15-0878 Bandimere Park - Geo Report January 19, 2016 HGTS Project Number: 15-0878 Mr. Paul Cherne, P.E. Pioneer Engineering 2422 Enterprise Drive Mendota Heights, MN 55120 RE: Geotechnical Exploration Report, Proposed Bandimere Park Court and Parking Lot Improvements, 9405 Great Plains Boulevard, Chanhassen, MN Dear Mr. Cherne: We have completed the geotechnical exploration report for the proposed Bandimere Park court and parking lot improvements at 9405 Great Plains Boulevard in Chanhassen, Minnesota. A brief summary of our results and recommendations is presented below. Additional details regarding our procedures, results and recommendations follow in the attached geotechnical exploration report. Five soil borings were completed for this project, each extending to a nominal depth up to 15 feet below the ground surface. The borings found topsoil, clayey fill and buried top to depths ½ foot to 16 feet of fill generally over native clay till soils. Portions of the fill soils were dark brown to black in color and had variable penetration resistance values (N-Values). Both the existing fill soils and topsoil are judged to be potentially compressible. Groundwater was encountered in SB-4 at a depth of 11 ½ feet while drilling and not encountered after drilling to the cave in depth of 11 feet. Groundwater was not encountered in the remaining four soil borings while drilling or after drilling. The existing fill soils and topsoil are judged to be potentially compressible and generally unsuitable for pavement support. The underlying alluvial and clay till soils appear generally suitable for pavement support. We anticipate soil corrections consisting of removing the existing fill and topsoil and placing engineered fill to establish pavement grades. SB-4 performed at the east car parking lot entrance encountered existing fill soils which extended deeper than 16 feet and a portion of the car parking lot will likely be supported by existing fill soils. Thank you for the opportunity to assist you on this project. If you have any questions or need additional information please contact John Carlson at 612-979-3542 or Joe Westphal at 612-269-4027. Sincerely, Haugo GeoTechnical Services John T. Carlson, P.E. Joe Westphal, P.E. Senior Engineer Project Engineer GEOTECHNICAL EXPLORATION REPORT PROJECT: Proposed Bandimere Park Court and Parking Lot Improvements 9405 Great Plains Boulevard Chanhassen, Minnesota PREPARED FOR: Pioneer Engineering 2422 Enterprise Drive Mendota Heights, MN 55120 PREPARED BY: Haugo GeoTechnical Services LLC 2825 Cedar Avenue S Minneapolis, MN 55407 Haugo GeoTechnical Services Project: 15-0878 January 19, 2016 I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Registered Professional Engineer under the laws of the State of Minnesota. Joe Westphal, P.E. Project Engineer License Number 49833 Expires June, 2016 TABLE OF CONTENTS 1.0 INTRODUCTION 1 1.1 Project Description 1 1.2 Purpose 1 1.3 Site Description 1 1.4 Scope of Services 1 1.5 Documents Provided 2 1.6 Locations and Elevations 2 2.0 FIELD PROCEDURES 2 3.0 RESULTS 3 3.1 Soil Conditions 3 3.2 Groundwater 3 3.3 Laboratory Testing 3 3.4 OSHA Soil Classification 4 4.0 DISCUSSION AND RECOMMENDATIONS 4 4.1 Proposed Construction 4 4.2 Discussion 4 4.3 Paved Court & Parking Lot Preparation 5 4.4 Pavement Recommendations 6 4.5 Utilities 7 5.0 CONSTRUCTION CONSIDERATIONS 8 5.1 Excavation 8 5.2 Observations 8 5.3 Backfill and Fills 8 5.4 Testing 8 5.5 Winter Construction 8 6.0 PROCEDURES 9 6.1 Soil Classification 9 6.2 Groundwater Observations 9 7.0 GENERAL 9 7.1 Subsurface Variations 9 7.2 Review of Design 9 7.3 Groundwater Fluctuations 10 7.4 Use of Report 10 7.5 Level of Care 10 APPENDIX 11 Boring Location Sketch, Figure 1 GPS Boring Locations, Figure 2 Soil Boring Logs, SB-1 thru SB-5 Descriptive Terminology 1 1.0 INTRODUCTION 1.1 Project Description The City of Chanhassen is proposing to construct a concrete pavement hockey/pickleball court, bituminous pavement 28 car stall parking lot and bituminous trails at Bandimere Park in Chanhassen, Minnesota. Associated with the improvements is the construction of underground utilities and storm water ponds. Pioneer Engineering requested a geotechnical exploration to evaluate the suitability of site soil conditions to support the proposed pavements and to provide recommendations for site development. 1.2 Purpose The purpose of this geotechnical exploration was to characterize subsurface soil and groundwater conditions and provide recommendations for site development. 1.3 Site Description The site is situated east of the access road off Great Plains Boulevard to Bandimere Park, west of a large grass field and north of a car parking lot. Based on a review of historical aerial photographs, a building once existing on the area that is proposed to be the park area, The existing structures were recently removed from the southeast corner of the site, prior to our site work. A gas line runs southeast to northwest across the center of the site. The property is generally open, grass covered and relatively flat. The ground surface elevation at our soil boring locations ranged from about 912 to 914 feet mean sea level. 1.4 Scope of Services Our services were authorized by Pioneer Engineer and performed in accordance with HGTS Proposal #15-0878, dated December 7, 2015 and under the terms of our General Conditions. Our scope of services was limited to the following tasks:  Completing five (5) standard penetration test soil borings, each to a nominal depth of 10 to 15 feet.  GPS soil boring locations and elevations.  Visually/manually classify samples recovered from the soil borings.  Performing laboratory testing on select soil samples.  Preparing soil boring logs describing the materials encountered and the results of groundwater level measurements.  Preparing an engineering report describing soil and groundwater conditions, and providing recommendations for site development. 2 1.5 Documents Provided We were provided with a concept plan of the court and parking lot improvements prepared by the City of Chanhassen, labeled review and dated May 13, 2015. The concept plan indicates a 80 feet by 176 feet concrete pavement hockey/pickleball court, 65 feet by 90 feet grass skate area, 28 car stall bituminous pavement parking lot with two entrances, segments of bituminous trails and a bituminous shelter pad. Grading or utility plans were not available at this time. 1.6 Locations and Elevations The boring locations were selected by jointly by Haugo GeoTechnical Services (HGTS) and Pioneer Engineering. The approximate location of the soil borings are shown on Figure 1, “Soil Boring Location Sketch”, in the Appendix. The sketch was prepared by HGTS using an aerial photograph from the Hennepin County GIS website as a base. Ground surface elevations at the boring locations were obtained by HGTS using GPS measuring equipment. Elevations were based on MN County Coordinates System mean sea level using the GEOID09 (Conus) model. GPS coordinates at the boring locations are provided in Figure 2 in the Appendix. 2.0 FIELD PROCEDURES Five (5) standard penetration test borings were performed on December 22, 2015 by HGTS with a rotary drilling rig, using continuous flight augers to advance the boreholes. Representative samples were obtained from the borings, using the split-barrel sampling procedures in general accordance with ASTM Specification D-1586. In the split-barrel sampling procedure, a 2-inch O.D. split-barrel spoon is driven into the ground with a 140- pound hammer falling 30 inches. The number of blows required to drive the sampling spoon the last 12 inches of an 18-inch penetration is recorded as the standard penetration resistance value, or "N" value. The results of the standard penetration tests are indicated on the boring log. The samples were sealed in containers and provided to HGTS for testing and soil classification. A field log of each boring was prepared by the HGTS drill crew. The logs contain visual classifications of the soil materials encountered during drilling, as well as the driller's interpretation of the subsurface conditions between samples and water observation notes. The final boring logs included with this report represent an interpretation of the field logs and include modifications based on visual/manual method observation of the samples. The soil boring logs, general terminology for soil description and identification, and classification of soils for engineering purposes are also included in the appendix. The soil boring logs identify and describe the materials encountered, the relative density or consistency based on the Standard Penetration resistance (N-value, “blows per foot”) and groundwater observations. 3 The strata changes were inferred from the changes in the samples and auger cuttings. The depths shown as changes between strata are only approximate. The changes are likely transitions, variations can occur beyond the location of the boring. 3.0 RESULTS 3.1 Soil Conditions Soil borings 1 and 5 encountered approximately 7 and soil boring 4 encountered greater than 16 feet of previously placed fill soils. The fill soils consist mainly of dark brown, grey and/or black sandy lean clay, clayey sand and/or silty sand. Penetration resistance values (N-Values), shown as blows per foot (bpf) on the boring log, within the existing fill soils were variable and ranged from 4 to 10 bpf. Underlying the fill soils at soil boring 5 or at the surface of soil borings 2 and 3, approximately 1 to 4 feet of clayey topsoil was encountered. The topsoil was dark brown to black in color and judged to be slightly organic. Underlying the existing fill soils and/or topsoil, soil borings 1 thru 3 and 5 generally encountered native alluvial lean clay and/or sandy lean clay glacial till soils extending to the termination depths of the soil borings. The N-values indicate the clays to be generally medium to stiff. 3.2 Groundwater Groundwater was encountered in soil boring SB-4 at a depth of 11 ½ feet (corresponding to an elevation of about 902) while drilling and not encountered after drilling to the cave in depth of 11 feet. At the other four soil borings groundwater was not encountered while drilling or after drilling to the cave in depths of 8 to 13 feet. The approximate water level of Lake Riley to the east of the site is about 875 feet, The groundwater encountered at boring SB-4 appears to be perched groundwater. However, the borings were completed in clayey soils and it may take several hours or days for groundwater to reach its hydrostatic level in an open borehole. Groundwater monitoring wells or piezometers in conjunction with deeper soil borings would be required to more accurately determine water levels. Seasonal and annual fluctuations in the groundwater levels should be expected. 3.3 Laboratory Testing Laboratory moisture content tests were performed on selected samples recovered from the soil borings. Table 1 below summarizes the results of the laboratory tests. Results of the laboratory moisture content tests are also shown on the boring logs adjacent to the sample tested. 4 Table 1. Summary of Laboratory Tests Boring Number Sample Number Depth (feet) Moisture Content (%)* SB-1 S-25 7 ½ 22 SB-2 S-17 5 23 ½ SB-3 S-3 5 20 ½ SB-4 S-9 2 ½ 17 SB-5 S-31 5 21 *Moisture contents tests were rounded to the nearest ½ percent 3.4 OSHA Soil Classification The existing fill soils and glacial till soils encountered in the borings generally correspond to the ASTM Classifications CL. The soils identified in the borings will generally be Type B soils under Department of Labor Occupational Safety and Health Administration (OSHA) guidelines. 4.0 DISCUSSION AND RECOMMENDATIONS 4.1 Proposed Construction The City of Chanhassen is proposing to construct a concrete pavement hockey/pickleball court, bituminous pavement 28 car stall parking lot and bituminous trails at Bandimere Park in Chanhassen, Minnesota. Associated with the improvements is the construction of underground utilities and storm water ponds. Grading or utility plans were not available at this time. We have attempted to describe our understanding of the project. If the design or location of the proposed pavements change, we should be informed. Additional analyses and revised recommendations may be necessary. 4.2 Discussion Soil borings 1, 2 and 5 were performed in the proposed concrete pavement court area and encountered about 1 ½ to 9 feet of fill and/or topsoil over alluvial clays and/or clay till soils. Soil borings 3 and 4 performed in the proposed bituminous pavement parking lot encountered about 4 feet of topsoil over alluvial/clay till soils at soil boring 3 and greater than 16 feet of fill soils at soil boring 4. Portions of the fill soils were dark brown to black in color and had variable penetration resistance values (N-Values). The existing fill soils and topsoil are judged to be potentially compressible and generally unsuitable for pavement support. The underlying alluvial and clay till soils appear generally suitable for pavement support. We anticipate soil corrections consisting of removing the existing fill and topsoil and placing engineered fill to establish pavement grades. Soil boring 4 performed at the east car parking lot entrance encountered existing fill soils which extended to a depth of 16 feet and a portion of the car parking lot will likely be 5 supported by the existing fill soils. There is a risk of pavement settlement due to consolidation of the existing fill soils in this area. Groundwater was encountered in soil boring 4 at a depth of 11 ½ feet while drilling and not encountered after drilling to the cave in depth of 11 feet. At the other four soil borings groundwater was not encountered while drilling or after drilling to cave in depths of 8 to 13 feet. If pockets of groundwater are encountered we anticipate the volume to be small and able to be removed with sumps or pumps. 4.3 Paved Court & Parking Lot Preparation Excavations A structure formerly existed in the southeast corner of the property. We recommend all remnants of the former structure including footings, floor slabs, foundation walls and underground utilities, if encountered, be removed from within the proposed pavement and oversize areas. Likewise we recommend that all vegetation, existing fill soils, topsoil and soft clays be removed from the proposed pavement and oversize areas. Table 2 below summarizes the anticipated excavation depths at the boring locations. Excavation depths may vary and could be deeper. Table 2. Anticipated Grading Excavation Depths Boring Number Location Measured Surface Elevation (feet) Anticipated Excavation Depth (feet)* Anticipated Excavation Elevation (feet)* SB-1 Court 913.2 7 906 SB-2 Court 914.3 1 ½ 913 SB-3 Parking Lot 912.7 4 908 ½ SB-4 Parking Lot 913.3 5 908 ½ SB-5 Court 912.6 9 903 ½ *Excavation depths and elevation were rounded to the nearest ½ foot. Area of Soil Boring 4 Boring SB-4 performed at the east car parking lot entrance encountered existing fill soils which extended deeper than 16 feet and a portion of the parking lot will likely be supported by existing fill soils. Due to the N-Value of 4 near the surface, we recommend reworking a minimum of the upper 3 feet of the subgrade. Additionally, to further evaluate the suitability of the existing fill soils, if necessary, tests pits could be performed prior to or at the time of construction to further evaluate the quality of the fill in the pavement areas. Compaction tests could be performed on the fill within test pits confirm compaction is a minimum of 95 percent of Standard Proctor. Oversizing In areas where the excavations extend below the proposed pavement elevations, the excavation requires oversizing. We recommend the perimeter of the excavation be extended a foot outside the proposed footprint for every foot below pavement grade (1H:1V oversizing). The purpose of the oversizing is to provide lateral support of the pavements. Fill and backfill placed on slopes must be “benched” into the underlying suitable soil to reduce the potential for slip planes to develop between the fill and underlying soil. We 6 recommend “benching” or excavating into the slope at 5 feet vertical intervals to key the fill into the slope. We recommend each bench be a minimum of 10 feet wide. Fill Material Fill required to attain site grades may consist of any debris-free, non-organic mineral soil. Portions of the removed existing fill soils could be reused as engineered fill but will likely require moisture conditioning (drying). Constructing the pavements with a 2 foot thick sand subbase would provide a more stable and less frost susceptible pavement subgrade. We recommend using sand with less than 12% passing the #200 sieve, such as MN/DOT 3149.2B2 (Select Granular Borrow). If the sand sub-base is used we recommend the sub-base extend to 2 feet beyond the outside edges of the curbs/pavements for frost and drainage uniformity. Sand layers outside the pavements/curbs should be capped with slow draining soil to reduce surface water infiltration. If a sand sub-base is used in the pavement areas, drainpipes (finger drains) should be installed to remove infiltrating water. The finger drains should be connected to the catch basins. The slope of the bottom of the sub-cut should be such that water is directed to the drainage areas. The sub-cut bottom should not include depressions that can act as reservoirs for water collection. Backfilling We recommend that engineered fill placed to establish pavement grades be compacted to a minimum of 95 percent of its standard Proctor maximum dry density. The upper 3 feet of fill and backfill should be compacted to a minimum of 100 percent of its standard Proctor maximum dry density. We recommend compacting the backfill at moisture contents within a range of 1 percentage point above and 3 percentage points below its optimum moisture content. Granular fill classified as SP or SP-SM can be placed within 65 percent to 105 percent of its optimum moisture content as determined by the standard Proctor. All fill should be placed in thin lifts and be compacted with a large self-propelled vibratory compactor operating in vibratory mode. 4.4 Pavement Recommendations R-Value testing was beyond the scope of this project. The soil borings generally encountered existing fill and clay till soils consisting of predominantly of sandy lean clay soils near the surface corresponding to the ASTM Classifications CL. We assume the sandy lean clays will mainly comprise the pavement subgrades and recommend using an R-Value of 12 for pavement design. We recommend a light duty bituminous pavement section for the car parking lot consist of 1 ½ inches of bituminous wear, 2 ½ inches of bituminous base and 8 inches of aggregate base and the bituminous trail/bituminous shelter pad consist of 3 inches of bituminous wear and 6 inches of aggregate base. We recommend the concrete pavement section for the hockey rink/pickleball courts be at least 6 inches thick. We recommend the concrete be reinforced with rebar and have control joints with a maximum 10 foot by 10 foot grid. Additionally, we recommend a minimum of 6 7 inches of sub-base material be placed below the rink/concrete slab, consisting of imported Sand subgrade meeting MN/DOT specification 3138 (Class 5). Prior to placing the aggregate base (Class 5) we recommend observing a test roll of the subgrade soils with a loaded tandem truck to identify soft, weak, loose or unstable areas that may require additional subcuts. We recommend aggregate base meeting MN/DOT specification 3138 for Class 5 aggregate base. We recommend the aggregate base be compacted to 100 percent of its maximum standard Proctor dry density. We recommend that the bituminous wear and base courses meet the requirement of MN/DOT specification 2360. We recommend the bituminous pavements be compacted to at least 92% of the maximum theoretical density. The hockey rink/pickleball courts will be a concrete slab and the car parking lot will include concrete curb and gutter. We recommend specifying concrete that has a minimum 28 day compressive strength of 3,900 psi. We recommend specifying 5 to 8 percent entrained air for exposed concrete to provide resistance to freeze-thaw deterioration. We recommend slump, air content and compressive strength testing of Portland cement concrete. 4.5 Utilities We anticipate new underground storm sewer utilities will be installed as part of the project. We anticipate that the utilities will be supported by engineered fill and/or glacial till soils which in our opinion are suitable for pipe support. We recommend removing all topsoil, existing fill soils, soft clays or other unsuitable soils, if encountered, beneath utilities prior to utility placement. We recommend bedding material be thoroughly compacted around the pipes. We recommend trench backfill above the pipes be compacted to a minimum of 95 percent beneath pavements, the exception being within 3 feet of the proposed pavement subgrade, where 100 percent of standard Proctor density is required. In landscaped areas we recommend a minimum compaction of 90 percent. Groundwater only encountered in soil boring 4 at a depth of 11 ½ feet while drilling. This groundwater appears to have been perched with a sand seams of the soil. If groundwater is encountered during utility installations, we assume the volume of water will be relatively small and able to be removed with sumps or pumps 8 5.0 CONSTRUCTION CONSIDERATIONS 5.1 Excavation The existing fill soils and glacial till soils encountered in the borings generally correspond to the ASTM Classifications CL. The soils identified in the borings will generally be Type B soils under Department of Labor Occupational Safety and Health Administration (OSHA) guidelines. Temporary excavations should be constructed at a minimum of 1 foot horizontal to every 1 foot vertical within excavations. Slopes constructed in this manner may still exhibit surface sloughing. If site constraints do not allow the construction of slopes with these dimensions then temporary shoring may be required. 5.2 Observations A geotechnical engineer or qualified engineering technician should observe the excavation subgrade to evaluate if the subgrade soils are similar to those encountered in the borings and adequate to support the proposed construction. 5.3 Backfill and Fills Site soils that will be excavated and reused as backfill and fill appear to be above their assumed optimum moisture content. We anticipate it will be necessary to moisture condition (dry) these soils to achieve the recommended compaction. We recommend that fill and backfill be placed in lifts not exceeding 4 to 12 inches, depending on the size of the compactor and materials used. 5.4 Testing We recommend density tests of backfill and fills placed during construction of the pavements. Samples of the proposed materials should be submitted to our laboratory prior to placement for evaluation of their suitability and to determine their optimum moisture content and maximum dry density (Standard Proctor). 5.5 Winter Construction If site grading and construction is anticipated to proceed during cold weather, all snow and ice should be removed from cut and fill areas prior to additional grading and placement of fill. No fill should be placed on frozen soil and no frozen soil should be used as fill or backfill. Concrete delivered to the site should meet the temperature requirements of ASTM and/or ACI. Concrete should not be placed on frozen soil. Concrete should be protected from freezing until the necessary strength is obtained. Frost should not be permitted to penetrate below the footings. 9 6.0 PROCEDURES 6.1 Soil Classification The drill crew chief visually and manually classified the soils encountered in the borings in general accordance with ASTM D 2488, “Description and Identification of Soils (Visual- Manual Procedure)”. Soil terminology notes are included in the Appendix. The samples were returned to our laboratory for review of the field classification by a geotechnical engineer. Samples will be retained for a period of 30 days. 6.2 Groundwater Observations Immediately after taking the final samples in the bottom of the borings, the hole was checked for the presence of groundwater. Again, at the end of the drilling day, the borings were re-checked for the presence of groundwater with the levels and time delay being noted on the boring logs. 7.0 GENERAL 7.1 Subsurface Variations The analyses and recommendations presented in this report are based on data obtained from a limited number of soil borings. Variations can occur away from the borings, the nature of which may not become apparent until additional exploration work is completed or construction is conducted. A reevaluation of the recommendations in this report should be made after performing on-site observations during construction to note the characteristics of any variations. The variations may result in additional foundation costs and it is suggested that a contingency be provided for this purpose. It is recommended that we be retained to perform the observation and testing program during construction to evaluate whether the design is as expected, if any design changes have affected the validity of our recommendations, and if our recommendations have been correctly interpreted and implemented in the designs, specifications and construction methods. This will allow correlation of the soil conditions encountered during construction to the soil borings and will provide continuity of professional responsibility. 7.2 Review of Design This report is based on the design of the proposed pavements as related to us for preparation of this report. It is recommended that we be retained to review the geotechnical aspects of the design and specifications. With the review we will evaluate whether any changes have affected the validity of the recommendations and whether our recommendations have been correctly interpreted and implemented in the design and specifications. 10 7.3 Groundwater Fluctuations We made water level measurements in the borings at the times and under the conditions stated on the boring logs. The data was interpreted in the text of this report. The period of observation was relatively short and fluctuations in the groundwater level may occur due to rainfall, flooding, irrigation, spring thaw, drainage, and other seasonal and annual factors not evident at the time the observations were made. Design drawings and specifications and construction planning should recognize the possibility of fluctuations. 7.4 Use of Report This report is for the exclusive use of the City of Chanhassen, Pioneer Engineering and their design team to use to design the proposed structures and prepare construction documents. In the absence of our written approval, we make no representation and assume no responsibility to other parties regarding this report. The data, analysis and recommendations may not be appropriate for other structures or purposes. We recommend that parties contemplating other structures or purposes contact us. 7.5 Level of Care Haugo GeoTechnical Services, LLC has used the degree of skill and care ordinarily exercised under similar circumstance by members of the profession currently practicing in this locality. No warranty expressed or implied is made. APPENDIX = Approximate Boring Location Haugo GeoTechnical Services. 2825 Cedar Ave S Minneapolis, MN 55407 Figure #: 1 Drawn By: LWM Date: 1/8/16 Scale: None HGTS Project #: 15-0878 Soil Boring Location Sketch Proposed Park Addition Bandimere Park Chanhassen, MN SB-2 SB-1 SB-4 SB-3 SB-5 Structure(s) were removed at the time of our Exploration HGTS# 15-0878 Figure 2: GPS Boring Locations Referencing Minnesota County Coordinates Basis – Carver County (GEOID09 Conus model). Boring Number Elevation (US Survey Feet) Northing Coordinate Easting Coordinate SB-1 913.22 172175.49 559758.18 SB-2 914.27 172038.96 559715.03 SB-3 912.73 172072.24 559447.27 SB-4 913.34 172020.88 559568.02 SB-5 912.60 172154.66 559665.89 Sandy Lean Clay, trace Gravel, dark brown and dark grey, moist to wet. (FILL) (CL) Sandy Lean Clay, trace Gravel, brown with rust stains, moistto wet, rather stiff. (Glacial Till) Bottom of borehole at 16.0 feet. AU22 SS 23 SS 24 SS 25 SS 26 SS 27 SS 28 3-5-4 (9) 3-6-4 (10) 2-5-6 (11) 3-4-6 (10) 3-4-7 (11) 2-5-6 (11) NOTES GROUND ELEVATION 913.2 ft MSL LOGGED BY CP DRILLING METHOD Hollow Stem Auger/Split Spoon DRILLING CONTRACTOR HGTS GROUND WATER LEVELS: CHECKED BY PG DATE STARTED 12/22/16 COMPLETED 12/22/16 AT TIME OF DRILLING --- Not Encountered. AT END OF DRILLING --- Not Encountered. AFTER DRILLING --- Not Encountered at Cave-In Depth of 12 1/2 Feet. HOLE SIZE 3 1/4 inches FINES CONTENT (%) 20 40 60 80 20 40 60 80 PL LLMC DE P T H (f t ) 0 5 10 15 GR A P H I C LO G MATERIAL DESCRIPTION SA M P L E T Y P E NU M B E R RE C O V E R Y % (R Q D ) BL O W CO U N T S (N V A L U E ) PO C K E T P E N . (t s f ) DR Y U N I T W T . (p c f ) SPT N VALUE 20 40 60 80 PAGE 1 OF 1 BORING NUMBER SB-1 CLIENT Pioneer Engineering PROJECT NUMBER 15-0878 PROJECT NAME Bandimere Park PROJECT LOCATION Chanhassen, Minnesota GE O T E C H B H P L O T S - G I N T S T D U S L A B . G D T - 1 / 1 9 / 1 6 0 8 : 1 0 - C : \ U S E R S \ P U B L I C \ D O C U M E N T S \ B E N T L E Y \ G I N T \ P R O J E C T S \ 1 5 - 0 8 7 8 B O N D I M E R E P A R K . G P J Haugo GeoTechnical Services 2825 Cedar Avenue S Minneapolis, MN 55407 Sandy Lean Clay, trace Roots, dark brown, wet. (Topsoil) (CL) Sandy Lean Clay, trace Gravel, brown with rust stains, moistto wet, medium to stiff. (Glacial Till) Bottom of borehole at 16.0 feet. AU15 SS 16 SS 17 SS 18 SS 19 SS 20 SS 21 5-4-3 (7) 5-5-5 (10) 4-5-7 (12) 3-6-8 (14) 3-4-7 (11) 3-4-5 (9) NOTES GROUND ELEVATION 914.3 ft MSL LOGGED BY CP DRILLING METHOD Hollow Stem Auger/Split Spoon DRILLING CONTRACTOR HGTS GROUND WATER LEVELS: CHECKED BY PG DATE STARTED 12/22/16 COMPLETED 12/22/16 AT TIME OF DRILLING --- Not Encountered. AT END OF DRILLING --- Not Encountered. AFTER DRILLING --- Not Encountered at Cave-In Depth of 13 Feet. HOLE SIZE 3 1/4 inches FINES CONTENT (%) 20 40 60 80 20 40 60 80 PL LLMC DE P T H (f t ) 0 5 10 15 GR A P H I C LO G MATERIAL DESCRIPTION SA M P L E T Y P E NU M B E R RE C O V E R Y % (R Q D ) BL O W CO U N T S (N V A L U E ) PO C K E T P E N . (t s f ) DR Y U N I T W T . (p c f ) SPT N VALUE 20 40 60 80 PAGE 1 OF 1 BORING NUMBER SB-2 CLIENT Pioneer Engineering PROJECT NUMBER 15-0878 PROJECT NAME Bandimere Park PROJECT LOCATION Chanhassen, Minnesota GE O T E C H B H P L O T S - G I N T S T D U S L A B . G D T - 1 / 1 9 / 1 6 0 8 : 1 0 - C : \ U S E R S \ P U B L I C \ D O C U M E N T S \ B E N T L E Y \ G I N T \ P R O J E C T S \ 1 5 - 0 8 7 8 B O N D I M E R E P A R K . G P J Haugo GeoTechnical Services 2825 Cedar Avenue S Minneapolis, MN 55407 Lean Clay with Sand, trace Roots, slightly organic, black, moist. (Topsoil) (CL-ML) Silty Clay, trace Roots, grey with rust stains, moist to wet,rather stiff. (Alluvium) (CL) Sandy Lean Clay, trace Gravel, brown with rust stains, moistto wet, very stiff to rather stiff. (Glacial Till) Bottom of borehole at 16.0 feet. AU1 SS 2 SS 3 SS 4 SS 5 SS 6 SS 7 7-9-8 (17) 5-5-4 (9) 6-9-11 (20) 3-7-9 (16) 4-6-9 (15) 2-4-6 (10) NOTES GROUND ELEVATION 912.7 ft MSL LOGGED BY CP DRILLING METHOD Hollow Stem Auger/Split Spoon DRILLING CONTRACTOR HGTS GROUND WATER LEVELS: CHECKED BY PG DATE STARTED 12/22/16 COMPLETED 12/22/16 AT TIME OF DRILLING --- Not Encountered. AT END OF DRILLING --- Not Encountered. AFTER DRILLING --- Not Encountered at Cave-In Depth of 12 Feet. HOLE SIZE 3 1/4 inches FINES CONTENT (%) 20 40 60 80 20 40 60 80 PL LLMC DE P T H (f t ) 0 5 10 15 GR A P H I C LO G MATERIAL DESCRIPTION SA M P L E T Y P E NU M B E R RE C O V E R Y % (R Q D ) BL O W CO U N T S (N V A L U E ) PO C K E T P E N . (t s f ) DR Y U N I T W T . (p c f ) SPT N VALUE 20 40 60 80 PAGE 1 OF 1 BORING NUMBER SB-3 CLIENT Pioneer Engineering PROJECT NUMBER 15-0878 PROJECT NAME Bandimere Park PROJECT LOCATION Chanhassen, Minnesota GE O T E C H B H P L O T S - G I N T S T D U S L A B . G D T - 1 / 1 9 / 1 6 0 8 : 1 0 - C : \ U S E R S \ P U B L I C \ D O C U M E N T S \ B E N T L E Y \ G I N T \ P R O J E C T S \ 1 5 - 0 8 7 8 B O N D I M E R E P A R K . G P J Haugo GeoTechnical Services 2825 Cedar Avenue S Minneapolis, MN 55407 Sandy Lean Clay, Clayey Sand and Silty Sand, dark brown, black and grey, moist to wet. (FILL) Bottom of borehole at 16.0 feet. AU8 SS 9 SS 10 SS 11 SS 12 SS 13 SS 14 3-2-2 (4) 3-4-3 (7) 3-3-5 (8) 3-4-4 (8) 1-2-3 (5) 1-2-3 (5) NOTES GROUND ELEVATION 913.3 ft MSL LOGGED BY CP DRILLING METHOD Hollow Stem Auger/Split Spoon DRILLING CONTRACTOR HGTS GROUND WATER LEVELS: CHECKED BY PG DATE STARTED 12/22/16 COMPLETED 12/22/16 AT TIME OF DRILLING 11.50 ft / Elev 901.80 ft AT END OF DRILLING --- AFTER DRILLING --- Not Encountered at Cave-In Depth of 11 Feet. HOLE SIZE 3 1/4 inches FINES CONTENT (%) 20 40 60 80 20 40 60 80 PL LLMC DE P T H (f t ) 0 5 10 15 GR A P H I C LO G MATERIAL DESCRIPTION SA M P L E T Y P E NU M B E R RE C O V E R Y % (R Q D ) BL O W CO U N T S (N V A L U E ) PO C K E T P E N . (t s f ) DR Y U N I T W T . (p c f ) SPT N VALUE 20 40 60 80 PAGE 1 OF 1 BORING NUMBER SB-4 CLIENT Pioneer Engineering PROJECT NUMBER 15-0878 PROJECT NAME Bandimere Park PROJECT LOCATION Chanhassen, Minnesota GE O T E C H B H P L O T S - G I N T S T D U S L A B . G D T - 1 / 1 9 / 1 6 0 8 : 1 0 - C : \ U S E R S \ P U B L I C \ D O C U M E N T S \ B E N T L E Y \ G I N T \ P R O J E C T S \ 1 5 - 0 8 7 8 B O N D I M E R E P A R K . G P J Haugo GeoTechnical Services 2825 Cedar Avenue S Minneapolis, MN 55407 Lean Clay, with roots and fibers, dark brown and black, moist. (Topsoil/FILL) Sandy Lean Clay, dark brown, moist to wet. (FILL) Silty Sand, trace roots, slightly organic, black, moist. (BuriedTopsoil) (CL) Lean Clay, grey, moist to wet, medium. (Alluvium) (CL) Sandy Lean Clay, trace Gravel, brown, moist to wet, ratherstiff. (Glacial Till) Bottom of borehole at 13.5 feet. AU29 SS 30 SS 31 SS 32 SS 33 SS 34 1-2-2 (4) 1-2-2 (4) 1-2-7 (9) 2-3-4 (7) 4-4-5 (9) NOTES GROUND ELEVATION 912.6 ft MSL LOGGED BY CP DRILLING METHOD Hollow Stem Auger/Split Spoon DRILLING CONTRACTOR HGTS GROUND WATER LEVELS: CHECKED BY PG DATE STARTED 12/22/16 COMPLETED 12/22/16 AT TIME OF DRILLING --- Not Encountered. AT END OF DRILLING --- Not Encountered. AFTER DRILLING --- Not Encountered at Cave-In Depth of 8 Feet. HOLE SIZE 3 1/4 inches FINES CONTENT (%) 20 40 60 80 20 40 60 80 PL LLMC DE P T H (f t ) 0 5 10 GR A P H I C LO G MATERIAL DESCRIPTION SA M P L E T Y P E NU M B E R RE C O V E R Y % (R Q D ) BL O W CO U N T S (N V A L U E ) PO C K E T P E N . (t s f ) DR Y U N I T W T . (p c f ) SPT N VALUE 20 40 60 80 PAGE 1 OF 1 BORING NUMBER SB-5 CLIENT Pioneer Engineering PROJECT NUMBER 15-0878 PROJECT NAME Bandimere Park PROJECT LOCATION Chanhassen, Minnesota GE O T E C H B H P L O T S - G I N T S T D U S L A B . G D T - 1 / 1 9 / 1 6 0 8 : 1 0 - C : \ U S E R S \ P U B L I C \ D O C U M E N T S \ B E N T L E Y \ G I N T \ P R O J E C T S \ 1 5 - 0 8 7 8 B O N D I M E R E P A R K . G P J Haugo GeoTechnical Services 2825 Cedar Avenue S Minneapolis, MN 55407 Descriptive Terminology of Soil Standard D 2487 -00 Classification of Soils for Engineering Purposes (Unified Soil Classification System) "I~ DO o> Co a r s e - g r a i n e d S mo r e t h a n 5 0 % r e t a i No . 2 0 0 s i e v e •.c £ *~ O OJ Q}IS) f •>i i» -S £g ™ O (MMd£oZ Lg irj Criteria for Assigning Group Symbols and Group Names Using Laboratory Tests a Gravels More than 50% of coarse fraction retained on No 4 sieve Sands 50% or more of coarse fraction passes No 4 sieve Silts and Clays Liquid irmil less than 50 Silts and clays Liquid limit 50 or more Highly Organic Soils Clean Gravels 5% or less fines e Gravels with Fines More than 12°'C fines * Clean Sands 5% or less fines ' Sands with Fines More than 12%' Inorganic Organic Inorganic Organic Cb^4anO 1< Cr < 3C Cu<4 and/or 1 >Ct>3c Fines classify as ML or MH Fines classify as CL or CH Cu^6and l <.C( ^3C Ca<6and/or 5 i CC>3C Fines classify as ML or MH Fines classify as CL or CH PI > 7 and plots on or above 'A' line' PI < 4 or plots below "A" line1 Liquid limit- oven dried ^ n 7(_ Liquid limit - not dried PI plots on or above "A" line PI plots below 'A~ line Liquid limit - oven dried n _ic Liquid limit - not dried Primarily organic matter, dark in color and organic odor Soils Classification Group Symbol GW GP GM GC SW SP SM sc CL ML OL OL CH MH OH OH PT Group Name " Wen-graded grave! • Poorly graded gravel - Sity gravel a">' Clayey gravel3'5 Well-graded sand " Poorfy graded sand " Silly sand 'g' Clayev sand "f! Lean ciay L Sill ' Organic clay ' Organic silt " " : Fat clay * " Elastic silt ' " Organic clay ; Organic silt ' " ' Peat Particle Size Identification Boulders Cobbles Gravel Sand Silt Clay . . . over 12" 3" to 12" 3/4' to 3" No 4 to No 10 . . No 10 to No 40 No 4010NO 200 below "A" line on or above "A" line Based on !he material passing the 3-in I'TSmnvi sieve If field sample contained ccbbies o' bouioers or both ado <= 3 DK;D:C c = (DM)' cobbles or boulders Of t*oth lo group d If soil contains^l5% sand ooo1 A-.thsand' to group namg e Gravels wrtn £ lc 1 2% fines require dual symbols GW-GM \veii-graded gravei with silt GW-GC well-graded gravel with clay GP-GM ooorly graflea gravel with sill GP-GC poorly graced gravel with clay ( If tines Classify as CL-ML jse flual symbol GC-GM or SC-SM g tt fines are organic add will1 organic fines !o group name fi If soil contains i 15% g'svel add 'with gravel" to group name l Sands *t:n 5 to 12% fines legume Ouar symbols SW-SM we'l-graded sand with sitl SW-SC weil-g'aded sanO with ciay SP-SM poorly gfadect sand with sit! SP-SC poorly giadsd sano wrth clay j BAttefDerg limits pio! m haiched area soihsaCL-ML silly oay k If soil contains lGlo29'A plus No 2X add' v.i!h sand" or -with gravel' wtiichevens predominant I Hsoilcon;airi=i30%piuSNo 200 predominantly sanO add'sanay logroupname m ff so*! contains S; 30% plus Nc 200 pfedoi^riantiy gravei ado 'gravelly togroupnarne n PI ^ A ano plots on or above 'A" line o. PI < 4 or plots Delo* "A" line p PI plots on 01 above A' line q PI p!o;s beiow A hie GO 50 — 40 X 1 30 *u 2 CL 20 v^n-%£/S P7^ ML or OL ^* MH or OH 17 10 16 20 30 40 50 60 70 80 90 100 Liquid Limit (LL) Laboratory Tests 110 DO WD MC LL PL PI P200 Dry density pcf Wet density, pel Natural moisture content Liqiuid fimit. % Plastic iimi! % Plasticity index. =.t Vi passmg 200 sieve OC Organic content % S Percent of saturation. S-t SG Specific gravity C Cohesion, psf 0 Angle of internal friction qu Unconfmed compressive strength. qp Pocket penetrometer strength, tsf psf Relative Density of Cohesionless Soils Very loose .. 0104 BPF Loose 5 to 10 BPf Medium dense 11to30BPF Dense 31 to 50 BPF Very dense over 50 BPF Consistency of Cohesive Soils Very soft Dto1 BPF Soft 2 to 3 BPF Rather soft 4 to 5 BPF Medium 6!o8BPF Rather stiff 9 to 12 BPF Si'ff 13to16BPF Verysliff ... 17to30BPF Hard . . over 30 BPF Drilling Notes Standard penetration lest borings were advanced by 3 1/4" or 6 1/4' ID hollow-stem augers unless noted otherwise. Jetlmg water was used to clean out auger prior to sampling only where indicated on logs Standard penetration test borings are designated by the prefix "ST" (Split Tube) All samples were taken with the standard 2' OD split-tube sampler except where noted Power auger borings were advanced by 4 or 6" diameler continuous- flight, solid-stem augers Soti classifications and strata depths were in- ferred from disturbed samples augered to the surface and are. therefore, somewha! approximate Power auger borings are designated by the prefix "B." Hand auger borings were advanced manually with a 1 1/2" or 3 1/4" diameler auger and were limited lo the depth from which the auger coutd be manually withdrawn. Hand auger borings are indicated by the prefix •H ' BPF: Numbers indicate blows per foot recorded in standard penetration test, also known as "N" value. The sampler was set 6' into undisturbed soil below the hollow-slem auger Driving resistances were then counted for second and thtrd 6" increments and added to get BPF Where they differed significantly, they are reported in the following form 2/12 for the second and third 6" increments, respectively. WH: WH indicates the sampler penetrated soil under weight of hammer and rods alone driving not required WR: WR indicates the sampler penetrated soil under weight of rods alone hammer weight and driving not required TW indicates trvn-wailed (undisturbed) tube sample Note: All tests were run in general accordance with applicable ASTM standards Rev