Loading...
C2.2 SITE PLAN SOUTH40163 UPD.C COMM 952.21 40165 UPD.C 952.10 45219 FNB B 948.62 PROPOSED BUILDING FFE=952.50 COLD STORAGE BUILDING FFE=952.50 COLD STORAGE BUILDING FFE=952.50 COLD STORAGE BUILDING FFE=952.50 25' PARKING SETBACK 30' BUILDING SETBACK 25' PARKING SETBACK 10' BUILDING SETBACK 30'R 30'R 515'R 20'R 5'R 485'R 30'R 3'R 10'R 10'R 10'R 10'R 15'R 513'R 15'R 487'R 10'R 17.5'16.0'10.0'80.5'30.0'60.2'13.0'TYP22.0'64.5'26.6'32.0'164.8' 5.2' 5.5' 10'R 10'R 3'R 3'R3'R 3'R 45.7'46.8'30.0' 26.0'30.7'25.0'30.0'10. 0 ' 25. 0 ' 10 46.8'44.8'24.2'2.0'44.5'50' AVERAGE BUFFER AREA 30' MINIMUM BUFFER AREA 30.0 ' 17-WETLAND BUFFER LOCATION SIGNS TYP-SEE DETAIL 30.0 '30.0 ' 50' AVERAGE BUFFER AREA 30' MINIMUM BUFFER AREA 50' AVERAGE BUFFER AREA 30' MINIMUM BUFFER AREA CONCRETE APRON TYP-SEE DETAIL HEAVY DUTY BITUMINOUS PAVEMENT TYP-SEE DETAIL MATCH EXISTING MATCH EXISTING CURB & GUTTER, SIDEWALK AND BITUMINOUS PAVEMENT MATCH EXISTING CURB & GUTTER, SIDEWALK AND BITUMINOUS PAVEMENT CONCRETE SIDEWALK TYP-SEE DETAIL HEAVY DUTY BITUMINOUS PAVEMENT TYP-SEE DETAIL MATCH EXISTING MATCH EXISTING CURB & GUTTER, SIDEWALK AND BITUMINOUS PAVEMENT MATCH EXISTING SIDEWALK MATCH EXISTING SIDEWALK MATCH EXISTING SIDEWALK CONCRETE APRON TYP-SEE DETAIL MATCH EXISTING CURB & GUTTER, SIDEWALK AND BITUMINOUS PAVEMENT EXISTING LIGHT POLE TO REMAIN PROTECT DURING CONSTRUCTION SURMOUNTABLE CURB & GUTTER TYP-SEE DETAIL HEAVY DUTY BITUMINOUS PAVEMENT TYP-SEE DETAIL FLAT CURB TYP-SEE DETAIL 3' CURB TAPER 3' CURB TAPER SECURITY FENCE SEE LANDSCAPE PLANS SECURITY ACCESS CARD READER SEE ELECTRICAL PLANS SECURITY GATE SEE ARCHITECTURAL PLANS CONCRETE PAVEMENT TYP-SEE DETAIL B612 CURB & GUTTER TYP-SEE DETAIL SECURITY FENCE SEE LANDSCAPE PLANS LARGE BLOCK RETAINING WALL TYP-SEE DETAIL HEAVY DUTY BITUMINOUS PAVEMENT TYP-SEE DETAIL CONCRETE PAVEMENT TYP-SEE DETAIL 3.0'CONCRETE PAVEMENT TYP-SEE DETAIL3.0'SECURITY ACCESS CARD READER SEE ELECTRICAL PLANS5.0' CONCRETE PAVEMENT TYP-SEE DETAIL SECURITY GATE TYP-SEE DETAIL COORDINATE W/ OWNER & ELECTRICAL FOR CARD READER CONCRETE SIDEWALK TYP-SEE DETAIL CONCRETE PAVEMENT TYP-SEE DETAIL 3.0' FLAT CURB TYP-SEE DETAIL 3' TAPER TO FLAT CURB B612 CURB & GUTTER TYP-SEE DETAIL B612 CURB & GUTTER TYP-SEE DETAIL CONCRETE PAVEMENT TYP-SEE DETAIL 20.0' 26.5' (10) CONCRETE BOLLARD TYP-SEE DETAIL (8) CONCRETE BOLLARD TYP-SEE DETAIL STORAGE BINS SEE ARCHITECTURAL PLANS SNOW STORAGE AREA SURMOUNTABLE CURB & GUTTER TYP-SEE DETAIL TELECOMMUNICATIONS TOWER PROVIDED BY OWNER CURB TRANSITION SURMOUNTABLE CURB & GUTTER TYP-SEE DETAIL (20) 24"X24" PRECAST CONCRETE BASES FOR POLE STORAGE BUNKERS COORDINATE WITH OWNER GRAVEL PAVEMENT TYP-SEE DETAIL SNOW STORAGE AREA SOUTH POND SEE GRADING PLANS REMOVE & REPLACE EXISTING SIDEWALK AS NEEDED FOR UTILITY CONSTRUCTION MATCH EXISTING SECTION REFER TO UTILITY PLANS MATCH EXISTING SIDEWALK MATCH EXISTING SIDEWALK B612 CURB & GUTTER TYP-SEE DETAIL SNOW STORAGE AREA STORAGE BINS SEE ARCHITECTURAL PLANS CURB TRANSITION B612 CURB & GUTTER TYP-SEE DETAIL 5'R (1) ELECTRIC VEHICLE CHARGING STATION BASE TYP-SEE DETAIL COORDINATE WITH ELECTRIC PLANS & OWNER (2) BOLLARDS AROUND ELECTRIC VEHICLE CHARGING STATION TYP-SEE DETAIL COORDINATE WITH ELECTRIC PLANS & OWNER (2) ELECTRIC VEHICLE CHARGING STATION SIGNS TYP-SEE DETAIL (6) FUTURE ELECTRIC VEHICLE CHARGING STATION SIGNS TYP-SEE DETAIL (3) FUTURE ELECTRIC VEHICLE CHARGING STATION BASES TYP-SEE DETAIL COORDINATE WITH ELECTRIC PLANS & OWNER (6) BOLLARDS AROUND FUTURE ELECTRIC VEHICLE CHARGING STATION TYP-SEE DETAIL COORDINATE WITH ELECTRIC PLANS & OWNER SECURITY GATE SEE LANDSCAPE PLANS COORDINATE W/ OWNER & ELECTRICAL FOR CARD READER 16' DOUBLE SWING GATE SEE LANDSCAPE PLANS TYP-SEE DETAIL (18) CONCRETE BOLLARD TYP-SEE DETAIL (10) CONCRETE BOLLARD TYP-SEE DETAIL CONCRETE PAVEMENT PADS FOR ELECTRICAL & MECHANICAL EQUIPMENT COORDINATE W/ EQUIPMENT SUPPLIER, ELECTRICAL, & MECHANICAL FOR EXACT SIZE, EQUIPMENT LAYOUT, BOLLARD PLACEMENT, PAVEMENT SECTION, AND REINFORCEMENT REQUIREMENTS 16' DOUBLE SWING GATE SEE LANDSCAPE PLANS CONCRETE SIDEWALK TYP-SEE DETAIL LIGHT POLE-TYP SEE ELECTRICAL PLANS B612 CURB & GUTTER TYP-SEE DETAIL 30.7'26.0'28.4' TAPER TO FLAT CURB TYP-SEE DETAIL TAPER TO FLAT CURB TYP-SEE DETAIL SURMOUNTABLE CURB & GUTTER TYP-SEE DETAIL CURB TRANSITION LIGHT POLE-TYP SEE ELECTRICAL PLANS N SCALE IN FEET 0 30 60 NORTH KEY PLAN DRAWING NUMBER DRAWING TITLE CLIENT 4201 cedar avenue so. - minneapolis, MN 55407 tel. (612) 904-1332 - fax (612) 904-7366 NOT F O R C O N S T R U C TI O N PROJECT NUMBER 21602.0A REVISION DATE DESCRIPTION BY 1891 Arboretum Boulevard Chanhassen, MN 55317 Xcel Energy Service Center Chanhassen Title: Zachary B. Moen - PE Registration Number: 58688 Date: XX/XX/XXXX By: Title: Professional Engineer I hereby certify that this drawing was prepared by me or under my direct supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota. LOUCKS PROJECT NO. 21602 10/25/2022 WATERSHED SUBMITTAL 11/16/2022 TEP SUBMITTAL 11/16/2022 SCHEMATIC DESIGN PACKAGE 12/05/2022 SD PACKAGE ADDENDUM 01/12/2023 CITY SUBMISSION C2.2 SITE PLAN SOUTH NOTE: EXISTING CONDITIONS INFORMATION SHOWN IS FROM AN ALTA/NSPS LAND TITLE SURVEY PREPARED BY LOUCKS, DATED 03/24/2022. PARKING STALL COUNT ACCESSIBLE PARKING STALL 2 LEGEND CATCH BASIN STORM SEWER SANITARY SEWER WATERMAIN STORM MANHOLE SANITARY MANHOLE HYDRANT GATE VALVE SPOT ELEVATION SIGN LIGHT POLE POWER POLE WATER MANHOLE / WELL CONTOUR CONCRETE CURB UNDERGROUND ELECTRIC CONCRETE TELEPHONE PEDESTAL UNDERGROUND TELEPHONE UNDERGROUND GAS OVERHEAD UTILITY CHAIN LINK FENCE BUILDING RETAINING WALL NO PARKING UNDERGROUND FIBER OPTIC SANITARY SEWER SERVICE WATER SERVICE ELECTRIC METER GAS METER TREE LINE EXISTING PROPOSED 972 DRAINTILE FORCEMAIN 373PARKING SETBACK LINE BUILDING SETBACK LINE 2 FENCE FLARED END SECTION POST INDICATOR VALVE BENCHMARK SOIL BORING 3DIRECTION OF FLOW 1.0% 972.5 Gopher State One Call WARNING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. NOTE: SEE PAVEMENT SECTIONS ON SHEET C8.1 OR C8.4 FOR TYPE AND DEPTH INFORMATION. LIGHT DUTY BITUMINOUS PAVEMENT CONCRETE SIDEWALK HEAVY DUTY BITUMINOUS PAVEMENT CONCRETE PAVEMENT PAVEMENT TYPES GRAVEL AREA NOTE: SEE CURB & GUTTER DETAILS ON SHEET C8.4 CURB TYPES B612 CURB & GUTTER (STANDARD) B612 CURB & GUTTER (TIP OUT) FLAT CURB & GUTTER (STANDARD) FLAT CURB & GUTTER (TIP OUT) SURMOUNTABLE CURB & GUTTER (STANDARD) SURMOUNTABLE CURB & GUTTER (TIP OUT) BUILDING INFORMATION MAIN BUILDING CREW AREA: 9,440 SF WAREHOUSE:12,480 SF VEHICLE STORAGE:39,844 SF MAIN OFFICE:10,866 SF MECHANICAL: 7,363 SF TOTAL AREA:79,993 SF BUILDING HEIGHT: OFFICE/WAREHOUSE (2-STORY):21'-6" VEHICLE STORAGE (1-STORY):31'-6" FLEET MAINTENANCE BUILDING FLEET MAINTENANCE:17,580 SF MEZZANINE STANDARD: 3,108 SF MEZZANINE HIGH: 4,012 SF TOTAL AREA:24,700 SF BUILDING HEIGHT: STANDARD BAY (1-STORY):36'-0" HIGH BAY (1-STORY):61'-0" PROJECTED TOTAL NUMBER OF EMPLOYEES:68 1.ALL PAVING, CONCRETE CURB, GUTTER AND SIDEWALK SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH THE DETAILS SHOWN PER THE DETAIL SHEET(S) AND APPLICABLE GOVERNING AGENCY REQUIREMENTS. 2.ACCESSIBLE PARKING AND ACCESSIBLE ROUTES SHALL BE PROVIDED PER CURRENT ADA STANDARDS AND APPLICABLE GOVERNING AGENCY REQUIREMENTS. 3.ALL CURB DIMENSIONS SHOWN ARE TO THE FACE OF CURB UNLESS OTHERWISE NOTED. 4.ALL BUILDING DIMENSIONS ARE TO THE OUTSIDE FACE OF WALL UNLESS OTHERWISE NOTED. 5.BITUMINOUS IMPREGNATED FIBER BOARD TO BE PLACED AT FULL DEPTH OF CONCRETE ADJACENT TO EXISTING STRUCTURES AND BEHIND CURB ADJACENT TO DRIVEWAYS AND SIDEWALKS. 6.SEE SITE ELECTRICAL PLAN FOR SITE LIGHTING. 7.REFER TO THE GEOTECHNICAL REPORT PREPARED BY BRAUN INTERTEC FOR AN EXISTING SUBSURFACE SITE CONDITION ANALYSIS AND CONSTRUCTION RECOMMENDATIONS INCLUDING BUT NOT LIMITED TO PAVEMENTS AND EXTERIOR SLABS. SITE NOTES CURRENT ZONING: A2 (AGRICULTURAL ESTATE DISTRICT) PROPOSED ZONING: PUD (PLANNED UNIT DEVELOPMENT) PROPERTY AREA (GROSS): 23.56 AC (1,026,095 SF) RIGHT OF WAY AREA: 1.82 AC BUILDABLE PROPERTY AREA (NET): 21.74 AC PROPOSED BUILDING AREA: 2.420 AC (11.1%)* PROPOSED IMPERVIOUS PARKING AREA: 1.082 AC (5.0%)* PROPOSED REMAINING SITE IMPERVIOUS AREA:5.913 AC (27.2%)* PROPOSED TOTAL IMPERVIOUS AREA: 9.415 AC (43.3%)* DISTURBED AREA: 17.200 AC EXISTING IMPERVIOUS AREA: 0.000 AC* PROPOSED IMPERVIOUS AREA: 9.415 AC* *BASED ON NET BUILDABLE PROPERTY AREA ONLY SITE DATA 1.CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SITE SIGNAGE AND STRIPING AS SHOWN ON THIS PLAN. 2.CONTRACTOR SHALL PAINT ALL ACCESSIBLE STALLS, LOGOS AND CROSS HATCH LOADING AISLES WITH WHITE OR YELLOW PAVEMENT MARKING PAINT, 4" IN WIDTH. 3.CONTRACTOR SHALL PAINT ANY/ALL DIRECTIONAL TRAFFIC ARROWS, AS SHOWN, IN WHITE OR YELLOW PAINT. 4.ALL SIGNAGE SHALL INCLUDE POST, CONCRETE FOOTING AND STEEL CASING WHERE REQUIRED. 5.ALL SIGNAGE NOT PROTECTED BY CURB, LOCATED IN PARKING LOT OR OTHER PAVED AREAS TO BE PLACED IN STEEL CASING, FILLED WITH CONCRETE AND PAINTED YELLOW. REFER TO DETAIL(S). 6.ANY/ALL STOP SIGNS TO INCLUDE A 24" WIDE PAINTED STOP BAR IN WHITE PAINT, PLACED AT THE STOP SIGN LOCATION, A MINIMUM OF 4' FROM CROSSWALK IF APPLICABLE. ALL STOP BARS SHALL EXTEND FROM DIRECTIONAL TRANSITION BETWEEN LANES TO CURB. 7.ALL SIGNS TO BE PLACED 18" BEHIND BACK OF CURB UNLESS OTHERWISE NOTED. SIGNAGE AND STRIPING NOTES NE WETLAND 40' WETLAND BUFFER AREA REQUIRED = 20,685 SF 40' AVERAGE WETLAND BUFFER AREA PROVIDED = 29,390 SF WEST CREEK 50' CREEK BUFFER AREA REQUIRED = 82,390 SF 50' AVERAGE CREEK BUFFER AREA PROVIDED = 82,670 SF WETLAND BUFFER DATA YARD (BUILDING) SETBACKS: FRONT 30 FT MINIMUM SIDE 10 FT MINIMUM REAR 10 FT MINIMUM HWY 5 CORRIDOR OVERLAY DISTRICT: BUILDING SETBACK 70 FT MINIMUM 150 FT MAXIMUM OFF-STREET PARKING SETBACKS: FRONT 25 FT MINIMUM SIDE 25 FT MINIMUM REAR 25 FT MINIMUM MINIMUM PARKING LAYOUT DIMENSIONS (90 DEGREE PATTERN): PARKING SPACE WIDTH = 9 FT PARKING SPACE LENGTH = 18 FT DRIVE LANE WIDTH = 26 FT TOTAL PARKING PROVIDED = 120 STALLS PROPOSED ACCESSIBLE PARKING:6 STALLS REQUIRED ACCESSIBLE PARKING:6 STALLS** **REQUIRED MINIMUM NUMBER OF ACCESSIBLE SPACES FOR 151 TO 200 STALLS DEVELOPMENT AND DESIGN STANDARDS OFF-STREET PARKING CALCULATIONS ACCESSIBLE PARKING