going to do about it? Kate Aanenson: Then we'd cite him for being in violation of the PUD. Councilman Senn: With what? I mean you don't have a CUP. Nothing to revoke. I mean what do you do? Go back and say we revoke your site plan? Kate Aanenson: Violation. It's a violation of the city ordinance. Councilman Senn: So you just deal with it as a misdemeanor. . . Mayor Mancino: Thank you Roger for that. Is the applicant here and would the applicant like to address the City Council? Mark Undestad: My name's Mark Undestad with Eden Trace. ... worked through a lot of stuff on here to come up with a design that we think screens offloading area. Keeps things tucked away in there with the height. The wall which is put up higher. We are working with two separate clients in there. One deals in telephone cabling. They have some reels that stand 6 feet high and they don't stack those so this is how tall that would be. Also we're dealing with another company that deals in granite and marble. Those are 8 feet high so we've taken their screen to 12 feet. Looking again, that based on any elevations around there, that if anybody's driving down Audubon, coming up from the other direction, 4 to 8 feet and their wall's at 12 feet, nobody's going to see anything down inside there. And the landscaping, we've increased landscaping there. That's about it. We've put some character to the footprint there to try to make it look nice and not look like anything other than.. . Councilman Berquist: Is that.. . underground storage going to be asphalt? Or not underground storage, outdoor storage. Mark Undestad: We're looking at...Class V overlay...which one of them goes in there. Because one of them. Mayor Mancino: They're going to put marble and granite. Councilman Berquist: You're using marble and granite? ... you're going all the way down with footings? Mark Undestad: Right. Yeah, we're hoping to expand the buildings in there and just enclose those... Mayor Mancino: .. .kind of like a dome or something. .. Any other questions for Mark at this time? Any questions? Thank you very much. May I have a motion? Councilman Berquist: Move approval. Councilman Mason: Second. Councilman Berquist moved, Councilman Mason seconded to approve the Site Plan #98-3 for Eden Trace Corporation as shown on the plans dated received February 13, 1998, subject to the following conditions: 29 City Council Meeting - April 13, 1998 1. All driveway access points onto Lake Drive West shall incorporate the City's industrial driveway apron (Detail Plate No. 5207). The developer shall be responsible for relocating any conflicting street lights along Lake Drive West. 2. Rock construction entrances shall be maintained by the applicant until all parking lots are paved with a bituminous surface. In addition, all catch basin inlets shall be protected with silt fence, rock filter dikes, or hay bales as well. 3. The bituminous trail along Audubon Road shall be restored in kind within seven days after utility extension commences. 4. All drive aisles shall be revised to meet the City Code requirements (21-1101 and 20-1118). Driveway radiuses onto Lake Drive West shall be increased to 20 foot radii. 5. The storm sewer system proposed for the easterly driveway shall be extended to the lot line for future extension and use by Lot 1. 6. Sanitary sewer and water hookup charges shall be applied to the building permit. Charges shall be based upon the number of SAC units determined by the Metropolitan Council Environmental Services. The applicant shall provide the City with a financial guarantee in the amount of $2,500 to guarantee boulevard restoration as a result of the two driveway access points. The applicant shall report to the City Engineer the location or any draintiles found during construction and shall relocate or abandon the draintiles as directed by the City Engineer. 7. The contractor and/or developer shall contact the City's Engineering Department for inspection of the driveway apron and curb/street restoration prior to pouring the concrete. A 24 hour notice is required to schedule an inspection. 8. All utility improvements shall be constructed in accordance with the latest editions of the City's Standard Specifications and Detail Plates and/or State Plumbing Codes. Detailed utility plans and specifications shall be submitted in conjunction with the final plat approval for staff review and approval. The private utilities will be inspected by the City's Building Department. The developer and/or builder shall be responsible for obtaining the necessary permits from the City. 9. Applicant shall revise landscaping plan to include 24 understory trees and 24 shrubs, as required by buffer yard ordinance, near the western edge of the parking lot along Audubon Road. 10. Site plan review approval of this application is contingent upon final plat approval and recording of Chanhassen Business Center 4th Addition by the City. 11. Fire Marshal conditions: a. Please relocate the fire hydrant which sits in front of the parking stall just outside of the fenced in area on the northwest side of the property. Please relocate fire hydrant to the curb off the northwest corner of the fenced in area. MN Uniform Fire Code 1991 Section 100403. 30 City Council Meeting - April 13, 1998 b. Please relocate the fire hydrant which sits in front of parking staff on the southeast comer of Building B. Please relocate hydrant over to the northeast in order to provide access for the fire department. MN Uniform Code 1991 Section 10.403. c. Please provide a fire lane. Call fire marshal for exact location. Chanhassen Fire Department/Fire Prevention Policy #6-1991. d. The post indicator valves will need to be provided with tamper protection. Chanhassen Fire Department/Fire Prevention Policy #40-1995. e. Fire department must witness flushing of underground mains which come in the building for fire suppression systems. Chanhassen Fire Department/Fire Prevention Policy #40-1995. f. Please refer to the enclosed fire prevention policies for all requirements from the city of Chanhassen in regards to this project. g. Chanhassen Fire Department policy on fire alarm systems; Policy #1-1990. h. Chanhassen Fire Department Policy on exterior light and horn over Fire Department Sprinkler Connection; Policy #2-1990. 1. Chanhassen Fire Department Policy regarding site plans; Policy #4-1991. J. Chanhassen Fire Department Policy requirements for fire lane signage; Policy #6-1991. k. Chanhassen Fire Department Policy regarding pre-plans; Policy #7-1991. 1. Chanhassen Fire Department Policy regarding premise identification; Policy #29-1992. m. Water Service Installation Policy for Commercial and Industrial Buildings; Policy #34-1993 Chanhassen Fire Department Policy Maximum Allowed Size of Domestic Water Service on a Combination Domestic Fire Sprinkler Supply Line; Policy #36-1994. n. Chanhassen Fire Department of Fire Sprinkler Systems; Policy #40-1995. o. Chanhassen Fire Department Policy on Labeling of Fire Rated Walls; Policy #44-1997. 12. Please contact Fire Marshal for exact size and location for installation of a lock box on the side of the building for fire department access. MN Uniform Fire Code 1991 Section 10.302. 13. The applicant shall enter into a site development contract with the city and provide the necessary financial security to guarantee compliance with the terms of approval. 14. All roof mounted equipment shall be screened by walls of compatible appearing material. Wood screen fences are prohibited. All exterior process machinery, tanks etc. are to be fully screened by compatible materials. As an alternative, the applicant can use factory applied panels on the exterior to the equipment that would blend in with the building materials. 31 City Council Meeting - April 13, 1998 15. All freestanding signs shall be limited to monument signs. The sign shall not exceed eighty (80) square feet in sign display area nor be greater than eight (8) feet in height. The sign treatment is an element of the architecture and thus should reflect with the quality of the development. A common theme will be introduced at the development's entrance monument and will be used throughout. Each property shall be allowed one monument sign located near the driveway into the private site. The monument sign must maintain a ten foot setback from the property line. The signs should be consistent in color, size, and material throughout the development. The applicant should submit a sign package for staff review. A separate permit is required for all signage on site. 16. Lighting for the interior of the business center should be consistent throughout the development. A decorative, show box fixture (high pressure sodium vapor lamps) with a square ornamental pole shall be used throughout the development area for area lighting. All light fixtures shall be shielded. Light level for site lighting shall be no more than 12 foot candle at the property line. This does not apply to street lighting. Lighting equipment similar to what is mounted in the public street right-of-ways shall be used in the private areas. Wall pack units may be used provided no direct glare is directed off-site and no more than 12 foot candle of light is at the property line. 17. Park fees shall be paid in accordance with city ordinance requirements. Also to approve Preliminary Plat for Subdivision #98-3 to replat Outlot D into two lots, Chanhassen Business Center Fourth Addition as shown on the plans dated Received February 13, 1998, subject to the following conditions: 1. Final plat shall be named Chanhassen Business Center 4th Addition. 2. The developer shall dedicate to the City a 20-foot wide trail easement over the existing trail adjacent to the Audubon Road and a 20-foot drainage and utility easement over the proposed storm sewer extension to Lot 1. 3. The developer shall enter into an amendment to the development contract for Chanhassen Business Center and provide the City with the necessary security and pay the associated final plat fees. 4. The developer shall be responsible for extending sewer and water service to the development. Sanitary sewer service shall be extended from Audubon Road for Lot 2 and Lake Drive West for Lot 1. Open cutting of Lake Drive West shall be prohibited. The developer will also be responsible for extending storm sewer service to Lot 1 from Lake Drive West. All utility improvements shall be in accordance with the City's latest edition of Standard Specifications and Detail Plates and/or State Plumbing Codes. ./ 5. The developer shall prepare a grading, drainage, and erosion control plan for both lots for review and approval by the City. 6. The applicant shall provide detailed storm sewer calculations and drainage maps for a 10- and 100-year storm event, 24-hour duration for the City Engineer to review and approve prior to final plat approval. 7. The developer shall apply for and obtain permits from the appropriate regulatory agencies, i.e. Watershed District, and comply with their conditions of approval. 32 City Council Meeting - April 13, 1998 8. No berming or landscaping will be allowed within the right-of-way. 9. The applicant shall report to the City Engineer the location of any draintiles found during construction and relocate or abandoned the drain tiles as directed by the City Engineer. 10. If importing or exporting of earthwork material is necessary, a haul route and traffic control plan shall be submitted to the City Engineer for review and approval prior to construction commencmg. 11. All areas disturbed as a result of construction activities shall be immediately restored with seed and disc-mulched or wood fiber blanket and sod within two weeks of completion of each activity in accordance with the City's Best Management Practice Handbook. All city boulevards disturbed as a result of construction shall be re-sodded. 12. The proposed Industrial development of 1.8 net developable acres is responsible for a water quantity fee of $7,848. This fee is due payable to the City prior to the City filing the final plat. 13. DEVELOPMENT STANDARDS The development standards will remain the same as previously approved with the PUD. a. Intent The purpose of this zone is to create a PUD light industrial/office park. The use of the PUD zone is to allow for more flexible design standards while creating a higher quality and more sensitive proposal. All utilities are required to be placed underground. Each lot proposed for development shall proceed through site plan review based on the development standards outlined below. b. Permitted Uses The permitted uses in this zone should be limited to light industrial, warehousing, and office as defined below. The uses shall be limited to those as defined herein. If there is a question as to the whether or not a use meets the definition, the City Council shall make that interpretation. 1. Light Industrial. The manufacturing, compounding, processing, assembling, packaging, or testing of goods or equipment or research activities entirely within an enclosed structure, with no outside storage. There shall be negligible impact upon the surrounding environment by noise, vibration, smoke, dust or pollutants. 2. Warehousing. Means the commercial storage of merchandise and personal property. 3. Office. Professional and business office, non-retail activity. c. Setbacks In the PUD standards, there is the requirement for landscape buffering in addition to building and parking setbacks. The landscape buffer on Audubon Road is 50 feet, south of Lake Drive and 100 feet along the southern property line. The PUD zone requires a building to be setback 50 feet from the required 33 City Council Meeting - April 13, 1998 landscape buffer and public right-of-ways. There is no minimum requirement for setbacks on interior lot lines. The following setbacks shall apply: B 'ld' k' Ul mg Par mg Audubon Road Buffer & Setback 50' plus 50' 50' plus 10' South Property Line & Setback 100" plus 50' 100' plus 10' Front & Rear ROW on Lake Drive 25' 15' Interior Side Lot Line 10' 10' Railroad Right of Way 30' 30' Audubon Road south of Lake Drive 100' 100' d. Development Standards Tabulation Box Chanhassen Business Center Fourth Addition (Outlot D) Chanhassen Business Center Fourth Addition (Outlot D) Lot # Lot Size - Acres Building Sq. F1. Building Coverage Impervious 1 4.5 57,000 29% 60% 2 4.0 44,000 25% 60% Subtotal 8.5 101,000 avg. 27% avg. 60% The PUD standard for hard surface coverage is 70% for office and industrial uses. The proposed development meets this standard with an average of 56% hard surface coverage. Building Square Footage Breakdown Office 20% 120,700 sq. f1. Manufacturing 25% 150,875 sq. ft. Warehouse 54.09% 326,425 sq. ft. Church 0.91% 5,500 sq. ft. Total 100% 603,500 sq. f1. e. Building Materials and Design 1. The PUD requires that the development demonstrate a higher quality of architectural standards and site design. All mechanical equipment shall be screened with material compatible to the building. 34 City Council Meeting - April 13, 1998 2. All materials shall be of high quality and durable. Masonry material shall be used. Color shall be introduced through colored block or panels and not painted block. 3. Brick may be used and must be approved to assure uniformity. 4. Block shall have a weathered face or be polished, fluted, or broken face. 5. Concrete may be poured in place, tilt-up or pre-cast, and shall be finished in stone, textured or coated. 6. Metal siding will not be approved except as support material to one of the above materials or curtain wall on office components or, as trim or as HV AC screen. 7. All accessory structures shall be designed to be compatible with the primary structure. 8. All roof mounted equipment shall be screened by walls of compatible appearing material. Wood screen fences are prohibited. All exterior process machinery, tanks, etc., are to be fully screened by compatible materials. 9. The use oflarge unadorned, prestressed concrete panels and concrete block shall be prohibited. Acceptable materials will incorporate textured surfaces, exposed aggregate and/or other patterning. All walls shall be given added architectural interest through building design or appropriate landscaping. 10. Space for recycling shall be provided in the interior of all principal structures for all developments in the Business Center. f. Site Landscaping and Screening 1. All buffer landscaping, including boulevard landscaping, included in Phase I area to be installed when the grading of the phase is completed. This may well result in landscaping being required ahead of individual site plan approvals but we believe the buffer yard and plantings, in particular, need to be established immediately. In addition, to adhere to the higher quality of development as spelled out in the PUD zone, all loading areas shall be screened. Each lot for development shall submit a separate landscaping plan as a part of the site plan review process. 2. All open spaces and non-parking lot surfaces shall be landscaped, rockscaped, or covered with plantings and/or lawn material. 3. Storage of material outdoors is prohibited unless it has been approved under site plan review. All approved outdoor storage must be screened with masonry fences and/or landscaping. 3. The master landscape plan for the CBC PUD shall be the design guide for all of the specific site landscape developments. Each lot must present a landscape plan for approval with the site plan review process. 4. Undulating or angular berms 3' to 4' in height, south of Lake Drive along Audubon Road shall be sodded or seeded at the conclusion of Phase I grading and utility construction. The required buffer 35 City Council Meeting - April 13, 1998 landscaping may be installed incrementally, but it shall be required where it is deemed necessary to screen any proposed development. All required boulevard landscaping shall be sodded. 5. Loading areas shall be screened from public right-of-ways. Wing wall may be required where deemed appropriate. g. Sign age 1. All freestanding signs be limited to monument signs. The sign shall not exceed eighty (80) square feet in sign display area nor be greater than eight (8) feet in height. The sign treatment is an element of the architecture and thus should reflect with the quality of the development. The signs should be consistent in color, size, and material throughout the development. The applicant should submit a sign package for staff review. 2. Each property shall be allowed one monument sign located near the driveway into the private site. All signs require a separate permit. 3. The signage will have consistency throughout the development. A common theme will be introduced at the development's entrance monument and will be used throughout. 4. Consistency in signage shall relate to color, size, materials, and heights. h. Lighting 1. Lighting for the interior of the business center should be consistent throughout the development. The applicant's proposal is consistent with the lighting standards for the PUD ordinance. The plans do not provide for street lighting. As with previous industrial parks/roadways, the City has required the developer to install street lights throughout the street system. The street lights should be designed consistent with the existing lighting along Audubon Road. 2. A decorative, shoe box fixture (high pressure sodium vapor lamps) with a square ornamental pole shall be used throughout the development area for area lighting. 3 Lighting equipment similar to what is mounted in the public street right-of-ways shall be used in the private areas. 4. All light fixtures shall be shielded. Light level for site lighting shall be no more than 1/2 candle at the property line. This does not apply to street lighting." All voted in favor and the motion carried unanimously. CENTEX HOMES. LOCATED SOUTH OF LAKE LUCY ROAD BETWEEN GALPIN BOULEY ARD AND BRlARWOOD COURT. WOODRlDGE HEIGHTS 3RD ADDITION: A. REQUEST FOR Y ACATION OF EXISTING DRAINAGE AND UTILITY EASEMENTS DUE TO THE REPLAT. B. PRELIMINARY AND FINAL PLAT TO REPLAT FOUR LOTS INTO FIVE LOTS. C. AMENDMENT TO DEVELOPMENT CONTRACT. 36