CAS-19_AMERICAN TOWER CORPORATION CUP AMENDMENT (90-3) (2)Document No. OFFICE OF THE
COUNTYRECORDER
A 515383 CARVER COUNTY, MINNESOTA
Fee $46 00 Receipt#
Certified Recorded on 2/22/2010 at 01:15 ❑ AM
IlRlll�lm
CITY OF CHANHASSEN
CARVER AND HENNEPIN COUNTIES, MINNESOTA
AMENDED AND RESTATED
CONDITIONAL USE PERMIT #90-3
PLANNING CASE #09-19
1. Permit. Subject to the terns and conditions set forth herein, the City of Chanhassen
hereby grants an amended and restated conditional use permit for the following use which replaces
Conditional Use Permit 90-3:
A Conditional Use Permit for a 115 -foot tall, telecommunication tower
2. Property. The permit is for property situated in the City of Chanhassen, Carver County,
Minnesota, and legally described as Outlot B, Stone Creek First Addition.
3. Conditions. The permit is issued to American Tower Company and Merle and Jane
Volk subject to the following conditions:
a. The tower and antennas shall comply with the requirements in Chapter 20, Article
XXX, Towers and Antennas of the Chanhassen City Code.
b. A building permit is required for equipment pad and LP gas storage tank pad.
c. A mechanical permit is required for connection (gas piping) of LP storage tank to LP
gas generator.
d. The plans must be signed by appropriate design professionals.
1
SCANNED
e. No signage, advertising or identification of any kind intended to be visible from the
ground or other structures is permitted, except applicable warning and equipment
information signage required by the manufacturer or by Federal, State, or local
authorities.
4. Severability. In the event any provision of this permit shall be held invalid, illegal, or
unenforceable by any court or competent jurisdiction, such holding shall not invalidate or render
unenforceable any other provision hereof, and the remaining provisions shall not in any way be
affected or impaired thereby.
5. Notices. All notices, certificates and other communications hereunder shall be
sufficiently given and shall be deemed given when mailed by certified mail, returned receipt
requested, postage prepaid, with property address as indicated below. The City and the
Association, by written notice given by one to the other, may designate any address or addresses,
to be sent when required as contemplated by this permit. Unless otherwise provided by the
respective parties, all notices, certificates, and communications to each of them shall be
addressed as follows:
To the City: City of Chanhassen
Attn: City Manager
7700 Market Boulevard
P.O. Box 147
Chanhassen, MN 55317
To the Applicant: American Tower
Attn: Doug Ruwe
21307 Rio Oro Drive
Cornelius, NC 28031
To the Owner: Merle and Jane Volk
16925 County Road 40
Carver, MN 55315
6. Reimbursement of Costs. The Applicant shall reimburse the City for all costs,
including reasonable engineering, legal, planning and administrative expenses incurred by the
City in connection with all matters relating to the administration and enforcement of the within
permit and the performance thereby by the applicant. Such reimbursement shall be made within
fourteen (14) days of the date of mailing of the City's notice of costs as provided in Section 5
above. This reimbursement obligation of the applicant under this section shall be a continuing
obligation throughout the term of this permit.
7. Termination of Permit. The City may revoke the permit following a public hearing for
violation of the terms of this permit. The City may institute any proper action or proceeding at
law or at equity to prevent violations of the within property, to restrain or abate violations of the
within permit, or to prevent use or occupancy of the Subject Property.
8. Lapse. If within one year of the issuance of this permit the authorized construction has
not been substantially completed or the use commenced, this permit shall lapse, unless an extension
is granted in accordance with the Chanhassen Zoning Ordinance.
9. Assignable. This conditional use permit is issued for the particular use and is not
personal. The City shall be notified in writing at the address provided in section 5 above of any
changes in the leasehold interest or ownership of the underlying property at least thirty (30) days
prior to such change.
10. Criminal Penalty. Violation of the terns of this conditional use permit is a criminal
misdemeanor.
Dated: December 14, 2009
CITY OF CHANHASSEN
BY: mak-
Tom Furlong, Mayor
(SEAL)
Gerhardt, City Manager
STATE OF MINNESOTA )
(ss
COUNTY OF CARVER )
The foregoing instrument was acknowledged before me this I fhday of bec---m fe 200 9,
by Thomas A. Furlong, Mayor, and by Todd Gerhardt, City Manager, of the City of Chanhassen, a
Minnesota municipal corporation, on behalf of the corporation and pursuant to the authority granted
by its City Council.
NOTARY PUBIIC
DRAFTED BY:
City of Chanhassen
P. O. Box 147
7700 Market Boulevard
Chanhassen, MN 55317
(952)227-1100
e YIM T. MEUWISSEN
S fi r; NOlef`i �'11bIIC VeMsIJ nta
3S020,0
�% My commission Exp
R
CITY OF CHANHASSEN
CARVER AND HENNEPIN COUNTIES, MINNESOTA
FINDINGS OF FACT
AND RECOMMENDATION
Il rIT3
Application of American Tower and Merle and Jane Volk for an amendment to the existing
Conditional Use Permit 90-3 to permit the installation of additional antennas and equipment at
and upon an existing telecommunication tower.
On December 1, 2009, the Chanhassen Planning Commission met at its regularly
scheduled meeting to consider the application of American Tower and Merle and Jane Volk for
an amendment to a conditional use permit to permit a telecommunication tower for the property
located at 2290 Lyman Boulevard. The Planning Commission conducted a public hearing on the
proposed conditional use was preceded by published and mailed notice. The Planning
Commission heard testimony from all interested persons wishing to speak and now makes the
following:
FINDINGS OF FACT
The property is currently zoned Agricultural Estate District, A-2.
2. The property is guided by the Land Use Plan for Residential — Low Density.
3. The legal description of the property is: Outlot B, Stone Creek First Addition.
4. Conditional Use Permits
a. The proposed use will not be detrimental to, but may enhance the public health,
safety, comfort, convenience or general welfare of the neighborhood or the city. The
proposed tower will provide a basic utility to the area.
b. The proposed use will be consistent with the objectives of the city's comprehensive
plan and this chapter.
c. The proposed use will be designed, constructed, operated and maintained so to be
compatible in appearance with the existing or intended character of the general
vicinity and will not change the essential character of that area. The proposed tower
complies with city ordinance requirements. The lower portion of the tower including
the equipment will be screened by vegetation and a berm.
d. The proposed use will not be hazardous or disturbing to existing or planned
neighboring uses.
SCANNED
e. The proposed use will be served adequately by essential public facilities and services,
including streets, police and fire protection, drainage structures, refuse disposal, water
and sewer systems and schools; or will be served adequately by such facilities and
services provided by the persons or agencies responsible for the establishment of the
proposed use.
The proposed use will not create excessive requirements for public facilities and
services and will not be detrimental to the economic welfare of the community. It
will provide a necessary utility.
g. The proposed use will not involve uses, activities, processes, materials, equipment
and conditions of operation that will be detrimental to any persons, property or the
general welfare because of excessive production of traffic, noise, smoke, fumes, glare,
odors, rodents, or trash. The tower should not create conditions that are detrimental
to person's property or the general welfare of the community.
h. The proposed use will have vehicular approaches to the property which do not create
traffic congestion or interfere with traffic or surrounding public thoroughfares.
The proposed use will not result in the destruction, loss or damage of solar access,
natural, scenic or historic features of major significance.
j. The proposed use will be aesthetically compatible with the area.
k. The proposed use will not depreciate surrounding property values.
1. The proposed use will meet standards prescribed for communication towers as
provided in zoning ordinance.
5. The Planning Report #09-19 dated December 1, 2009, prepared by Robert Generous, et
al, is incorporated herein.
The Planning Commission recommends that the City Council approve the amendment to
the conditional use permit for a telecommunication tower.
ADOPTED by the Chanhassen Planning Commission this I' day of December, 2009.
CITY OF CHANHASSEN
PLANNING DEPARTMENT
7700 Market Boulevard
P.O. Box 147
CHANHASSEN, MN 55317
(952) 227-1100 FAX (952) 227-1110
TO: Campbell Knutson, PA
317 Eagandale Office Center
1380 Corporate Center Curve
Eagan, MN 55121
LETTER OF TRANSMITTAL
DATE JOB NO.
12/17/09 09-19
ATTENTION
Sue Nelson
RE:
Document Recording
WE ARE SENDING YOU ® Attached ❑ Under separate cover via the following items:
❑
Shop drawings
❑
Prints
❑
Plans ❑
Samples ❑ Specifications
❑
Copy of letter
❑
Change Order
❑
Pay Request
❑
COPIES
DATE
NO.
DESCRIPTION
1
12/14/09
09-19
Amended and Restated Conditional Use Permit 490-3 for 115 -foot
telecommunication tower - Outlot B, Stone Creek First Addition
❑
FOR BIDS DUE
For Recording
❑
PRINTS RETURNED AFTER
LOAN TO US
THESE ARE TRANSMITTED as checked below:
❑
For approval
❑
For your use
❑
As requested
❑
For review and comment
❑
FOR BIDS DUE
REMARKS
❑
Approved as submitted
❑ Resubmit
❑
Approved as noted
❑ Submit
❑
Returned for corrections
❑ Return
®
For Recording
❑
PRINTS RETURNED AFTER
LOAN TO US
COPY TO: Mr. Doug Ruwe, American Tower Corporation
Merle and Jane Volk
copies for approval
copies for distribution
corrected prints
SCANNED
If enclosures are not as noted, kindly notify us at once.
CITY OF CHANHASSEN
CARVER AND HENNEPIN COUNTIES, MINNESOTA
AMENDED AND RESTATED
CONDITIONAL USE PERMIT #90-3
PLANNING CASE #09-19
1. Permit. Subject to the terms and conditions set forth herein, the City of Chanhassen
hereby grants an amended and restated conditional use permit for the following use which replaces
Conditional Use Permit 90-3:
A Conditional Use Permit for a 115 -foot tall, telecommunication tower
2. Property. The permit is for property situated in the City of Chanhassen, Carver County,
Minnesota, and legally described as Outlot B, Stone Creek First Addition.
3. Conditions. The permit is issued to American Tower Company and Merle and Jane
Volk subject to the following conditions:
a. The tower and antennas shall comply with the requirements in Chapter 20, Article
XXX, Towers and Antennas of the Chanhassen City Code.
b. A building permit is required for equipment pad and LP gas storage tank pad.
c. A mechanical permit is required for connection (gas piping) of LP storage tank to LP
gas generator.
d. The plans must be signed by appropriate design professionals.
e. No signage, advertising or identification of any kind intended to be visible from the
ground or other structures is permitted, except applicable warning and equipment
information signage required by the manufacturer or by Federal, State, or local
authorities.
4. Severability. In the event any provision of this permit shall be held invalid, illegal, or
unenforceable by any court or competent jurisdiction, such holding shall not invalidate or render
unenforceable any other provision hereof, and the remaining provisions shall not in any way be
affected or impaired thereby.
5. Notices. All notices, certificates and other communications hereunder shall be
sufficiently given and shall be deemed given when mailed by certified mail, returned receipt
requested, postage prepaid, with property address as indicated below. The City and the
Association, by written notice given by one to the other, may designate any address or addresses,
to be sent when required as contemplated by this permit. Unless otherwise provided by the
respective parties, all notices, certificates, and communications to each of them shall be
addressed as follows:
To the City: City of Chanhassen
Attn: City Manager
7700 Market Boulevard
P.O. Box 147
Chanhassen, MN 55317
To the Applicant: American Tower
Attn: Doug Ruwe
21307 Rio Oro Drive
Cornelius, NC 28031
To the Owner: Merle and Jane Volk
16925 County Road 40
Carver, MN 55315
6. Reimbursement of Costs. The Applicant shall reimburse the City for all costs,
including reasonable engineering, legal, planning and administrative expenses incurred by the
City in connection with all matters relating to the administration and enforcement of the within
permit and the performance thereby by the applicant. Such reimbursement shall be made within
fourteen (14) days of the date of mailing of the City's notice of costs as provided in Section 5
above. This reimbursement obligation of the applicant under this section shall be a continuing
obligation throughout the term of this permit.
7. Termination of Permit. The City may revoke the permit following a public hearing for
violation of the terms of this permit. The City may institute any proper action or proceeding at
law or at equity to prevent violations of the within property, to restrain or abate violations of the
within permit, or to prevent use or occupancy of the Subject Property.
2
8. Lapse. If within one year of the issuance of this permit the authorized construction has
not been substantially completed or the use commenced, this permit shall lapse, unless an extension
is granted in accordance with the Chanhassen Zoning Ordinance.
9. Assignable. This conditional use permit is issued for the particular use and is not
personal. The City shall be notified in writing at the address provided in section 5 above of any
changes in the leasehold interest or ownership of the underlying property at least thirty (30) days
prior to such change.
10. Criminal Penalty. Violation of the terms of this conditional use permit is a criminal
misdemeanor.
Dated: December 14, 2009
CITY OF CHANHASSEN
BY: L4L�
Tom Furlong, Mayor
(SEAL)
Gerhardt, City Manager
STATE OF MINNESOTA )
(ss
COUNTY OF CARVER )
The foregoing instrument was acknowledged before me thisl l day of be-cem6te 20Q-9,
by Thomas A. Furlong, Mayor, and by Todd Gerhardt, City Manager, of the City of Chanhassen, a
Minnesota municipal corporation, on behalf of the corporation and pursuant to the authority granted
by its City Council. ,
DRAFTED BY:
City of Chanhassen
P. O. Box 147
7700 Market Boulevard
Chanhassen, MN 55317
(952)227-1100
' NOTARY PUBLIC
7KiM 7. MEUWISSEN
VJ-Notary Fublic-nesotaJen32010, cgnmission Expi
oct-i°�
Chanhassen City Council — December 14, 2009
e. Resolution #2009- 89: 2010 Street Improvement Project 10-01: Accept Feasibility
Report; Call Public Hearings for Red Cedar Point and Erie Avenue Areas.
f. Resolution #2009-90: Well No. 14, Project 10-03: Approve Plans and Specifications;
Authorize Advertising for Bids.
g. Resolution #2009-91: Approval of Vehicle Purchases Consistent with the Capital
Improvement Project.
h. Resolution #2009-92: Chanhassen Public Works Facility, Project 08-03: Approve
Change Order #3.
i. American Tower Corporation: Approve Amendment to Conditional Use Permit 09-3 to
Allow Co-Location/Addition of ITT/FAA Antennas and Radio Equipment at an Existing
Telecommunications Tower, 2290 Lyman Boulevard.
j. Resolution #2009-93: Approve Resolution Amending the 2009 Budget.
k. Resolution #2009-94: Extend Authorization for Mayor, City Manager and Finance
Director to Execute Refunding Bonds Without Prior Council Approval.
1. Resolution #2009-95: Approve Resolution Establishing Procedures Relating to
Compliance with Reimbursement Bond Regulations under the Internal Revenue Code.
in. Resolution #2009-%: Resolution Approving a Land Use Plan Amendment, Re -Guiding
Lot 1, Block 1, West One Addition from Commercial to Office Industrial (7900 Kerber
Boulevard).
n. Approval of Temporary On -Sale Intoxicating Liquor License, February Festival,
February 6, Chanhassen Rotary Club.
o. Approve Tower Lease Agreement with Clear Wireless, LLC for Murray Hill Water
Tower and Lake Lucy Water Tank.
All voted in favor and the motion carried unanimously with a vote of 5 to 0.
VISITOR PRESENTATIONS: None.
PUBLIC HEARING ON FIVE YEAR STREET RECONSTRUCTION PLAN.
Paul Oehme: Good evening Mayor, City Council members.
Mayor Furlong: Good evening.
Paul Oehme: Tonight staff would like to review the 5 year street improvement plan with council
and hold a public hearing and we are requesting that council provide preliminary approval for the
SCANNED
Chanhassen City Council — December 14, 2009
pleasing, improve property values and provide good stewardship so Greg and Colleen,
congratulations and thank you.
Greg Fletcher: Thank you very much.
Mayor Furlong: We have a Certificate of Recognition as well so thank you very much. At this
time I'd like to invite members of the St. Hubert's Church and School. I think we have one of
the teachers, Layne Bensiek here and some students as well. Project Reduce, Reuse and Recycle
programs in the church and school was the winner of this year's award. This year St. Hubert's
Church and School decided to do things a little bit differently. Instead of going with the status
quo they made some environmental changes throughout their building. Some of the changes
were small but some big but they all added up to a significant difference in the church and the
school's environmental impact. They discontinued using styrofoam cups and now use donated
coffee mugs. In the classrooms paper towels are no longer used but instead rags and natural
cleaners are used instead. In hallways and other rooms there's a greater quantity of recycling
bins to ensure access for everyone. They switched from, all from lighting to environmentally
friendly products and use only green cleaning solutions in their buildings. With the success and
accomplishments this year the school plans on forming a student green team, which I think we're
seeing the initial membership right here. Excellent. This year and into next year as well as
looking at other options such as composting organic waste in their cafeteria. So to the St.
Hubert's Church and School and the green team, thank you and congratulations. Move on now
to the next items on our agenda.
CONSENT AGENDA: Councilwoman Ernst moved, Councilwoman Tjornhom seconded
to approve the following consent agenda items pursuant to the City Manager's
recommendations:
a. Approval of Minutes:
-City Council Work Session Minutes dated November 23, 2009
-City Council Verbatim and Summary Minutes dated November 23, 2009
-City Council Verbatim and Summary Minutes dated December 7, 2009
Receive Commission Minutes:
-Planning Commission Verbatim and Summary Minutes dated December 1, 2009
-Park and Recreation Commission Verbatim and Summary Minutes dated November 24,
2009
b. Park and Recreation Volunteer Service Awards: Approve List of Winners.
C. Resolution #2009-87: Resolution Accepting Donations to Chanhassen Senior Center
from Community Bank.
d. Resolution #2009-88: Approve Resolution for Withdrawal and Termination from the
Joint and Cooperative Agreement with the Regional Mutual Aid Association for the Use
of Personnel and Equipment during Emergencies.
CITY of
CHANHASSEII
7700 Market Boulevard
PC Box 147
Chanhassen, MN 55317
Administration
Phone: 952.227.1100
Fax 952.227.1110
Building Inspections
Phone: 952.227.1180
Fax: 952.227.1190
Engineering
Phone: 952.227.1160
Fax: 952.227.1170
Finance
Phone: 952.227.1140
Fax: 952.227.1110
Park 8 Recreation
Phone: 952.227.1120
Fax: 952.227.1110
Recreation Center
2310 Coulter Boulevard
Phone: 952.227.1400
Fax: 952.227.1404
Planning &
Natural Resources
Phone: 952.227.1130
Fax: 952.227.1110
Public Works
1591 Park Road
Phone 952.227.1300
Fax:952.227.1310
Senior Center
Phone: 952227.1125
Fax: 952.227.1110
Web Site
www.ci.chanhassen.mn.us
C)9 - 1 9
December 15, 2009
Mr. Doug Ruwe
Project Manager — Site Development Services
American Tower Corporation
21307 Rio Oro Drive
Cornelius, NC 28031
Re: Conditional Use Permit Amendment — 2290 Lyman Boulevard
. Planning Case #09-19
Dear Mr. Ruwe:
This letter is to confirm that on December 14, 2009, the Chanhassen City Council
approved the amendment to Conditional Use Permit 90-3 to allow co-
location/addition of antennas and radio equipment upon and at the existing
telecommunication tower, plans prepared by Advanced Engineering and Science
dated 10/23/09, subject to following conditions
1. The tower and antennas shall comply with the requirements in Chapter 20,
Article XXX, Towers and Antennas, of the Chanhassen City Code.
2. A building permit is required for equipment pad and LP gas storage tank pad.
3. A mechanical permit is required for connection (gas piping) of LP storage
tank to LP gas generator_
4. The plans must be signed by appropriate design professionals.
5. No signage, advertising or identification of any kind intended to be visible
from the ground or other structures is permitted, except applicable warning
and equipment information signage required by the manufacturer or by
Federal, State, or local authorities.
Chanhassen is a Community for Life. Providing for Today and Planning for Tomorrow
SCANNED
Mr. Doug Ruwe
December 15, 2009
Page 2
The City will record the amended and restated Conditional Use Permit for the property. If you
have any questions or need additional information, please contact me at (952) 227-1131 or
bgenerous@ci.chanhassen.mn.us.
Sincerely,
Robert Generous, AICP
Senior Planner
RG:ktm
ec: Kate Aanenson, Community Development Director
Todd Gerhardt, City Manager
Jerry Mohn, Building Official
cc: Merle and Jane Volk
gAplant2009 planning casesN09-19 arnerican tower cup 90.3 am dtnenttapproval letter.doc
U .......,Id
CITIIOF
C9AN9ASSEN
7700 Market Boulevard
PO Box 147
Chanhassen, MN 55317
Administration
Phone: 952.227.1100
Fax: 952.227.1110
Building Inspections
Phone: 952.227.11 BO
Fax: 952.227.1190
Engineering
Phone: 952.227.1160
Fax: 952.227.1170
Finance
Phone: 952.227.1140
Fax: 952.227.1110
Park & Recreation
Phone: 952.227.1120
Fax: 952.227.1110
Recreation Center
2310 Coulter Boulevard
Phone: 952.227.1400
Fax: 952.227.1404
Planning &
Natrmal Resources
Phone: 952.227.1130
Fax: 952.227.1110
PubBc Works
1591 Park Road
Phone: 952.227.1300
Fax: 952.227.1310
Senior Center
Phone: 952.227.1125
Fax: 952.227.1110
Web Site
www.ci,chanhassen. mn.us
off- a 9
MEMORANDUM
TO: Todd Gerhardt, City Manager
FROM: Bob Generous, Senior Planner
DATE: December 14, 2009 61i,,./A
SUBJ: CUP Amendment — American Tower Company
Planning Case #09-19
PROPOSED MOTION
"The Chanhassen City Council approves the amendment to Conditional Use
Permit 90-3 to allow co-location/addition of antennas and radio equipment
upon and at the existing telecommunication tower, plans prepared by Advanced
Engineering and Science dated 10/23/09, subject to conditions I - 5 and
adoption of the Planning Commission's findings of fact."
City Council approval requires a majority vote of City Council present.
EXECUTIVE SUMMARY
The applicant is requesting an amendment to Conditional Use Permit 90-3 to allow
co-location/addition of 1TT/FAA antennas and radio equipment at an existing
telecommunication tower. One of the conditions of the original approval was that
"no other radio uses shall be approved without an addendum to the conditional
use permit #90-3 which will come in before the Planning Commission and City
Council".
PLANNING COMMISSION SUMMARY
The Planning Commission held a public hear on December 1, 2009 to review the
request. The Planning Commission voted six for and none against a motion
recommending approval of the amendment to the CUP. There were no issues or
objections to the request. The only question was whether there was a limit on the
number of antennas that may be attached to the structure. The applicant advised that
there is a limit based on an engineer's review of the tower and antennas since there
is a finite carrying capacity for the tower based on its design and construction.
The Planning Commission minutes for December 1, 2009 are item la of the
December 14, 2009 City Council packet.
pBNNV3=
Chanhassen is a Community for life - Providing for Today and Planning for Tomorrow
Todd Gerhardt
CUP Amendment — American Tower Company
December 14, 2009
Page 2
RECOMMENDATION
Staff and the Planning Commission recommend adoption of the motion as specified on page 5 in
the staff report dated December 1, 2009 approving the amendment to CUP #90-3.
ATTACHMENT
Planning Commission Staff Report Dated December 1, 2009.
gAplant2009 planning cases\09-19 american tower cup 90-3 amendment\czecutive summary.doc
CITY OF CHANHASSEN
PROPOSED MOTION:
PC DATE: December 1, 2009 ❑
CC DATE: December 14, 2009
REVIEW DEADLINE: December 29, 2009
CASE #: 09-19
BY: AF, RG, JM, JS
"The Chanhassen Planning Commission recommends that City Council approve the amendment to
Conditional Use Permit 90-3 to allow co-location/addition of antennas and radio equipment upon and
at the existing telecommunication tower, plans prepared by Advanced Engineering and Science dated
10/23/09, subject to conditions 1 - 5 and adoption of the attached findings of fact and
recommendations."
SUMMARY OF REQUEST: The developer is requesting an amendment to Conditional Use
Permit 90-3 to allow co-location/addition of ITT/FAA antennas and radio equipment at an existing
telecommunication tower.
LOCATION: 2290 Lyman Boulevard (Outlot B, Stone Creek First Addition)
APPLICANT: American Tower Company OWNER: Merle and Jane Volk
PRESENT ZONING: Agricultural Estate District, A-2
2020 LAND USE PLAN: Residential — Low Density
ACREAGE: DENSITY: Not applicable
LEVEL OF CITY DISCRETION IN DECISION-MAKING:
The City has limited discretion in approving or denying conditional use permits, based on
whether or not the proposal meets the conditional use permit standards outlined in the Zoning
Ordinance. If the City finds that all the applicable conditional use permit standards are met, the
permit must be approved. This is a quasi-judicial decision.
PROPOSAL/SUMMARY
The applicant is requesting an
amendment to Conditional Use
Permit 90-3 to allow co-
location/addition of antennas and
equipment upon and at an
existing telecommunication
tower.
To the north of the site are
single -fancily homes on property
zoned RSF located within the
Planning Commission
American Tower Corporation CUP
December 1, 2009
Page 2 of 5
Stone Creek subdivision. To the east are the Twin Cities & Western Railroad and the athletic fields
for Chanhassen High School. To the south across Lyman Boulevard is industrial development in
the City of Chaska. To the west are farm fields associated with Holasek Nursery.
When the communication tower was originally approved, cellular communication was a fairly new
technology. Additionally, the only standards the City had at the time was that the use was a
conditional use in the Agricultural Estate District, the general CUP issuance standards and the
requirement that towers be setback from the property line a minimum of the height of the tower or
the tower must be self -collapsing.
Since the original CUP approval, the City has
adopted an entire section of the Code that addresses
Towers and Antennas, Chapter 20, Article XXX.
These standards permit a reasonable and equitable
opportunity for the establishment of
telecommunication services, ensure that towers and
antennas are designed and constructed in a manner
that does not adversely impact public safety
(height, setback and construction standards),
maximize the use of existing and approved towers
and buildings for antennas in order to reduce the
number of towers required (co -location) and
minimize adverse visual effects of towers through careful design and siting standards.
and proposed use of the site for telecommunication purposes complies with these requirements.
The existing
Staff is recommending approval of the amendment to the CUP to permit the co -location of
antennas and equipment at the existing tower site.
APPLICABLE REGUATIONS
Chapter 20, Article IV, Conditional Uses
Section 20-572 (2), Permitted Uses in the "A-2" Agricultural Estate District — Antennas
20-574 (15), Conditional Uses in the "A-2" Agricultural Estate District—Towers
Chapter 20, Article XXX, Towers and Antennas
BACKGROUND
Conditional Use Permit #90-3
On September 10, 1990, the Chanhassen City Council approved a conditional use permit for a
commercial communication transmission tower to support cellular telephone service. The
conditions of approval were as follows:
1. Staff will approve the aesthetic design of the tower and building and the building should be
consistent with other recently constructed telephone and public utility buildings in the area.
Planning Commission
American Tower Corporation CUP
December 1, 2009
Page 3 of 5
2. Staff will approve and document the tower shape and structure and that it's construction will
follow that approval.
3. No other radio uses shall be approved without an addendum to the
conditional use permit #90-3 which will come in before the
Planning Commission and City Council.
4. Landscaping shall be installed as part of the approved landscaping
plan. A letter of credit guaranteeing improvements will be required
before building permits are issued.
5. No lights or signage be placed on the tower or elsewhere on the
site.
6. The tower shall be painted a flat color so that it blends in with the
background.
Recorded on October 5, 1990 as document number 118396.
Subdivision #92-1
On February 22, 1993, the Chanhassen City Council approved the final plat for Stone Creek First
Addition, creating Outlot B. The tower was already located on the parcel at the time of platting.
ANALYSIS
A building permit is required for equipment pad and
LP gas storage tank pad. A mechanical permit is
required for connection (gas piping) of LP storage
tank to LP gas generator. The plans must be signed
by appropriate design professionals.
The plans submitted show proposed improvements
within the existing pad located north of Lyman
Boulevard between Galpin Boulevard and the
railroad tracks. The applicant does not propose to
expand the existing impervious surface. There is no
grading proposed.
Since the tower already exists, the City would normally review the proposed additional
equipment and tower through the building permit process. However, due to condition 3 of CUP
#90-3, the equipment and antenna must be approved through the public hearing process. Staff is
proposing that the conditions of approval be amended to require compliance with the City Code
standards for towers and antennas which would encourage and permit the co -location of antennas
and equipment at and upon the existing tower.
Planning Commission
American Tower Corporation CUP
December 1, 2009
Page 4 of 5
GENERAL CONDITIONAL USE PERMIT
The applicant is requesting an amendment to the Conditional Use Permit to permit the co -
location of antennas and equipment on the existing tower. The City's Zoning Ordinance allows
telecommunication towers and antennas in Agricultural Estate Districts subject to the approval of
a conditional use permit by the City Council. In reviewing conditional use permit requests, the
Planning Commission must consider possible adverse affects of the use.
The City of Chanhassen finds it necessary for the promotion and preservation of the public
health, safety, welfare, and aesthetics of the community that the construction, location, size, and
maintenance of wireless telecommunication facilities be controlled. Further, the City finds:
Towers and antennas have a direct impact on, and a relationship to,
the image of the community;
2. The manner of installation, location, and maintenance of towers and
antennas affects the public health, safety, welfare, and aesthetics of
the community;
3. A reasonable opportunity for the establishment of wireless
telecommunication must be provided to serve residential and business
needs, and;
4. Uncontrolled and unlimited towers and antennas adversely impact the
image and aesthetics of the community and, thereby, undermine
economic value and growth.
Given that it is the City's goal is to minimize towers, the amendment of
the CUP to permit co -location of antennas and equipment is appropriate.
COMPLIANCE
Height Setback
Code 1 150* Structure height
American Tower 1 115 175 feet
*May be increased 25 feet for multi -antenna towers.
RECOMMENDATION
Staff and the Planning Commission recommends that City Council
adopt the following motion and adoption of the attached findings of fact and FeeemEnendation:
Planning Commission
American Tower Corporation CUP
December 1, 2009
Page 5 of 5
"The Planning CeRwpAssien Feeonmmnds appmval e City Council approves Conditional Use
Permit #09-19, amending Conditional Use Permit 90-03, to permit co-location/addition of antennas
and equipment upon and at the existing telecommunication tower, plans prepared by Advanced
Engineering & Sciences, dated 10/23/09, subject to the following conditions:
1. The tower and antennas shall comply with the requirements in Chapter 20, Article XXX,
Towers and Antennas, of the Chanhassen City Code.
2. A building permit is required for equipment pad and LP gas storage tank pad.
3. A mechanical permit is required for connection (gas piping) of LP storage tank to LP gas
generator.
4. The plans must be signed by appropriate design professionals.
5. No signage, advertising or identification of any kind intended to be visible from the ground
or other structures is permitted, except applicable warning and equipment information
signage required by the manufacturer or by Federal, State, or local authorities"
ATTACHMENTS
1. Findings of Fact and Recommendation.
2. Development Review Application.
3. Reduced copy of Compound Plan Sheet 3 of 18.
4. Reduced Copy Tower Profile Sheet 4 of 18.
5. Letter from Doug Ruwe to City of Chanhassen Dated October 29, 2009.
6. Permit Authorization by ITT Corporation.
7. Letter from Richard L. Day to Greg Hughes dated January 2, 2008.
8. Email Correspondence between Tim Jeske, Bob Generous and Doug Ruwe between
November 16 and November 18, 2009.
9. Amended and Restated Conditional Use Permit.
10. Reduced Copy Site Plan Dated 7-16-90.
11. Conditional Use Permit 90-3 dated September 10, 1990.
glplan\2009 punning cases\09-19 anterit= tower cup 90-3 amendmenAstaB report atuerican tower.doc
CITY OF CHANHASSEN
CARVER AND HENNEPIN COUNTIES, MINNESOTA
FINDINGS OF FACT
AND RECOMMENDATION
Application of American Tower and Merle and Jane Volk for an amendment to the existing
Conditional Use Permit 90-3 to permit the installation of additional antennas and equipment at
and upon an existing telecommunication tower.
On December 1, 2009, the Chanhassen Planning Commission met at its regularly
scheduled meeting to consider the application of American Tower and Merle and Jane Volk for
an amendment to a conditional use permit to permit a telecommunication tower for the property
located at 2290 Lyman Boulevard. The Planning Commission conducted a public hearing on the
proposed conditional use was preceded by published and mailed notice. The Planning
Commission heard testimony from all interested persons wishing to speak and now makes the
following:
FINDINGS OF FACT
The property is currently zoned Agricultural Estate District, A-2.
2. The property is guided by the Land Use Plan for Residential — Low Density.
3. The legal description of the property is: Outlot B, Stone Creek First Addition.
4. Conditional Use Permits
a. The proposed use will not be detrimental to, but may enhance the public health,
safety, comfort, convenience or general welfare of the neighborhood or the city. The
proposed tower will provide a basic utility to the area.
b. The proposed use will be consistent with the objectives of the city's comprehensive
plan and this chapter.
c. The proposed use will be designed, constructed, operated and maintained so to be
compatible in appearance with the existing or intended character of the general
vicinity and will not change the essential character of that area. The proposed tower
complies with city ordinance requirements. The lower portion of the tower including
the equipment will be screened by vegetation and a berm.
d. The proposed use will not be hazardous or disturbing to existing or planned
neighboring uses.
e. The proposed use will be served adequately by essential public facilities and services,
including streets, police and fire protection, drainage structures, refuse disposal, water
and sewer systems and schools; or will be served adequately by such facilities and
services provided by the persons or agencies responsible for the establishment of the
proposed use.
The proposed use will not create excessive requirements for public facilities and
services and will not be detrimental to the economic welfare of the community. It
will provide a necessary utility.
g. The proposed use will not involve uses, activities, processes, materials, equipment
and conditions of operation that will be detrimental to any persons, property or the
general welfare because of excessive production of traffic, noise, smoke, fumes, glare,
odors, rodents, or trash. The tower should not create conditions that are detrimental
to person's property or the general welfare of the community.
h. The proposed use will have vehicular approaches to the property which do not create
traffic congestion or interfere with traffic or surrounding public thoroughfares.
i. The proposed use will not result in the destruction, loss or damage of solar access,
natural, scenic or historic features of major significance.
j. The proposed use will be aesthetically compatible with the area.
k. The proposed use will not depreciate surrounding property values.
1. The proposed use will meet standards prescribed for communication towers as
provided in zoning ordinance.
5. The Planning Report #09-19 dated December 1, 2009, prepared by Robert Generous, et
al, is incorporated herein.
RECOMMENDATION
The Planning Commission recommends that the City Council approve the amendment to
the conditional use permit for a telecommunication tower.
ADOPTED by the Chanhassen Planning Commission this J." day of December, 2009.
CHANHASSEN PLANNING COMMISSION
I=
Its Chairman
PLEASE PRINT
CITY OF CHANHASSEN
7700 Market Boulevard — P.O. Box 147
Chanhassen, MN 55317 — (952) 227-1100
DEVELOPMENT REVIEW APPLICATION
icant Name and Address:
g Ruwe - American Tower
21307 Rio Oro Dr
Cnrnplinc NC 280-31
Contact:
Phone: 704-975-6161 Fax:
Email: Toug.ru—we@americantower.com
Planning Case No. OSI I
.a i'I O� UHANHASSEi`d
RECEIVED
OCT 3 0 2009
CHANHASSEN PLANNING DEPT
Owner Name and Address:
Merle & Jane Volk
16925 County RD 40
rarvpr, MN 55311,
Contact:
Phone: Fax:
Email:
NOTE: Consultation with City staff is required prior to submittal, including review of development
plans
Comprehensive Plan Amendment
X Conditional Use Permit (CUP)
Interim Use Permit (IUP)
Non -conforming Use Permit
Planned Unit Development*
Rezoning
Sign Permits
Sign Plan Review
Site Plan Review (SPR)*
Subdivision*
Temporary Sales Permit
Vacation of Right-of-Way/Easements (VAC)
Variance (VAR)
Wetland Alteration Permit (WAP)
Zoning Appeal
Zoning Ordinance Amendment
Notification Sign$200
(City to install and re ove)
X Escrow for Filing Fees/Attorney Cost**
- $50 CUPYSPR/VACfVAR/WAP/Metes & Bounds
-$4501�1inor SUB
TOTAL FEE $
An additional fee of $3.00 per address within the public hearing notification area will be Invoiced to the applicant
prior to the public hearing.
*Sixteen (16) full-size folded copies of the plans must be submitted, including an 81/:" X 11"
reduced copy for each plan sheet along with a digital copy in TIFF -Group 4 (*.tif) format.
**Escrow will be required for other applications through the development contract.
Building material samples must be submitted with site plan reviews.
NOTE: When multiple applications are processed, the appropriate fee shall be charged for
each application.
PROJECTNAME: ITTSV173-21 Colocation
v
LOCATION: 2290 L _ I Chanhassen, NIld 55317
LEGAL DESCRIPTION AND PID: -94--3413J-12- as —$1
TOTAL ACREAGE:
WETLANDS PRESENT: YES X NO
PRESENTZONING: Commercial
REQUESTED ZONING: Commercial - amend CUP 90-3
PRESENT LAND USE DESIGNATION:
REQUESTED LAND USE DESIGNATION:
REASON FOR REQUEST:
To allow the colocation/addition of ITT/FAA antennas
and radio equipment at an existing telecommunication tower.
FOR SITE PLAN REVIEW: Include number of existing employees:
and new employees:
This application must be completed in full and be typewritten or clearly printed and must be accompanied by all information
and plans required by applicable City Ordinance provisions. Before filing this application, you should confer with the
Planning Department to determine the specific ordinance and procedural requirements applicable to your application.
A determination of completeness of the application shall be made within 15 business days of application submittal. A written
notice of application deficiencies shall be mailed to the applicant within 15 business days of application.
This is to certify that I am making application for the described action by the City and that I am responsible for complying with
all City requirements with regard to this request. This application should be processed in my name and I am the party whom
the City should contact regarding any matter pertaining to this application. I have attached a copy of proof of ownership
(either copy of Owner's Duplicate Certificate of Title, Abstract of Title or purchase agreement), or I am the authorized person
to make this application and the fee owner has also signed this application.
I will keep myself informed of the deadlines for submission of material and the progress of this application. I further
understand that additional fees may be charged for consulting fees, feasibility studies, etc. with an estimate prior to any
authorization to proceed with the study. The documents and information I have submitted are true and correct to the best of
my knowledge.
Signature of Applicant Date
Signature of Fee Owner Date
G. \p1an\fortns0evelopment Review Application. DOC Rev. 1108
..
COMPOUND NOTES
HEIONi EMCLUDING ME LOWER, NO ENISTNC OR PROMISED
STRUCTURE (INCLUDING EOUIPMENTI WILL UCEEO THE HOW
THIS
15 REQUIRED, ONE ENInNG
NOT PROPOSED EAGER, AS
ROPOSED FACTUM WILL RESULT IN
STORM WATER RUNKI
Lltt CONTROL DIMCES ARE
IF -WAY OR
WILL RESULT
COMPOUND VIEW
20' N 1W PAM ACCESS DANE
(1) PMNIN4
SPACE
EXISTING
LES.EEE/I1P
SXELRR
PROPOSED"
IV K 13'
EQUIPMENT PM
WITHIN I9' x LD'
LEASE AREA
ITT
TO
COMING CIwxUNN
FENCE WM9F/]-ESTRAND
BARBED
PROPOSED IR
POWER RIAMNO
MVEL \\
SUFRCCI
LAME
TOMER
N
COMPOUND PLAN
SHJ SCALE: I':5' (EASED ON 24%36 "D' PAPER SIZE
TRUE NORTH SCALE: I'�10' (BASED ON IIK17 'B' PAPER SIR)
I No SPARK
Ly 'c o; mlJer m
V
R
isw1:.'-. .. +dL11y Licen c
u
1
\\
PROPOSED m
12D AN
PROPANE LINN
Si
I ILTa: ✓ �'
PRCPoAD Iii
]'-0' M ]'-0'
cavunE PAD DI
M 110 GALLON
l0k)�� Liccnsey 445
X /
PROPANE TANK
ITT
— PROPOSED m12975
PROPOSED
WGrWgete DINe
DAs UNE RGUIIHC
Hemdom VA. 20170
Notice:
�al�wva.N
2m
AE
HAZELTINEIITTSV173-21
xl
2290 LYMAN RD
TIIJC LIN SS117
EO m NONA
K 12' A e' e01
IT
MAellen. PP
81388
UDE=D 9M715
DPPMXGNIIWER 811E PEV
NOTE:
SEE PROPOSED ICE BRIDGE, SHEET 9 4339611<3 ID 2
G'.
— 3 v 18 MME
1. SEE DRAWING SHEET 3 FOR COMPOUND PLAN,
2. ALL THREADED STRUCTURAL FASTENERS TOR ANTENNA
SUPPORT ASSEMBLIES SHALL CONFORM TO ASTM M07
OR ASTM ASB. ALL STRUCTURAL FASTENERS FOR
STRUCTURAL STEEL FRAMING SMALL CONFORM TO ASTM
A325. FASTENERS SHALL BE S/B• MIN. DM. BALING
TYPE CONNECTIONS WITH THR EXCLUDED FOR THE
PLANE. ALL EXPOSED FASTENERS. NLRB. AND WASHERS
SMALL BE G VANIZED UNLESS OTHERWISE NOTED,
CONCRETE EXPANSION ANCHORS SMALL BE HILTI KWIK
BOLTS UNLESS OTHERWISE NOTED, ALL ANCHORS INTO
CONCRETE BR4L BE STAINLESS STEEL.
3. THE GENERAL CONTRACTOR/SUB CONTRACTOR SMALL
FURNISH ALL CONNECTION HARDWARE REQUIRED TO
SECURE THE CABLES. CONNECTION HARDWARE SMALL
BE STAINLESS STEEL
4. NORM ARROW SHOWN ON THE PLANS REFERS TO
TRUE NORTH. THE GENERAL CONTRACTOR/SUB CONTRACTOR
SHALL VERIFY NORTH AND NOTIFY ITT CORPCW OF
ANY DISCREPANCY BEFORE STARTING CONS MON.
I. PRONDE LOCK WASHERS FOR ALL MECHANICAL
CONNECTIONS FOR GROUNDING CONDUCTORS. USE
STAINLESS STEEL HARDWARE THROUGHOUT.
S. THOROUGHLY REMOVE ALL PLANT AND CLEAN ALL
DIM FROM SURFACES REQUIRING GROUND CONNECTIONS,
]. MAKE ALL GROUND CONNECTIONS AS SHORT AND
DIRECT AS POSSIBLE AVOID SHARP BENDS. ALL BENDS
TO BE A MIN. OF B• RADIUS.
B. FOR GROUNDING i0 BUILDING FRAME AND HATCH
PLATE GROUND RAPS. USE A TWO -SOLI HOLE NEW
DRILLED CONNECTOR SUCH AS A TWO 32007 OR
AN APPROVED EQUAL PAM.
B. FOR ALL EXTERNAL GROUND CONNECTIONS. CLAMPS
AND CADWEWS. APPLY A LIBERAL PROTECTIVE COATING
OR AN ANTI -OXIDE COMPOUND SUCH AS -NO-OXIDE A•
BY DFMBORN CHEMICAL COMPANY.
10. REPAIR ALL GALVANIZED SURFACES THAT HAVE BEEN
DAMAGED BY THERMOWELDING MAIM COLD C V. PAINT,
11, SEAL ALL CONDUITS PENETRATIONS IMO STRUCTURES
AND ALL CONDUIT OPENINGS WITH A SILICONE SEALANT.
12. THE COAXIAL ANTENNA CABLE INSTALLER SHALL BE
RESPONSIBLE FOR PERFORMING AND SUPPLYING WEEP
TESTS (ANTENNA RETURN LOSS TEST). THIS TEST SMALL B
PERFORMED TO THE SPECIFICATIONS AND PARAMETERS
OUTLINED GY MEM CORP MAOIO FREQUENCY THRU
ENGINEER. MESE TESTS SMALL BE PERFORMED PRIOR TO
FINAL ACCEPTANCE OF THE SITE.
13. ME COAXIAL. ANTENNA CABLE INSTALLER SHALL BE
RESPONSIBLE FOR PERFORMING AND SUPPLYING RT CORP.
WITH TIME DOMAIN REFIECTOMETER TESTS TO VERIFY CARL
LENGTH AND TO CHECK FOR WATER DAMAGE.
14. VAPOR WRAP WILL BE USED TO SEAL ALL
CONNECTIONS.
15, ALL JUMPERS TO THE ANTENNAS FROM A MAIN
TRANSMISSION LINE WILL BE 1/2- DN AND SHALL
NOT EXCEED W-0'.
18. ALL COAXIAL CABLE WILL BE GROUNDED PRIOR TO
ENTERING THE EQUIPMENT SHELTER AND AS
SPECIFIED IN THE ELECTRICAL DRAWINGS.
17. ALL COAXIAL CABLE WILL BE SECURED TO THE
DESIGNED SUPPOMMG STRUCTURE AT DISTANCES
NOT TO EXCEED 4'-0- WITH HARDWARE SPECIFIED
IN THE COAXIAL CABLE ROUTING DETAILS,
IB, ANTENNA CABLE LENGTHS NAVE BEEN DETERMINED
BASED ON THESE PUNS. CABLE LENGTHS U51ED
ARE APPROXIMATED AND ARE NOT EEDS 0 N BE
USED FOR FABRICATION WE TO FIELD CONDITIONS.
THE CONTRACTOR MUST FlELD VERIFY ALL ANTENHM
CABLE LENGTHS PRIOR TO ORDER.
19, ALL MAIN CABLES WALL BE COLOR CODED AT
THREE LOCATIONS IAA MAIL B SHEET 4.
A. AT ME ANTENNA PRIOR VO JUMPER
8. AT THE CABLE BRIDGE EWE AT BASE OF TOWER
C. AT THE EQUIPMENT PRIOR TO JUMPER
20. RF CONNECTIONS SHALL BE TORQUED TO MNIUFICTURER'I
RECOMMENDATIONS. LOOSE CONNECTIONS WILL BE THE
COMRACTORS RESPONSIBILITY TO CORRECT.
A CALIBRATED TORQUE WRENCH SMALL BE USED ON ALL
RF CONNECTIONS
FINAL ANTENNA L MOUNT ADASTMENTS SMALL BE
COMPLETED USING A MODEL R SPMOS-NCX,
INFORMATION CAN BE FOUND ON THE VEB AT
VVV.SPAAMCCN/INDE%.PNP FINAL DATA SHALL BE
INCLUDED IN THE CLOSE -CUT PACKAGE.
NEW ITT CORP
ANTENNAS MR. OF 5)—\
AND (1) VERTEX
ANTENNA.
ITT CORP PROJECT
MANAGER TO PROVIDE
ACTUAL ORIENTATION
OF ANTENNA.
ATC STRUCTURAL
AND CENTER OF
MOUNT - BS' -0 -
PROPOSED ITT CORPORATION
99A-3' ANTENNA RAD CENTER 2.
AOI_
PROPOSED RT CORPORATION
�93'-6- ANTENNA M. O BOTTOM
OF MOUNT
LGL.
ANTENNA
115'-G' TOP OF STEEL
ITT
) RT CORPORATION
HT. O 8070M OF
B COAX LAYOUT DETAIL
SHIT HOT TO SCALE
IMAI1
IC54'
N i i'i1•Y=��'. C :"LliiLoF
PrP
Z WfiAl
+14snnnl '.-_ _. .,dl the has
j
F v
XE
EERIONI OCtf
W
VERBA 0"JO
Mr -+-13r
1131 718 -
MAY CABLES
w-3'
1 o L L1CCIla[ N 4'
W=:
pnaM
1 Mr-1-1M
HUMM,
I T T
BnjIMY6B%
PROPOSED lii —' V
OPER STRUCTURAL
O) 1 5/8' AND
4/3396123 DATED
�MMW
COAX CABLES
06/03/09 INSTALL
M'411wIai,�+44F,W
12975 W0TIOQ8b 0*8
WA
PROPOSED COAX LINES
TRUE NORTH
M EMPTY TOWER LEG,
HMMMIL VA. 20170
B COAX LAYOUT DETAIL
SHIT HOT TO SCALE
IMAI1
A®mCA,M r4rna4m1o111
Mr -+-13r
lX/XX
w-3'
WA
W=:
pnaM
1 Mr-1-1M
HUMM,
.'-3'
WA
m^W
-r
WA
FIeoTrtu
WA
YFMw
, en -,-,v
n/q
wo•
WA
"A,M1SP
• ]/r -,-1u
RI/lel
WA
• UI 1 V.- WMA uo NW (1) ]M' mAx uK M, 4[ M M:N mw0wlXw.
MF Ig011W .1. AMID M Irt.
D ANTENNA SYSTEM MARKING AND LABELING
BHI NOT TO I.
gA TOWER PROFILE
SHI NOT TO I..
WAA,,XY PP
SMO- 81388
<ADLcme 9X715
MM
433961W_1K 13,
R
DO
F. 4 a IS 1 NOME
I.\
AMERICAN TOWER'
co R O SAT I0N
October 29, 2009
City of Chanhassen
Community Development — Bob Generous
7700 Market Boulevard, PO Box 147
Chanhassen, MN 55317
RE: MSV173-07 ITT FAA Collocation
American Tower Site Code: 305556
2922 Hibbard Rd
Parcel Number 11-04-200-003
Dear Bob:
CITY OF CHANHASSEN
RECENED
OCT 3 0 2009
CHANHASSEN PLANNING DEPT
As we discussed, enclosed please find: City of Chanhassen Development Review Application to amend CUP90-3,
(2) letter of authorization (ITT/FAA), copy a stamped construction drawings for ITTSV 173-21, a stamped structural
analyses, and a check for $675.00 for the review fee for the zoning your review. Hopefully we can still make the
December meeting agendas.
Specifically, ITT is applying for zoning and building permits to collocate six (6) antennas and coaxial lines on the
existing tower referenced above. They will also be installing a radio equipment cabinet, an emergency back-up
diesel generator on a new concrete pad within the existing fenced compound. The tower will not increase in height
and the compound will not increase in size due to the installation. The purpose of this collocation is the replacement
of the existing FAA air navigation system. Once implemented, this new technology will greatly enhance the safety
of the traveling public in all types of aircraft. The total job cost is expected to be $30,000.00.
At this time American Tower has not selected a contractor, but once the use has been approved and the fees
determined, we will have the general contractor complete the building permit applications and pay any outstanding
fees. Please let me know if the material provided is deficient, or if you need any additional information. Should you
have any questions please contact me at (704) 975-0161 or by e-mail doug.ruwe@americantower.com.
American Tower greatly appreciates your assistance with this permit request.
Sincerely,
Doug Rowe
Project Manager Site Development
(704) 975-6161
doug.ruwe@AmericanTower.com
Enclosures
21307 Rio Oro Dr • Comedus NC 28031 • (704) 975.6161 • doug.ruwe@amedcantower.com
SCANNED
TT
PERMIT AUTHORIZATION
Advanced Engineering & Sciences
12975 Worldgate Oriw
Herndon. VA 20170
I hereby authorize American 'Power Corporation to act as agent for ITT Corporation, Advanced
Engineering & Sciences Division in the application for all permits and utility services associated with
this site.
ITT Corporation
Advanced Engineering & Sciences Division
An Indiana Corporation
l
Ery: Frank Pallante
Title: Vice President of Contracts
Date: -5— /7
COMMONWEALTH OF VIRGINIA
COUNTY OF FAIRFAX
The foregoing document was acknowledged before me this I ;. day ofk.,,, 2009 by
FYnv Yu iron]-- , who is personally known to me.
('ummy01_ ria:
i:0mmonweamvst tg Of—V
The foregoing instrgmglk d
before me this fay of N.av
201 by _ —�--'
_.
name o Perspi se ----
Jo Y�6Ic n
"'rnmmissitul expires' r�4Lt�cv- q1, Z10f-2
MYCommts m 6OUAWA31,IM
[D#71%%7
SCANNED
.»... ., :..n+:h�+w�r�t' •.wi+...s - -v.. � ':•rte
\_
V.S. Deoodmenr
of Iramupodotion
Federal Aviation
Administration
Mr. Greg Hughes
Contracts Manager, ADS -B Programs
ITT Corporation
Defense Electronics & Services
12975 Worldgate Drive
Herndon, VA 20170-6008
Re: Automatic Dependent Surveillance -Broadcast (ADS -B)
Contract DTFAWA-07-C-00067
Dear Mr. Hughes:
This letter serves to emphasize to you and your potential partners the importance of the
Federal Aviation Administration (FAA) AUS -B contract which was awarded to ITT
Corporation on August 30. 2007.
The FAA is undertaking a dramatic modemization of the National Airspace System under a
program entitled Next Generation Air Traffic Management Systems (NextGcn). The ADS -
B program is the comerstonc of the NextGen. ADS -B will provide technology that in the
near term will enhance safety and in the longer term promise significant system capacity and
efficiency benefits essential to meeting forecasted increases in air traffic demand.
ADS -B is and will remain a high visibility program. Avionics manufacturers and aviation
organizations/companies are relying on the FAA to meet the ADS -B implementation
schedule. The FAA has begun full scale development of the ADS -B system with the award
of the 177 contract and wi I1 begin nation wide deployment in the near term.
Any support that can be given to ITT in the development and fielding of ADS -B
infrastructure is strongly encouraged. The FAA considers this program an opportunity to
significantly benefit the nation's transportation infrastructure with new technology.
It is believed that just as in the introduction of the internet, there will be many spin-off
opportunities.
SItc
Riche Day
Vice President
En Route and Oceanic Serviges
J;
Generous, Bob
From: Tim Jeske [fJeske@TCWR.NET]
Sent: Wednesday, November 18, 2009 8:58 AM
To: Generous, Bob
Subject: RE: Planning Case 09-19
:..
Thank you for asking, it appears that we will not have interference with our radio communications. If so, we don't have any
additional comments.
fii,
From: Generous, Bob [mailto:bgenerous@ci.chanhassen.mn.us]
Sent: Wednesday, November 18, 2009 8:22 AM
To: Tim Jeske
Subject: FW: Planning Case 09-19
Tim:
Is there anything else you would need.
t.r
From: Doug Ruwe[mailto:Doug.Ruwe@AmericanTower.com]
Sent: Monday, November 16, 2009 11:19 AM
To: Generous, Bob
Cc: Doug Ruwe
Subject: RE: Planning Case 09-19
M
As with any equipment mounted on American Tower owned sites, the users are licensed with the FCC for a
specific frequency range. I have requested a copy of the FCC license. It should not interfere with any other
radio equipment. Assuming all radio equipment, ITT's and the railroad's is operating correctly.
Also, I have lost my notes for the meeting dates in December. Could you list the dates and times?
Thanks,
Doug Ruwe
Project Manager- Site Development Services
American Tower Corporation
21307 Rio Oro Dr
Cornelius, NC 28031
704-975-6161 (cell)
From: Generous, Bob [mailto:bgenerous@ci.chanhassen.mn.us]
Sent: Monday, November 16, 2009 11:59 AM
To: Doug Ruwe
Subject: FW: Planning Case 09-19
Doug:
How do you respond to the railroad's statement/request?
:o7
From: Tim Jeske [mailto:TJeske@TCWR.NET]
Sent: Monday, November 16, 2009 10:28 AM
To: Generous, Bob
Cc: Bob Suko; Mark Wegner
Subject: Planning Case 09-19
Robert,
I am writing you in response to your notice pertaining to your planning case # 09-19 / PID: 25-8110240 for
additional radio equipment to be added to an existing tower situated close to TCWR property by Lyman
Boulevard.
While we don't object to the structural element of this project we do have concerns pertaining to potential radio
interference. We use radio communications to control train and maintenance traffic on TCWR and interference
with these radio communications will cause operational and safety issues.
If TCWR gets assurance that this project will not interfere with our current radio system or any future
communication needs we would have no objections to this project.
Tim Jeske
Twin Cites & Western Railroad
CITY OF CHANHASSEN
CARVER AND HENNEPIN COUNTIES, MINNESOTA
AMENDED AND RESTATED
CONDITIONAL USE PERMIT #90-3
PLANNING CASE #09-19
1. Permit. Subject to the terms and conditions set forth herein, the City of Chanhassen
hereby grants an amended and restated conditional use permit for the following use which replaces
Conditional Use Permit 90-3:
A Conditional Use Permit for a 115 -foot tall, telecommunication tower
2. Property. The permit is for property situated in the City of Chanhassen, Carver County,
Minnesota, and legally described as Outlot B, Stone Creek First Addition.
3. Conditions. The permit is issued to American Tower Company and Merle and Jane
Volk subject to the following conditions:
a. The tower and antennas shall comply with the requirements in Chapter 20, Article
XXX, Towers and Antennas of the Chanhassen City Code.
b. A building permit is required for equipment pad and LP gas storage tank pad.
c. A mechanical permit is required for connection (gas piping) of LP storage tank to LP
gas generator.
d. The plans must be signed by appropriate design professionals.
e. No signage, advertising or identification of any kind intended to be visible from the
ground or other structures is permitted, except applicable warning and equipment
information signage required by the manufacturer or by Federal, State, or local
authorities.
4. Severability. In the event any provision of this permit shall be held invalid, illegal, or
unenforceable by any court or competent jurisdiction, such holding shall not invalidate or render
unenforceable any other provision hereof, and the remaining provisions shall not in any way be
affected or impaired thereby.
5. Notices. All notices, certificates and other communications hereunder shall be
sufficiently given and shall be deemed given when mailed by certified mail, returned receipt
requested, postage prepaid, with property address as indicated below. The City and the
Association, by written notice given by one to the other, may designate any address or addresses,
to be sent when required as contemplated by this permit. Unless otherwise provided by the
respective parties, all notices, certificates, and communications to each of them shall be
addressed as follows:
To the City: City of Chanhassen
Attn: City Manager
7700 Market Boulevard
P.O. Box 147
Chanhassen, MN 55317
To the Applicant: American Tower
Attn: Doug Ruwe
21307 Rio Oro Drive
Cornelius, NC 28031
To the Owner: Merle and Jane Volk
16925 County Road 40
Carver, MN 55315
6. Reimbursement of Costs. The Applicant shall reimburse the City for all costs,
including reasonable engineering, legal, planning and administrative expenses incurred by the
City in connection with all matters relating to the administration and enforcement of the within
permit and the performance thereby by the applicant. Such reimbursement shall be made within
fourteen (14) days of the date of mailing of the City's notice of costs as provided in Section 5
above. This reimbursement obligation of the applicant under this section shall be a continuing
obligation throughout the term of this permit.
7. Termination of Permit. The City may revoke the permit following a public hearing for
violation of the terms of this permit. The City may institute any proper action or proceeding at
law or at equity to prevent violations of the within property, to restrain or abate violations of the
within permit, or to prevent use or occupancy of the Subject Property.
8. Lapse. If within one year of the issuance of this permit the authorized construction has
not been substantially completed or the use commenced, this permit shall lapse, unless an extension
is granted in accordance with the Chanhassen Zoning Ordinance.
9. Assignable. This conditional use permit is issued for the particular use and is not
personal. The City shall be notified in writing at the address provided in section 5 above of any
changes in the leasehold interest or ownership of the underlying property at least thirty (30) days
prior to such change.
10. Criminal Penalty. Violation of the terms of this conditional use permit is a criminal
misdemeanor.
Dated: December 14, 2009
CITY OF CHANHASSEN
i]•s
(SEAL)
R_W�71
STATE OF MINNESOTA )
(ss
COUNTY OF CARVER )
Tom Furlong, Mayor
Todd Gerhardt, City Manager
The foregoing instrument was acknowledged before me this_day of , 200_,
by Thomas A. Furlong, Mayor, and by Todd Gerhardt, City Manager, of the City of Chanhassen, a
Minnesota municipal corporation, on behalf of the corporation and pursuant to the authority granted
by its City Council.
NOTARY PUBLIC
DRAFTED BY:
City of Chanhassen
P. O. Box 147
7700 Market Boulevard
Chanhassen, MN 55317
(952)227-1100
............
6t0
SITE PLAN
lY LANDSCAPING ro
o
"J7
LANDSCAPING SCHEDULE
•<
.. .. ..... . .
SITE PLAN
�CHANHAS564�i
W,
til
VICINI"I Y MAP
CITY OF CHANHASSEN
CARVER AND HENNEPIN COUNTIES, MINNESOTA
CONDITIONAL USE PERMIT
1. Permit. Subject to the terms and conditions set forth
herein, the City of Chanhassen hereby grants a conditional use
permit for: Commercial communication transmission tower to
support cellular telephone service.
2. Property. The permit is for the following described
property in the City of Chanhassen, Carver County, Minnesota:
See attached Exhibit A.
3. Conditions. The permit is issued subject to the following
conditions:
1. Staff will approve the aesthetic design of the tower and
building and the building should be consistent with other
recently constructed telephone and public utility buildings in
the area.
2. Staff will approve and document the tower shape and structure
and that it's construction will follow that approval.
3. No other radio uses shall be approved without an addendum to
the conditional use permit #90-3 which will come in before the
Planning Commission and City Council.
4. Landscaping shall be installed as part of the approved
landscaping plan. A letter of credit guaranteeing
improvements will be requiredbefore building permits are
issued.
5. No lights or signage be placed on the tower or elsewhere on
the site.
6. The tower shall be painted a flat color so that it blends in
with the background.
4. Termination of Permit. The City may revoke the permit
following a public hearing under any of the following
circumstances: material change of condition of the neighborhood
where the use is located and/or violation of the terms of this
permit.
5. _Criminal Penalty. Violation of the terms of this
conditional use permit is a criminal misdemeanor.
Date: September 10, 1990
/ 13
7.
,r r�." r 0
Mr. John Uban
September 11, 1990
Page 2
STATE OF MINNESOTA)
) SS
COUNTY OF CARVER )
CITY OF
By:
City Clerk
The oregoing instrument was acknowledged before me this A %�
day of , 19_LU, by Donald J. Chmiel, Mayor and Don
Ashworth, City Clerk of the City of Chanhassen, a Minnesota
municipal corporation, on behalf of the corporation.
Drafted by:
City of Chanhassen
690 Coulter Drive
Chanhassen, MN 55317
(612)937-1900
KAREN J. ENC-ELNAPOT
NOTARY PU9LC - 1"'.. --OTA
CARV011 C)' -:TY
MN 0-a•issim •xr':..-es 10-1691
EXHIBIT A
That part of the Northwest Quarter of Section 22, Township 116,
Range 23, West of the 5th Principal Meridian, Carver County,
Minnesota, which lies southwesterly of a line drawn parallel to and
distant 380 feet northeasterly of the centerline of County Road No.
18, as measured at right angles, and which lies southeasterly of a
line drawn parallel to and distant 395 feet northwesterly of the
centerline of the Chicago, Milwaukee, St. Paul and Pacific
Railroad, as measured at right angles. Except that part taken for
County Road No. 18. Except that part taken for the Chicago,
Milwaukee, St. Paul and Pacific Railroad.
OFFICE OF COUNTY RECORDER
STATE OF MINNESOTA
COUNTY OF CARVER
Filing Fee �-�/U
This is to certify that this docuujnent
w f in tff��.\�office qI. �ttheday
04 M
— f9([A.D.at o'clock
M. and was duly recorded as
document no. 118396
HANS N JR.
unry o er
Dy:
M _BGG_
�3
CITY OF CHANHASSEN
AFFIDAVIT OF MAILING NOTICE
STATE OF MINNESOTA)
) ss.
COUNTY OF CARVER )
I, Karen J. Engelhardt, being first duly sworn, on oath deposes that she is and was on
November 19, 2009, the duly qualified and acting Deputy Clerk of the City of Chanhassen,
Minnesota; that on said date she caused to be mailed a copy of the attached notice of Public
Hearing for Amendment to CUP 90-3 — Planning Case 09-19 to the persons named on
attached Exhibit "A", by enclosing a copy of said notice in an envelope addressed to such owner,
and depositing the envelopes addressed to all such owners in the United States mail with postage
fully prepaid thereon; that the names and addresses of such owners were those appearing as such
by the records of the County Treasurer, Carver County, Minnesota, and by other appropriate
records.
Subscribed and sworn to before me
this lq"day of (inwmh2 i , 2009.
Notary
a KIM T M11WI11EN
Notary Public -Minnesota
M Commission Expires Jan 31, 2010
WvwvvvW
Notice of Public Hearing
Chanhassen Planning Commission Meeting
Date & Time:
Tuesday, December 1, 2009 at 7:00 P.M. This hearing may not
start until later in the evening, depending on the order of theagenda.
Location:
City Hall Council Chambers, 7700 Market Blvd.
Request for an Amendment to Conditional Use Permit 90-3 to
Proposal:
allow co-location/addition of ITT/FAA antennas and radio
Proposal:
equipment at an existing telecommunication tower on property
zoned A ricultural Estate District A2
Applicant:
American Tower Company
Property
2290 Lyman Boulevard (Outlot B, Stone Creek First Addition)
Location:
A location map is on the reverse side of this notice.
The purpose of this public hearing is to inform you about the
applicant's request and to obtain input from the neighborhood
about this project. During the meeting, the Chair will lead the
What Happens
public hearing through the following steps:
at the Meeting:
1. Staff will give an overview of the proposed project.
at the Meeting:
2. The applicant will present plans on the project.
3. Comments are received from the public.
4. Public hearing is closed and the Commission discusses
the project.
If you want to see the plans before the meeting, please visit
the City's projects web page at:
www.ci.chanhassen.mn.us/sery/plan/09-19.html. If you wish to
talk to someone about this project, please contact Robert
Generous by email at bcenerous@ci.chanhassen.mn.us or by
Questions &
phone at 952-227-1131. If you choose to submit written
Comments:
comments, it is helpful to have one copy to the department in
advance of the meeting. Staff will provide copies to the
Commission. The staff report for this item will be available
online on the project web site listed above the Thursday
prior to the Planning Commission meeting.
City Review Procedure:
• Subdivisions, Planned Unit Developments, Site Plan Reviews, Conditional and Interim Uses, Wetland Alterations,
Rezonings, Comprehensive Plan Amendments and Code Amendments require a public hearing before the
Planning Commission. City ordinances require all property within 500 feet of the subject site to be notified of the
application in writing. Any interested party is invited to attend the meeting.
• Staff prepares a report on the subject application that includes all pertinent information and a recommentlation.
These reports are available by request. At the Planning Commission meeting, staff will give a verbal overview of
the report and a recommendation. The item will be opened for the public to speak about the proposal as a part of
the hearing process. The Commission will close the public hearing and discuss the item and make a
recommendation to the City Council. The City Council may reverse, affirm or modify wholly or partly the Planning
Commission's recommendation, Rezonings, land use and code amendments take a simple majority vote of the
City Council except rezonings and land use amendments from residential to commerciallindustrial.
• Minnesota State Statute 519.99 requires all applications to be processed within 60 days unless the applicant
waives this standard. Some applications due to their complexity may take several months to complete. Any
person wishing to follow an item through the process should check with the Planning Department regarding its
status and scheduling for the City Council meeting.
• A neighborhood spokespersoNrepresentative is encouraged to provide a contact for the city. Often developers
are encouraged to meet with the neighborhood regarding their proposal. Staff is also available to review the
project with any interested personms).
• Because the Planning Commission holds the public hearing, the City Council does not. Minutes are taken and
any correspondence regarding the application will be included in the report to the City Council. If you wish to have
something to be included in the report, lease contact the Planning Staff person named on the notification.
Notice of Public Hearing
Chanhassen Planning Commission Meeting
Date & Time:
Tuesday, December 1, 2009 at 7:00 p.m. This hearing may not
start until later in the evening, depending on the order of theagenda.
Location:
City Hall Council Chambers, 7700 Market Blvd.
Request for an Amendment to Conditional Use Permit 90-3 to
allow co-location/addition of ITT/FAA antennas and radio
Proposal:
equipment at an existing telecommunication tower on property
zoned Agricultural Estate District A2
Applicant:
American Tower Company
Property
2290 Lyman Boulevard (Outlot B, Stone Creek First Addition)
Location:
A location map Is on the reverse side of this notice.
The purpose of this public hearing is to inform you about the
applicant's request and to obtain input from the neighborhood
about this project. During the meeting, the Chair will lead the
What Happens
public hearing through the following steps:
1. Staff will give an overview of the proposed project.
at the Meeting:
2. The applicant will present plans on the project.
3. Comments are received from the public.
4. Public hearing is closed and the Commission discusses
the project.
If you want to see the plans before the meeting, please visit
the City's projects web page at:
www.ei.chanhassen.mn.us/serv/plan/09-19.htmi. If you wish to
talk to someone about this project, please contact Robert
Generous by email at bclenerous@ci.chanhassen.mn.us or by
Questions &
phone at 952-227-1131. If you choose to submit written
Comments:
comments, it is helpful to have one copy to the department in
advance of the meeting. Staff will provide copies to the
Commission. The staff report for this Item will be available
online on the project web site listed above the Thursday
prior to the Planning Commission meeting.
City Review Procedure:
• Subdivisions, Planned Unit Developments, Site Plan Reviews, Conditional and Interim Uses, Wetland Alterations,
Rezonings, Comprehensive Plan Amendments and Code Amendments require a public hearing before the
Planning Commission. City ordinances require all property within 500 feet of the subject site to be notified of the
application in writing. Any interested party is invited to attend the meeting.
• Staff prepares a report on the subject application that includes all pertinent information and a recommendation.
These reports are available by request. At the Planning Commission meeting, staff will give a verbal overview of
the report and a recommendation. The item will be opened for the public to speak about the proposal as a part of
the hearing process. The Commission will close the public hearing and discuss the item and make a
recommendation to the City Council. The City Council may reverse, affirm or modify wholly or partly the Planning
Commission's recommendation. Rezonings, land use and code amendments take a simple majority vote of the
City Council except rezonings and land use amendments from residential to commerciaUndustrial.
• Minnesota State Statute 519.99 requires all applications to be processed within 60 days unless the applicant
waives this standard. Some applications due to their complexity may take several months to complete. Any
person wishing to follow an item through the process should check with the Planning Department regarding its
status and scheduling for the City Council meeting.
• A neighborhood spokesperson/representative is encouraged to provide a contact for the city. Often developers
are encouraged to meet with the neighborhood regarding their proposal. Staff is also available to review the
project with any interested personis).
• Because the Planning Commission holds the public hearing, the City Council does not. Minutes are taken and
any correspondence regarding the application will be included in the report to the City Council. If you wish to have
something to be included in the report, lease contact the Plannino Staff person named on the notification.
BRADLEY J & RENEE L VANBERGEN BRIAN N JOHNSON BRIAN T & SONYA A BENKSTEIN
2175 BOULDER RD 2207 BOULDER RD 2292 BOULDER RD
CHANHASSEN MN 55317-7402 CHANHASSEN MN 55317-7400 CHANHASSEN MN 55317-7400
CARL D RAY & SEN ZHAO CHAD A & JULIE M EVEN CHAD K & ROCHELLE E CURTIS
2245 STONE CREEK DR 2198 BOULDER RD 2187 BOULDER RD
CHANHASSEN MN 55317-7420 CHANHASSEN MN 55317-7402 CHANHASSEN MN 55317-7402
CHADW ICK HOUWMAN CHARLENE A STENDER CHASKA CITY
C/O2219 BOULDER RD 2321 BOULDER RD CNOEL ZYK
1ITY HALL
PLAZA
CHANHASSEN MN 55317-7400 CHANHASSEN MN 55317-7401 1 C
CHASKA MN 55318-1962
CHET A LARSON CHRISTOPHER E FINKE & DANIEL J & NANCY R LYNCH
2259 STONE CREEK DR CHRISTINA G FINKE 2255 BOULDER RD
CHANHASSEN MN 55317-7420 2317 BOULDER RD CHANHASSEN MN 55317-7400
CHANHASSEN MN 55317-7401
DAVID HESTER & DELORIS B HOLASEK TRUST
RENEE STEWART-HESTER C/O HOLASEK FARMS LP DOUGLAS VERNON JOHNSON
2199 BOULDER RD2015 STAHLKE WAY 2322 BOULDER RD
CHANHASSEN MN 55317-7402 CHASKA MN 55318-3239 CHANHASSEN MN 55317-7401
EDWARD E & ELLEN L RAWSON GARY L FELDICK & GERHARD & HELENE A SCHOCK
2266 BOULDER RD DONNA G NOVAK 2309 BOULDER RD
CHANHASSEN MN 55317-7400 2231 BOULDER RD CHANHASSEN MN 55317-7401
CHANHASSEN MN 55317-7400
GERHARD G & SALLIE L BERGESON IND SCHOOL DIST 112 JAMES M & JENNIFER D
NAGA
2220 BOULDER RD 11 PEAVEY RD 2318
OULD
B
CHANHASSEN MN 55317-7400 CHASKA MN CHANHASSEN
BOULD55318-2321 ER RD
CHANHASSEN MN 55317-7401
JEFFREY J & KARLA M ALTHOFF
JEFFREY L & GAYLE D SMITH
JEFFREY P & SARAH L WENDORF
2326 BOULDER RD
2279 BOULDER RD
2291 BOULDER RD
CHANHASSEN MN 55317-7401
CHANHASSEN MN 55317-7400
CHANHASSEN MN 55317-7400
MERLE & JANE VOLK
MATTHEW & ROBIN WARDEN
C/O VERIZON WIRELESS
MERLE L & ELIZABETH J OELKE
2308 BOULDER RD
180 WASHINGTON VALLEY RD
2242 BOULDER RD
CHANHASSEN MN 55317-7401
ATTN: NETWORK R
CHANHASSEN MN 55317-7400
BEDMINSTER NJ 07921-2120
MICHAEL & JACQUELINE R MROSKO MICHAEL D & BETTY WRIGHT RAYMOND E &
YAN
2305 BOULDER RD 2280 BOULDER RD 2243 BOULDER
KLDERRD
CHANHASSEN MN 55317-7401 CHANHASSEN MN 55317-7400 CHANHASSEN
BRD RD
CHANHASSEN MN 55317-7400
RICHARD J & CHERYL A HARTMAN ROLAND A STINSKI
TRUSTEES OF C A HARTMAN TRUST C/O SKYLINE BUILDERS INC
2254 BOULDER RD 3647 MCKINLEY ST NE
CHANHASSEN MN 55317-7400 MINNEAPOLIS MN 55418-1599
SCOTT A HANSON &
CHRISTINE A HANSON
2267 BOULDER RD
CHANHASSEN MN 55317-7400
THOMAS M & CAROLYN D THOMSON
2186 BOULDER RD
CHANHASSEN MN 55317-7402
SCOTT T & NICOLE M BRUSH
2301 BOULDER RD
CHANHASSEN MN 55317-7401
RORY D & AMY J LEA
2313 BOULDER RD
CHANHASSEN MN 55317-7401
STEVEN L & JONI L HANSEN
2208 BOULDER RD
CHANHASSEN MN 55317-7400
CHANHASSEN PLANNING COMMISSION
REGULAR MEETING
DECEMBER 1, 2009
Chairwoman Larson called the meeting to order at 7:00 p.m.
MEMBERS PRESENT: Kevin Dillon, Kathleen Thomas, Debbie Larson, Mark Undestad,
Denny Laufenburger, and Dan Keefe
MEMBERS ABSENT: Tom Doll
STAFF PRESENT: Kate Aanenson, Community Development Director; and Bob Generous,
Senior Planner
PUBLIC HEARING:
AMERICAN TOWER CORPORATION: REOUEST FOR AN AMENDMENT TO
CONDITIONAL USE PERMIT #90-3 TO ALLOW CO-LOCATION/ADDITION ON
ITT/FAA ANTENNAS AND RADIO EOIUPMENT AT AN EXISTING
STONE CREEK FIRST ADDITION). APPLICANT: AMERICAN TOWER
CORPORATION, PLANNING CASE NO. 09-19.
Bob Generous presented the staff report on this item.
Larson: Let's start with Kevin tonight.
Dillon: You know I don't have any questions.
Larson: Okay, Kathleen.
Thomas: I don't either.
Larson: Dan.
Keefe: Just one quick one. Is there a limit to what they can put on these towers? I mean can
they just you know continue to add on and they can get, you know by code do we sort of limit
that at all?
Generous: We don't limit the number. It's just that they can't interfere with each other and they
need some separation. So and also a lot of these are line of sight so if they get too low they're
not useful to anyone.
Keefe: Okay. I mean what looks here doesn't you know, seem to be any more. My question is
can get they really kind of crazy?
Planning Commission Meeting — December 1, 2009
Aanenson: Well I think the biggest issue that we typically find is that when they're on the
ground, as a picture that Mr. Generous showed, is that that's very well screened but that's
sometimes when we get some of the complaints is where there's a lot of visual on the ground
also but this is fairly well screened on the ground so it, again we felt like the impact, even if
adding another one would be pretty minimal. And this is one of the taller ones we have in the
city.
Keefe: Yeah, okay. Looks like a warehouse in the background.
Larson: Is that all you have?
Keefe: That's all I have.
Larson: How about you Denny?
Laufenburger: I have two. Who's the owner of the property itself? The property on which this
land, this structure.
Generous: Merle Volk.
Laufenburger: Okay. And just I'm sure there's a logical reason for this. Under the condition
back on, in 1990, condition 3. Let me just read it Bob. No other radio uses shall be approved
without an addendum to the conditional use permit which will come in before the Planning
Commission. What's the logic behind, I mean is there any logic behind which we would not
allow a certain amount of radio wave to be on this antenna for the safety and wellbeing of the
local citizens or just give me some, help me understand that a little bit Bob_
Generous: Well actually we're pre-empted from most of the, our review of these antennas or
telecommunication antennas on that. We do look at how safety issues. We haven't had a
problem with electromagnetic waves from these antennas. I should point out that we did have
one resident to the north of it called and said she was opposed to the amendment, but other than
that we haven't had any problems or interference with any radio signals due to this facility. I
wonder, the applicant may have additional comments on that.
Aanenson: I would just add too. Prior, this was put in place prior to the City adopting an
ordinance and that ordinance that we have is a model ordinance that's applied with the new, as
Bob indicated, the regulations, so it does take into consideration some of those things that you
talked about. The frequency. The reason this was put in place for it to have to come back, there
was no standards in place. The City didn't really have them and now they're effective statewide,
federal standards as far as those types of regulations.
Laufenburger: You mentioned that one resident opposed. Was there a reason given to why they
were opposed to this?
Generous: They just said it was an unsightly tower.
a�,:; AU
Planning Commission Meeting — December 1, 2009
Laufenburger: Okay.
Generous: I told her that even if you denied this amendment they would still keep the tower and
the antennas on it so you're not voiding.
Larson: Can we do like they do in California and turn them into like pine trees and palm trees.
Have you seen those?
Aanenson: Well yeah, we've looked at those in some other locations. Actually some of the
mono poles that we've done, this is really one of the few ones that's, most of the ones we do now
are the mono poles where they must.
Laufenburger: Single, yeah.
Aanenson: Correct.
Laufenburger: Like the one at Halla Nursery, down in that area?
Aanenson: Correct. Again the discretion we have on those and now spelled out in the model
ordinance that the government has spelled out that we can, can and cannot regulate but this again
is the older type model so it's a little bit different. It's, obviously the bulk makes it, the
appearance less attractive.
Laufenburger: Okay. Then one last question. Bob you used the term we are pre-empted from
regulating or from reviewing this. What did you mean by that?
Generous: Well not from reviewing it per se but the federal government has stated that the local
governments, must approve it if it complies with their communication acts.
Laufenburger: Okay. Alright. Thank you Chairman.
Larson: Nothing? And I have nothing also. So at this time have we got an applicant?
Christopher Flick: Good evening ladies and gentlemen. My name is Christopher Flick. I am
with American Tower Corporation. I'm representing, I work with American Tower. We are the
owners of the actual tower itself and own lease rights to the property. We are working with ITT
and the FAA to provide an ADS -B system. The ADS -B system is an automatic dependent
surveillance and broadcast system. Basically it's designed to monitor lower flying planes
throughout the United States. This is a national program instituted by the FAA in order to
provide a greater and more enhanced aspect, like radar of lower flying aircraft. Helicopter
aircraft.
Larson: So do they dial into that?
Christopher Flick: It's, yes. Basically. It runs through a high speed network. Without being
you know an engineer myself all I can say for sure is that the system is designed to help prevent
Planning Commission Meeting — December 1, 2009
the, as Bob had mentioned, line of sight works basically the same thing with this type of system
as it does with regular RF for your cell phone. The radars on the ground that the airports use and
they're spotted around the country, can only see a certain distance to the horizon. This system
will provide a closer to the ground view of air traffic so the idea is to see more of what's going
on over our heads rather than guessing up to a certain height. The tower itself is a lattice tower
and to speak to the councilman's question about the tower itself. There are structural
requirements. They can't just keep on, you know it's my tower so we can't just keep on
throwing stuff up there. There's a certain tolerance and the only way to do the structural
calculations and decide whether or not somebody can go on the tower is to have an engineering
firm do those calculations. Weigh sale space which is the amount of space that the air hits the
appertances on the tower. The weight of the coax. The weight of the antenna. It's a very
detailed formula that's done prior to an application coming to the board so that would actually
prevent the...
Aanenson: That's the same process we would use if we were going to lease out one of our city
towers. We'd do the same exercise. And I just want to comment a little bit about the
surveillance. If you look at the National Weather Service, some of the things that they do, they
also do aeronautics there and they also shoot up the gamma rays for the weather service to check
weather service so we do have that already in town already. That same type of technology.
Larson: Okay, got any questions? No? No? Nor do I. Thank you very much.
Christopher Flick: Thank you for the board's time.
Larson: At this time I will open the public hearing. If anybody wants to come up here. Seeing
that nobody's here, we will not close the public hearing and discuss it amongst ourselves.
Undestad: Looks fine with me.
Laufenburger: Good to go.
Keefe: I'm good.
Thomas: Me too.
Dillon: I'm good, plus there's a lack of public outcry and opposition to this so you know, it
doesn't seem like any of the neighbors.
Larson: Aren't here tonight. I'm good for it too so with that I will entertain a motion.
Undestad: I'll make a motion. The Planning Commission recommends approval of Conditional
Use Permit #09-19 amending Conditional Use Permit #90-03 to permit co -location and addition
of antennas and equipment upon and at the existing telecommunication tower plans prepared by
Advanced Engineering and Sciences dated 10/23/09, subject to conditions 1 through 5.
Larson: Have we got a second?
4
Planning Commission Meeting — December 1, 2009
Laufenburger: Second.
Undestad moved, Laufenburger seconded that the Planning Commission recommends the
City Council approve Conditional Use Permit #09-19, amending the Conditional Use
Permit #90-03 to allow co-location/addition of antennas and radio equipment upon and at
the existing telecommunications tower, plans prepared by Advanced Engineering and
Science dated 10/23/09, subject to the following conditions and adoption of the attached
Findings of Fact and recommendations:
The tower and antennas shall comply with the requirements in Chapter 20, Article XXX,
Towers and Antennas, of the Chanhassen City Code.
2. A building permit is required for equipment pad and LP gas storage tank pad.
3. A mechanical permit is required for connection (gas piping) of LP storage tank to LP gas
generator.
4. The plans must be signed by appropriate design professionals.
5. No signage, advertising or identification of any kind intended to be visible from the
ground or other structures is permitted, except applicable warning and equipment
information signage required by the manufacturer or by Federal, State, or local
authorities.
All voted in favor and the motion carried unanimously with a vote of 6 to 0
APPROVAL OF MINUTES: Commissioner Thomas noted the verbatim and summary
minutes of the Planning Commission meeting dated November 17, 2009, amended by
Chairwoman Larson to change the word "storm" to "store" on page 11, paragraph 8.
COMMISSION PRESENTATIONS. None.
CITY COUNCIL ACTION UPDATE
Aanenson: I'll just give council updates before we go to the work session portion of it. At the
last City Council meeting, which was November 23`a, the City Council did table the Gleason
variance and encouraged the owner of the property, working with Lennar to try to resolve the
hard surface coverage so they did table that. They did approve the City Code amendments. Just
as the Planning Commission did. And then they also approved preliminary plat for the transit
station. It will be going back for final plat here on the 10 of December so that should be, and
I'll just segue into kind of what's coming up on the next agenda. We did put the schedule
together for the year, including some work session dates and then a couple meetings where
we've tried not to conflict with National Night Out. Then in the fall no meeting on the election
night. We do have a couple projects that we will be having coming in. We've identified those
potential or commercial one. We talked about the park and ride. You've seen that but that'll be
5
Planning Commission Meeting — December 1, 2009
coming through. We also do have a couple residential projects that will be coming in.
Anticipate one coming in this Friday so you'll see that in your First meeting in January. That's
that Lakeside PUD which was, just on the other side of the park and ride, down off of Lyman
Boulevard. So we'll have to amend that PUD. Then we're going to do some of the commercial
ones which I'll segue to here in a minute when we move into the work session. If you want to
adjourn then we can just kind of move into the work session part, unless you have any questions.
Chairwoman Larson adjourned the Planning Commission meeting at 7:15 p.m.
Submitted by Kate Aanenson
Community Development Director
Prepared by Nann Opheim
0
CITY OF CHANHASSEN
CARVER & HENNEPIN
COUNTIES
NOTICE OF PUBLIC HEARING
PLANNING CASE NO. 09-19
NOTICE IS HEREBY GIVEN
that the Chanhassen Planning
Commission will hold a public
hearing on Tuesday, December 1,
2009, at 7:00 p.m. in the Council
Chambers in Chanhassen City Hall,
7700 Market Blvd. The purpose of
this hearing is to consider a request
for an Amendment to Conditional
Use Permit 90-3 to allow co -location/
addition of fl"P/FAA antennas and
radio equipment at an existing
telecommunication tower on
property zoned Agricultural Estate
District A2 and located at 2290
Lyman Boulevard (Outlot B, Stone
Creek First Addition). Applicant:
American Tower Company
A plan showing the location of the
proposal is available for public
review on the City's web site at
www.rj&h&nhassen.mn.us/serv/
olan/09-19.html or at City Hall
during regular business hours.
All interested persons are invited
to attend this public hearing and
express their opinions with
respect to this proposal.
Robert Generous,
Senior Planner
Email:
bgenerous&i.chanhassen.mn.us
Phone: 952-227.1131
(Published in the Chanhassen
Villager on Thursday, November
19,2009; No. 4281)
Affidavit of Publication
Southwest Newspapers
State of Minnesota)
)SS.
County of Carver )
Laurie A. Hartmann, being duly swom, on oath says that she is the publisher or the authorized
agent of the publisher of the newspapers known as the Chaska Herald and the Chanhassen Vil-
lager and has full knowledge of the facts herein stated as follows:
(A) These newspapers have complied with the requirements constituting qualification as a legal
newspaper, as provided by Minnesota Statute 331 A.02, 331 A.07, and other applicable laws, as
amended. t
(B) The printed public notice that is attached to this Affidavit and identified as No. V d1T 1
was published on the date or dates and in the newspaper stated in the attached Notice and said
Notice is hereby incorporated as part of this Affidavit. Said notice was cut from the columns of
the newspaper specified. Printed below is a copy of the lower case alphabet from A to Z, both
inclusive, and is hereby acknowledged as being the kind and size of type used in the composition
and publication of the Notice:
abcdefghijklmnopgrstuvw�x/y�z
Laurie A. Hartman
Subscribed and sworn before me on
this day of t ✓ 2009
JVMME J. BARK
v NOTARY PUBUC - MINNESOTA
No blic My Commission Expires 01/31/2013
RATE INFORMATION
Lowest classified rate paid by commercial users for comparable space.... $31.20 per column inch
Maximum rate allowed by law for the above matter ................................ $31.20 per column inch
Rate actually charged for the above matter ............................................... $12.43 per column inch
SCANNED
PROJECT NAME:
ITTSV173-21 Colocation
LOCATION: 2290 Lyman Rd, Chanhassen, MN 55317
LEGAL DESCRIPTION AND PID: 94-3213132
TOTALACREAGE:
WETLANDS PRESENT: YES X NO
PRESENTZONING: Commercial
REQUESTED ZONING: Commercial - amend CUP 90-3
PRESENT LAND USE DESIGNATION:
REQUESTED LAND USE DESIGNATION:
REASON FOR REQUEST: To allow the colocation/addition of ITT/FAA antennas
and radio equipment at an existing telecommunication tower.
FOR SITE PLAN REVIEW: Include number of existing employees: " and new employees:
This application must be completed in full and be typewritten or clearly printed and must be accompanied by all information
and plans required by applicable City Ordinance provisions. Before filing this application, you should confer with the
Planning Department to determine the specific ordinance and procedural requirements applicable to your application.
A determination of completeness of the application shall be made within 15 business days of application submittal. A written
notice of application deficiencies shall be mailed to the applicant within 15 business days of application.
This is to certify that I am making application for the described action by the City and that I am responsible for complying with
all City requirements with regard to this request. This application should be processed in my name and I am the party whom
the City should contact regarding any matter pertaining to this application. I have attached a copy of proof of ownership
(either copy of Owner's Duplicate Certificate of Title, Abstract of Title or purchase agreement), or I am the authorized person
to make this application and the fee owner has also signed this application.
I will keep myself informed of the deadlines for submission of material and the progress of this application. I further
understand that additional fees may be charged for consulting fees, feasibility studies, etc. with an estimate prior to any
authorization to proceed with the study. The documents and information I have submitted are true and correct to the best of
my knowledge.
Signature of Applicant
��a yo-� V '��
Signature of Fee Owner
GiplanVorms0evelopment Review Applimtion.DOC
Date
a- 4- o 2�
Date
Rev. 1108
SCANNED
CITY OF C
P O BOX 1
CHANHASSE
12/03/20C
Receipt r
CLERK: ka
PAYEE:
Planning
GIS List
Total
Cash
Check
Change
SCANNED
' CHECK NO. 239531
DATE 02 -DEC -09 VENDOR NAME CITY OF CHANHASSEN VENDOR NO. 76563
INVOICE
NUMBER
INVOICE
DATE
PO NUMBER
DESCRIPTION
GR AMOUNT
DISCOUNT
NET AMOUNT
12.02.2009
02 -DEC -09
166755
166755
111.00
0.00
111.00
I
I
PLEASE DETACH AND RETAIN THIS STATEMENT AS YOUR RECORD OF PAYMENT
111.00
0.00
111.00
SCANNED
City of Chanhassen
7700 Market Boulevard
P.O. Box 147
Chanhassen, MN 55317
CfiOF (952) 227-1100
CHMSEH
To: Mr. Doug Ruwe
American Tower Corporation
21307 Rio Oro Drive
Cornelius, NC 28031
Invoice
SALESPERSON
DATE
TERMS
KTM
11/19/09
upon receipt
111W
37 1 Property Owners List within 500' of 2290 Lyman Blvd. (37 labels)
TOTAL DUE
$3.00 1 $111.00
$111.00
NOTE: This invoice is in accordance with the Development Review Application submitted to the City by the
Addressee shown above (copy attached) and must be paid prior to the public hearing scheduled for
December 1, 2009.
Make all checks payable to: City of Chanhassen
Please write the following code on your check: Planning Case #09-19.
If you have any questions concerning this invoice, call: (952)-227-1107.
THANK YOU FOR YOUR BUSINESS!
CITY OF CHANHASSEN
PROPOSED MOTION:
PC DATE: December 1, 2009 ❑
CC DATE: December 14, 2009
REVIEW DEADLINE: December 29, 2009
CASE #: 09-19
BY: AF, RG, JM, JS
"The Chanhassen Planning Commission recommends that City Council approve the amendment to
Conditional Use Permit 90-3 to allow co-location/addition of antennas and radio equipment upon and
at the existing telecommunication tower, plans prepared by Advanced Engineering and Science dated
10/23/09, subject to conditions 1 - 5 and adoption of the attached findings of fact and
recommendations.,,
SUMMARY OF REQUEST: The developer is requesting an amendment to Conditional Use
Permit 90-3 to allow co-location/addition of ITT/FAA antennas and radio equipment at an existing
telecommunication tower.
LOCATION: 2290 Lyman Boulevard (Outlot B, Stone Creek First Addition)
APPLICANT: American Tower Company OWNER: Merle and Jane Volk
PRESENT ZONING: Agricultural Estate District, A-2
2020 LAND USE PLAN: Residential — Low Density
ACREAGE: DENSITY: Not applicable
LEVEL OF CITY DISCRETION IN DECISION-MAKING:
The City has limited discretion in approving or denying conditional use permits, based on
whether or not the proposal meets the conditional use permit standards outlined in the Zoning
Ordinance. If the City finds that all the applicable conditional use permit standards are met, the
permit must be approved. This is a quasi-judicial decision.
PROPOSAL/SUMMARY
The applicant is requesting an
amendment to Conditional Use
Permit 90-3 to allow co-
location/addition of antennas and
equipment upon and at an
existing telecommunication
tower.
To the north of the site are
single-family homes on property
zoned RSF located within the
Planning Commission
American Tower Corporation CUP
December 1, 2009
Page 2 of 5
Stone Creek subdivision. To the east are the Twin Cities & Western Railroad and the athletic fields
for Chanhassen High School. To the south across Lyman Boulevard is industrial development in
the City of Chaska. To the west are farm fields associated with Holasek Nursery.
When the communication tower was originally approved, cellular communication was a fairly new
technology. Additionally, the only standards the City had at the time was that the use was a
conditional use in the Agricultural Estate District, the general CUP issuance standards and the
requirement that towers be setback from the property line a minimum of the height of the tower or
the tower must be self -collapsing.
Since the original CUP approval, the City has
adopted an entire section of the Code that addresses
Tower, and Antennas, Chapter 20, Article XXX.
These standards permit a reasonable and equitable
opportunity for the establishment of
telecommunication services, ensure that towers and
antennas are designed and constructed in a manner
that does not adversely impact public safety
(height, setback and construction standards),
maximize the use of existing and approved towers
and buildings for antennas in order to reduce the
number of towers required (co -location) and
minimize adverse visual effects of towers through careful design and siting standards.
and proposed use of the site for telecommunication purposes complies with these requirements.
The existing
Staff is recommending approval of the amendment to the CUP to permit the co -location of
antennas and equipment at the existing tower site.
APPLICABLE REGUATIONS
Chapter 20, Article IV, Conditional Uses
Section 20-572 (2), Permitted Uses in the "A-2" Agricultural Estate District — Antennas
20-574 (15), Conditional Uses in the "A-2" Agricultural Estate District — Towers
Chapter 20, Article XXX, Towers and Antennas
Conditional Use Permit #90-3
On September 10, 1990, the Chanhassen City Council approved a conditional use permit for a
commercial communication transmission tower to support cellular telephone service. The
conditions of approval were as follows:
1. Staff will approve the aesthetic design of the tower and building and the building should be
consistent with other recently constructed telephone and public utility buildings in the area.
Y
Planning Commission
American Tower Corporation CUP
December 1, 2009
Page 3 of 5
2. Staff will approve and document the tower shape and structure and that it's construction will
follow that approval.
3. No other radio uses shall be approved without an addendum to the
conditional use permit #90-3 which will come in before the
Planning Commission and City Council.
4. Landscaping shall be installed as part of the approved landscaping
plan. A letter of credit guaranteeing improvements will be required
before building permits are issued.
5. No lights or signage be placed on the tower or elsewhere on the
site.
6. The tower shall be painted a flat color so that it blends in with the
background.
Recorded on October 5, 1990 as document number 118396.
Subdivision #92-1
On February 22, 1993, the Chanhassen City Council approved the final plat for Stone Creek First
Addition, creating Outlot B. The tower was already located on the parcel at the time of platting.
ANALYSIS
A building permit is required for equipment pad and
LP gas storage tank pad. A mechanical permit is
required for connection (gas piping) of LP storage
tank to LP gas generator. The plans must be signed
by appropriate design professionals.
The plans submitted show proposed improvements
within the existing pad located north of Lyman
Boulevard between Galpin Boulevard and the
railroad tracks. The applicant does not propose to
expand the existing impervious surface. There is no
grading proposed.
Since the tower already exists, the City would normally review the proposed additional
equipment and tower through the building permit process. However, due to condition 3 of CUP
#90-3, the equipment and antenna must be approved through the public hearing process. Staff is
proposing that the conditions of approval be amended to require compliance with the City Code
standards for towers and antennas which would encourage and permit the co -location of antennas
and equipment at and upon the existing tower.
1
'v
RV
-T
:-v
Since the tower already exists, the City would normally review the proposed additional
equipment and tower through the building permit process. However, due to condition 3 of CUP
#90-3, the equipment and antenna must be approved through the public hearing process. Staff is
proposing that the conditions of approval be amended to require compliance with the City Code
standards for towers and antennas which would encourage and permit the co -location of antennas
and equipment at and upon the existing tower.
Planning Commission
American Tower Corporation CUP
December 1, 2009
Page 4 of 5
GENERAL CONDITIONAL USE PERMIT
The applicant is requesting an amendment to the Conditional Use Permit to permit the co -
location of antennas and equipment on the existing tower. The City's Zoning Ordinance allows
telecommunication towers and antennas in Agricultural Estate Districts subject to the approval of
a conditional use permit by the City Council. In reviewing conditional use permit requests, the
Planning Commission must consider possible adverse affects of the use.
The City of Chanhassen finds it necessary for the promotion and preservation of the public
health, safety, welfare, and aesthetics of the community that the construction, location, size, and
maintenance of wireless telecommunication facilities be controlled. Further, the City finds:
1. Towers and antennas have a direct impact on, and a relationship to,
the image of the community;
2. The manner of installation, location, and maintenance of towers and
antennas affects the public health, safety, welfare, and aesthetics of
the community;
A reasonable opportunity for the establishment of wireless
telecommunication must be provided to serve residential and business
needs, and;
4. Uncontrolled and unlimited towers and antennas adversely impact the
image and aesthetics of the community and, thereby, undermine
economic value and growth.
Given that it is the City's goal is to minimize towers, the amendment of
the CUP to permit co -location of antennas and equipment is appropriate.
COMPLIANCE
Height Setback
Code 150* Structureheight
American Tower 115 175 feet
*May be increased 25 feet for multi -antenna towers.
RECOMMENDATION
Staff recommends that the Planning Commission adopt the following motion and adoption of the
attached findings of fact and recommendation:
Planning Commission
American Tower Corporation CUP
December 1, 2009
Page 5 of 5
"The Planning Commission recommends approval of Conditional Use Pen -nit #09-19, amending
Conditional Use Permit 90-03, to permit co-location/addition of antennas and equipment upon and
at the existing telecommunication tower, plans prepared by Advanced Engineering & Sciences,
dated 10/23/09, subject to the following conditions:
1. The tower and antennas shall comply with the requirements in Chapter 20, Article XXX,
Towers and Antennas, of the Chanhassen City Code.
2. A building permit is required for equipment pad and LP gas storage tank pad.
3. A mechanical permit is required for connection (gas piping) of LP storage tank to LP gas
generator.
4. The plans must be signed by appropriate design professionals.
5. No signage, advertising or identification of any kind intended to be visible from the ground
or other structures is permitted, except applicable warning and equipment information
signage required by the manufacturer or by Federal, State, or local authorities."
ATTACHMENTS
1. Findings of Fact and Recommendation.
2. Development Review Application.
3. Reduced copy of Compound Plan Sheet 3 of 18.
4. Reduced Copy Tower Profile Sheet 4 of 18.
5. Letter from Doug Ruwe to City of Chanhassen Dated October 29, 2009.
6. Permit Authorization by TIT Corporation.
7. Letter from Richard L. Day to Greg Hughes dated January 2, 2008.
8. Email Correspondence between Tim Jeske, Bob Generous and Doug Ruwe between
November 16 and November 18, 2009.
9. Amended and Restated Conditional Use Permit.
10. Reduced Copy Site Plan Dated 7-16-90.
11. Conditional Use Permit 90-3 dated September 10, 1990.
9:W-\2009 Planning Cas 09-19 american town cup 90.3 a mendmeMkmff'epwt americao tower -dm
C1TY OF CHANHASSEN
CARVER AND HENNEPIN COUNTIES, MINNESOTA
FINDINGS OF FACT
AND RECOMMENDATION
Application of American Tower and Merle and Jane Volk for an amendment to the existing
Conditional Use Permit 90-3 to permit the installation of additional antennas and equipment at
and upon an existing telecommunication tower.
On December 1, 2009, the Chanhassen Planning Commission met at its regularly
scheduled meeting to consider the application of American Tower and Merle and Jane Volk for
an amendment to a conditional use permit to permit a telecommunication tower for the property
located at 2290 Lyman Boulevard. The Planning Commission conducted a public hearing on the
proposed conditional use was preceded by published and mailed notice. The Planning
Commission heard testimony from all interested persons wishing to speak and now makes the
following:
FINDINGS OF FACT
The property is currently zoned Agricultural Estate District, A-2.
2. The property is guided by the Land Use Plan for Residential — Low Density.
3. The legal description of the property is: Outlot B, Stone Creek First Addition.
4. Conditional Use Permits
a. The proposed use will not be detrimental to, but may enhance the public health,
safety, comfort, convenience or general welfare of the neighborhood or the city. The
proposed tower will provide a basic utility to the area.
b. The proposed use will be consistent with the objectives of the city's comprehensive
plan and this chapter.
c. The proposed use will be designed, constructed, operated and maintained so to be
compatible in appearance with the existing or intended character of the general
vicinity and will not change the essential character of that area. The proposed tower
complies with city ordinance requirements. The lower portion of the tower including
the equipment will be screened by vegetation and a berm.
d. The proposed use will not be hazardous or disturbing to existing or planned
neighboring uses.
CITY OF CHANHASSEN
7700 Market Boulevard — P.O. Box 147
Chanhassen, MN 55317 — (952) 227-1100
DEVELOPMENT REVIEW APPLICATION
nt Name and Address:
Ruwe - American Tower
21307 Rio Oro Dr
Cornel ins, NC 260"1
Contact:
Phone: 704-975-6161 Fax:
Email: oug.ruwe@americantower.com
Planning Case No. 0cl I
)wner Name and Address:
Merle & Jane Volk
16925 Countv RD 40
CITY OF CHANHASSEN
RECEIVED
OCT 3 0 2009
CHANHASSEN PLANNING DEPT
Carver MN S5"ll S
Contact:
Phone: Fax:
Email:
NOTE: Consultation with City staff is required prior to submittal, including review of development
plans
Comprehensive Plan Amendment
X Conditional Use Permit (CUP) tL_i
Interim Use Permit (IUP)
Non -conforming Use Permit
Planned Unit Development*
Rezoning
Sign Permits
Sign Plan Review
Site Plan Review (SPR)'
Subdivision'
Temporary Sales Permit
Vacation of Right-of-Way/Easements (VAC)
Variance (VAR)
Wetland Alteration Permit (WAP)
Zoning Appeal
Zoning Ordinance Amendment
X Notification Sign $200
(City to install and re ove)
X Esc Filing Fees/Attorney Cost"
50 CUP SPR/VACNAR/WAP/Metes & Bounds
$45U -Minor SUB
TOTAL FEE $ IY� G9 C',F(�oc-I
An additional fee of $3.00 per address within the public hearing notification area will be invoiced to the applicant
prior to the public hearing.
"Sixteen (16) full-size folded copies of the plans must be submitted, including an 8'/2" X 11"
reduced copy for each plan sheet along with a digital copy in TIFF -Group 4 ('.tif) format.
"Escrow will be required for other applications through the development contract.
'uilding material samples must be submitted with site plan reviews.
)TE: When multiple applications are processed, the appropriate fee shall be charged for
h application.
SCANNED
e. The proposed use will be served adequately by essential public facilities and services,
including streets, police and fire protection, drainage structures, refuse disposal, water
and sewer systems and schools; or will be served adequately by such facilities and
services provided by the persons or agencies responsible for the establishment of the
proposed use.
f. The proposed use will not create excessive requirements for public facilities and
services and will not be detrimental to the economic welfare of the community. It
will provide a necessary utility.
g. The proposed use will not involve uses, activities, processes, materials, equipment
and conditions of operation that will be detrimental to any persons, property or the
general welfare because of excessive production of traffic, noise, smoke, fumes, glare,
odors, rodents, or trash. The tower should not create conditions that are detrimental
to person's property or the general welfare of the community.
h. The proposed use will have vehicular approaches to the property which do not create
traffic congestion or interfere with traffic or surrounding public thoroughfares.
i. The proposed use will not result in the destruction, loss or damage of solar access,
natural, scenic or historic features of major significance.
j. The proposed use will be aesthetically compatible with the area.
k. The proposed use will not depreciate surrounding property values.
1. The proposed use will meet standards prescribed for communication towers as
provided in zoning ordinance.
5. The Planning Report #09-19 dated December 1, 2009, prepared by Robert Generous, et
al, is incorporated herein.
RECOMMENDATION
The Planning Commission recommends that the City Council approve the amendment to
the conditional use permit for a telecommunication tower.
ADOPTED by the Chanhassen Planning Commission this 0 day of December, 2009.
CHANHASSEN PLANNING COMMISSION
M
Its Chairman
I .
2.
3.
..
3.
6.
7.
B.
B.
COMPOUND NOTES
RDDIO: EXCLUOIND ME TOWER. NO EXISUND OR PROPOSED
miirmler IIWItImmc EOUIPNOM WILL E)CEED THE HEICH!
WIND SPACE IS REQUIRED. ONE ENISGNG.
OR SIGNS ME NOT PROPOSED EXCEPT AS
E PCC.
ONRROL: THE PROPOSED PK.RM WILL RESULT IN
f INCREASE IN STORM WATER RUNOIT.
NO WATER OUN.IM1 PAMROL DIMCES ARE
)F—WAY OR
WILL RESULT
COMPOUND VIEW
20' A 100' PARD ACCESS MIA
A COMPOUND PLAN
SGLLE:1'�S' (BASED ON 24%38 'D' PAPER SIM
SCALE: 1' 10' (BASED ON IIX17 'B' PAPER SIZE)
m
PAN
Im ITT
D GALLON IE TANK
em a July
pMWPY PP
Am,a«d 81388
�_� 9M715
dWNNYN..YC
NOTE:
SEE PROPOSED ICE BRIDGE, SHEET 9 433961K3 D 2
m3. 1B wxE
dlfl
PROJECT NAME:
KS:ai`� �f4:2 A
ITTSVI73-21 Colocation
2290 Lyman $d', Chanhassen, MN 55317
LEGAL DESCRIPTION AND PID: X32 c15 —S I � CJaLbz)
TOTAL ACREAGE:
WETLANDS PRESENT: VES X NO
PRESENT ZONING:
Commercial
REQUESTED ZONING: Commercial - amend CUP 90-3
PRESENT LAND USE DESIGNATION:
REQUESTED LAND USE DESIGNATION:
REASON FOR REQUEST: To allow the colocation/addition of ITT/FAA antennas
and radio equipment at an existing telecommunication tower.
FOR SITE PLAN REVIEW: Include number of existing employees:
and new employees:
This application must be completed in full and be typewritten or dearly printed and must be accompanied by all information
and plans required by applicable City Ordinance provisions. Before filing this application, you should confer with the
Planning Department to determine the specific ordinance and procedural requirements applicable to your application.
A determination of completeness of the application shall be made within 15 business days of application submittal. A written
notice of application deficiendes shall be mailed to the applicant within 15 business days of application.
This is to certify that I am making application for the described action by the City and that I am responsible for complying with
all City requirements with regard to this request. This application should be processed in my name and I am the party whom
the City should contact regarding any matter pertaining to this application. I have attached a copy of proof of ownership
(either copy of Owner's Duplicate Certificate of Title, Abstract of Title or purchase agreement), or I am the authorized person
to make this application and the fee owner has also signed this application.
I will keep myself informed of the deadlines for submission of material and the progress of this application. I further
understand that additional fees may be charged for consulting fees, feasibility studies, etc. with an estimate prior to any
authorization to proceed with the study. The documents and information I have submitted are true and correct to the best of
my knowledge.
mature of Applicant Date
lure of Fee Owner Date
ms0evelopmenl Review Applic tion.DOC Rev. 1/08
SCANNED
A
AMERICANTOWER'
CO R PO R A T 1 OM
October 29, 2009
City of Chanhassen
Community Development — Bob Generous
7700 Market Boulevard, PO Box 147
Chanhassen, MN 55317
RE: ITTSV 173-07 ITT FAA Collocation
American Tower Site Code: 305556
2922 Hibbard Rd
Parcel Number 11-04-200-003
CITY OF SEN
RECENED
OCT 3 0 2009
CHANNASSEN PLANNING DEPT
As we discussed, enclosed please find: City of Chanhassen Development Review Application to amend CUP90-3,
(2) letter of authorization (ITT/FAA), copy a stamped construction drawings for ITTSV 173-21, a stamped structural
analyses, and a check for $675.00 for the review fee for the zoning your review. Hopefully we can still make the
December meeting agendas.
Specifically, ITT is applying for zoning and building permits to collocate six (6) antennas and coaxial limes on the
existing tower referenced above. They will also be installing a radio equipment cabinet, an emergency back-up
diesel generator on a new concrete pad within the existing fenced compound. The tower will not increase in height
and the compound will not increase in size due to the installation. The purpose of this collocation is the replacement
of the existing FAA air navigation system. Once implemented, this new technology will greatly enhance the safety
of the traveling public in all types of aircraft The total job cost is expected to be $30,000.00.
At this time American Tower has not selected a contractor, but once the use has been approved and the fees
determined, we will have the general contractor complete the building permit applications and pay any outstanding
fees. Please let me know if the material provided is deficient, or if you need any additional information. Should you
have any questions please contact me at (704) 975-6161 or by e-mail doug ruwe(&americantower.com.
American Tower greatly appreciates your assistance with this permit request
Sincerely,
Doug Ruwe
Project Manager Site Development
(704)975-6161
doug.ruwe@AmericanTower.com
Enclosures
21307 No Oro Dr • Cornelius NC 26031 • (704) 975-6161 • doug.ruwe@americantower.com
SCANNED
1. SEE GNAWING SHEET 3 FOR COMPOUND PUN.
2. ALL TIORWED S[RUCNRAL FASTENERS FOR ANTENNA
SUPPORT ASSEMBLIES SNALL CCAIMRM TO ASTM A307
OR ASTM Mt ALL STRUCTURAL FASTENERS FOR
STRUCTURAL HEEL FRAMING SIA L CONFORM TO ASTM
A125. FASTENERS SHALL BE 5/B MIN. DU, SWING
TYPE CONNECTIONS WITH THREADS EXCLUDED FOR THE
PLANE. ALL EXPOSED FASTENERS, NNS. AND WASHERS
SHALL BE GALVANIZED UNLESS OTHERWISE NOTED.
CONCRETE EXPANSION ANCHORS SHALL BE HILTI NWIR
BOLTS UNLESS OTHERWISE NOTED. ALL ANCHORS INTO
CONCRETE SHALL BE STAINLESS STEEL.
3. THE GENERAL CONTRACTOR/SUB CONTRACTOR SHALL
FURNISH ALL CONNECTON HARDWARE REOURED TO
SECURE THE CABLES. CONNECTION HARDWARE aHLLL
BE STAINLESS STEEL
A. NORTH ARROW SHOWN ON THE PIANS REFERS TO
TRUE NORM. THE GENERAL CONTRACTOR UB CONTACTOR
SHALL VERIFY NORTH AND NOTIFY RT C RP/TBD OF
ANY DISCREPANCY BEFORE STARTING CONSTRUCTION.
5. PROADE LOCK WASHERS FOR ALL MECMANIGL
CONNECTIONS FOR GROUNDING CONDUCTORS, WE
STNNLESS STEEL HARDWARE THROUGHOUT,
6. THOROUGHLY RCIAM ALL PANT AND CLEW ALL
DIRT FROM SURFACES REQUIRING GROUND CONNECTIONS
7. AV(E ALL GROUND CONNECTIONS AS SHORT AND
DIRECT AS POSSIBLE AVOID SHARP BENDS. ALL BENDS
TO BE A MIN. OF B' RADIUS.
8. FON GROUNDING TO BUILDING FRAME AND HATCH
PUTS GROUND BARS. USE A TWO -BOLT HOLE NEW
DRILLED CONNECTOR SUCH AS A TBB 32007 OR
AN APPROVED EQUAL PART.
B. FOR ALL EXTERNAL GROUND CONNECTIONS. CLAMPS
AND CADWELDS, APPLY A LIBERAL PROTECTNE COATING
OR AN ARI -OXIDE COMPOUND SUCH AS 'NO-OXWE A'
BY DFAABORN CHEMICAL COMPANY.
10. REPAR ALL GALVANIZED SURFACES THAT NAVE BEEN
COMMUNED BY THERMOWELDINO WITH COLD GLLV. PAM.
11. SEAL ALL CONDUITS PENETRATIONS INTO STRUCTURES
AND ALL CONDUIT OPENINGS WITH A SILICONE SEALANT.
12, THE COAXAL ANTENNA CABLE INSTALLER SNALL BE
RESPONSIBLE FOR PERFORMING AND SUPPLYING SWEEP
TESTS (ANTENNA RETURN LOSS TEST). THIS TEST SMALL BI
PERFORMED TO ME SPECIFICATIONS AND PARAMETERS
OUNINED BY THE IT CORP. RADIO FREQUENCY INK
ENGINEER THESE TESTS SHALL BE PERFORMED PRIOR TO
FINAL ACCEPTANCE OF THE SNE.
13. THE CDAXIAL ANTENNA CABLE INSTALJLS SHALL BE
14. VAPOR WRAP WILL BE USED TO SUL AL
CONNECTIONS.
15. All JUMPERS 70 ME ANTENNAS FROM A MAIN
TRANSMISSION UNE WILL BE 1/2' DA AND SHALL
NOT EXCEED
18. ALL COMAL CABLE WILL BE GROUNDED PRIOR TO
ENTERING THE EOUIPMENT SHELTER AND AS
SPECIFIED IN THE ELECTRICAL DRAWINGS.
17. ALL COAXIAL CABLE WILL BE SECURED TO THE
DESIGNED SUPPORMNG STRUCTURE AT DISTANCES
NOT TO EXCEED A' -D' WITH HARDWARE SPECIFIED
IN THE COAXIAL CABLE ROVING DUMB.
18. ANTENNA CABLE LENGTHS HAVE BEEN DETERMINED
BASED ON THESE PUNS. CABLE LENGTHS LIVED
ARE APPROXIMATED AND ME NOT INTENDED TO BE
USED MR FABRICATION DUE TO FIELD CONDRIONS,
THE CONTRACTOR MUST FIELD VERIFY ALL ANTENNA
CABLE LENGMB PRIOR TO ORDER.
12. ALL MAIN CABLES WILL BE COLOR CODED AT
THREE LOCATIONS AW DETAL B SHEET A.
A AT THE ANTENNA PRIOR }0 JUMPER
B. AT THE MALE BRIDGE EDGE AT BABE OF TOWER
C. AT THE EQUIPMENT PRIOR TO JUMPER
20. RI CONNECTIONS SI BE TORDU[0 TO 1AAUrACI11RE11.9
RECOMMENDATIONS. LOOSE CONNECTIONS AT" BE ME
CONTRACTORS RESPONSIBIUTY TO CORRECT,
A CALIBRATED TORQUE WRENCH SHALL BE USED ON ALL
IF CONNECTIONS.
21, CONTRACTOR IS 10 CONFIRM ANTENNAS SPEC (MODEL
QUANTIFIES. AZIMUTHS AND ANTENNA M211M HFAI HT1 WITH
NEW IT GOV
ANTENNAS OYP. OF 5,
AND (1) VERTEC
0 CORP PROJECT
MANAGER TO PROVIDE
ACTUAL, ORIENTATION
OF ANTENNA.
MOUNT - 85'-0•
PROPOSED TR CORPORATION
88'-3' A)MNRA RAD CENTER
A.
PROPOSED IR CORPORATION
�B3'-5' ANTENNA W. O BOTTOM
OF MOUNT
ANTENRA
�
COAX LAYOUT DETAIL
CARL NOT TO aCNE
ODD
I MR m Nm IPAmx R+NRN[aC4"Rn WR ilil[Rm
w—.-
NII[
00[f
PRMpm
[,RM R FPlrtu
vISTING
X00
W -Y
WA
(I5) 7/8'
FMW[6
FIW1-P WIRY
.1. HJR [ F/['-MIY
COAX CABLES
W -Y
WA
AAIL'AN®
01101-0 KII[Y
Q/[��V{��[��j
VIID
WY•
PROPOSED STT
FRLFiNd
MOA -o WNNM
(5) 1 5/8' AND
IX,v
I■
(u
7/0' COAX CABLES
TRUE NORM
WA M9W •10/Y•hIW
�
COAX LAYOUT DETAIL
CARL NOT TO aCNE
WWW II.I. .0 WW1N1/f FMXWNRMNMILZWWMVIIN
W RME QN. t0 a[ RRNN[0 W T.
ANTENNA SYSTEM MARKING AND LABELING
51MA NOW ro SCALE
TOWER PROFILE
S11A ACT M SGME
FEES STRUCTURAL
04339ulE DATED
06 IV. INSTALL
PROPOSED COM LINES
OI EMPTY TGV[R LEO
{r„ xtv1cpwRce�nc or unec[ [
s I 'ml mv.4haPFem o JGIy Lm[
._ 2PI I saionAl EIBi'Dur under the 1.W'
�_� 9M715
RMNW]NAM[R 6ME: Rry',
433951K3 D 0
YMM 4 s 18 'CME
—1 me I —
I MR m Nm IPAmx R+NRN[aC4"Rn WR ilil[Rm
w—.-
NII[
PRMpm
[,RM R FPlrtu
Aq I N'-I-lu'
TyL
W -Y
WA
NJA
FMW[6
FIW1-P WIRY
.1. HJR [ F/['-MIY
IM[
W -Y
WA
AAIL'AN®
01101-0 KII[Y
IP>[A MINA • I FJ1'-1-HAT
VIID
WY•
WA
FRLFiNd
MOA -o WNNM
[mwe . 11/W.I.IW
IX,v
x'.[•
IMA
N
WA M9W •10/Y•hIW
MMW
Ia[v w [mAI
• 7Ay-I.I V
IyA
W'-!•
WA
WWW II.I. .0 WW1N1/f FMXWNRMNMILZWWMVIIN
W RME QN. t0 a[ RRNN[0 W T.
ANTENNA SYSTEM MARKING AND LABELING
51MA NOW ro SCALE
TOWER PROFILE
S11A ACT M SGME
FEES STRUCTURAL
04339ulE DATED
06 IV. INSTALL
PROPOSED COM LINES
OI EMPTY TGV[R LEO
{r„ xtv1cpwRce�nc or unec[ [
s I 'ml mv.4haPFem o JGIy Lm[
._ 2PI I saionAl EIBi'Dur under the 1.W'
�_� 9M715
RMNW]NAM[R 6ME: Rry',
433951K3 D 0
YMM 4 s 18 'CME
S600
ITT
PERMIT AUTHORIZATION
Advanced Engineering & Sciences
12975 Worldgate DMve
Herndon, VA 20170
I hereby authorize American Tower Corporation to act as agent for ITT Corporation, Advanced
Engineering & Sciences Division in the application for all permits and utility services associated with
this site.
ITT Corporation
Advanced Engineering & Sciences Division
An Indiana Corporation
Y.
Frank Pallante
Title: Vice President of Contracts
Date: 5'-- /7 -JydP
COMMONWEALTH OF VIRGINIA
COUNTY OF FAIRFAX
The foregoing document was acknowledged before me this IP- day of 2009 by
FCosa f; is lta. . who is personally known tome.
WY IWWKYOf 1=Q:L
TM blov TaltalrolM+rtlVSttes OUVU eta
b*m rim !ia
n roma aeuoa
��'rAli1rn11talonmmNes: r< 31,.�r�
My COMI*ft E*M AVW 31, 2M
Of 71%07
SCANNED
U.S. Deportment
of TmrgDWott«,
Fedard Avldbn
Adnlnlshdbn
JAN -2 2008
Mr. Greg Hughes
Contracts Manager, ADS -B Programs
ITT Corporation
Defense Electronics & Services
12975 Worldgate Drive
Hemdon, VA 20170-6008
Re: Automatic Dependent Surveillance -Broadcast (ADS -B)
Contract DTFAWA-07-C-00067
Dear Mr. Hughes:
This letter serves to emphasize to you and your potential partners the importance of the
Federal Aviation Administration (FAA) ADS -B contract which was awarded to ITT
Corporation on August 30, 2007.
The FAA is undertaking a dramatic modernization of the National Airspace System under a
program entitled Next Generation Air Traffic Management Systems (NextGen). The ADS -
B program is the cornerstone of the NextGen. ADS -B will provide technology that in the
near term will enhance safety and in the longer term promise significant system capacity and
efficiency benefits essential to meeting forecasted increases in air traffic demand.
ADS -B is and will remain a high visibility program. Avionics manufacturers and aviation
organizations/companies are relying on the FAA to meet the ADS -B implementation
schedule. The FAA has begun full scale development of the ADS -B system with the award
of the ITT contract and will begin nation wide deployment in the near term.
Any support that can be given to ITT in the development and fielding of ADS -B
infrastructure is strongly encouraged. The FAA considers this program an opportunity to
significantly benefit the nation's transportation infrastructure with new technology.
It is believed that just as in the introduction of the internet, there will be many spin-off
opportunities,
Richaid Day
Vice President !`
En Route and Occanic Sen•i¢es!
i
V
SCANNED
Generous, Bob
From: Tim Jeske [TJeske@TCWR.NET]
Sent: Wednesday, November 18, 2009 8:58 AM
To: Generous, Bob
Subject: RE: Planning Case 09-19
:•.
Thank you for asking, it appears that we will not have interference with our radio communications. If so, we don't have any
additional comments.
Tim
From: Generous, Bob [mailto:bgenerous@ci.chanhassen.mn.us]
Sent: Wednesday, November 18, 2009 8:22 AM
To: Tim Jeske
Subject: FW: Planning Case 09-19
Tim:
Is there anything else you would need.
M
From: Doug Ruwe[mailto:Doug.Ruwe@AmericanTower.com]
Sent: Monday, November 16, 2009 11:19 AM
To: Generous, Bob
Cc: Doug Ruwe
Subject: RE: Planning Case 09-19
=a
As with any equipment mounted on American Tower owned sites, the users are licensed with the FCC for a
specific frequency range. I have requested a copy of the FCC license. It should not interfere with any other
radio equipment. Assuming all radio equipment, ITT's and the railroad's is operating correctly.
Also, I have lost my notes for the meeting dates in December. Could you list the dates and times?
Thanks,
Doug Ruwe
Project Manager- Site Development Services
American Tower Corporation
21307 Rio Oro Dr
Cornelius, NC 28031
704-975-6161 (cell)
From: Generous, Bob[mailto:benerous@ci.chanhassen.mn.us]
Sent: Monday, November 16, 2009 11:59 AM
To: Doug Ruwe
Subject: FW: Planning Case 09-19
Doug:
How do you respond to the railroad's statement/request?
:.1
From: Tim Jeske [mailto:TJeske@TCWR.NEf]
Sent: Monday, November 16, 2009 10:28 AM
To: Generous, Bob
Cc: Bob Suko; Mark Wegner
Subject: Planning Case 09-19
Robert,
I am writing you in response to your notice pertaining to your planning case # 09-19 / PID: 25-8110240 for
additional radio equipment to be added to an existing tower situated close to TCWR property by Lyman
Boulevard.
While we don't object to the structural element of this project we do have concerns pertaining to potential radio
interference. We use radio communications to control train and maintenance traffic on TCWR and interference
with these radio communications will cause operational and safety issues.
If TCWR gets assurance that this project will not interfere with our current radio system or any future
communication needs we would have no objections to this project.
Tim Jeske
Twin Cites & Western Railroad
CITY OF CHANHASSEN
CARVER AND HENNEPIN COUNTIES, MINNESOTA
AMENDED AND RESTATED
CONDITIONAL USE PERMIT #90-3
PLANNING CASE #09-19
1. Permit. Subject to the terms and conditions set forth herein, the City of Chanhassen
hereby grants an amended and restated conditional use permit for the following use which replaces
Conditional Use Permit 90-3:
A Conditional Use Permit for a 115 -foot tall, telecommunication tower
2. Property. The permit is for property situated in the City of Chanhassen, Carver County,
Minnesota, and legally described as Outlot B, Stone Creek First Addition.
3. Conditions. The permit is issued to American Tower Company and Merle and Jane
Volk subject to the following conditions:
a. The tower and antennas shall comply with the requirements in Chapter 20, Article
XXX, Towers and Antennas of the Chanhassen City Code.
b. A building permit is required for equipment pad and LP gas storage tank pad.
c. A mechanical permit is required for connection (gas piping) of LP storage tank to LP
gas generator.
d. The plans must be signed by appropriate design professionals.
e. No signage, advertising or identification of any kind intended to be visible from the
ground or other structures is permitted, except applicable warning and equipment
information signage required by the manufacturer or by Federal, State, or local
authorities.
4. Severability. In the event any provision of this permit shall be held invalid, illegal, or
unenforceable by any court or competent jurisdiction, such holding shall not invalidate or render
unenforceable any other provision hereof, and the remaining provisions shall not in any way be
affected or impaired thereby.
5. Notices. All notices, certificates and other communications hereunder shall be
sufficiently given and shall be deemed given when mailed by certified mail, returned receipt
requested, postage prepaid, with property address as indicated below. The City and the
Association, by written notice given by one to the other, may designate any address or addresses,
to be sent when required as contemplated by this permit. Unless otherwise provided by the
respective parties, all notices, certificates, and communications to each of them shall be
addressed as follows:
To the City: City of Chanhassen
Attn: City Manager
7700 Market Boulevard
P.O. Box 147
Chanhassen, MN 55317
To the Applicant: American Tower
Attn: Doug Ruwe
21307 Rio Oro Drive
Cornelius, NC 28031
To the Owner: Merle and Jane Volk
16925 County Road 40
Carver, MN 55315
6. Reimbursement of Costs. The Applicant shall reimburse the City for all costs,
including reasonable engineering, legal, planning and administrative expenses incurred by the
City in connection with all matters relating to the administration and enforcement of the within
permit and the performance thereby by the applicant. Such reimbursement shall be made within
fourteen (14) days of the date of mailing of the City's notice of costs as provided in Section 5
above. This reimbursement obligation of the applicant under this section shall be a continuing
obligation throughout the term of this permit.
7. Termination of Permit. The City may revoke the permit following a public hearing for
violation of the terms of this permit. The City may institute any proper action or proceeding at
law or at equity to prevent violations of the within property, to restrain or abate violations of the
within permit, or to prevent use or occupancy of the Subject Property.
2
8. Lapse. If within one year of the issuance of this permit the authorized construction has
not been substantially completed or the use commenced, this permit shall lapse, unless an extension
is granted in accordance with the Chanhassen Zoning Ordinance.
9. Assignable. This conditional use permit is issued for the particular use and is not
personal. The City shall be notified in writing at the address provided in section 5 above of any
changes in the leasehold interest or ownership of the underlying property at least thirty (30) days
prior to such change.
10. Criminal Penalty. Violation of the terns of this conditional use permit is a criminal
misdemeanor.
Dated: December 14, 2009
CITY OF CHANHASSEN
M
(SEAL)
STATE OF NM*4NMOTA )
(ss
COUNTY OF CARVER )
Tom Furlong, Mayor
Todd Gerhardt, City Manager
The foregoing instrument was acknowledged before me this_day of , 200_,
by Thomas A. Furlong, Mayor, and by Todd Gerhardt, City Manager, of the City of Chanhassen, a
Minnesota municipal corporation, on behalf of the corporation and pursuant to the authority granted
by its City Council.
DRAFTED BY:
City of Chanhassen
P. O. Box 147
7700 Market Boulevard
Chanhassen, MN 55317
(952)227-1100
3
NOTARY PUBLIC
b
e�
�e
iM M i
_ s wMaw+m.,.ek
Y
ILII iy I
•� '\ rose. .�. VIPJF .:
.y, IMe N
zi
OP
SITE PLAN
LANDSCAPING
•�°X � ..iii i isu.,'oJ . � " n . 3"
R.
I
n i
LANDSCAPING SCHEDULE
w: •� x �
Y
FS�TE PLAN VICINHY MAV
I iV ixs
•� C -to -
OAP
CITY OF CHANHASSEN
CARVER AND HENNEPIN COUNTIES, MINNESOTA
CONDITIONAL USE PERMIT
1. Permit. Subject to the terms and conditions set forth
herein, the City of Chanhassen hereby grants a conditional use
permit for: Commercial communication transmission tower to
support cellular telephone service.
2. Property. The permit is for the following described
property in the City of Chanhassen, Carver County, Minnesota:
See attached Exhibit A.
3. Conditions. The permit is issued subject to the following
conditions:
1. Staff will approve the aesthetic design of the tower and
building and the building should be consistent with other
recently constructed telephone and public utility buildings in
the area.
2. Staff will approve and document the tower shape and structure
and that it's construction will follow that approval.
3. No other radio uses shall be approved without an addendum to
the conditional use permit #90-3 which will come in before the
Planning Commission and City Council.
4. ' Landscaping shall be installed as part of the approved
landscaping plan. A letter of credit guaranteeing
improvements will be required -before building permits are
issued.
5. No lights or signage be placed on the tower or elsewhere on
the site.
6. The tower shall be painted a flat color so that it blends in
with the background.
4. Termination of Permit. The City may revoke the permit
following a public hearing under any of the following
circumstances: material change of condition of the neighborhood
where the use is located and/or violation of the terms of this
permit.
5. Criminal Penalty. Violation of the terms of this
conditional use permit is a criminal misdemeanor.
Date: September 10, 1990
r
Mr. John Uban
September 11, 1990
Page 2
STATE OF MINNESOTA)
) SS
COUNTY OF CARVER )
E
CITY OF
By: .
City Clerk
The foregoing instrument was acknowledged before me this --V'7
�
day of , 19Y0, by Donald J. Chmiel, Mayor and Don
Ashworth, v City Clerk of the City of Chanhassen, a Minnesota
municipal corporation, on behalf of the corporation.
Ri tL.9 / 1 _�/
. ='F ,
Drafted by:
City of Chanhassen
690 Coulter Drive KAREN J. ENG-ELHARDT
NOTARY PUBM _ I. ----,OTA
Chanhassen, MN 55317 CARVER CO;":Ty
(612) 937-1900 ►b w Frftsien me -es 10.19.91
EXHIBIT A
That part of the Northwest Quarter of Section 22, Township 116,
Range 23, West of the 5th Principal Meridian, Carver County,
Minnesota, which lies southwesterly of a line drawn parallel to and
distant 380 feet northeasterly of the centerline of County Road No.
18, as measured at right angles, and which lies southeasterly of a
line drawn parallel to and distant 395 feet northwesterly of the
centerline of the Chicago, Milwaukee, St. Paul and Pacific
Railroad, as measured at right angles. Except that part taken for
County Road No. 18. Except that part taken for the Chicago,
Milwaukee, St. Paul and Pacific Railroad.
OFFICE OF COUNTY RECORDER
STATE OF MINNESOTA
COUNTY OF CARVER
Filing Fee—
This
ee This is to certify that this document
w f in tFFjj++��,�office he _day
0 19X( D.at�o'clock
M. and was duly recorded as
document no. 118396
. HANS NIR -
by. JR.by.
CITY OF CHANHASSEN
AFFIDAVIT OF MAILING NOTICE
STATE OF MINNESOTA)
) ss.
COUNTY OF CARVER )
I, Karen J. Engelhardt, being first duly swom, on oath deposes that she is and was on
November 19, 2009, the duly qualified and acting Deputy Clerk of the City of Chanhassen,
Minnesota; that on said date she caused to be mailed a copy of the attached notice of Public
Hearing for Amendment to CUP 90-3 — Planning Case 09-19 to the persons named on
attached Exhibit "A", by enclosing a copy of said notice in an envelope addressed to such owner,
and depositing the envelopes addressed to all such owners in the United States mail with postage
fully prepaid thereon; that the names and addresses of such owners were those appearing as such
by the records of the County Treasurer, Carver County, Minnesota, and by other appropriate
records.
Subscribed and sworn to before me
this R day of Naiemhe r , 2009.
Notice of Public Hearing
Chanhassen Planning Commission Meeting
Date & Time:
Tuesday, December 1, 2009 at 7:00 P.M. This hearing may not
start until later in the evening, depending on the order of the agenda.
Location:
City Hall Council Chambers 7700 Market Blvd.
Request for an Amendment to Conditional Use Permit 90.3 to
Proposal:
allow co-location/addition of ITT/FAA antennas and radio
equipment at an existing telecommunication tower on property
zoned Agricultural Estate District A2
Applicant:
American Tower Company
Property
2290 Lyman Boulevard (Outlot B, Stone Creek First Addition)
Location:
A location map Is on the reverse side of this notice.
The purpose of this public hearing is to inform you about the
applicant's request and to obtain input from the neighborhood
about this project. During the meeting, the Chair will lead the
What Happens
public hearing through the following steps:
at the Meeting:
1. Staff will give an overview of the proposed project.
2. The applicant will present plans on the project.
3. Comments are received from the public.
4. Public hearing is closed and the Commission discusses
the project.
If you want to see the plans before the meeting, please visit
the City's projects web page at:
www.ci.chanhassen,mn.us/sery/plan/09-19.htmi. If you wish to
talk to someone about this project, please contact Robert
Questions &
Generous by email at baenerous@ci.chanhassen.mn.us or by
Comments:
phone at 952-227.1131. If you choose to submit written
comments, it is helpful to have one copy to the department in
advance of the meeting. Staff will provide copies to the
Commission. The staff report for this Item will be available
online on the project web site listed above the Thursday
prior to the Planning Commission meeting.
City Review Procedure:
• Subdivisions, Planned Unit Developments, Site Plan Reviews, Conditional and Interim Uses, Wetland Alterations,
Rezonings, Comprehensive Plan Amendments and Code Amendments require a public hearing before the
Planning Commission. City ordinances require all property within 500 feet of the subject site to be notified of the
application in writing. Any Interested party Is invited to attend the meeting.
• staff prepares a report on the subject application that includes all pertinent Information and a recommendation.
These reports are available by request. At the Planning Commission meeting, staff will give a verbal overview of
the report and a recommendation. The item will be opened for the public to speak about the proposal as a part of
the hearing process. The Commission will close the public hearing and discuss the item and make a
recommendation to the City Council, The City Council may reverse, affirm or modify wholly or partly the Planning
Commission's recommendation. Rezonings, land use and code amendments take a simple majority vote of the
City Council except rezonings and land use amendments from residential to commemiavindustrial.
• Minnesota State Statute 519.99 requires all applications to be processed within 60 days unless the applicant
waives this standard. Some applications due to their complexity may take several months to complete. Any
person wishing to follow an Item through the process should check with the Planning Department regarding Its
status and scheduling for the City Council meeting.
• A neighborhood spokespersonlrepresentative is encouraged to provide a contact for the city. Often developers
are encouraged to meet with the neighborhood regarding their proposal, Staff is also available to review the
project with any interested person(s).
• Because the Planning Commission holds the public hearing, the City Council does not. Minutes are taken and
any correspondence regarding the application will be included In the report to the City Council. If you wish to have
something to be included In the report, lease contact the Plannino Staff person named on the notification.
Notice of Public Hearing
Chanhassen Planning Commission Meeting
Date & Time:
Tuesday, December 1, 2009 at 7:00 P.M. This hearing may not
start until later in the evening,depending on the order of theagenda.
Location:
City Hall Council Chambers, 7700 Market Blvd.
Request for an Amendment to Conditional Use Permit 90-3 to
Proposal:
allow co-location/addition of ITT/FAA antennas and radio
equipment at an existing telecommunication tower on property
zoned Agricultural Estate District A2
Applicant:
American Tower Company
Property
2290 Lyman Boulevard (Outlot B, Stone Creek First Addition)
Location:
A location map Is on the reverse side of this notice.
The purpose of this public hearing is to inform you about the
applicant's request and to obtain Input from the neighborhood
about this project. During the meeting, the Chair will lead the
What Happens
public hearing through the following steps:
at the Meeting:
1. Staff will give an overview of the proposed project.
2. The applicant will present plans on the project.
3. Comments are received from the public.
4. Public hearing is closed and the Commission discusses
the project.
If you want to see the plans before the meeting, please visit
the City's projects web page at:
www.ci.chanhassen.mn.us/serv/plan/09-19.html. If you wish to
talk to someone about this project, please contact Robert
Questions &
Generous by email at baenerous@ci.chanhassen.mn.us or by
Comments:
phone at 952.227-1131. If you choose to submit written
comments, it is helpful to have one copy to the department in
advance of the meeting. Staff will provide copies to the
Commission. The staff report for this item will be available
online on the project web site listed above the Thursday
prior to the PI Inning Commission meeting.
City Review Procedure;
• Subdivisions, Planned Unit Developments, Site Plan Reviews, Conditional and Interim Uses, Wetland Alterations,
Rezonings, Comprehensive Plan Amendments and Code Amendments require a public hearing before the
Planning Commission. City ordinances require all property within 500 feet of the subject site to be notified of the
application in writing. Any interested party is Invited to attend the meeting.
• Staff prepares a report on the subject application that includes all pertinent Information and a recommendation.
These reports are available by request. At the Planning Commission meeting, staff will give a verbal overview of
the report and a recommendation. The Item will be opened for the public to speak about the proposal as a part of
the hearing process. The Commission will close the public hearing and discuss the item and make a
recommendation to the City Council. The City Council may reverse, affirm or modify wholly or partly the Planning
Commission's recommendation. Rezonings, land use and code amendments take a simple majority vote of the
City Council except rezonings and land use amendments from residential to commercial/industrlal.
• Minnesota State Statute 519.99 requires all applications to be processed within 60 days unless the applicant
waives this standard. Some applications due to their complexity may take several months to complete. Any
person wishing to follow an item through the process should check with the Planning Department regarding its
status and scheduling for the City Council meeting.
• A neighborhood spokesperson/representative is encouraged to provide a contact for the city. Often developers
are encouraged to meet with the neighborhood regarding their proposal. Staff is also available to review the
project with any Interested person(s).
• Because the Planning Commission holds the public hearing, the City Council does not. Minutes are taken and
any correspondence regarding the application will be included in the report to the City Council. If you wish to have
somethingto be included in the report, lease contact the PlanningStaff person named on the notification.
BRADLEY J & RENEE L VANBERGEN BRIAN N JOHNSON BRIAN T & SONYA A BENKSTEIN
2175 BOULDER RD 2207 BOULDER RD 2292 BOULDER RD
CHANHASSEN MN 55317-7402 CHANHASSEN MN 55317-7400 CHANHASSEN MN 55317-7400
CARL D RAY & SEN ZHAO CHAD A & JULIE M EVEN CHAD K & ROCHELLE E CURTIS
2245 STONE CREEK DR 2198 BOULDER RD 2187 BOULDER RD
CHANHASSEN MN 55317-7420 CHANHASSEN MN 55317-7402 CHANHASSEN MN 55317-7402
CHADWICK HOUWMAN CHARLENE A STENDER CHASKA CITY
2219 BOULDER RD 2321 BOULDER RD C/O NOEL GRACZYK
CHANHASSEN MN 55317-7400 CHANHASSEN MN 55317-7401 1 CITY HALL PLAZA
CHASKA MN 55318-1962
CHET A LARSON CHRISTOPHER E FINKE & DANIEL J & NANCY R LYNCH
2259 STONE CREEK DR CHRISTINA G FINKE 2255 BOULDER RD
CHANHASSEN MN 55317-7420 2317 BOULDER RD CHANHASSEN MN 55317-7400
CHANHASSEN MN 55317-7401
DAVID HESTER & DELORIS B HOLASEK TRUST DOUGLAS VERNON JOHNSON
RENEE STEWART-HESTER C/O HOLASEK FARMS LP
2199 BOULDER RD 2015 STAHLKE WAY 2322 BOULDER RD
CHANHASSEN MN 55317-7402 CHASKA MN 55318-3239 CHANHASSEN MN 55317-7401
EDWARD E & ELLEN L RAWSON GARY L FELDICK & GERHARD & HELENE A SCHOCK
2266 BOULDER RD DONNA G NOVAK 2309 BOULDER RD
CHANHASSEN MN 55317-7400 2231 BOULDER RD CHANHASSEN MN 55317-7401
CHANHASSEN MN 55317-7400
GERHARD G & SALLIE L BERGESON IND SCHOOL DIST 112 JAMES M & JENNIFER D
2220 BOULDER RD 11 PEAVEY RD LARRANAGA
CHANHASSEN MN 55317-7400CHASKA MN 55318-2321 2318 BOULDER RD
CHANHASSEN MN 55317-7401
JEFFREY J & KARLA M ALTHOFF
JEFFREY L & GAYLE D SMITH
JEFFREY P & SARAH L WENDORF
2326 BOULDER RD
2279 BOULDER RD
2291 BOULDER RD
CHANHASSEN MN 55317-7401
CHANHASSEN MN 55317-7400
CHANHASSEN MN 55317-7400
MERLE & JANE VOLK
MATTHEW & ROBIN WARDEN
C/O VERIZON WIRELESS
MERLE L & ELIZABETH J OELKE
2308 BOULDER RD
180 WASHINGTON VALLEY RD
2242 BOULDER RD
CHANHASSEN MN 55317-7401
ATTN: NETWORK R
CHANHASSEN MN 55317-7400
BEDMINSTER NJ 07921-2120
MICHAEL & JACQUELINE R MROSKO MICHAEL D & BETTY WRIGHT RAYMOND E &
2305 BOULDER RD 2280 BOULDER RD LORRAINE K RUNYAN
CHANHASSEN MN 55317-7401 CHANHASSEN MN 55317-7400 CHANHASSEN
BOULDER RD
CHANHASSEN MN 55317-7400
RICHARD J & CHERYL A HARTMAN ROLAND A STINSKI
TRUSTEES OF C A HARTMAN TRUST C/O SKYLINE BUILDERS INC
2254 BOULDER RD 3647 MCKINLEY ST NE
CHANHASSEN MN 55317-7400 MINNEAPOLIS MN 55418-1599
SCOTT A HANSON &
CHRISTINE A HANSON
2267 BOULDER RD
CHANHASSEN MN 55317-7400
THOMAS M & CAROLYN D THOMSON
2186 BOULDER RD
CHANHASSEN MN 55317-7402
SCOTT T & NICOLE M BRUSH
2301 BOULDER RD
CHANHASSEN MN 55317-7401
RORY D & AMY J LEA
2313 BOULDER RD
CHANHASSEN MN 55317-7401
STEVEN L & JON] L HANSEN
2208 BOULDER RD
CHANHASSEN MN 55317-7400
ATC SITE NAME:
HAZELTINE
SITE INFORMATION
ITT SITE NUMBER:
ITTSV173-21
a, F� • • �"
ATC SITE NUMBER:
81 388
CITY OF CHANHASSEN
PROJECT TYPE:
COLLOCATE ON EXISTING TELECOMMUNICATIONS TOWER WITH
RECEIVED
2 10 01/09
ADDED GROUND EQUIPMENT CABINET, 10Kw EMERGENCY
OCT 3 0 2009
"^'•"
1.
POWER GENERATOR, AND 120 GALLON PROPANE TANK
(•4
LOCATION:
2290 LYMAN RD
CHANHASSEN PLANNING DEPT
CARVER COUNTY, CHANHASSEN, MN 55317
0 9/22/09
SITE OWNER:
AMERICAN TOWER CORP.
CHLE
OVERVIEW MAP
LOCATION MAP
SITE INFORMATION
LIST OF DRAWINGS
SUBMITTALS
a, F� • • �"
,.
- .,�r«w, ®.<
1. LATITUDE (GPS) 44' 50' 52" N
ARCHITECTURAL
REV. DATE
INITIALS
SH1 COVER SHEET
2 10 01/09
CHILE
g ,r <"-p& a <r••^" ... 11"i # `'=
•
"^'•"
1.
2. LONGITUDE (GPS): 93' 34' 45" W
(•4
'W"•+�
�"�` -'�
•"e., ""'"•" s
SH2 GENERAL NOTES AND ABBREVIATIONS
0 9/22/09
PP
2 10/01/09
CHLE
pm,yf <e•« c'-
i .a
` •s`' �O ..
3. � El TOWER
TYPE OF STRUCTURE.
SH3 COMPOUND PLAN
z}c�R�
o,. °
®LATTICE TOW ER
H4 AND ANTENNA
S TOWER PROFILE
a•p, Un. y `-tea
�"
El MONOPOLE
SPECIFICATION
0 9/23/09
CHILE
•-r
a'ew�-9n oda' e.o- _ — <
L�~° .sd
[ b• e,e
4. GROUND ELEVATION: 945'
SHS ANTENNA INSTALLATION
0 9/22/09
PP
2 10/01/09
CHILE
_ «..+„y,� ' � _
• J'
� � ,iieq
A.M.S.L IN FEET
( )
SH6 ANTENNA MOUNTING DETAILS
r - . _
:1 s .f °
SH7 ANTENNA MOUNTING DETAILS (ISO)
2 10/01/09
CHLE
<n«•am - � ++�< < • I
`"-•.< @ "••<•"'•�g
5. PARCEL ID NO.: 9 4-321 31 32
SH8 PROPANE TANK DETAILS
0 9/22/09
PP
c
"�S-- cA•raw,_:._
J/r
,�""'°°'"
•�-*•
SH9 DETAILS
z 10/01/09
CHILE
ZONING DATA
- ?a .. Ir•
r....r.FL$�HO.d...E��.CT t
s
>v
SH70 EQUIPMENT CABINET DETAILS
0 9/22/09
PP
J11G
1. ZONING CLASSIFICATION: COMMERCIAL
- `
• { "
STRUCTURAL
SH1I STRUCTURAL NOTES AND DETAILS
0 9/22/09
PP
n I• .< _ _
X14
"
"
2. JURISDICTION: CARVER COUNTY
• <,r
C
3. LEASE AREA: 10' X 13' EQUIPMENT PAD WITHIN
F "' "'"'
w•s` �'� `°° "
10' X 15' LEASE AREA
ELECTRICAL
— ! -
3'-6" X 3'-6" CONCRETE PAD FOR
SITE DIRECTIONS
SH72 ELECTRICAL NOTES
0 9/22/09
PP
2 10/01/09
CHLE
' g--uewe
120 GALLON PROPANE TANK.
SH13 ELECTRICAL PLAN
o
TAKE I-494 TO HWY 7, EXIT WEST ON 7 GO ABOUT 9
MILES. GO THROUGH EXCELSIOR. TURN LEFT GO SOUTH
ON HWY 41. CONTINUE SOUTH ON HWY 41 CROSSING HWY
4. HANDICAP REQUIREMENTS: FACILITY WILL BE UNMANNED
SH14 ELECTRICAL RISER DIAGRAM
0 9/22/09
PP
CONTACT INFORMATION
0 9/22/09
PP
5 GO ANOTHER 3/10 MILE TO CARVER CO ROAD
/18. TURN LEFT (EAST) FOLLOW ALONG WINDING ROAD
AND NOT FOR HUMAN
HABITATION. HANDICAP
SH15 RADIO CABINET INTERNAL ELECTRICAL
PANEL
0 9/22/09
PP
ITT CORP JUSTIN STALEY
(LYNN BLVD ABOUT 1 MILE. TOWER IS SELF SUPPORTER
)
ACCESS NOT REQUIRED.
SH17 GROUNDING DETAILS
CONTACT: (571) 203-3236
ON EAST SIDE OF THE ROAD, ABOUT 100 FT DRIVEWAY.
5. (1) PARKING SPACE REQUIRED, USE OF EXISTING
SH77 GROUNDING DETAILS
2 10/01/09
CHILE
POWER COMPANY: %CEL ENERGY
FACILITY.
I
SH18 H -FRAME DETAILS
0 9/22/09
PP
(800) 895-4999
APPLICABLE BUILDING CODES AND STANDARDS
TELCO COMPANY: QWEST
(600) 244-1111
PROPERTY OWNER: MERLE @ JANE VOLK
CONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES AS TELECOMMUNICATIONS INDUSTRY ASSOCIATION/ELECTRONIC INDUSTRIES ASSOCIATION ANSI/TIA-222-G,
16925 COUNTY RD 40
ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION FOR THE LOCATION. THE EDITION OF THE STRUCTURAL STANDARDS FOR STEEL ANTENNA TOWER AND ANTENNA SUPPORTING STRUCTURES.
CARVER, MN 55315
ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OF THE CONTRACT AWARD SHALL GOVERN
THE DESIGN. INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 81, GUIDE FOR MEASURING
TOWER OWNER: AMERICAN TOWER CORP.
EARTH RESISTIVITY, GROUND IMPEDANCE, AND EARTH SURFACE POTENTIALS OF A GROUND SYSTEM.
10 PRESIDENTIAL WAY
BUILDING CODE:
WOBURN, MA 01801
(781)-926-4500
TIA/EIA-222-F, IBC 2006 AND MINNESOTA STATE BUILDING CODE 2007. IEEE 1100 (LATEST EDITION), RECOMMENDED PRACTICE FOR POWERING AND GROUNDING OF ELECTRONIC
TOWER REPRESENTATIVE: JAMES MCINTURF
EQUIPMENT.
(321)-225-4475
ELECTRICAL CODE: IEEE C62.41, RECOMMENDED PRACTICES ON SURGE VOLTAGES IN LOW VOLTAGE AC POWER CIRCUITS (FOR
ARCHITECT: JAMES R. JUSTICE
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 70, NATIONAL ELECTRICAL CODE, 2005 (NEC) LOCATION CATEGORY 'C3" AND 'HIGH SYSTEM EXPOSURE").
900 CIRCLE 75 PARKWAY
SUITE 300
ATLANTA GA 30339
LIGHTNING PROTECTION CODE: NEPA 2000LIGHTNING PROTECTION CODE TIN 607, COMMERCIAL BUILDING GROUNDING AND BONDING REQUIREMENTS FOR TELECOMMUNICATIONS.
-,
770-308-1947
TELOORDIA, GR -1503 COAXIAL CABLE CONNECTIONS.
CONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION TO THE FOLLOWING STANDARDS: FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS REGARDING MATERIAL, METHODS
PE: JAIME REYES
AMERICAN CONCRETE INSTITUTE (ACI) 318, BUILDING CODE REQUIREMENTS FOR REINFORCE CONCRETE OF CONSTRUCTION, OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE REOUIREMENT SHALL GOVERN. WHERE
8505 FREEPORT PARKWAY
AMERICAN INSTITUTE OF STEEL CONSTRUCTION (RISC). MANUAL OF STEEL CONSTRUCTION, ASD, NINTH THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC
SUITE 135
EDITION. REQUIREMENT SHALL GOVERN.
IRVING, TX 75063
972-999-8918
Ids
License q
J
Adwww" &Wbowiq • falmeM
12975 Woddgale Drive
O
Notice:
TM aoant contains company pm pnmy inia^a<nn
It may not t,e reproduoad, or Intomatlon bare in
dwfosed xi0io A w m consent of ITT Gory. AES,
1 D
HAZELTIN E/ITTSV 173-21
2290 LYMAN RD
F-
am 1 a18
DRAWN By PP
ATC JOB NO. 81388
2:
CAGE CODE
9M715
O
(•4
U
zz
0
Q
I)
1
J
Q
„ z
, cpecificat
-•ter`-
u.:der my
1% L.cens
License q
or
Engbwrrd forT
Adwww" &Wbowiq • falmeM
12975 Woddgale Drive
Hemdon, VA. 20170
Notice:
TM aoant contains company pm pnmy inia^a<nn
It may not t,e reproduoad, or Intomatlon bare in
dwfosed xi0io A w m consent of ITT Gory. AES,
1 D
HAZELTIN E/ITTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
am 1 a18
DRAWN By PP
ATC JOB NO. 81388
CAGE CODE
9M715
or
DRAWING NUMBER.
SIZE.
REV:
4339610
1 D
2
SCALE:
am 1 a18
NONE
or
GENERAL NOTES
1. WORK SHALL BE IAW ALL APPLICABLE CODES, ORDINANCES AND REGULATIONS. ALL NECESSARY 16. VERIFY ALL EXMTING DIMENSIONS PRIOR TO PERFORMING WORK.
LICENSES, CERTIFICATES, ETC., REQUIRED BY AUTHORITY HAVING JURISDICTION SHALL BE
PROCURED AND PND FOR BY THE CONTRACTOR. 17. VERIFY THE LOCATION(S) OF ALL BURIED UTILITIES PRIOR TO ANY EXCAVATION.
2. m CORP. HAS NOT CONDUCTED, NOR DOES IT INTEND TO CONDUCT ANY INVESTIGATION AS TO THE
PRESENCE OF HAZARDOUS MATERIAL INCLUDING, BUT NOT LIMITED TO, ASBESTOS WITHIN THE CONFINES
OF THIS PROJECT. IIT CORP DOES NOT ACCEPT RESPONSIBILITY FOR THE INDEMNIFICATION, THE REMOVAL
OR THE EFFECTS FROM THE PRESENCE OF THESE MATERIALS. IF EVIDENCE OF HAZARDOUS MATERIALS IS
FOUND, WORK IS TO BE SUSPENDED AND THE OWNER NOTIFIED. THE CONTRACTOR IS NOT TO PROCEED
WITH WORK UNTIL INSTRUCTED BY THE OWNER IN WRITING.
3. ALL MATERIALS FURNISHED UNDER THIS CONTRACT SHALL BE NEW, UNLESS OTHERWISE NOTED. ALL
WORK SHALL BE GUARANTEED AGAINST DEFECTS IN MATERIAL AND WORKMANSHIP. THE CONTRACTOR
SHALL REPAIR OR REPLACE, ATE HIS/HER EXPENSE, ALL WORK THAT MAY DEVELOP DEFECTS IN
MATERIALS OR WORKMANSHIP WITHIN SAID PERIOD OF TIME OR FOR ONE YEAR AFTER FINAL ACCEPTANCE
OF THE ENTRE PROJECT, WHICHEVER IN GREATER.
4. THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL
EXISTING CONDITIONS AND UTILITIES AT THE JOB SITE BEFORE WORK IS STARTED. NO CLAIMS FOR
EXTRA COMPENSATION FOR THE WORK WHICH COULD HAVE BEEN FORESEEN BY AN INSPECTION,
WHETHER SHOWN ON THE CONTRACT DOCUMENTS OR NOT, WILL BE ACCEPTED OR PAID.
5. THE GENERAL CONTRACTOR AND EACH SUB CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING
DIMENSIONS AND CONDITIONS AT THE JOB SITE WHICH COULD AFFECT THE WORK UNDER THIS
CONTRACT. ALL MANUFACTURERS RECOMMENDED SPECIFICATIONS, EXCEPT THOSE SPECIFICATIONS
HEREIN, WHERE MOST STRINGEN, SHALL BE COMPILED WITH.
6. THE CONTRACTOR SHALL VERIFY AND COORDINATE SIZE AND LOCATIONS OF ALL OPENINGS FOR
STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING, CML, OR ARCHITECTURAL WORK.
7. THE CONTRACTOR SHALL VERIFY THAT NO CONFLICTS EXIST BETWEEN THE LOCATIONS OF ANY AND
ALL MECHANICAL, ELECTRICAL, PLUMBING. OR STRUCTURAL ELEMENTS, AND THAT ALL REQUIRED
CLEARANCES FOR INSTALLATION AND MAINTENANCE ARE MET. NOTIFY THE CONSULTANT OF ANY
CONFUCTS. THE CONSULTANT HAS THE RIGHT TO MAKE MINOR MODIFICATIONS IN THE DESIGN OF
THE CONTRACT WITHOUT THE CONTRACTOR GETTING ADDITIONAL COMPENSATION.
8. DO NOT SCALE THE DRAWINGS. DIMENSIONS ARE EITHER TO THE FACE OF FINISHED ELEMENTS OR
TO THE CENTER UNE OF ELEMENTS, UNLESS NOTE OTHERWISE. CRITICAL DIMENSIONS SHALL BE
VERIFIED WITH THE CONSULTANT.
9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAILY CLEAN UP OF ALL TRADES AND REMOVE ALL
DEBRIS FROM THE CONSTRUCTION SITE. AT THE COMPLETION OF THE PROJECT, THE CONTRACTOR
SHALL THOROUGHLY CLEAN THE BUILDING. SITE, AND ANY OTHER SURROUNDING AREAS TO A
BETTER THAN NEW CONDITION.
10. THE CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL WORK DURING
CONSTRUCTION AGAINST DAMAGE, BREAKAGE, COLLAPSE, ETC. IAW ALL APPLICABLE CODES, STANDARDS,
AND BEST CONSTRUCTION PRACTICES.
11. THE CONTRACTOR SHALL MEET ALL OSHA REQUIREMENTS FOR ALL INSTALLATIONS.
12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES TO THE EXISTING CONSTRUCTION AND
REPAIR ALL DAMAGES TO BETTER THAN NEW CONSTRUCTION. THE CONTRACTOR SHIALL NOTIFY THE
ARCHITECT OF ANY DAMAGE TO THE BUILDING SITE OR ANY ADJACENT STRUCTURES AROUND THE
PROJECT. THE CONSULTANT SHALL BE THE SOLE AND FINAL JUDGE AS TO THE QUALITY OF THE
REPAIRED CONSTRUCTION. ANY ADDITIONAL MODIFICATIONS WHICH MUST BE MADE SHALL BE MADE
AT THE CONTRACTOR'S EXPENSE.
13. WHERE ONE DETAIL IS SHOWN FOR ONE CONDITION, IT SHALL APPLY FOR ALL LIKE OR SIMILAR
CONDITIONS, EVEN THOUGH NOT SPECIFICALLY MARKED ON THE DRAWINGS OR REFERRED TO IN
THE SPECIFICATIONS, UNLESS NOTED OTHERWISE.
14. WHERE NEW PAVING, CONCRETE SIDEWALKS OR PATHS MEET EXISTING CONSTRUCTION, THE
CONTRACTOR SHALL MATCH THE EXISTING PITCH, GRADE, AND ELEVATION SO THE ENTIRE
STRUCTURE SHALL HAVE A SMOOTH TRANSITION.
15. THE CONTRACTOR
AS REQUIRED TO
OR OTHER CONSTRUCTION
BING, ELECTRICAL OR
STRUCTURAL MODIFICATIONS. WHERE THE EXISTING CONSTRUCTION DOORS, PARTITIONS, CEILINGS,
ETC., ARE TO BE REMOVED, MODIFIED, OR REARRANGED OR WHERE THE EXPOSED OR HIDDEN
MECHANICAL, ELECTRICAL SYSTEMS ARE ADDED OR MODIFIED, THE GENERAL CONTRACTOR SMALL
REPAIR, PATCH AND MATCH ALL EXISTING CONSTRUCTION AND FINISHES OF ALL FLOORS, WALLS, AND
CEILINGS. WHERE CONCRETE MASONRY CONSTRUCTION IS MODIFIED, THE CONTRACTOR SHALL TOOTH
IN ALL NEW CONSTRUCTION TO MATCH THE EXISTING BOND. WHERE CONCRETE CONSTRUCTION IS
MODIFIED, THE CONTRACTOR SHALL VERIFY THE EXACT DETAILS TO BE USED FOR CONSTRUCTION.
ALL WORK SHALL BE COVERED UNDER THE GENERAL CONTRACT.
18. IN RAW LAND CONDITIONS, THE TOWER FOUNDATION STRUCTURAL STEEL
IS TO BE GROUNDED PRIOR TO CONCRETE POUR. TOWER FOUNDATION STRUCTURAL
STEEL IS TO BE CONNECTED TO PERMANENT GROUND ROD PRIOR TO TOWER
ERECTION. TOWER GROUND MUST BE MAINTAINED AT ALL TIMES.
19. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR APPLYING FOR
COMMERCIAL POWER IMMEDIATELY UPON REWARD OF CONTRACT. THE GENERAL
CONTRACTOR IS REQUIRED TO KEEP ALL DOCUMENTATION RECEIVED FROM
THE POWER COMPANY. ACKNOWLEDGING APPLICATION FOR POWER, WRITTEN AND
VERBAL DISCUSSIONS WITH THE POWER COMPANY, ETC.
20. THE GENERAL CONTRACTOR SHALL OBTAIN WRITTEN CONFIRMATION OF
THE EXPECTED DATE OF COMPLETION OF THE POWER CONNECTION FROM
THE POWER COMPANY.
21. IF THE POWER COMPANY IS UNABLE TO PROVIDE THE POWER CONNECTION
BY OWNER'S REQUIRED DATE, THE GENERAL CONTRACTOR SHALL PROVIDE
AND MAINTAIN A TEMPORARY GENERATOR UNTIL THE POWER COMPANY
CONNECTION IS COMPLETED. COST ASSOCIATED WITH THE TEMPORARY GENERATOR
TO BE APPROVED BY OWNER.
22. IF THE GENERAL CONTRACTOR FAILS TO TAKE NECESSARY MEASURES AS
DESCRIBED IN NOTES 19, 20 AND 21 ABOVE, THE GENERAL CONTRACTOR SHALL
PROVIDE A TEMPORARY GENERATOR AT NO COST TO THE OWNER.
23. THESE PUNS WERE PREPARED TO BE SUBMITTED TO GOVERNMENTAL BUILDING
AUTHORITIES FOR REVIEW FOR COMPLIANCE WITH APPLICABLE BUILDING CODES
AND IT IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR/SUB CONTRACTOR
TO BUILD ACCORDING TO APPLICABLE BUILDING CODES.
24. IF THE GENERAL CONTRACTOR OR SUB CONTRACTOR FIND IT NECESSARY
TO DEVIATE FROM THE ORIGINAL APPROVED PLANS, THEN IT IS THE GENERAL
CONTRACTOR/SUB CONTRACTOR RESPONSIBILITY TO PROVIDE IT CORP/AMERICAN TOWE
WITH 4 COPIES OF THE NEW CHANGES FOR THERE APPROVAL BY THE OWNER/
GOVERNMENTAL BUILDING AUTHORITIES BEFORE PROCEEDING WITH THE WORK.
THE GENERAL CONTRACTOR/SUB CONTRACTOR SHALL BE RESPONSIBLE FOR
PROCURING ALL NECESSARY INSPECTIONS AND APPROVALS FOR THE
GOVERNMENTAL BUILDING AUTHORITIES DURING AND AFTER THE EXECUTION
OF WORK.
25. THESE PUNS AND SPECIFICATIONS SFWL BE INTERPRETED TO BE A
MINIMUM ACCEPTABLE MEANS OF CONSTRUCTION, AND SHALL NOT RELIEVE
THE GENERAL CONTRACTOR/SUB CONTRACTOR, AND/OR SUPPUER/
MANUFACTURER FROM PROVIDING A COMPLETE AND CORRECT PRODUCT WHEN/
IF ADDITIONAL ITEMS ARE REQUIRED TO MEET THE MINIMUM SPECIFICATION.
IF ANY ITEMS ARE NEEDED TO EXCEED THESE MINIMUM SPECIFICATIONS TO
PROVIDE A COMPLETE, ADEQUATE AND SAFE WORKING CONDITION. THEN IT SFWl
BE DEEMED AND UNDERSTOOD TO BE INCLUDED IN THE DRAWINGS. FOR
EXAMPLE, IF AN ITEM AND/OR PIECE OF EQUIPMENT REWIRES A LARGER
HE
E, (I.E. ELECTRICAL WIRE), STRONGER OR LARGER PIPING. INCREASED
, (LE. STRUCNRAL ELEMENTS), REDUCE SPACING, AND/OR INCREASED
ERSTOOD TO BE INCLUDED IN 7HE BID/PROPOSAL. THESE PLANSNT AS A GUIDE AND ALL ITEMS REASONABLE INFERRED SHALL BE
DEEMED TO BE INCLUDED.
LEGEND
BuILdNG/WALL/DErAIL SECTION LARGE SCALE DETAIL
DETAIL NUMBER
A DETAIL NUMBER
e
SHEET NUMBER A -t
WHERE DETAILED SHEET NUMBER
c
A -t
REFERENCED DRAWING
I ABBREVIATIONS
A/C NR CONDITIONER
ACP
ACOUSTICAL CEILING PANEL
A.F.F.
ABOVE FINISHED FLOOR
ALT.
ALTERNATE
AMS.L
ABOVE MEAN SEA LEVEL
ALUM.
ALUMINUM
AMC.
ANCHOR
L
ANGLE
ARCH.
ARCHrTECTURAL
O
AT
BD.
BOARD
B.F.F.
BELOW FINISHED GRADE
BLDG.
BUILDING
BLK.
BLOCK
BM.
BEAM
DOT.
BOTTOM
BUR
BUILT UP ROOF
CER.
CERAMIC
C.J.
CONTROL JOINT
(i
CENTER LINE
CLC.
CEILING
CLR.
CLEAR
CMU
CONCRETE MASONARY UNIT
CPT.
CARPET
CONC.
CONCRETE
COL.
COLUMN
CONST.
CONSTRUCTION
CONT.
CONTINUOUS
C.T.
CERAMIC TILE
CTR.
CENTER
C/W
COMPLETE WITH
D.F.
DRINKING FOUNTAIN
DA./0
DIAMETER
DN.
DOWN
D.S.
DOWN SPOUT
DTL
DETAIL
EA.
EACH
EIFS
EXTERIOR INSULATION FINISH SYSTEM
EJ.
EXPANSION JOINT
ELEC.
ELECTRIC/ELECTRICAL
EL
ELEVATION
E.P.
ELECTRICAL PANEL
EQ.
EQUAL
E.W.
EACH WAY
EXP.
EXPANSION
EXT.
EXTERIOR
F.D.
FLOOR DRAIN
F.E.C.
FIRE EXTINGUISHER SHELTER
F.H.C.
FIRE HOSE EQUIPMENT
FIN.
FINISH
FIN. FLR. FINISH FLOOR
FLR.
FLOOR
FTG.
FOOTING
CA
GAUGE
GALV.
GALVANIZED
GEN.
GENERAL
GYP.
GYPSUM
GB.
GYPSUM BOARD
H.C.
HANDICAPPED
HK.
HOOK
H.M.
HOLLOW METAL
HOR.
HORIZONTAL
HR.
HOUR
NT.
HEIGHT
AW
IN ACCORDANCE WITH
INSUL
INSULATION
INT.
INTERIOR
Jr.
JOINT
LA
LAYER
LAM.
LAMINATED
LF.
LINEAL FOOT
MANUF.
MANUFACTURER
MATER.
MATERIAL
MAX.
MAXIMUM
MECH.
MECHANICAL
MH
MANHOLE
MM.
MILUMETER
MIN.
MINIMUM
MISC.
MISCELLANEOUS
M.O.
MASONRY OPENING
MPH
MILES PER HOUR
M.S.L.
MEAN SEA LEVEL
MTI_
METAL
N.G.V.D.
NATIONAL GEODITC VERT. DATUM
N.I.C.
NOT IN CONTRACT
NOM.
NOMINAL
N.T.S.
NOT TO SCALE
O.C.
ON CENTER
O.D.
OUTSIDE DIAMETER
OH.
OVERHEAD
OPNG.
OPENING
OPP.
OPPOSITE
OZ.
OUNCE
It
PLATE
PLYWD.
PLYWOOD
PR.
PAIR
P.S.I.
POUNDS PER SQUARE INCH
P.S.F.
POUNDS PER SQUARE FQUT
P.T.
PRESSURE TREATED
RAD.
RADIUS
R.C.
RADIAL CENTER
R.D.
ROOF DRAIN
RECEP.
RECEPTACLE
REINF.
REINFORCED/REINFORCING
REO'D.
REQUIRED
RM.
ROOM
RTU
ROOF TOP UNIT
R/W
RIGHT OF WAY
SCHED.
SCHEDULE
SECT.
SECTION
S.F.
SQUARE FOOT
SIM.
SIMILAR
S.P.
SPLICE POINT
SQ. FT.
SQUARE FEET
S.S.
STAINLESS STEEL
STD.
STANDARD
STL
STEEL
STOR.STORAGE
STRUC.
STRUCTURAL
SUSP.
SUSPENDED
TEMP.
TEMPORARY
THK.
THICK
THICKN.
THICKNESS
T.O.
TOP OF
T.O.S.
TOP OF STEEL
TYP.
TYPICAL
U.N.O.
UNLESS NOTED OTHERWISE
VCT
VINYL COMPOSTION TILE
AF
VERIFY IN FIELD
VERT.
VERTICAL
W/
WITH
WD.
WOOD
WWM
WELDED WIRE MESH
IMPORTANT NOTICE I PROJECT INFORMATION I
THE EXISTING CONDITIONS REPRESENTED HEREIN ARE
BASED ON VISUAL OBSERVATIONS AND INFORMATION
PROVIDED BY OTHERS.
FIT CORP. CANNOT GUARANTEE THE CORRECTNESS
NOR COMPLETENESS OF THE EXISTING CONDITIONS
SHOWN AND ASSUMES NO RESPONSIBILITY THEREOF,
THE CONTRACTOR AND HIS SUB -CONTRACTORS SHALL
VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS
AS REQUIRED FOR PROPER EXECUTION OF THE PROJECT.
REPORT ANY CONFLICTS OR DISCREPANCIES TO THE
CONSULTANT PRIOR TO CONSTRUCTION.
I- THIS IS AN UNMANNED AND RESTRICTED ACCESS EQUIPMENT ROOM AND WILL BE USED FOR THE TRANSMISSION OF RADIO SIGNALS
FOR THE PURPOSE OF AIRPLANE COMMUNICATION.
2. m CORP/AMERICAN TOWER CERTIFIES THAT THIS EQUIPMENT FACILITY WILL BE SERVICED ONLY BY RT CORP. AMERICAN TOWER EMPLOYEES
AND THE WORK ASSOCIATED WITH ANY EQUIPMENT CANNOT BE PERFORMED BY HANDICAPPED PERSONS.
3. NO POTABLE WATER SUPPLY IS TO BE PROVIDED AT THIS LOCATION.
4. NO WASTE WATER WILL BE GENERATED AT THIS LOCATION.
5. NO SOUD WASTE WILL BE GENERATED AT THIS LOCATION.
6. ITT CORP/ AMERICAN TOWER MAINTENANCE CREW, (TYPICALLY ONE PERSON), WILL MAKE AN AVERAGE OF ONE TRIP PER MONTH AT ONE HOUR
PER VISIT.
A4aWla'YAaHeN
Ion. 0T I
direct
the
nl
Name: Raphael 1. Moha
ture:
0/73 License t 44557
ITT
12975 Woddgate Drive
Herndon, VA. 20170
Notice:
TIAsi
ot nlmnvirsmmDaM D"DPpNrynlw n
N m,or,ol0e reDrodce
ua. o torma,ce Upn In
9scbae0 xi1MN w,Xlen [Doom d ITT Cap, AES.
HAZELTI N E/ITTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAWN BY: PP
ATC JOB NO.: 81388
CAGE CODE 9 M 715
I
DRAWRIGNUMBER:
O�/
REV:
433961K3
LL
0
I
SCALE:
s>p* 2 a 18
NONE
Z
O
U
z
O
Q
J
Q
J
EiS- ,
ER
ryrLIL.
z:.:�n.specit
Or under
...
?-N LIC
Ion. 0T I
direct
the
nl
Name: Raphael 1. Moha
ture:
0/73 License t 44557
ITT
12975 Woddgate Drive
Herndon, VA. 20170
Notice:
TIAsi
ot nlmnvirsmmDaM D"DPpNrynlw n
N m,or,ol0e reDrodce
ua. o torma,ce Upn In
9scbae0 xi1MN w,Xlen [Doom d ITT Cap, AES.
HAZELTI N E/ITTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAWN BY: PP
ATC JOB NO.: 81388
CAGE CODE 9 M 715
DRAWRIGNUMBER:
SIZE
REV:
433961K3
D
0
I
SCALE:
s>p* 2 a 18
NONE
COMPOUND NOTES
1. THE MINIMUM LOWEST FIRST FLOOR ELEVATION SHALL NOT
BE LESS THAN 4• ABOVE CROWN OF ROAD, OR THE FEDERAL
AND/OR COUNTY FLOOD CRITERIA ELEVATION, WHICHEVER IS
HIGHER. THE GENERAL CONTRACTOR/SUB CONTRACTOR SHALL
SUBMITT AN ELEVATION CERTIFICATE UPON THE COMPLETION
OF WORK.
2. WORK OUTSIDE OF THE PROPERTY LINE INCLUDED IN THIS
SET OF DRAWINGS SHALL BE, BUT NOT LIMITED TO, DRIVEWAYS,
SODDING TO ASPHALT LINE AND UTILITY CONNECTIONS.
3. THE GENERAL CONTRACTOR AND SUB CONTRACTOR SHALL
VERIFY ALL UTILITY SERVICE CONNECTION LOCATIONS PRIOR
TO SUBMITTING A BID AND PROCEEDING WITH ANY WORK. IT
IS RECOMMENDED THAT THE GENERAL CONTRACTOR VISIT THE
SITE AND VERIFY ALL DIMENSIONS AND NOTES BEFORE
SUBMITTING A BID AND BEFORE PROCEEDING WITH ANY WORK.
4. SOIL AT THIS SITE IS ASSUMED TO BE ADEQUATE OF
SUPPORTING THE DESIGN LOAD OF 2000 P.S.F. IF OTHER
CONDITIONS ARE ENCOUNTERED, NOTIFY ITT CORP. AND THE
OWNER BEFORE PROCEEDING WITH WORK. THIS VALUE IS
CONSIDERED SAFE WITH RESPECT TO ACTUAL FAILURE OF
THE SUPPORTING GROUND, BUT DOES NOT NECESSARILY
ENSURE THE PREVENTION OF EXCESSIVE FOUNDATION
MOVEMENTS.
5. BURY PHONE, AND ELECTRICAL SERVICE NO LESS THAN
18• BELOW THE FINISHED GRADE, WITH A 1'-O• RADIUS
SAND BACKFILL AROUND PIPES. COORDINATE WITH
ELECTRICAL DRAWINGS.
6. IN ORDER TO AVOID ANY CONFLICTS, THE GENERAL
CONTRACTOR SHALL COORDINATE ALL OF HIS SUB
CONTRACTORS AND PRACTICAL TRADES.
7. ALL SOILS TO BE REMOVED FROM SITE AND PROPERLY
DISPOSED OF OFF PROPERTY. IF HAZARDOUS MATERIALS
ARE ENCOUNTERED, REMOVAL AND DISPOSAL SHOULD BE
COMPLETED ALONG WITH DISPOSAL DOCUMENTATION.
8. BURNING OF DEBRIS IS NOT ALLOWED.
9. SILT FENCING SHALL BE EMPLOYED IF DEEMED NECESSARY.
GENERA NOTES:
• HEIGHT: EXCLUDING THE TOWER, NO EXISTING OR PROPOSED
STRUCTURE (INCLUDING EQUIPMENT) WILL EXCEED THE HEIGHT
LIMITATIONS OF THE DISTRICT.
*LIGHTING: THE PROPOSED INSTALLATION AND EXISTING FACILITY WILL
MEET OR EXCEED ALL FAA AND FCC REGULATORY REQUIREMENTS.
• GRADE: EXISTING GRADE WILL BE MAINTAINED FOR PROPOSED
CONSTRUCTION.
• PARKING: ONE PARKING SPACE IS REQUIRED, ONE EXISTING.
• SIGNAGE: EXTERIOR SIGNS ARE NOT PROPOSED EXCEPT AS
REQUIRED BY THE FCC.
• STORM WATER CONTROL THE PROPOSED FACILITY WILL RESULT IN
AN INSIGNIFICANT INCREASE IN STORM WATER RUNOFF.
CONSEQUENTLY, NO WATER QUALITY CONTROL DEVICES ARE
PROPOSED.
• UTILITIES: SANITARY SEWER SERVICE AND POTABLE WATER ARE NOT
APPLICABLE PER THE USE. IF APPLICABLE, SUBCONTRACTOR SHALL
LOCATE ALL UTILITIES PRIOR TO EXCAVATING.
• DRNEWAY: A DRIVEWAY PERMIT IS NOT REQUIRED FOR THIS
PROJECT. THE PROJECT WILL NOT REQUIRE RIGHT-OF-WAY OR
PROPERTY TO BE DEDICATED FOR PUBLIC USE.
•MISC: NO NOISE, SMOKE, DUST, VAPORS OR ODOR WILL RESULT
FROM THIS PROJECT.
COMPOUND VIEW
20' X 100' PAVED ACCESS DRIVE
EXISTING CHANUNK
FENCE W/3 -STRAND
BARBED WIRE
(1) PARKING /
SPACE PROPOSED ITT
POWER ROUTING
c ^d PROPOSED ITT
TELCO ROUTING
Ci� Y v
1O
_
TL.
` GRAVEL \
SURFACES \ 10.
r\ \ 10' SPARK
BUFFER
ry
PROPOSED.Y3' \d PROPOSED TT / \ 10' X 13' / 120 OCL
EQUIPMENT PAD PROPANE TANK
\ WITHIN 10' X 15'
LEASE AREA /.
\ PROPOSED ITT LATTICE Y n
H–FRAME TONER
PROPOSED ITT
0p\Qc;� 4 3._8. X 3._6.
CONCRETE PAD
EXISTING ��' 1- / FOR 120 GALLON
LESSEE/USR EER tQ / PROPANE TANK
4 J
SHELTER X
SP
x
PROPOSEDfR GPS (2) A
ATTACHED TO THE ICE Y b
BRIDGE IN TWO PLACES \ 'S� .Yh PROPOSED ITT
8' MINIMUM SEPARATION o. \ / tiQ / "� GAS LINE ROUTING
\\\\ PROPOSED ITT
4Q ICE BRIDGE
PROPOSED ITT
LP GAS GENERATOR
— PROPOSED ITT NEMA
3R 18• X 12• X 6• BOX
PROPOSED ITT
CABINET
N
COMPOUND PLAN
NOTE:
SH3 SCALE: 1•=5' (BASED ON 24X36 •D• PAPER SIZE) SEE PROPOSED ICE BRIDGE, SHEET 9
TRUE NORTH SCALE: 1•=10' (BASED ON 11X17 •B• PAPER SIZE)
J
ON
-RAWNGNUMBERSIZE:
I..L
REV.
433961K3
D
Z
vm 3 s 18
O
(3
U
z
O
Q
LLJ J
Q
S II
LP
direct I
11 A the
Name: __
lohan ed
l0bld") License M 44557
Engineered for life
AdV*nmd Ill"hwMN Al Sull w
12975 Woddgate Drive
Herndon, VA. 20170
Nofice:
Tn. doament mntoni can ypl on lny i�lotnuEon
I'. may not be reproduced, or tnimmaBoa hone F
tlisdosed wNwut written wnunt of ITT Corp, AES.
HAZELTI NEIITTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAWN BY: PP
ATC JOB NO.: 81388
AGECODE I 9M715
-RAWNGNUMBERSIZE:
REV.
433961K3
D
2
vm 3 s 18
SCALE:
NONE
LINE/ANTENNA NOTES
1. SEE DRAWING SHEET 3 FOR COMPOUND PLAN.
2. ALL THREADED STRUCTURAL FASTENERS FOR ANTENNA
SUPPORT ASSEMBLIES SHALL CONFORM TO ASTM A307
OR ASTM A36. ALL STRUCTURAL FASTENERS FOR
STRUCTURAL STEEL FRAMING SHALL CONFORM TO ASTM
A325. FASTENERS SHALL BE 5/8" MIN. DIA. BEARING
TYPE CONNECTIONS WITH THREADS EXCLUDED FOR THE
PLANE. ALL EXPOSED FASTENERS, NUTS, AND WASHERS
SHALL BE GALVANIZED UNLESS OTHERWISE NOTED.
CONCRETE EXPANSION ANCHORS SHALL BE HILTI KWIK
BOLTS UNLESS OTHERWISE NOTED. ALL ANCHORS INTO
CONCRETE SHALL BE STAINLESS STEEL
3. THE GENERAL CONTRACTOR/SUB CONTRACTOR SHALL
FURNISH ALL CONNECTION HARDWARE REQUIRED TO
SECURE THE CABLES. CONNECTION HARDWARE SHALL
BE STAINLESS STEEL.
4. NORTH ARROW SHOWN ON THE PLANS REFERS TO
TRUE NORTH. THE GENERAL CONTRACTOR/SUB CONTRACTOR
SHALL VERIFY NORTH AND NOTIFY ITT CORP/TBD OF
ANY DISCREPANCY BEFORE STARTING CONSTRUCTION.
5. PROVIDE LOCK WASHERS FOR ALL MECHANICAL
CONNECTIONS FOR GROUNDING CONDUCTORS. USE
STAINLESS STEEL HARDWARE THROUGHOUT.
6. THOROUGHLY REMOVE ALL PAINT AND CLEAN ALL
DIRT FROM SURFACES REQUIRING GROUND CONNECTIONS.
7. MAKE ALL GROUND CONNECTIONS AS SHORT AND
DIRECT AS POSSIBLE. AVOID SHARP BENDS. ALL BENDS
TO BE A MIN. OF B" RADIUS.
B. FOR GROUNDING TO BUILDING FRAME AND HATCH
PLATE GROUND BARS. USE A TWO -BOLT HOLE NEMA
DRILLED CONNECTOR SUCH AS A T&B 32007 OR
AN APPROVED EQUAL PART.
9. FOR ALL EXTERNAL GROUND CONNECTIONS, CLAMPS
AND CADWELDS, APPLY A LIBERAL PROTECTIVE COATING
OR AN ANTI -OXIDE COMPOUND SUCH AS "NO -OXIDE A"
BY DEARBORN CHEMICAL COMPANY.
10. REPAIR ALL GALVANIZED SURFACES THAT HAVE BEEN
DAMAGED BY THERMOWELDING WITH COLD GALV. PAINT.
It. SEAL ALL CONDUITS PENETRATIONS INTO STRUCTURES
AND ALL CONDUIT OPENINGS WITH A SILICONE SEALANT.
12. THE COAXIAL ANTENNA CABLE INSTALLER SHALL BE
RESPONSIBLE FOR PERFORMING AND SUPPLYING SWEEP
TESTS (ANTENNA RETURN LOSS TEST). THIS TEST SHALL BE
PERFORMED TO THE SPECIFICATIONS AND PARAMETERS
OUTLINED BY THE ITT CORP. RADIO FREQUENCY THRU
ENGINEER. THESE TESTS SHALL BE PERFORMED PRIOR TO
FINAL ACCEPTANCE OF THE SITE.
13. THE COAXIAL ANTENNA CABLE INSTALLER SHALL BE
RESPONSIBLE FOR PERFORMING AND SUPPLYING ITT CORP.
WITH TIME DOMAIN REFLECTOMETER TESTS TO VERIFY CABLE
LENGTH AND TO CHECK FOR WATER DAMAGE.
14. VAPOR WRAP WILL BE USED TO SEAL ALL
CONNECTIONS.
15. ALL JUMPERS TO THE ANTENNAS FROM A MAIN
TRANSMISSION LINE WILL BE 1/2" DIA. AND SHALL
NOT EXCEED 6'-0".
16. ALL COAXIAL CABLE WILL BE GROUNDED PRIOR TO
ENTERING THE EQUIPMENT SHELTER AND AS
SPECIFIED IN THE ELECTRICAL DRAWINGS.
17. ALL COAXIAL CABLE WILL BE SECURED TO THE
DESIGNED SUPPORTING STRUCTURE AT DISTANCES
NOT TO EXCEED 4'-0" WITH HARDWARE SPECIFIED
IN THE COAXIAL CABLE ROUTING DETAILS.
18. ANTENNA CABLE LENGTHS HAVE BEEN DETERMINED
BASED ON THESE PLANS. CABLE LENGTHS LISTED
ARE APPROXIMATED AND ARE NOT INTENDED TO BE
USED FOR FABRICATION DUE TO FIELD CONDITIONS.
THE CONTRACTOR MUST FIELD VERIFY ALL ANTENNA
CABLE LENGTHS PRIOR TO ORDER.
19. ALL MAIN CABLES WILL BE COLOR CODED AT
THREE LOCATIONS IAW DETAIL B, SHEET 4.
A. AT THE ANTENNA PRIOR TO JUMPER
B. AT THE CABLE BRIDGE EDGE AT BASE OF TOWER
C. AT THE EQUIPMENT PRIOR TO JUMPER
20. RF CONNECTIONS SHALL BE TORQUED TO MANUFACTURER'S
RECOMMENDATIONS. LOOSE CONNECTIONS WILL BE THE
CONTRACTORS RESPONSIBILITY TO CORRECT.
A CALIBRATED TORQUE WRENCH SHALL BE USED ON ALL
RF CONNECTIONS.
21. CONTRACTOR IS TO CONFIRM ANTENNAS SPEC (MODEL,
QUANTIFIES, AZIMUTHS AND ANTENNA MOUNT HEIGHT) WITH
ITT CORP/CONSTRUCTION MANAGER PRIOR TO INSTALLATION
FINAL ANTENNA 6 MOUNT ADJUSTMENTS SHALL BE
COMPLETED USING A MODEL # SPAA05-NEX.
INFORMATION CAN BE FOUND ON THE WEB AT
WWV.SPAA05.CDM/INDEX.PHP FINAL DATA SHALL BE
INCLUDED IN THE CLOSE-OUT PACKAGE.
NEW ITT CORP
ANTENNAS (TYP. OF 5)
AND (1) VERTEX
ANTENNA.
ffT CORP PROJECT
MANAGER TO PROVIDE
ACTUAL ORIENTATION
OF ANTENNA.
ATC STRUCTURAL
AND CENTER OF
MOUNT = 95'-0"
PROPOSED ITT CORPORATION
99'-3" ANTENNA RAD CENTER
PROPOSED ITT CORPORATION
�93'-6" ANTENNA HT. O BOTTOM
OF MOUNT
\ A.G.L.
ANTENNA
EXISTING---
XISTING 7/8'
VER
(15) 7/8'
COAX CABLES
PROPOSED ITT \U0�
(5> 1 5/8' AND
(1) 7/8' COAX CABLES
TRUE NORTH
COAX LAYOUT DETAIL
NOT TO SCALE
mffEMNA
WIB(
4iIDR
TYPE SIATL15 AmrEmNA COAm CANE AZMUTM COAIIML COAA'NL CABLE AN1fORN
O rTID LD04Tcoi (a-MDRM COLOR CODE SME—NW—LENGTH COISTAXMTION
RADMTIOM
CENTER
TW
A-1
A
PROPOSED 5100 1)
BOTTOM D—W
RED • 1 5/8--1-123'
TX/RX
99'-3'
N/A
A-2
A
PROPOSED 51004-()
WT 9D -18O
BLUE • 1 5/8--1-123'
TX/RX
99'-3'
N/A
A-3
A
PROPOSED 51004-D
BOT*OM 18D-270
GREEN ' 1 5/8--1-123'
1R/rX
99'-3'
N/A
A-4
A
PROPOSED 51004-D
BOTTOM 270-360
BROWN ' 1 5/8'-1-123'
TX/RX
99'-3'
N/A
B-2
B
PROPOSED 5100-A
BOTS N/A
YELLOW • 1 5/8'-1-123'
TX/ID(
99'-3-
N/A
C-2^
C
YERfEX PROPOSED 101v VPD
NTITOM MAWS
WHITEYELLOW • 7/8'-1-123'
1%/qX
9J'-3'
N/A
• (5) 1 5/8' COAX LINES AND (1) 7/8- COM( ME TO BE THE MNL CONFIGUPAnON.
^ SNE DEPENDENT.
RF INFORMATION TO BE PROVIDED BY m. -
ANTENNA SYSTEM MARKING AND LABELING
NOT TO SCALE
115'-0" TOP OF STEEL
EXISTING VERIZON
114-0 A.
PROPOSED ITT CORPORATION
ANTENNA RAD CENTER
PROPOSED ITT CORPORATION
ANTENNA HT. ® BOTTOM OF
NOTE,
PER STRUCTURAL
#43396122 DATED
06/03/09 INSTALL
PROPOSED COAX LINES
ON EMPTY TOWER LEG.
OF STEEL
A TOWER PROFILE
SH4 NOT TO SCALE
Lo w
O.
C9 I -
Z W
1= U
V) �}
W
NOTE: NO WORK SHALL COMMENCE WITHOUT THE APPROVED STRUCTURAL TOWER ANALYSIS
REPORT, (SIGNED AND SEALED), PROVIDED BY OTHERS UNDER SEPARATE COVER. THE
CONTRACTOR, PRIOR TO CONSTRUCTION, SHALL RENEW THE APPROVED TOWER STRUCTURAL
ANALYSIS SUPPLIED BY IIT CORP/AMERICAN TOWER AND MODIFY IF REQUIRED ALL APPLICABLE
MEMBERS AS INDICATED IN CERTIFIED STRUCTURAL REPORT PRIOR TO INSTALLATION OF
ANTENNAS AND COAX. NOTE: THE CONTRACTOR SHALL PROVIDE PROPER RING MOUNT. ALL
MOUNTING PIPES, ALL ATTACHMENT PLATES AND BOLTS REQUIRED FOR PROPER AND COMPLETE
INSTALLATION. SUBMIT ALL SHOP DRAWINGS FOR APPROVAL COORDINATE ANTENNA ATTACHMENT
WITH TOWER ANALYSIS REPORT.
J
0N
1..6-
Z
0
0 z
License
En life
T
AbAneM MVkwMfry t te1�
12975 Woddgate Drive
Herndon, VA. 20170
Notice:
T. mw tcameos �Y PmwK' Mrw wl
n m.y mt be reprotluce0. or infoemation Here in
aiee dcaiman w,men mneem er" cam. AEs.
HAZELT I N E/ITTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAWN By PP -7
ATC X)8 NO.: 81388
CAGE CODE 9M715
0
DRAWING NUMBER:
SRE
REV.
Q
D
J
�
WI Q
WR! 4 a 18
NONE
>1 ,.
L ..831
License
En life
T
AbAneM MVkwMfry t te1�
12975 Woddgate Drive
Herndon, VA. 20170
Notice:
T. mw tcameos �Y PmwK' Mrw wl
n m.y mt be reprotluce0. or infoemation Here in
aiee dcaiman w,men mneem er" cam. AEs.
HAZELT I N E/ITTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAWN By PP -7
ATC X)8 NO.: 81388
CAGE CODE 9M715
daect
ti:c
DRAWING NUMBER:
SRE
REV.
433961 K3
D
I 0
SCAJF
WR! 4 a 18
NONE
daect
ti:c
TO BE PROVIDED BY ITT
c
A ANTENNA INSTALLATION
SHS SCALE: NOT TO SCALE
.�
aan
License
Enfflnwmd T
12975 Woddgate Drive
Hemdon, VA. 20170
Notice:
IIt may nol D reproduced, or infann.t. here in
disclosed wil ui wrMen concent of ITT Cory, AES
HAZELTINE/ITTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAWN BY PP o Q p
ATC JOB NO: 8 1 380
CAGECODE 9M715
DRAWING NUMBER: sa REV:
433961K3 ID 0
SCALE:sur 5 t< 18 NONE
J
O
ry
f -
z
O
U
z
O
Q
ry
J
J
Q
speciiicau
n, or
c
laws of
License
Enfflnwmd T
12975 Woddgate Drive
Hemdon, VA. 20170
Notice:
IIt may nol D reproduced, or infann.t. here in
disclosed wil ui wrMen concent of ITT Cory, AES
HAZELTINE/ITTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAWN BY PP o Q p
ATC JOB NO: 8 1 380
CAGECODE 9M715
DRAWING NUMBER: sa REV:
433961K3 ID 0
SCALE:sur 5 t< 18 NONE
V
ARM ASSEMBLY
HDSA12, OR EQ.
ANTENNA, DB SYSTEMS
51DOA-D ADS -B, QTY. 2,
(1090)
PIPE ADAPTER
DB SYSTEMS P/N
510500-100
CONNECT -IT DAP -2-4P
ANTENNA PLATE OR EQ., TYP. (2)
`VALMONT 83130 UNIVERSAL
/ PIPE TO PIPE ADAPTER KR
/ OR EQ. TYP.
CLAMP
LIGHTNING ROD ASSY,
DB SYSTEMS
P/N 510625-100
OR EQ., TYP.
18� I
(RAD CENTER)
106^
77"
4' DIA PIPE
(3-1/2' NPS
SCD 40)
36^
V14"C
0' .
2�^
CONNECT -IT 6' STANDOFF
MOUNT, HS6
I" DIA MOUNTING PIPE
(3-1/2' NPS SCD 40) (23/PI
85 SCD 40)
INSTALL ONLY IF REQUIRED, SEE PROPOSED ANTENNA AND COAXIAL
SCHEDULE. REMOVE DRAIN PLUGS.
e•
J
T
(RAD CENTER)
GENERAL DYNAMICS
MODEL 101V VPD ANTENNA
VERTEX RSI
(1030) OR ANTENNA ASSOC
M205 (1030)
510OA— D ADS—B ANTENNA (1090)
WITH OPTIONAL 101V VPD ANTENNA (1030
A ANTENNA MOUNT DETAILS
SH6 NOT TO SCALE
sNOTES'
'—o'
A. LIGHTNING RODS ONLY INSTALLED WHEN ITT IS
AT THE TOP OF THE TOWER OR ONLY TENANT ON
TOWER (TO BE SUPPLIED BY ITT)
B. TORQUE ALL 1/2' HARDWARE TO 50-60 FT -LBS.
C. TORQUE ALL 5/8' HARDWARE TO 100-120
FT -LBS.
CONNECT -R STIFF
ARM ASSEMBLY
HDSA12, OR EQ.
LIGHTNING ROD ASSY,
DB SYSTEMS
P/N 510625-100
OR EQ., TYP.
ANTENNA, DB SYSTEMS
5100A ADS -B, QTY. 1,
(UAT)
VALMONT E13130 UNIVERSAL
PIPE TO PIPE ADAPTER KR
OR EQ. TYP.
CLAMP SWIVEL CONNECTION
4^ DIA MOUNTING PIPE
(3-1/2' NPS SCD 40)
ANTENNA CONNECTORS
THE TORQUE TO ATTACH THE CONNECTOR TO THE
ANTENNA IS 15-20 INCH -LBS. DO NOT
OVER -TORQUE THE ANTENNA CONNECTOR. THE
CORRECT MANUFACTURER -SUPPLIED TORQUE
WRENCH IS ANDREW P/N 244379. NOTICE THE
UNIT OF MEASUREMENT - ANTENNA CONNECTOR
TO BE INSTALLED WITH INCH -LHS ONLY.
18�^
(RAD CENTER)
107^
TWO (2) ANDREW
77" BC -35-14 TESSCO
#448849
PIPE ADAPTER
DB SYSTEMS P/N
510500-100 68^
-R 6'
j5 2 36^
MAsr PIPE
— GROUND
4^ DIA PIPE
(3-1/2^ NPS SCD 40)
CONNECT -TT GP20-40
(DO NOT FIELD CUT)
5100A ADS—B ANTENNA (UAT)
.Y>Rlsv.nea
R ep
i1
'v;''a�.l I.
W Englaamed T
A dvanwd 0 11 M t IeU1i
12975 Woddgate Drive
Herndon, VA. 20170
Notice:
This deo,mem ta
wnies wmoany emodetanmr
inm to�
I: may not oe reproduced, or information herein
diu dvMnout wrftm wr.nt o11TT Cory. AES,
HAZELTI NE/ITTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAWN BY: PP
ATC JOB NO, 81388
--=I 9M715
J
0�/
D
2
va' x
Of
F_
Z
O
U
z
O
Q
Q
W
J
U
ES~_
_
jhrt
v er'
specil
was ,i,.
. oder
i1
'v;''a�.l I.
W Englaamed T
A dvanwd 0 11 M t IeU1i
12975 Woddgate Drive
Herndon, VA. 20170
Notice:
This deo,mem ta
wnies wmoany emodetanmr
inm to�
I: may not oe reproduced, or information herein
diu dvMnout wrftm wr.nt o11TT Cory. AES,
HAZELTI NE/ITTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAWN BY: PP
ATC JOB NO, 81388
--=I 9M715
OC I
433961 K3
D
2
va' x
NONE
OC I
*'1'O
�Oq
k
SOpp
ORTfd
TO
TOa O
R
S/dF STAND OFF BR,
OT 6 1/2 SNAP IN
NOTES,
A. LIGHTNING RODS ONLY INSTALLED
WHEN ITT IS AT THE TOP OF THE
TOWER OR ONLY TENANT ON
TOWER (TO BE SUPPLIED BY ITT)
B. TORQUE ALL 1/2' HARDWARE TO
50-60 FT -LBS.
C. TORQUE ALL 5/8' HARDWARE TO
I
ANTENNA CONNECTORS
THE TORQUE TO ATTACH THE CONNECTOR TO THE
ANTENNA IS 15-20 INCH -LBS. DO NOT
OVER -TORQUE THE ANTENNA CONNECTOR. THE
CORRECT MANUFACTURER -SUPPLIED TORQUE
WRENCH IS ANDREW P/N 244379. NOTICE THE
UNIT OF MEASUREMENT - ANTENNA CONNECTOR
TO BE INSTALLED WITH INCH -LBS ONLY,
ALL GROUNDING AT RAD CENTER TO TERMINATE AT RAD CENTER
BUSS BAR—USE #2 STRANDED LUGGED INTO THE BUSS BAR PER
DETAIL C IN SHEET 17.
J
/-Ol/
LL_
F—
];;7
O CD
U z
ire_
Lt....i15e
,� TT
Advrro...n.N....rn. A $0
12975 Worldgate Drive
Herndon, VA. 20170
Notice:
This aoammt innlams mmoany o,o Wr, nlotmalion
It may not oo reproducam, or information bane In
d,s d "Irn t written mnaent of ITT Cory, AES.
HAZELTI N E/ITTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
UuV'NBY PP
.TUDB NO, 81388
cAGECODE 1 9M715
(AS REQUIRED PER RF)DRAWING NUMBER. SIZE: IREv:
A ANTENNA MOUNT DETAILS 433961 K3 D 2
10 SH7 NOT TO SCALE SCALE:s¢r 7 a 18 NONE
or I
O
Q
J
C)
I
_
U)_
ire_
Lt....i15e
,� TT
Advrro...n.N....rn. A $0
12975 Worldgate Drive
Herndon, VA. 20170
Notice:
This aoammt innlams mmoany o,o Wr, nlotmalion
It may not oo reproducam, or information bane In
d,s d "Irn t written mnaent of ITT Cory, AES.
HAZELTI N E/ITTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
UuV'NBY PP
.TUDB NO, 81388
cAGECODE 1 9M715
(AS REQUIRED PER RF)DRAWING NUMBER. SIZE: IREv:
A ANTENNA MOUNT DETAILS 433961 K3 D 2
10 SH7 NOT TO SCALE SCALE:s¢r 7 a 18 NONE
or I
—�V TRENCH CAUTIONARY TAPE
FINISHED GRADE, OR GROUND
COVER MATCH SLOPE AND
THICKNESS OF EXISTINGW//
COMPACTED BACKFILL
SATISFACTORY NATIVE
UNDISTURBED SOIL
�Ok IMPORTED SOIL
a
v
SAND
1)
3/4' HIGH PRESSURE
LYPIPE' FOR PROPANE
DIRECT BURIED CONDUIT
SH8 NOT TO SCALE
10' THK. CONC. SLAB —
5000 PSI W/ APPROVED
WIRE MESH REINFORCEMENT
(BOTH DIRECTIONS)
a
CHAMFER
4' 157 CRUSHED STONE
MA RIAL ON LANDSCAPE
WEED BARRIER ON WELL
COMP. FILL
-GNI E
(2) /5 REBAR AROUND PAD
120 GAL. PROPANE TANK PAD SECTION
NOT TO SCALE
2ND STAGE_
REGULATOR/GUAGE
LONGEST RUN = 318'-0'
Cur
TO GEN
GROUND TO GENERATOR
LOCATION
NOTE: CONTRACTOR VERIFY
EXACT LOCATION OF GAS
ROUTING IN FIELD. FBC
GAS TABLE 402.4 (24) / �
1//210 ((MIN.) HIGH PRESSURE
'POLYPIPE' 24' MIN. UNDERGROUND
TO GENERATOR LOCATION.
NOTE: CONTRACTOR TO FIELD VERIFY
TOP OF SLABEXACT LOCATION OF GAS ROUTING.
LONGEST RUN 395'-0'
FBC GAS TABLE 402.4 (31)
POLYPIPE TO GENERATOR PENETRATION
PIPING ISOMETRIC TERMINATION CANNOT EXCEDE 70'
C
SH8 NOT TO SCALE
2 AWG
CONDUCT R TO C
RING (TYP.) IN C
CONDUIT AND SILICONE
WITH EXPANSION BOLT
! PART / 59124, BOLT "
31 SB, PART j 59135 P?.•.
tEBAR AROUND PERIMETER
SUB
120 GAL. PROPANE TANK PAD ELEVATION
NOT TO SCALE
20 GAL CYLINDER TANK
1-1/2' z 18 GAUGE
ATL. STRAP (TYP. OF
TWO PER LP. G. CYLINDER
TANK) W/ 1/2' z 6' EXP.
3OLT U. END
PATIO ANCHOR WITH EXPANSION BOLT
MODEL # MICS2, PART / 59124,
BOLT NUT MODEL / B1SB, PART
59135
G 120 GAL. PROPANE TANK PAD PLAN
SHB NOT TO SCALE
Da
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL
DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR
OMISSIONS. NO VARIATIONS OR MODIFICATIONS TO WORK
SHOWN SHALL BE IMPLEMENTED WrrHOUr PRIOR WRITTEN
APPROVAL ALL PREVIOUS ISSUES OF THIS DRAWING ARE
SUPERCEDED BY THE LATEST REVISION. ALL DRAWINGS
AND SPECIFICATIONS REMAIN THE PROPERTY OF
ITT CORPORATION, AES, HERNDON VA 20170.
LiOCOLc 4
ITT
W Engmwred for life
Ahan"d –III' -1/! ia6Moimill,
12975 Woddgate Drive
Herndon, VA. 20170
Notice:
TIM oo,.l mndvn mean DW Klan iikMaOni
II may not oo mproduc , or informant Nara In
dlsa a..iinn�i wm�n wsemorin enrp. nEs.
H AZ E LT I N E/ I TTS V 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAANBr PP
ATC JOB NO.: 81388
cAGECODE 9M715
J
DRAWING NUMBER:
0
RR
4339611
ry
0
I
SCALE
sacT 8 a 18
NONE
Z
O
U
z
O
Q
J
0
�I
J
q., J
f'—^
R
J.:•.
c
Specificati
under Toy
i,cnse
x
'..,•:,. ti of
LiOCOLc 4
ITT
W Engmwred for life
Ahan"d –III' -1/! ia6Moimill,
12975 Woddgate Drive
Herndon, VA. 20170
Notice:
TIM oo,.l mndvn mean DW Klan iikMaOni
II may not oo mproduc , or informant Nara In
dlsa a..iinn�i wm�n wsemorin enrp. nEs.
H AZ E LT I N E/ I TTS V 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAANBr PP
ATC JOB NO.: 81388
cAGECODE 9M715
or
DRAWING NUMBER:
Sa
RR
4339611
D
0
I
SCALE
sacT 8 a 18
NONE
or
IY�!•
MOPE
I
SUPPORT POST CAP
30,
/
\\
(MIN)
Z
1
I
O
1
2 FT. HORSE WAD W/U-BOLTS
FOR 3 1/2)- W PPE
m
1
z
UNIVERSAL
CABLE LADDER
TWO (2) PROPOSED
fR GPS ANTENNA -e
FT MIN SEPARATgN FOR'
H -FRAME REMOVED
I
I
(COMIEGT_10.
.-.
Q
KIT
BETWEEN GPS FOR CLARITY
1
/
J
'
REFER TO SHEET 17
\
/
�
DETAIL C Ff32
DTE
/2A
O' x 2+• WIDE 12
GAUGE GRIP STRUT
I
GROUND BAR DETAILS
T -BRACKET TO
SUPPORT 1/2"
z
(h OWER MEMBER
/2 AWG TINNED
02 INSULATED
;I (TEM
SOLD COPPER
COAX JUMPERS COPPER JUMPERS
x
a
f f
z
24• WIDE 7W0
Cl)
0
£
TWO (2) 12 GROUND
TIER TRAPEZE
¢
o
WIRE N G1WlEX
KD (TEM
<
)6 INSULATED GROUN
CONDUITSEALED
1
•
LEADS FROM COAX
LCADWELD )
o
GROUND
TWO HOLE LONG
EQUIPMENT
GRWND R
I ('rX
BARREL COMPRESSION
CABINET
3 1/2- STD PIPE
SEE DETAIL 'C' SHEET 17
o
LUG TERMINATED ON
LOCATION/
CuKITS
GROUND BAR (MGB)
521
SORIENTATION
PECIFIC TO SITE
T O GROUND RING (TVP)
1
1/2• JUMPERS NOT
CONDITIONS
(hSTACKABLE
TO EXCEED 6'
SNAP -IN
INSTALLED WITH DRIP
HANGERS
LOOP
a
'r
<°
— — — — — -- — — — — ----
Y
(2) /2 TINNED
GO
SEE SHEET 17
SOLD COPPER
1/2" FLEXIBLE J2 TINNED SOLID ,1
I_
GROUND
CONDUIT ATTACHED COPPER GROUND LEADS
ADS
.-.FOR
NOTE, REFER TO COAX
BAR DETAIL
TOWER TYPE TO
TO ICEBRIDGE POST (1) FROM CABINET ITH
NO TO SCALE
RING AND MOUNTING
DETAIL TO SHEET 3.
REFLECT SPECIFIC
W PIPE CLAMPS, TWO HOLE LONG BARREL
(2) ROUND COMPRESSION LUG, (1)
A
SITE
SOLDFORT
O FROM RF IN PLATE TO
BY CODES
PROPOSED
LEADS FROM MGB GROUND RING
PROPOSED CABLE BRIDGE
WAVEGUIDE LADDER
FRONT ELEVATION
�
B
G
SH9
SH9 NOT TO SCALE
SH9 NOT TO SCALE
All ANTENNA AND COAXIAL
GPS ANTENNA BULLET
CABLE TO BE INSTALLEDBY
III TRIMBLE P/N
CONTRACTOR
K
57860-70 (F)
NEED METAL TRACER
WASHED GRAVEL
CONNECTOR
NEED TWO (2) GPS ANTENNAS
OR EQUIVALENT
NOTES:
MARKING TAPE
4" OF COMPACTED
VERIFY DIPS AND SNF �E
CRUSHED CONCRETE OR
FOR WEATHERPROOFING)
I
OF)� DIRECTION
1. LEAN CONCRETE, RED -COLORED TOP,
FINISHED GRADE. OR
TRENCH LIMESTONE
USE STANDARD METHODS,
;
OF SATF111IE FOR CI.FAR NLIY
MAY BE USED IN PLACE OF
GROUND COVER MATCHCAUTIONARY
TAPE
W NOT USE COLD
'
I
COMPACTED SAND.
LOPE AND THICKNESS OF
COMPACTED BACKFILL
SHRINK
FIELD VERIFY
2. CONDUIT SIZE, TYPE, QUANTITY AND
EXISTING
W/ SATISFACTORY NATIVE OR
DISTANCE WITH
3
SEPARATION DIMENSION TO BE
UNDISTURBED SOIL
IMPORTED SOIL
ANTENNA MOUNT WEST
UCTION MANU,ER
VERIFIED WITH LOCAL UTILITY
FINI
MARINA P/N 534628 OR
2
COMPANY REQUIREMENTS
EQUAL
(TYP
ZTOP
cryp.
3. CONTRACTOR TO USE SCHEDULE
—,li— - — TELEPHONE CONDUITS &
Y SID. WT PIPE
F CABLE BRIDGE
I)
80 GALV. PIPE UNDER ALL
a
_i j = -- = =ANTENNA SHARING
%
TRAFFIC CONDITIONS
-j I il_ _ _,_ __-.- �I I WHERE APPLICABLE '
i•
—_ COMPACTED SAND OR
/
4. ALL CONDUITS ABOVE GRADE TO
- - �<. SIMILAR MATERIAL AS
-
3
BE FIGS. TRANSITION FRON RNC
�_�;
II—III REQUIRED BY MUNICIPAL
BUTTERFLY HANGER
I
TO RGS TO BE BELOW GRADE
_
CODE
TESSCO P/N 762965
OR EQUAL
i
GAV. STEEL PIPE FOR
T(2)
5. BACKFILL TO BE COMPLETED
`r =` - "^= ELECTRICAL CONDUITS
CABLE BRIDGE
}2 TINNED
-_.D FABRIC
COPPER
IN 12" LIFTS AND TAMPER
j- �_I—`MIRAFI
BETWEEN LIFTS.
II 50OX
6"
MIN. "—
KEY NOTES:
6. EXCAVATED SOIL SHALL BE
(TYP) TYPICAL FOR ENTIRE LEASE AREA
O1 COAX CABLE
STORED AS NOT TO CONTAMINATE
COMPOUND.
GPS COAX CABLE
O2 COAX CABLE GROUNDING KIT
WITH SEALTITE
CONTRACTOR SHALL COMPACT FILL TO 95% DENSITY
O3 COAX CABLE SUPPORT ASSEMBLY
7. IF EXCAVATION WILL BE LONGER THAN
USE U -BOLTS FOR
A WORK DAY, TRENCH AND SOIL
MOUNTING GPS TO PIPE
O GROUND BAR
MUSH BE COVERED.
AWG GND =
'.
COAX GROUNDING
TELCO AND POWER
DRAWINGS.DO NOT SCALE
DIME SIONS AND ADVISE CONSULTAANTSROFUANY ERRORS ALL
/j2
GPS MOUNTING
DETAIL
DETAIL
DIRECT BURIED CONDUITS
OMISSIONS. NO VARIATIONS TE MODIFICATIONSWITHOUPRI TO WORK
OMISSIONS.
SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN
/ U L
E
F
APPROVAL. ALL PREVIOUS ISSUES OF THIS DRAWING ARE
SHB NOT TO SCALE
SH9 NOT TO SCALE
SH9
SUPERCEDED BY THE LATEST REVISION. ALL DRAWINGS
NOT TO SCALE
AND SPECIFICATIONS REMAIN THE PROPERTY OF
IT CORPORATION, AES, HERNDON VA 20170.
IY�!•
MOPE
/a 9 License 4
EWA
TAT
Wd fn fft"I N • fabFFWaa
12975 Woddgate Drive
Herndon, VA. 20170
ms doament contaiis ampany prnrnAary nbrmalHn
It may not De reproduced, or Infim,afik Nere in
discbsed wlltpot w ' consent of ITT Core. AES.
HAZELT I N E/ ITTS V 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAWNBV: PP
ATC XOB NO.: 81388
CAGECODE 9M715
DRAWING NUMBER: SIZE. REV:
433961K3 D 2
SCALE:
am9 a 18 NONE
T?•:e I
I
Z
O
U
z
O
Q
J
----.._.CTT--.:vpccil
/a 9 License 4
EWA
TAT
Wd fn fft"I N • fabFFWaa
12975 Woddgate Drive
Herndon, VA. 20170
ms doament contaiis ampany prnrnAary nbrmalHn
It may not De reproduced, or Infim,afik Nere in
discbsed wlltpot w ' consent of ITT Core. AES.
HAZELT I N E/ ITTS V 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAWNBV: PP
ATC XOB NO.: 81388
CAGECODE 9M715
DRAWING NUMBER: SIZE. REV:
433961K3 D 2
SCALE:
am9 a 18 NONE
T?•:e I
#'2 SOLID TINNED GROUND
A/C UNI
LEFT SIDE
TELCO
ENTRY
RF
RIGHT SIDE VIEW
ANTENNA GROUND
02 SOLID TINNED GROUND
(1) 2- CONDUIT
POWER PENETRATION
POINT
(1) 2- CONDUIT AND
(2) 1- CONDUIT
TELCO PENETRATION
POINT
INSTALL ITT PROVIDED
GASKET BETWEEN CABINET
BASE AND CONCRETE PAD
FRONT ELEVATION
HITT
redfo
!m I
Al
29'
few
I8
o � A~ o
INSTALL ITT PROVIDED
GASKET BETWEEN CABINET
BASE AND CONCRETE PAD
FRONT ELEVATION
/2 SOLID
TINNED GROUND
LEFT SIDE VIEW
RF PENETRATION POINT
UNIT
RIGHT SIDE
CONDUIT BODY MUST
CLEAR 3" FLANGE
BELOW
POWER
ENTRY
ITT PROVIDED
TELCO BOARD
4X 0'j'
A/C/UNIT
6' -14 -
FRONT
PLAN VIEW
tkDOOR
2'-6' DOOR
SWING, TYP
ITT PROVIDED
PANEL
2'-4j1' 2 -1 Cj
A/C UNIT
R'l
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL
DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR
EQUIPMENT CABINET DETAILS OMISSKINS. NO VARIATIONS OR MODIFICATIONS TO WORK
A SHOWN SHALL BE IMPLEMENTED WM40UT PRIOR WRITTEN
APPROVAL ALL PREVIOUS ISSUES OF THIS DRAWING ARE
SHf "oT TO �Z SUPERCEDED BY THE LATEST REVISION. ALL DRAWINGS
AND SPECIFICATIONS REMAIN THE PROPERTY OF
ITT CORPORATION, AES, HERNDON VA 20170.
u�
S
J
ON
I..L
F_
Z
O (
U z
O
Q �
J C)
specif
U) ._ r
Z
HITT
redfo
NOTE:
12975 Woddgate Drive
Herndon, VA. 20170
1. GROUNDS TO BE 2 HOLE LUGS CRIMPED WITH 3/8 SS HARDWARE.
Tnls Ox"a.I mnaim cmpay p'cprebry nfama4m
II may not b reprWuC . or infamution M1H¢ in
Oisd a, without wmwo consent of ITT Cor,. AES.
2. CONDUIT STUB—UPS NEED TO BE INSERTED AS STRAIGHT AS POSSIBLE, NO EXPOSED
HAZELTINE/ITTSV 173-21
2290 LYMAN RD
GROUNDING OR CABLE MATERIALS PERMITTED AS TO ELIMINATE TRIPPING HAZARDS.
DRAWN RY: PP
3. ORIENTATION OF FINAL CABINET INSTALL WILL BE DETERMINED BY THE MOST DIRECT RF
CAGE CODE I 9M715
PATH IN (SHORTEST ROUTE TO RAD CENTER).
4339611 D 0
I
/2 SOLID
TINNED GROUND
LEFT SIDE VIEW
RF PENETRATION POINT
UNIT
RIGHT SIDE
CONDUIT BODY MUST
CLEAR 3" FLANGE
BELOW
POWER
ENTRY
ITT PROVIDED
TELCO BOARD
4X 0'j'
A/C/UNIT
6' -14 -
FRONT
PLAN VIEW
tkDOOR
2'-6' DOOR
SWING, TYP
ITT PROVIDED
PANEL
2'-4j1' 2 -1 Cj
A/C UNIT
R'l
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL
DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR
EQUIPMENT CABINET DETAILS OMISSKINS. NO VARIATIONS OR MODIFICATIONS TO WORK
A SHOWN SHALL BE IMPLEMENTED WM40UT PRIOR WRITTEN
APPROVAL ALL PREVIOUS ISSUES OF THIS DRAWING ARE
SHf "oT TO �Z SUPERCEDED BY THE LATEST REVISION. ALL DRAWINGS
AND SPECIFICATIONS REMAIN THE PROPERTY OF
ITT CORPORATION, AES, HERNDON VA 20170.
u�
S
J
ON
I..L
F_
Z
O (
U z
O
Q �
J C)
specif
U) ._ r
Z
M of
d ect
HITT
redfo
•ova nwd 0 . &seb.e..
12975 Woddgate Drive
Herndon, VA. 20170
Notice:
Tnls Ox"a.I mnaim cmpay p'cprebry nfama4m
II may not b reprWuC . or infamution M1H¢ in
Oisd a, without wmwo consent of ITT Cor,. AES.
HAZELTINE/ITTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAWN RY: PP
ATC,D9 ND.: 81388
CAGE CODE I 9M715
DRAWING NUNfiER: SIZE: REV:
4339611 D 0
I
SCALE:
am 10 a 18
NONE
M of
d ect
CONCRETE NOTES
1. UNLESS OTHERWISE NOTE, ALL CONCRETE SHALL
DEVELOP A MINIMUM COMPRESSIVE STRENGTH OF 5000
P.S.I. IN 3 DAYS
2. ALL EXPOSED EXTERNAL CORNERS OF CONCRETE ARE TO
BE CHAMFERED.
3. THE CONTRACTOR SHALL REFER TO DRAWINGS OF OTHER
TRADES AND VENDOR DRAWINGS OF EMBEDDED ITEMS AND
RECESSES.
4. THE CONTRACTOR SHALL VERIFY ALL SIZES AND LOCATIONS
OF ALL ELECTRICAL OPENINGS AND EQUIPMENT PADS WITH THE
ELECTRICAL OPENINGS AND EQUIPMENT DETAIL AND SHOP
DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO PROVIDE ALL OPENINGS AND SLEEVES FOR
PROPER DISTRIBUTION FOR ALL UTILITIES.
5. POWER AND TELCO CONDUITS TO BE GALVANIZED RIGID AT
CONCRETE PENETRATION POINTS TRANSITIONING TO FLEX TO THE
CABINET TERMINATION POINTS.
6. ALL CONDUITS LEADING TO THE H -FRAME COMPONENTS MUST BE
RIGID GALVANIZED.
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL
DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR
OMISSIONS, NO VARIATIONS OR MODIFICATIONS TO WORK
SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN
APPROVAL. ALL PREVIOUS ISSUES OF THIS DRAWING ARE
SUPERCEDED BY THE LATEST REVISION. ALL DRAWINGS
AND SPECIFICATIONS REMAIN THE PROPERTY OF
IT CORPORATION, AES, HERNDON VA 20170.
18"X 12'X 6'NEMA
3R JUNCTION BOX
4' WATERPROOF��
BOX
3' DIA. GALV. PIPE
NOTE: SEE SHEEP
15 FOR CONDUrt
ROUTING
JUNCTION BOX DETAIL
SH71 NOT TO SCALE
03/4' CONDUIT
AND CABINET
GND (1)
02' CONDUIT
01' CONDUIT
01' CONDUIT
75.
DETAIL G
NOT TO SCALE
23'-6 5/8' TO
SLAB EDGE
23.
88 1' 115.
TELCO CONDUIT STUB UPS
THRU PAD - SEE DETAIL G
(10' THICK 5000 PSI CONCRETE
SLAB WITH 6' X 6" #9 WIRE MESH
AND TWO (2) #5 REBAR AROUND
THE PERIMETER)
ICON
OUTLINE OF NEW EQUIPMENT CABINET. (1) GND FOR IC
WHEN REQUIRED TO ROTATE CABINET 180' BRIDGE POST
ABOUT CABINET CENTER, TELCO AND
'OWER STUB UPS MUST ROTATE, AS WELL. 2 1/4' HANDLE
ON DOOR
OUTLINE OF LPG GENERATOR
7" X 7' CUTOUT THRU CONCRETE SLAB
(CENTERED WITH JUNCTION BOX)
1
7S, 3'-6 5/8" TO
BB SLAB EDGE
POWER CONDUIT STUB UPS
THRU PAD - SEE DETAIL H
SEE DETAIL I 01R' CONDO
20' 0' 03/4'
H -FRAME 3'-2 3/ ' '-2 3/4' 2�' CABINET
GN(D AND
POL10' X 13' EQUIPMENT GND (1)ASER
GND (ll
PAD INAIO'%15'
ISE AREA DETAIL H
n n NOT TO SCALE
0 3 ;� 3 O\ %� POST BASE FOR
E Q CABLE/ICE BRIDGE
9 0
I4-FRAME
n
3'-6j' TO
T.C.L. O O
" O
1
3' 30-3/4' 30-3/4; 3' 'o
o1)¢' CONDUIT
" 02 SOLID TINNED GND
LEAD INSIDE SILICONE I
nGB
GNDS EX(ED CARFLEX FOR M
2) AND POST GND (1) I
I N
HITT
for h*
Amend yYOnIY/ A MIMOw
12975 Woddgate Drive
Hemdon, VA. 20170
Notice:
ThisEMumenl contains[w -yDmprklary'mtomaGDn
II may not be reDrDtluvytl, or infarmatan Mre in
tli5dos V wilOaul wrllten COnsenl of ITT Corp. NES.
HAZELT I N E/ITTS V 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAWN By PP
ATC JOB NO.: 81388
CAGE CODE 9M715
DRAWINGNUMBER: SIZE REV:
433961K3 D 0
SCALE:
aeTT 11 a 18 NONE
DETAIL I - POST BASE
s""
NEW
(POWER SIDE)
2'-6' 2'-6' 2'-0' 3'-0' POWER AND FUEL
EQUIPMENT CABINET
18' % 12' X 6" NEMA 3R JUNCTION BOX
INSTALL FLUSH WITH TOP OF GENERATOR USING
STUB UP GENERATOR
1 5/8' UNISTRUT CHANNEL AND POST BASES
LPG GENERATOR
ELEV. +6 AGI
OR EQUIVALENT - TBD BY CONTRACTOR
CABINET BASE FRAME
10' THICK 5000 PSI CONCRETE
(SPLIT OVER 7' X 7' CUTOUT)
D D
INSTALL ITT PROVIDED GASKET
GENERATOR BASE FRAME
SLAB WITH 6' X 6" }9 WIRE MESH
SH1 SH11
(TWO (2) /5 REBAR
BETWEEN CABINET AND PAD
O
FOUNDATION LAYOUT PLAN
NOTE:
THE PERIMETER)
A
SEE
MANUFACTURE'S SPECIFICATIONS
SH71 NOT TO SCALE
FOR
EXACT BOLT HOLE LOCATION
13'-0' (LONGEST DIRECTION)
AND
QUANTITY
HITT
for h*
Amend yYOnIY/ A MIMOw
12975 Woddgate Drive
Hemdon, VA. 20170
Notice:
ThisEMumenl contains[w -yDmprklary'mtomaGDn
II may not be reDrDtluvytl, or infarmatan Mre in
tli5dos V wilOaul wrllten COnsenl of ITT Corp. NES.
HAZELT I N E/ITTS V 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAWN By PP
ATC JOB NO.: 81388
CAGE CODE 9M715
DRAWINGNUMBER: SIZE REV:
433961K3 D 0
SCALE:
aeTT 11 a 18 NONE
NEW
O�/
EQUIPMENT CABINET
L.L.
TOP CONC. SLAB
NEW EQUIPMENT
LPG GENERATOR
ELEV. +6 AGI
(6' X 6' #9 WIRE MESH)
CABINET BASE FRAME
10' THICK 5000 PSI CONCRETE
00
INSTALL ITT PROVIDED GASKET
GENERATOR BASE FRAME
SLAB WITH 6' X 6" }9 WIRE MESH
z
(TWO (2) /5 REBAR
BETWEEN CABINET AND PAD
O
AND TWO (2) #5 REBAR AROUNDAROUND
THE PERIMETER)
TOTAL OF (8)
THE PERIMETER
lo' -O'
REDHEAD TRUBOLT
13'-0' (LONGEST DIRECTION)
REFER TO
WEDGE ANCHORS EMB. OR
3/4' CHAMFERED
FINISH GRADE
MANUFACTURER'S
APPROVED EQUAL
EDGE
-
SPECS FOR SIZE AND
-III ••
_
•` f
'.
QUANTITY. MIN 4 2
INTO CONIC. SLAB
I
e
=III III
III -III �I-III III -III
III-
EMBEDMENT HILTI HVA
X57 WASHED STONE
BOLTS INTO CONIC.
MATERIAL ON LANDSCAPE
WEED BARRIER ON WELL
SLAB
10' THK. CONC.
COMP. FILL
9' MIN
PROPOSED 10' THK.
FOUNDATION SECTION
6' MINIMUM 95%
DENS" AN&
CONC. SLAB
GENERATOR ANCHOR DETAIL
a:)
EQUIPMENT CABINET
B
TO SCALEATTACHMENT
COMPACNOT
DETAIL
SCALE 3/4'=1'-0' (BASED ON 22x34 PAPER SIZE)
C
SCALE 3/8"=1'-0' (BASED ON 1107 PAPER SIZE)
SH11
HITT
for h*
Amend yYOnIY/ A MIMOw
12975 Woddgate Drive
Hemdon, VA. 20170
Notice:
ThisEMumenl contains[w -yDmprklary'mtomaGDn
II may not be reDrDtluvytl, or infarmatan Mre in
tli5dos V wilOaul wrllten COnsenl of ITT Corp. NES.
HAZELT I N E/ITTS V 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAWN By PP
ATC JOB NO.: 81388
CAGE CODE 9M715
DRAWINGNUMBER: SIZE REV:
433961K3 D 0
SCALE:
aeTT 11 a 18 NONE
O�/
L.L.
Z
00
U
z
O
J
II
e
HITT
for h*
Amend yYOnIY/ A MIMOw
12975 Woddgate Drive
Hemdon, VA. 20170
Notice:
ThisEMumenl contains[w -yDmprklary'mtomaGDn
II may not be reDrDtluvytl, or infarmatan Mre in
tli5dos V wilOaul wrllten COnsenl of ITT Corp. NES.
HAZELT I N E/ITTS V 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAWN By PP
ATC JOB NO.: 81388
CAGE CODE 9M715
DRAWINGNUMBER: SIZE REV:
433961K3 D 0
SCALE:
aeTT 11 a 18 NONE
ELECTRICAL REFERENCE NOTES
1.GENERAL
1. ALL SAFTEY GROUNDING OF THE ELECTRICAL EQUIPMENT SHILL BE CARRIED OUT IN ACCORDANCE WITH
1. EXAMINE THE SITE CONDITIONS VERY CAREFULLY AND THE SCOPE OF THE PROPOSED WORK TOGETHER
4. UNLESS NOTED OTHERWISE, ALL LUGS SHALL BE TIN PLATED COPPER, TWO -HOLE, LONG BARREL,
WITH THE WORK OF ALL OTHER TRADES AND INCLUDE IN THE BID PRICE, ALL COSTS FOR WORK SUCH
COMPRESSION TYPE.
AS EQUIPMENT AND WIRING MADE NECESSARY TO ACCOMMODATE THE ELECTRICAL SYSTEMS SHOWN AND
3. ALL GROUND LUG AND COMPRESSION CONNECTIONS SHALL BE COATED WITH AND -OXIDANT AGENT,
SYSTEMS OF OTHER TRADES.
5. CONDUCTOR LENGTHS SHALL BE CONTINUOUS FROM TERMINATION TO TERMINATION WITHOUT
2. SUBMITTAL OF BID INDICATES THAT THE CONTRACTOR IS COGNIZANT OF ALL JOB SITE CONDITIONS AND
SPLICES. SPLICES ARE NOT ACCEPTABLE. IF SPLICES ARE UNAVOIDABLE, PRIOR APPROVAL FROM
WORK TO BE PERFORMED UNDER THIS CONTRACT.
THE ENGINEER WILL BE REQUIRED.
3. PERFORM DETAILED VERIFICATION OF WORK PRIOR TO ORDERING THE ELECTRICAL EQUIPMENT AND
COMMENCING CONSTRUCTION. ISSUE A WRITTEN NOTICE TO TIT CORP. OF ANY DISCREPANCIES.
4. OBTAIN ALL PERMITS, AND PAY ALL ASSOCIATED FEED AND SCHEDULE ALL INSPECTIONS.
5. PROVIDE ALL LABOR, MATERIEL EQUIPMENT, INSURANCE, AND SERVICES REQUIRED TO COMPLETE THIS
PROJECT IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND PRESENT IT AS FULLY OPERATIONAL TO
THE SATISFACTION OF THE OWNER.
6. CARRY OUT ALL WORK IN ACCORDANCE WITH ALL GOVERNING STATE, COUNTY AND LOCAL CODES AND
O.S.HA
7. PRIOR TO BEGINNING ANY WORK, COORDINATE ALL POWER AND TELCO WORK WITH THE LOCAL UTILITY
COMPANY AS IT MAY APPLY TO THIS SITE. ALL WORK IS TO COMPLY WITH THE RULES AND REGULATIONS
OF THE UTILITIES INVOLVED.
8. FABRICATION AND INSTALLATION OF THE COMPLETE ELECTRICAL SYSTEM SHALL BE DONE IN A FIRST
CLASS WORKMANSHIP PER NEGA STANDARD 1-2000 BY QUALIFIED PERSONNEL, EXPERIENCED IN SUCH
WORK AND SHALL SCHEDULE THE WORK IN AN ORDERLY MANNER SO AS NOT TO IMPEDE THE
PROGRESS OF THE PROJECT.
9. DURING PROGRESS OF THE WORK, MAINTAIN AN ACCURATE RECORD OF THE INSTALLATION OF THE
ELECTRICAL SYSTEMS, LOCATING EACH CIRCUIT PRECISELY AND DIMENSIONING EQUIPMENT, CONDUIT AND
CABLE LOCATIONS. UPON COMPLETION OF THE INSTALLATION, TRANSFER ALL RECORD DATA TO BLACK
UNE PRINTS OF THE ORIGINAL DRAWINGS AND SUBMIT THESE DRAWINGS AS RECORD DRAWINGS TO TIT
CORP.
10. THE COMPLETED JOB SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER THE DATE OF JOB
ACCEPTANCE BY THE OWNER, ANY WORK, MATERIAL, OR EQUIPMENT FOUND TO BE FAULTY DURING THAT
PERIOD SHALL BE CORRECTED AT ONCE UPON WRITTEN NOTIFICATION, AT THE EXPENSE OF THE
CONTRACTOR.
11. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR REQUESTING CONNECTION OF THE COMMERCIAL POWER
FROM THE POWER COMPANY. THE ELECTRICAL CONTRACTOR SHALL COORDINATE THIS WORK WITH THE
GENERAL CONTRACTOR.
12. THE ELECTRICAL CONTRACTOR IS TO COORDINATE THE EXACT TELEPHONE REQUIREMENTS AND SERVICE
ROUTING WITH THE LOCAL TELEPHONE COMPANY. APPLY FOR TELEPHONE SERVICE IMMEDIATELY UPON
AWARD OF THE CONTRACT.
2. BASIC MATERIALS AND METHODS
1. ALL ELECTRICAL WORK SHALL CONFORM TO THE CURRENT EDITION OF THE NEC ACCEPTED BY THE
LOCAL JURISDICTION, AND TO THE APPLICABLE LOCAL CODES AND REOULATIONS.
2. ALL MATERIALS AND EQUIPMENT SHALL BE NEW. MATERIALS AND EQUIPMENT SHALL BE THE STANDARD
PRODUCTS OF MANUFACTURER'S CURRENT DESIGN. ANY FIRST CLASS PRODUCT MADE BY A REPUTABLE
MANUFACTURER MAY BE USED PROVIDING IT CONFORMS TO THE CONTRACT REQUIREMENTS AND MEETS
THE APPROVAL OF ITT CORP AND THE OWNER.
3. ARRANGE CONDUIT, WIRING, EQUIPMENT, AND OTHER WORK GENERALLY AS SHOWN, PROVIDING PROPER
CLEARANCES AND ACCESS. CAREFULLY EXAMINE ALL CONTRACT DRAWINGS AND FIT THE WORK IN EACH
LOCATION WITHOUT SUBSTANTIAL ALTERATION. WHERE DEPARTURES ARE PROPOSED BECAUSE OF FIELD
CONDITIONS OR OTHER CAUSES, PREPARE AND SUBMIT DETAILED DRAWINGS FOR ACCEPTANCE.
4. THE CONTRACT DRAWINGS ARE GENERALLY DIAGRAMMATIC AND ALL OFFSETS, BENDS, FIFDNGS AND
ACCESSORIES ARE NOT NECESSARILY SHOWN. PROVIDE ALL SUCH ITEMS AS MAY BE REQUIRED TO FIT
THE WORK TO THE CONDITIONS.
5. MAINTAIN ALL CLEARANCES AS REQUIRED BY THE NEC.
6. SEAL AROUND CONDUCTS AND AROUND CONDUCTORS WITHIN CONDUCTS ENTERING THE PREFABRICATED
SHELTER WHERE PENETRATION OCCURS WITH A SILICONE SEALANT TO PREVENT MOISTURE PENETRATING
INTO THE BUILDING.
7, SILICONE SEAL AROUND ALL BOLTS AND SCREWS USED TO SECURE EQUIPMENT TO THE EXTERIOR OF
THE BUILDING.
8, MAKE NECESSARY CONNECTIONS FOR THE BATTERY IN EMERGENCY LIGHT FIXTURE. CONNECT THE
EXTERIOR UGHT FIXTURE, (PROVIDED BY SHELTER MANUFACTURER) TO THE EXTERNAL JUNCTION BOX.
9. ALL CAT 5 CABLES QTY (2) TO BE OSP WEATHER PROOF, LABELED TI AND TIB AT BOTH ENDS. LEAVE
6' UNCUT LOOP INSIDE DEMARK. PULL THROUGH ITT TELCO BOX LEAVING 3' UNCUT LOOP, THROUGH TO
THE CABINET LEAVING 10' UNCUT LOOP. ALL TERMINATIONS TO BE MADE BY OTHERS.
3. CONDUCTORS AND CONNECTORS
1. UNLESS NOTED OTHERWISE, ALL CONDUCTORS SHALL BE COPPER, MINIMUM SIZE /12 AWG, WITH
THERMOPLASTIC INSULATION CONFORMING TO NEMA WC5 OR CROSS POLYETHYLENE INSULATION
CONFORMING TO NEMA WC7., (TYPES THHN OR THWN). INSULATION SHALL BE RATED FOR 90'C.
CONDUCTORS SHALL BE COLOR CODED IN ACCORDANCE WITH NEC.
2. ALL CONDUCTORS USED FOR GROUNDING SHALL BE COPPER AND SHALL HAVE GREEN INSULATION
EXCEPT WHERE NOTED.
3. FOR COPPER CONDUCTORS /6 AWG AND SMALLER, USE 3M SCOTCH -LOC OR 7&B STA-KON
COMPRESSION TYPE CONNECTORS WITH INTEGRAL OR SEPARATE INSULATION CAPS. FOR COPPER
CONDUCTORS LARGER THAN /6 AWG USE SOLDERLESS, IDENT HEX SCREW OR BOLT TYPE PRESSURE
CONNECTORS OR DOUBLE COMPRESSION C -CLAMP CONNECTORS, UNLESS SPECIFIED OTHERWISE ON THE
DRAWINGS.
4. RACEWAYS AND BOXES
1. ALL CONDUIT SHALL BE UL LABELED.
2. ALL EMPTY CONDUCTS INSTALLED FOR FUTURE USE SHALL HAVE A PULL CORD.
3. SHEET METAL BOXES SHALL CONFORM TO NEMA OST; CAST -METAL BOXES SHALL CONFORM TO NEMA 81
AND SHALL BE SIZED IN ACCORDANCE WITH NEC, UNLESS NOTE OTHERWISE.
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL
DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR
OMISSIONS. NO VARIATIONS OR MODIFICATIONS TO WORK
SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN
APPROVAL ALL PREVIOUS ISSUES OF THIS DRAWING ARE
SUPERCEDED BY THE LATEST REVISION. ALL DRAWINGS
AND SPECIFICATIONS REMAIN THE PROPERTY OF
IIT CORPORATION, AES, HERNDON VA 20170.
5. GROUNDING
1. ALL SAFTEY GROUNDING OF THE ELECTRICAL EQUIPMENT SHILL BE CARRIED OUT IN ACCORDANCE WITH
DRAWING NUMBER:
THE CURRENT REVISION NEC.
REV:
2. GROUND LUGS ARE SPECIFIED UNDER SECTION 3 'CONDUCTORS AND CONNECTORS'.
�0�/
LJ.
3. ALL GROUND LUG AND COMPRESSION CONNECTIONS SHALL BE COATED WITH AND -OXIDANT AGENT,
LEGEND
SUCH AS NO -OX, NOALO%, PENETROX, OR KOPRSHIELD.
NONE
4. GROUND ALL EXPOSED METALLIC OBJECTS ON BUILDING EXTERIOR, INCLUDING THE BUILDING TIE DOWN
SYMBOL
DESCRIPTION
Q
CIRCUIT BREAKER
BRACKETS.
5. PROVIDE LOCK WASHERS FOR ALL MECHANICAL CONNECTIONS FOR GROUND CONDUCTORS. USE
a
NON -FUSIBLE DISCONNECT SWITCH
STAINLESS STEEL HARDWARE THROUGHOUT.
�
FUSIBLE DISCONNECT SWITCH
6. DO NOT INSTALL GROUND RING OUTSIDE OF THE PROPERTY LINE.
SURFACE MOUNTED PANEL BOARD
Qorf
®
TRANSFORMER
7. REMOVE ALL PAINT AND CLEAN ALL DIRT FROM SURFACES REQUIRING GROUND CONNECTIONS, REPAINT
0
TO MATCH AFTER CONNECTION IS MADE TO MAINTAIN CORROSION RESISTANCE.
®
KILOWATT HOUR METER
B. ALL EXTERIOR GROUNDING CONDUCTORS INCLUDING EXTERIOR GROUND RING SHILL BE /2 AWG SOLID
DENOTES CABLE OR CONDUIT
BARE TINNED COPPER UNLESS NOTED OTHERWISE. MAKE ALL GROUND CONNECTIONS AS SHORT AND
TURNING UP IN PUN NEW
DIRECT AS POSSIBLE. AVOID SHARP BENDS. THE RADIUS OF ANY BEND SHALL NOT BE LESS THE 8'
DENOTES CABLE OR CONDUIT
AND THE ANGLE OF ANY BEND SHALL NOT EXCEED 90'. GROUNDING CONDUCTORS SHALL BE ROUTED
TURNING DOWN IN PUN VIEW
DOWNWARD TOWARD THE BURIED GROUND RING.
JB
JUNCTION BOX
9. BOND ALL EXTERIOR CONDUITS, PIPES AND CYLINDRICAL METALLIC OBJECTS WITH A PENN -UNION GT
SERIES CLAMP, BLACKBURN GW SERIES CAMP OR A BURNDY GAR 3900BU SERIES CLAMP ONLY. NO
®
PULL BOX TO NEC/TELCO STANDARDS
SUBSTITUTES ACCEPTED.
- OHJ -
OVERHEAD UTILITIES
10. ALL GROUND CONNECTIONS SHALL BE APPROVED FOR THE METALS BEING CONNECTED.
- - UGT -
UNDERGROUND TELCO
11. ALL EXTERNAL GROUND CONNECTIONS SHALL BE EXOTHERMICALLY WELDED. ALL EXOTHERMIC WELDS TO
_ - OGP-
UNDERGROUND POWER
EXTERIOR GROUND RING SHALL BE THE PARALLEL TYPE, EXCEPT FOR THE GROUND RODS WHICH ARE
TEE EXOTHERMIC WELDS. REPAIR ALL GALVANIZED SURFACES THAT HAVE BEEN DAMAGED BY
^/
EXOTHERMIC WELDING. USE SPARY GALVANIZER SUCH AS HOLUB LECTROSOL /15-501.
DENOTES REFERENCE NOTE
•
EXOTHERMIC WELD CONNECTION
12. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER WHEN THE BURIED GROUND RING IS
INSTALLED SO THAT THE REPRESENTATIVE CAN INSPECT THE GROUND RING BEFORE TI IS BACKFILLED
■
MECHANICAL CONNECTION (eg LUG, CTAP)
WITH SOIL
'II--
GROUND ROD
13. FOR MEAL FENCE POST GROUNDING, USE A HEAVY DUTY TYPE GROUNDING CLAMP OR EXOTHERMIC
WELD CONNECTION TO THE POST.
'IF -Q
GROUND ROD WITH INSPECTION SLEEVES
Tr
GROUND BAR
14. WHERE MECHANICAL CONNECTORS, (TWO -HOLE OR CLAMP), ARE USED, APPLY A LIBERAL PROTECTIVE
COATING OF AN ANTI -OXIDE COMPOUND SUCH AS 'NO OXIDE A' BY DEARBORN CHEMICAL COMPANY
PIN AND SLEEVE RECEPTACLE
ON ALL CONNECTORS.
----
GROUND CONDUCTOR
ABBREVIATIONS
AFG
ABOVE FINISHED GRADE
6.OVERCURRENT 8 SHORT-CIRCUIT/GROUND FAULT PROTECTION (IF APPLICABLE)
AIC
AMPERE INTERRUPTING CAPACITY
BFG
BELOW FINISHED GRADE
1. THE CONTRACTOR SHALL RECORD LOAD READINGS WHERE SITE POWER ORIGINATES FROM A 30 SERVICE
C
CONDUIT
TO MONITOR AND ASSURE A BALANCE LOAD AT THE PRIMARY SUPPLY. RECORDS SHALL BE PROVIDED
CRGB
CELL REFERENCE GROUND BAR
TO THE SrTE/FACILITY OWNER. THE CONTRACTOR SHALL CONSULT THE MANUFACTURER'S PLANS, SHOP
CU
COPPER
DRAWINGS AND SPECS FOR INDOOR/OUTDOOR EQUIPMENT LOCATIONS AND INSTALUTION.THE ELECTRIC
C/w
D.T.T.
COMPLETE WITH
DRY TYPE TRANSFORMER
SERVICE SHALL BE IN COMPLIANCE WITH ALL RULES AND REGULATIONS OF THE UTILITY COMPANY. THE
EC
EMPTY CONDUIT
ELECTRICAL CONTRACTOR SHALL PROVIDE EQUIPMENT WITH HIGHER SHORT-CIRCUIT FAULT CURRENT
G
GROUND
RATINGS, (kAI.CJ, AS REQUIRED TO MATCH AND EXCEED THE UTILITY COMPANIES AVAILABLE
BE
GROUNDING ELECTRODE
SYMMETRICAL AND ASYMMETRICAL FAULT CURRENT LEVELS. FUSES IN SERVICE SWITCHES SHALL BE
GEC
GROUNDING ELECTRODE CONDUCTOR
-R-/
'R' SUBCLASS RK7CURRENT UNITING TYPE, 200 1A.I.C., NON -TIME DELAY. DISCONNECT
CLASS ' -
SUBCLASS
GRC
GALVANIZED RIGID CONDUCT
SWITCHES ARE TO HAVE REJECTION CLIPS, UNLESS INDICATED OTHERWISE. ELECTRICAL EQUIPMENT AND
MI5
MANUAL TRANSFER SWITCH
PROTECTIONS SHILL BE STANDARD kA-I.C. RATED HIGHER THAN INCOMING EQUIPMENT AND/OR UTILITY
NEC
NATIONAL ELECTRICAL CODE
COMPANY KAI.C. RATE AND CONSIDERING ELECTRIC MOTORS FAULT CONTRIBUTION. THE CONTRACTOR
0/H
OVERHEAD
SHALL NOT BEGIN CONSTRUCTION UNTIL THIS MANDATORY REQUIREMENT IS MEI. IF NEW LOAD IS
PPC
POWER PROTECTION SHELTER
ADDED, THE CONTRACTOR SHALL VERIFY AND CONFIRM BEFORE CONSTRUCTION, THAT THE TOTAL UTILITY
RNC
RIGID NON-METALLIC CONDUIT (SCHEDULE 80 PVC)
SERVICE LOAD SHALL KEEP EQUAL TO. (125X MAX. DEMAND + NEW LOAD) < 80% SERVICE ENTRANCE
Sp
SERVICE DISCONNECT SWITCH
CONDUCTORS/MAIN OVER CURRENT PROTECTION AMAPACITY, WHICHEVER RATING 5 LOWER. LIGHTING
SE
SERVICE ENTRANCE
SHALL MEET NEC, IESNA AND/OR FAA STANDARDS IF APPLICABLE. PHOTO METRIC LEVELS SHALL
SN
SOLID NEUTRAL
COMPLY WITH LOCAL, STATE AND FEDERAL RULES. ALL ELECTRICAL INSTALLATION SHALL MEET ALL
TGB
TELCO GROUND BAR
STANDARD REQUIREMENTS OF THE POWER AND TELEPHONE UTILITY COMPANIES.
TEGB
TOWER EXIT GROUND BAR
TR
TRANSFORMER
TVSS
TRANSIENT VOLTAGE SURGE SUPPRESSOR
TYP
TYPICAL
Wp
WEATHERPROOF - NEMA 3R
U/G
UNDERGROUND
A.
evwe��
_i>
W engi r d'for life
A/rrwl 6MhaeefhM A NtaleMCee
12975 Worldgate Drive
Herndon, VA. 20170
T8 mt mnpa Na infi Vrynfm m
I may rotcerePmtlucM.amialTT C .Mm
uHmaa wltlqut wMlen mcera HITT Cap. AEG.
HAZELTINEATTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAWN BY: PP
ATC JOB NO.: 81 388
CAGE CODE 9M715
DRAWING NUMBER:
SIZE
REV:
433961 K3
�0�/
LJ.
0
I
SCALE:
sm 12 • 18
NONE
Z
0
(D
U
z
0
Qorf
J
0
J
E Al
JL' �
V7l
Z
_i>
W engi r d'for life
A/rrwl 6MhaeefhM A NtaleMCee
12975 Worldgate Drive
Herndon, VA. 20170
T8 mt mnpa Na infi Vrynfm m
I may rotcerePmtlucM.amialTT C .Mm
uHmaa wltlqut wMlen mcera HITT Cap. AEG.
HAZELTINEATTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAWN BY: PP
ATC JOB NO.: 81 388
CAGE CODE 9M715
DRAWING NUMBER:
SIZE
REV:
433961 K3
D
0
I
SCALE:
sm 12 • 18
NONE
20' X 100' PAVED ACCESS DRIVE
(1) PARKI
SPACE
EXISTING CIWNLINK
FENCE W/3 -STRAND
BARBED WIRE
PROPOSED ITT
10' X 13'
EQUIPMENT PAD
WITHIN 10' X 15'
LEASE AREA
` GRAVEL
SURF
PROPOSED ITTGPS (2)
PROPOSED RT_
ATTACHED TO THE ICE
H -FRAME
EXISTING
LESSEE/USER
G4'
0�\O
.�
G
14' X 16'
d
\
SHELTER
- �!
PROPOSED ITTGPS (2)
ATTACHED TO THE ICE
°'\\
BRIDGE IN TWO PLACES
REV:
S' MINIMUM SEPARATION
d
\
71
O
sm 13 a 18
PROPOSED ITT
POWER ROUTING
—PROPOSED ITT
TELCO ROUTING
�s it
\ \ s
�0.
O.
\ Y p
�\ \\ 10' NO SPARK
BUFFER
�C �= PROPOSED 11T
20 GAL
PROPANE TANK
• n
LATTICE
TONER
1\ /
r
A.lb
v
N
B ELECTRICAL PLAN
SH7 SCALE: 1'=5' (BASED ON 24X36 'D' PAPER SIZE)
TRUE NORTH SCALE: 1'=10' (BASED ON 11X17 'B' PAPER SIZE)
PROPOSED ITT
GAS LINE ROUTING
PROPOSED ITT
ICE BRIDGE
`-PROPOSED RT
LP GAS GENERATOR
PROPOSED ITT NEMA
3R 10' X 12' X 6' BOX
)POSED TIT
PROPOSED ITT
3'-6' X 3'-6'
CONCRETE PAD
FOR 120 GALLON
PROPANE TANK
NOTE:
SEE REFERENCE TO PROPOSED CABINET
DETAIL ON SHEET 10 AND ICE BRIDGE
DETAIL ON SHEET 9
J
O
DRAWING NUMBER
I.d_
REV:
I-__
D
71
O
sm 13 a 18
U
z
0
Q
11-40
J
0
W J
V)
ceiticz.,...
ZiJT
0---
_icea_:
r-ws of
License
Engi rr T T
-d,,-,, - -npkw-rhv . •eNnsw
12975 Worldgate Drive
Hemdon, VA. 20170
Notice:
rfsaoa t000 Y amwnr pmo tm nlpnnation
I may not be reproCuw . or information Here In
flsgosatl MIrouI w en mns nt of 0T Cap. AES.
HAZELTI NE/ITTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
F°
81388
CAGE CODE 9 M71 5
DRAWING NUMBER
-SIZE:
REV:
433961K3
D
2
SCALE:
sm 13 a 18
NONE
GNM NO
1. THE CONTRACTOR IS TO ARRANGE AND PAY FOR UNDERGROUND UTILITY LOCATION SURVEYS FOR ALL TRENCHING.
REUSE NATNE BACK FILL AND REINSTATE TO ORIGINAL CONDRION. INSTALL A 6' WIDE METALLIC LINED RED PLASTIC
MARKER TAPE 8" ABOVE ALL BURIED CONDUIT.
2. BOND TO EQUIPMENT SYSTEM WITH A (j2 AWG SOLID TINNED CU WIRE. ADD (2) 5/8" X 8'— 0 DRIVEN GROUND
ELECTRODES 10'— 0 APART FOR MAIN SERVICE GND.
3. APPROXIMATE LOCATION OF #2 AWG SOLID BARE TINNED GND RING. EXACT LOCATION AND NUMBER OF GND RODS TO
BE DETERMINED ON SITE AND BASED ON "FALL OF POTENTIAL GROUND RESISTANCE METHOD' FOR RESISTANCE < 5
OHMS. UNLESS OTHERWISE NOTED, DRIVEN GND RODS ARE TO BE BURIED AT 10 FEET INTERVALS.
4. ALL EXPOSED UNISTRUT IS TO BE COLD SAWN AND RUBBER CAPPED. ALL POWER CABINETS SMALL BE BONDED TO
GROUND RING. WITH TWO HOLE LUGS AND No. 2 TINNED COPPER. ALL GROUNDS FROM GROUND RING SHALL BE
BROUGHT UP IN PVC OR NON METAUC SEAL TYPE, AND EXPOSED END SEALED WITH CAULK,
POWER SIDE DETAIL A NOTE
1A EXISTING UTILITY POLE MOUNTED OR PAD MOUNTED TRANSFORMER. COORDINATE REQUIREMENTS FOR TAP WITH UTILITY
COMPANY.
OSUPPLY AND INSTALL A 100 AMP, 120/240V UTILITY APPROVED METER SOCKET. METER BY UTILITY COMPANY.
PROVIDE WITH MECHANICALLY ATTACHED ENGRAVED IDENTIFICATION LABEL, INDICATING 'ITT METER'.
OPULL (3) g3 AWG THWN AND (1) }8 GND, IN 2" CONDUIT FROM 100A MAIN SERVICE TO MAIN POWER PANEL (MPP).
OPROPOSED H—FRAME, SEE DETAIL ON SHEET A&E TO FILL IN PROPER SHEET A AND DETAIL.
OPULL (3) #6 AWG THWN AND (1) /8 GND IN 2' CONDUIT FROM MPP TO AUTOMATIC TRANSFER SWITCH (ATS).
OPULL (3) 06 AWG THWN AND (1) /8 GND IN 2" CONDUIT FROM ATS TO EQUIPMENT POWER PANEL (PPI).
7A 120/24OV-1-3W, 10QA RATED CB PANEL PPI (EQUIPMENT LOAD CENTER) IN EQUIPMENT CABINET. (SUPPLIED BY ITT
AND CONNECTED BY CONTRACTOR).
OPROVIDE A 100A RATED 120/24OV, 1, 2 POLE 12 SLOT NEMA 3R PANEL BOARD WITH 100A MAIN CIRCUIT BREAKER.
(PART NUMBER: Q01612M125FTRBIO0 WITH PKI2GTA GND KIT).
9A PULL (3) #12 AWG THWN AND (1) N12 GND IN 1' CONDUIT FROM PANEL MPP TO GENERATOR FOR BATTERY
CHARGER AND BLOCK HEATER.
1® PULL (3) %6 AWG THWN AND (1) r8 GND IN 1' CONDUIT FROM ATS TO GENERATOR.
11 PULL (7) /12 AWG THWN AND (1) #12 GND IN 1' CONDUIT FROM ATS TO GENERATOR.
SUPPLY AND INSTALL NEW 10KW 120/240 STAND BY EMERGENCY GENERATOR. INSTALL AS PER MANUFACTURERS
SPECIFICATIONS. DO NOT BOND NEUTRAL TO GND AT THE GENERATOR SYSTEM. NON SEPARATELY
DERNED—COORDINATION.
1® 100A SERVICE ENTRANCE RATED, 2 POLE, NEMA -3R 120/240V ATS (GENERAC RTS OR EQUIVALENT).
14A SUPPLY AND INSTALL NEW 120 GALLON LPG TANK. (UNDER SEPARATE PERMIT). SEE SHEET A&E TO FILL IN PROPER
SHEET M AND DETAII FOR TANK MOUNTING DETAILS.
HALOGEN LIGHT FIXTURE (REGENT PART NUMBER: GPIOOWL OR EQUAL).
1® DUPLEX GFCI OUTLET.
7� %- (MIN) HIGH PRESSURE "POLYPIPE' 24' MIN. UNDERGROUND TO GENERATOR LOCATION HOUSED IN RIGID GALV.
SLEEVE AT CONCRETE PENETRATION POINT. NOTE: THE CONTRACTOR IS TO VERIFY THE EXACT LOCATION OF GAS
ROUTING IN THE FIELD.
TELCO SIDE DETAIL 8 NOTES -
TELCO DEMARCATION POINT. THE ELECTRICAL CONTRACTOR IS TO COORDINATE WITH THE LOCAL TELCO FOR SERVICE
TO EQUIPMENT. INSTALL PULL—ROPE (NO JETLINE OR DRAGUNE).
28 SUPPLY AND INSTALL A NEMA 3R 2'X2' TELCO ENCLOSURE WITH HINGED DOOR AND GROUND BAR.
3B PULL (2) CONTINIOUS OSP CAT 5 CABLES IN 2- CONDUIT FROM DEMARC TO THE ITT TELCO ENCLOSURE AND ONTO
EQUIPMENT CABINET. LEAVE A 6' UNCUT LOOP IN THE DEMARC AND A 10' LOOP IN THE BTS.
4B NEMA 3R 18'X12' BOX. SEE SHEET A&E TO FILL IN PROPER SHEET Y AND DETAL FOR MOUNTING DETAILS.
58 PULL (2) CAT 5, IN 1' CONDUIT, FROM EQUIPMENT CABINET (SCADA) TO NEMA 3R BOX. PULL LOOP THRU NEMA
3R BOX AND CONTINUE TO PROPANE TANK AND GENERATOR. PULL (1) CAT 5 SPARE, IN I' CONDUIT, FROM NEMA
3R BOX TO PROPANE TANK. IDENTIFY AT ALL JUNCTION POINTS AND CABLE ENDS.
6B PULL (6) #14 THWN STRANDED, IN 1' CONDOR, FROM EQUIPMENT CABINET (SCADA) TO NEMA 3R BOX. PULL LOOP
THRU NEMA 3R BOX AND CONTINUE TO ATS.
m0m
1II1
II
II
TR
II
II
I_______________________)I� II 11 --___I
I I
T__ __
n RISER DIAGRAM DETAIL - (POWER SIDE)
NOT TO SCALE
Mo.II�:�II
I I I j
I
I I I _
-v -----------------
31NET)
ILII
II
(FROM EQUIPMENT CABINET) 6B :(FROM
(TO PROPANE TANK)
(TO ATS) 5B EQUIPMENT CABINET)
RISER DIAGRAM DETAIL - (TELCO SIDE)
NOT TO SCALE
I
GND FOR
GENERATOR
GND FOR
JUNCTION BOX
(FROM ATS)
(FROM ATS)
HE
W
J
Z
O
Io z lag L:Ccr,-4
Eng T T
Ihanos101/bMft& ftft�
12975 Worldgate Drive
Herndon, VA. 20170
Notice:
T mm lweain mmoanr Pwieiay lff. n
It may rot oe reproeucea. or information here in
avioz a nnmm..mten mr seN a to C« AES
HAZELTINE/ITTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
CRAWN BY. PP
ATC JOB NO.: 81388
CAGECODE I 9M715
DRAWING NUMBER:
SIZE:
REV.
4339611
D
0
SCALE.
stn 14 a 19
NONE
to r.
m
r �
y�y y�y B
5� k
O
5
ro'.a,n mtTs .,,rtu. IBAY,
o
ro w.n
a e
3
n INTERNAL WIRING
S� NONE
L_ PROPOSED EQUIPMENT
CABINET POWER PANEL
PROPOSED IOOA 240V, �.
SINGLE PHASE UTILITY 3-#3AWG AND 1-/8 AWG
METER SOCKET GROUND IN 2'C
(METER BY UTILITY
3-/3AWG AND 1-/8 AWG
/3-#3AWG AND 1-#8 AWG GROUND IN 2*C
GROUND IN 2'C
a� ONE LINE DIAGRAM
SH1 NONE
EQUIPMENT
PROPOSED 1ODA, 240V, SINGLE
PHASE, 12 SLOT, NEW 3R PANEL
3-f6 AWG AND 1-%8
LOAD DESCRIPTION
BOARD WITH 100A NCO
AWG GROUND IN 1' C
CCT
140.
PANEL 'MMP'
PROPOSED 10KW
LOAD
(kVA)
LOAD DESCRIPTION
MAIN CIRCUIT BREAKER
120/24OV, SINGLE PHASE
100
'1-l3AWG
EMERGENCY GENERATOR
EXISTING UnPOLE
IN 2� C
TBD BY POWER COMP, POWER
1.7
RECTIFIER N0. 1
PROPOSEDLRY
PROPOSED SOURCE OF
�
1.7
RECTIFIER NO. 2
MAIN CIRCUIT BREAKER
0.0
100
3A
3B
ELECTRIC SERVICE
1.7
RECTIFIER NO. 3
20
0.3
SITE OBSTRUCTION LIGHT (IF REQUIRED)
(SURGE SUPPRESSOR)
SPARE (SURGE SUPPRESSOR)
L_ PROPOSED EQUIPMENT
CABINET POWER PANEL
PROPOSED IOOA 240V, �.
SINGLE PHASE UTILITY 3-#3AWG AND 1-/8 AWG
METER SOCKET GROUND IN 2'C
(METER BY UTILITY
3-/3AWG AND 1-/8 AWG
/3-#3AWG AND 1-#8 AWG GROUND IN 2*C
GROUND IN 2'C
a� ONE LINE DIAGRAM
SH1 NONE
EQUIPMENT
LOADCENTER (PANEL
"PP1")
LOAD DESCRIPTION
LOAD
(kVA)
BRKR
SIZE
CCT
140.
PHASE CCT
Tl T2 NO.
BRKR
SIZE
LOAD
(kVA)
LOAD DESCRIPTION
MAIN CIRCUIT BREAKER
0.0
100
1A
1B
O
2A
2B
4A
4B
6A
8B
20
1.7
RECTIFIER N0. 1
20
1.7
RECTIFIER NO. 2
MAIN CIRCUIT BREAKER
0.0
100
3A
3B
20
1.7
RECTIFIER NO. 3
20
0.3
SITE OBSTRUCTION LIGHT (IF REQUIRED)
(SURGE SUPPRESSOR)
SPARE (SURGE SUPPRESSOR)
0.0
20
5A
20
2.4
GFl OUTLET FRONT
A/C UNIT /1
0.9
20
20
0.9
A/C UNIT /2
�A
GFl OUTLET REAR
2.4
20
7B
20
1 0.4
112ovAc OUTLET, INVERTERS
LOAD SUB -TOTAL
3.3
LOAD TOTAL
12.4
1 9.1
1 LOAD SUB -TOTAL
100A MCB, 120/24OV, 10, 3W, 22,000 AIC
TYPES OF LOADS (KVA)
CONNECTED D.F.
DEMAND
CONNECTED 12.4 KVA
DESIGN �� KVA
DEMAND 12.4 KVA
SPARE 11.6 KVA
1
RECEPTACLES 4.8 1.00 4.80
OBSTRUCTION LIGHTING 0.3 1.DO 0.3
EQUIPMENT 7.3 1.00 7.30
TOTAL 12.4 12.40
LOAD 51.7 AMPS 51.7 AMPS
DESIGN 100 AMPS
SPARE 51 AMPS
A PANEL SCHEDULE
SH1 NONE
PROPOSED 100 AMP PANEL SCHEDULE "MPP"
1W NIPS MNN BREWER 1001a,x_ INSTAIIATiDN NEIM 311
12D 40 NOUS LUGS 1 W IMPS L TIDN III URM BACI®ONm
1 PNASE GND. BW X PANEL FEEDER Uni ]EIIDI
3 NPE COINECIED 14.OB KVA
42 POIE SPACES FMS. S METRKAL ANDS 101WC OEWWIA 14A0 m
NOTES:
DESCRIPTION WIRE CON CB. LOAD DEM !TIT!
DEM LOAD CB. WIRE CON DESCRIPTION
AMPS KVA KVA KVA KVA AMPS
EOUPIENr CABINET }3 100-3 12-40 12-40 1 2 Q40 0.40 20-1 3-12 BACI®OUm RECEFV=
.. ] 1 4 1 D.4D OAO I 2 1 1 3-12 1 IaVAmOMmsia;WI
cpv,
supe
State I r
Pnnt j i, ne:_ rmphaai I. iVi
Signa Ul _." `-
Sate: Id1Wal License>i_
�....,....-..l!b,.!1►!FA:w��.,c>.�i:i3��•L:��t�b5)•l.�t 1t�36)•t�3s)• �3�13f'��E.. � .-:, . -ate uu::�n:�-,.:�
UTILITY BACKBOARD PANEL SCHEDULE
NONE
W End for life
AMnOoE1/ & jOtM10i
12975 Woddgate Drive
Herndon, VA. 20170
Notice:
Th. oof�m N m w.M p" ptmtrem., informalion
It may not ne foptoEuc d of information here in
diWtn tl witnout written consent of ITT Cory, AES.
HAZELTINE/ITTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
^RAm Et PP
AIC JOB if- 81388
CAGECODE 9M715
DRAWING NUMBER: ffiE: REV:
4339610 D 0
SCALE:
son 15 tr 18 NONE
or
�__j
LL
Z
O
CD
U
z
O
Q
�+-
J
0
QJ
<
VJ ^
z-..
�peciticat
State I r
Pnnt j i, ne:_ rmphaai I. iVi
Signa Ul _." `-
Sate: Id1Wal License>i_
�....,....-..l!b,.!1►!FA:w��.,c>.�i:i3��•L:��t�b5)•l.�t 1t�36)•t�3s)• �3�13f'��E.. � .-:, . -ate uu::�n:�-,.:�
UTILITY BACKBOARD PANEL SCHEDULE
NONE
W End for life
AMnOoE1/ & jOtM10i
12975 Woddgate Drive
Herndon, VA. 20170
Notice:
Th. oof�m N m w.M p" ptmtrem., informalion
It may not ne foptoEuc d of information here in
diWtn tl witnout written consent of ITT Cory, AES.
HAZELTINE/ITTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
^RAm Et PP
AIC JOB if- 81388
CAGECODE 9M715
DRAWING NUMBER: ffiE: REV:
4339610 D 0
SCALE:
son 15 tr 18 NONE
or
GROUNDING PROTECTION SYSTEM NOTES:
J
1. FR OME YABE ORRICE GIDIAD RA' (ane). 3M A Ii X 1/4b. KIM AT FOOD
CABINET TOM NSDNIAMH BIM CPM PROMM A GK MIG BARD A NWMRM OF m' B3BW
NO
Li
ROBE FEB NEC SHE GID RPC WILL BE ASSAULT AIN OF Y -O' AIMY FROM THE
TO ANTENNA
FOUNDATION LFAESS SAMIN DN DRAING.
_
0
2. BOND FENCE iWT TO GID RC 01 M ENITIERIC i Sir FFi CATS M NST
� NONE. AL U®ID m NREBN SEC= GIOUNE M a AiG GREEN .MLtE1F➢
STANDARD GROUNDING
BIIH A fIFXBL COPPW AURA $IGP IECIVEALY W FlIi11)RBCNLY. IYCIK iW All
�� a Sn tM W iRAIBCp BVD( IS RDWII[IL, FIA30M" LUGS APD IAARWARE CWWR VR nR RIOBL
.11AETE0111E 1p IDNIDC PIPE W��
)T TO
FENCE PW6 BORN 12 FEET a TOIfR igAB11TIXL iW iENNCE PULES BEW)K 1Y. EDWO
S RTSDEI➢
NOTE LOWER GROUND
112 TO UW FENCE RAVE ro.VNi RN6 BXN 50',
S1RE1MtE
ODAR CANE SDE➢
NUMBER OF GROUNDING BARS MAY BAR
3, SONDE ENIPAICE PANEL METER. TEIFRDNE CBNO AK SINE CC,t TO BARD WD
GDMI➢D XD (TOP) ANTENNA (TYP)
MART DEPENDING ON THE TYPE OF
TOWER. ANTENw LOCATIONS AND
RING AS THEY CK55.
J
CONNECTION ORIENTATION, PROVIDE
E FAS" NEG a TM CWF BRIDGE STRUCTURE SHALL BE POMMIALLY BINGED m TE BIRRD
AS REWIRED.
CM TNG. EXOTEIMEALLY KID CWMDIX6 AT POST FOR CIHf BRIDGE SIRITUK AD
SMOWI
'IFFEMSTPUCNDYF
4011< ��
BBQ IRO RNG RACE 5/B• X E ODPPWCUB BIG RDD AT IF NERNB N01D CARE BMIX£
TIMI
(TAP FOR ALL)
SINCILIE.
5. PROMISE DISSECTION SINE AT SERACE (ROODS DOIIERIC CONECTNG CMEST TO
RF 0W GMC
DTRNNa WXAD B.R.
m W AREaW
PROPOSEAVEGUID
ruvEGnDE LADDER
B PRAISE BRAD CMNICIOR(z) ROY TE BARD nlD iWc ro IM ANDAM ATI
SODOMaME
q clDa
WITH
BAP AT PGFT A4T B®E a TCO KIBAN F]R. WJWY E LO N O
Kd1DN a
CROWm m ro
COPPER BM iW LENGT L FINAL
CONDUCTION? IfMf.111 OWL COIWHEN BOOS m C
TO B6
IE BLE TO
ro
BW , TR OXIDIC CABf I6TALIX QOT)OBWLY RIO BOIdNG CD)NO
BON➢ ACROSS ICE BRIDGE SECTION TO EACH NINE (2) TALLIED$ lO+x 1OJEFR
CXBBAEA1XMl SIRUCIME MAT I'-0' IBME Pb AK BOK ro BIARO XD AIG PRO.)E A
R
TOTHERINHE AND TD SUPPORT POSTS WITH No. ZCU XBRE E PA1PDLrs1FAL1N PBI)
PF11 PAI)BGK SbfX.At TINE➢ COPPER AND CADWEL0.
3/f PC SLIDE BIM A gMBU4 WO M 1M CXKRIE iXAMIDK
SECURE m TIER Qi. 4 SCLF-
STANDARD CRS
T. R ND • B' -a LONG COPPER CUB STEEL (COPPER ROOD) ORGANO ROD
SIPPOtfMNIAE
Wim IllB x' W. $PATALLA
KR (TAP)
ONA,
SPOOR. DE INSPECTION S"EEME AT R(2) FE BOND QTERNOR
R
UR AD FRCP COIN AMIENA CABLES
ROU
BURIED GROUND DAG. N6TALL GRWK KO PGR (2) FEET MIN
ROD TWO A
AWAY RAMI
[ABOEi
WHERE ALLOWABLE. MSTALL SO 11Ni iW OF GROUND RW 6 W' BELOW GRADE OR B'
6 30' OR
BELOW FROST UNE WHICHDER 6 DEEPER. RETRO TO GROUND ROD INSPECTIONSUEDE.
NOTE, IRRVEKRIIt DOWING
PETER NSC ICE BRIDGE
TO m BTS PRIOR
DUCT LOCATION AND NUMBER a GROUND WTO BE ESTABLISHED ON SITE AND
ALLOWED
TO CABINET ENTRY
BASED ON 'FAL OF POIFMNL GROUND RESISTANCE MEOW' FOR RESISTANCE < 5
O FEWER
ONSIS UNLESS OMFRWISE NOTED. DRNW GROUND RODS ARE BONDED m THE BURIED
SECTION TELCOA,
R COAX GBL[
GROUND RN; AT 15 FEET 1111i
SCT CRDI)DC NT. TYP
i2 AWG LUG
B ELECTRON EXTRACTOR SMALL TAXE NGI)P RQOOBS a (A0. THE RESMTS MAL IDT ,
. , AAAA..
I NN MKli SDN ONNO CONDUCTOR
XEAIER PMN 5 pB6
EMTDX m sTN.CRRE AND GDVFLD
J/ ATUAIS
PAN GROUNDAT TYD 6 NDDRR
LOWER TOWERl7GROUND BAR
B. AL COIECI TO SYSTFY SXVt , YNR M IEE BIIX BFKS KPVIAL tY 0.r01b M
B6 MR O I2EU AUCETiS Will,
REFER TO SHEET DETAIL
THE F C NT
CN a CURRENT fIAA. T-LgW[LTDI6 BLL XDF g ILpNEp, EMIiPN DOE
LIG,GREEN0
FROM AI➢
NMII ARD [BDLLIWS fRB1 NRDIM
IR S
C FOR GROUND BM DET/JLS
SPECIFIED.
��.
sscrWs rRIIXD Rab m "Na OLAm Ba BM
ALL BODS N MD W$NAL BE MINIMAL. 12' IMMANTBIW CABLES S1WL , BCT)ED—snm
HIB IIB WE FBI10.
CWffB
AT UW DD. RM OEATEB TNN 150• SOUL ,BIDE, l0/AKS WILL Or LENGTH
MICHNIV'E SND Iz TIED SXD COWER
COOKOUTS LOOk" BIM 7011,El1 Olmli PROJECT WIY®
FDI R
[INIAD, BOK TO MUND FIC
GRAM
11. REN VISIONAL CONTRACTOR SIAL Bun TR ND; M EACH OILER AM M GK MC W
FBo PAIRS. DDamIMrz RIM TWEp DONNA'S PROJECT WNCW.
_ _ _ _ _ _ _ _ _ _ _ _ _N\
12. VBRLD DN" CIBIET MD RRE m XO HANG AS SKV" N EOMPEM X) RTAL
13. PROl, WADK BOKIC AAE06 BEINFOI UDI GTE AND POST F SIMM W ORAWBD.
11. CXTPATN $NAL FRAME QOTEIWG KIDIC Ai ALL CRAVED RNG CONNBTDI6,
fRDMD RK TIE DTO EXISTING
T 1Bl PTYPICAU TOKR 4 FROND NN QTSi1N
EXISTING GROUND WIRE
SMJDMUL fglgER iPNE SERVICE P.V]6, IX6TNG LORA XNDK RNOW, AK ADXTIDNUL
GROUND
(L1 M MTE WITH CRN) FRDNDIK
AS ROAMED N
ONTAMDI
GROUND RING
15Glg16
15. CONTRACTOR WALL MIRE MECHANICAL.BINDING AT AL OMENTA SE, ID
NECTS,
FA9AD RW I2 ARE MINES, SOM COPPEt! GRDAO 014. IB• BELOW WADE XN
ALL DISC TL ,NRS,
FD D6CXWLTS, KERS }BX PA' WARDS
BRF4
MAIN IO
AK WM INBW RAMI
D�nTED,GAM DMXA�,� MMALNX
GR Cow,ALL,mm
P
CXMFLIDI6 9M1 , PKWBLY 1ERWWIFD WIM WD )PING Mns ND Baa
SELF—SUPPORTING TOWER
m. CON"ACTOR WNL REWE RVR FRW SEEMS BORE NLWNCVLT MMM;
CONNECTIONS, CONTRACTOR MNL EG' RRH III ALL. POINTS W EWIAT �QN
GROUNDING DETAIL
D¢vRAR PEALS MRY CDO GAYANE W MW PAM AS APRDPRNrz m PEWIT Xldlpl.
E
17, THE 701 QR EROIAID WS BAR (TEGB), $HVL, NSTALLED ,LBW 1M
GROUNDING DIAGRAM
SH16
TRANSMISSION UPS GROUND KIIS, NEAR THE AREA a THE TONT AT THE MAT WTEAE
F
NOT TO SCALE
THE ANTENNA TRANSMISSION ONES TRANSITION FROM THE TOI TO ME CABINETS.
`BABY EXACT IDGIDN OF GROMENG BAP I'm PROPER CONDUCTXP LUNGRL
SH76
NOTE'
GAOUKUNG BAR PROAOED 8Y TM ANIEwU CAGE INSTALLER RNA EXDTERIWC WELD
NOT TO SCALE
FROM ONE BUOYED cRaMwc RM ro WOAD BAA MNL ,TIE R6P, FDR a
Can CmKNATE EOR
THE ELILUE
AHTENIM CAGE NStflo
PER STRUCTURAL /43396122 DATED 06/03/09 INSTALL PROPOSED COAX LINES ON EMPTY
TO
SCHEDULE TO WE CMNECI
CONNECTION. PROM, 1A' POC
h' BEI) IN NEW
WS B
TOWER LEG.
ANIENAW BABE RPSfALIATIOHS FON CONNECTDN , TECO m TOWER (WOUND RIGS.
FO FEW TO GR
OUTSIDE CABINET
TOP OF GRAVEL
x
METALIC BOX,
n
f GRADE
FINISH GRADE COVER
HOUSING ETC.
r
w
30 DEEP INSPECTION
WELL OR EQUIVALENT
BRASS TWO HOLE
ANTENNA CABLE o 12' TO 24'
0�
z EXOTHERMIC
w WELD
MECHANICAL CRIMP
CONNECTOR WITH
- -
(^or
STAINLESS
t
-�
J C I
HARDWARE
WEATHERPROOFING KT
o
�� B� sere g;`°$ F✓e�4� ��
i - ° ° °°' °° —"3/4• CRUSHED STONE
(SEE NOTE 3) #6 AWG STRANDED CU WIRE
WfTH GREEN, 600V, 7HWN
RING GROUND 2
AWG BCW
OR EOUAL FILL TEST
30 R- 1 WELL TO it 8* OF
w TOP
O O
INSULATION (GROUNDED TO
CABLE GROUND KR GROUND BAR) (SEE NOTE 1 S 2)
SOLID, TINNED
NOTES:
m
GROUND ROD COPPER
/2 SOLD BANNED CORP
n
1. DO NOT INSTALL CABLE GROUND KT AT A BEND AND ALWAYS
CLAD STEEL ROD
EXOTHERMIC WELD
DIRECT GROUND WORE DOWN TO GROUND BAR.
WITH MINIMUM
5/8'0 X 8'-0' LONG
CO2 AWG BARE TINNED
CONNECTION (TYPEGT)
SOLID COPPER WIRE (UNIT
BOND)
2 BE TYPE AND PART NUMBER AS
KIT MMENDED
POD
012' %2 AWG SOD ONED BARE
OR RECONDING
SU BY CABLE MANUFACTERER.
COPPER WIRE EXOTHERMIC
PARALLEL EXOTHERMIC WELD
NOTES:
WELD CONNECTION TO
TO EXTERIOR GROUND RING
3. WEATHER PROOONG SHALL BE (TYPE AND PART NUMBER AS
1. GROUND LINE TO BE A MIN. OF 30. OR BELOW FROST UNE,
GROUND WELD'
SUPPLIED OR RECOMMENDED BY CABLE IMNUFACTERER.)
WHICHEVER DEEPER'
5/8' DLA. X 8' LONG
2. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED
GROUND ROD CRon CPPERDCUD0 ND
CABINET
CONNECTION OF GROUND
45 DECREES FROM THE VERTICAL
WITH ACCESS AREA CONNECTION (TYPE -Pr)
GROUNDING DETAIL
KIT TO ANTENNA CABLE
GROUND ROD
�1
G
D
SH16 NOT TO SCALE
SH16 NOT TO SCALE
SH1 NOT TO SCALE
H 1 6 NOT TO SCALE
�NwWBr
s
/_1
1,,;&TT
ABI/aeDW F k IWIWBIWWO
12975 Woddgate Drive
Herndon, VA. 20170
Notice:
mit dooumem mnbira r4mpary pop S,y inlpma"on
It may not no, reproduced. or ffororao,n ore in
tYSWUE Mthout wAXen anoont of ITT Carp, AES,
HAZELTINE/ITTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAWN BY. PP
ATC 30B NO.: 81388
CAGE CODE 9M715
DRAMNGNUMBER: SIZE: REV:
433961 K3 D 0
SCALE
WENT 16 a 18 NONE
J
NO
Li
O
0
U
z
O
Q
ry
J
0
LL1
J
U)
Z
/_1
1,,;&TT
ABI/aeDW F k IWIWBIWWO
12975 Woddgate Drive
Herndon, VA. 20170
Notice:
mit dooumem mnbira r4mpary pop S,y inlpma"on
It may not no, reproduced. or ffororao,n ore in
tYSWUE Mthout wAXen anoont of ITT Carp, AES,
HAZELTINE/ITTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAWN BY. PP
ATC 30B NO.: 81388
CAGE CODE 9M715
DRAMNGNUMBER: SIZE: REV:
433961 K3 D 0
SCALE
WENT 16 a 18 NONE
JUMPER, /2 SOLID,
BARE, TINNED COPPER
GROUNDING CONDUCTOR
TYPICAL GROUNDING
CONNECTION
SH17 NOT TO SCALE
bn1F9Ia#HDXii4:1
U.L APPROVED 20' X 1D0' PAVED ACCESS DRIVE
GROUNDING CLAMP, EXISTING CHAINLINK
TYPICAL AT EACH
CONDOR. FENCE W/3 -STRAND
BARBED WIRE
RE TINNED \
1ER WIRE
GROUND (1) PARKING
SPACE
PARALLEL TYPE
EXOTHERMIC WELD
TO GROUND RING
EXTERIOR GROUND
RING
TYPICAL MULTIPLE
e CONDUITS GROUNDING
SH17 NOT TO SCALE
NOTE:
CONTRACTOR TO USE KOPR-SHIELD,
PENETROX TYPE +E+ AT THESE CONNECTIONS
HEAT SHRINK ALL OUTSIDE LUG CONNECTIONS
NEW COAXIAL GROUND KITS W/ LONG BARREL
ALWAYS PROVIDE ONE SPACE / COMPRESSION LUGS (2 HOLES) TO BE INSTALLED
BETWEEN GROUNDING LUGS. E BY ANTENNA CONTRACTOR WITH HEAT SHRINK
TO GROUND KIT —� \ II n /-NEW 4' X 24' X 1/4' THK COPPER GROUND BAR
P
6RAVEL
SURFACE
r
EXISTING TOWER
GROUNDING
PROPOSED RT
GROUNDING
PROPOSED ITT
10' X 13'
EQUIPMENT 10'PAD j
WITHIN
10' X 15'
LEASE AREA
PROPOSED TIT
H -FRAME
R
PROPOSED CLEARIWRE
7' X 7' GROUND SPACE
EXISTING
LESSEE/USER
14' X 16'
SHELTER
ERMIC WELD
OWELD OR
PROPOSED ITT GPS (2)
LENT) PARALLEL,
EXTERIOR
(90') WELDS
GROUND RING, /2ED.
ATTACHED TO TME ICE'S r
Two PLACES \d
BRIDGE
SOLID, BARE, TINNEDG
LJ.
COPPER GROUNDINGDEFORMITIES
OR
CONDUCTOR
ALLOWED
F
0 0 O 0 0 000 000
O O O 0 0 0 0 0 0 0 0 0 0 0 0 0 O
0 TYPE HS CADWELD
MINIMUM
RADIUS 45
JUMPER, /2 SOLID,
BARE, TINNED COPPER
GROUNDING CONDUCTOR
TYPICAL GROUNDING
CONNECTION
SH17 NOT TO SCALE
bn1F9Ia#HDXii4:1
U.L APPROVED 20' X 1D0' PAVED ACCESS DRIVE
GROUNDING CLAMP, EXISTING CHAINLINK
TYPICAL AT EACH
CONDOR. FENCE W/3 -STRAND
BARBED WIRE
RE TINNED \
1ER WIRE
GROUND (1) PARKING
SPACE
PARALLEL TYPE
EXOTHERMIC WELD
TO GROUND RING
EXTERIOR GROUND
RING
TYPICAL MULTIPLE
e CONDUITS GROUNDING
SH17 NOT TO SCALE
NOTE:
CONTRACTOR TO USE KOPR-SHIELD,
PENETROX TYPE +E+ AT THESE CONNECTIONS
HEAT SHRINK ALL OUTSIDE LUG CONNECTIONS
NEW COAXIAL GROUND KITS W/ LONG BARREL
ALWAYS PROVIDE ONE SPACE / COMPRESSION LUGS (2 HOLES) TO BE INSTALLED
BETWEEN GROUNDING LUGS. E BY ANTENNA CONTRACTOR WITH HEAT SHRINK
TO GROUND KIT —� \ II n /-NEW 4' X 24' X 1/4' THK COPPER GROUND BAR
P
6RAVEL
SURFACE
r
EXISTING TOWER
GROUNDING
PROPOSED RT
GROUNDING
PROPOSED ITT
10' X 13'
EQUIPMENT 10'PAD j
WITHIN
10' X 15'
LEASE AREA
PROPOSED TIT
H -FRAME
R
PROPOSED CLEARIWRE
7' X 7' GROUND SPACE
EXISTING
LESSEE/USER
14' X 16'
SHELTER
NOTES:
1. ALL HARDWARE 6-88 STAINLESS STEEL INCLUDING BELLVILLES
COAT MATING SURFACES WITH KOPR-SHIELD BEFORE ATTACHMENT.
2. FOR GROUND BOND TO STEEL ONLY: INSERT A TOOTH WASHER
BETWEEN LUG AND STEEL, COAT ALL SURFACES WITH KOPR-SHIELE
3. ALL HOLES ARE COUNTERSUNK 1/16
4. ALL LUGS ARE DOUBLE HOLED 5. HEAT SHRINK ALL OUTSIDE
LUG CONNECTIONS
5. NO BACK TO HACK LUGS.
6. NO OVERLAPPING WASHER,
GROUND BAR DETAIL
NOT TO SCALE
PROPOSED RT
POWER ROUTING
—PROPOSED DT
TELCO ROUTING
LATTICE
TOWER
r\ e
a
.A
J
PROPOSED ITT GPS (2)
00 00 O D O 00 O O 00 O 000 O O
ATTACHED TO TME ICE'S r
Two PLACES \d
BRIDGE
4
LJ.
0000 O C O O O O 000 00000
000 0
SEAL AT
BI1LDNn WALLS
U
E' MINIMUM SEPARATION
0 0 O 0 0 000 000
O O O 0 0 0 0 0 0 0 0 0 0 0 0 0 O
0 TYPE HS CADWELD
O+ y+ \
1112 SOLID TINNED CU LEAD
TO EXTERIOR LOOP IN 1/2+
SEAL TRE W/ SILICON SEAL
0
24 -
U z
VERIFY IN FIELD
0
NOTES:
1. ALL HARDWARE 6-88 STAINLESS STEEL INCLUDING BELLVILLES
COAT MATING SURFACES WITH KOPR-SHIELD BEFORE ATTACHMENT.
2. FOR GROUND BOND TO STEEL ONLY: INSERT A TOOTH WASHER
BETWEEN LUG AND STEEL, COAT ALL SURFACES WITH KOPR-SHIELE
3. ALL HOLES ARE COUNTERSUNK 1/16
4. ALL LUGS ARE DOUBLE HOLED 5. HEAT SHRINK ALL OUTSIDE
LUG CONNECTIONS
5. NO BACK TO HACK LUGS.
6. NO OVERLAPPING WASHER,
GROUND BAR DETAIL
NOT TO SCALE
PROPOSED RT
POWER ROUTING
—PROPOSED DT
TELCO ROUTING
LATTICE
TOWER
r\ e
a
.A
�X / \
/ e
�lb
'S'J i5 PROPOSED ITT
'S5 GAS UNE ROUTING
PROPOSED RT
CE BRIDGE
PROPOSED ITT
LP GAS GENERATOR
PROPOSED ITT NEMA
3R 18' X 12' X 6' BOX
PROPOSED RT
CABINET
D COMPOUND GROUNDING PLAN
SH17 NOT TO SCALE
Ucense
ITT
Alrrwl `/1 - & falRwoM
12975 Woddgate Drive
Hemdon, VA. 20170
Notice:
It fray not rmrtrociu or
m
It may not in repmrnen lof I a Coro
Are S
eiacwseo w:nwu: wrinen cwsem of irr core. nes.
HAZE LTI N E/ITTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAWN By. PP o Op
ATC JOB NO.: 81 388
CAGECODE 9M715
DRAWING NUMBER: Bill: REV:
433961K3 D 2
SCALE.
.17m 18 NONE
J
0�/
LJ.
0
U z
0
C)
PROPOSED ITT
W
J
3'-6' X 3'-6'
PRO
_
�'—
CONCRETE PAD
FOR 120 GALLON
I her
- cl-
Specificati
PROPANE TANK
repo
_
�... finder lnV
/'- 10' NO SPARK
SUI`Cr
1:`_D6Y
BUFFER
PIC,
s of
EO ffi
_,.,-.3RlE
120 GA
120 GAL
\ PROPANE WiKt
�X / \
/ e
�lb
'S'J i5 PROPOSED ITT
'S5 GAS UNE ROUTING
PROPOSED RT
CE BRIDGE
PROPOSED ITT
LP GAS GENERATOR
PROPOSED ITT NEMA
3R 18' X 12' X 6' BOX
PROPOSED RT
CABINET
D COMPOUND GROUNDING PLAN
SH17 NOT TO SCALE
Ucense
ITT
Alrrwl `/1 - & falRwoM
12975 Woddgate Drive
Hemdon, VA. 20170
Notice:
It fray not rmrtrociu or
m
It may not in repmrnen lof I a Coro
Are S
eiacwseo w:nwu: wrinen cwsem of irr core. nes.
HAZE LTI N E/ITTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
DRAWN By. PP o Op
ATC JOB NO.: 81 388
CAGECODE 9M715
DRAWING NUMBER: Bill: REV:
433961K3 D 2
SCALE.
.17m 18 NONE
NOIFS
1. USE THIS SHEET N CMUNCTIDN CORN SHEET 14 (RISER DIAGRAM).
2. ALL UPOSED UNISTRUT S TO BE COLD SAWN AND RUBBER CAPPED.
3. ZINC PLATED HARDWARE IS NOT ACCEPTABLE.
4. All ELECTRICAL CABINETS, CONDUITS, ETC. TO BE SEALED WATER TIGHT.
GALVANIZED PIPE CAP
M' GALVANIZED PPE m
PROVIDE 3/16' THC CAP PIATE.
SEAL WELD AROUND
1 5/7' SOME P1DDO UIRSTRUT,
PROVIDE END CMS, FASTEN TO POST
WITH 11/2' STAINLESS U -BOLTS,
LOCATION TO SLAT UTILITY EO1P1@1T
ATTACHMENT REOUIREEIRS m
END CAP
m
N PVC CONDUIT (TYP.)
2' RNC BELOW FINISH GRADE AND
GRC ABOVE FN91 GRADE (IMP. 4)
TOP OF GRAVEL
FINISHED GRADE
FIBER CLOTH
RNC FROM TELCO DOM
RNC TELCO TO EQUIP.
/2 AMC GROUND WIRE
/2 AWG TWO CONDUCTOR TO GRNMD FIND (IMP.)
III -I
CONCRETE CAISSON (3000 PSI WN) I.
unsnnm SOIL
COORDINATE DISTANCE IN FIELD
24' X 24' X IV NOM 3R TELCO W OC V
BOX INCLUDE GI 41DBAR
ITH
(WITH PKI2GrA GND ROT))
GFCI WITH WEATHER
OUTDOOR RATED HALOGEN UDHT (REGENT PROOF COVER
PART NUMBER GP100WL OR EOUN.) n
TELCO
S
0
ATS
A H -FRAME ELEVATION
SHT8 NOT TO SCALE
NOTE: H—FRAME IS TO BE LOCATED A MINIMUM
OF 6" OFF OF CONCRETE SLAB.
100A SERVICE ENTRANCE RATED.
2 -POLE, REIN -311 120/240 V. ATS A
(AUIONATIC TRANSFER MICE) NEIN 3R PANEL BOND VIE our
DENERAC RTS OR EDUN. IOA INN CIRCUIT BREAKER fDB Y_
I, (MODEL OO1612MI25FTRB1OO
—�E WITH PKI2GTA OND KR)
SRR OP AM CAP Pr;
SPARE 1'
14 GROUND ELECTRIC CONDUCTOR N
1/2' RNC TD (2) 5/8-W GROUND
RODS PER NEC E BOOM TO GROUND RING.
License 4 44
W Enpn r ITT
life
Admn"d M!8&141 aWW
12975 Woddgate Drive
Herndon, VA. 20170
Notice:
i down l wnmins mTaa^r amria:a� ir:o�-,a1c
11 may not � repmduR . or Informalio, here r
Oisdosetl wilMN wMten mnsenldlTT Cor:
HAZELTIN E/ITTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
L'nis�31 PP
ATC JOB NO.: 81388
CAGE CODE 91M715
J
SIZE:
REV:
433961K3
O�/
0
I
SCALE'.
Ll_
NONE
Z
O
omom
U z
MPP
p 3:
omom
D-40
J
o m
oomom
I
QJ
m m
m m m
6'-0'
MAX !R—C
I�'--J specificat
m m
I
iC/)._ Under mY
1' RNC BFLOM FINISH GRADE AND�
cp
sll';
Z `.:CODS
GRC ABOVE FINISH GRADE (TYP. 3)
r•,
SRR OP AM CAP Pr;
SPARE 1'
14 GROUND ELECTRIC CONDUCTOR N
1/2' RNC TD (2) 5/8-W GROUND
RODS PER NEC E BOOM TO GROUND RING.
License 4 44
W Enpn r ITT
life
Admn"d M!8&141 aWW
12975 Woddgate Drive
Herndon, VA. 20170
Notice:
i down l wnmins mTaa^r amria:a� ir:o�-,a1c
11 may not � repmduR . or Informalio, here r
Oisdosetl wilMN wMten mnsenldlTT Cor:
HAZELTIN E/ITTSV 173-21
2290 LYMAN RD
HAZELTINE, MN 55317
L'nis�31 PP
ATC JOB NO.: 81388
CAGE CODE 91M715
or
DRAWINGNUMBER:
SIZE:
REV:
433961K3
ID
0
I
SCALE'.
sm 18 a 18
NONE
or
Generous, Bob
From:
Tim Jeske [TJeske@TCWR.NET]
Sent:
Monday, November 16, 2009 10:28 AM
To:
Generous, Bob
Cc:
Bob Suko; Mark Wegner
Subject:
Planning Case 09-19
Robert,
I am writing you in response to your notice pertaining to your planning case # 09-19 / PID: 25-8110240 for additional radio
equipment to be added to an existing tower situated close to TCWR property by Lyman Boulevard.
While we don't object to the structural element of this project we do have concerns pertaining to potential radio
interference. We use radio communications to control train and maintenance traffic on TCWR and interference with these
radio communications will cause operational and safety issues.
If TCWR gets assurance that this project will not interfere with our current radio system or any future communication
needs we would have no objections to this project.
Tim Jeske
Twin Cites & Western Railroad
Memorandum
TO: Bob Generous, Senior Planner
FROM: Terry Jeffery, Water Resources Coordinator
DATE: November 13, 2009
RE: Planning Case 09-19: American Tower CUP
I have reviewed the plans dated October 23, 2009 submitted by ITT Corporation for
the proposed improvements to the existing radio tower. Based upon my review, it
appears that no significant additional land disturbance will occur. As such, I have no
comments at this time.
I f you have any questions, please contact me at extension 1168.
Generous, Bob
From:
Fauske, Alyson
Sent:
Wednesday, November 18, 2009 2:44 PM
To:
Generous, Bob
Cc:
Oehme, Paul; Jeffery, Terry
Subject:
American Tower CUP Amendment
:..
The plans submitted show proposed improvements within the existing pad located north of Lyman Boulevard between
Galpin Boulevard and the railroad tracks. The applicant does not propose to expand the existing impervious surface.
There is no grading proposed. Engineering does not have any comments or conditions of approval.
Thanks,
Alyson Fauske
Assistant City Engineer
City of Chanhassen
ph: 952-227-1164
CITY OF CHANHASSEN
CARVER & HENNEPIN COUNTIES
NOTICE OF PUBLIC HEARING
PLANNING CASE NO. 09-19
NOTICE IS HEREBY GIVEN that the Chanhassen Planning Commission will hold a
public hearing on Tuesday, December 1, 2009, at 7:00 p.m. in the Council Chambers in
Chanhassen City Hall, 7700 Market Blvd. The purpose of this hearing is to consider a request for
an Amendment to Conditional Use Permit 90-3 to allow co-location/addition of 1TT/FAA antennas
and radio equipment at an existing telecommunication tower on property zoned Agricultural Estate
District A2 and located at 2290 Lyman Boulevard (Outlot B, Stone Creek First Addition).
Applicant: American Tower Company
A plan showing the location of the proposal is available for public review on the City's web
site at www.ci.chanhassen.mn.us/sere/olan/09-19.htm1 or at City Hall during regular business
hours. All interested persons are invited to attend this public hearing and express their opinions
with respect to this proposal.
Robert Generous, Senior Planner
Email: bQenerous@ci.chanhassen.mn.us
Phone: 952-227-1131
(Publish in the Chanhassen Villager on November 19, 2009)
SCANNED
MEMORANDUM
TO: Robert Generous, Senior Planner
FROM: Jerrin Mohn, Building Official
DATE: November 4, 2009
SUBJ: Site Plan Review for: Amendment to conditional use permit 90-3 at
existing telecommunication tower site at 2290 Lyman Blvd. to allow
co -location of equipment.
Planning Case: 09-19
I have reviewed the request for the above project and have the following conditions:
1. A building permit is required for equipment pad and LP gas storage tank pad.
2. A mechanical permit is required for connection (gas piping) of LP storage tank
to LP gas generator.
3. The plans must be signed by appropriate design professionals.
G:\PLAN\2009 Planning Cases\09-19 American Tower CUP 90-3 Amendment\buildingofficialcomments.doc
Date: November 2, 2009
City of Chanhassen
7700 Market Boulevard
P.O. Box 147
Chanhassen, MN 55317
(952) 227-1100
To: Development Plan Referral Agencies
From: Planning Department
Review Response Deadline: November 20, 2009
By: Robert Generous, Senior Planner
Subject: Request for Amendment to Conditional Use Permit 90-3 to allow co-location/addition of TIT/FAA
antennas and radio equipment at an existing telecommunication tower on property zoned Agricultural
Estate District A2 and located at 2290 Lyman Blvd. (Outlot B, Stone Creek Fust Addition)
Applicant: American Tower Company
Planning Case: 09-19 PID: 25-8110240
The above described application for approval of a land development proposal was filed with the Chanhassen Planning
Department on October 30, 2009. The 60 -day review period ends December 29, 2009.
In order for us to provide a complete analysis of issues for Planning Commission and City Council review, we would
appreciate your comments and recommendations concerning the impact of this proposal on traffic circulation, existing and
Proposed future utility services, storm water drainage, and the need for acquiring public lands or easements for park sites,
street extensions or improvements, and utilities. Where specific needs or problems exist, we would like to have a written
report to this effect from the agency concerned so that we can make a recommendation to the Planning Commission and City
Council.
This application is scheduled for consideration by the Chanhassen Planning Commission on December 1, 2009 at 7:00 p.m
in the Council Chambers at Chanhassen City Hall. We would appreciate receiving your comments by no later than
November 20, 2009. You may also appear at the Planning Commission meeting if you so desire. Your cooperation and
assistance is greatly appreciated.
1. City Departments:
a. City Engineer
b. City Attorney
c. City Park Director
d. Fire Marshal
e. Building Official
L Water Resources Coordinator
g. Forester
2. Carver Soil & Water Conservation District
3. MN Dept. of Transportation
4. MN Dept. of Natural Resources
5. U.S. Army Corps of Engineers
6. U.S. Fish & Wildlife
7. Carver County
a. Engineer
b. Environmental Services
8. Watershed District Engineer
a. Riley -Purgatory -Bluff Creek
b. Lower Minnesota River
c. Minnehaha Creek
9. Telephone Company (Qwest or Sprint/United)
10. Electric Company (Xcel Energy or MN Valley)
11. Mediacom
12. CenterPoint Energy Minnegasco
13. Twin Cities & Western Railroad
Legend
carver Raids
usxp.ae
YY Xew.ery
CakX Aotle
caanp Auh
./ rsen,ee Acos
/�,/• Cogan
h, as Rose
Likes
Pamela
cdor 2008
Map Created: 11-2-2009
PID# 258110240
(Parcellnjornradon
Property Address:
TaWyer lalormation:
NOT ON FILE
MERLE & JANE VOLK
C/O VERIZON WIRELESS
180 WASHINGTON VALLEY RD
ATTN: NETWORK REAL ESTATE
BEDMINSTER, NJ 07921
Parcel Properdes
GIS Acres: 3.32207475
Homestead: N
School District: 0112
Parcel Locadon
Section: IS
PI -t ormatlen:
Township: 116
STONE CREEK FIRST ADDITION
Range: 023
OUH.OT B
ayable Year 2010
jLa& Sale InjorMadon
Est Market Value Land: $246900Last
Sale NOT ON FILE
Est Market Value Building: $50200
Est Market Value Total: $297100
CARVER COUNTY GIS DISCLAEHER: This map was created using Carver County�s Geographic Information Systems (GIS), it is a compilation
of information and data from various Ciry, County State, and Federal otHces. This map is not a surveyed or legally recorded map and is intended to be
used as a reference. Carver County is not responsible for any inaccuracies contained herein.
PLEASE PRINT
Planning Case No. Dcl " i ni
CITY OF CHANHASSEN
7700 Market Boulevard — P.O. Box 147
Chanhassen, MN 55317 — (952) 227-1100
DEVELOPMENT REVIEW APPLICATION
Applicant Name and Address:
Doug Ruwe - American Tower
21307 Rio Oro Dr
C'ornelinc Nr 980 1
Contact:
Phone:704-975-6161 Fax:
Email: ougg ruwe@am@americantower.com
owner Name and Addre
Merle & Jane Volk
16925 County RD 40
Phone:
Email:
CITY OF CHANHASSEN
RECEIVED
OCT 3 0 2009
CHANHASSEN P1.NMNG DEPT
NOTE: Consultation with City staff is required prior to submittal, including review of development
plans
Comprehensive Plan Amendment_/
X Conditional Use Permit (CUP) 7iS�
Interim Use Permit (IUP)
Non -conforming Use Permit
_ Planned Unit Development*
_ Rezoning
Sign Permits
Sign Plan Review
Site Plan Review (SPR)*
Subdivision*
Temporary Sales Permit
Vacation of Right-of-Way/Easements (VAC)
Variance (VAR)
Wetland Alteration Permit (WAP)
Zoning Appeal
Zoning Ordinance Amendment
Notification Sign $200
(City to install and re ove)
X EscFiling Fees/Attorney Cost -
5
0 CUP SPRA/AC/VAR/WAP/Metes & Bounds
-$4
in(
SUB
TOTALFEE$ to-7CS—,ca CV- a',1r176v 1
An additional fee of $3.00 per address within the public hearing notification area will be invoiced to the applicant
prior to the public hearing.
*Sixteen (16) full-size folded copies of the plans must be submitted, including an 81/:" X 11"
reduced copy for each plan sheet along with a digital copy in TIFF -Group 4 (*.tif) format.
**Escrow will be required for other applications through the development contract.
Building material samples must be submitted with site plan reviews.
NOTE: When multiple applications are processed, the appropriate fee shall be charged for
each application.
PROJECTNAME: I7TSV173-21 Colocation
2290 L v
LOCATION: yman_ Chanhassen, MN 55317
LEGAL DESCRIPTION AND PID: -94-3243J-12. CA5 -$ 11 Omsk)
TOTAL ACREAGE:
WETLANDS PRESENT: YES X NO
PRESENTZONING: Commercial
REQUESTED ZONING: Commercial - amend COP 90-3
PRESENT LAND USE DESIGNATION:
REQUESTED LAND USE DESIGNATION:
REASON FOR REQUEST: To allow the colocation/addition of ITT/FAA antennas
and radio equipment at an existing telecommunication tower.
FOR SrrE PLAN REVIEW: Include number of ebsting employees:
and new employees:
This application must be completed in full and be typewritten or dearly printed and must be accompanied by all information
and plans required by applicable City Ordinance provisions. Before filing this application, you should confer with the
Planning Department to determine the specific ordinance and procedural requirements applicable to your application.
A determination of completeness of the application shall be made within 15 business days of application submittal. A written
notice of application deficiencies shall be mailed to the applicant within 15 business days of application.
This is to certify that I am making application for the described action by the City and that I am responsible for complying with
all City requirements with regard to this request. This application should be processed in my name and I am the party whom
the City should contact regarding any matter pertaining to this application. I have attached a copy of proof of ownership
(either copy of Owners Duplicate Certificate of Title, Abstract of Title or purchase agreement), or I am the authorized person
to make this application and the fee owner has also signed this application.
I will keep myself informed of the deadlines for submission of material and the progress of this application. I further
understand that additional fees may be charged for consulting fees, feasibility studies, etc. with an estimate prior to any
authorization to proceed with the study. The documents and information I have submitted are true and correct to the best of
my knowledge.
nature of Applicant Date
Signature of Fee Owner Date
G:1pl21111forms0evelopment Review Application.DOC Rev. 1/08
A
AMERICAN TOWER•
CO Nro AAT ICN
October 29, 2009
City of Chanhassen
Community Development — Bob Generous
7700 Market Boulevard, PO Box 147
Chanhassen, MN 55317
RE: ITTSV 173-07 ITT FAA Collocation
American Tower Site Code: 305556
2922 Hibbard Rd
Parcel Number 11-04-200-003
Dear Bob:
CITE DF CHANHASSEN
RECEIVED
OCT 3 0 2009
CHANHASSEN pLANNING DEPT
As we discussed, enclosed please find: City of Chanhassen Development Review Application to amend CUP90-3,
(2) letter of authorization (ITT/FAA), copy a stamped construction drawings for ITTSV 173-21, a stamped structural
analyses, and a check for $675.00 for the review fee for the zoning your review. Hopefully we can still make the
December meeting agendas.
Specifically, ITT is applying for zoning and building permits to collocate six (6) antennas and coaxial lines on the
existing tower referenced above. They will also be installing a radio equipment cabinet, an emergency back-up
diesel generator on a new concrete pad within the existing fenced compound. The tower will not increase in height
and the compound will not increase in size due to the installation. The purpose of this collocation is the replacement
of the existing FAA air navigation system. Once implemented, this new technology will greatly enhance the safety
of the traveling public in all types of aircraft. The total job cost is expected to be $30,000.00.
At this time American Tower has not selected a contractor, but once the use has been approved and the fees
determined, we will have the general contractor complete the building permit applications and pay any outstanding
fees. Please let me know if the material provided is deficient, or if you need any additional information. Should you
have any questions please contact me at (704) 975-6161 or by e-mail doug.ruwe@americantower.com.
American Tower greatly appreciates your assistance with this permit request.
Sincerely,
Doug Rowe
Project Manager Site Development
(704)975-6161
doug.ruwe@AmericanTower.com
Enclosures
21307 Rio Oro Dr • Comelius NC 28031 • (704) 9756161 • doug.ruwe@amerimntower.com
ITT
PERMIT AUTHORIZATION
Advanced Engineering & Sciences
12975 Wwklgen Drive
Herndon, VA 20170
I hereby authorize American Tower Corporation to act as agent for ITT Corporation, Advanced
Engineering & Sciences Division in the application for all permits and utility services associated with
this site.
ITT Corporation
Advanced Engineering & Sciences Division
An Indiana Corporation
j;
y: Frank Pallante
Title: Vice President of Contracts
Date: , - d?
COMMONWEALTH OF VIRGINIA
COUNTY OF FAIRFAX
The foregoing document was acknowledged before me this 1 ;2- day of kav , 2009 by
FCvsaf= ?Ca tloA-t_ , who is personally known to me.
1.ur'wwuYor- L-0 -If -
t;anrnonweYNVStetB o[ Via
TM "ft Wkwowvanabowlillim
bdmrmthis +Z1gya_�_
204& by, n
'"' MM"4 ion "PW": 19.qaust31, .ter z
W WUA"WJ1.WU
IQf 71007
v,ysyw.y •.+vr �•�.-<,e,nox..v,ga.e. .,•+:tw,.w
U.& Deporhnent
of Trorupwto"on
r9tlwat Aviatton
AdMnWatton
JAN - 2 2008
Mr. Greg Hughes
Contracts Manager. ADS -B Programs
ITT Corporation
Defense Electronics & Services
12975 Woridgate Drive
Herndon, VA 20170-6008
Re: Automatic Dependent Surveillance -Broadcast (ADS -B)
Contract DTFAWA-07-C-00067
Dear Mr. Hughes:
This letter serves to emphasize to you and your potential partners the importance of the
Federal Aviation Administration (FAA) ADS -B contract which was awarded to ITT
Corporation on August 30, 2007,
The FAA is undertaking a dramatic modernization of the National Airspace System under a
program entitled Next Generation Air Traffic Management Systems (NextGcn). The ADS -
B program is the cornerstone of the NextGen. ADS -B will provide technology that in the
near term will enhance safety and in the longer term promise significant system capacity and
efficiency benefits essential to meeting forecasted increases in air traffic demand.
ADS -B is and will remain a high visibility program. Avionics manufacturers and aviation
organizations/companies are relying on the FAA to meet the ADS -B implementation
schedule. The FAA has began full scale development of the ADS -B system with the award
of the ITT contract and will begin nation wide deployment in the near term.
Any support that can be given to ITT in the development and fielding of ADS -B
infrastructure is strongly encouraged. The FAA considers this program an opportunity to
significantly benefit the nation's transportation infrastructure with new technology.
It is believed that just as in the introduction of the internet, there will be many spin-off
opportunities.
--Slficml ,
Riche L. Day
Vice President
En Route and Oceanic ServiZ
Date: November 2, 2009
City of Chanhassen
7700 Market Boulevard
P.O. Box 147
Chanhassen, MN 55317
(952) 227-1100
To: Development Plan Referral Agencies
From: Planning Department
Review Response Deadline: November 20, 2009
By: Robert Generous, Senior Planner
Subject: Request for Amendment to Conditional Use Permit 90-3 to allow co-location/addition of ITT/FAA
antennas and radio equipment at an existing telecommunication tower on property zoned Agricultural
Estate District A2 and located at 2290 Lyman Blvd. (Outlot B, Stone Creek First Addition)
Applicant: American Tower Company
Planning Case: 09-19 PID: 25-8110240
The above described application for approval of a land development proposal was filed with the Chanhassen Planning
Department on October 30, 2009. The 60 -day review period ends December 29, 2009.
In order for us to provide a complete analysis of issues for Planning Commission and City Council review, we would
appreciate your comments and recommendations concerning the impact of this proposal on traffic circulation, existing and
proposed future utility services, storm water drainage, and the need for acquiring public lands or easements for park sites,
street extensions or improvements, and utilities. Where specific needs or problems exist, we would like to have a written
report to this effect from the agency concemed so that we can make a recommendation to the Planning Commission and City
Council.
This application is scheduled for consideration by the Chanhassen Planning Commission on December 1, 2009 at 7:00 p.m.
in the Council Chambers at Chanhassen City Hall. We would appreciate receiving your comments by no later than
November 20, 2009. You may also appear at the Planning Commission meeting if you so desire. Your cooperation and
assistance is greatly appreciated.
1. City Departments:
a. City Engineer
b. City Attorney
c. City Park Director
d. Fire Marshal
e. Building Official
E Water Resources Coordinator
g. Forester
2. Carver Soil & Water Conservation District
3. MN Dept. of Transportation
4. MN Dept. of Natural Resources
5. U.S. Army Corps of Engineers
6. U.S. Fish & Wildlife
7. Carver County
a. Engineer
b. Environmental Services
8. Watershed District Engineer
a. Riley -Purgatory -Bluff Creek
b. Lower Minnesota River
c. Minnehaha Creek
9. Telephone Company (Qwest)
10. Electric Company (MN Valley)
11. Mediacom
12. CenterPoint Energy Minnegasco
13. Twin Cities & Western Railroad
SCANNED
Legend
Camr Roser
m0ae.
IN "Yga
N cm t.r
C."Reeis
�..// t..wwe
cpt.ee.
Lukes
Parcels
Cda 2008
Nap Created: 11-2-2009
�arcelInformation
Properly Address:
Taxpayer tnforrnstloa:
NOT ON FILE
MERLE & JANE VOLK
C/O VERIZON WIRELESS
ISO WASHINGTON VALLEY ED
ATM: NETWORK REAL ESTATE
BEDMINSTER, NJ 07921
Parcel Properties
GIS Acres: 3.32207475
Homestead: N
School District: 0112
Parcel Location
Section: 15
Plat Itafosaatlow
Township: 116
STONE CREEK FIRST ADDITION
Rage: 023
OUTLOT B
ayable Year 2010
Sale Information
Est Market Value Lad: $246900Loa
Sale NOT ON FILE
EIL Market Value Building- $50200
Est. Market Value Total: $297100
CARVER COUNTY GIS DISCLAIMER: This map was created using Carver County's Geographic Information Systems (GIS), it is a compilation AN I
of information and data from various City, County, State, and Federal offices. This map is not a surveyed or legally recorded map and is intended to be
used as a reference. Carver County is not responsible for any inaccuracies contained herein.
Date: November 2, 2009
City of Chanhassen
7700 Market Boulevard
P.O. Box 147
Chanhassen, MN 55317
(952) 227-1100
To: Development Pian Referral Agencies
From: Planning Department
Review Response Deadline: November 20, 2009
By: Robert Generous, Senior Planner
Subject: Request for Amendment to Conditional Use Permit 90-3 to allow co-location/addition of ITT/FAA
antennas and radio equipment at an existing telecommunication tower on property zoned Agricultural
Estate District A2 and located at 2290 Lyman Blvd. (Outlot B, Stone Creek Fust Addition)
Applicant: American Tower Company
Planning Case: 09-19 PID: 25-8110240
The above described application for approval of a land development proposal was filed with the Chanhassen Planning
Department on October 30, 2009. The 60 -day review period ends December 29, 2009.
In order for us to provide a complete analysis of issues for Planning Commission and City Council review, we would
appreciate your comments and recommendations concerning the impact of this proposal on traffic circulation, existing and
proposed future utility services, storm water drainage, and the need for acquiring public lands or easements for park sites,
street extensions or improvements, and utilities. Where specific needs or problems exist, we would like to have a written
report to this effect from the agency concerned so that we can make a recommendation to the Planning Commission and City
Council.
This application is scheduled for consideration by the Chanhassen Planning Commission on December 1, 2009 at 7:00 p.m.
in the Council Chambers at Chanhassen City Hall. We would appreciate receiving your comments by no later than
November 20, 2009. You may also appear at the Planning Commission meelmg if you so desire. Your cooperation and
assistance is greatly appreciated. `t _ JSo�s,-,'�� / 0r)
1. City Departments: I V 5 �Carver County
a. City Engineer a. Engineer
b. City Attorney b. Environmental Services
c. City Park Director
d. Fire Marshal
e. Building Official
f. Water Resources Coordinator
g. Forester
2. Carver Soil & Water Conservation District
3. MN Dept. of Transportation
4. MN Dept. of Natural Resources
5. U.S. Army Corps of Engineers
6. U.S. Fish & Wildlife
8. Watershed District Engineer
a. Riley -Purgatory -Bluff Creek
b. Lower Minnesota River
c. Minnehaha Creek
9. Telephone Company (Qwest or Sprint/United)
10. Electric Company (Xcel Energy or MN Valley)
11. Mediacom
12. CenterPoint Energy Minnegasco
13. Twin Cities & Western Railroad SCANNED
AMERICAN TOWER CUP 90-3 AMENDMENT - PLANNING CASE 09-19
$425 Conditional Use Permit
$50 Recording Fee
$200 Notification Sign
$675 TOTAL
$675 Less Check No. 238809 from ATC Tower Services, Inc.
SCANNED
CITY OF CHANHASSEN
P 0 BOX 147
CHANHASSEN MN 55317
10/30/2009 2:35 PM
Receipt No. 0113557
CLERK: katie
PAYEE: ATC Tower Services, Inc
-------------------------------------------------------
Use & Variance 425.00
Sign Rent 200.00
Recording Fees 50.00
Total
675.00
Cash
0.00
Check 238809
675.00
Change
0.00
SCANNED
T4able Year 2010
EsL Market Value Land: $246900
Eat Market Value Building: $50200
Map Created: 10-30.2009 Est Market Value Total: $297100
raryayer information:
MERLE & JANE VOLK
C(O VERIZON WIRELESS
180 WASHINGTON VALLEY RD
ATIN: NETWORK REAL ESTATE
BEDMINSTER, NJ 07921
ADDITION
t Sale Information
Sale NOT ON FILE
CARVER COUNTY GIS DISCLAIMER: This map was created using Carver County's Geographic Information Systems (GIS), it is a compilation
of information and data fiom various City, Cowry, State, and Federal offi=. This map is not a surveyed or legally recorded map and is intended to be
used as a reference. Carver County is not responsible for my inaccuracies contained hereia
SCANNED
Legend
areellnjormadon
Property Address:
Carrer8wds
NOT ON FILE
usq' p
�!
MAN.,
Ca,nry Awa
r nr A a
Parcel Properties
GIS Acres 3.32207475
HomeskW: N
/✓
^"s.AOm
School District: 0112
lakes
arcel Location
Pane,
Section: IS
Cdv 1911
Tov :s . 116
T4able Year 2010
EsL Market Value Land: $246900
Eat Market Value Building: $50200
Map Created: 10-30.2009 Est Market Value Total: $297100
raryayer information:
MERLE & JANE VOLK
C(O VERIZON WIRELESS
180 WASHINGTON VALLEY RD
ATIN: NETWORK REAL ESTATE
BEDMINSTER, NJ 07921
ADDITION
t Sale Information
Sale NOT ON FILE
CARVER COUNTY GIS DISCLAIMER: This map was created using Carver County's Geographic Information Systems (GIS), it is a compilation
of information and data fiom various City, Cowry, State, and Federal offi=. This map is not a surveyed or legally recorded map and is intended to be
used as a reference. Carver County is not responsible for my inaccuracies contained hereia
SCANNED
I'�M=RICAN TOW=R
Structural Analysis Report
Structure
ATC Site Name
ATC Site Number
Proposed Carrier
Carrier Site Name
Carrier Site Number
County
Engineering Number
Date
115 ft Pirod Self Supported Tower
Hazeltine, MN
81388
ITT Corporation
Chanhassen
173-21
Carver
43396122
June 3, 2009
Usage 40% Legs, 70% Diagonals,
9% Horizontals
Submitted by:
Christopher L. Jolly, E.I.
Design Engineer
American Tower Engineering Services
400 Regency Forest Drive
Cary, NC 27518
Phone: 919-468-0112
PROFESSIONAL ENGINEER
I hereby certify that this plan, specification, or
report was prepa*ed by me or under my direct
supervision and that 1 am a duly Licensed
Professional Enemeer under the laws of the
State of Mmn Qsota.
PnntName: RaphaelI Mohamed
Signature:
Dater Lw:nse 4 44557
SCANNED
Engineering Number 43396122
June 3, 2009
Page 1
Introduction
The purpose of this report is to summarize results of the structural analysis performed on the 115 ft
Pirod Self Supported Tower located at 2290 Lyman Blvd., Chanhassen, Minnesota, 55317, Carver
County (ATC Site No. 81388). The tower was originally designed and manufactured by Pirod
(Drawing No. 114515-B, dated August 15, 1990).
Analysis
The tower was analyzed using Semaan Engineering Solutions, Inc, Software. The analysis assumes that
the tower is in good, undamaged, and non -corroded condition.
Basic Wind Speed: 80 mph (Fastest Mile)
Radial lee: 69 mph (Fastest Mile) w/ %:" ice
Code: TIA/EIA-222-F / 2006 IBC Section 1609.1.1, Exception (4) and Section
3108.4 / 2007 Minnesota State Building Code
Antenna Loads
The following antenna loads were used in the tower analysis.
Existing Antennas
[lov.
Qty Antennas
Mount
Coax
Carrier
114.0
6 Swedcom ALP 9214-N
(3) Flat Light Sector Frames
6 7/8"
Verizon
6 Antel LPA-185080/8CF
6 1 5/8"
6 TTA
4 15/8"
3 CSS VC -880
3 7/8"
3 CSS DBC -750
Proposed Antennas
Eley.
01)Antennas
Qty
Mount
Coax
Carrier
95.0
1Vertex 101 V VPD
(3) Stand Off
1 7/8"
[TT Corporation
1 DBS stems 5100A
1 15/8"
4 DBS stems 5100A -D
4 15/8"
Install proposed coax on empty tower leg.
Engineering Number 43396122
June 3, 2009
Page 2
Results
The maximum structure usage is: 70%
Leg Forces
Original Design
Reactions
Current Analysis
Reactions
o
/o Of Design
Uplift Kis
223.9
91-041
Axial Kis
241.9
109.1
45
Shear Kis
40.6
15.9
39
The structure base reactions resulting from this analysis are acceptable when compared to the reactions
shown on the original structure drawings, therefore no modification or reinforcement of the foundation
will be required.
Conclusion
Based on the analysis resuhs, the structure meets the requirements per TIA/EIA-222-F and 2007
MSBC standards. The tower and foundation can support the existing and proposed antennas with the
TX line distribution as described in this report.
If you have any questions or require additional information, please call 919-465-6545.
Standard Conditions
All engineering services are performed on the basis that the information used is current and correct. This
information may consist of but is not necessary limited, to:
-- Information supplied by the client regarding the structure itself, the antenna and feed line loading
on the structure and its components, or other relevant information.
-- Information from drawings in the possession of American Tower Corporation, or generated by
field inspections or measurements of the structure.
It is the responsibility of the client to ensure that the information provided to ATC Engineering Services
and used in the performance of our engineering services is correct and complete. In the absence of
information to the contrary, we assume that all structures were constructed in accordance with the
drawings and specifications and are in an un -corroded condition and have not deteriorated; and we,
therefore, assume that their capacity has not significantly changed from the "as new" condition.
All services will be performed to the codes specified by the client, and we do not imply to meet any
other codes or requirements unless explicitly agreed in writing. If wind and ice loads or other relevant
parameters are to be different from the minimum values recommended by the codes, the client shall
specify the exact requirement. In the absence of information to the contrary, all work will be performed
in accordance with the latest relevant revision of ANSI/EIA-222.
All services are performed, results obtained, and recommendations made in accordance with generally
accepted engineering principles and practices. ATC Engineering Services is not responsible for the
conclusions, opinions and recommendations made by others based on the information we supply.
Copyright Semaan Engineering Solutions, Inc
Loads: 80 mph no ice
69 moh wl 1/2" radial ice
Job Information
Tower: 81988 Location : Hazeltine, MN
Code: TIA/EIA-222 Rev F Shape : Triangle Base Width : 19.00 ft
Client: ITT Corporation Top Width: 7.50 ft
1 .2 128 501s1 12"BD 1.75" SAE 36ksi 4X4%0.25
3 12B 50ks1 12"BD 1.75" SAE 36ks1 3%3X0.3125
4.5 12B SOW 12"SO 1.5" SAE 36ksi 3X3%0.1875
6 12B 50ksl 12"BD 1.25" SAE 36ksi 2.5X2.5)(0.1875 SAE 36ksi 2.SX2.6X0.1a75
Discrete Appurtenance
Elev
(ft) TV pe Qty Description
114.00 3 CSS DSC -750
114.00 Panel 3 CSS X7C-890
114.00 6 TTA
114.00 Mountlna Frame 3 Flat Liaht Sector Frames
114.00 Panel 6 Antal LPA-165080/8CF
114.00 Panel 6 Swedcom ALP 9214-N
95.00 Whip 4 OB Systems 510OA-D
95.00 Whip 1 OB Systems 5100A
95.00 Stralaht Arm 3 Stand Off
95.00 Panel 1 Vertex 101V VPD
Linear Appurtenance
Elev (ft)
Uplift 90.97 k Moment 1.678.86 ft -k
Vert 109.08 k Total Down 20.69 k
Honz 15.86 k Total Shear 23.39 k
From To City Description
0.000 115.00 1 Climbing Ladder
0.000 114.00 9 719" Coax
0.000 114.00 6 1 519" Coax
Copyrght Senni Engineering Solutions, Inc
Site Number: 81388 Y 613120091:49:08 PM
Location: Hazeltine, MN
Code: TIA/EIA-222 Rev F X
Gh : 1.15 Section Forces
LoadCase Normal No Ice 80.00 mph Wind Normal To Face with No Ice
Allow Stress Inc: 1.333
Dead LF: 1.000
Wind LF: 1.000
LoadCase 60 deg No Ice 80.00 mph Wind at 60 deg From Face with No Ice
Allow Stress Inc: 1.333
Dead LF: 1.000
Wind LF: 1.000
Total
Total
Ice
Ice
Wind
Flat
Round
Round
Round
Eff
Linear
Linear
Total
Total
Struct
Linear Total
Linear
Sect Height
Area
Area
Area
Sal
Area
Area
Area
Area
Weight
Weight
Force
Force Force
Eff
Seq (ft) qz
(sqft)
(sqft)
(sqft)
Ratio
Cf Df Dr Rr
(sqft)
(sqft)
(sqft)
(Ib)
Ice (lb)
(Ib)
(lb) (Ib)
Face
6 102.5 22.65
12.37
19.53
0.00
0.15
2.791.00 1.00 0.58
23.71
54.21
0.00
2,676.9
0.0
1,724.19
1,697.2 3,421.47
1
5 80.00 21.10
14.44
17.23
0.00
0.14
2.791.00 1.00 0.58
24.45
59.47
0.00
2,789.4
0.0
1,660.13
1,734.6 3,394.74
1
4 60.00 19.44
15.97
17.23
0.00
0.13
2.861.00 1.00 0.58
25.93
59.47
0.00
2,857.7
0.0
1,657.74
1,597.7 3,255.47
1
3 40.00 17.31
17.56
18.83
0.00
0.12
2.881.00 1.00 0.58
28.44
59.47
0.00
3.825.9
0.0
1,633.06
1,422.9 3.056.02
1
2 20.00 16.38
25.68
18.83
0.00
0.13
2.841.00 1.00 0.58
36.57
59.47
0.00
4,068.3
0.0
1,962.56
1,346.8 3,309.42
1
1 5.00 16.38
13.71
9.42
0.00
0.12
2.871.00 1.00 0.58
19.15
29.73
0.00
2,085.8
0.0
1,035.75
673.43 1,709.18
1
2.87 0.85 1.00 0.58
17.09
29.73
0.00
2,085.8
0.0
924.54
673.43
1,597.97
18,303.9
0.0
18,146.30
LoadCase 60 deg No Ice 80.00 mph Wind at 60 deg From Face with No Ice
Allow Stress Inc: 1.333
Dead LF: 1.000
Wind LF: 1.000
LoadCase 90 deg No Ice 80.00 mph Wind at 90 deg From Face with No Ice
Allow Stress Inc: 1.333
Dead LF: 1.000
Wind LF: 1.000
Total
Total
Ice
Ice
Wind
Flat
Round
Round
Round
Eff
Linear
Linear
Total
Total
Struct
Linear Total
Linear
Sect Height
Area
Area
Area
Sol
Area
Area
Area
Area
Weight
Weight
Force
Force Force
Eff
Seq (ft) qz
(sqft)
(sqft)
(sqft)
Ratio
Cf Df Dr Rr
(sqft)
(sqft)
(sqft)
(I b)
Ice (lb)
(Ib)
(I b) (Ib)
Face
6 102.5 22.65
12.37
19.53
0.00
0.15
2.79 0.80 1.00 0.58
21.24
54.21
0.00
2,676.9
0.0
1,544.35
1,697.2 3,241.63
1
5 80.00 21.10
14.44
17.23
0.00
0.14
2.79 0.80 1.00 0.58
21.56
59.47
0.00
2,789.4
0.0
1,463.97
1,734.6 3,198.57
1
4 60.00 19.44
15.97
17.23
0.00
0.13
2.86 0.80 1.00 0.58
22.74
59.47
0.00
2,857.7
0.0
1,453.59
1,597.7 3,051.32
1
3 40.00 17.31
17.56
18.83
0.00
0.12
2.88 0.80 1.00 0.58
24.92
59.47
0.00
3,825.9
0.0
1,431.35
1,422.9 2,854.31
1
2 20.00 16.38
25.68
18.83
0.00
0.13
2.84 0.80 1.00 0.58
31.44
59.47
0.00
4,068.3
0.0
1,687.01
1,346.8 3,033.87
1
1 5.00 16.38
13.71
9.42
0.00
0.12
2.87 0.80 1.00 0.58
16.41
29.73
0.00
2,085.8
0.0
887.47
673.43 1,560.90
1
2.87 0.85 1.00 0.58
17.09
29.73
0.00
2,085.8
0.0
924.54
673.43
1,597.97
18,303.9
0.0
16,940.60
LoadCase 90 deg No Ice 80.00 mph Wind at 90 deg From Face with No Ice
Allow Stress Inc: 1.333
Dead LF: 1.000
Wind LF: 1.000
Page 1
Total
Total
Ice
Ice
Wind
Flat
Round
Round
Eff
Linear
Linear
Total
Struct
Linear
Total
Sect Height
Area
Area
Area
Sol
Area
Area
Area
Weight
Weight
Force
Force
Force
Eff
Seq (ft) qz
(sqft)
(sqft)
(sqft)
Ratio
Cf Df Dr Rr
(sqft)
(sqft)
(sqft)
(Ib)
Ice (lb)
(Ib)
(Ib)
(Ib)
Face
6 102.5 22.65
12.37
19.53
0.00
0.15
2.79 0.85 1.00 0.58
21.86
54.21
0.00
2,676.9
0.0
1,589.31
1,697.2
3,286.59
1
5 80.00 21.10
14.44
17.23
0.00
0.14
2.79 0.85 1.00 0.58
22.28
59.47
0.00
2,789.4
0.0
1,513.01
1,734.6
3,247.61
1
4 60.00 19.44
15.97
17.23
0.00
0.13
2.86 0.85 1.00 0.58
23.54
59.47
0.00
2,857.7
0.0
1,504.63
1,597.7
3,102.36
1
3 40.00 17.31
17.56
18.83
0.00
0.12
2.88 0.85 1.00 0.58
25.80
59.47
0.00
3,825.9
0.0
1,481.78
1,422.9
2,904.74
1
2 20.00 16.38
25.68
18.83
0.00
0.13
2.84 0.85 1.00 0.58
32.72
59.47
0.00
4,068.3
0.0
1,755.90
1,346.8
3,102.76
1
1 5.00 16.38
13.71
9.42
0.00
0.12
2.87 0.85 1.00 0.58
17.09
29.73
0.00
2,085.8
0.0
924.54
673.43
1,597.97
1
18,303.9
0.0
17,242.02
Page 1
Gh : 1.15
LoadCase Normal Ice
Allow Stress Inc: 1.333
Dead LF: 1.000
Wind LF: 1.000
Total Total Ice
Site Number: 81388
Location: Hazeltine, MN
Code: TIA/EIA-222 Rev F
Section Forces
69.28 mph Wind Normal To Face with Ice
Ice
Copyright Sennaan Engineering Solutions, Inc
Y 61312009 1:49:08 PM
X
Wind
Flat
Round
Round
Eff
Linear
Linear
Total
Struct
Linear Total
Sect Height
Area
Area
Area
Sol
Area
Area
Area
Weight
Weight
Force
Force Force
Eff
Seq (ft) qz
(sqft)
(sqft)
(sqft)
Ratio
Cf Df Dr Rr
(sqft)
(sqft)
(sqft)
(I b)
Ice (lb)
(Ib)
(Ib) (Ib)
Face
6 102.5 16.99
12.37
28.82
9.29
0.19
2.641.00 1.00 0.59
29.31
54.21
34.58
3,832.4
1,155.5
1,511.79
2,084.9 3,596.72
1
5 80.00 15.82
14.44
25.53
8.30
0.18
2.661.00 1.00 0.59
29.42
59.47
36.67
4,018.6
1,229.2
1,425.82
2,102.9 3,528.81
1
4 60.00 14.58
15.97
26.04
8.81
0.16
2.731.00 1.00 0.58
31.15
59.47
36.67
4,133.5
1,275.8
1,427.82
1,937.0 3.364.87
1
3 40.00 12.98
17.56
28.18
9.35
0.15
2.761.00 1.00 0.58
33.96
59.47
36.67
5,168.6
1,342.7
1,402.89
1,725.1 3,128.05
1
2 20.00 12.29
25.68
28.75
9.91
0.16
2.731.00 1.00 0.58
42.44
59.47
36.67
5,646.5
1,578.2
1,642.75
1,632.9 3,275.65
1
1 5.00 12.29
13.71
14.59
5.17
0.15
2.76 1.00 1.00 0.58
22.20
29.73
18.33
2,900.8
815.0
867.43
816.45 1,683.88
1
25,700.3 7,396.4 18,577.98
LoadCase 60 deg Ice 69.28 mph Wind at 60 deg From Face with Ice
Allow Stress Inc: 1,333
Dead LF: 1.000
Wind LF: 1.000
25,700.3 7,396.4 17,713.08
LoadCase 90 deg Ice 69.28 mph Wind at 90 deg From Face with Ice
Allow Stress Inc: 1.333
Dead LF: 1,000
Wind LF: 1.000
Total
Total
Ice
Ice
Wind
Flat
Round
Round
Round
Eff
Linear
Linear
Total
Total
Struct
Linear Total
Linear
Sect Height
Area
Area
Area
Sol
Area
Area
Area
Area
Weight
Weight
Force
Force Force
Eff
Seq (ft) qz
(sqft)
(sqft)
(sqft)
Ratio
Cf Df Dr Rr
(sqft)
(sqft)
(sqft)
(Ib)
Ice (lb)
(Ib)
(Ib) (Ib)
Face
6 102.5 16.99
12.37
28.82
9.29
0.19
2.64 0.80 1.00 0.59
26.84
54.21
34.58
3,832.4
1,155.5
1,384.24
2,084.9 3,469.17
1
5 80.00 15.82
14.44
25.53
8.30
0.18
2.660.80 1.00 0.59
26.53
59.47
36.67
4,018.6
1,229.2
1,285.84
2,102.9 3,388.83
1
4 60.00 14.58
15.97
26.04
8.81
0.16
2.73 0.80 1.00 0.58
27.96
59.47
36.67
4,133.5
1,275.8
1,281.47
1,937.0 3,218.52
1
3 40.00 12.98
17.56
28.18
9.35
0.15
2.76 0.80 1.00 0.58
30.45
59.47
36.67
5,168.6
1,342.7
1,257.79
1,725.1 2,982.95
1
2 20.00 12.29
25.68
28.75
9.91
0.16
2.73 0.80 1.00 0.58
37.30
59.47
36.67
5,646.5
1,578.2
1,443.96
1.632.9 3.076.86
1
1 5.00 12.29
13.71
14.59
5.17
0.15
2.76 0.80 1.00 0.58
19.46
29.73
18.33
2,900.8
815.0
760.30
816.45 1,576.75
1
25,700.3 7,396.4 17,713.08
LoadCase 90 deg Ice 69.28 mph Wind at 90 deg From Face with Ice
Allow Stress Inc: 1.333
Dead LF: 1,000
Wind LF: 1.000
25,700.3 7,396.4 17,929.31
Page 2
Total
Total
Ice
Ice
Wind
Flat
Round
Round
Eff
Linear
Linear
Total
Struct
Linear
Total
Sect Height
Area
Area
Area
Sol
Area
Area
Area
Weight
Weight
Force
Force
Force
Eff
Seq (ft) qz
(sqft)
(sqft)
(sqft)
Ratio
Cf Df Dr Rr
(sqft)
(sqft)
(sqft)
(Ib)
Ice (lb)
(Ib)
(1 b)
(Ib)
Face
6 102.5 16.99
12.37
28.82
9.29
0.19
2.64 0.85 1.00 0.59
27.46
54.21
34.58
3.832.4
1.155.5
1,416.12
2.084.9
3.501.06
1
5 80.00 15.82
14.44
25.53
8.30
0.18
2.66 0.85 1.00 0.59
27.26
59.47
36.67
4,018.6
1,229.2
1,320.83
2,102.9
3,423.82
1
4 60.00 14.58
15.97
26.04
8.81
0.16
2.73 0.85 1.00 0.58
28.76
59.47
36.67
4,133.5
1,275.8
1,318.06
1,937.0
3,255.11
1
3 40.00 12.98
17.56
28.18
9.35
0.15
2.76 0.85 1.00 0.58
31.33
59.47
36.67
5,168.6
1,342.7
1,294.06
1,725.1
3,019.22
1
2 20.00 12.29
25.68
28.75
9.91
0.16
2.73 0.85 1.00 0.58
38.59
59.47
36.67
5,646.5
1,578.2
1,493.66
1,632.9
3,126.56
1
1 5.00 12.29
13.71
14.59
5.17
0.15
2.76 0.85 1.00 0.58
20.14
29.73
18.33
2,900.8
815.0
787.08
816.45
1,603.53
1
25,700.3 7,396.4 17,929.31
Page 2
Site Number: 81388
Location: Hazeltine, MN
Code: TIA/EIA-222 Rev F
Tower Loading
Discrete Appurtenance Properties
Copyright Semaan Engineering Solutions, Inc
Y 61312009 1:49:08 PM
X
Z/
Attach
Elev
No Ice
Ice
Distance
To
Vert
Flev
Width
Weight
Weiqht
CaAa
CaAa
Weight
CaAa
CaAa
From Face
XAngle
Ecc
(ft)
Description
Qty
(Ib)
(sf)
Factor
(lb)
(sf)
Factor
(ft)
(deg)
(ft)
114.0
CSS DBC -750
3
4.88
0.510
0.67
7.65
0.650
0.67
0.000
0.00
0.000
114.0
CSS X7C-880
3
40.00
12.580
0.82
110.60
13.560
0.82
0.000
0.00
0.000
114.0
TTA
6
10.00
1.400
0.67
20.34
1.640
0.67
0.000
0.00
0.000
114.0
Flat Light Sector Frames
3
400.00
17.900
0.75
510.00
22.200
0.75
0.000
0.00
0.000
114.0
Antel LPA-18508018CF
6
7.00
2.095
1.17
25.04
2.400
1.17
0.000
0.00
0.000
114.0
Swedcom ALP 9214-N
6
53.00
11.890
1.04
151.00
12.860
1.04
0.000
0.00
0.000
95.00
DB Systems 5100A -D
4
38.00
3.090
1.00
66.00
3.500
1.00
0.000
0.00
3.240
95.00
DB Systems 5100A
1
21.00
2.070
1.00
36.30
2.460
1.00
0.000
0.00
3.240
95.00
Stand Off
3
150.00
6.300
0.67
230.00
7.000
0.67
0.000
0.00
0.000
95.00
Vertex 101V VPD
1
4.00
2.540
1.00
26.20
4.520
1.00
0.000
0.00
0.000
Totals 36 2381.64
Linear Appurtenance Properties
4079.51 Number of Appurtenances: 10
Elev
Elev
From
To
Width
Weight
Pct
Spread On
Bundling
(ft)
(ft)
Description
Qty
(in)
(Ib/ft)
In Wind
Faces
Arrangement
0.00
115.0
Climbinq Ladder
1
3.00
6.90
100.00
Lin App
Separate
0.00
114.0
1518" Coax
6
1.98
0.82
100.00
Lin App
Separate
0.00
114.0
718" Coax
9
1.09
0.33
100.00
Lin App
Separate
0.00
95.00
1 518" Coax
5
1.98
0.82
100.00
Lin App
Separate
0.00
95.00
718" Coax
1
1.09
0.33
100.00
Lin App
Separate
Page 3
Site Number: 81388
Location: Hazeltine, MN
Code: TIA/EIA-222 Rev F
ForcelfStress Summary
Copyright Semaan Engineering Solutions, Inc
1::12009 1:49:08 PM
ZXZ
Section: 1 1.75
Bot Elev (ft): 0.00 Height (ft):
10.000
Num
Shear Bear
Use
Max Tension Member
(kip) Load Case
(ksi) (kip) Bolts
Member
Cap(kip) Cap(kip)
Shear
Bear
LEG 12B - 12"BD 1.75'
Force
Len
Bracing %
Fa Cap Num
Num
Cap
Cap
Use
Max Compression Member
(kip) Load Case
(ft)
X Y Z KL/R
(ksi) (kip) Bolts
Holes
(kip)
(kip)
% Controls
LEG 12B-12"BD 1.75"
-103.98 Normal No Ice
10.02100
100 100 0.0
0.0 258.77 0
0
0.00
0.00
40 User Input
HORIZ
0.00
0.000
0 0 0 0.0
0.0 0.00 0
0
0.00
0.00
0
DIAG SAE-4X4X0.25
-5.07 90 deg No Ice
21.03
50 75 50 158.7
7.9 15.33 1
1
21.98
23.20
33 Member Z
Page 4
Force
Fy Cap Num
Num
Shear Bear
Use
Max Tension Member
(kip) Load Case
(ksi) (kip) Bolts
Holes
Cap(kip) Cap(kip)
Controls
LEG 12B - 12"BD 1.75'
87.14 60 deg No Ice
50 288.64 0
0
0.00 0.00
30
User Input
HORIZ
0.00
0 0.00 0
0
0.00 0.00
0
DIAG SAE - 4X4X0.25
6.64 90 deg Ice
36 48.55 1
1
21.98 23.20
30
Bolt Shear
Force
Capacity Use
Num
Max Splice Forces
(kip) Load Case
(kip) /
Bolts Bolt Type
Top Tension
83.10 60 deg No Ice
0.00 0
Top Compression
99.90 Normal No Ice
0.00 0
Bot Tension
91.88 60 deg No Ice
305.25 30
6 1 A687
Bot Compression
109.21 Normal No Ice
0.00 0
Section: 2 1.75
Bot Elev (ft): 10.00 Height (ft):
20.000
Member
Shear Bear
Force
Len Bracing %
Fa Cap Num Num
Cap Cap
Use
Max Compression Member
(kip) Load Case
(ft) X Y Z
KUR
(ksi) (kip) Bolts Holes
(kip) (kip)
% Controls
LEG 12B - 12"BD 1.75'
-95.42 Normal No Ice
10.02 100 100 100
0.0
0.0 258.77 0
0
0.00 0.00
36 User Input
HORIZ
0.00
0.000 0 0 0
0.0
0.0 0.00 0
0
0.00 0.00
0
DIAG SAE-4X4X0.25
-6.12 90 deg Ice
20.15 50 75 50
152.1
8.6 16.69 1
1
21.98 23.20
36 Member
Force
Fy Cap Num
Num
Shear Bear
Use
Max Tension Member
(kip) Load Case
(ksi) (kip) Bolts
Hales
Cap (kip) Cap(kip)
%
Controls
LEG 12B - 12"BD 1.75'
79.54 60 deg No Ice
50 288.64 0
0
0.00 0.00
27
User Input
HORIZ
0.00
0 0.00 0
0
0.00 0.00
0
DIAG SAE - 4X4X0.25
5.39 90 deg Ice
36 48.55 1
1
21.98 23.20
24
Bolt Shear
Force
Capacity Use
Num
Max Splice Forces
(kip) Load Case
(kip) /
Bolts
Bolt Type
Top Tension
66.64 60 deg No Ice
0.00 0
Top Compression
80.39 Normal No Ice
0.00 0
Bot Tension
83.10 60 deg No Ice
276.45 30
6 1 A325
Bot Compression
99.90 Normal No Ice
0.00 0
Page 4
Site Number: 81388
Location: Hazeltine, MN
Code: TIA/EIA-222 Rev F
Force/Stress Summary
Copyright Semaan Engineering Solutions, Inc
Y 613120091:49:08 PM
X
Section: 3 1.75
Bot Elev (ft): 30.00
Height (ft):
20.000
Shear Bear
Use
Top Compression
Max Tension Member
(kip) Load Case
(ksi) (kip) Bolts
Holes
Cap(kip) Cap(kip)
Bot Compression
Member
LEG 12B - 12"BD 1.75'
Shear
Bear
0
0.00 0.00
Force
Len
Bracing
%
Fa Cap Num
Num
Cap
Cap
Use
Max Compression Member
(kip) Load Case
(ft)
X
Y Z KL1R
(ksi) (kip) Bolts
Holes
(kip)
(kip)
% Controls
LEG 12B - 12"BD 1.75"
-75.38 Normal No Ice
10.02
100
100 100 0.0
0.0 258.77 0
0
0.00
0.00
29 User Input
HORIZ
0.00
0.000
0
0 0 0.0
0.0 0.00 0
0
0.00
0.00
0
DIAG SAE - 3X3X0.3125
-4.92 90 deg Ice
18.44
50
75 50 187.9
5.6 10.03 1
1
21.98
29.00
49 Member Z
Max Splice Forces
Force
Fy Cap Num
Num
Shear Bear
Use
Top Compression
Max Tension Member
(kip) Load Case
(ksi) (kip) Bolts
Holes
Cap(kip) Cap(kip)
Bot Compression
Controls
LEG 12B - 12"BD 1.75'
63.25 60 deg No Ice
50 288.64 0
0
0.00 0.00
21
User Input
HORIZ
0.00
0 0.00 0
0
0.00 0.00
0
Max Compression Member
DIAG SAE - 3=0.3125
4.65 90 deg No Ice
36 41.99 1
1
21.98 29.00
21
Bolt Shear
Max Splice Forces
Force
(kip) Load Case
Capacity Use Num
(kip) / Bolts Bolt Type
Top Tension
50.48 60 deg No Ice
0.00 0
Top Compression
60.74 Normal No Ice
0.00 0
Bot Tension
66.64 60 deg No Ice
276.45 24 6 1 A325
Bot Compression
80.39 Normal No Ice
0.00 0
Section: 4 1.5
Bot Elev (ft): 50.00
Height (ft):
20.000
Shear
Bear
Use
Max Tension Member
(kip) Load Case
(ksi) (kip) Bolts
Holes
Cap(kip) Cap(kip)
Member
Controls
Shear
Bear
50 211.98 0
0
Force
Len
Bracing %
Fa Cap Num
Num
Cap
Cap
Use
Max Compression Member
(kip) Load Case
(ft)
X
Y Z KLIR
(ksi) (kip) Bolts
Holes
(kip)
(kip)
% Controls
LEG 12B -12"BD 1.5'
-55.66 Normal No Ice
10.02
100
100 100 0.0
0.0 185.18 0
0
0.00
0.00
30 User Input
HORIZ
0.00
0.000
0
0 0 0.0
0.0 0.00 0
0
0.00
0.00
0
DIAG SAE - 3X3X0.1875
-4.33 90 deg Ice
16.80
50
75 50 169.2
7.0 7.58 1
1
21.98
17.40
57 MemberZ
Page 5
Force
Fy Cap Num
Num
Shear
Bear
Use
Max Tension Member
(kip) Load Case
(ksi) (kip) Bolts
Holes
Cap(kip) Cap(kip)
%
Controls
LEG 12B - 12'BO 1.5'
46.93 60 deg No Ice
50 211.98 0
0
0.00
0.00
22
User Input
HORIZ
0.00
0 0.00 0
0
0.00
0.00
0
DIAG SAE - 3X3X0.1875
4.26 90 deg No Ice
36 25.83 1
1
21.98
17.40
24
Bolt Bear
Force
Capacity Use
Num
Max Splice Forces
(kip) Load Case
(kip) %
Bolts Bolt Type
Top Tension
34.03 60 deg No Ice
0.00 0
Top Compression
41.33 Normal No Ice
0.00 0
Bot Tension
50.48 60 deg No Ice
276.45 18
6 1 A325
Bot Compression
60.74 Normal No Ice
0.00 0
Page 5
Site Number: 81388
Location: Hazeltine, MN
Code: TUUEIA-222 Rev F
Force/Stress Summary
Copyright Semaan Engineering Solutions, Inc
jl:120091:49:08 PM
Section: 5 1.5 Bot Elev (ft): 70.00 Height (ft): 20.000
Member Shear Bear
Force Len Bracing% Fa Cap Num Num Cap Cap Use
Max Compression Member (kip) Load Case (ft) X Y Z KUR (ksi) (kip) Bolts Holes (kip) (kip) % Controls
LEG 128 -17'BD 1.5" -36.50 Normal No Ice 10.02 100 100 100 0.0 0.0 185.18 0 0 0.00 0.00 19 User Input
HORIZ 0.00 0.000 0 0 0 0.0 0.0 0.00 0 0 0.00 0.00 0
DIAG SAE - 3X3X0.1875 -3.97 90 deg No Ice 15.24 50 75 50 153.4 8.5 9.22 1 1 21.98 17.40 43 Member Z
Member Shear Bear
Force Len Bracing % Fa Cap Num Num Cap Cap Use
Max Compression Member
Force
Fy Cap Num Num Shear Bear
Use
Max Tension Member
(Kip) Load Case
(ksi) (kip) Bolts Holes Cap (kip) Cap (kip)
/o Controls
LEG 128 -17'BD 1.5"
30.31 60 deg No Ice
50 211.98
0 0 0.00 0.00
14 User Input
HORIZ
0.00
0 0.00
0 0 0.00 0.00
0
DIAG SAE - 3X3X0.1875
3.94 90 deg No Ice
36 25.83
1 1 21.98 17.40
22 Bolt Bear
DIAG SAE - 2.SX2.5X0.1875
Force
Capacity Use
Num
7.9 7.09 1
Max Splice Forces
(kip) Load Case
(kip) %
Bolts Bolt Type
Force
Top Tension
17.32 60 deg No Ice
0.00 0
Top Compression
22.06 Normal No Ice
0.00 0
Cap (kip) Cap(kip)
%
Bot Tension
34.03 60 deg No Ice
276.45 12
6 1 A325
50 147.19
Bot Compression
41.33 Normal No Ice
0.00 0
User Input
Section: 6 1.25
Bot Elev (ft):
90.00
Height (ft): 25.000
21.98 17.40
Member Shear Bear
Force Len Bracing % Fa Cap Num Num Cap Cap Use
Max Compression Member
(kip) Load Case
(ft) X Y
Z KUR
(ksi) (kip) Bolts Holes
(kip) (kip)
% Controls
LEG 12B -12"BD 1.25"
-18.68 Normal No Ice
10.02 100 100
100 0.0
0.0 123.45 0
0
0.00 0.00
15 User Input
HORIZ SAE - 2.SX2.SX0.1875
-0.52 60 deg No Ice
7.500 100 100
100 181.8
6.0 5.43 1
1
21.98 17.40
9 Member Z
DIAG SAE - 2.SX2.5X0.1875
-4.99 Normal No Ice
13.12 50 75
50 159.1
7.9 7.09 1
1
21.98 17.40
70 Member Z
Force
Fy Cap Num Num
Shear Bear
Use
Max Tension Member
(kip) Load Case
(ksi) (kip) Bolts Holes
Cap (kip) Cap(kip)
%
Controls
LEG 128.12"BD 1.25"
15.46 60 deg No Ice
50 147.19
0 0
0.00 0.00
10
User Input
HORIZ SAE - 2.SX2.5X0.1875
0.46 Normal No Ice
36 20.38
1 1
21.98 17.40
2
Bolt Bear
DIAG SAE - 2.SX2.5X0.1875
4.89 60 deg No Ice
36 20.38
1 1
21.98 17.40
28
Bolt Bear
Force
Capacity Use
Num
Max Splice Forces
(kip) Load Case
(kip) %
Bolts Bolt Type
Top Tension
0.00
0.00 0
Top Compression
1.58 Normal Ice
0.00 0
Bot Tension
17.32 60 deg No Ice
276.45 6
6 1 A325
Bot Compression
22.06 Normal No Ice
0.00 0
Page 6
Site Number: 81388
Location: Hazeltine, MN
Code: TIAJEIA-222 Rev F
Support Forces Summary
Copyright Semaan Engineering Solutions, Inc
V &312009 1:49:08 PM
X
Page 7
FX
FY FZ
Load Case
Node (kip)
(kip) (kip)
(-) = Uplift (+) = Down
90 deq Ice
1 b
-12.72
-73.98 -6.37
Is
-8.01
93.83 3.67
1
-1.66
9.93 2.70
60 deq Ice
1b
-13.73
-86.28 -7.93
Is
-4.05
57.98 0.71
1
-1.41
58.08 -3.87
Normal Ice
1b
-7.49
-39.65 -6.06
1a
7.49
-39.65 -6.06
1
0.00
109.08 -10.91
90 deq No Ice
1b
-9.97
-78.74 4.80
1a
-10.87
92.53 5.34
1
-1.64
6.90 -0.54
60 deq No Ice
1 b
-10.96
-90.97 -6.32
1a
-6.86
55.77 2.36
1
-1.38
55.88 -7.12
Normal No Ice
1b
♦.79
-44.12 -4.50
to
4.79
-44.12 -4.50
1
0.00
108.93 -14.38
Max Uplift:
90.97 (kip)
Moment:
1,678.86 (ft -kip) Normal No Ice
Max Down:
109.08(kip)
Total Down:
20.69 (kip)
Max Shear:
15.86(kip)
Total Shear:
23.39 (kip)
Page 7
Load Case
69.28 mph Wind Normal To Face with Ice
69.28 mph Wind at 60 deg From Face with Ice
69.28 mph Wind at 90 deg From Face with Ice
80.00 mph Wind Normal To Face with No Ice
80.00 mph Wind at 60 deg From Face with No Ice
80.00 mph Wind at 90 deg From Face with No Ice
I
Site Number: 81388
Location: Hazeltine, MN
Code: TIA/EIA-222 Rev F
Deflections and Rotations
Elevation Deflection Twist
(ft) (ft) (deg)
Copyright Semaan Engineering Solutions, Inc
V 61312009 1:49:08 PM
X
Sway
(deg)
90.00
0.1723
0.0046
0.2019
115.00
0.2894
0.0204
0.5948
90.00
0.1678
0.0096
0.1938
115.00
0.2827
0.0263
0.5884
90.00
0.1687
0.0083
0.1912
115.00
0.2840
0.0182
0.5715
90.00
0.1782
0.0042
0.2127
115.00
0.3036
0.0218
0.6536
90.00
0.1718
0.0100
0.2020
115.00
0.2937
0.0288
0.6429
90.00
0.1734
0.0090
0.1994
115.00
0.2960
0.0202
0.6252
0.0000
0.0000
0.0000
Page 8
10/26/09 16:25 FAX AMERICAN TOWER Q002
AL
AMERICAN TOWER"
C O R f O N A T 1 O N
October 20, 2009
City of Chanhassen
Bob Generous, Senior Planner
7700 Market Blvd
PO Box 147
Chanhassen, MN 55317
RE: ITT Site Code: 173-21 Hazeltine
ATC Site Code: 81388 / Tower Address: 2290 LYMAN BLVD, Chanhassen, MN 55371
No Zoning — No Building Permit Letter
Dear Mr. Generous:
It was a pleasure speaking with you. As we discussed, I am a project manager with the American
Tower Corporation (ATC) and I represent ITT Corporation which is under lease agreement with
ATC to install FAA air traffic control equipment at an existing ATC telecommunications facility
in City of Chanhassen.
As we discussed, City of Chanhassen will not require a zoning permit or building permit for the
installation of the equipment cabinet, generator and collocation of the communications
equipment at the existing facility. The tower will not increase in height due to this installation_
Please acknowledge that no zoning and or building permit is required by signing in the space
provided below and e-mail to iulia muench(a)americantower.com or send via fax to 770-952-
4999 to my attention.
Should you have any questions or comments please contact James McInturf at 407-488-0524
I preciate our assistance in this matter.
Sincerely,
Julia Muench
Project Manager
American Tower Corporation
770-952-4999 (fax)
Julia muenchCalmnericantower.com
Acknowledged: Date:
Bob Generous, Senior Planner
4040 6ramblewwd Lane • TibiwIle, FL 32780.407-466-0524.677-257-3167 Fax • jemes.mclnWrfOamencantower.wm
THIS FILE
CONTAINS NO
DOCUMENTS
(Name and/or number on folder)