Loading...
01-09-2024 EDC Agenda PacketA.5:30 P.M. - CALL TO ORDER B.APPROVAL OF AGENDA Commissioners may add or delete items at this time. C.APPROVAL OF MINUTES C.1 Approve Economic Development Commission Minutes of December 12, 2023. D.VISITOR PRESENTATIONS E.DISCUSSION / GENERAL BUSINESS ITEMS E.1 West 78th Street Renewal and Renovation TIF District Application - Roers F.DIRECTOR'S REPORT G.ADJOURNMENT AGENDA CHANHASSEN ECONOMIC DEVELOPMENT COMMISSION TUESDAY, JANUARY 9, 2024 FOUNTAIN CONFERENCE ROOM, 7700 MARKET BOULEVARD 1 Economic Development Commission Item January 9, 2024 Subject Approve Economic Development Commission Minutes of December 12, 2023. Section APPROVAL OF MINUTES Item No: C.1 Prepared By Amy Weidman, Admin Support Specialist File No: SUMMARY BACKGROUND DISCUSSION RECOMMENDATION Staff recommends that the Economic Development Commission approve the December 12, 2023 Commission minutes. ATTACHMENTS EDC Minutes dated December 12, 2023 2 CHANHASSEN ECONOMIC DEVELOPMENT COMMISSION REGULAR MEETING DECEMBER 12, 2023 Chair Anderson called the meeting to order at 5:30 p.m. MEMBERS PRESENT: Chair Eric Anderson, Vice Chair Duke Zurek, Chris Freeman, Stacy Goff, Cohen Lee MEMBERS ABSENT: Luke Bame STAFF PRESENT: Samantha DiMaggio, Economic Development Manager PUBLIC PRESENT: None. Commissioner Zurek moved, and Commissioner Goff seconded to approve the agenda. All voted in favor and the motion carried unanimously with a vote of 5 to 0. APPROVAL OF MINUTES: APPROVE ECONOMIC DEVELOPMENT COMMISSION MINUTES DATED NOVEMBER 14, 2023 Commissioner Goff moved, and Commissioner Freeman seconded to approve the Minutes of the Economic Development Commission meeting dated November 14, 2023, as presented. All voted in favor and the motion carried unanimously with a vote of 5 to 0. DISCUSSION/GENERAL BUSINESS ITEMS: 1. Tax Increment Financing- Public Economic Development Manager, Samantha DiMaggio, had a follow-up discussion with the EDC on Tax Increment Financing (TIF). They discussed the best ways to educate the public about TIF and how it works. ADJOURNMENT: Commissioner Zurek moved, and Commissioner Lee seconded to adjourn the meeting. All voted in favor and the motion carried unanimously with a vote of 5 to 0. The Economic Development Commission meeting was adjourned at 6:00 p.m. Submitted by Samantha DiMaggio Economic Development Manager 3 Economic Development Commission Item January 9, 2024 Subject West 78th Street Renewal and Renovation TIF District Application - Roers Section DISCUSSION / GENERAL BUSINESS ITEMS Item No: E.1 Prepared By Sam DiMaggio, Economic Development Manager File No: SUMMARY Roers is requesting the establishment of a Renewal and Renovation Tax Increment Financing (TIF) District to assist with the redevelopment of the Chanhassen Cinema and the County Inn & Suites. The Chanhassen Cinema has been vacant since April 2023 and the hotel which has a lot of deferred maintenance but is still in operation at this time. LHB has completed an analysis of both buildings, which is attached for review, and they meet the statutory requirements for the Renewal and Renovation District. Roers is proposing to construct two new vertical mixed-use buildings. Each building would include both residential and commercial space as well as underground parking. The total redevelopment is estimated to cost $134.6 million. The developer is showing a financing gap of $6.2 million which is why they are requesting TIF assistance. The funds generated from the TIF District will be used to pay for demolition and site work, including stormwater, utilities, and the extension of Laredo Drive. State statute establishes these expenses as eligible to be paid for through TIF. This would be a "pay-as-you-go" TIF, which means that the taxes would be paid by the owner/developer and would be rebated once it is determined that the expenditures are valid and the goals of the project are met. Pay-as-you-go financing relies on the private developer or property owner to initially finance the costs of the TIF improvements. A development agreement between the authority and the developer then provides the developer will be repaid as tax increments are collected. This form of TIF structuring removes financial risk to the city. Ehlers, the city's financial consultant, will present their findings to the EDC and the developer will also attend the meeting to answer any questions. BACKGROUND A Renewal and Renovation District would be established to assist with redeveloping sites that contain substandard buildings and buildings that require substantial renovation and clearance. A renovation and renewal TIF district has a maximum term of 16 years of increment. 4 DISCUSSION RECOMMENDATION Motion to recommend that the City Council, acting as the Economic Development Authority, approve the request to establish a renewal and renovation TIF district and enter into a development contract for TIF assistance with the applicant. ATTACHMENTS West 78th Street Renewal & Renovation TIF Report LHB Business Subsidy Application - Roers Property Aerial 5 REPORT OF INSPECTION PROCEDURES AND RESULTS FOR DETERMINING QUALIFICATIONS OF A TAX INCREMENT FINANCING DISTRICT WEST 78TH STREET RENEWAL AND RENOVATION TIF DISTRICT Prepared for CITY OF CHANHASSEN, MINNESOTA DECEMBER 1, 2023 6 West 78th Street Renewal and Renovation TIF LHB Project No. 230558.00 Page 1 of 12 Final Report  Table of Contents   Part 1 – Executive Summary ....................................................................................................................... 2 Purpose of Evaluation ............................................................................................................................................... 2 Scope of Work ........................................................................................................................................................... 3 Conclusion ................................................................................................................................................................ 3 Part 2 – Minnesota Statute 469.174, Subdivision 10a Requirements ...................................................... 3  A. Coverage Test .................................................................................................................................................. 4 B. Condition of Buildings Test ............................................................................................................................... 4 C. Distribution of Substandard Buildings ............................................................................................................... 5 Part 3 – Procedures Followed .................................................................................................................... 6  Part 4 – Findings .......................................................................................................................................... 6  A. Coverage Test .................................................................................................................................................. 6 B. Condition of Building Test .................................................................................................................................. 8 1. Building Inspection .................................................................................................................................. 8 2. Replacement Cost .................................................................................................................................. 8 3. Code Deficiencies ................................................................................................................................... 8 4. System Condition Deficiencies ............................................................................................................... 9 C. Distribution of Substandard Structures ........................................................................................................... 10 Part 5 - Team Credentials .......................................................................................................................... 12  APPENDIX A Property Condition Assessment Summary Sheet APPENDIX B Building Code and Condition Deficiencies Reports APPENDIX C Property Condition Assessment Building Replacement Cost Reports Code Deficiency Cost Reports Photographs 7 West 78th Street Renewal and Renovation TIF LHB Project No. 230558.00 Page 2 of 12 Final Report  Part 1: Executive Summary Purpose of the Evaluation LHB was hired by the City of Chanhassen to inspect and evaluate the properties within a Tax Increment Financing Renewal and Renovation District (“TIF District”) proposed to be established by the City. The proposed TIF District is bounded by West 78th Street, Market Boulevard, and Market Street (see Diagram 1). The purpose of LHB’s work is to determine whether the proposed TIF District meets the statutory requirements for coverage, and whether two (2) buildings on six (6) parcels located within the proposed TIF District, meet the qualifications required for a Renewal and Renovation District. Diagram 1: Proposed TIF District 8 West 78th Street Renewal and Renovation TIF LHB Project No. 230558.00 Page 3 of 12 Final Report  Scope of Work The proposed TIF District consists of six (6) parcels with two (2) buildings. Both buildings in the proposed TIF District received interior and exterior inspections. The Chanhassen Cinema building was determined substandard. The Hotel building did not meet the qualifications to be determined “structurally substandard”, but a full building report was still completed showing significant structural and code deficiencies coming up just short of the 15 percent code deficiency requirement. Building code and Condition Deficiency reports for both buildings are in Appendix B. Conclusion After inspecting and evaluating the properties within the proposed TIF District and applying current statutory criteria for a Renewal and Renovation District under Minnesota Statutes, Section 469.174, Subdivision 10a, it is our professional opinion that the proposed TIF District qualifies as a Renewal and Renovation District because:  The proposed TIF District has a coverage calculation of 100 percent which is above the 70 percent requirement.  50 percent of the buildings are structurally substandard which is above the 20 percent requirement.  100 percent of the other buildings require substantial renovation or clearance which is above the 30 percent requirement.  The substandard buildings are reasonably distributed. The remainder of this report describes our process and findings in detail. Part 2: Minnesota Statute 469.174, Subdivision 10a Requirements The properties were inspected in accordance with the following requirements under Minnesota Statutes, Section 469.174, Subdivision 10(c), which states: Interior Inspection “The municipality may not make such determination [that the building is structurally substandard] without an interior inspection of the property...” Exterior Inspection and Other Means “An interior inspection of the property is not required, if the municipality finds that (1) the municipality or authority is unable to gain access to the property after using its best efforts to obtain permission from the party that owns or controls the property; and (2) the evidence otherwise supports a reasonable conclusion that the building is structurally substandard.” 9 West 78th Street Renewal and Renovation TIF LHB Project No. 230558.00 Page 4 of 12 Final Report  Documentation “Written documentation of the findings and reasons why an interior inspection was not conducted must be made and retained under section 469.175, subdivision 3(1).” Qualification Requirements Minnesota Statutes, Section 469.174, Subdivision 10 (a) (1) requires two tests for occupied parcels: A. COVERAGE TEST 1. Minnesota Statutes, Section 469.174, Subdivision 10 (a) (1) states: …“parcels consisting of 70 percent of the area of the district are occupied by buildings, streets, utilities, or paved or gravel parking lots” The coverage required by the parcel to be considered occupied is defined under Minnesota Statutes, Section 469.174, Subdivision 10(e), which states:“For purposes of this subdivision, a parcel is not occupied by buildings, streets, utilities, or paved or gravel parking lots unless 15 percent of the area of the parcel contains building, streets, utilities, or paved or gravel parking lots, or other similar structures.” B. CONDITION OF BUILDINGS TEST 1. Minnesota Statutes, Section 469.174, Subdivision 10(a) states: …“20 percent of the buildings are structurally substandard; and 30 percent of the other buildings require substantial renovation or clearance to remove existing conditions such as: inadequate street layout, incompatible uses or land use relationships, overcrowding of buildings on the land, excessive dwelling unit density, obsolete buildings not suitable for improvement or conversion, or other identified hazards to the health, safety, and general well-being of the community.” Structurally substandard is defined under Minnesota Statues, Section 469.174, Subdivision 10(b), “For purposes of this subdivision, ‘structurally substandard’ shall mean containing defects in structural elements or a combination of deficiencies in essential utilities and facilities, light and ventilation, fire protection including adequate egress, layout and condition of interior partitions, or similar factors, which defects or deficiencies are of sufficient total significance to justify substantial renovation or clearance.” a. We do not count energy code deficiencies toward the thresholds required by Minnesota Statutes, Section 469.174, Subdivision 10(b) defined as “structurally substandard”, due to concerns expressed by the State of Minnesota Court of Appeals in the Walser Auto Sales, Inc. vs. City of Richfield case filed November 13, 2001. 2. Buildings are not eligible to be considered structurally substandard unless they meet certain additional criteria, as set forth in Subdivision 10(c) which states: “A building is not structurally substandard if it follows the building code applicable to new buildings or could be modified to satisfy the building code at a cost of less than 15 percent of the cost of constructing a new structure of the same square footage and type on the site. The municipality may find that a building is not disqualified as structurally substandard under the preceding sentence based on reasonably available evidence, such as the size, type, and age of the building, the average cost of plumbing, electrical, or structural repairs, or other similar reliable evidence.” “Items of evidence that support such a conclusion [that the building is not disqualified] include recent fire or police inspections, on-site property appraisals or housing inspections, exterior evidence of deterioration, or other similar reliable evidence.” 10 West 78th Street Renewal and Renovation TIF LHB Project No. 230558.00 Page 5 of 12 Final Report  i. LHB counts energy code deficiencies toward the 15 percent code threshold required by Minnesota Statutes, Section 469.174, Subdivision 10(c) for the following reasons: 1) The Minnesota energy code is one of ten building code areas highlighted by the Minnesota Department of Labor and Industry website where minimum construction standards are required by law. 2) Chapter 13 of the 2015 Minnesota Building Code states, “Buildings shall be designed and constructed in accordance with the International Energy Conservation Code.” Further more, Minnesota Rules, Chapter 1305.0021 Subpart 9 states, “References to the International Energy Conservation Code in this code mean the Minnesota Energy Code…” 3) Chapter 11 of the 2015 Minnesota Residential Code incorporates Minnesota Rules, Chapters, 1322 and 1323 Minnesota Energy Code. 4) The Senior Building Code Representative for the Construction Codes and Licensing Division of the Minnesota Department of Labor and Industry confirmed that the Minnesota Energy Code is being enforced throughout the State of Minnesota. 5) In a January 2002 report to the Minnesota Legislature, the Management Analysis Division of the Minnesota Department of Administration confirmed that the construction cost of new buildings complying with the Minnesota Energy Code is higher than buildings built prior to the enactment of the code. 6) Proper TIF analysis requires a comparison between the replacement value of a new building built under current code standards with the repairs that would be necessary to bring the existing building up to current code standards. For an equal comparison to be made, all applicable code chapters should be applied to both scenarios. Since current construction estimating software automatically applies the construction cost of complying with the Minnesota Energy Code, energy code deficiencies should also be identified in the existing structures. C. DISTRIBUTION OF SUBSTANDARD BUILDINGS 1. Minnesota Statutes, Section 469.174, Subdivision 10a. (a) (2), states that the conditions described above must be “reasonably distributed throughout the geographic area of the district”. 2. Our interpretation of the distribution requirement is that the substandard buildings and other buildings requiring substantial renovation or clearance must be reasonably distributed throughout the district as compared to the location of all buildings in the district. For example, if all the buildings in a district are located on one half of the area of the district, with the other half occupied by parking lots (meeting the required 70 percent coverage for the district), we would evaluate the distribution of the substandard buildings and buildings requiring substantial renovation or clearance compared with only the half of the district where the buildings are located. If all the buildings in a district are located evenly throughout the entire area of the district, the substandard buildings and buildings requiring substantial renovation or clearance must be reasonably distributed throughout the entire area of the district. We believe this is consistent with the opinion expressed by the State of Minnesota Court of Appeals in the Walser Auto Sales, Inc. vs. City of Richfield case filed November 13, 2001. 11 West 78th Street Renewal and Renovation TIF LHB Project No. 230558.00 Page 6 of 12 Final Report  Part 3: Procedures Followed LHB was able to schedule interior and exterior inspections for two (2) buildings in the proposed TIF District on July 27, 2023. The Chanhassen Cinema building (570 Market Street, Parcel A in Diagram 2) received an on-site interior and exterior inspection and was determined substandard. The Hotel building (575 and 591 78th Street West, Parcels B, C, and E in Diagram 2) including the former High Timber Lodge addition, had visible water issues but did not appear to have enough condition deficiencies during the initial inspection to be considered “structurally substandard”. However, the Hotel building did exhibit existing conditions warranting renovation or clearance as defined by Minnesota Statutes Subd. 10a. (1) (iii) in which it requires substantial renovation or clearance to remove existing conditions of incompatible land use relationships and obsolete buildings not suitable for improvement or conversion. Part 4: Findings A. COVERAGE TEST 1. The total square foot area of each parcel in the proposed TIF District was obtained from City records, GIS mapping and site verification. 2. The total square foot area of buildings and site improvements on the parcels in the proposed TIF District was obtained from City records, GIS mapping and site verification. 3. The percentage of coverage for each parcel in the proposed TIF District was computed to determine if the 15 percent minimum requirement was met. The total square footage of parcels meeting the 15 percent requirement was divided into the total square footage of the entire district to determine if the 70 percent requirement was met. FINDING: The proposed TIF District met the coverage test under Minnesota Statutes, Section 469.174, Subdivision 10(e), which resulted in parcels consisting of 100 percent of the area of the proposed TIF District being occupied by buildings, streets, utilities or paved drives or parking lots (see Diagram 2). This exceeds the 70 percent area coverage requirement for the proposed TIF District under Minnesota Statutes, Section 469.174, Subdivision 10a (a)(1). 12 West 78th Street Renewal and Renovation TIF LHB Project No. 230558.00 Page 7 of 12 Final Report  Diagram 2: Coverage Shaded area denotes parcels more than 15 percent occupied by buildings, streets, utilities or paved or gravel parking lots or other similar structures. 13 West 78th Street Renewal and Renovation TIF LHB Project No. 230558.00 Page 8 of 12 Final Report  B. Condition Of Building Test 1. BUILDING INSPECTION The first step in the evaluation process is the building inspection. After an initial walk-thru, the inspector makes a judgement whether a building “appears” to have enough defects or deficiencies of sufficient total significance to justify substantial renovation or clearance. If it does, the inspector documents with notes and photographs code and non-code deficiencies in the building. 2. REPLACEMENT COST The second step in evaluating a building to determine if it is substandard to a degree requiring substantial renovation or clearance is to determine its replacement cost. This is the cost of constructing a new structure of the same square footage and type on site. Replacement costs were researched using R.S. Means Cost Works square foot models for 2023. A replacement cost was calculated by first establishing building use (office, retail, residential, etc.), building construction type (wood, concrete, masonry, etc.), and building size to obtain the appropriate median replacement cost, which factors in the costs of construction in Chanhassen, Minnesota. Replacement cost includes labor, materials, and the contractor’s overhead and profit. Replacement costs do not include architectural fees, legal fees or other “soft” costs not directly related to construction activities. Replacement cost for each building that was inspected is tabulated in Appendix A. 3. CODE DEFICIENCIES The next step in evaluating a building is to determine what code deficiencies exist with respect to such building. Code deficiencies are those conditions for a building which are not in compliance with current building codes applicable to new buildings in the State of Minnesota. Minnesota Statutes, Section 469.174, Subdivision 10(c), specifically provides that a building cannot be considered structurally substandard if its code deficiencies are not at least 15 percent of the replacement cost of the building. As a result, it was necessary to determine the extent of code deficiencies for each building in the proposed TIF District. The evaluation was made by reviewing all available information with respect to such buildings contained in City Building Inspection records and making interior and exterior inspections of the buildings. LHB utilizes the current Minnesota State Building Code as the official code for our evaluations. The Minnesota State Building Code is a series of provisional codes written specifically for Minnesota only requirements, adoption of several international codes, and amendments to the adopted international codes. After identifying the code deficiencies in each building, we used R.S. Means Cost Works 2023; Unit and Assembly Costs to determine the cost of correcting the identified deficiencies. We were than able to compare the correction costs with the replacement cost of each building to determine if the costs for correcting code deficiencies exceed the required 15 percent threshold. FINDING: One (1) out of Two (2) buildings (50 percent) in the proposed TIF District contained code deficiencies exceeding the 15 percent threshold required by Minnesota Statutes, Section 469.174, Subdivision 10(c). Complete Building Code and Condition Deficiency Reports for the building that was inspected in the proposed TIF District can be found in Appendix B of this report. 14 West 78th Street Renewal and Renovation TIF LHB Project No. 230558.00 Page 9 of 12 Final Report  4. SYSTEM CONDITION DEFICIENCIES If a building meets the minimum code deficiency threshold under Minnesota Statutes, Section 469.174, Subdivision 10(c), then for such building to be “structurally substandard” under Minnesota Statutes, Section 469.174, Subdivision 10(b), the building’s defects, or deficiencies should be of sufficient total significance to justify “substantial renovation or clearance.” Based on this definition, LHB re-evaluated each of the buildings that met the code deficiency threshold under Minnesota Statutes, Section 469.174, Subdivision 10(c), to determine if the total deficiencies warranted “substantial renovation or clearance” based on the criteria we outlined above. System condition deficiencies are a measurement of defects or substantial deterioration in site elements, structure, exterior envelope, mechanical and electrical components, fire protection and emergency systems, interior partitions, ceilings, floors, and doors. The evaluation of system condition deficiencies was made by reviewing all available information contained in City records and making interior and exterior inspections of the buildings. LHB only identified system condition deficiencies that were visible upon our inspection of the building or contained in City records. We did not consider the amount of “service life” used up for a particular component unless it was an obvious part of that component’s deficiencies. After identifying the system condition deficiencies in each building, we used our professional judgment to determine if the list of defects or deficiencies are of sufficient total significance to justify “substantial renovation or clearance.” FINDING: In our professional opinion, one (1) of the two (2) buildings (50 percent) in the proposed TIF District is structurally substandard to a degree requiring substantial renovation or clearance, because of defects in structural elements or a combination of deficiencies in essential utilities and facilities, light and ventilation, fire protection including adequate egress, layout and condition of interior partitions, or similar factors which defects or deficiencies are of sufficient total significance to justify substantial renovation or clearance. This exceeds the 20 percent requirement of Subdivision 10a. (a) (1) (ii). SUBDIVISION 10a. (a) (1) (iii) Subdivision 10a. (a) (1) (iii) requires that at least 30 percent of the other buildings (i.e., all buildings excluding the 20 percent minimum standard) meet the Subdivision 10a (1), clause (iii) test in which the “other” buildings require substantial renovation or clearance to remove existing conditions such as: inadequate street layout, incompatible uses or land use relationships, overcrowding of buildings on the land, excessive dwelling unit density, obsolete buildings not suitable for improvement or conversion, or other identified hazards to the health, safety, and general well-being of the community. FINDING: One (1) out of the one (1) remaining buildings (100 percent) in the proposed Renewal and Renovation District exhibits existing conditions warranting renovation or clearance as defined by Minnesota Statutes Subd. 10a. (1) (iii), described as follows: 15 West 78th Street Renewal and Renovation TIF LHB Project No. 230558.00 Page 10 of 12 Final Report  PARCEL B, C, and E: In 2023 the City of Chanhassen began a visioning process for the future of Downtown Chanhassen, which is typically referred to as the areas surrounding West 78th Street between Powers Boulevard and Great Plains Boulevard. The downtown plan, generated from the visioning process, showed a desire for a more walkable, pedestrian-scale downtown with buildings near the streets and parking tucked to the rear, side, or underground. The continued addition of housing opportunities within the downtown is also seen as a priority to increase the number of people within the downtown area at all times of the day to promote a healthy business climate. Over time, West 78th Street will be transformed into more of a traditional 'main street' with on-street parking opportunities, contiguous sidewalks, and opportunities to eat, shop, and recreate. The new civic campus currently being planned by the city will consist of a new city hall, senior city, and city park. The city park will include a splash pad, and an outdoor performance center and winter ice skating to serve as a draw attracting the public to downtown Chanhassen year-round. The new city hall will be located at the intersection of Market Boulevard and West 78th Street and will set the tone for building placement for future downtown developments and redevelopment projects. The City has a vision for this area that is a departure from the suburban Hotel model. Concurrent with the City plans changing for this area, the Hotel ownership group is faced with water penetration issues on the exterior skin of the hotel that if not addressed, will lead to serious consequences. The building has been well-maintained to this point, but will become more difficult to maintain and costly to fix. LHB inspectors found code deficiencies totaling 14.4% of the replacement value of the building. While this is slightly short of what is required to be labeled a “substandard” building by MN TIF Statutes, it is a significant issue for the owners and will impact the viability of this building into the future. The Hotel building as configured is obsolete in terms of current urban standards, and is situated in a large surface parking lot, contrary to the planning vision for this area. While this parcel would naturally be grandfathered into the new land use/zoning, major additions, or improvements to the structure incompatible with the new planning goals would not likely be approved, leading to a disincentive for reinvestment and ultimately blight conditions. C. Distribution Of Substandard Structures Much of this report has focused on the condition of individual buildings as they relate to requirements identified by Minnesota Statutes, Section 469.174, Subdivision 10 and 10a. It is also important to look at the distribution of substandard buildings throughout the geographic area of the proposed TIF District. FINDING: Buildings meeting the requirements of Minnesota Statutes, Section 469.174, Subdivision 10 and 10a are reasonably distributed compared to all parcels that contain buildings. 16 West 78th Street Renewal and Renovation TIF LHB Project No. 230558.00 Page 11 of 12 Final Report  Diagram 3: Distribution of Substandard Structures Yellow: parcels with buildings. Orange: Structurally Substandard Building Blue: Other Conditions warranting renovation or clearance (Subd. 10a. (1) (iii) 17 West 78th Street Renewal and Renovation TIF LHB Project No. 230558.00 Page 12 of 12 Final Report  Part 5: Team Credentials Michael A. Fischer, AIA, LEED AP - Project Principal/TIF Analyst Michael has 34 years of experience as project principal, project manager, project designer and project architect on planning, urban design, educational, commercial, and governmental projects. He has become an expert on Tax Increment Finance District analysis assisting over 100 cities with strategic planning for TIF Districts. He is an Architectural Principal at LHB and currently leads the Minneapolis office. Michael completed a two-year Bush Fellowship, studying at MIT and Harvard in 1999, earning master’s degrees in City Planning and Real Estate Development from MIT. He has served on more than 50 committees, boards, and community task forces, including a term as a City Council President, Chair of a Metropolitan Planning Organization, and Chair of the Edina Planning Commission. Most recently, he served as a member of the Edina city council and Secretary of the Edina HRA. Michael has also managed and designed several award-winning architectural projects and was one of four architects in the Country to receive the AIA Young Architects Citation in 1997. Phil Fisher – Inspector For 35 years, Phil Fisher worked in the field of Building Operations in Minnesota including White Bear Lake Area Schools. At the University of Minnesota, he earned his Bachelor of Science in Industrial Technology. He is a Certified Playground Safety Inspector, Certified Plant Engineer, and is trained in Minnesota Enterprise Real Properties (MERP) Facility Condition Assessment (FCA). His FCA training was recently applied to the Minnesota Department of Natural Resources Facilities Condition Assessment project involving over 2,000 buildings. Appendices APPENDIX A Property Condition Assessment Summary Sheet APPENDIX B Building Code and Condition Deficiencies Reports APPENDIX C Property Condition Assessment Building Replacement Cost Reports Code Deficiency Cost Reports Photographs 18 APPENDIX A Property Condition Assessment Summary Sheet 19 West 78th Street Renewal and Renovation TIF District Property Condition Assessment Summary SheetTIF Map No.PID # Property AddressImproved or VacantSurvey Method UsedSite Area(S.F.)Coverage Area of Improvements(S.F.)Coverage Percent of ImprovementsCoverageQuantity(S.F.)No. of BuildingsBuildingReplacementCost15% of Replacement CostBuilding Code DeficienciesNo. of Buildings Exceeding 15% CriteriaNo. of buildings determined substandardMeets Subd. 10a. (1) (iii) RequirementsA252830010 570 Market Street Improved Interior/Exterior 39,640 37,658 95.0% 39,640 1 $3,792,114 $568,817 $964,004 1 1 1B251180010 575 West 78th Street Improved Interior/Exterior 23,958 22,520 94.0% 23,958 See Parcel E Note 1C251180020 575 West 78th Street Improved Interior/Exterior 23,086 23,086 100.0% 23,086 See Parcel E Note 1D251190040 N/A Vacant Exterior 1,307 1,307 100.0% 1,307E251190010 591 West 78th Street Improved Interior/Exterior 50,094 47,088 94.0% 50,094 1 $16,449,055 $2,467,358 $2,370,924 0 0 1F251190030 N/A Vacant Exterior 38,332 34,499 90.0% 38,332TOTALS 176,417 176,417 2 1 1 2100.0%Note 1: One continuous building covers Parcels B, C, and EThe Parcel E line contains the full building information 50.0%50.0%M:\23Proj\230558\300 Design\Reports\Final Report\[230558 West 78th Street TIF Summary Sheet.xlsx]Property InfoPercent of other buildings meeting Subd. 10a. (1) (iii) Requirements 100.0%Total Coverage Percent:Percent of buildings exceeding 15 percent code deficiency threshold: Percent of buildings determined substandard: Chanhassen, MinnesotaWest 78th Street Renewal and Renovation TIF DistrictLHB Project Number 230558.00Page 1 of 1Property Condition Assessment Summary Sheet20 APPENDIX B Building Code and Condition Deficiencies Reports 21 West 78th Street TIF District Page 1 of 3 Building Report LHB Project No. 230558.00 Parcel A – 570 Market St, Chanhassen, MN 55317 West 78th Street Renewal and Renovation TIF District Building Code, Condition Deficiency and Context Analysis Report Parcel A Chanhassen Cinema Address: 570 Market Street, Chanhassen, Minnesota 55317 Parcel ID: 252830010 Inspection Date(s) & Time(s): July 27, 2023 10am Inspection Type: Interior and Exterior Summary of Deficiencies: It is our professional opinion that this building is Substandard because: - Substantial renovation is required to correct Conditions found. - Building Code deficiencies total more than 15% of replacement cost, NOT including energy code deficiencies. Estimated Replacement Cost: $3,792,114 Estimated Cost to Correct Building Code Deficiencies: $964,004 Percentage of Replacement Cost for Building Code Deficiencies: 25.4% DEFECTS IN STRUCTURAL ELEMENTS 1. Exterior masonry walls are failing, allowing for water intrusion which is contrary to code. 2. Steel lintels should be protected from rusting per code. 3. Masonry foundation walls are failing allowing for water intrusion which is contrary to code. COMBINATION OF DEFICIENCIES 1. Essential Utilities and Facilities a. There is no code required accessible parking. b. There is no code compliant accessible route into the building. c. There is no code required accessible route to all levels of the building. 2. Light and Ventilation a. The lighting system does not comply with code. b. The HVAC system does not comply with code. 3. Fire Protection/Adequate Egress a. Natural gas meter should be protected per code. b. Interior stairs do not comply with code. c. Damaged flooring material is creating an impediment to emergency egress which is contrary to code. d. The emergency notification system does not comply with code. e. Flammable material is improperly stored which is contrary to code. f. Exterior stairs are damaged creating an impediment to emergency egress which is contrary to code. 22 West 78th Street TIF District Page 2 of 3 Building Report LHB Project No. 230558.00 Parcel A – 570 Market St, Chanhassen, MN 55317 4. Layout and Condition of Interior Partitions/Materials a. The ceiling tile is damaged or missing and should be replaced. b. Mold is present though out the building. c. Interior walls should be repaired and repainted. 5. Exterior Construction a. Exterior walls should be repainted. b. Hollow metal doors are failing and should be replaced. c. Steel railings are rusting and should be repaired or replaced. d. The roofing material has failed, allowing for water intrusion which is contrary to code. e. Exterior caulking has failed, allowing for water intrusion which is contrary to code. DESCRIPTION OF CODE DEFICIENCIES 1. Exterior masonry wall should be repaired or replaced to prevent water intrusion per code. 2. Steel lintels should be protected from rusting per code. 3. Failing masonry foundation walls should be repaired and or replaced to comply with structural integrity per code. 4. Code required accessible parking should be created. 5. A code required accessible route into the building should be created. 6. A code required accessible route to all levels of the building should be created. 7. A code-compliant lighting system should be installed. 8. A code-compliant HVAC system should be installed. 9. The natural gas meter should be protected, per code. 10. Interior stairs should be modified to comply with code. 11. Damaged flooring material should be replaced to create a code required unimpeded means for emergency egress. 12. The emergency notification system should be replaced to comply with code. 13. Flammable material should be stored in a code approved container. 14. Damaged exterior stairs should be repaired to create a code required unimpeded means for emergency egress. 15. Failed roofing material should be replaced to prevent water intrusion per code. 16. Failed exterior joint caulking should be removed and replaced to prevent water intrusion per code. OVERVIEW OF DEFICIENCIES This building has been vacant for several years and is showing severe signs of exterior structural system failure. The exterior concrete masonry units are failing, allowing for water intrusion which is contrary to code. There is no code required accessible parking. The existing accessible ramp does not meet current code. Steel lintels should be protected from rusting to comply with code. A code required accessible route to all levels of the building should be created. The interior stairs do not comply with code. Interior walls should be repaired and repainted. Damaged or missing ceiling tile should be replaced. There is mold throughout the building. The interior flooring is damaged creating an impediment to emergency egress which is contrary to code. The lighting system does not comply with code. The HVAC system does not comply with code. The natural gas meter should be protected per code. The emergency notification system does not comply with code. The exterior concrete stairs are damaged creating an impediment to emergency egress which is contrary to code. Failed roofing material should be replaced to prevent water intrusion per code. Failed exterior joint caulking should be replaced to prevent water intrusion per code. 23 West 78th Street TIF District Page 3 of 3 Building Report LHB Project No. 230558.00 Parcel A – 570 Market St, Chanhassen, MN 55317 ENERGY CODE DEFICIENCIES In addition to the building code deficiencies listed above, the existing building does not comply with the current energy code. These deficiencies are not included in the estimated costs to correct code deficiencies and are not considered in determining whether or not the building is substandard. M:\23Proj\230558\300 Design\Reports\Building Reports\A - 570 Market St Building Report Redevelopment District.docx 24 West 78th Street TIF District Page 1 of 3 Building Report LHB Project No. 230558.00 Parcel E – 591 W 78th St, Chanhassen, MN 55317 West 78th Street Renewal and Renovation TIF District Building Code, Condition Deficiency and Context Analysis Report Parcel E Country Inn and Suites Address: 591 West 78th Street, Chanhassen, Minnesota 55317 Parcel ID: 251190010 Inspection Date(s) & Time(s): July 27, 2023 9am Inspection Type: Interior and Exterior Summary of Deficiencies: It is our professional opinion that this building IS NOT Substandard because: - Substantial renovation IS NOT required to correct Conditions found. - Building Code deficiencies DO NOT total more than 15% of replacement cost, NOT including energy code deficiencies. Estimated Replacement Cost: $16,449,055 Estimated Cost to Correct Building Code Deficiencies: $2,370,924 Percentage of Replacement Cost for Building Code Deficiencies: 14.4% DEFECTS IN STRUCTURAL ELEMENTS 1. Steel lintels should be protected from rusting per code. COMBINATION OF DEFICIENCIES 1. Essential Utilities and Facilities a. No deficiencies observed. 2. Light and Ventilation a. The lighting system does not comply with code. b. The HVAC system does not comply with code. 3. Fire Protection/Adequate Egress a. Floor tile is damaged creating an impediment to emergency egress which is contrary to code. b. Thresholds do not comply with code for maximum height. c. Smoke gaskets on fire rated doors are damaged and will not comply with code. d. Personal hand railings on the exterior are not properly secured and should be repaired. e. Stairs do not comply with code. f. Electrical panels do not have the code required 36-inch clear space. g. The entrance canopy does not have a code required sprinkler system. h. Exterior sidewalks are damaged creating an impediment to emergency egress which is contrary to code. 25 West 78th Street TIF District Page 2 of 3 Building Report LHB Project No. 230558.00 Parcel E – 591 W 78th St, Chanhassen, MN 55317 i. Exterior stairs are damaged creating an impediment to emergency egress which is contrary to code. j. Staff reports that the building sprinkler system is failing, allowing for water intrusion which is contrary to code. k. Staff reports that the building emergency notification system is failing, which requires replacement per code. l. Staff reports that the smoke detectors are failing and should be replaced per code. 4. Layout and Condition of Interior Partitions/Materials a. The ceiling tile is damaged or missing and should be replaced. b. Interior walls should be repaired and repainted. c. The carpet is stained and should be cleaned and or replaced. d. Mold is present within the building. e. Ceramic wall tiles are damaged and should be replaced. f. Ceilings are stained from water damage and should be repaired and repainted. 5. Exterior Construction a. Areas of the exterior walls are compromised, allowing for water intrusion which is contrary to code. b. Exterior control joint caulking is failing, allowing for water intrusion which is contrary to code. c. Exterior wood surfaces should be repainted. d. Staff reports that windows are failing, allowing for water intrusion which is contrary to code. e. Staff reports that the roofing material is failing, allowing for water intrusion which is contrary to code. DESCRIPTION OF CODE DEFICIENCIES 1. Steel lintels should be protected from rusting per code. 2. The lighting system does not comply with code. 3. The HVAC system does not comply with code. 4. Damaged floor tile should be repaired/replaced to create an unimpeded means for emergency egress per code. 5. Thresholds should be modified to comply with code. 6. Smoke gaskets on fire rated doors do not comply with code. 7. Loose hand railings should be properly secured per code. 8. The stairs should be modified to comply with code. 9. A code required 36-inch clear space in front of all electrical panels should be maintained. 10. The entrance canopy does not have a code required sprinkler system. 11. Exterior sidewalks should be repaired to create a code required unimpeded means for emergency egress. 12. Repair existing sprinkler system to comply with code. 13. Install a code compliant emergency notification system. 14. Install code compliant smoke detectors. 15. Repair exterior walls to prevent water intrusion per code. 16. Remove and replace failed exterior caulking to prevent water intrusion per code. 17. Replace existing windows that are failing to prevent water intrusion per code. 18. Replace failing roofing system to prevent water intrusion per code. 26 West 78th Street TIF District Page 3 of 3 Building Report LHB Project No. 230558.00 Parcel E – 591 W 78th St, Chanhassen, MN 55317 OVERVIEW OF DEFICIENCIES This building is currently being operated as a hotel. Steel lintels should be protected from rusting per code. The lighting and HVAC systems do not comply with code. Sidewalks, exterior stairs, and interior floor tile are damaged creating an impediment to emergency egress which is contrary to code. Thresholds should be modified to comply with code. Damaged smoke gaskets on fire rated doors should be repaired to comply with code. Loose hand railing should be properly secured per code. Items in corridors that are obstructing emergency egress should be removed per code. Interior stairs should be modified to comply with code. The entrance canopy should have a code required sprinkler system installed. The building sprinkler system should be repaired to comply with code. A code compliant emergency notification system and smoke detectors should be installed. Repair exterior walls to prevent water intrusion per code. Replace failing window system to prevent water intrusion per code. The failing roofing system should be replaced to prevent water intrusion per code. ENERGY CODE DEFICIENCIES In addition to the building code deficiencies listed above, the existing building does not comply with the current energy code. These deficiencies are not included in the estimated costs to correct code deficiencies and are not considered in determining whether the building is substandard. M:\23Proj\230558\300 Design\Reports\Building Reports\E - 591 W 78th St Building Report Redevelopment District.docx 27 APPENDIX C Property Condition Assessments Building Replacement Cost Reports Code Deficiency Cost Reports Photographs 28 Replacement Cost Report Square Foot Cost Estimate Report Date:8/24/2023 Estimate Name:570 Market Street Building Type:Movie Theater with Concrete Block / Steel Joists Location:CHANHASSEN, MN Story Count:1 Story Height (L.F.):20.00 Floor Area (S.F.):22400 Labor Type:OPN Basement Included:No Data Release:Year 2023 Quarter 3 Cost Per Square Foot:$169.29 Building Cost:$3,792,114.90 Quantity % of Total Cost Per S.F. Cost A Substructure 8.26% $12.15 $272,208.46 A1010 Standard Foundations $4.63 $103,717.00    A10101051560 Foundation wall, CIP, 4' wall height, direct chute, .148 CY/LF, 7.2 PLF,  12" thick                                                       650 $2.93 $65,615.23    A10101102700 Strip footing, concrete, reinforced, load 11.1 KLF, soil bearing capacity  6 KSF, 12" deep x 24" wide 650 $1.62 $36,269.68    A10102107200 Spread footings, 3000 PSI concrete, load 50K, soil bearing capacity 6  KSF, 3' ‐ 0" square x 12" deep 7.47 $0.08 $1,832.09 A1030 Slab on Grade $7.13 $159,768.90    A10301202240 Slab on grade, 4" thick, non industrial, reinforced 22400 $7.13 $159,768.90 A2010 Basement Excavation $0.39 $8,722.56    A20101104560 Excavate and fill, 10,000 SF, 4' deep, sand, gravel, or common earth,  on site storage 22400 $0.39 $8,722.56 B Shell 27.42% $40.37 $904,200.80 B1010 Floor Construction $1.41 $31,600.53    B10102461250 Floor, concrete, slab form, open web bar joist @ 2' OC, on bearing  wall, 25' span, 22.5" deep, 100 PSF superimposed load, 145 PSF total  load 2250 $1.41 $31,600.53 B1020 Roof Construction $13.06 $292,524.29    B10201206500 Roof, steel joists, joist girder, 1.5" 22 ga metal deck, on  columns/bearing wall, 60'x50' bay, 40 PSF superimposed load, 71"  deep, 65 PSF total load 22400 $12.36 $276,950.02    B10201206550 Roof, steel joists, joist girder, 1.5" 22 ga metal deck, on  columns/bearing wall, 60'x50' bay, 40 PSF superimposed load, 71"  deep, 65 PSF total load, add for column 22400 $0.70 $15,574.27 B2010 Exterior Walls $7.13 $159,736.20    B20101116280 Concrete block (CMU) wall, regular weight, 75% solid, 8 x 8 x 16, 4500  PSI, reinforced, vertical #5@32", grouted 10400 $7.13 $159,736.20 B2020 Exterior Windows $8.31 $186,139.98    B20202101250 Aluminum flush tube frame, for 1/4"glass, 1‐3/4"x4", 5'x20' opening,  three intermediate horizontals                                  2600 $3.31 $74,149.92    B20202201400 Glazing panel, insulating, 1" thick units, 2 lites, 1/4" float glass, clear     2600 $5.00 $111,990.06 B2030 Exterior Doors $2.20 $49,237.16    B20301106950 Door, aluminum & glass, with transom, narrow stile, double door,  hardware, 6'‐0" x 10'‐0" opening 1.87 $0.75 $16,703.82    B20302203450 Door, steel 18 gauge, hollow metal, 1 door with frame, no label, 3'‐0"  x 7'‐0" opening 9.33 $1.45 $32,533.34 B3010 Roof Coverings $8.26 $184,962.64    B30101051400 Roofing, asphalt flood coat, gravel, base sheet, 3 plies 15# asphalt felt,  mopped 22400 $4.04 $90,497.34    B30103203090 Insulation, rigid, roof deck, composite with 2" EPS, 1" perlite 22400 $2.72 $60,943.90    B30104201400 Roof edges, aluminum, duranodic, .050" thick, 6" face 650 $1.16 $25,976.18    B30106305100 Gravel stop, aluminum, extruded, 4", mill finish, .050" thick 650 $0.34 $7,545.22 West 78th Street Renewal and Renovation TIF District Costs are derived from a building model with basic components. Scope differences and market conditions can cause costs to vary significantly. West 78th Street TIF District LHB Project No. 230558.00 Page 1 of 3 Replacement Cost Report Parcel A - 570 Market St, Chanhassen, MN 55317 29 C Interiors                                                                   19.33% $28.45 $637,264.72 C1010 Partitions                                                                  $4.23 $94,785.78    C10101045500 Concrete block (CMU) partition, light weight, hollow, 6" thick, no  finish                                                                                                                      8960 $4.23 $94,785.78 C1020 Interior Doors                                                              $1.57 $35,214.61    C10201022600 Door, single leaf, kd steel frame, hollow metal, commercial quality,  flush, 3'‐0" x 7'‐0" x 1‐3/8"                                                                                31.77 $1.57 $35,214.61 C1030 Fittings                                                                    $0.52 $11,586.22    C10301100460 Toilet partitions, cubicles, ceiling hung, stainless steel                               4 $0.45 $10,041.60    C10305100130 Directory boards, outdoor, 36" x 36"                                                             1 $0.07 $1,544.62 C2010 Stair Construction                                                          $3.04 $67,992.96    C20101100760 Stairs, steel, pan tread for conc in‐fill, picket rail,20 risers w/ landing    3.73 $3.04 $67,992.96 C3010 Wall Finishes                                                               $3.47 $77,820.26    C30102202000 2 coats paint on masonry with block filler 10400 $1.78 $39,929.14    C30102300320 Painting, masonry or concrete, latex, brushwork, primer & 2 coats        17920 $1.69 $37,891.12 C3020 Floor Finishes                                                              $6.76 $151,341.98    C30204100160 Carpet, tufted, nylon, roll goods, 12' wide, 36 oz                                        21280 $5.17 $115,731.07    C30204100220 Carpet, padding, add to above, 2.7 density                                                  21280 $1.12 $25,003.36    C30204101720 Tile, ceramic natural clay                                                                                  1120 $0.47 $10,607.55 C3030 Ceiling Finishes                                                            $8.86 $198,522.91    C30302107400 Acoustic ceilings, 3/4"mineral fiber, 12" x 12" tile, concealed 2" bar &  channel grid, suspended support                                                                     22400 $8.86 $198,522.91 D Services                                                                    34.67% $51.03 $1,143,116.52 D1010 Elevators and Lifts                                                         $3.80 $85,088.40    D10101102200 Hydraulic, passenger elevator, 3000 lb, 2 floors, 100 FPM                        1 $3.80 $85,088.40 D2010 Plumbing Fixtures                                                           $14.23 $318,717.14    D20101102080 Water closet, vitreous china, bowl only with flush valve, wall hung        50.77 $9.21 $206,203.20    D20102102000 Urinal, vitreous china, wall hung                                                                     9.52 $0.73 $16,358.64    D20103101600 Lavatory w/trim, vanity top, PE on CI, 19" x 16" oval                                  19.04 $1.50 $33,523.54    D20104404300 Service sink w/trim, PE on CI,wall hung w/rim guard, 22" x 18"               3.17 $0.93 $20,940.59    D20108201880 Water cooler, electric, wall hung, dual height, 14.3 GPH                           9.52 $1.86 $41,691.17 D2020 Domestic Water Distribution                                                 $0.39 $8,705.74    D20202202260 Gas fired water heater, residential, 100< F rise, 30 gal tank, 32 GPH      1.7 $0.39 $8,705.74 D2040 Rain Water Drainage                                                         $0.86 $19,213.44    D20402102120 Roof drain, DWV PVC, 5" diam, 10' high                                                        3.4 $0.48 $10,797.89    D20402102160 Roof drain, DWV PVC, 5" diam, for each additional foot add                    128 $0.38 $8,415.55 D3050 Terminal & Package Units                                                    $12.35 $276,713.92    D30501504440 Rooftop, single zone, air conditioner, schools and colleges, 10,000 SF,  38.33 ton                                                                                                              22400 $12.35 $276,713.92 D4010 Sprinklers                                                                  $5.78 $129,527.46    D40104100620 Wet pipe sprinkler systems, steel, light hazard, 1 floor, 10,000 SF          22400 $4.76 $106,541.79    D40104100700 Wet pipe sprinkler systems, steel, light hazard, each additional floor,  2000 SF                                                                                                                 4480 $1.03 $22,985.67 D4020 Standpipes                                                                  $1.47 $32,951.80    D40203101540 Wet standpipe risers, class III, steel, black, sch 40, 4" diam pipe, 1  floor                                                                                                                       1.87 $1.19 $26,671.40    D40203101560 Wet standpipe risers, class III, steel, black, sch 40, 4" diam pipe,  additional floors                                                                                                  1.87 $0.28 $6,280.40 D5010 Electrical Service/Distribution                                             $1.16 $25,993.87    D50101200320 Overhead service installation, includes breakers, metering, 20' conduit & wire, 3 phase, 4 wire, 120/208 V, 400 A                                                     1 $0.33 $7,303.53    D50102300320 Feeder installation 600 V, including RGS conduit and XHHW wire, 400  A                                                                                                                             100 $0.56 $12,525.40    D50102400200 Switchgear installation, incl switchboard, panels & circuit breaker,  120/208 V, 3 phase, 400 A                                                                                0.5 $0.28 $6,164.94 D5020 Lighting and Branch Wiring                                                  $8.70 $194,855.37    D50201100200 Receptacles incl plate, box, conduit, wire, 2.5 per 1000 SF, .3 watts  per SF                                                                                                                    22400 $2.29 $51,381.12    D50201350200 Miscellaneous power, to .5 watts                                                                   22400 $0.18 $4,110.40    D50201400240 Central air conditioning power, 3 watts                                                        22400 $0.78 $17,412.42    D50202100500 Fluorescent fixtures recess mounted in ceiling, 0.8  watt per SF, 20 FC,  5 fixtures @32 watt per 1000 SF                                                                      22400 $3.87 $86,720.26    D50202901000 Daylight dimming control system, 10 fixtures per 1000 SF                        11200 $1.57 $35,231.17 West 78th Street TIF District LHB Project No. 230558.00 Page 2 of 3 Replacement Cost Report Parcel A - 570 Market St, Chanhassen, MN 55317 30 D5030 Communications and Security                                                 $2.12 $47,558.54    D50309100220 Communication and alarm systems, includes outlets, boxes, conduit  and wire, sound systems, 12 outlets                                                               0.28 $0.33 $7,299.94    D50309100452 Communication and alarm systems, fire detection, addressable, 25  detectors, includes outlets, boxes, conduit and wire                                   1.12 $1.19 $26,752.10    D50309100462 Fire alarm command center, addressable with voice, excl. wire &  conduit                                                                                                                  1 $0.60 $13,506.50 D5090 Other Electrical Systems                                                    $0.17 $3,790.84    D50902100200 Generator sets, w/battery, charger, muffler and transfer switch,  gas/gasoline operated, 3 phase, 4 wire, 277/480 V, 7.5 kW                       2.63 $0.17 $3,790.84 E Equipment & Furnishings                                                     10.33% $15.21 $340,700.72 E1020 Institutional Equipment                                                     $4.26 $95,405.60    E10203100210 Architectural equipment, movie equipment film transport, including  platters & autownd, econ                                                                                  1 $0.34 $7,512.00    E10203100220 Architectural equipment, movie equipment lamphouses, including  rectifiers, xenon, 1000W                                                                                   1 $0.46 $10,386.56    E10203100240 Architectural equipment, movie equipment, projector mechanisms,  35 mm, economy                                                                                                1 $0.66 $14,880.00    E10203200090 Architectural equipment, movie equipment projection screens, rigid in wall, acrylic, 1/4" thick                                                                                       1600 $2.80 $62,627.04 E1090 Other Equipment                                                             $0.00 $0.00 E2010 Fixed Furnishings                                                           $10.95 $245,295.12    E20105100110 Architectural equipment, movie equipment seating, painted steel,  upholstered, economy                                                                                       560 $10.95 $245,295.12 F Special Construction                                                        0.00% $0.00 $0.00 G Building Sitework                                                           0.00% $0.00 $0.00 100% $147.21 $3,297,491.22 15.0% $22.08 $494,623.68 0.0% $0.00 $0.00 0.0% $0.00 $0.00 Total Building Cost $169.29 $3,792,114.90 Contractor Fees (General Conditions,Overhead,Profit) Architectural Fees SubTotal User Fees West 78th Street TIF District LHB Project No. 230558.00 Page 3 of 3 Replacement Cost Report Parcel A - 570 Market St, Chanhassen, MN 55317 31 Code Deficiency Cost Report Parcel A - 570 Market Street, Chanhassen, Minnesota 55317 Building Name or Type Parcel ID 252830010 Chanhassen Cinema Code Related Cost Items Unit Cost Units Unit Quantity Total Accessibility Items Parking Create code required accessible parking 500.00$ Lump 1 500.00$ Accessible Route Install a code approved accessible route into the building 1.00$ Lump 50,000 50,000.00$ Install a code approved accessible route to all levels of the building 3.80$ SF 22,400 85,120.00$ Structural Elements Exterior Masonry Walls Repair failing masonry walls to prevent water intrusion per code 5.00$ SF 22,400 112,000.00$ Steel Lintels Protect steel lintels from rusting per code 500.00$ Lump 1 500.00$ Masonry Foundation Repair failing masonry foundation to prevent water intrusion per code 1.62$ SF 22,400 36,288.00$ Exiting Stairs Modify interior stairs to comply with code 2.00$ SF 22,400 44,800.00$ Repair damaged exterior stairs to create a code compliant means for emergency egress 2,500.00$ Lump 1 2,500.00$ Flooring Material Repair/replace damaged flooring material to create a code required unimpeded means for emergency egress 6.29$ SF 10,000 62,900.00$ Emergency Notification System Install a code compliant emergency notification system 0.60$ SF 22,400 13,440.00$ Fire Protection Natural Gas Meter Protect natural gas meter per code 1,500.00$ Lump 1 1,500.00$ Flammable Material Store flammable material per code 500.00$ Lump 1 500.00$ Exterior Construction Caulking Remove and replace failed caulking to prevent water intrusion per code 0.25$ SF 22,400 5,600.00$ Roof Construction West 78th Street Renewal and Renovation TIF District West 78th Street TIF District LHB Project No. 230558.00 Page 1 of 2 Code Deficiency Cost Report Parcel A - 570 Market St, Chanhassen, MN 55317 32 Code Related Cost Items Unit Cost Units Unit Quantity Total Roofing Material Replace failed roofing material to prevent water intrusion per code 8.26$ SF 22,400 185,024.00$ Mechanical - Electrical Mechancial Install a code compliant HVAC system 12.35$ SF 22,400 276,640.00$ Electrical Install a code compliant lighting system 3.87$ SF 22,400 86,688.00$ Total Code Improvements 964,000$ West 78th Street TIF District LHB Project No. 230558.00 Page 2 of 2 Code Deficiency Cost Report Parcel A - 570 Market St, Chanhassen, MN 55317 33 IMG_9404.JPG IMG_9407.JPG IMG_9410.JPG IMG_9405.JPG IMG_9408.JPG IMG_9411.JPG IMG_9406.JPG IMG_9409.JPG IMG_9412.JPG West 78th Street Renewal and Renovation TIF District | Parcel A 34 IMG_9413.JPG IMG_9416.JPG IMG_9419.JPG IMG_9414.JPG IMG_9417.JPG IMG_9420.JPG IMG_9415.JPG IMG_9418.JPG IMG_9421.JPG West 78th Street Renewal and Renovation TIF District | Parcel A 35 IMG_9422.JPG IMG_9425.JPG IMG_9428.JPG IMG_9423.JPG IMG_9426.JPG IMG_9429.JPG IMG_9424.JPG IMG_9427.JPG IMG_9430.JPG West 78th Street Renewal and Renovation TIF District | Parcel A 36 IMG_9431.JPG IMG_9434.JPG IMG_9437.JPG IMG_9432.JPG IMG_9435.JPG IMG_9438.JPG IMG_9433.JPG IMG_9436.JPG IMG_9439.JPG West 78th Street Renewal and Renovation TIF District | Parcel A 37 IMG_9440.JPG IMG_9443.JPG IMG_9446.JPG IMG_9441.JPG IMG_9444.JPG IMG_9447.JPG IMG_9442.JPG IMG_9445.JPG IMG_9448.JPG West 78th Street Renewal and Renovation TIF District | Parcel A 38 IMG_9449.JPG IMG_9452.JPG IMG_9455.JPG IMG_9450.JPG IMG_9453.JPG IMG_9456.JPG IMG_9451.JPG IMG_9454.JPG IMG_9457.JPG West 78th Street Renewal and Renovation TIF District | Parcel A 39 IMG_9458.JPG IMG_9461.JPG IMG_9464.JPG IMG_9459.JPG IMG_9462.JPG IMG_9465.JPG IMG_9460.JPG IMG_9463.JPG IMG_9466.JPG West 78th Street Renewal and Renovation TIF District | Parcel A 40 IMG_9467.JPG IMG_9470.JPG IMG_9473.JPG IMG_9468.JPG IMG_9471.JPG IMG_9474.JPG IMG_9469.JPG IMG_9472.JPG IMG_9475.JPG West 78th Street Renewal and Renovation TIF District | Parcel A 41 IMG_9476.JPG IMG_9547.JPG IMG_9550.JPG IMG_9477.JPG IMG_9548.JPG IMG_9551.JPG IMG_9478.JPG IMG_9549.JPG IMG_9552.JPG West 78th Street Renewal and Renovation TIF District | Parcel A 42 IMG_9553.JPG IMG_9556.JPG IMG_9559.JPG IMG_9554.JPG IMG_9557.JPG IMG_9560.JPG IMG_9555.JPG IMG_9558.JPG IMG_9561.JPG West 78th Street Renewal and Renovation TIF District | Parcel A 43 IMG_9562.JPG IMG_9565.JPG IMG_9568.JPG IMG_9563.JPG IMG_9566.JPG IMG_9569.JPG IMG_9564.JPG IMG_9567.JPG IMG_9570.JPG West 78th Street Renewal and Renovation TIF District | Parcel A 44 IMG_9571.JPG IMG_9574.JPG IMG_9577.JPG IMG_9572.JPG IMG_9575.JPG IMG_9573.JPG IMG_9576.JPG West 78th Street Renewal and Renovation TIF District | Parcel A 45 Square Foot Cost Estimate Report Date:8/24/2023 Estimate Name:591 West 78th Street Building Type:Motel, 2‐3 Story with Brick Veneer / Wood Frame Location:CHANHASSEN, MN Story Count:3 Story Height (L.F.):9.00 Floor Area (S.F.):84267 Labor Type:OPN Basement Included:No Data Release:Year 2023 Quarter 3 Cost Per Square Foot:$195.20 Building Cost:$16,449,055.28 Quantity % of Total Cost Per S.F. Cost A Substructure 3.15% $5.34 $450,258.01 A1010 Standard Foundations $2.84 $238,974.23    A10101051560 Foundation wall, CIP, 4' wall height, direct chute, .148 CY/LF, 7.2 PLF,  12" thick                                                       1400 $1.68 $141,325.10    A10101102700 Strip footing, concrete, reinforced, load 11.1 KLF, soil bearing capacity  6 KSF, 12" deep x 24" wide 1750 $1.16 $97,649.13 A1030 Slab on Grade $2.38 $200,345.92    A10301202240 Slab on grade, 4" thick, non industrial, reinforced 28089 $2.38 $200,345.92 A2010 Basement Excavation $0.13 $10,937.86    A20101104560 Excavate and fill, 10,000 SF, 4' deep, sand, gravel, or common earth,  on site storage 28089 $0.13 $10,937.86 B Shell 25.06% $42.54 $3,584,918.37 B1010 Floor Construction $4.78 $402,614.24    B10102613750 Floor, wood joist, 2 x 12 @16" O.C., 1/2" CDX subfloor 56178 $4.78 $402,614.24 B1020 Roof Construction $3.87 $325,863.86    B10201027200 Wood roof, truss, 4/12 slope, 24" O.C., 44' to 60' span 28089 $3.87 $325,863.86 B2010 Exterior Walls $12.43 $1,047,147.22    B20101291400 Brick veneer wall, standard face, 2x6 studs @ 16" back‐up, running  bond 32130 $12.43 $1,047,147.22 B2020 Exterior Windows $7.36 $620,218.62    B20201066850 Windows, aluminum, sliding, insulated glass, 5' x 3'378 $7.36 $620,218.62 B2030 Exterior Doors $11.92 $1,004,408.35    B20301106950 Door, aluminum & glass, with transom, narrow stile, double door,  hardware, 6'‐0" x 10'‐0" opening 3.44 $0.37 $30,778.01    B20301107300 Door, aluminum & glass, with transom, bronze finish, hardware, 3'‐0"  x 10'‐0" opening 13.76 $0.74 $62,465.58    B20302203450 Door, steel 18 gauge, hollow metal, 1 door with frame, no label, 3'‐0"  x 7'‐0" opening 261.4 $10.81 $911,164.76 B3010 Roof Coverings $2.19 $184,666.08    B30101401100 Asphalt roofing, strip shingles, inorganic, Class A, 4" slope, 210‐235  lbs/SQ 29493.45 $0.91 $77,026.57    B30103203090 Insulation, rigid, roof deck, composite with 2" EPS, 1" perlite 29493.45 $0.95 $80,243.12    B30104300040 Flashing, aluminum, no backing sides, .019"     1400 $0.20 $17,252.37    B30106100050 Gutters, box, aluminum, .027" thick, 5", enameled finish 700 $0.09 $7,262.56    B30106200100 Downspout, aluminum, rectangular, 2" x 3", embossed mill finish,  .020" thick 464.33 $0.03 $2,881.46 C Interiors 31.86% $54.09 $4,557,592.81 C1010 Partitions $22.41 $1,888,513.85    C10101045020 Concrete block (CMU) partition, light weight, hollow, 4" thick, gyp  plaster, 2 sides                                                 96305.14 $20.11 $1,694,682.56    C10107101001 1/2" fire rated gypsum board, taped & finished, painted on metal  furring 32130 $2.30 $193,831.29 C1020 Interior Doors $11.33 $954,984.67    C10201022510 Door, single leaf, wood frame, 3'‐0" x 7'‐0" x 1‐3/8", birch, hollow core 1203.81 $11.33 $954,984.67 West 78th Street Renewal and Renovation TIF District Replacement Cost Report Costs are derived from a building model with basic components. Scope differences and market conditions can cause costs to vary significantly. West 78th Street TIF District LHB Project No. 230558.00 Page 1 of 3 Replacement Cost Report Parcel E - 591 W 78th St, Chanhassen, MN 55317 46 C2010 Stair Construction                                                          $3.73 $314,304.90    C20101100740 Stairs, steel, pan tread for conc in‐fill, picket rail,16 risers w/ landing    20.64 $3.73 $314,304.90 C3010 Wall Finishes                                                               $4.00 $337,482.89    C30102300140 Painting, interior on plaster and drywall, walls & ceilings, roller work,  primer & 2 coats                                                                                                 173349.26 $1.99 $167,481.39    C30102301940 Ceramic tile, thin set, 4‐1/4" x 4‐1/4"                                                            19261.03 $2.02 $170,001.50 C3020 Floor Finishes                                                              $7.04 $593,416.26    C30204100160 Carpet, tufted, nylon, roll goods, 12' wide, 36 oz                                        71626.95 $4.62 $389,542.45    C30204100220 Carpet, padding, add to above, 2.7 density                                                  71626.95 $1.00 $84,159.52    C30204101720 Tile, ceramic natural clay                                                                                  12640.05 $1.42 $119,714.29 C3030 Ceiling Finishes                                                            $5.56 $468,890.24    C30301104800 Gypsum board ceilings, 1/2" fire rated gypsum board, painted and  textured finish,1" x 3" wood, 16" OC furring, wood support                      84267 $5.56 $468,890.24 D Services                                                                    38.68% $65.65 $5,531,937.93 D1010 Elevators and Lifts                                                         $5.17 $435,816.54    D10101109150 Hydraulic passenger elevator, 4000 lb., 3 floor, 9' story height, 125  FPM 3.44 $5.17 $435,816.54 D2010 Plumbing Fixtures                                                           $33.11 $2,790,382.20    D20101101880 Water closet, vitreous china, tank type, wall hung, close coupled 2  piece                                                                                                                      298.03 $11.05 $931,395.98    D20102102000 Urinal, vitreous china, wall hung                                                                     3.13 $0.06 $5,378.28    D20103101560 Lavatory w/trim, vanity top, PE on CI, 20" x 18"                                          298.03 $7.22 $608,771.03    D20104101800 Kitchen sink w/trim, countertop, PE on CI, 32" x 21" double bowl          6.24 $0.16 $13,470.83    D20104404300 Service sink w/trim, PE on CI,wall hung w/rim guard, 22" x 18"               8.51 $0.67 $56,174.58    D20105102080 Bathtub, recessed, PE on CI, mat bottom, 5' long                                        295.11 $13.70 $1,154,604.08    D20107101840 Shower, stall, fiberglass 1 piece, three walls, 36" square                           3.13 $0.08 $6,880.50    D20108201880 Water cooler, electric, wall hung, dual height, 14.3 GPH                           3.13 $0.16 $13,706.92 D2020 Domestic Water Distribution                                                 $0.71 $59,849.08    D20202502140 Gas fired water heater, commercial, 100< F rise, 300 MBH input, 278  GPH                                                                                                                        3.63 $0.71 $59,849.08 D3050 Terminal & Package Units                                                    $8.84 $745,171.58    D30502700220 3/4 ton, thru wall, heating. & cooling units 180.57 $8.84 $745,171.58 D4010 Sprinklers                                                                  $4.09 $344,737.73    D40104100620 Wet pipe sprinkler systems, steel, light hazard, 1 floor, 10,000 SF          28650.78 $1.62 $136,272.56    D40104100740 Wet pipe sprinkler systems, steel, light hazard, each additional floor,  10,000 SF                                                                                                              55616.22 $2.47 $208,465.17 D4020 Standpipes                                                                  $0.42 $34,986.89    D40203101540 Wet standpipe risers, class III, steel, black, sch 40, 4" diam pipe, 1  floor                                                                                                                       1.72 $0.29 $24,572.00    D40203101560 Wet standpipe risers, class III, steel, black, sch 40, 4" diam pipe,  additional floors                                                                                                  3.1 $0.12 $10,414.89 D5010 Electrical Service/Distribution                                             $1.26 $106,297.94    D50101200400 Overhead service installation, includes breakers, metering, 20' conduit & wire, 3 phase, 4 wire, 120/208 V, 800 A                                                     1.25 $0.29 $24,291.38    D50102300400 Feeder installation 600 V, including RGS conduit and XHHW wire, 800  A                                                                                                                             200 $0.71 $59,604.60    D50102400280 Switchgear installation, incl switchboard, panels & circuit breaker,  120/208 V, 3 phase, 800 A                                                                                1.2 $0.27 $22,401.96 D5020 Lighting and Branch Wiring                                                  $9.78 $823,984.42    D50201100560 Receptacles incl plate, box, conduit, wire, 10 per 1000 SF, 1.2 W per  SF, with transformer                                                                                           84267 $4.60 $387,550.67    D50201300360 Wall switches, 5.0 per 1000 SF                                                                        84267 $1.51 $127,576.03    D50201350200 Miscellaneous power, to .5 watts                                                                   84267 $0.18 $15,463.00    D50201452080 Motor installation, three phase, 460 V, 15 HP motor size                         2 $0.07 $5,796.50    D50202100200 Fluorescent fixtures recess mounted in ceiling, 1 watt per SF, 20 FC, 5  fixtures @40 watts per 1000 SF                                                                       84267 $3.41 $287,598.22 D5030 Communications and Security                                                 $2.14 $180,209.44    D50309100456 Communication and alarm systems, fire detection, addressable, 100  detectors, includes outlets, boxes, conduit and wire                                   1.81 $1.86 $156,981.84    D50309100462 Fire alarm command center, addressable with voice, excl. wire &  conduit                                                                                                                  1.72 $0.28 $23,227.60 D5090 Other Electrical Systems                                                    $0.12 $10,502.11    D50902100200 Generator sets, w/battery, charger, muffler and transfer switch,  gas/gasoline operated, 3 phase, 4 wire, 277/480 V, 7.5 kW                       7.29 $0.12 $10,502.11 West 78th Street TIF District LHB Project No. 230558.00 Page 2 of 3 Replacement Cost Report Parcel E - 591 W 78 th St, Chanhassen, MN 55317 47 E Equipment & Furnishings                                                     0.16% $0.28 $23,527.21 E1010 Commercial Equipment                                                        $0.28 $23,527.21    E10106100110 Architectural equipment, laundry equipment dryers, gas fired, com,  30 lb capacity, single                                                                                          3.44 $0.09 $7,264.78    E10106100170 Architectural equipment, laundry equipment, washers, commercial,  coin operated, deluxe                                                                                        3.44 $0.19 $16,262.43 E1090 Other Equipment                                                             $0.00 $0.00 F Special Construction                                                        0.00% $0.00 $0.00 G Building Sitework                                                           1.09% $1.84 $155,292.00 G2040 Site Development                                                            $1.84 $155,292.00    G20409204600 Swimming pool, motel class, concrete sides, tile finish, 28' x 60'             1 $1.84 $155,292.00 100% $169.74 $14,303,526.33 15.0% $25.46 $2,145,528.95 0.0% $0.00 $0.00 0.0% $0.00 $0.00 Total Building Cost $195.20 $16,449,055.28 Contractor Fees (General Conditions,Overhead,Profit) Architectural Fees SubTotal User Fees West 78th Street TIF District LHB Project No. 230558.00 Page 3 of 3 Replacement Cost Report Parcel E - 591 W 78 th St, Chanhassen, MN 55317 48 Code Deficiency Cost Report Parcel E - 591 West 78th Street, Chanhassen, Minnesota 55317 Building Name or Type Parcel ID 251190010 Country Inn and Suites Code Related Cost Items Unit Cost Units Unit Quantity Total Accessibility Items *No Deficiencies Observed*-$ Structural Elements Steel Lintels Protect steel lintels from rusting per code 1,000.00$ Lump 1 1,000.00$ Exiting Concrete Sidewalks Repair damaged concrete sidewalks to create an unimpeded means for emergency egress per code 3,500.00$ Lump 1 3,500.00$ Concrete Stairs Repair damaged concrete stairs to create an unimpeded means for emergency egress per code 1,500.00$ Lump 1 1,500.00$ Floor Tile Repair damaged floor tile to create an unimpeded means for emergency egress 1,000.00$ Lump 1 1,000.00$ Handrails Repair loose handrails to create an unimpeded means for emergency egress 500.00$ Lump 1 500.00$ Interior Stairs Modify stairs to comply with code 0.73$ SF 84,267 61,514.91$ Emergency Notification System Install a code compliant emergency notification system 0.28$ SF 84,267 23,594.76$ Fire Protection Circuit Breaker Boxes Maintain a code required 36-inch clear space in front of electrical circuit boxes 250.00$ Lump 1 250.00$ Entrance Canopy Install a code required sprinkler in entrance canopy 4.09$ SF 1,400 5,726.00$ Building Sprinkler System Repair existing sprinkler system to comply with code 2.25$ SF 84,267 189,600.75$ Smoke Detectors Install code compliant smoke detectors 1.86$ SF 84,267 156,736.62$ Fire Doors Replace damaged smoke gaskets on fire rated doors 500.00$ Lump 1 500.00$ West 78th Street Renewal and Renovation TIF District West 78th Street TIF District LHB Project No. 230558.00 Page 1 of 2 Code Deficiency Cost Report Parcel E - 591 W 78th St, Chanhassen, MN 55317 49 Code Related Cost Items Unit Cost Units Unit Quantity Total Exterior Construction Exterior Walls Repair failing exterior walls to prevent water intrusion per code 1.00$ SF 84,267 84,267.00$ Exterior Caulking Replace failed caulking to prevent water intrusion per code 0.05$ SF 84,267 4,213.35$ Windows Replaced failed windows to prevent water intrusion per code 7.36$ SF 84,267 620,205.12$ Roof Construction Roofing Material Replace failed roofing material to prevent water intrusion per code 2.19$ SF 84,267 184,544.73$ Mechanical - Electrical Mechanical Install a code compliant HVAC system 8.84$ SF 84,267 744,920.28$ Electrical Install a code compliant lighting system 3.41$ SF 84,267 287,350.47$ Total Code Improvements 2,370,924$ West 78th Street TIF District LHB Project No. 230558.00 Page 2 of 2 Code Deficiency Cost Report Parcel E - 591 W 78th St, Chanhassen, MN 55317 50 IMG_9390.JPG IMG_9393.JPG IMG_9396.JPG IMG_9391.JPG IMG_9394.JPG IMG_9397.JPG IMG_9392.JPG IMG_9395.JPG IMG_9398.JPG West 78th Street Renewal and Renovation TIF District | Parcel E 51 IMG_9399.JPG IMG_9402.JPG IMG_9480.JPG IMG_9400.JPG IMG_9403.JPG IMG_9481.JPG IMG_9401.JPG IMG_9479.JPG IMG_9482.JPG West 78th Street Renewal and Renovation TIF District | Parcel E 52 IMG_9483.JPG IMG_9486.JPG IMG_9489.JPG IMG_9484.JPG IMG_9487.JPG IMG_9490.JPG IMG_9485.JPG IMG_9488.JPG IMG_9491.JPG West 78th Street Renewal and Renovation TIF District | Parcel E 53 IMG_9492.JPG IMG_9495.JPG IMG_9498.JPG IMG_9493.JPG IMG_9496.JPG IMG_9499.JPG IMG_9494.JPG IMG_9497.JPG IMG_9500.JPG West 78th Street Renewal and Renovation TIF District | Parcel E 54 IMG_9501.JPG IMG_9504.JPG IMG_9507.JPG IMG_9502.JPG IMG_9505.JPG IMG_9508.JPG IMG_9503.JPG IMG_9506.JPG IMG_9509.JPG West 78th Street Renewal and Renovation TIF District | Parcel E 55 IMG_9510.JPG IMG_9513.JPG IMG_9516.JPG IMG_9511.JPG IMG_9514.JPG IMG_9517.JPG IMG_9512.JPG IMG_9515.JPG IMG_9518.JPG West 78th Street Renewal and Renovation TIF District | Parcel E 56 IMG_9519.JPG IMG_9522.JPG IMG_9525.JPG IMG_9520.JPG IMG_9523.JPG IMG_9526.JPG IMG_9521.JPG IMG_9524.JPG IMG_9527.JPG West 78th Street Renewal and Renovation TIF District | Parcel E 57 IMG_9528.JPG IMG_9531.JPG IMG_9534.JPG IMG_9529.JPG IMG_9532.JPG IMG_9535.JPG IMG_9530.JPG IMG_9533.JPG IMG_9536.JPG West 78th Street Renewal and Renovation TIF District | Parcel E 58 IMG_9537.JPG IMG_9540.JPG IMG_9543.JPG IMG_9538.JPG IMG_9541.JPG IMG_9544.JPG IMG_9539.JPG IMG_9542.JPG IMG_9545.JPG West 78th Street Renewal and Renovation TIF District | Parcel E 59 IMG_9546.JPG IMG_9580.JPG IMG_9583.JPG IMG_9578.JPG IMG_9581.JPG IMG_9584.JPG IMG_9579.JPG IMG_9582.JPG IMG_9585.JPG West 78th Street Renewal and Renovation TIF District | Parcel E 60 IMG_9586.JPG IMG_9587.JPG IMG_9588.JPG West 78th Street Renewal and Renovation TIF District | Parcel E 61 Prepared by: 701 Washington Avenue North, Suite 200, Minneapolis, MN 55401 LHBcorp.com LHB Project No. 230558.00 62 With this application, please submit a formal letter requesting assistance and stating the need for assistance. An escrow fee will be required to pay all legal and financial service fees associated with the application process. Any unused portion of this fee will be returned to the applicant if the project is not approved or if the applicant decides not to proceed. The application is not considered complete until the application escrow has been received. Business Name:_________________________________________________________ Address:_______________________________________________________________ City, State, Zip: _________________________________________________________ Contact Person:____________________________ Title: ________________________ Telephone:________________________________Email:________________________ Parent Company or DBA (if applicable): _______________________________________ Address:_______________________________________________________________ City, State, Zip: _________________________________________________________ Business to be listed as primary on legal documents:____________________________ Consultant Name:_______________________________________________________ Contact Name:______________________ Title: ______________________________ Address:______________________________________________________________ City, State, Zip: ________________________________________________________ Phone:________________________________ Email: _________________________ Type of Subsidy Requested ☐Tax Increment Financing (TIF) ☐ Tax Abatement ☐ Other:___________________ Type of TIF: ☐ Economic Development ☐ Redevelopment ☐ Housing CITY OF CHANHASSEN Business Subsidy Application Applicant Information Consultant Information Subsidy & Owner Information 63 City of Chanhassen, P.O. Box 147, 7700 Market Blvd, Chanhassen, MN 55317 • www.chanhassenmn.gov • 952.227.1100 Ownership Structure & Financial History ☐Corporation ☐ Partnership ☐ LLC ☐ Proprietorship ☐ Other _________________ Proprietorship, partners, officers, directors, and holders of outstanding stocks of 10 percent or more of business ownership must be accounted for in the table below. Name Title % of Ownership % % % % Have there ever been judgments or injunctions against the business or owners? ☐ Yes ☐ No If yes, describe: ______________________________________ Is there pending litigation involved in the business? ☐ Yes ☐ No If yes, describe: ______________________________________ Has the business or the owners of the business ever filed for bankruptcy? ☐ Yes ☐ No If yes, describe:______________________________________ Has the business or the owners defaulted on a loan commitment? ☐ Yes ☐ No If yes, describe: ______________________________________ Is the business or owner(s) currently delinquent on property taxes in Chanhassen? ☐ Yes ☐ No Is the business or owner(s) currently delinquent on utility bills in Chanhassen? ☐Yes ☐No Are you engaged in international trade? ☐Yes ☐ No If awarded, what is the intended use of funds? If possible, please provide preliminary cost estimates._________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ Project Information 64 City of Chanhassen, P.O. Box 147, 7700 Market Blvd, Chanhassen, MN 55317 • www.chanhassenmn.gov • 952.227.1100 Project Type: ☐ Expansion ☐ Startup Do you have facilities in other locations? ☐ Yes ☐ No If yes, please list:________________________________________________________ Will any jobs be relocated from another Minnesota site? ☐ Yes ☐ No If yes, which location(s) will the jobs be located from? ___________________________ *Provide a statement within the attachment section as to why the project cannot be completed at its current location/facility. What is the company’s current number of Full Time Equivalent employees in Chanhassen? _______ *Full Time Equivalent (FTE) is based on total annual hours of 2,080. What is the company’s current number of FTE employees in Minnesota? ______ Number of new FTE jobs to be created within two (2) years in Chanhassen? ______ Number of new FTE jobs to be created within five (5) years in Chanhassen? ______ *Job numbers will be used to determine eligibility for scoring and for job creation commitments. What is the hourly base wage of the lowest-paid job that will be created? ______ How many jobs earning a base wage of 200% of the State Minimum Wage or higher are anticipated to be created? ________ *Wage & Job Creation. A project receiving a business subsidy must have demonstrated that one-third (33%) of the full-time equivalent positions created or retained within the city will be paying at least 200% of the State of MN Minimum Wage in effect at the time the business subsidy is awarded. What is the average base wage of all the jobs created? _____________ Wage Levels per Hour Number of Permanent FTE Positions at this Wage Level Hourly Value of Health Insurance Benefits (Health & Dental) Hourly Value of Non- Health Insurance Benefits (Life, Profit Sharing, Bonuses, Retirement, etc.) Less than $14.50 $14.50 - $14.99 $15.00 - $16.99 $17.00 - $18.99 $19.00 - $20.99 $21.00 - $22.99 $23.00 - $24.99 $25.00 - $26.99 $27.00 - $28.99 $29.00 - $30.99 $31.00 and Over Wage/Benefit Table Jobs & Wages Housing and Redevelopment TIF applicants may skip this section. 65 City of Chanhassen, P.O. Box 147, 7700 Market Blvd, Chanhassen, MN 55317 • www.chanhassenmn.gov • 952.227.1100 PID: ________________________________________________________________________ Total Size of Property: __________________________________________________________ Total Size of Facility: ___________________________________________________________ Commercial/Industrial Breakdown, in square feet Manufacturing/Assembly/Processing Research Laboratory Office Warehouse Other Residential Breakdown Total number of 1-bedroom units: ____ Total Square feet per 1-bedroom unit: ____ Total number of 2-bedroom units: ____ Total square feet per 2-bedroom unit: ____ Total number of 3-bedroom units: ____ Total square feet per 3-bedroom unit: ____ Total number of 4-bedroom units: ____ Total square feet per 4-bedroom unit: ____ Total square feet of other: _______ Will the facility be leased or owned: ☐ Leased ☐ Owned Are there any environmental risks associated with the site, building, or the business itself? ☐ Yes ☐ No Have the state environmental review requirements been met, if applicable? ☐Yes ☐No Note: 20% of equity is required. Local Government Bank Equity DEED Other Total Property Acquisition Site Improvement New Construction Renovation of an Existing Building Purchase of Machinery & Equipment Public Infrastructure Other Total Project Costs Property Information Estimated Sources and Uses 66 City of Chanhassen, P.O. Box 147, 7700 Market Blvd, Chanhassen, MN 55317 • www.chanhassenmn.gov • 952.227.1100 Task Estimated Completion Date Commitment of all Funds Start of Construction Purchase of Equipment Complete Construction Begin Operations Attach the following information with the application. Application is not considered Complete until all documents have been received. o Provide a brief narrative of the company. What is the business' competitive position in the marketplace? Briefly describe the past and present operations of the business and/or events leading up to its creation. Include when business was established and any change in controlling ownership within the last five years. Does the marketing strategy support the planned expansion or start-up? Is public assistance necessary for this project? If so, why will the project not proceed without public assistance? o Site information, including site plan, renderings of the proposed project, narrative description of the location, scope, size, and type of development. o Planning and zoning analysis: Does the project conform to the current zoning? Are any variances needed? If so, please identify and explain. o Studies and analysis in support of project: o Preliminary economic analysis showing existing taxes, future taxes, and source and use of funds. o Pro forma analysis of the project or market that have been completed. o Market feasibility analysis. o Preliminary economic analysis of the company’s financials may be required and would need to include review of the following information: three years historical financial information, including balance sheets, profit and loss statements, and cash flow statements. o Payment of $12,000 escrow fee. Estimated Project Timetable Application Checklist 67 City of Chanhassen, P.O. Box 147, 7700 Market Blvd, Chanhassen, MN 55317 • www.chanhassenmn.gov • 952.227.1100 NOTICE TO THE COMPANY: DATA PRACTICES ACT The information that you supply in your application to the City of Chanhassen EDA ("city") will be used to assess your eligibility for financial assistance. The city will not be able to process your application without this information. The Minnesota Government Data Practices Act (Minnesota Statutes, Chapter 13) governs whether the information that you are providing to the city is public or private. Financial assistance is provided for the project, the information submitted in connection with your application will become public, except for those items protected under Minnesota Statutes, Section 13.59, Subdivision 3(b) or Section 13.591, Subdivision 2. I have read the above statement and I agree to supply the information to the city with full knowledge of the matters contained in this notice. I certify that the information submitted in connection with the application is true and accurate. __________________________________________________ _________________ Signature of Applicant or Authorized Representative Date Office Use Only Received by: Date Received: Fee paid: 68 Two Carlson Parkway N | Suite 400 Plymouth, MN 55447 763.285.8808 roerscompanies.com Roers Companies Roers Companies is a full-service real estate, property management, and construction firm based in Plymouth, Minnesota. Founded in 2012 by Brian and Kent Roers, the firm started with an entrepreneurial spirit and passion with projects in the Bakken oil fields of North Dakota. Since then, the entrepreneurial and hands on nature has enabled the company to grow to 250 employees with offices in Minnesota, Texas, and Florida and expanded further with in-house development, construction, and property management. These functions allow the company to control all aspects of the project through volatile markets and enable us and our investors to own and operate its projects in the long term. This vertical integration along with a very diverse and deep pool of high-net-worth investors has allowed Roers Companies to differentiate itself in the marketplace and deliver strong projects to the communities it is within. The company has remained under majority ownership of Brian and Kent since inception. Market Analysis The marketing strategy supports the additional units in this market for three reasons. First, Roers Companies developed and owns Venue Apartments, a mixed-use development adjacent to the subject properties. Since its inception, the property has remained consistently leased, has strong tenant retention, and strong tenant satisfaction. Second, it is our understanding that the market for commercial space in Chanhassen is very strong sporting historically low vacancy rates with strong demand for national and local retailers. We have experienced a strong amount of interest in the potential of future commercial space. Third, the City’s vision for the evolving downtown with the new zoning, new City Hall building, and the desire to break up the super blocks, all contribute to the vision of this corner. These three pieces of information allow Roers to feel very confident in the marketing plan for this project. Public Assistance The project is requesting public assistance in the form of tax increment financing for three reasons. First, the project is a prominent corner located at the center of downtown Chanhassen and is the acquisition of a dated and partially blighted, operating hotel making the acquisition price above what would be considered market for a similar project. Second, there are significant sitework costs above and beyond what a normal multi-family and commercial project would require, which includes the construction of a new public road. Finally, the retail rents are being offered below market to attract local tenants in order to maximize job creation in the community. Because of these three factors, the project would not proceed but for the use of public assistance in the form of tax increment financing. If public assistance was not provided, the project would not meet a market rate of return and therefore there would not be equity available to fund the project. 69 Two Carlson Parkway N | Suite 400 Plymouth, MN 55447 763.285.8808 roerscompanies.com Site Information The project is located at the Southeast corner of Market Boulevard and West 78th Street. The project will consist of 2 stories of underground parking which will be for residents and retail users, sectioned off accordingly. The project will be 5 stories tall with 306 total market rate housing units. Both buildings will be highly amenitized with a pool deck, fitness center, community space, dog wash and dog run, work from home spaces, and roof top terraces. Central to the ground floor circulation are the retail spaces which are carefully designed in collaboration with various community stakeholders and potential tenants with the goal of maximizing the activity, jobs, and public benefit of the site. Roers Companies has partnered with Kimley Horn, who is also working on the city’s public infrastructure project, to ensure a seamless transition with the projects likely occurring at the same time. In addition, Roers has partnered with ESG architecture who has designed many of the most prominent urban apartment buildings in the twin cities to bring an urban mixed-use project to downtown Chanhassen with high quality materials, glazing, and keen urban design. Zoning The project will comply with the “CBD” zoning guidelines which are currently being implemented and have been reviewed concurrently with the city’s implementation to ensure cohesion. Specifically, the project has been inspired by Sec 20-731 of the code stating, “The intent of the “CBD District is to provide for downtown business development supporting a strong central business district while enhancing the overall character of the community in conformance with downtown redevelopment plan, goals and objectives.” This project will provide smaller blocks with sidewalks promoting walkability, hidden parking structures, varied facades with minimal setbacks from the street, active mixed uses with commercial space targeting restaurants and other similar users and will be constructed with high quality classic materials to contribute to a desirable downtown destination. The design team is working closely with Staff on whether or not variances will be required to enable the plans set forth and goals of the project to come to fruition. Financial Analysis Please refer to the attached documentation. 70 Two Carlson Parkway N | Suite 400 Plymouth, MN 55447 763.285.8808 roerscompanies.com 71 VENUE APARTMENTS ALDI CHANHASSEN STATION CHANHASSEN DINNER THEATERS 974 977 964 RETAIL PARKING RESIDENTIAL RESTAURANT 960 973 FUTURE LOREDO DRIVE EXTENSIONRESIDENTIALROOF ROOFMARKET BLVDW 78TH ST MARKET ST LOBBY RETAIL RESIDENT PARKING RETAIL LOBBY PET EXERCISE PLAN NORTH Scale:1" = 80'-0" Market Blvd & W 78th St DISTRICT SITE PLAN 8/24/2023 Chanhassen, MN 72 974 964 29,681 SF RETAIL PARKING 6,696 SF RESIDENTIAL 4,595 SF RESTAURANT MARKET BLVDW 78TH ST 3,034 SF LOBBY 7,928 SF RETAIL 12,585 SF RESIDENT PARKING 3,151 SF RETAIL 2 MP1.9 ALDI VENUE APARTMENTS JIMMY JOHN'S FUTURE LAREDO STREET EXTENSION22,108 SF RESIDENTIAL 6.06%1 MP1.9 TOWN HOME TOWN HOME TOWN HOME TOWN HOME TOWN HOME 2,085 SF TERRACE 1,071 SF BOH 7,323 SF AMENITY PET EXERCISE PLAN NORTH Scale:1" = 60'-0" Market Blvd & W 78th St STREET LEVEL PLAN 8/24/2023 Chanhassen, MN 73 37,897 SF RESIDENTIAL 2 MP1.9 1 MP1.9 28,678 SF RESIDENTIAL 1,485 SF AMENITY 5,196 SF AMENITY PLAN NORTH Scale:1" = 60'-0" Market Blvd & W 78th St LEVEL 2 FLOOR PLAN 8/24/2023 Chanhassen, MN 74 2 MP1.9 1 MP1.9 44,578 SF RESIDENTIAL 28,678 SF RESIDENTIAL PLAN NORTH Scale:1" = 60'-0" Market Blvd & W 78th St LEVEL 3 PLAN (LEVELS 4 & 5 SIMILAR) 8/24/2023 Chanhassen, MN 75 2 MP1.9 1 MP1.9 37,584 SF RESIDENTIAL PLAN NORTH Scale:1" = 60'-0" Market Blvd & W 78th St LEVEL 6 PLAN 8/24/2023 Chanhassen, MN 76 57,755 SF PARKING 36,066 SF PARKING EXISTING RETAINING WALL TO BE REPLACED IN KIND EXISTING RETAINING WALL TO BE REMOVED - FOUNDATION WALL EXPOSED RETAIL ABOVE (UNEXCAVATED) MOVE IN 2 MP1.9 VENUE APARTMENTS PARKING 4,375 SF RESIDENTIAL 1 MP1.9 6.01%6.01% 513 SF PLAN NORTH Scale:1" = 60'-0" Market Blvd & W 78th St MINUS 1 LEVEL PLAN 8/24/2023 Chanhassen, MN 77 2 MP1.9 45,518 SF PARKING 1 MP1.9 ELEC PLAN NORTH Scale:1" = 60'-0" Market Blvd & W 78th St MINUS 2 LEVEL PLAN 8/24/2023 Chanhassen, MN 78 LEVEL 1 100' - 0" LEVEL 2 115' - 0" LEVEL 3 126' - 8" LEVEL 4 137' - 4" LEVEL 5 148' - 0" LEVEL 6 158' - 8" ROOF LEVEL 169' - 4" MINUS 1 LEVEL 88' - 8" MINUS 2 LEVEL 77' - 4" 6.06% 6.01%10' - 8"10' - 8"10' - 8"10' - 8"11' - 8"15' - 0"11' - 4"11' - 4"LEVEL 1 100' - 0" LEVEL 2 115' - 0" LEVEL 3 126' - 8" LEVEL 4 137' - 4" LEVEL 5 148' - 0" LEVEL 6 158' - 8" ROOF LEVEL 169' - 4" MINUS 1 LEVEL 88' - 8" MINUS 2 LEVEL 77' - 4"10' - 8"10' - 8"10' - 8"10' - 8"11' - 8"15' - 0"11' - 4"11' - 4"Scale:1" = 30'-0" Market Blvd & W 78th St SITE SECTIONS 8/24/2023 Chanhassen, MN EAST/WEST SECTION THROUGH WEST BUILDING NORTH/SOUTH SECTION THROUGH WEST BUILDING 79 CITY OF CHANHASSEN CARVER AND HENNEPIN COUNTIES, MINNESOTA ORDINANCE NO. _____ AN ORDINANCE AMENDING CHAPTER 20 CHANHASSEN CITY CODE “CBD” CENTRAL BUSINESS DISTRICT THE CITY COUNCIL OF THE CITY OF CHANHASSEN, MINNESOTA ORDAINS: SECTION 1. Chapter 20, Article 20-XVIII of the City Code, City of Chanhassen, Minnesota, is hereby amended to read as follows: Sec 20-731 Intent The intent of the “CBD District is to provide for downtown business development supporting a strong central business district while enhancing the overall character of the community in conformance with downtown redevelopment plan, goals and objectives. Sec 20-732 Permitted Uses The following uses are permitted in the “CBD” District: (a) Restaurant (b) Entertainment (c) Commercial Services (d) Commercial Retail (e) Commercial Office (f) Brewery with Taproom producing less than 3,500 barrels subject to section 20-969 (g) Brew pub subject to section 20-968 (h) Hotels (i) Multi-family housing 1) When a multi-family housing use has frontage on West 78th Street, a portion of the building shall incorporate a restaurant, entertainment, commercial service, commercial retail, brewery, brew pub, or microdistillery use. (j) Microdistillery with cocktail room subject to section 20-967 (k) Public parking ramp (l) Post office (m) Library Sec 20-733 Accessory Uses The following are accessory uses in the “CBD” District: (a) Parking lots and ramps (b) Signs (c) Temporary outdoor sales and events subject to section 20-964 (d) Accessory solar energy systems subject to section 20-1093 80 (e) Utility Service Sec 20-734 Conditional Uses The following uses are conditional uses in the “CBD” District: (a) Brewery operated in conjunction with taproom producing over 3,500 barrels per year. (b) Day care center Sec 20-735 Interim Uses (a) Farmers Markets Sec 20-736 Lot Requirements The following minimum requirements shall be observed in the “CBD” District: (a) There is no minimum lot area, lot frontage, or lot depth. (b) There is no maximum lot coverage. Sec 20-737 Setbacks and Height Restrictions The following performance standards shall be observed in the “CBD” District: (a) Setback and height standards: Build To Zones Side Yard Setback Height (ft) CBD Character Areas Primary Roadways Secondary Roadways Total Stories Ground Story Upper Stories 78th Street, Market Blvd, Great Plains Blvd Laredo Dr, Chan View Rd, Kerber Blvd, Market St Min Min Max Min Max Min Max Downtown Mixed Use 0’ – 15’ 0’ – 30’ 0’ 1 6* 14 18 9 12 Downtown West 5’ – 25’ 10’ – 30’ 0’ 1 6* 12 15 9 12 *If building more than 3 stories and adjacent to property zoned as Residential Single Family (RSF) then the setbacks applicable for the RSF zoning district shall apply. (b) The Central Business District (CBD) shall be broken down into the following character areas: 1) Downtown Mixed Use – high quality architecture with ground level retail along w. 78th Street, upper level residential or office, buildings towards the street, parking in the rear, pedestrian focused. 2) Downtown West – high quality architecture, commercial and retail focus with more traditional suburban development pattern with parking to the side of buildings with pedestrian connections from streets to storefronts. 3) Civic/Institutional – high quality architecture with public or institutional uses serving as anchor destinations and attractions. 4) Central Business District character areas diagram: 81 SECTION 2. This ordinance shall be effective immediately upon its passage and publication. PASSED AND ADOPTED this 25th day of September, 2023, by the City Council of the City of Chanhassen, Minnesota Laurie Hokkanen, City Manager Elise Ryan, Mayor (Published in the Chanhassen Villager on ______________________________) 82 2 Carlson Parkway N | Suite 400 Plymouth, MN 55447 763.285.8808 roerscompanies.com HOLD: Project Financials 83 Litigation Summary I. Litigation Matters Roers Management Inc. (Settled) In December 2020, Roers Management Inc. (“RMI”)—a North Dakota contracting and construction business operated by a separate branch of the Roers family—initiated a lawsuit claiming that Roers Companies’ use of “Roers Companies” infringed RMI’s rights in the trademark ROERS BUILDING SUCCESS. RMI also claimed ownership (and infringement) of the trademarks in “Roers” and “Roers Companies.” Roers Companies disputes these claims and presented evidence that Roers Companies (not RMI) owns the trademark ROERS COMPANIES. The case proceeded through discovery. The parties then settled their dispute on non-monetary terms. Under the terms of the parties’ settlement, RMI acknowledged Roers Companies’ ownership and rights in the ROERS COMPANIES trademark, and RMI agreed to refrain from using ROERS COMPANIES in any capacity. For its part, Roers Companies agreed not to use ROERS, alone, in certain real estate settings. Roers Companies also agreed to certain, limited restrictions on future changes to its Roers Companies logo. All active litigation between the parties has been dismissed, with each party bearing its owns costs and attorney fees. Doboszenski v. Core Living (Settled) Former employee filed discrimination-related claims regarding failure to accommodate her disability, reprisal and discriminatory discharge. Core Living LLC (now known as Roers Residential LLC), a subsidiary of Roers Companies LLC, denied the allegations in their entirety and disputed the claims through litigation. Without admitting any liability, Roers Residential LLC (F/K/A Core Living LLC) agreed to a private settlement with the plaintiff and the case has been dismissed. Robinson v. Core Living LLC (Settled) Former employee filed discrimination-related claims with the Wisconsin Equal Rights Division and the EEOC. Core Living LLC (now known as Roers Residential LLC), a subsidiary of Roers Companies LLC, denied the allegations in their entirety and disputed the claims through litigation. Without admitting any liability, Roers Residential LLC (F/K/A Core Living LLC) agreed to a private settlement with the plaintiff and the case has been dismissed. The Pines at Rapid v. HDC (Settled) An affiliate of Roers was the plaintiff in a matter seeking to recover damages from a general contractor in connection with a settling issue affecting a multifamily housing project owned by the affiliate in South Dakota. The parties reached a private settlement and the matter was dismissed. Tioga Apartments v. HDC et. al (Ongoing) An affiliate of Roers is the plaintiff in a matter seeking to recover damages from a general contractor, architect and engineer in connection with a settling issue affecting a multifamily housing project owned by the affiliate in North Dakota. Litigation is ongoing and it is anticipated that alternative dispute resolution, such as mediation, will be pursued by the parties. Bowen v. Community Within the Corridor Limited Partnership (Ongoing) There is pending litigation involving the East Block of The Community Within the Corridor, a historic redevelopment/affordable housing project located in Milwaukee, WI, which was co-developed and is co- owned by an affiliate of Roers and a local, third-party developer, Scott Crawford Inc. As part of the redevelopment, the developers undertook substantial environmental remediation of the project site and 84 committed to certain testing and mitigation protocols in connection with the presence of trichloroethylene (TCE), a carcinogen, on the property. The lawsuit alleges that CWC failed to disclose to tenants the presence of TCE on the site and misrepresented the project as a safe, new housing facility. Roers and Scott Crawford Inc., neither of whom are named in the lawsuit, have been working diligently and continuously on behalf of Community Within the Corridor Limited Partnership to remedy the underlying technical/environmental issues impacting the property, and have provided extensive support to those residents affected by these issues. The parties have reached a preliminary agreement to settle the litigation, without any admission of liability by CWC with respect to the allegations; this agreement is subject to court approval and that process is ongoing. In the unlikely event the proposed settlement is not approved, an adverse outcome of the litigation would not have a material impact on Roers’ financial or organizational health, nor affect its ability to undertake future development projects. Gregory T. Dunham, on behalf of himself and all others similarly situated v. Roers Companies (Ongoing) (Fourth Judicial District Court, Hennepin County, Minnesota): This lawsuit was served on the company on October 3, 2023. The plaintiff, a former maintenance technician, alleges claims under the Minnesota Fair Labor Standards Act, the Minnesota Payment of Wages Act, and Minnesota common law, seeking to recover alleged unpaid straight time and overtime wages and related damages, stemming from allegations that he and others like him worked in an on-call capacity and were not properly paid for all time that they were on-call. Plaintiff Dunham seeks to represent a proposed class of all individuals employed by the company in an on-call capacity and paid on an hourly basis in the past three years. No such class has been certified and the company has not yet had to respond to the Complaint, but the company denies the allegations in their entirety and intends to vigorously defend the case. At this early stage in the case, while we cannot predict any outcome, the company anticipates having significant defenses to liability and does not believe the scope of any potential class will exceed approximately 30 individuals. Tart and Smith v. Roers Companies (Dismissed). Lawsuit related to a security deposit dispute with a former tenant, for an amount at issue under $1500. The matter was resolved and dismissed. II. Regulatory Matters In October 2022, Brian Roers, a principal of Roers Companies LLC, received notice of a complaint filed with the Board of Realty Regulation, a division of the Montana Department of Labor & Industry. Mr. Roers timely responded to the complaint as required by the notice, and has not received any further information or inquiries from the Board since that time. In January 2023, Kent Roers, a principal of Roers Companies LLC, received notice of an investigation and request for information from the Certified Financial Planner Board of Standards, Inc.. Mr. Roers timely responded to the complaint as required by the notice, and has not received any further information or inquiries from the Board since that time. In 2023, Roers Residential LLC, a subsidiary of Roers Companies LLC, executed a settlement and consent order with the Iowa Real Estate Commission, relating to an allegation that the company failed to timely notify the Commission of a previous entity name change in connection with its real estate brokerage license. The settlement agreement did not include any admission of guilt or wrongdoing on the part of Roers Residential LLC. 85 86