C4.7 FOUNDATION DRAINTILE NORTH3506 5 STC 3 0 " R C P 945. 1 5 3506 8 STC 1 2 " R C P 944. 0 3 4444444448888888888888888888888888888888888888888888888888888 NOPARKINGNO PARKING NO PARKING PROPOSED BUILDING LOWER LEVEL=952.50 LEVEL 1=974.50 COLD STORAGE BUILDING FFE=952.50 8 8 888888888CONNECT TO CBMH 61 @ INV=946.75 (2)-8" CLEANOUT W/ CAST IRON FRAME & COVER RIM=957.95± INV=949.00± TYP-SEE DETAIL 8" CLEANOUT W/ CAST IRON FRAME & COVER RIM=960.95± INV=949.00± TYP-SEE DETAIL 8" CLEANOUT W/ CAST IRON FRAME & COVER RIM=952.70± INV=949.00± TYP-SEE DETAIL 275 LF-6" PVC DRAINTILE INV=949.00± DT INV=949.00± 111 LF-6" SOLID PVC @ 2.0% 670 LF-6" PVC DRAINTILE INV=949.00± 775 LF-6" PVC DRAINTILE INV=949.00± 8" CLEANOUT W/ CAST IRON FRAME & COVER RIM=952.45± INV=949.00± TYP-SEE DETAIL 8" CLEANOUT W/ CAST IRON FRAME & COVER RIM=952.45± INV=949.00± TYP-SEE DETAIL 8" CLEANOUT W/ CAST IRON FRAME & COVER RIM=952.45± INV=949.00± TYP-SEE DETAIL 8" CLEANOUT W/ CAST IRON FRAME & COVER RIM=952.45± INV=949.00± TYP-SEE DETAIL 8" CLEANOUT W/ CAST IRON FRAME & COVER RIM=952.45± INV=949.00± TYP-SEE DETAIL 8" CLEANOUT W/ CAST IRON FRAME & COVER RIM=952.45± INV=949.00± TYP-SEE DETAIL 8" CLEANOUT W/ CAST IRON FRAME & COVER RIM=974.45± INV=949.00± TYP-SEE DETAIL 8" CLEANOUT W/ CAST IRON FRAME & COVER RIM=974.45± INV=949.00± TYP-SEE DETAIL 8" CLEANOUT W/ CAST IRON FRAME & COVER RIM=964.95± INV=949.00± TYP-SEE DETAIL N SCALE IN FEET 0 30 60 NORTH KEY PLAN DRAWING NUMBER DRAWING TITLE CLIENT 4201 cedar avenue so. - minneapolis, MN 55407 tel. (612) 904-1332 - fax (612) 904-7366 NOT F O R C O N S T R U C TI O N PROJECT NUMBER 21602.0A REVISION DATE DESCRIPTION BY 1891 Arboretum Boulevard Chanhassen, MN 55317 Xcel Energy Service Center Chanhassen Title: Zachary B. Moen - PE Registration Number: 58688 Date: XX/XX/XXXX By: Title: Professional Engineer I hereby certify that this drawing was prepared by me or under my direct supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota. LOUCKS PROJECT NO. 21602 10/25/2022 WATERSHED SUBMITTAL 11/16/2022 TEP SUBMITTAL 11/16/2022 SCHEMATIC DESIGN PACKAGE 12/05/2022 SD PACKAGE ADDENDUM 01/12/2023 CITY SUBMISSION C4.7 FOUNDATION DRAINTILE NORTH NOTE: EXISTING CONDITIONS INFORMATION SHOWN IS FROM AN ALTA/NSPS LAND TITLE SURVEY PREPARED BY LOUCKS, DATED 03/24/2022. PARKING STALL COUNT ACCESSIBLE PARKING STALL 2 LEGEND CATCH BASIN STORM SEWER SANITARY SEWER WATERMAIN STORM MANHOLE SANITARY MANHOLE HYDRANT GATE VALVE SPOT ELEVATION SIGN LIGHT POLE POWER POLE WATER MANHOLE / WELL CONTOUR CONCRETE CURB UNDERGROUND ELECTRIC CONCRETE TELEPHONE PEDESTAL UNDERGROUND TELEPHONE UNDERGROUND GAS OVERHEAD UTILITY CHAIN LINK FENCE BUILDING RETAINING WALL NO PARKING UNDERGROUND FIBER OPTIC SANITARY SEWER SERVICE WATER SERVICE ELECTRIC METER GAS METER TREE LINE EXISTING PROPOSED 972 DRAINTILE FORCEMAIN 373PARKING SETBACK LINE BUILDING SETBACK LINE 2 FENCE FLARED END SECTION POST INDICATOR VALVE BENCHMARK SOIL BORING 3DIRECTION OF FLOW 1.0% 972.5 Gopher State One Call WARNING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. STORM SEWER NOTES 1.ALL STORM SEWER SHALL BE FURNISHED AND INSTALLED PER THE REQUIREMENTS OF THE SPECIFICATIONS,THE MINNESOTA PLUMBING CODE, THE LOCAL GOVERNING UNIT, AND THE STANDARD UTILITIES SPECIFICATION OF THE CITY ENGINEERS ASSOCIATION OF MINNESOTA (CEAM), CURRENT EDITION. 2.ALL UTILITY PIPE BEDDING SHALL BE COMPACTED SAND OR FINE GRANULAR MATERIAL. ALL COMPACTION SHALL BE PERFORMED PER THE REQUIREMENTS OF THE CEAM SPECIFICATION AND THE GEOTECHNICAL REPORT. 3.ALL CONNECTIONS TO EXISTING UTILITIES SHALL BE PERFORMED PER THE REQUIREMENTS OF THE STATE AND LOCAL JURISDICTIONS. THE CITY DEPARTMENT OF ENGINEERING AND BUILDING INSPECTIONS DEPARTMENT AND THE CONSTRUCTION ENGINEER MUST BE NOTIFIED AT LEAST 48 HOURS PRIOR TO ANY WORK WITHIN THE PUBLIC RIGHT OF WAY, OR WORK IMPACTING PUBLIC UTILITIES. 4.ALL SITE UTILITY SERVICES SHALL TERMINATE 5' FROM THE EXTERIOR BUILDING WALL UNLESS OTHERWISE NOTED. THE SITE UTILITY CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR, MECHANICAL CONTRACTOR AND MECHANICAL ENGINEER TO DETERMINE THE RESPONSIBILITY OF BRINGING THE SERVICE(S) INTO THE BUILDING, INSPECTIONS AND TESTING PER APPLICABLE GOVERNING AGENCIES. 5.PER MINNESOTA DEPARTMENT OF LABOR & INDUSTRY REQUIREMENTS, A MINIMUM OF 18 INCHES OF VERTICAL SEPARATION AND 10 FEET OF HORIZONTAL SEPARATION IS REQUIRED FROM WATERMAIN TO ANY MANHOLE, SEPTIC SYSTEM, CATCH BASIN, SEWER PIPE, OR OTHER SOURCE OF CONTAMINATION, MEASURED FROM THE OUTER EDGE OF THE PIPE TO THE OUTER EDGE OF THE CONTAMINATION SOURCE UNLESS OTHERWISE SHOWN. 6.ALL STORM SEWER DOWNSPOUT COLLECTION PIPES AND WYES SHALL BE PVC (SCHEDULE 40). 7.CONTRACTOR TO SUBMIT SHOP DRAWINGS OF STORM STRUCTURE(S) AND UNDERGROUND SYSTEM(S) FOR ENGINEER'S REVIEW. 8.CONTRACTOR TO VERIFY UNDERLYING SOILS BENEATH ALL STORMWATER FACILITIES, AND PROVIDE DOCUMENTATION TO THE ENGINEER, PRIOR TO CONSTRUCTION OF THE FACILITIES. 9.ALL PORTIONS OF THE STORM SEWER SYSTEM, INCLUDING CATCH BASINS, LOCATED WITHIN 10 FEET OF THE BUILDING OR WATER SERVICE LINE MUST BE TESTED ACCORDANCE WITH MINNESOTA RULES, PART 4714. ALL JOINTS AND CONNECTIONS SHALL BE GASTIGHT OR WATERTIGHT (SEE MINNESOTA RULES, PART 4714). 10.REFER TO GEOTECHNICAL EVALUATION REPORT AS PREPARED BY BRAUN INTERTEC, FOR AN EXISTING SUBSURFACE SITE CONDITION ANALYSIS AND CONSTRUCTION RECOMMENDATIONS INCLUDING BUT NOT LIMITED TO: A.REUSE OF ON-SITE SOILS B.GROUNDWATER AND RECOMMENDATIONS FOR EXCAVATION DEWATERING. C.SITE GRADING AND SUBGRADE PREPARATION. D.PAVEMENTS AND EXTERIOR SLABS. E.TRENCH EXCAVATION AND BACKFILL. F.EXTERIOR UTILITY SUPPORTS. G.FROST PROTECTION. 11.CONTRACTOR SHALL PROVIDE AS-BUILT INFORMATION OF CONSTRUCTED STORMWATER MANAGEMENT SYSTEMS & ASSOCIATED INFRASTRUCTURE (RECOMMENDED PRIOR TO BACKFILLING) PER APPLICABLE PERMIT REQUIREMENTS AND/OR DEVELOPMENT AGREEMENTS. 12.ALL UNUSED UTILITY SERVICES SHALL BE ABANDONED PER THE REQUIREMENTS OF THE APPLICABLE GOVERNING AGENCIES. 13.THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED UTILITY PERMITS FROM THE APPLICABLE GOVERNING AGENCIES. NOTES: CAST IRON CASTING REQUIRED. SEE SPECIFICATIONS. END OF LINE CLEANOUT IN LINE CLEANOUT PVC LONG SWEEP BEND SCH. 80 VARIES VARIES ONE PIECE 8" PVC SCH. 80 CLEANOUT RISER DRAINTILE CLEAN-OUT STRUCTURE DRAWN 2/2016 LOUCKS PLATE NO. 4315LOUCKS PVC WYE SCH. 80 DRAWN 3/2018 LOUCKS PLATE NO. EXTERIOR FOUNDATION DRAINTILE DETAIL NOT TO SCALE NOTE 1.SEE MECHANICAL PLANS FOR FOUNDATION DRAINTILE ON INTERIOR OF BUILDING. 2.COORDINATE W/ WALL SUPPLIER FOR SLEEVES THROUGH SITE WALLS. 3.NON-WOVEN GEOTECHNICAL FABRIC SHALL BE PLACED AROUND THE ENTIRE DRAINAGE AGGREGATE FIELD. FULLY ADHERE SEAMS AND CINCH WITH A STAINLESS STEEL RING CLAMP AT CLEANOUT LOCATIONS. PIPE DETAIL 160° 90° 1 4" DIA. HOLE TYPICAL TRENCH DETAIL 2" MIN. 5" MIN. 6" MIN. FINISHED FLOOR ELEVATION APPROVED FREE DRAINING BACKFILL MATERIAL (SEE SPECS) COARSE FILTER AGGREGATE MNDOT 3149.2H THE AGGREGATE SHALL BE ROUND RIVER ROCK, WASHED AND FREE OF FINE PARTICLES NON-WOVEN GEOTEXTILE FABRIC AROUND DRAINAGE ROCK - MNDOT 3733, TYPE 1 FOUNDATION (SEE STRUCTURAL) 6" PERFORATED SCHEDULE 80 PVC PIPE 5" FROM EDGE OF DRAINTILE TO FACE OF FOUNDATION WALL TO ALLOW FOR PLACEMENT OF INSULATION APPROVED FREE DRAINING BACKFILL MATERIAL (SEE SPECS) DRAWN 3/2018 LOUCKS PLATE NO.EXTERIOR FOUNDATION DRAINTILE DETAIL DROPPED FOOTING LOCATIONS NOT TO SCALE 2" MIN. 5" MIN. 6" MIN. FINISHED FLOOR ELEVATION APPROVED FREE DRAINING BACKFILL MATERIAL (SEE SPECS) COARSE FILTER AGGREGATE MNDOT 3149.2H THE AGGREGATE SHALL BE ROUND RIVER ROCK, WASHED AND FREE OF FINE PARTICLES NON-WOVEN GEOTEXTILE FABRIC AROUND DRAINAGE ROCK - MNDOT 3733, TYPE 1 FOUNDATION (SEE STRUCTURAL) 6" PERFORATED SCHEDULE 80 PVC PIPE 5" FROM EDGE OF DRAINTILE TO FACE OF FOUNDATION WALL TO ALLOW FOR PLACEMENT OF INSULATION INV=949.00 NOTE 1.SEE MECHANICAL DRAWINGS FOR FOUNDATION DRAINTILE ON INTERIOR OF BUILDING. 2.NON-WOVEN GEOTECHNICAL FABRIC SHALL BE PLACED AROUND THE ENTIRE DRAINAGE AGGREGATE FIELD. FULLY ADHERE SEAMS AND CINCH WITH A STAINLESS STEEL RING CLAMP AT CLEANOUT LOCATIONS. PIPE DETAIL 160° 90° 1 4" DIA. HOLE TYPICAL TRENCH DETAIL APPROVED FREE DRAINING BACKFILL MATERIAL (SEE SPECS)