ARCH SITE PLAN REVIEW SET 11-2-23Chanhassen West Business Park Addition
Proposed Office / Warehouse - Lot 3
for:
Chanhassen, MN
OUTLOT A a
- WETLAND
PROJECT
T
ILOCATW
OVERALL SITE PLAN
NO SCALE
NORTH
W E
S
SHEET INDEX
SHEET #
HOUWMAN ARCHITECTS
SITE PLAN SUBMITTAL SET
10-31-23
A1.0
PROJECT INFORMATION
INCLUDED
A2.0
OFFICE FLOOR PLANS
INCLUDED
A3.0
EXTERIOR ELEVATIONS / RENDERS
INCLUDED
Building Square Footage Breakdown
Use
Office
Light Industrial /Warehouse
Total (Maximum)
Percent Total
Square Feet
30%
115,500
70%
261,500
377,000
THE PUD STANDARD FOR HARD SURFACE COVERAGE IS 70% FOR OFFICE AND INDUSTRIAL USES.
ANY ONE SITE/LOT CAN EXCEED THE 70 PERCENT REQUIREMENT,
BUT IN NO CASE CAN THE ENTIRE FINISHED DEVELOPMENT EXCEED 70 PERCENT.
Building and Site Coverage estimates:
Lot
Lot Area (acres)
Building area (sq. ft.)
PUD Bldg.area
Site
Site
Estimate
coverage
Coverage
F.A.R. 0.28(sq. ft.)
(acres)
(%)
Lot 3+ pt 1 &
2 B 1
7.4
110,000
97,300
5.1
69
(Waytek)
Pt Lot 1 & 2,
2.65
30,000 est.
25,300
1.85
70
B1
Lot 1, B 2
3.8
50,000
46,500
2.66
70
(BIG/SNAP)
Lot 2, B2
3.32
46,152
40,300
2.65
80
(Building 2)
Lot 3, B2
(CW III)
2.85
33,283
34,800
2.19
77
Lot 4, B2
5.0
49,700
61,400
3.1
62
(Minger)
Lot 5, B2
(Outset)
3.58
48,000
43,700
2.5
70
Outlot C
0
0
0
Total
32.4
367,135
349,300
20.05
62
BUILDING TOTAL = 33,283 S.F.
AFFINITECH TOTAL USEABLE SPACE - 23,955 S.F.
OFFICE TOTAL USEABLE SPACE= 11,729 S.F.
WAREHOUSE TOTAL USEABLE SPACE= 12,226 S.F.
TENANT TOTAL USEABLE SPACE - 12,390 S.F.
OFFICE TOTAL USEABLE SPACE = 4,546 S.F.
WAREHOUSE TOTAL USEABLE SPACE = 6,615 S.F.
Lu
z
J
Lu
a.
0
a
AFFINITECH
NEW TOTAL
PROPERTY LINE
NORTH ENTRY
MONUMENT
AND UTILITY EAST SIGN
FIRE
HYD T
9
TENANT
MAIN FL,
TENANT
WAREHOUSE
I
SHAREQ
RECYCLING
REFUSES
ENCLO�URE
W/ CMU
BLOCK
MATCHI G
PRECA T
PANELS' &
METAL
GATE
�P
SURMOUNTABLE CURB 1
-- - -
DRAINAGE AND UTILITY EASEMENT
PROPERTY LINE - -
NORTH
=,SITE PLAN W E
A1.0 NO SCALE -6
S
CHANHASSEN WEST BUSINESS PARK
DEVELOPMENT DESIGN STANDARDS
BUILDING SITE COVERAGE AREAS
LOT 3 BLOCK 2
SITE AREA = 122,832 S.F.
BUILDING AREA = 33,283 S.F.
HARDCOVER = 95,361 S.F.
SITE HARDCOVER COVERAGE 77%
SETBACKS
The development is regulated by the PUD Standards. There are no minimum requirements
for setbacks on interior lot lines in the PUD zone, except as specified below.
The following building and parking setbacks shall apply:
Buffer yard, Setback
building/parking (ft.)
Galpin Blvd.
C, 50, 50
Lyman Blvd.
Street A
Interior Lot Lines
C, 50, 20 (amended 4/10/06)
NA, 30, 10
B, 0, 0
West Perimeter Lot Line (adjacent to
industrial)
C, 30, 20
North Perimeter Lot Line (adjacent to
residential): Buffer yard & setback
D, 100 , 100
PARKING REQUIREMENTS
OFFICE S.F. 16,275 S.F. / 1,000 = 16 X 5 = 80 PARKING SPACES
WAREHOUSE 18,841 S.F. 1 STALL FOR EACH 1000 S.F. FOR 1ST 10K S.F.
1 SPACE FOR EACH ADDITIONAL 2,000 S.F.
8,841 / 2000 = 4
10 + 4 = 14 STALLS
94 STALLS REQUIRED
74 STALLS PROVIDED
20 SHOWN FOR PROOF OF PARKING
N
5 \ Z
0
C
I
I
I�
I
I�
D
I Z
Im
I o �
I
10 I m
m
I z
I
44 - II
FIRE DEPT. - I �
CONNECTION I N
m'
1�
v
�m
s
>,
SO)UT
ENTRY
MONUMENT) ,'
� P.0
NORTH
2 FLOOR PLAN
A1.o E SCALE: 1 /16" = 1'-0" W
S
BUILDING TO HAVE FIRE SPRINKLER SYSTEM
SPECIFIC TYPE TO BE DETERMINED
OCCUPANCY & OCCUPANCY LOADS
ARCHITECT:
I
HOUWMAN
ARCHITECTS
20465 ZEA ST NW
OAK GROVE, MN 55303
651-631-0200
NICKHOUWMAN@GMAIL.COM
I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION OR REPORT
WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION
AND THAT I AM A DULY REGISTERED ARCHITECT UNDER THE LAWS
OF THE STATE OF MINNESOTA
NAME
BRIAN HOUWMAN
REGISTRATION NO.
22604 DATE 9.6-23
PROJECT LOCATION:
LOT 3, BLOCK 2
CHANHASSEN, MN
CLIENT:
GENERAL CONTRACTOR:
EDEN TRACE
MARK UNDESTAD
612-803-6970
NOTE:
THIS SET OF PLANS IS FOR A
DESIGN -BUILD PROJECT.
ANY INFORMATION NOT CLARIFIED
BY MANUFACTURER, PERFORMANCE
REQUIREMENTS OR DETAILS ON THIS
PLAN SET ARE
TO BE DETERMINED
BY THE GENERAL CONTRACTOR
AND THE OWNER.
ANY DISCREPANCIES BETWEEN PLANS
AND FIELD CONDITIONS WHICH REQUIRE
THE CONTRACTOR TO CHOOSE
ONE METHOD, DIMENSION
OR MATERIAL OVER ANOTHER ARE TO
BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT
BEFORE WORK IS STARTED,
FOR CLARIFICATION.
FULL SIZE PLANS 24" X 36"
REVIEW SET 9-6-23
SCHEMATIC DESIGN 10-25-23
SITE PLAN SUBMITTAL 10.31.23
JOB#
23.134
DATE
9-6-23
DRAWN
NH
CHECKED
BH
AFFINITECH
GROUP B OFFICE / GROUP S-2 WAREHOUSE
OFFICE ESTIMATED OCCUPANT LOAD = 78 OCCUPANTS
WAREHOUSE ESTIMATED OCCUPANT LOAD = 24 OCCUPANTS
TOTAL PROJECTED # OF EMPLOYEES = 35 EMPLOYEES SITE PLAN
TENANT
GROUP B OFFICE / GROUP S-2 WAREHOUSE
OFFICE ESTIMATED OCCUPANT LOAD = 30 OCCUPANTS
WAREHOUSE ESTIMATED OCCUPANT LOAD = 13 OCCUPANTS Al 00
TOTAL PROJECTED # OF EMPLOYEES = 12 EMPLOYEES
14
MAIN FLOOR OFFICE PLAN
SCALE: 3/32" = 1'-O"
NORTH
W r �- E
S
MEZZANINE FLOOR OFFICE PLAN
SCALE : 3/32" = 1'-O"
MAIN FLOOR OFFICE
8,978 USEABLE S.F.
NORTH
W E
S
2ND FLOOR OFFICE
2,751 USEABLE S.F.
MAIN FLOOR OFFICE PLAN
SCALE : 3/32" = 1'-O"
NORTH
W -E
S
MEZZANINE FLOOR OFFICE PLAN
SCALE : 3/32" = 1'-O"
MAIN FLOOR OFFICE
2,592 USEABLE S.F.
NORTH
W E
S
OFFICE MEZZANINE
1,954 USEABLE S.F.
ARCHITECT:
HOUWMAN
ARCHITECTS
20465 ZEA ST NW
OAK GROVE, MN 55303
651-631-0200
NICKHOUWMAN@GMAIL.COM
I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION OR REPORT
WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION
AND THAT I AM A DULY REGISTERED ARCHITECT UNDER THE LAWS
OF THE STATE OF MINNESOTA
NAME
BRIAN HOUWMAN
REGISTRATION NO. 22604 DATE 9.6-23
PROJECT LOCATION:
LOT 3, BLOCK 2
CHANHASSEN, MN
CLIENT:
GENERAL CONTRACTOR:
EDEN TRACE
MARK UNDESTAD
612-803-6970
iinTF-
THIS SET OF PLANS IS FOR A
DESIGN -BUILD PROJECT.
ANY INFORMATION NOT CLARIFIED
BY MANUFACTURER, PERFORMANCE
REQUIREMENTS OR DETAILS ON THIS
PLAN SET ARE
TO BE DETERMINED
BY THE GENERAL CONTRACTOR
AND THE OWNER.
ANY DISCREPANCIES BETWEEN PLANS
AND FIELD CONDITIONS WHICH REQUIRE
THE CONTRACTOR TO CHOOSE
ONE METHOD, DIMENSION
OR MATERIAL OVER ANOTHER ARE TO
BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT
BEFORE WORK IS STARTED,
FOR CLARIFICATION.
FULL SIZE PLANS 24" X 36"
REVIEW SET 9-6-23
SCHEMATIC DESIGN 10-25-23
SITE PLAN SUBMITTAL 10.31.23
JOB# 23.134
DATE 9-6-23
J11: ► ►l
CHECKED BH
FLOOR PLAN
A200
ARCHITECT:
SCOPE OF PROJECT:
OFFICE/WAREHOUSE BUILDING CONSTRUCTED OF:
ARCHITECTURAL PRECAST CONCRETE WALL PANELS WITH REVEALS
STEEL ROOF BAR JOISTS - STEEL ROOF DECK
ALUMINUM FRAMED WINDOWS & DOORS
ARCHITECTURAL ACCENT LIGHTING AT ENTRIES
SITE WORK / GRADING OF SITE / ASPHALT - LANDSCAPING.
SOUTH EAST PERSPECTIVE
NO SCALE
STEEL FRAMED CARPORT
WITH PATIO ABOVE
PATIO TO HAVE ROOF PAVERS & METAL GUARDRAILS
f
2-STORY BUILDING -
TOP OF BUILDING PARAPET WALL 30'
MAIN ENTRY - TOP OF PARAPET 34'
FAUX WOOD ACCENTS AT AWNINGS / FAUX PILASTERS
HIGHER QUALITY METAL BANDED SWEEPS DESIGN ELEMENTS
SOUTH PERSPECTIVE
NO SCALE
lilr.
" m111 �illii I►i
AL alW.
3
NORTH EAST PERSPECTIVE
NO SCALE
LOADING DOCKS AT REAR OF BUILDING
WEST PERSPECTIVE
NO SCALE
HIGHER QUALITY METAL BANDED SWEEPS DESIGN ELEMENTS
TENANT SIGNAGE TO BE DETERMINED
HOUWMAN
ARCHITECTS
20465 ZEA ST NW
OAK GROVE, MN 55303
651-631-0200
NICKHOUWMAN@GMAIL.COM
I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION OR REPORT
WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION
AND THAT I AM A DULY REGISTERED ARCHITECT UNDER THE LAWS
OF THE STATE OF MINNESOTA
NAME
BRIAN HOUWMAN
REGISTRATION NO.
22604 DATE 9.6-23
PROJECT LOCATION:
LOT 3, BLOCK 2
CHANHASSEN, MN
CLIENT:
GENERAL CONTRACTOR:
EDEN TRACE
MARK UNDESTAD
612-803-6970
NOTE:
THIS SET OF PLANS IS FOR A
DESIGN -BUILD PROJECT.
ANY INFORMATION NOT CLARIFIED
BY MANUFACTURER, PERFORMANCE
REQUIREMENTS OR DETAILS ON THIS
PLAN SET ARE
TO BE DETERMINED
BY THE GENERAL CONTRACTOR
AND THE OWNER.
ANY DISCREPANCIES BETWEEN PLANS
AND FIELD CONDITIONS WHICH REQUIRE
THE CONTRACTOR TO CHOOSE
ONE METHOD, DIMENSION
OR MATERIAL OVER ANOTHER ARE TO
BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT
BEFORE WORK IS STARTED,
FOR CLARIFICATION.
FULL SIZE PLANS 24" X 36"
REVIEW SET 9-6-23
SCHEMATIC DESIGN 10-25-23
SITE PLAN SUBMITTAL 10.31.23
JOB#
23.134
DATE
9-6-23
DRAWN
NH
CHECKED
BH
EXTERIOR
PERSPECTIVES
A300