Loading...
00-118100 - Rational Method South - 360 (5-21-2019)PROJECT:11810010 YRDATE:5/21/2019VARIESBY:MSN0.013CATCHMENT/ FROM TO INC. CUM. INC INC CUM. TC TC CUM. INC. CUM. INC CUM. DIAM. GRADE MAX FULL LENGTH RIM INVERT INVERT JUMP BUILD COVER BUILD COVER DESIGN COMMENTSREACH STRUCTURE STRUCTURE A A C CA CA (LAND) (PIPE) TC I I Q Q (IN) % Q V (FT.) ELEV. (IN) (OUT) (OUT) (IN) (IN) (OUT) (OUT)362 CB-362 CBMH-3611.1231.1230.360.41 0.41010.000.39 10.005.635.63 2.31 2.3115.00 1.317.39 5.97138.09 972.00968.50 966.69 3.50 2.06 3.51 2.07 DESIGN ACCEPTABLE361 CBMH-361 FES-3600.1831.3050.340.06 0.47310.000.53 10.395.635.63 0.35 2.6615.00 0.805.77 4.66148.14 970.20966.19 965.00 4.01 2.584.00 2.56DESIGN ACCEPTABLEWATERSHED ISTORM FREQUENCY TYPE OF PIPEMANNINGS' N***FOR USE WITH MNDOT ATLAS 14 DATA***PIPE DESIGN PROFILECB206 TO CBMH205 LOCATION AREA COEFFICIENT TIME OF CONC. INTENSITY FLOW (Q) = CIA