Loading...
16-0057 GEO REPORT FINAL March 14, 2016 HGTS Project Number: 16-0057 Mr. Jon Connolly Gonyea Homes 1000 Boone Avenue North, Suite 400 Golden Valley, MN 55427 Re: Preliminary Geotechnical Exploration Report, Proposed Wilson Nursery Residential Development, 9150 Great Plains Boulevard, Chanhassen, Minnesota Dear Mr. Connolly: We have completed the preliminary geotechnical exploration report for the proposed Wilson Nursery residential development along Great Plains Boulevard in Chanhassen, Minnesota. The purpose of this geotechnical exploration was to characterize subsurface soil and ground water conditions and provide recommendations for site development. Most of the borings generally encountered about 1 to 2 feet topsoil overlying native clayey glacial till soils that extended to the termination depths of the borings. Borings SB-3, SB-6 and SB-7 encountered about 1 ½ to 7 feet of fill over about 2 ½ to 3 feet of buried topsoil underlain by about 2 to 3 feet of soft clays. Below the fill, buried topsoil and soft clays the borings also encountered native clayey glacial till soils that extended to termination depths of the borings. Groundwater was not encountered in the borings while drilling and sampling or after removing the augers from the boreholes to cave-in depths of 11 to 17 feet. The fill, topsoil and soft clay soils are not suitable for foundation support and corrections to remove these materials from within the building, roadway and oversize areas will be required. Based on the soil borings most of the corrections are anticipated to be on the order of 1 to 2 feet but at borings SB-3, SB-6 and SB-7 the corrections are anticipated to extend to depths of about 7 to 12 feet. The underlying native medium to stiff and medium dense clayey glacial till soils appear to be generally suitable for foundation support. Specific details regarding our procedures, results and recommendations follow in the attached geotechnical exploration report. Thank you for the opportunity to assist you on this project. If you have any questions or need additional information please contact Paul Gionfriddo at 763-954-1101 or John Carlson at 612-979-3542. Sincerely, HAUGO GEOTECHNICAL SERVICES, LLC Paul S. Gionfriddo P.E. John T. Carlson, P.E. Consulting Engineer Senior Engineer Copy: Mark Rausch, Alliant Engineering PRELIMINARY GEOTECHNICAL EXPLORATION REPORT PROJECT: Proposed Wilson Nursery Residential Development 9150 Great Plains Boulevard Chanhassen, Minnesota PREPARED FOR: Gonyea Homes 1000 Boone Avenue North, Suite 400 Golden Valley, MN 55427 PREPARED BY: Haugo GeoTechnical Services 2825 Cedar Avenue South Minneapolis, MN 55407 Haugo GeoTechnical Services Project: 16-0057 March 14, 2016 I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Registered Professional Engineer under the laws of the State of Minnesota. John T. Carlson, P.E. Project Engineer License Number 20663 Expires June, 2016 Table of Contents 1.0 INTRODUCTION 1 1.1 Project Description 1 1.2 Purpose 1 1.3 Site Description 1 1.4 Scope of Services 1 1.5 Documents Provided 2 1.6 Locations and Elevations 2 2.0 FIELD PROCEDURES 2 3.0 RESULTS 3 3.1 Soil Conditions 3 3.2 Groundwater 3 3.3 Laboratory Tests 4 3.4 OSHA Soil Classification 4 4.0 DISCUSSION AND RECOMMENDATIONS 4 4.1 Proposed Construction 4 4.2 Discussion 5 4.3 Mass Grading Recommendations 5 4.4 Dewatering 7 4.5 Interior Slabs 7 4.6 Below Grade Walls 7 4.7 Exterior Slabs 8 4.8 Site Grading and Drainage 9 4.9 Utilities 9 4.10 Bituminous Pavements 9 4.11 Infiltration Basin 10 5.0 CONSTRUCTION CONSIDERATIONS 11 5.1 Excavation 11 5.2 Observations 11 5.3 Backfill and Fills 11 5.4 Testing 11 5.5 Winter Construction 11 6.0 PROCEDURES 12 6.1 Soil Classification 12 6.2 Groundwater Observations 12 7.0 GENERAL 12 7.1 Subsurface Variations 12 7.2 Review of Design 13 7.3 Groundwater Fluctuations 13 7.4 Use of Report 13 7.5 Level of Care 13 APPENDIX 1 Soil Boring Location Sketch, Figure 1 GPS Boring Locations, Figure 2 Soil Boring Logs, SB-1 thru SB-10 Descriptive Terminology 1 1.0 INTRODUCTION 1.1 Project Description Gonyea Homes is proposing to develop the approximate 40 acre Wilson Nursery Site at 9150 Great Plains Boulevard in Chanhassen, Minnesota. Development plans include constructing about 45 single family homes along with the associated streets, underground utilities and storm water management areas. 1.2 Purpose Gonyea retained HGTS to perform a geotechnical exploration to evaluate the suitability of soil conditions to support the anticipated residential structures and provide recommendation for site development. 1.3 Site Description The project site is the Wilson Nursery property and is generally located south of Lyman Boulevard, east of U.S. Highway 212 and west of Great Plains Boulevard in Chanhassen, Minnesota. The property is an L-shaped parcel that is about 39 acres in size and contains a house, barn and nursery stock in the northern portion of the property. The southern portion of the property is mostly wooded with a few open grassy areas. The site topography is gently rolling to hilly and generally slopes to the west and south. Ground surface elevations at our boring locations ranged from about 896 to 933 feet mean sea level (MSL). 1.4 Scope of Services Our services were performed in accordance with the Haugo GeoTechnical Services LLC proposal 16-0057 which was dated January 27, 2016. Our scope of services was performed under the terms of our General Conditions and limited to the following tasks:  Completing ten (10) standard penetration test borings extending each to nominal depths of 20 feet.  Obtaining GPS coordinates and elevations at the soil boring locations.  Visually/manually classifying the samples recovered from the soil borings.  Performing laboratory tests on selected samples.  Preparing soil boring logs describing the materials encountered and the results of groundwater level measurements.  Preparing an engineering report describing soil and groundwater conditions, and providing recommendations for site development. 2 1.5 Documents Provided We were provided a concept plan titled “WILSON TREE FARM + ADJ. PROP. CONCEPT E” which was dated February 10, 2016 and prepared by Alliant Engineering. The concept plan showed the proposed development superimposed on an aerial photograph of the property. Site data was also provided on the concept plan. 1.6 Locations and Elevations The soil boring locations were selected by HGTS based on access and the proposed development areas. Ground surface elevations at the boring locations were obtained by HGTS using GPS measuring equipment. The GPS measurements were based on the MN County Coordinate System (Carver County) in US Survey Feet using the GEOID09 (Conus) model. The approximate location of the soil borings are shown on Figure 1, “Soil Boring Location Sketch”, in the Appendix. 2.0 FIELD PROCEDURES The 10 standard penetration test borings were advanced on March 1 and 2, 2016 by HGTS with a rotary drilling rig, using continuous flight augers to advance the boreholes. Representative samples were obtained from the borings, using the split-barrel sampling procedures in general accordance with ASTM Specification D-1586. In the split-barrel sampling procedure, a 2-inch O.D. split-barrel spoon is driven into the ground with a 140-pound hammer falling 30 inches. The number of blows required to drive the sampling spoon the last 12 inches of an 18-inch penetration is recorded as the standard penetration resistance value, or "N" value. The results of the standard penetration tests are indicated on the boring log. The samples were sealed in containers and provided to the HGTS office for testing and soil classification. A field log of each boring was prepared by the HGTS drill crew. The logs contained visual classifications of the soil materials encountered during drilling, as well as the driller's interpretation of the subsurface conditions between samples and water observation notes. The final boring logs included with this report represent an interpretation of the field logs and include modifications based on visual/manual method observation of the samples. The soil boring logs, general terminology for soil description and identification, and classification of soils for engineering purposes are also included in the appendix. The soil boring logs identify and describe the materials encountered, the relative density or consistency based on the Standard Penetration resistance (N-value, “blows per foot”) and groundwater observations. The strata changes were inferred from the changes in the samples and auger cuttings. The depths shown as changes between strata are only approximate. The changes are likely transitions, variations can occur beyond the location of the boring. 3 3.0 RESULTS 3.1 Soil Conditions Most of the borings generally encountered about 1 to 2 feet topsoil overlying native clayey glacial till soils that extended to the termination depths of the borings. The topsoil predominantly consisted of sandy lean clay that contained some roots and was black in color. Borings SB-3, SB-6 and SB-7 encountered about 1 ½ to 7 feet of fill over about 2 ½ to 3 feet of buried clayey or sandy topsoil. The Fill included a variety of soil types including silty sand, clayey sand and sandy lean clay. Most of the fill was dark brown to black in color and bituminous was encountered at a depth of about 5 feet in boring SB-7. Below the Fill and/or topsoil the borings encountered native clayey glacial till soils that extended to termination depths of the borings. The native glacial till soils consist predominantly consisted of sandy lean clay and clayey sand with lesser amounts of silty sand. Penetration resistance values (N-Values), shown as blows per foot (bpf) on the boring log, within the glacial till soils ranged from 4 to 21 bpf. These values indicate the glacial till soils to be generally medium to very stiff in consistency or in a medium dense density with upper soft areas encountered at borings SB-3, SB-6 and SB-7. An N-Value greater than 50 bpf was recorded at a depth of about 20 feet in boring SB-8 which was likely due to gravel, cobbles or boulders with the soil. 3.2 Groundwater Groundwater was not encountered in the soil borings while drilling and sampling or after removing the augers from the boreholes to cave-in depths of 11 to 17 feet. It appears that groundwater levels were below the depths explored. However, given the cohesive nature of the soil encountered, it is likely that insufficient time was available for groundwater to seep into the boring(s) and rise to its hydrostatic level. Groundwater levels could be higher. In addition the sandy lean clay glacial till can contain sand seams or sand layers and ground water can be encountered within them. These sand seams or layers, if any, may not become apparent until construction. The water level of the pond to the south and Lake Riley to the east of the site is about 875 feet. The water level of the large wetland to the northwest of the site is about 885 feet. Groundwater measurements were made as noted and shown on the boring logs. Groundwater monitoring wells or piezometers would be required to more accurately determine water levels. Seasonal and annual fluctuations in the groundwater levels should be expected. 4 3.3 Laboratory Tests Laboratory moisture content tests were performed on selected samples recovered from the soil borings. Moisture contents ranged from about 10 ½ to 30 ½ percent indicating the soils are likely near to above their optimum moisture content. Table 1 below summarizes the results of the laboratory tests. Results of the laboratory moisture content tests are also shown on the boring logs adjacent to the sample tested. Table 1. Summary of Laboratory Tests Boring Number Sample Number Depth (feet) Moisture Content (%)* SB-1 S-3 5 15 ½ SB-2 S-10 2 ½ 15 ½ SB-3 S-19 5 18 SB-3 S-21 10 25 SB-5 S-36 7 ½ 10 ½ SB-6 S-43 5 30 ½ SB-6 S-46 12 ½ 20 ½ SB-7 S-53 10 20 ½ SB-8 S-58 2 ½ 20 ½ SB-9 S-68 7 ½ 18 ½ SB-10 S-75 5 17 *Moisture contents were rounded to the nearest ½ percent 3.4 OSHA Soil Classification The soils encountered in the borings primarily consisted of clayey soils corresponding to the ASTM Classification CL or SC. The clayey soils identified in the borings will be Type B soils under Department of Labor Occupational Safety and Health Administration (OSHA) guidelines. Silty sand soils were also encountered in the borings which correspond to the ASTM Classification SM. The silty sand identified in the borings will be Type C soils under Department of Labor Occupational Safety and Health Administration (OSHA) guidelines. 4.0 DISCUSSION AND RECOMMENDATIONS 4.1 Proposed Construction Final grading or construction plans for the development were not available at the time of this report. We understand the project will consist of preparing about 45 house pads and the associated streets, underground utilities and storm water management areas (ponds/infiltration basins). 5 We anticipate that the new homes will be full-basement, full basement walkout, walkout or lookout styles and will include one or two stories above grade. The new homes will likely consist of cast-in-place concrete or masonry block foundation walls supported on concrete spread footings. We anticipate above grade construction to consist of wood framing, a pitched roof and asphalt shingles. Based on the assumed construction we estimate wall loadings will range from about 1 to 2 kips (1,000 to 2,000 pounds) per lineal foot and column loads, if any, will be less than 50 kips (50,000 pounds). 4.2 Discussion Most of the borings generally encountered about 1 to 2 feet topsoil overlying native clayey glacial till soils that extended to the termination depths of the borings. Borings SB-3, SB-6 and SB-7 encountered about 1 ½ to 7 feet of fill over about 2 ½ to 3 feet of buried topsoil underlain by about 2 to 3 feet of soft clays. Below the fill, buried topsoil and soft clays the borings also encountered native clayey glacial till soils that extended to termination depths of the borings. Groundwater was not encountered in the borings while drilling and sampling or after removing the augers from the boreholes to cave-in depths of 11 to 17 feet. The vegetation, fill, topsoil and soft or very loose soils are not suitable for foundation support and corrections to remove these materials from within the building and oversize areas will be required. Based on the soil borings most of the corrections are anticipated to be on the order of 1 to 2 feet but at borings SB-3, SB-6 and SB-7 the corrections are anticipated to extend to depths of about 7 to 12 feet. The underlying medium to stiff or medium dense native glacial till soils appear generally suitable for foundation support. Groundwater was not encountered in the borings while drilling and sampling or after removing the augers from the boreholes to cave-in depths of 11 to 17 feet. We do not anticipate that groundwater will be encountered during construction. 4.3 Mass Grading Recommendations Excavation We recommend that all vegetation, topsoil, existing fill soils, buried topsoil and any soft or loose soil be removed from the proposed house and oversize areas. We anticipate that the existing structures on the property will be demolished for the proposed development. We recommend that any building remnants or debris associated with any existing or former structure(s) including footings, foundation walls, floor slabs and utilities be removed from within the building and oversize areas. Table 2 below summarizes the anticipated excavation depths at the boring locations. Excavation depths may vary and could be deeper. 6 Table 2. Anticipated Mass Grading Excavation Depths Boring Number Measured Surface Elevation (feet) Anticipated Excavation Depth (feet)* Anticipated Excavation Elevation (feet)* SB-1 921.6 1 920 ½ SB-2 911.0 1 910 SB-3 915.8 Pond Area - SB-4 896.1 2 894 SB-5 899.1 Pond Area - SB-6 893.1 7 886 SB-7 896.5 12 884 ½ SB-8 901.7 1 900 ½ SB-9 918.5 1 917 ½ SB-10 933.3 1 932 ½ *Excavation depths and elevation were rounded to the nearest ½ foot. Oversizing Where excavations for soil corrections extend below the proposed footing or house pad elevations oversizing (widening) of the excavations will be required. This oversizing is required to provide lateral support of the replacement backfill and the structural loads it will support. We recommend oversizing (widening) the excavation 1 foot horizontally beyond the outer edges of the perimeter house pads for each foot the excavation extends below the bottom of the desired pad elevation (1H:1V oversizing). Soil Backfill Fill required to attain site grades and may consist of any debris-free, non- organic mineral soil. Based on the soil borings, the on-site native glacial till soils identified as sandy lean clay, clayey sand and silty sand appear generally suitable for re- use as fill or backfill provided it is free of organic material or other deleterious material. Some moisture conditioning (drying or wetting) of these soils will likely be required to meet the recommended compaction levels. The topsoil and buried topsoil, including soils that are black in color, are not suitable for re-use as fill or backfill. It may be possible to re-use these materials in “green areas” on the site such as landscaping berms. Compaction We recommend that backfill placed to attain site grades be compacted to a minimum of 95 percent of its standard Proctor density (ASTM D 698). All fill soils should be placed within 3 percentage points above and 1 percentage point below its optimum moisture content as determined by the standard Proctor. All fill should be placed in thin lifts and be compacted with a large self-propelled vibratory compactor operating in vibratory mode. In areas where fill depths will exceed 10 feet we recommend that compaction levels be increased to minimum of 100 percent of the materials standard Proctor density. Even with the increased compaction levels a construction delay may be appropriate to allow for post construction settlement of the fill mass. Fill and backfill placed on slopes, if any, must be “benched” into the underlying suitable soil to reduce the potential for slip planes to develop between the fill and underlying 7 soil. We recommend “benching” or excavating into the slope at 2 feet vertical intervals to key the fill into the slope. We recommend each bench be a minimum of 5 feet wide. Foundations We recommend the perimeter footings bear a minimum of 42 inches below the exterior grade for frost protection. Interior footings may be placed immediately below the slab provided construction does not occur during below freezing weather conditions. Foundation elements in unheated areas should bear at least 5 feet below exterior grade for frost protection. We anticipate the foundations and floor slabs will bear on compacted engineered fill or native clayey soils (sandy lean clay or clayey sand). With the building pads prepared as recommended it is our opinion the footings can be designed for a net allowable bearing pressure up to 2,000 pounds per square foot (psf). We anticipate total and differential settlement of the foundations will be less than 1 inch and ½ inch, respectively. 4.4 Dewatering Groundwater was not encountered in the soil borings and we do not anticipate that dewatering will be required. 4.5 Interior Slabs If floor coverings or coatings less permeable than the concrete slab will be used, we recommend that a vapor retarder or vapor barrier be placed immediately beneath the slab. Some contractors prefer to bury the vapor barrier or vapor retarder beneath a layer of sand to reduce curling and shrinkage, but this practice often traps water between the slab and vapor retarder or barrier. Regardless of where the vapor retarder or vapor barrier is placed, we recommend consulting the floor covering manufacturer regarding the appropriate type, use and installation of the vapor retarder or vapor barrier to preserve the warranty. We recommend following all state and local building codes in regards to a radon mitigation plan beneath interior slabs. 4.6 Below Grade Walls Full basement, walkout and lookout style homes will likely have foundation walls or below grade (partial basement) walls that will have lateral loads from the surrounding soil transmitted to them. Site soil consisted predominantly of clayey/cohesive soils. We recommend general waterproofing of the below grade walls because of the potential cost impacts related to seepage after construction. We recommend installing drain tile behind the below grade walls, adjacent to the wall footing and below the slab elevation. Preferably the drain tile should consist of perforated pipe embedded in gravel. A geotextile filter fabric should encase the pipe and gravel. The drain tile should be routed to a storm sewer, sump pump or other suitable discharge site. 8 Unless a drainage composite is placed against the backs of the exterior perimeter below- grade walls we recommend that backfill placed within 2 feet of the walls consist of sand having less than 50 percent of the particles by weight passing the #40 sieve and less than 5 percent of the particles by weight passing the #200 sieve. We recommend the balance of the backfill for the walls consist of sand however the sand may contain up to 20 percent of the particles by weight passing the #200 sieve. Foundation walls or below grade (basement) walls will have lateral loads from the surrounding soil transmitted to them. Active earth pressures can be used to design the below grade walls if the walls are allowed to rotate slightly. If wall rotation cannot be tolerated then below grade wall design should be based on at-rest earth pressures. We recommend the following soil parameters be used for below grade/retaining wall design, shown in Table 3. These design parameters are based on the assumptions that the walls are drained, there are no surcharge loads within a horizontal distance equal to the height of the wall and the backfill is level. Table 3. Soil Parameters Soil Type Estimated Unit Weight (pcf) Estimated Friction Angle (degrees) At-Rest Pressure (pcf) Active Soil Pressure (pcf) Passive Soil Pressure (pcf) Clay 135 28 70 50 375 Sand 125 32 60 40 405 Resistance to lateral earth pressures will be provided by passive resistance against the wall footings and by sliding resistance along the bottom of the wall footings. We recommend a sliding coefficient of 0.35. This value does not include a factor of safety. 4.7 Exterior Slabs Exterior slabs will likely be underlain by clayey soils which are considered moderately frost susceptible. If these soils become saturated and freeze, significant heave may occur. This heave can be a nuisance in front of doors and at other critical grade areas. One way to help reduce the potential for heaving is to remove the frost-susceptible soils below the slabs down to bottom of footing grades, and replace them with non-frost-susceptible backfill consisting of sand having less than 5 percent of the particles by weight passing the number 200 sieve. If this approach is used and the excavation bottoms terminate in non-free draining granular soil we recommend a drain tile be installed along the bottom outer edges of the excavation to collect and remove any water that may accumulate within the sand. The bottom of the excavation should be graded away from the building. If the banks of the excavations to remove the frost-susceptible soils are not sloped, abrupt transitions between the frost-susceptible and non-frost-susceptible backfill will exist along which unfavorable amounts of differential heaving may occur. Such transitions could exist between exterior slabs and sidewalks, between exterior slabs and pavements and along the slabs themselves if the excavations are confined to only the building entrances. To address this issue we recommend sloping the excavations to remove frost-susceptible soils at a minimum 3:1 (horizontal: vertical) gradient. 9 An alternative method of reducing frost heave is to place a minimum of 2 inches of extruded polystyrene foam insulation beneath the slabs and extending it about 4 feet beyond the slabs. The insulation will reduce frost penetration into the underlying soil and reduce heave. Six to 12 inches of granular soil is typically placed over the insulation to protect it during construction. Another alternative for reducing frost heave is to support the slabs on frost depth footings. A void space of at least 4 inches should be provided between the slab and the underlying soil to allow the soil to heave without affecting the slabs. 4.8 Site Grading and Drainage We recommend the site be graded to provide positive run-off away from the proposed houses. We recommend landscaped areas be sloped a minimum of 6 inches within 10 feet of the house and slabs be sloped a minimum of 2 inches. In addition we recommend downspouts with long splash blocks or extensions for each house. We recommend the lowest floor grades be constructed to maintain at least a 2-foot separation between the lowest floor slab and 100 year flood levels of any adjacent water features such as wetlands, ponds or infiltration basins. 4.9 Utilities We anticipate that the utilities will be supported on native the glacial till soils which in our opinion are suitable for pipe support. We recommend removing all existing fill, topsoil, buried topsoil, soft or loose or other unsuitable soil, if encountered, beneath utilities prior to placement. We recommend bedding material be thoroughly compacted around the pipes. We recommend trench backfill above the pipes be compacted to a minimum of 95 percent beneath slabs and pavements, the exception being within 3 feet of the proposed pavement subgrade, where 100 percent of standard Proctor density is required. In landscaped areas we recommend a minimum compaction of 90 percent. 4.10 Bituminous Pavements We anticipate that the bituminous pavements will be constructed in accordance with the City of Chanhassen standard plates which include a sand subbase. The following paragraphs provide pavement recommendations in the absence of City of Chanhassen standard plates. We recommend removing all vegetation, topsoil, or other unsuitable materials from within the pavement subgrade. Backfill, if needed, to attain pavement subgrade elevation can consist of any mineral soil provided it is free of organic material or other deleterious materials. We recommend compacting the backfill at moisture contents within a range of 1 percentage point below and 3 percentage points above its optimum moisture content. The upper 3 feet of fill and backfill should be compacted to a minimum of 100 percent of its standard Proctor maximum dry density. 10 The new pavements will be constructed with a drained sand sub-base below the aggregate base course. We recommend using sand with less than 12% passing the #200 sieve, such as MN/DOT 3149.2B2 (Select Granular Borrow). We recommend the sub- base extend beneath the curbs and to 2 feet beyond the outside edges of the curbs for frost and drainage uniformity. Sand layers outside the curbs should be capped with slow draining soil to reduce surface water infiltration. We recommend drainpipes (finger drains) be installed in the sand sub-base to remove infiltrating water. The finger drains should be connected to the catch basins. The slope of the bottom of the sub-cut should be such that water is directed to the drainage areas. The sub-cut bottom should not include depressions that can act as reservoirs for water collection. We recommend aggregate base meeting MN/DOT specification 3138 for Class 5 aggregate base. We recommend the aggregate base be compacted to 100 percent of its maximum standard Proctor dry density. We recommend that the bituminous wear and base courses meet the requirement of MN/DOT specification 2360. We recommend the bituminous pavements be compacted to at least 92% of the maximum theoretical density. The streets/roadways will include concrete curb and gutter. We recommend specifying concrete that has a minimum 28 day compressive strength of 3,900 psi. We recommend specifying 5 to 8 percent entrained air for exposed concrete to provide resistance to freeze-thaw deterioration. We recommend slump, air content and compressive strength test of Portland cement concrete. 4.11 Infiltration Basin Soil borings SB-3 and SB-5 were performed in the proposed storm water management areas (ponds/infiltration basins). These borings encountered about 1 to 5 feet of topsoil or clayey fill/buried topsoil overlying native clayey/cohesive glacial till soils. We were not provided any information regarding pond depths but anticipate the bottoms of the ponds will bear about 5 to 10 feet below existing site grades. We recommend using the infiltration rates presented in Table 1 below, which were obtained from Table 12.BIO.8 of the “Minnesota Storm Water Manual”, Revised December 16, 2013, for infiltration basin design. Table 1. Design Infiltration Rates In-situ soils Soil Description Design Infiltration Rate (in/hr) SM Silty Sand 0.45 SC Clayey Sand 0.2 CL Sandy Lean Clay 0.06 11 Field tests (double ring infiltrometer) can be performed within the proposed infiltration basin area to verify infiltration rates of the in-situ soils. We would be pleased to provide these services if required or requested. 5.0 CONSTRUCTION CONSIDERATIONS 5.1 Excavation The borings indicated that at the anticipated excavation depths the sand soils in the sidewalls of the excavations will be primarily Type B soil under Department of Labor Occupational Safety and Health Administration (OSHA) guidelines. Temporary excavations in Type C soils should be constructed at a minimum of 1 foot horizontal to every 1 foot vertical. Slopes constructed in this manner may still exhibit surface sloughing. If site constraints do not allow the construction of slopes with these dimensions then temporary shoring may be required. 5.2 Observations A geotechnical engineer should observe the excavation subgrade to evaluate if the subgrade soils are similar to those encountered in the borings and adequate to support the proposed construction. 5.3 Backfill and Fills The native glacial till soils appear to be above their assumed optimum moisture contents. Some moisture conditioning (drying) of these soils may be required, depending, in part on seasonal factors, to achieve the recommended compaction. We recommend that fill and backfill be placed in lifts not exceeding 4 to 12 inches, depending on the size of the compactor and materials used. 5.4 Testing We recommend density tests of backfill and fills placed for the new house pads. Samples of the proposed materials should be submitted to our laboratory prior to placement for evaluation of their suitability and to determine their optimum moisture content and maximum dry density (Standard Proctor). 5.5 Winter Construction If site grading and construction is anticipated to proceed during cold weather, all snow and ice should be removed from cut and fill areas prior to additional grading and placement of fill. No fill should be placed on frozen soil and no frozen soil should be used as fill or backfill. Concrete delivered to the site should meet the temperature requirements of ASTM and/or ACI. Concrete should not be placed on frozen soil. Concrete should be 12 protected from freezing until the necessary strength is obtained. Frost should not be permitted to penetrate below the footings. 6.0 PROCEDURES 6.1 Soil Classification The drill crew chief visually and manually classified the soils encountered in the borings in general accordance with ASTM D 2488, “Description and Identification of Soils (Visual-Manual Procedure)”. Soil terminology notes are included in the Appendix. The samples were returned to our laboratory for review of the field classification by a soils engineer. Samples will be retained for a period of 30 days. 6.2 Groundwater Observations Immediately after taking the final samples in the bottom of the borings, the holes were checked for the presence of groundwater. Immediately after removing the augers from the borehole the holes were once again checked and the depth to water and cave-in depths were noted. 7.0 GENERAL 7.1 Subsurface Variations The analyses and recommendations presented in this report are based on data obtained from a limited number of soil borings. Variations can occur away from the borings, the nature of which may not become apparent until additional exploration work is completed or construction is conducted. A reevaluation of the recommendations in this report should be made after performing on-site observations during construction to note the characteristics of any variations. The variations may result in additional foundation costs and it is suggested that a contingency be provided for this purpose. It is recommended that we be retained to perform the observation and testing program during construction to evaluate whether the design is as expected, if any design changes have affected the validity of our recommendations, and if our recommendations have been correctly interpreted and implemented in the designs, specifications and construction methods. This will allow correlation of the soil conditions encountered during construction to the soil borings and will provide continuity of professional responsibility. 13 7.2 Review of Design This report is based on the design of the proposed development as related to us for preparation of this report. It is recommended that we be retained to review the geotechnical aspects of the design and specifications. With the review we will evaluate whether any changes have affected the validity of the recommendations and whether our recommendations have been correctly interpreted and implemented in the design and specifications. 7.3 Groundwater Fluctuations We made water level measurements in the borings at the times and under the conditions stated on the boring logs. The data was interpreted in the text of this report. The period of observation was relatively short and fluctuations in the groundwater level may occur due to rainfall, flooding, irrigation, spring thaw, drainage, and other seasonal and annual factors not evident at the time the observations were made. Design drawings and specifications and construction planning should recognize the possibility of fluctuations. 7.4 Use of Report This report is for the exclusive use of Gonyea Homes & Remodeling and their design team to use to design the proposed structure and prepare construction documents. In the absence of our written approval, we make no representation and assume no responsibility to other parties regarding this report. The data, analysis and recommendations may not be appropriate for other structures or purposes. We recommend that parties contemplating other structures or purposes contact us. 7.5 Level of Care Haugo GeoTechnical Services, LLC has used the degree of skill and care ordinarily exercised under similar circumstance by members of the profession currently practicing in this locality. No warranty expressed or implied is made. APPENDIX = Approximate Soil Boring Location SB-1 SB-3 SB-4 SB-2 Haugo GeoTechnical Services. 2825 Cedar Avenue S. Minneapolis, MN 55407 Figure #: 1 Drawn By: RD Date: 3/7/16 Scale: None Project #: 16-0057 Soil Boring Location Sketch 9150 Great Plains Blvd Chanhassen, Minnesota SB-5 SB-8 SB-7 SB-9 SB-10 SB-6 HGTS# 16-0057 Figure 2: GPS Boring Locations Referencing Minnesota County Coordinates Basis – Carver County (GEOID09 Conus model). Boring Number Elevation (US Survey Feet) Northing Coordinate Easting Coordinate SB-1 921.61 172144.56 558957.97 SB-2 911.05 172431.90 558778.41 SB-3 915.76 172403.54 558952.04 SB-4 896.10 172476.48 558577.12 SB-5 899.12 172140.88 558195.84 SB-6 893.11 172355.02 558535.52 SB-7 896.47 172342.75 558664.28 SB-8 901.74 172170.82 558423.03 SB-9 918.53 171988.09 558298.23 SB-10 933.32 171706.59 558300.35 Sandy Lean Clay, dark brown, moist to wet. (Topsoil) (CL) Sandy Lean Clay, trace Gravel, brown with rust staining, moist to wet, rather stiff to very stiff.(Glacial Till) Bottom of borehole at 21.0 feet. AU 1 SS2 SS3 SS4 SS5 SS6 SS 7 SS8 4-5-5(10) 4-6-7(13) 6-7-9(16) 3-6-7(13) 4-6-7(13) 4-8-8 (16) 3-9-9(18) NOTES GROUND ELEVATION 921.6 ft LOGGED BY MS DRILLING METHOD Hollow Stem Auger/Split Spoon DRILLING CONTRACTOR HGTS GROUND WATER LEVELS: CHECKED BY JC DATE STARTED 3/1/16 COMPLETED 3/1/16 AT TIME OF DRILLING --- Not Encountered AT END OF DRILLING --- Not Encountered AFTER DRILLING --- Not Encountered at Cave-In Depth of 14 feet HOLE SIZE 3 1/4 inches FINES CONTENT (%) 20 40 60 80 20 40 60 80 PL LLMC DE P T H (f t ) 0 5 10 15 20 GR A P H I C LO G MATERIAL DESCRIPTION SA M P L E T Y P E NU M B E R RE C O V E R Y % (R Q D ) BL O W CO U N T S (N V A L U E ) PO C K E T P E N . (t s f ) DR Y U N I T W T . (p c f ) SPT N VALUE 20 40 60 80 PAGE 1 OF 1 BORING NUMBER SB-1 CLIENT Gonyea Homes PROJECT NUMBER 16-0057 PROJECT NAME Wilson Nursery PROJECT LOCATION Chanhassen, MN GE O T E C H B H P L O T S - G I N T S T D U S L A B . G D T - 3 / 1 4 / 1 6 1 2 : 5 4 - C : \ U S E R S \ P U B L I C \ D O C U M E N T S \ B E N T L E Y \ G I N T \ P R O J E C T S \ 1 6 - 0 0 5 7 W I L S O N N U R S E R Y . G P J Haugo GTS 2825 Cedar Ave S Minneapolis, MN 55407 Telephone: 612-729-2959 Fax: 763-445-2238 Sandy Lean Clay, trace Roots, dark brown, wet. (Topsoil) (CL) Sandy Lean Clay, trace Gravel, with Poorly Graded Sandseam at about 15 feet, brown with rust staining, moist to wet,medium to very stiff. (Glacial Till) Bottom of borehole at 21.0 feet. AU 9 SS10 SS11 SS12 SS13 SS14 SS 15 SS16 3-3-5(8) 5-6-7(13) 6-9-11(20) 4-8-9(17) 4-9-9(18) 4-7-8 (15) 9-9-10(19) NOTES GROUND ELEVATION 911 ft LOGGED BY MS DRILLING METHOD Hollow Stem Auger/Split Spoon DRILLING CONTRACTOR HGTS GROUND WATER LEVELS: CHECKED BY JC DATE STARTED 3/1/16 COMPLETED 3/1/16 AT TIME OF DRILLING --- Not Encountered AT END OF DRILLING --- Not Encountered AFTER DRILLING --- Not Encountered at Cave-In Depth of 16 feet HOLE SIZE 3 1/4 inches FINES CONTENT (%) 20 40 60 80 20 40 60 80 PL LLMC DE P T H (f t ) 0 5 10 15 20 GR A P H I C LO G MATERIAL DESCRIPTION SA M P L E T Y P E NU M B E R RE C O V E R Y % (R Q D ) BL O W CO U N T S (N V A L U E ) PO C K E T P E N . (t s f ) DR Y U N I T W T . (p c f ) SPT N VALUE 20 40 60 80 PAGE 1 OF 1 BORING NUMBER SB-2 CLIENT Gonyea Homes PROJECT NUMBER 16-0057 PROJECT NAME Wilson Nursery PROJECT LOCATION Chanhassen, MN GE O T E C H B H P L O T S - G I N T S T D U S L A B . G D T - 3 / 1 4 / 1 6 1 2 : 5 5 - C : \ U S E R S \ P U B L I C \ D O C U M E N T S \ B E N T L E Y \ G I N T \ P R O J E C T S \ 1 6 - 0 0 5 7 W I L S O N N U R S E R Y . G P J Haugo GTS 2825 Cedar Ave S Minneapolis, MN 55407 Telephone: 612-729-2959 Fax: 763-445-2238 Sandy Lean Clay, with Gravel, brown and grey, moist to wet. (FILL) Silty Sand, trace Roots and Fibers, black, moist. (Buried Topsoil) (SC) Clayey Sand, grey, moist to wet, very loose. (Glacial Till) (CL) Sandy Lean Clay, trace Roots, light grey with rust staining atabout 10 feet, wet, rather stiff. (Glacial Till) (CL) Sandy Lean Clay, trace Gravel, brown with rust staining, moist to wet, stiff to very stiff. (Glacial Outwash) Bottom of borehole at 21.0 feet. AU 17 SS18 SS19 SS20 SS21 SS22 SS 23 SS24 2-3-2(5) 1-2-2(4) 2-4-5(9) 2-4-5(9) 3-6-8(14) 3-9-10 (19) 6-8-10(18) NOTES GROUND ELEVATION 915.8 ft LOGGED BY MS DRILLING METHOD Hollow Stem Auger/Split Spoon DRILLING CONTRACTOR HGTS GROUND WATER LEVELS: CHECKED BY JC DATE STARTED 3/1/16 COMPLETED 3/1/16 AT TIME OF DRILLING --- Not Encountered AT END OF DRILLING --- Not Encountered AFTER DRILLING --- Not Encountered at Cave-In Depth of 14 feet HOLE SIZE 3 1/4 inches FINES CONTENT (%) 20 40 60 80 20 40 60 80 PL LLMC DE P T H (f t ) 0 5 10 15 20 GR A P H I C LO G MATERIAL DESCRIPTION SA M P L E T Y P E NU M B E R RE C O V E R Y % (R Q D ) BL O W CO U N T S (N V A L U E ) PO C K E T P E N . (t s f ) DR Y U N I T W T . (p c f ) SPT N VALUE 20 40 60 80 PAGE 1 OF 1 BORING NUMBER SB-3 CLIENT Gonyea Homes PROJECT NUMBER 16-0057 PROJECT NAME Wilson Nursery PROJECT LOCATION Chanhassen, MN GE O T E C H B H P L O T S - G I N T S T D U S L A B . G D T - 3 / 1 4 / 1 6 1 2 : 5 5 - C : \ U S E R S \ P U B L I C \ D O C U M E N T S \ B E N T L E Y \ G I N T \ P R O J E C T S \ 1 6 - 0 0 5 7 W I L S O N N U R S E R Y . G P J Haugo GTS 2825 Cedar Ave S Minneapolis, MN 55407 Telephone: 612-729-2959 Fax: 763-445-2238 5 inches of Aggregate Base. Sandy Lean Clay, trace Roots, black. (Buried Topsoil) (CL) Sandy Lean Clay, trace Gravel, light grey with rust staining,moist to wet, rather stiff. (Glacial Till) (CL) Sandy Lean Clay, trace Gravel, brown, moist to wet, ratherstiff to very stiff. (Glacial Till) (CL) Sandy Lean Clay, trace Gravel, grey, moist to wet, very stiff.(Glacial Till) Bottom of borehole at 21.0 feet. AU 25 SS26 SS27 SS28 SS29 SS30 SS 31 SS32 3-4-6(10) 3-4-5(9) 3-6-9(15) 4-6-6(12) 7-8-8(16) 4-10-9 (19) 5-7-11(18) NOTES GROUND ELEVATION 896.1 ft LOGGED BY MS DRILLING METHOD Hollow Stem Auger/Split Spoon DRILLING CONTRACTOR HGTS GROUND WATER LEVELS: CHECKED BY JC DATE STARTED 3/1/16 COMPLETED 3/1/16 AT TIME OF DRILLING --- Not Encountered AT END OF DRILLING --- Not Encountered AFTER DRILLING --- Not Encountered at Cave-In Depth of 12 feet HOLE SIZE 3 1/4 inches FINES CONTENT (%) 20 40 60 80 20 40 60 80 PL LLMC DE P T H (f t ) 0 5 10 15 20 GR A P H I C LO G MATERIAL DESCRIPTION SA M P L E T Y P E NU M B E R RE C O V E R Y % (R Q D ) BL O W CO U N T S (N V A L U E ) PO C K E T P E N . (t s f ) DR Y U N I T W T . (p c f ) SPT N VALUE 20 40 60 80 PAGE 1 OF 1 BORING NUMBER SB-4 CLIENT Gonyea Homes PROJECT NUMBER 16-0057 PROJECT NAME Wilson Nursery PROJECT LOCATION Chanhassen, MN GE O T E C H B H P L O T S - G I N T S T D U S L A B . G D T - 3 / 1 4 / 1 6 1 2 : 5 5 - C : \ U S E R S \ P U B L I C \ D O C U M E N T S \ B E N T L E Y \ G I N T \ P R O J E C T S \ 1 6 - 0 0 5 7 W I L S O N N U R S E R Y . G P J Haugo GTS 2825 Cedar Ave S Minneapolis, MN 55407 Telephone: 612-729-2959 Fax: 763-445-2238 Sandy Lean Clay, trace Roots, black, wet. (Topsoil) (CL) Sandy Lean Clay, trace Gravel, brown, moist, very stiff. (Glacial Till) (SC-SM) Silty Clayey Sand, trace Gravel, brown, moist, mediumdense. (Glacial Till) (SM) Silty Sand, mostly fine to medium grained, trace Gravel,brown, moist, medium dense. (Glacial Till) (CL) Sandy Lean Clay, trace Gravel, brown, moist, stiff to very stiff. (Glacial Till) Bottom of borehole at 21.0 feet. AU 33 SS34 SS35 SS36 SS37 SS38 SS 39 SS40 5-9-9(18) 5-7-8(15) 10-10-9(19) 4-5-9(14) 7-7-10(17) 4-6-9 (15) 8-8-8(16) NOTES GROUND ELEVATION 899.1 ft LOGGED BY MS DRILLING METHOD Hollow Stem Auger/Split Spoon DRILLING CONTRACTOR HGTS GROUND WATER LEVELS: CHECKED BY JC DATE STARTED 3/1/16 COMPLETED 3/1/16 AT TIME OF DRILLING --- Not Encountered AT END OF DRILLING --- Not Encountered AFTER DRILLING --- Not Encountered at Cave-In Depth of 16 feet HOLE SIZE 3 1/4 inches FINES CONTENT (%) 20 40 60 80 20 40 60 80 PL LLMC DE P T H (f t ) 0 5 10 15 20 GR A P H I C LO G MATERIAL DESCRIPTION SA M P L E T Y P E NU M B E R RE C O V E R Y % (R Q D ) BL O W CO U N T S (N V A L U E ) PO C K E T P E N . (t s f ) DR Y U N I T W T . (p c f ) SPT N VALUE 20 40 60 80 PAGE 1 OF 1 BORING NUMBER SB-5 CLIENT Gonyea Homes PROJECT NUMBER 16-0057 PROJECT NAME Wilson Nursery PROJECT LOCATION Chanhassen, MN GE O T E C H B H P L O T S - G I N T S T D U S L A B . G D T - 3 / 1 4 / 1 6 1 2 : 5 5 - C : \ U S E R S \ P U B L I C \ D O C U M E N T S \ B E N T L E Y \ G I N T \ P R O J E C T S \ 1 6 - 0 0 5 7 W I L S O N N U R S E R Y . G P J Haugo GTS 2825 Cedar Ave S Minneapolis, MN 55407 Telephone: 612-729-2959 Fax: 763-445-2238 4 inches of Aggregate Base. Mixed FIll: Poorly Graded Sand and Clayey Sand, with Gravel,black to brown and grey, moist. (FILL) Sandy Lean Clay, trace Roots and Fibers, black, wet.(Buried Topsoil) (CL) Sandy Lean Clay, trace Fibers at about 5 feet, trace Gravel,grey, moist to wet, rather soft to rather stiff. (Glacial Till) (SC) Clayey Sand, trace Gravel, greyish brown, moist to wet,medium dense. (Glacial Till) Bottom of borehole at 21.0 feet. AU 41 SS42 SS43 SS44 SS45 SS46 SS 47 SS48 2-2-3(5) 2-2-3(5) 2-3-3(6) 3-4-4(8) 2-3-4(7) 3-4-5 (9) 2-6-7(13) NOTES GROUND ELEVATION 893.1 ft LOGGED BY MS DRILLING METHOD Hollow Stem Auger/Split Spoon DRILLING CONTRACTOR HGTS GROUND WATER LEVELS: CHECKED BY JC DATE STARTED 3/1/16 COMPLETED 3/1/16 AT TIME OF DRILLING --- Not Encountered AT END OF DRILLING --- Not Encountered AFTER DRILLING --- Not Encountered at Cave-In Depth of 14 feet HOLE SIZE 3 1/4 inches FINES CONTENT (%) 20 40 60 80 20 40 60 80 PL LLMC DE P T H (f t ) 0 5 10 15 20 GR A P H I C LO G MATERIAL DESCRIPTION SA M P L E T Y P E NU M B E R RE C O V E R Y % (R Q D ) BL O W CO U N T S (N V A L U E ) PO C K E T P E N . (t s f ) DR Y U N I T W T . (p c f ) SPT N VALUE 20 40 60 80 PAGE 1 OF 1 BORING NUMBER SB-6 CLIENT Gonyea Homes PROJECT NUMBER 16-0057 PROJECT NAME Wilson Nursery PROJECT LOCATION Chanhassen, MN GE O T E C H B H P L O T S - G I N T S T D U S L A B . G D T - 3 / 1 4 / 1 6 1 2 : 5 5 - C : \ U S E R S \ P U B L I C \ D O C U M E N T S \ B E N T L E Y \ G I N T \ P R O J E C T S \ 1 6 - 0 0 5 7 W I L S O N N U R S E R Y . G P J Haugo GTS 2825 Cedar Ave S Minneapolis, MN 55407 Telephone: 612-729-2959 Fax: 763-445-2238 4 inches of Aggregate Base. Silty Sand, with Gravel, brown, moist. (FILL) Sandy Lean Clay, possible Bituminous layer at about 5 feet, blackand grey, moist. (FILL) Sandy Lean Clay, black, moist to wet. (Buried Topsoil) (CL) Sandy Lean Clay, trace Gravel, light grey, wet, rather soft.(Glacial Till) (CL) Sandy Lean Clay, trace Gravel, brown with rust staining, medium to rather stiff. (Glacial Till) Bottom of borehole at 21.0 feet. AU 49 SS50 SS51 SS52 SS53 SS54 SS 55 SS56 3-5-5(10) 2-8-7(15) 2-1-3(4) 1-1-3(4) 1-3-4(7) 3-5-6 (11) 4-6-6(12) NOTES GROUND ELEVATION 896.5 ft LOGGED BY MS DRILLING METHOD Hollow Stem Auger/Split Spoon DRILLING CONTRACTOR HGTS GROUND WATER LEVELS: CHECKED BY JC DATE STARTED 3/1/16 COMPLETED 3/1/16 AT TIME OF DRILLING --- Not Encountered AT END OF DRILLING --- Not Encountered AFTER DRILLING --- Not Encountered at Cave-In Depth of 11 feet HOLE SIZE 3 1/4 inches FINES CONTENT (%) 20 40 60 80 20 40 60 80 PL LLMC DE P T H (f t ) 0 5 10 15 20 GR A P H I C LO G MATERIAL DESCRIPTION SA M P L E T Y P E NU M B E R RE C O V E R Y % (R Q D ) BL O W CO U N T S (N V A L U E ) PO C K E T P E N . (t s f ) DR Y U N I T W T . (p c f ) SPT N VALUE 20 40 60 80 PAGE 1 OF 1 BORING NUMBER SB-7 CLIENT Gonyea Homes PROJECT NUMBER 16-0057 PROJECT NAME Wilson Nursery PROJECT LOCATION Chanhassen, MN GE O T E C H B H P L O T S - G I N T S T D U S L A B . G D T - 3 / 1 4 / 1 6 1 2 : 5 5 - C : \ U S E R S \ P U B L I C \ D O C U M E N T S \ B E N T L E Y \ G I N T \ P R O J E C T S \ 1 6 - 0 0 5 7 W I L S O N N U R S E R Y . G P J Haugo GTS 2825 Cedar Ave S Minneapolis, MN 55407 Telephone: 612-729-2959 Fax: 763-445-2238 Silty Sand, with Gravel, brown, moist. (Fill) (CL) Sandy Lean Clay, trace Gravel, with Cobbles below 15 feet, brown with rust staining, stiff to very stiff. (Glacial Till) Bottom of borehole at 21.0 feet. AU 57 SS58 SS59 SS60 SS61 SS62 SS 63 SS64 3-6-8(14) 4-8-9(17) 6-8-10(18) 4-8-8(16) 4-6-8(14) 5-8-9 (17) 19-50/5" NOTES GROUND ELEVATION 901.7 ft LOGGED BY MS DRILLING METHOD Hollow Stem Auger/Split Spoon DRILLING CONTRACTOR HGTS GROUND WATER LEVELS: CHECKED BY JC DATE STARTED 3/2/16 COMPLETED 3/2/16 AT TIME OF DRILLING --- Not Encountered AT END OF DRILLING --- Not Encountered AFTER DRILLING --- Not Encountered at Cave-In Depth of 16 feet HOLE SIZE 3 1/4 inches FINES CONTENT (%) 20 40 60 80 20 40 60 80 PL LLMC DE P T H (f t ) 0 5 10 15 20 GR A P H I C LO G MATERIAL DESCRIPTION SA M P L E T Y P E NU M B E R RE C O V E R Y % (R Q D ) BL O W CO U N T S (N V A L U E ) PO C K E T P E N . (t s f ) DR Y U N I T W T . (p c f ) SPT N VALUE 20 40 60 80 PAGE 1 OF 1 BORING NUMBER SB-8 CLIENT Gonyea Homes PROJECT NUMBER 16-0057 PROJECT NAME Wilson Nursery PROJECT LOCATION Chanhassen, MN GE O T E C H B H P L O T S - G I N T S T D U S L A B . G D T - 3 / 1 4 / 1 6 1 2 : 5 5 - C : \ U S E R S \ P U B L I C \ D O C U M E N T S \ B E N T L E Y \ G I N T \ P R O J E C T S \ 1 6 - 0 0 5 7 W I L S O N N U R S E R Y . G P J Haugo GTS 2825 Cedar Ave S Minneapolis, MN 55407 Telephone: 612-729-2959 Fax: 763-445-2238 >> Sandy Lean Clay, black, wet. (Topsoil) (CL) Sandy Lean Clay, trace Gravel, brown, moist, rather stiff to very stiff. (Glacial Till) (CL) Sandy Lean Clay, trace Gravel, with Sand seams, brown, moist, very stiff. (Glacial Till) (SM) Silty Sand, mostly fine to medium grained, trace Gravel,brown, moist, medium dense. (Glacial Till) (CL) Sandy Lean Clay, trace Gravel, brown, moist, stiff.(Glacial Till) Bottom of borehole at 21.0 feet. AU 65 SS66 SS67 SS68 SS69 SS70 SS 71 SS72 2-6-6(12) 5-5-6(11) 4-5-7(12) 5-5-10(15) 6-11-10(21) 7-11-13 (24) 5-7-9(16) NOTES GROUND ELEVATION 918.5 ft LOGGED BY MS DRILLING METHOD Hollow Stem Auger/Split Spoon DRILLING CONTRACTOR HGTS GROUND WATER LEVELS: CHECKED BY JC DATE STARTED 3/2/16 COMPLETED 3/2/16 AT TIME OF DRILLING --- Not Encountered AT END OF DRILLING --- Not Encountered AFTER DRILLING --- Not Encountered at Cave-In Depth of 17 feet HOLE SIZE 3 1/4 inches FINES CONTENT (%) 20 40 60 80 20 40 60 80 PL LLMC DE P T H (f t ) 0 5 10 15 20 GR A P H I C LO G MATERIAL DESCRIPTION SA M P L E T Y P E NU M B E R RE C O V E R Y % (R Q D ) BL O W CO U N T S (N V A L U E ) PO C K E T P E N . (t s f ) DR Y U N I T W T . (p c f ) SPT N VALUE 20 40 60 80 PAGE 1 OF 1 BORING NUMBER SB-9 CLIENT Gonyea Homes PROJECT NUMBER 16-0057 PROJECT NAME Wilson Nursery PROJECT LOCATION Chanhassen, MN GE O T E C H B H P L O T S - G I N T S T D U S L A B . G D T - 3 / 1 4 / 1 6 1 2 : 5 5 - C : \ U S E R S \ P U B L I C \ D O C U M E N T S \ B E N T L E Y \ G I N T \ P R O J E C T S \ 1 6 - 0 0 5 7 W I L S O N N U R S E R Y . G P J Haugo GTS 2825 Cedar Ave S Minneapolis, MN 55407 Telephone: 612-729-2959 Fax: 763-445-2238 Sandy Lean Clay, trace Roots, dark brown, moist to wet. (Topsoil) (CL) Sandy Lean Clay, trace Gravel, brown with rust staining,moist to wet, rather stiff to stiff. (Glacial Till) Bottom of borehole at 21.0 feet. AU 73 SS74 SS75 SS76 SS77 SS78 SS 79 SS80 3-4-5(9) 3-5-7(12) 3-5-6(11) 5-6-7(13) 3-5-6(11) 3-5-7 (12) NOTES GROUND ELEVATION 933.3 ft LOGGED BY MS DRILLING METHOD Hollow Stem Auger/Split Spoon DRILLING CONTRACTOR HGTS GROUND WATER LEVELS: CHECKED BY JC DATE STARTED 3/2/16 COMPLETED 3/2/16 AT TIME OF DRILLING --- Not Encountered AT END OF DRILLING --- Not Encountered AFTER DRILLING --- Not Encountered HOLE SIZE 3 1/4 inches FINES CONTENT (%) 20 40 60 80 20 40 60 80 PL LLMC DE P T H (f t ) 0 5 10 15 20 GR A P H I C LO G MATERIAL DESCRIPTION SA M P L E T Y P E NU M B E R RE C O V E R Y % (R Q D ) BL O W CO U N T S (N V A L U E ) PO C K E T P E N . (t s f ) DR Y U N I T W T . (p c f ) SPT N VALUE 20 40 60 80 PAGE 1 OF 1 BORING NUMBER SB-10 CLIENT Gonyea Homes PROJECT NUMBER 16-0057 PROJECT NAME Wilson Nursery PROJECT LOCATION Chanhassen, MN GE O T E C H B H P L O T S - G I N T S T D U S L A B . G D T - 3 / 1 4 / 1 6 1 2 : 5 5 - C : \ U S E R S \ P U B L I C \ D O C U M E N T S \ B E N T L E Y \ G I N T \ P R O J E C T S \ 1 6 - 0 0 5 7 W I L S O N N U R S E R Y . G P J Haugo GTS 2825 Cedar Ave S Minneapolis, MN 55407 Telephone: 612-729-2959 Fax: 763-445-2238 Descriptive Terminology of Soil Standard D 2487 -00 Classification of Soils for Engineering Purposes (Unified Soil Classification System) "I~ DO o> Co a r s e - g r a i n e d S mo r e t h a n 5 0 % r e t a i No . 2 0 0 s i e v e •.c £ *~ O OJ Q}IS) f •>i i» -S £g ™ O (MMd£oZ Lg irj Criteria for Assigning Group Symbols and Group Names Using Laboratory Tests a Gravels More than 50% of coarse fraction retained on No 4 sieve Sands 50% or more of coarse fraction passes No 4 sieve Silts and Clays Liquid irmil less than 50 Silts and clays Liquid limit 50 or more Highly Organic Soils Clean Gravels 5% or less fines e Gravels with Fines More than 12°'C fines * Clean Sands 5% or less fines ' Sands with Fines More than 12%' Inorganic Organic Inorganic Organic Cb^4anO 1< Cr < 3C Cu<4 and/or 1 >Ct>3c Fines classify as ML or MH Fines classify as CL or CH Cu^6and l <.C( ^3C Ca<6and/or 5 i CC>3C Fines classify as ML or MH Fines classify as CL or CH PI > 7 and plots on or above 'A' line' PI < 4 or plots below "A" line1 Liquid limit- oven dried ^ n 7(_ Liquid limit - not dried PI plots on or above "A" line PI plots below 'A~ line Liquid limit - oven dried n _ic Liquid limit - not dried Primarily organic matter, dark in color and organic odor Soils Classification Group Symbol GW GP GM GC SW SP SM sc CL ML OL OL CH MH OH OH PT Group Name " Wen-graded grave! • Poorly graded gravel - Sity gravel a">' Clayey gravel3'5 Well-graded sand " Poorfy graded sand " Silly sand 'g' Clayev sand "f! Lean ciay L Sill ' Organic clay ' Organic silt " " : Fat clay * " Elastic silt ' " Organic clay ; Organic silt ' " ' Peat Particle Size Identification Boulders Cobbles Gravel Sand Silt Clay . . . over 12" 3" to 12" 3/4' to 3" No 4 to No 10 . . No 10 to No 40 No 4010NO 200 below "A" line on or above "A" line Based on !he material passing the 3-in I'TSmnvi sieve If field sample contained ccbbies o' bouioers or both ado <= 3 DK;D:C c = (DM)' cobbles or boulders Of t*oth lo group d If soil contains^l5% sand ooo1 A-.thsand' to group namg e Gravels wrtn £ lc 1 2% fines require dual symbols GW-GM \veii-graded gravei with silt GW-GC well-graded gravel with clay GP-GM ooorly graflea gravel with sill GP-GC poorly graced gravel with clay ( If tines Classify as CL-ML jse flual symbol GC-GM or SC-SM g tt fines are organic add will1 organic fines !o group name fi If soil contains i 15% g'svel add 'with gravel" to group name l Sands *t:n 5 to 12% fines legume Ouar symbols SW-SM we'l-graded sand with sitl SW-SC weil-g'aded sanO with ciay SP-SM poorly gfadect sand with sit! SP-SC poorly giadsd sano wrth clay j BAttefDerg limits pio! m haiched area soihsaCL-ML silly oay k If soil contains lGlo29'A plus No 2X add' v.i!h sand" or -with gravel' wtiichevens predominant I Hsoilcon;airi=i30%piuSNo 200 predominantly sanO add'sanay logroupname m ff so*! contains S; 30% plus Nc 200 pfedoi^riantiy gravei ado 'gravelly togroupnarne n PI ^ A ano plots on or above 'A" line o. PI < 4 or plots Delo* "A" line p PI plots on 01 above A' line q PI p!o;s beiow A hie GO 50 — 40 X 1 30 *u 2 CL 20 v^n-%£/S P7^ ML or OL ^* MH or OH 17 10 16 20 30 40 50 60 70 80 90 100 Liquid Limit (LL) Laboratory Tests 110 DO WD MC LL PL PI P200 Dry density pcf Wet density, pel Natural moisture content Liqiuid fimit. % Plastic iimi! % Plasticity index. =.t Vi passmg 200 sieve OC Organic content % S Percent of saturation. S-t SG Specific gravity C Cohesion, psf 0 Angle of internal friction qu Unconfmed compressive strength. qp Pocket penetrometer strength, tsf psf Relative Density of Cohesionless Soils Very loose .. 0104 BPF Loose 5 to 10 BPf Medium dense 11to30BPF Dense 31 to 50 BPF Very dense over 50 BPF Consistency of Cohesive Soils Very soft Dto1 BPF Soft 2 to 3 BPF Rather soft 4 to 5 BPF Medium 6!o8BPF Rather stiff 9 to 12 BPF Si'ff 13to16BPF Verysliff ... 17to30BPF Hard . . over 30 BPF Drilling Notes Standard penetration lest borings were advanced by 3 1/4" or 6 1/4' ID hollow-stem augers unless noted otherwise. Jetlmg water was used to clean out auger prior to sampling only where indicated on logs Standard penetration test borings are designated by the prefix "ST" (Split Tube) All samples were taken with the standard 2' OD split-tube sampler except where noted Power auger borings were advanced by 4 or 6" diameler continuous- flight, solid-stem augers Soti classifications and strata depths were in- ferred from disturbed samples augered to the surface and are. therefore, somewha! approximate Power auger borings are designated by the prefix "B." Hand auger borings were advanced manually with a 1 1/2" or 3 1/4" diameler auger and were limited lo the depth from which the auger coutd be manually withdrawn. Hand auger borings are indicated by the prefix •H ' BPF: Numbers indicate blows per foot recorded in standard penetration test, also known as "N" value. The sampler was set 6' into undisturbed soil below the hollow-slem auger Driving resistances were then counted for second and thtrd 6" increments and added to get BPF Where they differed significantly, they are reported in the following form 2/12 for the second and third 6" increments, respectively. WH: WH indicates the sampler penetrated soil under weight of hammer and rods alone driving not required WR: WR indicates the sampler penetrated soil under weight of rods alone hammer weight and driving not required TW indicates trvn-wailed (undisturbed) tube sample Note: All tests were run in general accordance with applicable ASTM standards Rev