Loading...
C4.5 STORM MAIN & POND OUTLET PROFILES444444488888888888888888888888888888888888FES 10 W/ RIP RAP INV=931.10 75 LF-60" RCP @ 0.50% STMH 11 RIM=951.12 INV (E)=938.15 INV (W) = 931.50 199 LF-42" RCP @ 1.25% STMH 12 RIM=951.34 INV=940.64 365 LF-42" RCP @ 1.25% SKIMMER STRUCTURE INLET=952.25 WEIR=951.50 OUTLET=945.20 SEE DETAIL 12" TOP=949.07 12" INV=947.77 42" TOP=946.04 42" INV=941.74 8888AABBCCDD12" TOP=947.30 12" INV=946.00 42" TOP=936.77 42" INV=930.77 930 935 940 945 950 955 960 965 930 935 940 945 950 955 960 965 -1+00 935.8931.41931.10+00 951.00943.8951.52947.31+00 952.40950.7951.90952.32+00 951.36952.6951.90951.13+00 952.61949.5952.58949.54+00 954.29949.8955.95949.95+00 957.76950.6962.20951.36+00 953.84952.27+00 8+00 9+00 199 LF 42" RCP @ 1.25% 365 LF 42" RCP @ 1.25% 75 LF 60" RCP @ 0.53%STMH 11RIM=951.12INV=938.15 (42") EINV=931.50 (60") WSTMH 12RIM=951.10INV=940.64 (42") NEINV=940.64 (42") W12" HDPE 8" PVC C900 WM INV. 945.20 INLET 952.25 SKIMMER OUTLET STRUCTURE (SEE C8.3 FOR DETAILS) 12" PVC 12" PVC INV. 931.10 12" HDPE VERTICAL DEFLECTION TO 13' DEPTH AT PIPE CROSSING 8" PVC 88OCS 51 RIM=945.15 INV(E)=938.0 WEIR= 944.25 ORIFICE(10"Wx8"H)= 943.0 INV(W)=938.0 FES 52 INV=937.44 37 LF-42" RCP @ 1.5% FES 50 W/ RIPRAP INV=932.75 108 LF-42" RCP @ 4.86% WEIR OVERFLOW 10' INV= 946.00 930 935 940 945 950 955 960 930 935 940 945 950 955 960 936.5-0+50 932.73932.70+00 941.14941.1946.50943.01+00 934.87944.8940.79950.52+00 950.52+00 108 L F 4 2" R C P @ 4.8 8 % 37 LF 42" RCP @ 1.50%OCS 51RIM=945.15INV=938.00 (42") NEINV=938.00 (42") SWWEIR=944.2510"X8" ORIFICE=943.00END SECTIONS SHOWN NOT TO SCALE INV. 932.75 INV. 937.44 884444OCS 2 RIM=945.00 INV(E)=936.50 WEIR= 943.00 ORIFICE(9"Wx6"H)= 942.00 INV(W)=934.0 FES 3 INV=936.00 48 LF-30" RCP @ 1.00% FES 1 W/ RIPRAP INV=925.00 116 LF-30" RCP @ 7.76% WEIR OVERFLOW 10' INV= 946.00 88920 925 930 935 940 945 950 955 960 920 925 930 935 940 945 950 955 960 931.3-0+50 925.08925.10+00 939.06939.1946.50946.11+00 940.06953.42+00OCS 2RIM=945.00INV=936.50 (30") EINV=934.00 (30") NWWEIR=943.09"WX6"H ORIFICE=942.00END SECTIONS SHOWN NOT TO SCALE INV. 925.00 INV. 936.00 48 LF 30" RCP @ 1.04% 116 LF 30" R C P @ 7.79 % (A) 910 920 930 940 950 960 970 910 920 930 940 950 960 970 50 40 30 20 10 944.3℄951.0710 20 30 40 50 SEWER ESMT 1:1 SLOPE PIPE TRENCH SEWER ESMT INV 930.65 (B) 910 920 930 940 950 960 970 910 920 930 940 950 960 970 50 40 30 20 10 950.7℄952.4010 20 30 40 50 1:1 SLOPE PIPE TRENCH SEWER ESMT SEWER ESMT 72" SOLID CMP REUSE TANK INV 943.50 INV 938.50 34.0' FUELING STATION (C) 910 920 930 940 950 960 970 910 920 930 940 950 960 970 50 40 30 20 10 949.5℄952.6110 20 30 40 50 1:1 SLOPE PIPE TRENCH SEWER ESMT SEWER ESMT INV 941.00 (D) 920 930 940 950 960 970 980 920 930 940 950 960 970 980 50 40 30 20 10 950.6℄957.7610 20 30 40 50 1:1 SLOPE PIPE TRENCH SEWER ESMT SEWER ESMT INV 943.50 N SCALE IN FEET 0 50 100 NORTH KEY PLAN DRAWING NUMBER DRAWING TITLE CLIENT 4201 cedar avenue so. - minneapolis, MN 55407 tel. (612) 904-1332 - fax (612) 904-7366 NOT F O R C O N S T R U C TI O N PROJECT NUMBER 21602.0A REVISION DATE DESCRIPTION BY 1891 Arboretum Boulevard Chanhassen, MN 55317 Xcel Energy Service Center Chanhassen Title: Zachary B. Moen - PE Registration Number: 58688 Date: XX/XX/XXXX By: Title: Professional Engineer I hereby certify that this drawing was prepared by me or under my direct supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota. LOUCKS PROJECT NO. 21602 10/25/2022 WATERSHED SUBMITTAL 11/16/2022 TEP SUBMITTAL 11/16/2022 SCHEMATIC DESIGN PACKAGE 12/05/2022 SD PACKAGE ADDENDUM 01/12/2023 CITY SUBMISSION C4.5 STORM MAIN & POND OUTLET PROFILES NOTE: EXISTING CONDITIONS INFORMATION SHOWN IS FROM AN ALTA/NSPS LAND TITLE SURVEY PREPARED BY LOUCKS, DATED 03/24/2022. PARKING STALL COUNT ACCESSIBLE PARKING STALL 2 LEGEND CATCH BASIN STORM SEWER SANITARY SEWER WATERMAIN STORM MANHOLE SANITARY MANHOLE HYDRANT GATE VALVE SPOT ELEVATION SIGN LIGHT POLE POWER POLE WATER MANHOLE / WELL CONTOUR CONCRETE CURB UNDERGROUND ELECTRIC CONCRETE TELEPHONE PEDESTAL UNDERGROUND TELEPHONE UNDERGROUND GAS OVERHEAD UTILITY CHAIN LINK FENCE BUILDING RETAINING WALL NO PARKING UNDERGROUND FIBER OPTIC SANITARY SEWER SERVICE WATER SERVICE ELECTRIC METER GAS METER TREE LINE EXISTING PROPOSED 972 DRAINTILE FORCEMAIN 373PARKING SETBACK LINE BUILDING SETBACK LINE 2 FENCE FLARED END SECTION POST INDICATOR VALVE BENCHMARK SOIL BORING 3DIRECTION OF FLOW 1.0% 972.5 Gopher State One Call WARNING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. SANITARY SEWER & WATERMAIN NOTES 1.ALL SANITARY SEWER AND WATERMAIN UTILITIES SHALL BE FURNISHED AND INSTALLED PER THE REQUIREMENTS OF THE SPECIFICATIONS,THE MINNESOTA PLUMBING CODE, THE LOCAL GOVERNING UNIT, AND THE STANDARD UTILITIES SPECIFICATION OF THE CITY ENGINEERS ASSOCIATION OF MINNESOTA (CEAM), CURRENT EDITION. 2.ALL UTILITY PIPE BEDDING SHALL BE COMPACTED SAND OR FINE GRANULAR MATERIAL. ALL COMPACTION SHALL BE PERFORMED PER THE REQUIREMENTS OF THE CEAM SPECIFICATION AND THE GEOTECHNICAL REPORT. 3.ALL CONNECTIONS TO EXISTING UTILITIES SHALL BE PERFORMED PER THE REQUIREMENTS OF THE STATE AND LOCAL JURISDICTIONS. THE CITY DEPARTMENT OF ENGINEERING AND BUILDING INSPECTIONS DEPARTMENT AND THE CONSTRUCTION ENGINEER MUST BE NOTIFIED AT LEAST 48 HOURS PRIOR TO ANY WORK WITHIN THE PUBLIC RIGHT OF WAY, OR WORK IMPACTING PUBLIC UTILITIES. 4.ALL SITE UTILITY SERVICES SHALL TERMINATE 5' FROM THE EXTERIOR BUILDING WALL UNLESS OTHERWISE NOTED. THE SITE UTILITY CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR, MECHANICAL CONTRACTOR AND MECHANICAL ENGINEER TO DETERMINE THE RESPONSIBILITY OF BRINGING THE SERVICE(S) INTO THE BUILDING, INSPECTIONS AND TESTING PER APPLICABLE GOVERNING AGENCIES. 5.ALL NEW WATERMAIN AND SERVICES MUST HAVE A MINIMUM OF 7.5 FEET OF COVER. EXTRA DEPTH MAY BE REQUIRED TO MAINTAIN A MINIMUM 18" VERTICAL SEPARATION TO SANITARY OR STORM SEWER LINES. THE CONTRACTOR SHALL FIELD ADJUST WATERMAIN TO AVOID CONFLICTS WITH SANITARY SEWER, STORM SEWER, AND SERVICES AS REQUIRED. INSULATION OF WATERMAIN AND SANITARY SEWER LINES SHALL BE PROVIDED WHERE 7.5 FEET MINIMUM DEPTH CAN NOT BE ATTAINED. 6.PER MINNESOTA DEPARTMENT OF LABOR & INDUSTRY REQUIREMENTS, A MINIMUM OF 18 INCHES OF VERTICAL SEPARATION AND 10 FEET OF HORIZONTAL SEPARATION IS REQUIRED FROM WATERMAIN TO ANY MANHOLE, SEPTIC SYSTEM, CATCH BASIN, SEWER PIPE, OR OTHER SOURCE OF CONTAMINATION, MEASURED FROM THE OUTER EDGE OF THE PIPE TO THE OUTER EDGE OF THE CONTAMINATION SOURCE UNLESS OTHERWISE SHOWN. 7.CONTRACTOR TO SUBMIT SHOP DRAWINGS OF SANITARY STRUCTURE(S) AND UNDERGROUND SYSTEM(S) FOR ENGINEER'S REVIEW. 8.ALL FIRE HYDRANTS SHALL BE LOCATED 5 FEET BEHIND BACK OF CURB OR EDGE OF PAVEMENT UNLESS OTHERWISE NOTED. 9.REFER TO GEOTECHNICAL EVALUATION REPORT AS PREPARED BY BRAUN INTERTEC, FOR AN EXISTING SUBSURFACE SITE CONDITION ANALYSIS AND CONSTRUCTION RECOMMENDATIONS INCLUDING BUT NOT LIMITED TO: A.REUSE OF ON-SITE SOILS B.GROUNDWATER AND RECOMMENDATIONS FOR EXCAVATION DEWATERING. C.SITE GRADING AND SUBGRADE PREPARATION. D.PAVEMENTS AND EXTERIOR SLABS. E.TRENCH EXCAVATION AND BACKFILL. F.EXTERIOR UTILITY SUPPORTS. G.FROST PROTECTION. 10.CONTRACTOR SHALL PROVIDE AS-BUILT INFORMATION OF CONSTRUCTED UTILITIES (RECOMMENDED PRIOR TO BACKFILLING) PER APPLICABLE PERMIT REQUIREMENTS AND/OR DEVELOPMENT AGREEMENTS. 11.ALL UNUSED UTILITY SERVICES SHALL BE ABANDONED PER THE REQUIREMENTS OF THE APPLICABLE GOVERNING AGENCIES. 12.THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED UTILITY PERMITS FROM THE APPLICABLE GOVERNING AGENCIES. STORM SEWER NOTES 1.ALL STORM SEWER SHALL BE FURNISHED AND INSTALLED PER THE REQUIREMENTS OF THE SPECIFICATIONS,THE MINNESOTA PLUMBING CODE, THE LOCAL GOVERNING UNIT, AND THE STANDARD UTILITIES SPECIFICATION OF THE CITY ENGINEERS ASSOCIATION OF MINNESOTA (CEAM), CURRENT EDITION. 2.ALL UTILITY PIPE BEDDING SHALL BE COMPACTED SAND OR FINE GRANULAR MATERIAL. ALL COMPACTION SHALL BE PERFORMED PER THE REQUIREMENTS OF THE CEAM SPECIFICATION AND THE GEOTECHNICAL REPORT. 3.ALL CONNECTIONS TO EXISTING UTILITIES SHALL BE PERFORMED PER THE REQUIREMENTS OF THE STATE AND LOCAL JURISDICTIONS. THE CITY DEPARTMENT OF ENGINEERING AND BUILDING INSPECTIONS DEPARTMENT AND THE CONSTRUCTION ENGINEER MUST BE NOTIFIED AT LEAST 48 HOURS PRIOR TO ANY WORK WITHIN THE PUBLIC RIGHT OF WAY, OR WORK IMPACTING PUBLIC UTILITIES. 4.ALL SITE UTILITY SERVICES SHALL TERMINATE 5' FROM THE EXTERIOR BUILDING WALL UNLESS OTHERWISE NOTED. THE SITE UTILITY CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR, MECHANICAL CONTRACTOR AND MECHANICAL ENGINEER TO DETERMINE THE RESPONSIBILITY OF BRINGING THE SERVICE(S) INTO THE BUILDING, INSPECTIONS AND TESTING PER APPLICABLE GOVERNING AGENCIES. 5.PER MINNESOTA DEPARTMENT OF LABOR & INDUSTRY REQUIREMENTS, A MINIMUM OF 18 INCHES OF VERTICAL SEPARATION AND 10 FEET OF HORIZONTAL SEPARATION IS REQUIRED FROM WATERMAIN TO ANY MANHOLE, SEPTIC SYSTEM, CATCH BASIN, SEWER PIPE, OR OTHER SOURCE OF CONTAMINATION, MEASURED FROM THE OUTER EDGE OF THE PIPE TO THE OUTER EDGE OF THE CONTAMINATION SOURCE UNLESS OTHERWISE SHOWN. 6.ALL STORM SEWER DOWNSPOUT COLLECTION PIPES AND WYES SHALL BE PVC (SCHEDULE 40). 7.CONTRACTOR TO SUBMIT SHOP DRAWINGS OF STORM STRUCTURE(S) AND UNDERGROUND SYSTEM(S) FOR ENGINEER'S REVIEW. 8.CONTRACTOR TO VERIFY UNDERLYING SOILS BENEATH ALL STORMWATER FACILITIES, AND PROVIDE DOCUMENTATION TO THE ENGINEER, PRIOR TO CONSTRUCTION OF THE FACILITIES. 9.ALL PORTIONS OF THE STORM SEWER SYSTEM, INCLUDING CATCH BASINS, LOCATED WITHIN 10 FEET OF THE BUILDING OR WATER SERVICE LINE MUST BE TESTED ACCORDANCE WITH MINNESOTA RULES, PART 4714. ALL JOINTS AND CONNECTIONS SHALL BE GASTIGHT OR WATERTIGHT (SEE MINNESOTA RULES, PART 4714). 10.REFER TO GEOTECHNICAL EVALUATION REPORT AS PREPARED BY BRAUN INTERTEC, FOR AN EXISTING SUBSURFACE SITE CONDITION ANALYSIS AND CONSTRUCTION RECOMMENDATIONS INCLUDING BUT NOT LIMITED TO: A.REUSE OF ON-SITE SOILS B.GROUNDWATER AND RECOMMENDATIONS FOR EXCAVATION DEWATERING. C.SITE GRADING AND SUBGRADE PREPARATION. D.PAVEMENTS AND EXTERIOR SLABS. E.TRENCH EXCAVATION AND BACKFILL. F.EXTERIOR UTILITY SUPPORTS. G.FROST PROTECTION. 11.CONTRACTOR SHALL PROVIDE AS-BUILT INFORMATION OF CONSTRUCTED STORMWATER MANAGEMENT SYSTEMS & ASSOCIATED INFRASTRUCTURE (RECOMMENDED PRIOR TO BACKFILLING) PER APPLICABLE PERMIT REQUIREMENTS AND/OR DEVELOPMENT AGREEMENTS. 12.ALL UNUSED UTILITY SERVICES SHALL BE ABANDONED PER THE REQUIREMENTS OF THE APPLICABLE GOVERNING AGENCIES. 13.THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED UTILITY PERMITS FROM THE APPLICABLE GOVERNING AGENCIES. SOUTH POND OUTLETNORTH POND OUTLET STORM MAINLINE N N STORM MAINLINE CROSS SECTIONS