Loading...
Bluff Creek Substation General Arrangement Plan Sheet 5-28-195 6 9 GROUND GROUNDREACTOR ~~~~~ X2 X1 X3 H0X0 H1 H2 H3 Y2 Y3Y1 X2 X1 X3 H0X0 H1 H2 H3 Y2 Y3Y1 MOBILE TRANSMOBILE TRANSMOBILE TRANS BOX SPLICE LHZ FIBER SCALE REV FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS. THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS.YOUR PERSONAL SAFETY IS PROVIDED INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT EXPRESS WRITTEN CONSENT FROM XCEL ENERGY R ISSUED BY ENGINEERING DEPT FOR: REV DATE WBS 4 REVISION DESCRIPTION REV DATE WBS 4 REVISION DESCRIPTION REV DATE WBS 4 REVISION DESCRIPTION A 5 119'-0"34'-0"34'-0"26'-0"34'-0"34'-0"31'-0"143'-0"117'-0" TRANS 3 FUTURE C B A C B A C B A C B A C B A A B C FENCE WALL FIRE A B C A B C A B C L WALK 4'-0" GATE 1 C 20'-0" DRIVEWAY L B A C OF CHASKA) UNIT #4 (BY CITY FROM SW. GR. CABLE RUNS FUTURE FDR. UNIT #2 FDRS. (BY DIVISION) EACH OF THE THREE SW. GR.. CABLES PER PHASE FOR 3-750 MCM AL. 15KV UNIT #1 FDRS. (BY DIVISION) EACH OF THE THREE SW. GR.. CABLES PER PHASE FOR 3-750 MCM AL. 15KV FENCE J B A D E F 1 2 3 4BASE LINENORTH-SOUTHA B C A B C TRANS 2 TRANS 1 ---- 550.00' ----PROPERTY LINE- - - - 377.58' - - - -PROPERTY LI NE---- 377.0' ---- WORK POINT IRON PIPE &---- 592.50' ----PROPERTY LINEPROPERTY LINE ---- 499.10' ---- D GENERAL NOTES FOR GENERAL NOTES PRIOR TO 2015 CONSTRUCTION, SEE REVISION "S" 1. FOR LOCATION OF BENCH MARK SEE CONTOUR & GRADING LAYOUT. 2. FOR SUBSTATION ROUGH GRADE SEE CONTOUR & GRADING LAYOUT. 3. SUBSTATION AREA ENCLOSED BY FENCE AND EXTENDING 5'-0" OUTSIDE. 4. FENCE - 7'-0" HIGH STEEL CHAIN LINK FABRIC AND 1'-0" HIGH VERTICAL HEIGHT BARBED WIRE ON TOP, MOUNTED AT A 45° ANGLE POINTED OUTSIDE OF SUBSTATION. IN ACCORDANCE WITH ENG & DSGN STD ED 4.09.03. 5. SEE STRUCTURAL STEEL DRAWINGS FOR LOAD REQUIREMENTS OF EXTERNAL AND INTERNAL STRAINS. 6. U.G. POWER DUCTS PASS UNDER FENCE MIDWAY BETWEEN FENCE POSTS AND, WHERE POSSIBLE, NOT LESS THAN 2'-6" BELOW GRADE. LEGEND OLD FENCE SIGN WORDED "WARNING, HAZARDOUS VOLTAGES INSIDE, KEEP OUT, CAN SHOCK BURN OR CAUSE DEATH". (THIS SIGN CAN NO LONGER BE ORDERED) A B FENCE WARNING SIGN (ITEM 708), PER ENG & DSGN STD ED 4.10.01. THE SIGNS ARE TO BE MOUNTED 5'-0" FROM GRADE TO TOP OF SIGN, 30-0" - 45'-0" APART AND NO MORE THAN 15'-0" FROM THE CORNERS. ONE SIGN SHOULD BE PLACED ON THE OUTSIDE OF EACH WALK GATE. TWO SIGNS SHOULD BE MOUNTED ON EACH DRIVE GATE, ONE ON THE INSIDE AND ONE ON THE OUTSIDE. (BACK TO BACK ON THE LEFT SIDE OR DRIVERS SIDE PANEL OF THE DOUBLE GATES). BURIED CABLE SIGN (ITEM 706), PER ENG & DSGN STD ED 4.10.06. THE SIGNS ARE TO BE MOUNTED ON EACH SIDE OF FENCE FABRIC, BACK TO BACK AND APPROXIMATELY 3'-6" FROM GRADE TO TOP OF SIGNS. C INDICATES CONCRETE MARKER FOR U.G. CABLE RUNS. (SEE LATEST REVISON APPROXIMATELY 5'-0" FROM THE BOTTOM OF THE DOOR TO THE TOP OF SIGN. INDICATES A YELLOW CONCRETE FILLED BOLLARD (ITEM 299). M-1 F E BURIED CABLE SIGN (ITEM 706), MOUNTED ON POST (BY FIELD), PER ENG & DSGN STD ED 4.10.06. SUBSTATION IDENTIFICATION SIGN (ITEM 718), PER ENG & DSGN STD ED 4.10.02 (TOP) ADDRESS SIGN (ITEM 716) PER ENG & DSGN STD ED 4.10.03 (BOTTOM). THE TOP SIGN MOUNTED 5'-0" FROM GRADE TO TOP OF SIGN AND LOCATED ADJACENT TO WALK OR DRIVE GATES. BATTERY WARNING SIGN (ITEM 707), PER ENG & DSGN STD ED 4.10.04. THE SIGNS ARE TO BE MOUNTED ON THE OUTSIDE OF EACH ELECTRICAL EQUIPMENT ENCLOSURE DOOR, OF PHY DETAIL NL-200902-2-11) FOR DRAWING REFERENCE AND REVISION INFORMATION SEE PHYSICAL INDEX SHEET 1"=100'-0" BB GRADE FINISHED EDGE OF INSTALL 5" PVC FROM CHS B2 FEEDER BAY TO PMH-3 M & PULL IN 180' OF 750MCM CABLE FDR. RISER POLE UNIT #3 13.8KV SWGR CITY OF CHASKA UNIT #4 13.8KV SWGR MVEC/CHASKA TEL ENT BOX 6' 10 "2 177'-5 92'-4"18-750MCM AL. 15KV FDR CABLES FROM SWGR 4 WEST OF FENCE) TO CAB M (9'-12' 2" PVC FROM SWGR 2 GRADE FINISHED EDGE OF B B B TRANS 5 PROPERTY LINE PRO PERTY LIN EPROPERTY LINE~TR 5 TR 2 TR 1 EEE LYM AN BLVDA B C TYPTYP TYPTYPTYP STATIC WIRE (BY TRANS) 795 ACSS (BY TRANS) STATIC WIRE (BY TRANS) STATIC WIRE (BY TRANS) 795 ACSS (BY TRANS) F 24'x60' ENCLOSURE EQUIPMENT ELECTRICAL C C STATIC WIRE (BY TRANS) 795 ACSS (BY TRANS) LINE 0734 (EXC) TO EXCELSIOR 69KV LINE BASE LINE EAST-WEST BASE LINENORTH-SOUTHPROPERTY LINE WORK POINT IRON PIPE & A B C 115KV STRUCTURE N N 46'-0"5 - PMH PEDESTALSDISTRIBUTION FEEDER DUCT E BBBBBBBB B B B B B GATE 20'-0" DRIVE REMOVABLE WALL W/ 15' SPIKE 25' EXT COL W/ 15' SPIKE 25' EXT COL W/ 15' SPIKE 25' EXT COL W/ 15' SPIKE 25' EXT COL W/ 15' SPIKE 25' EXT COL W/ 15' SPIKE 25' EXT COL W/ 15' SPIKE 25' EXT COL W/ 15' SPIKE 25' EXT COL W/ 15' SPIKE 25' EXT COL W/ 15' SPIKE 25' EXT COL W/ 15' SPIKE 25' EXT COL W/ 15' SPIKE 25' EXT COL W/ 25' SPIKE 5' EXT COL W/ 25' SPIKE 5' EXT COL BOTH COL OF SPIKE TYP 56'-8" TO TOP C 115KV LINE 1 TO WESTGATE (WSG 1) LINE 5516 115KV LINE 2 TO WESTGATE (WSG 2) LINE 5569 115KV LINE TO MINNESOTA RIVER (MRR) LINE 5516 115KV LINE TO SCOTT COUNTY (SCO) LINE 5570 SITE PLAN PROPERTY LINE ARE 1'-0" OUTSIDE LINE STRUCTURES 115KV TRANSMISSION MANHOLE 1 MANHOLE 2 UNIT #1 13.8KV SWGR XCEL ENERGY UNIT #2 13.8KV SWGR XCEL ENERGY BLC 61-83 N.O. BLC 71-82 N.O. BLC 72-81 N.O. CITY OF CHASKA'S PMH'S XCEL ENERGY'S METERING CABINETS 129'-0"183'-0"CABLES TO RISER POLE ON THE CORNER OF LYMAN BLVD. ~~ Q P 3 B B B B B B B B B TYP ALL COL W/ 25' SPIKE 5' EXT COL F 3-750 MCM AL 15KV FDR CABLES FROM SWGR UNIT #3 ROUTED ALONG DRIVEWAY DITCH TO RISER POLE ON SW SIDE OF DRIVEWAY ALONG CO ROAD #18. 3-750 MCM AL 15KV FDR CABLES FROM SWGR UNIT #3 ROUTED ALONG DRIVEWAY DITCH TO RISER POLE ON S.E. SIDE OF DRIVEWAY ALONG CO. ROAD #18. (BY CITY OF CHASKA) 100' SHIELD POLE 5'-0"5'-0" 23' 73'-0"44'-0"24'-0"34'-0"30'-0"34'-0"21'-0" 10'48'-0"4'243'-0" (FENCE) 17'-0" 260'-0" (FENCE)312'-0" (FENCE)44'-0"42'-6"5'-0"31'-0"44'-6"41'-6"10'-0"216'-5"90°90°280'-4"5'-0" TYP5'-0"3'-0"280'-4"216'-5"32'-0"35'-0"35'-0"27'-0"24'-0"16'-0"14'-0"BASE LINE EAST-WEST CITY OF CHASKA OWNED OPGW (BY TRANS) C 20'-0" DRIVE GATE REGARDING UNDERGROUND UTILITIES. DRAWINGS SHALL NOT BE RELIED ON AS THE SOLE SOURCE OF INFORMATION 5. SUBSTATION CONSTRUCTION SPECIFICATIONS) FOR ADDITIONAL LOCATE INFORMATION. REFER TO CONSTRUCTION SPECIFICATION (NSP-STD-CIVIL AND PHYSICAL4. FOR KNOWN UNDERGROUND UTILITIES. SEE REFERENCE DRAWINGS (NH-110140-1, NH-110140-2) 3. DAYS PRIOR TO EXCAVATION WORK. LOCATES FROM (PATTI GREEN - SUPERVISOR II FIELD OP'S) AT LEAST TEN (10) BUSINESS FOR UNDERGROUND UTILITY LOCATES INSIDE THE SUBSTATION FENCE, REQUEST 2. BUSINESS DAYS PRIOR TO EXCAVATION WORK. 811 SHALL BE CALLED FOR EVERY EXCAVATION PROJECT AT LEAST THREE (3) LOCATE AND CLEARLY MARK THE LOCATION PRIOR TO ANY EXCAVATION ACTIVITY. DRAWINGS SHALL NOT BE ASSUMED COMPLETE OR ACCURATE. CONSTRUCTION SHALL THE UNDERGROUND UTILITIES SHOWN ON THE PROVIDED ELECTRICAL REFERENCE CAUTION: THERE MAY BE UNDERGROUND UTILITIES/OBSTRUCTIONS IN THIS AREA. 1. PRE-EXCAVATION PROCEDURE SCALE IN FEET 0 150'60'30'120'90' 1" = 30'4'-2"7'-0"1'-0" 6'-0"1'-0"DRAWING SO IT CAN BE UPDATED ON FIELD REVISIONS. IN FIELD WITH TELEPHONE COMPANY AND MARKED ON OF THE PROPERTY. EXACT LOCATION TO BE DETERMINED THE PVC STARTS AT THE EEE AND EXTENDS TO THE EDGE 4" PVC NEEDS TO BE INSTALLED FOR PHONE CABLES. ANTENNA H-FRAME ANTENNA MONOPOLE (125')36'-0"51"=30'-0" 5 4 BLCBLUFF CREEK SUBSTATION GENERAL ARRANGEMENT 2150 LYMAN BLVD A.0001131.008.001.001 IFAB - BLUFF CREEK FIBER FOR LHZ, PEI RECORD 12/14/2018 NH-110110.DGN 11/2/2018 10:10:46 AMNH-11011005/02/2019 D.0001900.049.001.019 BLC - INSTALL FAN TOWER