Loading...
Letter 9-20-04 CITY OF CHANHASSEN ¡ 100 Market Boulevard PO Box 147 ',:t':1ssen, MN 55317 Administration Phone 952227.1100 ~5n271110 Building Inspections Phone 952227.1180 9~,22271190 énoineering ;')2.227.1160 Fax 952.227.1170 r:G~nce '7.1140 , 1110 P~rk R. l1p,creation n.1120 ¡ 1110 Recreation Center Roulevard .1400 .1404 Planning & Natur]1 Resources 2227.1130 1I¿227.1110 Public Works 1591 Park Road ¡)none 952.227.1300 fax. 952.227.1310 Senior Center 952.227.1125 352227.1110 Web Site WWW.CI chanhassen.mnus September 20, 2004 Mr. Nathan B. Franzen Plowshares Development, Inc. 1851 Lake Drive West, Suite 550 Chanhassen, MN 55317 Re: Pinehurst - Planning Case No. 04-36 Dear Mr. Franzen: Staff has reviewed the submittal for the proposed development of Pinehurst. Based on this review, we find that the submittal is incomplete. The following must be submitted in order for the City to adequately review the project: 1. Show a full-size grading plan meeting all the requirements of the ordinance including a 60-foot right-of-way, a 31-foot street section, 60-foot radius cul- de-sac and 7 percent street grade (similar to the concept plan in the narrative). 2. Include a 1"=60' scale pre- and post-development drainage area map. 3. On the grading plan, call out the typical housing types (WO, La, R) and show the proposed front and rear building elevations. 4. On the grading plan, show existing typography within 100 feet of the project property line. 5. Provide a breakdown of the quantity oftrees by individual species. (Note: there are no quantities for ornamental trees). 6. Verify that Lot 4, Block 1 meets the 100-foot lot width at the building setback line. 7. Verify that all lots on cul-de-sacs meet the minimum 90-foot lot width at the building setback line. 8. Wetland setbacks for AglUrban wetlands are a minimum of 56.5 feet from the wetland edge. The minimum wetland buffer is 16.5 feet. Revise the development data (sheet 3 of 11) and wetland setback lines for Lots 5, 6 and 11, Block 1 to show this setback. 9. Include a 20-foot wide drainage easement over the storm water pipe running between Lots 9 and 10 and Lots 14 and 15, Block 1, and Lots 10 and 11 and Lots 13 and 14, Block 2. The City of Chanhassen . A growing community with clean lakes, quality schools, a charming downtown, Ihriving businesses, winding trails, and beautiful parks A great place 10 live, work, and play. Mr. Nathan B. Franzen September 20, 2004 Page 2 In order to remain on the October 19, 2004 Planning Commission agenda, you will need to have the above revisions to me by Wednesday, September 22, 2004. If you have any questions or need additional information, please contact me at (952) 227- 1131 or bgenerous@ci.chanhassen.mn.us. Robert Generous, AICP Senior Planner ec: Kate Aanenson, Community Development Director Matt Saam, Assistant City Engineer g:\plan\2004 planning cases\04-36 - pinehurst\incomplete letter,doc