Loading...
CBA-Chanhassen-Signing Package1 :12 The purchaser agrees to hold the seller harmless against any cause for action for damages which may occur as a result of drilling for piers and foundations, including but not limited to sewer, gas lines or any underground obstacles which the purchaser or others may deem valuable. 8941 Crossroads Blvd Chanhassen MN 55317 Connie Keck JW Vx1100488-R1 07/21/20 07/30/20 This design and engineering is submitted as our proposal, and the right to use or exhibit in any form, is not authorized without written permission by Vixxo. Address City State Account Representative: Notes * * * * * Designer Design # Original Date Revision Date All electrical scope to be completed in a U.L. approved method and shall meet current N.E.C. standards * All electrical components shall be U.L. Listed. * Sign shall be grounded per N.E.C. Article 250. * Insulated conductors as per N.E.C. Code 310.8. type to be used - metallic insulated sealtite. *Disconnect switch as per N.E.C. Code 600.6. s i g n & l i g h t i n g 8941 Crossroads Blvd Chanhassen, MN 55317 D a l l a s O f f i c e 2711 LBJ Freeway Suite 400 Farmers Branch, TX 75234 s i g n & l i g h t i n g 2 :12 The purchaser agrees to hold the seller harmless against any cause for action for damages which may occur as a result of drilling for piers and foundations, including but not limited to sewer, gas lines or any underground obstacles which the purchaser or others may deem valuable. 8941 Crossroads Blvd Chanhassen MN 55317 Connie Keck JW Vx1100488-R1 07/21/20 07/30/20 This design and engineering is submitted as our proposal, and the right to use or exhibit in any form, is not authorized without written permission by Vixxo. Address City State Account Representative: Notes * * * * * Designer Design # Original Date Revision Date All electrical scope to be completed in a U.L. approved method and shall meet current N.E.C. standards * All electrical components shall be U.L. Listed. * Sign shall be grounded per N.E.C. Article 250. * Insulated conductors as per N.E.C. Code 310.8. type to be used - metallic insulated sealtite. *Disconnect switch as per N.E.C. Code 600.6. s i g n & l i g h t i n g SITE PLAN S EW N 74.3 24 74.3 Proposed SQUARE FEET CALCULATIONS SIGN 01: Monument Sign S IG N 3 S I G N 2 S I G N 110’ SETBACK FROM PROPERTY LINE SIGN 02: Exterior Front Channel Letters SIGN 03: Exterior Rear Channel Letters 3 :12 The purchaser agrees to hold the seller harmless against any cause for action for damages which may occur as a result of drilling for piers and foundations, including but not limited to sewer, gas lines or any underground obstacles which the purchaser or others may deem valuable. 8941 Crossroads Blvd Chanhassen MN 55317 Connie Keck JW Vx1100488-R1 07/21/20 07/30/20 This design and engineering is submitted as our proposal, and the right to use or exhibit in any form, is not authorized without written permission by Vixxo. Address City State Account Representative: Notes * * * * * Designer Design # Original Date Revision Date All electrical scope to be completed in a U.L. approved method and shall meet current N.E.C. standards * All electrical components shall be U.L. Listed. * Sign shall be grounded per N.E.C. Article 250. * Insulated conductors as per N.E.C. Code 310.8. type to be used - metallic insulated sealtite. *Disconnect switch as per N.E.C. Code 600.6. s i g n & l i g h t i n g5'-0" O.A.H.D/F MONUMENT SIGN STRUCTURE AND F.C.O. NUMBERS 7'-0" 18"6'-9" 3'-2"3'-5" 1'-7"6" (BRICK BASE TO MATCH BUILDING) 18" 4'-1"3'-7" 4" DIA SUPPORT PIPE UNDISTURBED SOIL 7’-2’(W) x 18”(L) x 5”(D) #4 REBAR @12” O.C. 5” 6” OF CONCRETE OR CRUSHED CINDER BLOCKS PLACED IN BOTTOM OF FOUNDATION PRIOR TO MAIN POUR.2500 PSI CONCRETE (MIN.) TYPICAL OF ONE PIER 5” ELECTRICAL CONDUIT ALONG STEEL PIPE WITH J-BOX S I G N 1 89418941 Section Detail (BLACK SIDES) ½" THICK LETTER FORM ½" (WHITE FACES) NON-CORROSIVE MOUNTING PIN SEALED WITH SILCONE SPECIFICATIONS 1. 18” DEEP ALUMINUM CABINET FILLER PAINTED TO MATCH PMS 349 C GREEN, GLOSSY FINISH. 2. ALL CABINET INTERIORS ARE PAINTED LIGHT ENHANCEMENT WHITE. 3. 1 ½” EXTRUDED ALUMINUM RETAINER SECTIONS PAINTED TO MATCH PMS 349 C GREEN, GLOSSY FINISH. 4. FACES ARE FLAT TRANSLUCENT WHITE ACRYLIC WITH FIRST SURFACE VINYL OVERLAYS & WILL SLIDE OUT FOR SERVICE. 5. VINYL COLORS ARE PER COLOR SCHEDULE. 6. INTERNALLY ILLUMINATED WITH WHITE LED’S. 7. & PAINTED TO MATCH CABINET. CABINET POWER CUTOFF SWITCH TO BE MOUNTED ON SIDE OF CABINET WITH WEATHERPROOF FLIP-UP COVER 8. ADDRESS NUMBERS ARE ½” WHITE ACRYLIC MOUNTED TO BASE WITH STUD MOUNTS. (BOTH SIDES) F.C.O. NUMBERS SPECIFICATIONS 1. ½” THICK OPAQUE WHITE GEMINI #5687 PLASTIC LETTER FORMS. NUMBERS HAVE WHITE FACES WITH BLACK EDGE (SIDES) 2. LETTERS ARE NON-ILLUMINATED. 3. COPY STYLE: CLARENDON FORTUNE BOLD 4. FLUSH MOUNTED TO MONUMENT WITH APPROPRIATE NON-CORROSIVE MOUNTING HARDWARE AND SEALED WITH SILICONE. PMS 349 C ARLON 3M #3630-26 LOGO VINYL DETAIL WHITE #3630-26 GREEN VINYL #72 LIGHT GRAY VINYL SCALE: 3/8”=1’-0” SQUARE FOOTAGE: SQ. FT. PER FACE: 24 CABINET POWER CUTOFF SWITCH TO BE MOUNTED ON SIDE OF CABINET WITH WEATHERPROOF FLIP-UP COVER & PAINTED TO MATCH CABINET. 4 :12 The purchaser agrees to hold the seller harmless against any cause for action for damages which may occur as a result of drilling for piers and foundations, including but not limited to sewer, gas lines or any underground obstacles which the purchaser or others may deem valuable. 8941 Crossroads Blvd Chanhassen MN 55317 Connie Keck JW Vx1100488-R1 07/21/20 07/30/20 This design and engineering is submitted as our proposal, and the right to use or exhibit in any form, is not authorized without written permission by Vixxo. Address City State Account Representative: Notes * * * * * Designer Design # Original Date Revision Date All electrical scope to be completed in a U.L. approved method and shall meet current N.E.C. standards * All electrical components shall be U.L. Listed. * Sign shall be grounded per N.E.C. Article 250. * Insulated conductors as per N.E.C. Code 310.8. type to be used - metallic insulated sealtite. *Disconnect switch as per N.E.C. Code 600.6. s i g n & l i g h t i n g S I G N 2 156’-0” S C AL E: N.T.S. 37’-2” 24” S CO P E O F WO R K: 1. FABRI C AT E, S H I P & IN STAL L (1) ON E N E W S E T - 22” INDI VI D UA L C H A N N E L L E T T E RS WITH BACK PA NE LS O N W IR E-WAYS. B U I L D I N G (F R O N T) E L E VAT I O N S CAL E: 3/32”=1’-0” (L H 9) I L LUM IN AT E D 22” C H A N N E L L E T T E RS W I T H B AC K PA N E LS O N W I R E-WAY S 5 :12 The purchaser agrees to hold the seller harmless against any cause for action for damages which may occur as a result of drilling for piers and foundations, including but not limited to sewer, gas lines or any underground obstacles which the purchaser or others may deem valuable. 8941 Crossroads Blvd Chanhassen MN 55317 Connie Keck JW Vx1100488-R1 07/21/20 07/30/20 This design and engineering is submitted as our proposal, and the right to use or exhibit in any form, is not authorized without written permission by Vixxo. Address City State Account Representative: Notes * * * * * Designer Design # Original Date Revision Date All electrical scope to be completed in a U.L. approved method and shall meet current N.E.C. standards * All electrical components shall be U.L. Listed. * Sign shall be grounded per N.E.C. Article 250. * Insulated conductors as per N.E.C. Code 310.8. type to be used - metallic insulated sealtite. *Disconnect switch as per N.E.C. Code 600.6. s i g n & l i g h t i n g S I G N 2 5” FABRICATED ALUM INUM LETTER RE TURN S PAINTED BLACK PAINT INTE RIOR WITH LIGHT ENHANCING PAINT 1” TRIM CAP BLACK NO N-CORROSIVE INSTALL ATION HARDWARE: SEE DE TAIL 3/16” THICK #7328 PLEX/POLYCARBONATE FACE WHITE LED DIODE M O DULE WHITE (MIN. 15’ LEADS) ¼” WEEP HOLES (2) TWO PER LET TER LOW VOLTAGE ELECTRONIC TRANSFORMER LOCATED IN INT ERIOR WALL AREA INSIDE A PROTEC TIVE CASE B OX GROUNDED WALL PASS-THRU SEALED WATE R TI GHT (SHOWN AS TYPICAL / FRONT E LEVATION TO HAVE PASS THROUGH AT TOP OF LETTER) WATE RPROOF FLEXIBLE CONDUIT FOR WIRING F LAT ALUMINUM BACK WELDED TO RE TURN S PAINTED BLACK 9 8 7 6 5 4 3 2 1 10 1 2 3 4 6 5 8 7 9 10 11 UL LISTED AND APPROVED 20AMP DISCONNECT SWITCH S P E C I F I C AT I O N S S I D E S EC T I O N V I E W M O U N T I N G D ETAI L 11 12 12 2” DEEP WIRE-WAY PAINTED BLACK 13 13 1” CONTOUR .063 ALUMI NU M PAINTED GLOSS BLACK C OLOR SC H E D U L E PMS BLACK PMS 349 C ARLON 3M #3630-26 BLACK S C A L E 3/16”=1’22” L E D I L LU M I N AT E D C H A N N E L L E T T E R S E T W I T H BAC K PA N E L S O N W I R E-WAYS 37’-2” 1’-10”2’-0” 9”9” 74.3 SQF T 6 :12 The purchaser agrees to hold the seller harmless against any cause for action for damages which may occur as a result of drilling for piers and foundations, including but not limited to sewer, gas lines or any underground obstacles which the purchaser or others may deem valuable. 8941 Crossroads Blvd Chanhassen MN 55317 Connie Keck JW Vx1100488-R1 07/21/20 07/30/20 This design and engineering is submitted as our proposal, and the right to use or exhibit in any form, is not authorized without written permission by Vixxo. Address City State Account Representative: Notes * * * * * Designer Design # Original Date Revision Date All electrical scope to be completed in a U.L. approved method and shall meet current N.E.C. standards * All electrical components shall be U.L. Listed. * Sign shall be grounded per N.E.C. Article 250. * Insulated conductors as per N.E.C. Code 310.8. type to be used - metallic insulated sealtite. *Disconnect switch as per N.E.C. Code 600.6. s i g n & l i g h t i n g S I G N 3 S C AL E: N.T.S. (L H 9) I L LUM IN AT E D 22” C H A N N E L L E T T E RS W I T H B AC K PA N E LS O N R A C E-WAYS B U I L D I N G (R E A R ) E L E VAT I O N S CAL E: 3/32”=1’-0” S CO P E O F WO R K: 1. FABRI C AT E, S H I P & IN STAL L (1) ON E N E W S E T - 22” INDI VI D UA L C H A N N E L L E T T E RS WITH BACK PA NE LS O N RAC E-WAYS. 156’-0” 37’-2” 24” 7 :12 The purchaser agrees to hold the seller harmless against any cause for action for damages which may occur as a result of drilling for piers and foundations, including but not limited to sewer, gas lines or any underground obstacles which the purchaser or others may deem valuable. 8941 Crossroads Blvd Chanhassen MN 55317 Connie Keck JW Vx1100488-R1 07/21/20 07/30/20 This design and engineering is submitted as our proposal, and the right to use or exhibit in any form, is not authorized without written permission by Vixxo. Address City State Account Representative: Notes * * * * * Designer Design # Original Date Revision Date All electrical scope to be completed in a U.L. approved method and shall meet current N.E.C. standards * All electrical components shall be U.L. Listed. * Sign shall be grounded per N.E.C. Article 250. * Insulated conductors as per N.E.C. Code 310.8. type to be used - metallic insulated sealtite. *Disconnect switch as per N.E.C. Code 600.6. s i g n & l i g h t i n g S I G N 3 22” L E D I L LU MI N AT E D C H A N N E L L E T T E R S E T W I T H BA C K PA N E LS O N R AC E-WAYS 9 8 7 6 5 4 3 2 1 10 5” FABR ICATED ALUMINUM LET TER RETURNS PAINTED BLAC K PAINT INTERIOR WITH LIGHT ENH ANCING PAINT 1” TRIM CAP RETAINE R BLACK 3/16” THICK PLEX/POLYCARBONATE FACE WHITE ¼” WEEP HOLES (2) TWO PER LE TTER GROUNDED WALL PASS-THRU SEALED WAT ER TIGHT NON-CORROSIVE INSTALLATION H ARDWARE: SEE DETAIL LED DIOD E MODULE WHITE ¼” THICK ME TAL FLAT BAR FOR A SECURE INSTALLATIO N LOW VO LTAGE ELEC TRONIC T RANSFORME R MOUNTED IN A 7 ¼” X 7 ¼” EXTRUDED .050 ALUM. RACEWAY SUPPORT/WIRING BOX PAINTED BLAC K VISIBLE CUT-OFF SWITCH WITH FLIP-UP COVER FLAT ALUMINUM BAC K WELDED TO RETURNS 11 1 2 3 4 5 8 11 9 10 7 6 1” CONTOUR .063 ALUMINUM PAINTED GLOSS BLACK 12 12 S P E C I F I C AT I O N S S I D E S EC T I O N V I E W M O U N T I N G D ETAI L C OLOR SC H E D U L E PMS BLACK PMS 349 C ARLON 3M #3630-26 BLACK S C A L E 3/16”=1’ 37’-2” 1’-10”2’-0” 9”9” 74.3 SQF T 8 :12 The purchaser agrees to hold the seller harmless against any cause for action for damages which may occur as a result of drilling for piers and foundations, including but not limited to sewer, gas lines or any underground obstacles which the purchaser or others may deem valuable. 8941 Crossroads Blvd Chanhassen MN 55317 Connie Keck JW Vx1100488-R1 07/21/20 07/30/20 This design and engineering is submitted as our proposal, and the right to use or exhibit in any form, is not authorized without written permission by Vixxo. Address City State Account Representative: Notes * * * * * Designer Design # Original Date Revision Date All electrical scope to be completed in a U.L. approved method and shall meet current N.E.C. standards * All electrical components shall be U.L. Listed. * Sign shall be grounded per N.E.C. Article 250. * Insulated conductors as per N.E.C. Code 310.8. type to be used - metallic insulated sealtite. *Disconnect switch as per N.E.C. Code 600.6. s i g n & l i g h t i n g S IG N 4 A D D R E S S N U M B E R F.C.O. L E T T E R E L E VAT I O N (1) O N E S E T R EQ U I R E D SCOP E OF WOR K 1. FAB R IC ATE, SH IP & INSTALL (1) O NE SE T NE W G E MI NI A D DRE S S NUM B ERS. SP ECIF IC ATIONS 1. ½” TH IC K OPAQ U E WHITE GEM IN I #5687 PL ASTI C LET TER FO R MS. N U MBERS H AV E WHI TE FAC ES W IT H BL ACK E DG E (SI DE S) 2. LET TERS A RE NON-I LLUM IN ATED. 3. COP Y STYL E: C LA REN DON F O RTUN E B O LD 4. F LUS H MOUN T E D TO BUI LD IN G WITH APP ROP RIAT E NON-C O RRO SI V E M O U NT ING H ARDWARE A ND S EAL E D WI TH SI LI CON E. SC A L E: 1”=1’-0” S Q UA R E FOOTA G E: 2.56 SCALE: 1/8”=1’-0” 89418941 10” 3’-1” Section Detail (BLACK SIDES) ½" THICK LETTER FORM ½" (WHITE FACES) NON-CORROSIVE MOUNTING PIN SEALED WITH SILCONE 894110” 3’-1” (L H 9) E N D E L E VAT I O N N U M B E R FO R M S 9 :12 The purchaser agrees to hold the seller harmless against any cause for action for damages which may occur as a result of drilling for piers and foundations, including but not limited to sewer, gas lines or any underground obstacles which the purchaser or others may deem valuable. 8941 Crossroads Blvd Chanhassen MN 55317 Connie Keck JW Vx1100488-R1 07/21/20 07/30/20 This design and engineering is submitted as our proposal, and the right to use or exhibit in any form, is not authorized without written permission by Vixxo. Address City State Account Representative: Notes * * * * * Designer Design # Original Date Revision Date All electrical scope to be completed in a U.L. approved method and shall meet current N.E.C. standards * All electrical components shall be U.L. Listed. * Sign shall be grounded per N.E.C. Article 250. * Insulated conductors as per N.E.C. Code 310.8. type to be used - metallic insulated sealtite. *Disconnect switch as per N.E.C. Code 600.6. s i g n & l i g h t i n g SC A L E: 3/16”=1’-0” S I G N 6 SI G N 5(2) 12” x 73 ½” ETCHED VINYL STRIPS (1) 15” x 32” ETCHED VINYL LOGO (2) 12” x 62” ETCHED VINYL STRIPS (1) 15” x 32” ETCHED VINYL LOGO (1) 12” x 24” ETCHED VINYL STRIP CHRISTIAN BROTHERS SINCE 1982 FCO LETTERS T-2 RECEPTION / SERVICE FLOOR PLAN 10 :12 The purchaser agrees to hold the seller harmless against any cause for action for damages which may occur as a result of drilling for piers and foundations, including but not limited to sewer, gas lines or any underground obstacles which the purchaser or others may deem valuable. 8941 Crossroads Blvd Chanhassen MN 55317 Connie Keck JW Vx1100488-R1 07/21/20 07/30/20 This design and engineering is submitted as our proposal, and the right to use or exhibit in any form, is not authorized without written permission by Vixxo. Address City State Account Representative: Notes * * * * * Designer Design # Original Date Revision Date All electrical scope to be completed in a U.L. approved method and shall meet current N.E.C. standards * All electrical components shall be U.L. Listed. * Sign shall be grounded per N.E.C. Article 250. * Insulated conductors as per N.E.C. Code 310.8. type to be used - metallic insulated sealtite. *Disconnect switch as per N.E.C. Code 600.6. s i g n & l i g h t i n g S CAL E: 1/4”=1’-0” COLOR SCHEDULE #07 ETCHED GLASS VINYL GLASS ETCHED VINYL GRAPHIC RECEPTION / WAITING SERVICE GLASS ETCHED VINYL SPECIFICATIONS 1. #07 ETCHED GLASS VINYL OVERLAY. 2. OVERLAY APPLIED TO GLASS 2ND SURFACE (BACK OF GLASS) 1Since9821Since982 CENTER ON GLASS CENTER ON GLASS CENTER ON GLASS SI GN 5 12” 12” 62”73 ½” (2) 12” x 73 ½” ETCHED VINYL STRIPS (1) 15” x 32” ETCHED VINYL LOGO (1) 12” x 24” ETCHED VINYL STRIP (2) 12” x 62” ETCHED VINYL STRIPS (1) 15” x 32” ETCHED VINYL LOGO 32”32” 24” 12” 15” 11 :12 The purchaser agrees to hold the seller harmless against any cause for action for damages which may occur as a result of drilling for piers and foundations, including but not limited to sewer, gas lines or any underground obstacles which the purchaser or others may deem valuable. 8941 Crossroads Blvd Chanhassen MN 55317 Connie Keck JW Vx1100488-R1 07/21/20 07/30/20 This design and engineering is submitted as our proposal, and the right to use or exhibit in any form, is not authorized without written permission by Vixxo. Address City State Account Representative: Notes * * * * * Designer Design # Original Date Revision Date All electrical scope to be completed in a U.L. approved method and shall meet current N.E.C. standards * All electrical components shall be U.L. Listed. * Sign shall be grounded per N.E.C. Article 250. * Insulated conductors as per N.E.C. Code 310.8. type to be used - metallic insulated sealtite. *Disconnect switch as per N.E.C. Code 600.6. s i g n & l i g h t i n g I N T E R I O R L E T T E R FO R M S 9’-0” 1 ¼”5” 5 ½” SC A L E: ¾”=1’-0”I N T E R I O R F L AT C U T O U T L E T T E R S E T E L E VAT I O N (1) O N E S E T R EQ U I R E D SCOPE O F WO RK 1. FA BRI CATE, SH IP & INSTA L L (1) O NE SE T FLAT CUT OUT LET T E RS. SPECIFI CATI ON S 1. LETTERS: ¼” THICK SINTRA PAINTED FIRST SURFACE WHITE GLOSSY FINISH. 2. COP Y STY L E: CLA RE N D ON 3. LET TE RS MO U N TED FLUSH TO WALL WITH VHB TA PE AN D SI L ICONE. SERVICE S C A L E: 1/4”=1’-0” SI GN 6 1Since9821Since982 9"9" CENTER ON WALL CENTER ON WALL EX A M P L E ¼” THICK SINTRA FORM SECT ION D E TAI L VHB TAPE WITH SILICONE ADHESIVE AS REQUIRED CO LO R S C H ED U L E W HITE 5 ½" 1Since982 12 :12 The purchaser agrees to hold the seller harmless against any cause for action for damages which may occur as a result of drilling for piers and foundations, including but not limited to sewer, gas lines or any underground obstacles which the purchaser or others may deem valuable. 8941 Crossroads Blvd Chanhassen MN 55317 Connie Keck JW Vx1100488-R1 07/21/20 07/30/20 This design and engineering is submitted as our proposal, and the right to use or exhibit in any form, is not authorized without written permission by Vixxo. Address City State Account Representative: Notes * * * * * Designer Design # Original Date Revision Date All electrical scope to be completed in a U.L. approved method and shall meet current N.E.C. standards * All electrical components shall be U.L. Listed. * Sign shall be grounded per N.E.C. Article 250. * Insulated conductors as per N.E.C. Code 310.8. type to be used - metallic insulated sealtite. *Disconnect switch as per N.E.C. Code 600.6. s i g n & l i g h t i n g WINDOW VINYL S I G N 7 SCALE: 1 ½”=1’-0” COLOR SCHEDULE #07 ETCHED GLASS VINYL WINDOW VINYL GRAPHIC ELEVATION SATURDAYS 8AM - 2PM 20” 24” 12 ½” 24 ½” 36” 5 ¾” 1 ½” 1 ½” 1 ½” 1 ¼” 1” 1 ½” 1 ½” SCALE: ¾”=1’-0” Nice difference.SATURDAYS 8AM - 2PM Nice difference. (1) ONE REQUIRED SPECIFICATIONS 1. #07 ETCHED GLASS VINYL OVERLAY. 2. OVERLAY APPLIED TO GLASS 2ND SURFACE (INSIDE OFFICE)