Loading...
Survey Received 5-2-05 GRAPHIC SCALE I 11 20 I ~~ - ( IN FEET X869.9 PROPOSED ELEVATIONS: TOP OF FOUNDATION 879.0 GARAGE FLOOR 878. 6 LOW FLOOR 870.3 BENCHMARK 869.1 SHARRATT DESIGN ADVANCE SURVEYING & ENGINEERING CO. 5300 S. Hwy. No. 101 Minnetonka, MN 55345 Phone (952) 474 7964 Fax (952) 474 8267 050064 24/116/23 40 20 PROPOSED RET. WALL, BOTTOM 870.2 £ END, 870.1 WEST END, TOP AS SHOWN (f SURVEY FOR: SHARRATT DESIGN SURVEYED: February 23. 2005 X870.9 X869.2 / ::::::;:. ClîY OF CHANHASSEN RECEIVED MAY (j 2 2005 CI-IANHASSEN PLANNING DEPT 864.8 PROPOSED SIL T FENCE [J [J 54.07 r:tï..-- ¡ . => Top of Iron 869. ~ ! X869.0 '" : ~ , ' , I' \ . ..: 869.0X s x......869.3 N 89"25'52" t --128.92-- 871.9 <;)) .S 'b ::::: <1> <1> :0. ':::: C) 873.4 'b ¡:: <;))~ ·S <1> :t;-Q 8~ '1 o r-- to - - ~ --:-\ 870.1 '/ X OLe X870. .6 871 (j _iiJ íiilf7 "1 4 --126. IO- N 88:37'56" . /(:¡ Jve ' /f -LL ,,: ./~u ~/.' ~.: ,m X871.8 ,x , I e · BIrch ~ ~ ~~ ~ I ~ ~ I ~. ~~i] ~ ~. ~ ~ I ~ " Existing ¢= IS February 24, 2005 LEGAL DESCRIPTION: That part of Government Lot 3, Section 24, Township 116 North, Range 23 West of the 5th Principle Meridian, described as follows: Commencing at the Northwest comer of said Government Lot 3; thence on an assumed bearing of South 0 degrees 25 minutes 00 seconds East, along the West line of said lot; a distance of 1293.86 feet; thence North 89 degrees 22 minutes 14 seconds East a distance of 16.00 feet; thence South 0 degrees 00 minutes 58 seconds East a distance of249.38 feet; thence North 89 degrees 58 minutes 00 seconds East a distance of 49.60 feet; thence North 0 degrees 03 minutes 00 seconds East a distance of 247.87 feet; thence North 89 degrees 34 minutes 42 seconds East a distance of 714.51 feet; thence North 20 degrees 20 minutes 00 seconds East a distance of 304.42 feet; thence North 14 degrees 46 minutes 05 seconds East a distance of 470.07 feet; thence North 13 degrees 17 minutes 09 seconds East a distance of 11.86 feet; thence North 44 degrees 24 minutes 55 seconds East a distance of 64.01 feet to the intersection with a line bearing North 13 degrees 17 minutes 09 seconds East from the Northwest comer of Lot 2, "Shore Acres", according to the recorded plat thereof; thence North 13 degrees 17 minutes 09 seconds East a distance of 156.08 feet; thence North 7 degrees 45 minutes 54 seconds East a distance of 113.96 feet to the point of beginning of the land to be described; thence North 7 degrees 45 minutes 54 seconds East a distance of 13.32 feet; thence on a bearing of West a distance of 9.47 feet; thence North 16 degrees 40 minutes 00 seconds East a distance of60.65 feet; thence North 7 degrees 45 minutes 54 seconds East, along a line passing through a point on the North line of said Government Lot 3 distant 1145.24 feet East from the Northwest comer of said Government Lot 3, a distance of 22.58 feet; thence on a bearing of East about 158 feet to the shoreline of Lake Riley; thence Southerly along said shoreline to its intersection with a line bearing South 88 degrees 10 minutes 02 seconds East from the point of beginning; thence North 88 degrees 10 minutes 02 seconds West about 145 feet to the point of beginning. DRAFTED: The boundaries of the premises are marked by judicial landmarks set pursuant to Torrens Case No. T -684 as shown on the plat of survey on file in the office of the Clerk of Court. ~ ~ ....) ø;:> ~ '?? LIMITATIONS: The scope of our services for this job is as follows: 1. Showing the length and direction of boundary lines of the legal description which you furnished. 2. Showing the location of existing improvements we deemed important. 3. Setting new monuments or verifying existing monuments to mark the comers of the property. 4. Showing existing spot elevations necessary to show elevation differences on the site. 5. While we show a proposed location for this home, we are not as familiar with your house plans as you and your architect and/or builder are. Check our proposed location and siting of the home and yard grades carefully to see that they match your plans before construction begins. Also, we are not as familiar with local codes as the local building official and zoning official in this community are. Be sure to show this survey to these officials, or any other officials that may have jurisdiction over the home and its siting, and obtain their approvals before beginning construction. 6. We have provided a benchmark for your use in determining elevations for construction on this site, use that benchmark and nothing else for that purpose. Check the elevation of at least one other feature shown to verify your elevations. 0<'<9" Þ<,c9 ~74.4 x X874.9 STANDARD SYMBOLS & CONVENTIONS: " . " Denotes 1/2" ID pipe with plastic plug bearing State License Number 9235, set, unless otherwise noted. Proposed elevations are shown with a box around them, while existing elevations are shown without a box. Arrows indicate the proposed flow of storm water on the site. PROPOSED RE T. WALL, TOP MA TCH 0.3 BELOW DRIVE GRADE. BO TTOM AS SHOWN @~~ SHEET 871.8 ~t i?0QI- 8.79..7 1 PROPOSED NEW CONSTRUCTION OF THB COOPER/ WALKER HOME © COPYRICH