Loading...
Approval Letter to Hoagberg 02-27-2015Chanhassen is a Community for Life - Providing for Today and Planning for Tomorrow February 27, 2015 CITY OF CHMNSEN Michael Hoagberg Fax: 952.227.1110 17550 Hemlock Avenue 7700 Market Boulevard Lakeville, MN 55044 PO Box 147 Chanhassen, MN 55317 Re: Mission Hills Senior Living —Planning Case 2015-01 Chanhassen is a Community for Life - Providing for Today and Planning for Tomorrow Dear Mr. Hoagberg: Administration Phone: 952.227.1100 Fax: 952.227.1110 This letter is to formally notify you that on February 23, 2015, the Chanhassen City Council adopted the following motions: Building Inspections Phone: 952.227.1180 1. PLANNED UNIT DEVELOPMENT AMENDMENT Fax: 952.227.1190 Engineering g g "The City Council approves the Planned Unit Development amendment in the Phone: 952.227.1160 d h di f Mi ttaaceordinance or Mission Hs to allow High Density Hills i ll g Use on the site and set Fax: 952.227.1170 standards for the structures as shown below (amendments are shown in bold and highlighted in gray) with the following conditions, and adoption of the attached Finance Findings of Fact. Phone: 952.227.1140 Fax: 952.227.1110 1. The site must comply with the DNR Shoreland Rules. Park & Recreation Phone. 952.227.1120 2. The site shall cornp 1 y with the following standards: Fax: 952.227.1110 Mission Hills Zoning Standards Recreation Center 2310 Coulter Boulevard a. Intent Phone: 952.227.1400 Fax: 952.227.1404 The purpose of this zone is to create a PUD mixed density Planning & housing zone. The use of the PUD zone is to allow for more flexible design standards Natural Resources while creating a higher quality and more sensitive proposal. All utilities es are required Phone: 952.227.1130 to be placed underground. Each structure proposed for development shall proceed Fax: 952.227.1110 through site plan review based on the development standards outlined below. Except eP as modified by the Mission Hills standards below, the mixed density housing Public Works development shall comply with the requirements of the R-8, Mixed Medium Density District. Except as modified by the Mission Hills standards below, +Up �.effi,�. Phone: 952.227.1300 Fax- 952.227.1310 i) • Lot 1, Bloch 1, Mission Hills 31d Addition shall comply with the R-12, High. Density Senior Center District. Phone: 952.227.1125 Fax: 952.227.1110 b. Permitted Uses Chanhassen is a Community for Life - Providing for Today and Planning for Tomorrow Mr. Michael Hoagberg February 27, 2015 Page 2 -t>�-eo i'.] a-eT-tLi Q di QU� ^t. The permitted uses within the development shall include the following: 0 Single Family Residential Medium Density Residential 0 High Density Residential C. Setbacks In the PUD standards, the building setback for commercial is 50 feet from any public right-of- way. The ee,.Y.,-Y,High Density parking setback shall be 35 feet from any public right-of- way and/or interior property line. There shall be a buffer separating the residential portion from the er- High Density portion of the site. This buffer shall be in the form of a berm and landscaping. The following setbacks shall be observed: * Setbacks shall be established pursuant to section 20-505 of Chanhassen City Code. d. Development Standards Tabulation Box Minimum Lot Size multi -family units: Mission Hills: As approved on October 24, 1994 in the Plat of Mission Hills; Mission Hills Villas, A Condominium, Common Interest Community No. 8, 9th Supplemental filed April 10, 1996; Mission Hills Villas, A Condominium, Common Interest Community No. 8, 10th Supplemental filed April 10, 1996; Mission Hills Villas, A Condominium, Common Interest Community No. 8, 11 PhSupplemental filed May 7, 1996; and Mission Hills Villas, A Condominium, Common Interest Community No. 8, 12th Supplemental filed May 20, 1996; Mission Hills 2nd Addition: Area: 2,100 square feet Width: 46 feet Depth: 47 feet Mission Hills 311 Addition: Area: 376,358.4 square feet Width: 480 feet G:\PLAN\2015 Planning Cases\2015-01 Mission Hills Senior Living\Approval letter Prelim Plat PUD and Site Plan.doc Residential Medium Residential Commercial Street High Density Density Parking Parking Building Setback* Building Setback Setback* Setback Highway 101 * 50 ft. 20 ft. Highway 212 * 50 ft. 20 ft. West 86th Street * 30 ft. 20 ft. Interior Lot Lines 0 ft. (from commercial) 0 ft. 0 ft. 0 ft. (from commercial) 50 ft. (from residential) 35 ft. (from residential) * Setbacks shall be established pursuant to section 20-505 of Chanhassen City Code. d. Development Standards Tabulation Box Minimum Lot Size multi -family units: Mission Hills: As approved on October 24, 1994 in the Plat of Mission Hills; Mission Hills Villas, A Condominium, Common Interest Community No. 8, 9th Supplemental filed April 10, 1996; Mission Hills Villas, A Condominium, Common Interest Community No. 8, 10th Supplemental filed April 10, 1996; Mission Hills Villas, A Condominium, Common Interest Community No. 8, 11 PhSupplemental filed May 7, 1996; and Mission Hills Villas, A Condominium, Common Interest Community No. 8, 12th Supplemental filed May 20, 1996; Mission Hills 2nd Addition: Area: 2,100 square feet Width: 46 feet Depth: 47 feet Mission Hills 311 Addition: Area: 376,358.4 square feet Width: 480 feet G:\PLAN\2015 Planning Cases\2015-01 Mission Hills Senior Living\Approval letter Prelim Plat PUD and Site Plan.doc Mr. Michael Hoagberg February 27, 2015 Page 3 Depth: 620 feet BLOCKE US Net Lot Area A ea D Hard Surface Coverage Q44tint, :7=1 Mission Hills 3" Addition 152 Multi -Family Units 8.64 acres 17.5 50% Block 1, Mission Hills 138 Multi -Family Units 18 acres 7.66 37% Block 4, Mission Hills 56 Multi -Family Units 8.92 acres 6.28 43.2% ! ®+_�.. x._ s • a.. 1N. -I aWe wi ai w7 w. w. •�... • • s r. a_ r ®_. • r i �a r a .w. •. ! • i ! ! • i • • w 111 ! ! • • t • � _ r• ! ... . ._... RESIDENTIAL 1. Building exterior material shall be a combination of pre -painted 5 -inch aluminum siding and brick. 2. Arched transoms and soffit returns shall be used over the entries of the one-story units and horizontal transom windows over the 2 story windows. Introduce some variation among the buildings through the shape of windows, adding louvers, shifting entry ways, and adding dormers. 3. Colors used shall be earth tones such as soft gray, creamy white, pearl gray, shell white, etc. 4. Each unit shall have a minimum of one over -story tree within its front yard. G:\PLAN\2015 Planning Cases\2015-01 Mission Hills Senior Living\Approval letter Prelim Plat PUD and Site Plan.doc Mr. Michael Hoagberg February 27, 2015 Page 4 5. All units shall have access onto an interior street and not West 86th Street. 6. The apartment building located on Lot 1, Bloch 1, Mission Hills 3rd Addition shall: a. Have a pronounced entrance. b. Ensure that all foundation walls are screened by landscaping or retaining walls. c. Have materials which include masonry, painted siding, and exterior finish and insulation system (E.I.F.S.) and the structures will have sloped shingle roofs. All elevations that can be viewed by the public have received equal attention. e. Site Landscaping and Screening The planting plans prepared for the site are intended to create a strong sense of street tree plantings using over -story deciduous trees such as Summit Ash, Linden, and Sugar Maple. Highways 101 and 212 will be buffered with a combination of over -story evergreen trees and ornamental deciduous trees. The outdoor private living areas will be buffered with the use of evergreen trees. The wetland will be highlighted with the introduction of native wetland species. In addition, to adhere to the higher quality of development as spelled out in the PUD zone, all loading areas shall be screened. Each lot for development shall submit a separate landscaping plan as a part of the site plan review process. Berms of 2 to 3 feet high shall be added along the Highway 101 and 212 right-of-way. These berms shall be seeded and/or sodded and bushes and trees shall be planted on them. All disturbed areas within the single family lots shall be seeded and/or sodded. Two trees with a minimum of a 21/2 inch caliper shall be planted within the front yard setback. These two trees shall consist of one over -story evergreen tree and one ornamental deciduous tree. 1. All open spaces and non -parking lot surfaces (outlot) shall be landscaped, or covered with plantings and/or lawn material. 2. Outdoor storage is prohibited. 3. Loading areas shall be screened from public rights-of-way. Wing wall may be required where deemed appropriate. 4. The Outlot shall be seeded and maintained in a weed -free condition in all areas proposed for future development. f. Signage One monument sign along Great Plains Boulevard shall be permitted for Lot 1, Block 1, Mission Hills 3rd Addition. ' ixXAIL ee G:\PLAN\2015 Planning Cases\2015-01 Mission Hills Senior Living\Approval letter Prelim Plat PUD and Site Plan.doc Mr. Michael Hoagberg February 27, 2015 Page 5 1 • .Monument signage shall be subject to the monument standards in the sign ordinance. 2. Wall signs are permitted on no more than two street frontages. The total of each wall - mounted sign display area shall not exceed 24 square feet. 3. All signs require a separate permit. 4. The signage will have consistency throughout the development and shall tie the building materials to be consistent with the signs. Signs shall be an architectural feature, they shall not be solely mounted on a pole of a foundation. 5. Consistency in signage shall relate to color, size, materials, and heights. 6. No illuminated signs within Lot 1, Block 1, Mission Mills 3rd AdditiothQ n ay be viewed from the residential section of the PUD. 7. Only back -lit individual letter signs are permitted. 8. Individual letters may not exceed three feet in height. 9. Only the name and logo of the business occupying the unit will be permitted on the sign. RESIDENTIAL One monument identification sign shall be permitted for the residential development. The sign may not exceed 24 square feet in area and 5 feet in height. g. Lighting 1. All light fixtures shall be shielded high-pressure sodium or LED fixtures. Light level for site lighting shall be no more than one-half foot candle at the property line. This does not apply to street lighting. The maximum height of a residential street light shall not exceed 15 feet. Light fixtures within the -eget Lot 1, Block 1, Mission Hills Yd Addition shall not exceed 2 5 feet. 2. Glare, whether direct or reflected, as differentiated from general illumination shall not be visible beyond the limits of the site from which it originates. 3. Lights shall be on a photoelectric cell to turn them on and off automatically as activated by yearly conditions. 2. SUBDIVISION G:\PLAN\2015 Planning Cases\2015-01 Mission Hills Senior Living\Approval letter Prelim Plat PUD and Site Plan.doc Mr. Michael Hoagberg February 27, 2015 Page 6 "The City Council approves the preliminary plat to replat Outlot E, Mission Hills into Lot 1, Block 1, Mission Hills 3rd Addition, as shown in plans dated received December 22, 2014, including the attached Findings of Fact and Recommendation, subject to the following conditions: Park and Trail Conditions 1. Full park fees in lieu of additional parkland dedication and/or trail construction shall be collected as a condition of approval for Lot 1, Block 1, Mission Hills 3rd Addition. The park fees will be collected in full at the rate in force upon final plat submission and approval. Based upon the current residential park fee rates of $3,800 per apartment dwelling and $5,000 per twin home dwelling, the total park fees will be $599,200. Engineering Conditions: 1. The estimated Surface Water Utility fees are $108,921.60. These shall be due with the final plat. 2. The applicant must prepare an operations and maintenance manual that provides for the protection and preservation of the stormwater best management practices (BMPs) to provide for the designed water quality benefit in perpetuity. 3. The applicant must enter into a maintenance agreement with the City and record that agreement against the property." 3. SITE PLAN APPROVAL "The City Council approves the site plan consisting of a 134 -unit senior housing apartment and nine twin homes, Planning Case 2015-01 as shown in plans dated received January 29, 2015, and including the attached Findings of Fact and Recommendation, subject to the following conditions: Environmental Resource Conditions.- 1. onditions: 1. The applicant shall submit a revised landscape plan for approval. The revised plan shall incorporate increased plantings of evergreens and ornamentals along Highway 101 to provide additional screening for the twin homes at the north end of the project site in order to meet minimum bufferyard requirements. Building Official Conditions: 1. The building plans must be prepared and signed by design professionals licensed in the State of Minnesota. A "Code Record" is required (Code Record schematic plans may be same scale as architectural). For "Code Record" information go to MN Department of Labor and Industry website: http://www.dli.mn.gov/CCLD/PlanConstruction.gM. 2. Buildings must be protected with automatic fire suppression systems. 3. An accessible route must be provided to buildings, parking facilities, public transportation stops and all common use facilities. G:\PLAN\2015 Planning Cases\2015-01 Mission Hills Senior Living\Approval letter Prelim Plat PUD and Site Plan.doc Mr. Michael Ho agb erg February 27, 2015 Page 7 4. Parking areas, including parking garages, must be provided with accessible parking spaces dispersed among the various building entrances. 5. Accessible dwelling units must be provided in accordance with Minnesota State Building Code Chapter 1341. 6. The building owner and/or their representatives should meet with the Inspections Division to discuss plan review and permit procedures (in particular, type of construction and allowable area issues must be addressed). Fire Marshal Conditions 1. A three-foot clear space must be maintained around fire hydrants. 2. "No Parking Fire Lane" signs and yellow painted curbing will be required. Contact Fire Marshal for specifics. 3. Street names are required for the main road entering the project and the loop road serving the twin homes. Street signs shall be installed prior to building construction. Proposed street names must be submitted to Chanhassen Fire Marshal and Chanhassen Building Official for review and approval. 4. Fire hydrants shall be installed and made serviceable prior to combustible construction. 5. Prior to combustible construction fire apparatus access roads capable of supporting the weight of fire apparatus shall be made serviceable. 6. In lieu of a fire lane to the back side of the building, additional fire protection features shall be provided, including but not limited to Class 1 standpipes installeder Fire Department p p requirements. 7. Provide to Chanhassen Fire Marshal radius turn dimensions for accessing the building. The concern is the center islands for getting fire apparatus to the front doors. Engineering Conditions: 1. The grading plan must show a spot elevation between the two buildings near Infiltration Basin No. 5, to show that water will flow away from both structures. 2. Proposed grades at the northwest corner of the western parking lot must be revised so as not to exceed a 3:1 slope. 3. The following materials are prohibited for retaining wall construction: smooth face, poured - in -place concrete (stamped or patterned is acceptable), masonry, railroad ties and timber. 4. Walls taller than six feet shall not be constructed with boulder rock. 5. Any wall taller than four feet must be designed by a professional engineer licensed in the State of Minnesota. G:\PLAN\2015 Planning Cases\2015-01 Mission Hills Senior Living\Approval letter Prelim Plat PUD and Site Plan.doc Mr. Michael Hoagberg February 27, 2015 Page 8 6. If a wall is taller than six feet, a fence or other barrier would be required to provide separation from any drive or walkway within 10 feet. 7. The top and bottom wall elevation must be labeled on the southwestern retaining wall. 8. The plans must show names for these streets. 9. The developer's engineer must submit documentation that the street pavement meets a 7 -ton design. 10. The plan set shall include turn movements for a fire truck to navigate the medians for entry access to the main building. 11. The developer shall incorporate the recommendations from the traffic study into their plan set. 12. The parking lot aisles must be a minimum of 26 feet wide. 13. Pedestrian ramps shall meet ADA requirements. 14. All water main and sanitary sewer main constructed in this project shall be privately owned and maintained and must meet the city's requirements for public utilities. 15. This parcel has paid the city for one water and sanitary service hook-up. All additional units must pay a water and sanitary service partial hookup fee at the time of final plat. 16. The developer shall work with the Building Department to determine the City SAC and WAC fees for the main building. 17. All work within the MnDOT right-of-way must be approved by MnDOT. 18. A full SWPPP meeting all the requirements of the NPDES permit must be provided to the city for review and approval prior to recording the final plat. 19. The applicant shall evaluate the practicality of implementing, to the "maximum extent practicable," volume -reducing practices including re -use. 20. All swales directing surface flows towards surface water features, including but not limited to storm sewer infrastructure, and off the subject property shall be stabilized within 48 hours of cessation of grading activities. 21. Erosion control blanket shall include the swales in their entirety. 22. The design of the stormwater BMPs shall follow the guidelines of the MN Stormwater Manual unless the City Engineer agrees to a deviation for those guidelines. 23. Pretreatment shall be provided for all filtration basins accepting water from driving and parking surfaces. G:\PLAN\2015 Planning Cases\2015-01 Mission Hills Senior Living\Approval letter Prelim Plat PUD and Site Plan.doc Mr. Michael Ho agb erg February 27, 2015 Page 9 24. A planting plan for the filtration features will be required before recording the final plat. 25. Topsoil shall meet, at a minimum, MnDOT specification 3877-2 "Loam Topsoil Borrow." 26. It is the applicant's responsibility to assure that permits are received from all other agencies with jurisdiction over the project. Planning Conditions: 1. The applicant shall work with staff to improve the screening of the southwesterly portion of the site through the use of berming and landscaping. 2. All rooftop and ground equipment must be screened from views. 3. The site is permitted one monument sign facing Great Plains Boulevard. Sign illumination and design shall comply with ordinance." A site plan agreement must be prepared by the city; however, cost estimates for the project must be submitted prior to document preparation. Final plat documents must be submitted to the City four weeks prior to the City Council meeting in which you wish to have your final plat approved. Enclosed is the list of items required for submittal for final plat approval. If you have any questions, please feel free to contact me at 952.227.1134 or e-mail at sal'' ac�ci. chanhassen.mn.us. Sincerely, A Sharmeen Al-Jaff Senior Planner Enclosure ec: Stephanie Smith, Project Engineer Klingelhutz Farms, LLC 545 Lake Drive #205 Chanhassen, MN 55317 Eric Reiners, Sperides Reiners Architects, Inc. G:\PLAN\2015 Planning Cases\2015-01 Mission Hills Senior Living\Approval letter Prelim Plat PUD and Site Plan.doc ITEMS REQUIRED FOR FINAL PLAT CONSIDERATION The following items are required to be submitted a minimum of 30 days prior to City Council meeting and payment of a $250.00 final plat review fee: 1. Submit three (3) sets of full size, 50 scale construction plans and specifications for staff review and redline. • Utility plans shall show both plan view and profiles of all utilities (sanitary sewer, water and storm sewer lines). The plan view must show all drainage and utility easements. • Grading and drainage plans shall show dwelling type and elevations, wetlands and wetland buffer areas, stormwater pond NWL and HWL, EOF and catch basin and storm manhole numbers. • The construction plans and specifications shall be in accordance to the City's latest edition of Standard Specifications & Detail Plates. • The plans shall include traffic signage and street light placement. 2. Drainage calculations for water quantity and quality ponding with maps showing drainage areas for pre -and post -development conditions and contributing areas to catch basins. 3. Hydraulic calculations and drainage map for the storm sewer design. 4. Tree Preservation Easements (if applicable). 5. Trail Easements (if applicable). 6. Engineer's Cost Estimate of Improvements: a. Sanitary sewer system. b. Water system. c. Storm sewer drainage system including cleaning and maintenance. d. Streets, sidewalk and trails. e. Erosion control. f. Site restoration (seeding, sodding, etc.). g. Site grading h. Street lights & signs i. Engineering, surveying & inspection j. Landscaping 7. Five (5) sets (folded) of final plat, one (1) set of reductions (8'/2" x 11 "), and a digital copy in .tif format. 8. Digital copy of the legal description of the property in a .doc format. 9. Lot tabulations. Failure to provide any of the above items by the required deadline result in delaying consideration of final plat before the City Council. Updated 11-29-06 c:\users\karene\appdata\local\microsoft\windows\temporary internet files\content.outlook\7vja9tov\final plat submittal.doc