Loading...
C4.2 UTILITY PLAN SOUTH STORM SEWER40163 UPD.C COMM 952.21 40165 UPD.C 952.10444444444444444 88888888888888888888888888888888888888888888888888888888888 PROPOSED BUILDING FFE=952.50 COLD STORAGE BUILDING FFE=952.50 COLD STORAGE BUILDING FFE=952.50 COLD STORAGE BUILDING FFE=952.5088888 88888444444FES 20 W/ RIP RAP INV=942.00 FES 10 W/ RIP RAP INV=931.10 (PUBLIC STRUCTURE) 173 LF-24" PVC @ 1.0% STMH 11 RIM=951.12 INV(E)=938.15 INV(W)=931.50 (PUBLIC STRUCTURE) CBMH 22 RIM=948.75 INV(N,S)=944.56 INV(W)=944.06 CBMH 30 RIM=949.45 INV=944.95 58 LF-12" HDPE @ 0.7% 179 LF-12" HDPE @ 1.6% CBMH 32 RIM=957.85 INV(N)=955.85 INV(S)=953.85 INV(NW)=948.50 74 LF-12" HDPE @ 4.2% CBMH 33 RIM=960.43 INV(W)=958.43 INV(N)=956.93 4" PVC DRAINTILE FINGER DRAIN SLOPE TO DRAIN-TYP 131 LF-FRENCH DRAIN W/ 6" PERFORATED PVC @ 2.0% SEE DETAIL 83 LF-12" HDPE @ 0.5% CBMH 23 RIM=949.08 INV=945.41 CBMH 24 RIM=949.42 INV=945.83 199 LF-42" RCP @ 1.25% (PUBLIC PIPE)STMH 12 RIM=951.34 INV=940.64 (PUBLIC STRUCTURE) 82 LF-18" HDPE @ 1.0% CBMH 100 RIM=951.06 INV(NE)=945.91 INV(N)=945.83 INV(W)=945.41 INV(S)=951.64 INV(W)=951.54 252 LF-12" HDPE @ 1.5% CB 122 RIM=959.42 INV=955.42 OUTLET INV=945.35 17 LF-21" CMP @ 3.25% REUSE TANK 306 LF-72" SOLID CMP TOP= 949.50 INV= 943.50 SEE DETAIL 75 LF-60" RCP @ 0.5% (PUBLIC PIPE) OCS 2 RIM=945.00 INV(E)=936.50 WEIR= 943.00 ORIFICE(9"Wx6"H)= 942.00 INV(W)=934.00 FES 3 INV=936.00 48 LF-30" RCP @ 1.0% 116 LF-30" RCP @ 7.76% SOUTH POND TOP OF BERM= 946.50 EOF= 946.00 NWL= 942.00 BOT= 933.00 HWL= 944.40 WEIR OVERFLOW 10' INV= 946.00 CB 92 RIM=949.78 INV(E)=947.03 INV(N)=946.53 114 LF-12" HDPE @ 0.50% CBMH 90 RIM=950.47 INV(SW)=945.96 INV(N,E)=945.45 STMH 80 W/DISSIPATOR & SKIMMER RIM=950.91 INV(SE)=945.21 INV(NW,E)=944.27 SUMP=939.27 15 LF-18" HDPE @ 1.6% 227 LF-24" PVC @ 0.5% CLEANOUT RIM=963.04 INV=961.04 CLEANOUT RIM=964.10 INV=962.10 74 LF-FRENCH DRAIN W/ 6" PERFORATED PVC @ 8.4% SEE DETAIL 4" PVC DRAINTILE FINGER DRAIN SLOPE TO DRAIN-TYP 4" PVC DRAINTILE FINGER DRAIN SLOPE TO DRAIN-TYP 4" PVC DRAINTILE FINGER DRAIN SLOPE TO DRAIN-TYP 83 LF-12" HDPE @ 1.0% ACCESS RISER RIM=951.70 INV=943.50 ACCESS RISER RIM=952.05 INV=943.50 RIM=951.52 INV=943.50 12" ROOF DRAIN STUB INV=948.00 75 LF-12" PVC @ 1.0% W/ INSULATION (VERIFY LOCATION, INVERT, & SIZE W/ MECHANICAL) INLET INV=947.25 INLET INV=947.25 INLET INV=947.25 75 LF-12" PVC @ 1.0% PIPING TO PUMP SYSTEM FOR TRUCK WASHING SYSTEM SEE MECHANICAL FOR PUMP DESIGN & ASSOCIATED INFRASTRUCTURE 30 LF-24" HDPE @ 1.0% OUTLET INV=943.50 STMH 31 RIM=952.45 INV(N,S)=948.30 INV(SE,NW)=947.80 45 LF-12" HDPE @ 1.6% CBMH 25 RIM=949.75 INV(N)=946.75 INV(S)=946.25 83 LF-12" HDPE @ 0.5% W/ INSULATION (VERIFY LOCATION, INVERT, & SIZE W/ MECHANICAL) AREA TO BE OVER-EXCAVATED PRIOR TO RIP-RAP INSTALLATION. NO FILL TO BE PLACED WITHIN 100-YEAR FLOODPLAIN. INV(W)=949.07 86 LF-12" HDPE @ 2.75% 12" TOP=947.30 12" BOT=946.00 60" TOP=936.77 60" BOT=930.77 STMH 21 W/DISSIPATOR & SKIMMER RIM=950.58 INV=943.73 SUMP=938.73 8 LF-21" CMP @ 1.25% FES 1 W/ RIPRAP INV=925.00 40' STORM SEWER EASEMENT 8" TOP=938.64 8" BOT=937.87 60" TOP=936.90 60" BOT=930.90 N SCALE IN FEET 0 30 60 NORTH KEY PLAN DRAWING NUMBER DRAWING TITLE CLIENT 4201 cedar avenue so. - minneapolis, MN 55407 tel. (612) 904-1332 - fax (612) 904-7366 NOT F O R C O N S T R U C TI O N PROJECT NUMBER 21602.0A REVISION DATE DESCRIPTION BY 1891 Arboretum Boulevard Chanhassen, MN 55317 Xcel Energy Service Center Chanhassen Title: Zachary B. Moen - PE Registration Number: 58688 Date: XX/XX/XXXX By: Title: Professional Engineer I hereby certify that this drawing was prepared by me or under my direct supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota. LOUCKS PROJECT NO. 21602 10/25/2022 WATERSHED SUBMITTAL 11/16/2022 TEP SUBMITTAL 11/16/2022 SCHEMATIC DESIGN PACKAGE 12/05/2022 SD PACKAGE ADDENDUM 01/12/2023 CITY SUBMISSION C4.2 UTILITY PLAN SOUTH STORM SEWER NOTE: EXISTING CONDITIONS INFORMATION SHOWN IS FROM AN ALTA/NSPS LAND TITLE SURVEY PREPARED BY LOUCKS, DATED 03/24/2022. PARKING STALL COUNT ACCESSIBLE PARKING STALL 2 LEGEND CATCH BASIN STORM SEWER SANITARY SEWER WATERMAIN STORM MANHOLE SANITARY MANHOLE HYDRANT GATE VALVE SPOT ELEVATION SIGN LIGHT POLE POWER POLE WATER MANHOLE / WELL CONTOUR CONCRETE CURB UNDERGROUND ELECTRIC CONCRETE TELEPHONE PEDESTAL UNDERGROUND TELEPHONE UNDERGROUND GAS OVERHEAD UTILITY CHAIN LINK FENCE BUILDING RETAINING WALL NO PARKING UNDERGROUND FIBER OPTIC SANITARY SEWER SERVICE WATER SERVICE ELECTRIC METER GAS METER TREE LINE EXISTING PROPOSED 972 DRAINTILE FORCEMAIN 373PARKING SETBACK LINE BUILDING SETBACK LINE 2 FENCE FLARED END SECTION POST INDICATOR VALVE BENCHMARK SOIL BORING 3DIRECTION OF FLOW 1.0% 972.5 Gopher State One Call WARNING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. STORM SEWER NOTES 1.ALL STORM SEWER SHALL BE FURNISHED AND INSTALLED PER THE REQUIREMENTS OF THE SPECIFICATIONS,THE MINNESOTA PLUMBING CODE, THE LOCAL GOVERNING UNIT, AND THE STANDARD UTILITIES SPECIFICATION OF THE CITY ENGINEERS ASSOCIATION OF MINNESOTA (CEAM), CURRENT EDITION. 2.ALL UTILITY PIPE BEDDING SHALL BE COMPACTED SAND OR FINE GRANULAR MATERIAL. ALL COMPACTION SHALL BE PERFORMED PER THE REQUIREMENTS OF THE CEAM SPECIFICATION AND THE GEOTECHNICAL REPORT. 3.ALL CONNECTIONS TO EXISTING UTILITIES SHALL BE PERFORMED PER THE REQUIREMENTS OF THE STATE AND LOCAL JURISDICTIONS. THE CITY DEPARTMENT OF ENGINEERING AND BUILDING INSPECTIONS DEPARTMENT AND THE CONSTRUCTION ENGINEER MUST BE NOTIFIED AT LEAST 48 HOURS PRIOR TO ANY WORK WITHIN THE PUBLIC RIGHT OF WAY, OR WORK IMPACTING PUBLIC UTILITIES. 4.ALL SITE UTILITY SERVICES SHALL TERMINATE 5' FROM THE EXTERIOR BUILDING WALL UNLESS OTHERWISE NOTED. THE SITE UTILITY CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR, MECHANICAL CONTRACTOR AND MECHANICAL ENGINEER TO DETERMINE THE RESPONSIBILITY OF BRINGING THE SERVICE(S) INTO THE BUILDING, INSPECTIONS AND TESTING PER APPLICABLE GOVERNING AGENCIES. 5.PER MINNESOTA DEPARTMENT OF LABOR & INDUSTRY REQUIREMENTS, A MINIMUM OF 18 INCHES OF VERTICAL SEPARATION AND 10 FEET OF HORIZONTAL SEPARATION IS REQUIRED FROM WATERMAIN TO ANY MANHOLE, SEPTIC SYSTEM, CATCH BASIN, SEWER PIPE, OR OTHER SOURCE OF CONTAMINATION, MEASURED FROM THE OUTER EDGE OF THE PIPE TO THE OUTER EDGE OF THE CONTAMINATION SOURCE UNLESS OTHERWISE SHOWN. 6.ALL STORM SEWER DOWNSPOUT COLLECTION PIPES AND WYES SHALL BE PVC (SCHEDULE 40). 7.CONTRACTOR TO SUBMIT SHOP DRAWINGS OF STORM STRUCTURE(S) AND UNDERGROUND SYSTEM(S) FOR ENGINEER'S REVIEW. 8.CONTRACTOR TO VERIFY UNDERLYING SOILS BENEATH ALL STORMWATER FACILITIES, AND PROVIDE DOCUMENTATION TO THE ENGINEER, PRIOR TO CONSTRUCTION OF THE FACILITIES. 9.ALL PORTIONS OF THE STORM SEWER SYSTEM, INCLUDING CATCH BASINS, LOCATED WITHIN 10 FEET OF THE BUILDING OR WATER SERVICE LINE MUST BE TESTED ACCORDANCE WITH MINNESOTA RULES, PART 4714. ALL JOINTS AND CONNECTIONS SHALL BE GASTIGHT OR WATERTIGHT (SEE MINNESOTA RULES, PART 4714). 10.REFER TO GEOTECHNICAL EVALUATION REPORT AS PREPARED BY BRAUN INTERTEC, FOR AN EXISTING SUBSURFACE SITE CONDITION ANALYSIS AND CONSTRUCTION RECOMMENDATIONS INCLUDING BUT NOT LIMITED TO: A.REUSE OF ON-SITE SOILS B.GROUNDWATER AND RECOMMENDATIONS FOR EXCAVATION DEWATERING. C.SITE GRADING AND SUBGRADE PREPARATION. D.PAVEMENTS AND EXTERIOR SLABS. E.TRENCH EXCAVATION AND BACKFILL. F.EXTERIOR UTILITY SUPPORTS. G.FROST PROTECTION. 11.CONTRACTOR SHALL PROVIDE AS-BUILT INFORMATION OF CONSTRUCTED STORMWATER MANAGEMENT SYSTEMS & ASSOCIATED INFRASTRUCTURE (RECOMMENDED PRIOR TO BACKFILLING) PER APPLICABLE PERMIT REQUIREMENTS AND/OR DEVELOPMENT AGREEMENTS. 12.ALL UNUSED UTILITY SERVICES SHALL BE ABANDONED PER THE REQUIREMENTS OF THE APPLICABLE GOVERNING AGENCIES. 13.THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED UTILITY PERMITS FROM THE APPLICABLE GOVERNING AGENCIES.