Chanhassen_Signing Package1 :12
The purchaser agrees to hold the seller harmless against
any cause for action for damages which may occur as a
result of drilling for piers and foundations, including but not
limited to sewer, gas lines or any underground obstacles
which the purchaser or others may deem valuable.
8941 Crossroads Blvd
Chanhassen
MN 55317
Connie Keck
JW
Vx1100488-R2
07/21/20
10/16/20
This design and engineering is
submitted as our proposal, and
the right to use or exhibit in any
form, is not authorized without
written permission by Vixxo.
Address
City
State
Account Representative:
Notes
*
*
*
*
*
Designer
Design #
Original Date
Revision Date
All electrical scope to be completed in a U.L. approved
method and shall meet current N.E.C. standards
* All electrical components shall be U.L. Listed.
* Sign shall be grounded per N.E.C. Article 250.
* Insulated conductors as per N.E.C. Code 310.8.
type to be used - metallic insulated sealtite.
*Disconnect switch as per N.E.C. Code 600.6.
s i g n & l i g h t i n g
8941 Crossroads Blvd
Chanhassen, MN 55317
D a l l a s O f f i c e 2711 LBJ Freeway Suite 400 Farmers Branch, TX 75234 s i g n & l i g h t i n g
2 :12
The purchaser agrees to hold the seller harmless against
any cause for action for damages which may occur as a
result of drilling for piers and foundations, including but not
limited to sewer, gas lines or any underground obstacles
which the purchaser or others may deem valuable.
8941 Crossroads Blvd
Chanhassen
MN 55317
Connie Keck
JW
Vx1100488-R2
07/21/20
10/16/20
This design and engineering is
submitted as our proposal, and
the right to use or exhibit in any
form, is not authorized without
written permission by Vixxo.
Address
City
State
Account Representative:
Notes
*
*
*
*
*
Designer
Design #
Original Date
Revision Date
All electrical scope to be completed in a U.L. approved
method and shall meet current N.E.C. standards
* All electrical components shall be U.L. Listed.
* Sign shall be grounded per N.E.C. Article 250.
* Insulated conductors as per N.E.C. Code 310.8.
type to be used - metallic insulated sealtite.
*Disconnect switch as per N.E.C. Code 600.6.
s i g n & l i g h t i n g
SITE PLAN
S
EW
N
74.3
24
42
Proposed
SQUARE FEET CALCULATIONS
SIGN 01: Monument Sign
S IG N
3
S I G N
2
S I G N
110’ SETBACK FROM
PROPERTY LINE SIGN 02: Exterior Front Channel Letters
SIGN 03: Exterior Rear Channel Letters
3 :12
The purchaser agrees to hold the seller harmless against
any cause for action for damages which may occur as a
result of drilling for piers and foundations, including but not
limited to sewer, gas lines or any underground obstacles
which the purchaser or others may deem valuable.
8941 Crossroads Blvd
Chanhassen
MN 55317
Connie Keck
JW
Vx1100488-R2
07/21/20
10/16/20
This design and engineering is
submitted as our proposal, and
the right to use or exhibit in any
form, is not authorized without
written permission by Vixxo.
Address
City
State
Account Representative:
Notes
*
*
*
*
*
Designer
Design #
Original Date
Revision Date
All electrical scope to be completed in a U.L. approved
method and shall meet current N.E.C. standards
* All electrical components shall be U.L. Listed.
* Sign shall be grounded per N.E.C. Article 250.
* Insulated conductors as per N.E.C. Code 310.8.
type to be used - metallic insulated sealtite.
*Disconnect switch as per N.E.C. Code 600.6.
s i g n & l i g h t i n g5'-0" O.A.H.D/F MONUMENT SIGN STRUCTURE AND F.C.O. NUMBERS
7'-0"
18"6'-9"
3'-2"3'-5"
1'-7"6"
(BRICK BASE TO MATCH BUILDING)
18"
4'-1"3'-7"
4" DIA SUPPORT PIPE
UNDISTURBED SOIL
7’-2’(W) x 18”(L) x 5”(D)
#4 REBAR @12” O.C.
5”
6” OF CONCRETE OR CRUSHED
CINDER BLOCKS PLACED IN BOTTOM
OF FOUNDATION PRIOR TO MAIN POUR.2500 PSI CONCRETE (MIN.)
TYPICAL OF ONE PIER
5” ELECTRICAL CONDUIT
ALONG STEEL PIPE
WITH J-BOX
S I G N
1
89418941
Section Detail
(BLACK SIDES)
½" THICK LETTER FORM
½"
(WHITE FACES)
NON-CORROSIVE MOUNTING PIN
SEALED WITH SILCONE
SPECIFICATIONS
1. 18” DEEP ALUMINUM CABINET FILLER PAINTED TO MATCH PMS 349 C GREEN, GLOSSY FINISH.
2. ALL CABINET INTERIORS ARE PAINTED LIGHT ENHANCEMENT WHITE.
3. 1 ½” EXTRUDED ALUMINUM RETAINER SECTIONS PAINTED TO MATCH PMS 349 C GREEN, GLOSSY FINISH.
4. FACES ARE FLAT TRANSLUCENT WHITE ACRYLIC WITH FIRST SURFACE VINYL OVERLAYS & WILL SLIDE OUT FOR SERVICE.
5. VINYL COLORS ARE PER COLOR SCHEDULE.
6. INTERNALLY ILLUMINATED WITH WHITE LED’S.
7.
& PAINTED TO MATCH CABINET.
CABINET POWER CUTOFF SWITCH TO BE MOUNTED ON SIDE OF CABINET WITH WEATHERPROOF FLIP-UP COVER
8. ADDRESS NUMBERS ARE ½” WHITE ACRYLIC
MOUNTED TO BASE WITH STUD MOUNTS. (BOTH SIDES)
F.C.O. NUMBERS SPECIFICATIONS
1. ½” THICK OPAQUE WHITE GEMINI #5687 PLASTIC
LETTER FORMS.
NUMBERS HAVE WHITE FACES WITH BLACK EDGE (SIDES)
2. LETTERS ARE NON-ILLUMINATED.
3. COPY STYLE: CLARENDON FORTUNE BOLD
4. FLUSH MOUNTED TO MONUMENT WITH APPROPRIATE
NON-CORROSIVE MOUNTING HARDWARE AND SEALED
WITH SILICONE.
PMS 349 C
ARLON 3M #3630-26
LOGO VINYL DETAIL
WHITE #3630-26 GREEN VINYL
#72 LIGHT GRAY VINYL
SCALE: 3/8”=1’-0”
SQUARE FOOTAGE:
SQ. FT. PER FACE: 24
CABINET POWER CUTOFF SWITCH
TO BE MOUNTED ON SIDE OF CABINET
WITH WEATHERPROOF FLIP-UP COVER
& PAINTED TO MATCH CABINET.
4 :12
The purchaser agrees to hold the seller harmless against
any cause for action for damages which may occur as a
result of drilling for piers and foundations, including but not
limited to sewer, gas lines or any underground obstacles
which the purchaser or others may deem valuable.
8941 Crossroads Blvd
Chanhassen
MN 55317
Connie Keck
JW
Vx1100488-R2
07/21/20
10/16/20
This design and engineering is
submitted as our proposal, and
the right to use or exhibit in any
form, is not authorized without
written permission by Vixxo.
Address
City
State
Account Representative:
Notes
*
*
*
*
*
Designer
Design #
Original Date
Revision Date
All electrical scope to be completed in a U.L. approved
method and shall meet current N.E.C. standards
* All electrical components shall be U.L. Listed.
* Sign shall be grounded per N.E.C. Article 250.
* Insulated conductors as per N.E.C. Code 310.8.
type to be used - metallic insulated sealtite.
*Disconnect switch as per N.E.C. Code 600.6.
s i g n & l i g h t i n g
S I G N
2
157’-6”
S C AL E: N.T.S.
37’-2”
24”
S CO P E O F WO R K:
1. FABRI C AT E, S H I P & IN STAL L (1) ON E N E W S E T - 22” INDI VI D UA L C H A N N E L L E T T E RS WITH BACK PA NE LS O N W IR E-WAYS.
B U I L D I N G (F R O N T) E L E VAT I O N S CAL E: 3/32”=1’-0”
(L H 9) I L LUM IN AT E D 22” C H A N N E L L E T T E RS W I T H B AC K PA N E LS O N W I R E-WAY S
5 :12
The purchaser agrees to hold the seller harmless against
any cause for action for damages which may occur as a
result of drilling for piers and foundations, including but not
limited to sewer, gas lines or any underground obstacles
which the purchaser or others may deem valuable.
8941 Crossroads Blvd
Chanhassen
MN 55317
Connie Keck
JW
Vx1100488-R2
07/21/20
10/16/20
This design and engineering is
submitted as our proposal, and
the right to use or exhibit in any
form, is not authorized without
written permission by Vixxo.
Address
City
State
Account Representative:
Notes
*
*
*
*
*
Designer
Design #
Original Date
Revision Date
All electrical scope to be completed in a U.L. approved
method and shall meet current N.E.C. standards
* All electrical components shall be U.L. Listed.
* Sign shall be grounded per N.E.C. Article 250.
* Insulated conductors as per N.E.C. Code 310.8.
type to be used - metallic insulated sealtite.
*Disconnect switch as per N.E.C. Code 600.6.
s i g n & l i g h t i n g
S I G N
2
5” FABRICATED ALUM INUM LETTER RE TURN S
PAINTED BLACK
PAINT INTE RIOR WITH LIGHT ENHANCING PAINT
1” TRIM CAP
BLACK
NO N-CORROSIVE INSTALL ATION HARDWARE:
SEE DE TAIL
3/16” THICK #7328 PLEX/POLYCARBONATE FACE
WHITE
LED DIODE M O DULE WHITE (MIN. 15’ LEADS)
¼” WEEP HOLES (2) TWO PER LET TER
LOW VOLTAGE ELECTRONIC TRANSFORMER
LOCATED IN INT ERIOR WALL AREA INSIDE A
PROTEC TIVE CASE B OX
GROUNDED WALL PASS-THRU SEALED WATE R TI GHT
(SHOWN AS TYPICAL / FRONT E LEVATION TO
HAVE PASS THROUGH AT TOP OF LETTER)
WATE RPROOF FLEXIBLE CONDUIT FOR WIRING
F LAT ALUMINUM BACK WELDED TO RE TURN S
PAINTED BLACK
9
8
7
6
5
4
3
2
1
10
1
2
3
4
6
5
8
7
9
10
11 UL LISTED AND APPROVED 20AMP
DISCONNECT SWITCH
S P E C I F I C AT I O N S S I D E S EC T I O N V I E W M O U N T I N G D ETAI L
11
12
12 2” DEEP WIRE-WAY PAINTED BLACK
13
13 1” CONTOUR .063 ALUMI NU M PAINTED GLOSS BLACK
C OLOR SC H E D U L E
PMS BLACK
PMS 349 C
ARLON 3M #3630-26
BLACK
S C A L E 3/16”=1’22” L E D I L LU M I N AT E D C H A N N E L L E T T E R S E T W I T H BAC K PA N E L S O N W I R E-WAYS
37’-2”
1’-10”2’-0”
9”9”
74.3 SQF T
6 :12
The purchaser agrees to hold the seller harmless against
any cause for action for damages which may occur as a
result of drilling for piers and foundations, including but not
limited to sewer, gas lines or any underground obstacles
which the purchaser or others may deem valuable.
8941 Crossroads Blvd
Chanhassen
MN 55317
Connie Keck
JW
Vx1100488-R2
07/21/20
10/16/20
This design and engineering is
submitted as our proposal, and
the right to use or exhibit in any
form, is not authorized without
written permission by Vixxo.
Address
City
State
Account Representative:
Notes
*
*
*
*
*
Designer
Design #
Original Date
Revision Date
All electrical scope to be completed in a U.L. approved
method and shall meet current N.E.C. standards
* All electrical components shall be U.L. Listed.
* Sign shall be grounded per N.E.C. Article 250.
* Insulated conductors as per N.E.C. Code 310.8.
type to be used - metallic insulated sealtite.
*Disconnect switch as per N.E.C. Code 600.6.
s i g n & l i g h t i n g
S I G N
3
S C AL E: N.T.S.
(L H 9) I L LUM IN AT E D 16” C H A N N E L L E T T E RS W I T H B AC K PA N E LS O N R A C E-WAYS
B U I L D I N G (R E A R ) E L E VAT I O N S CAL E: 3/32”=1’-0”
S CO P E O F WO R K:
1. FABRI C AT E, S H I P & IN STAL L (1) ON E N E W S E T - 16” INDI VI D UA L C H A N N E L L E T T E RS WITH BACK PA NE LS O N RAC E-WAYS.
28’
18”
157’-6”
7 :12
The purchaser agrees to hold the seller harmless against
any cause for action for damages which may occur as a
result of drilling for piers and foundations, including but not
limited to sewer, gas lines or any underground obstacles
which the purchaser or others may deem valuable.
8941 Crossroads Blvd
Chanhassen
MN 55317
Connie Keck
JW
Vx1100488-R2
07/21/20
10/16/20
This design and engineering is
submitted as our proposal, and
the right to use or exhibit in any
form, is not authorized without
written permission by Vixxo.
Address
City
State
Account Representative:
Notes
*
*
*
*
*
Designer
Design #
Original Date
Revision Date
All electrical scope to be completed in a U.L. approved
method and shall meet current N.E.C. standards
* All electrical components shall be U.L. Listed.
* Sign shall be grounded per N.E.C. Article 250.
* Insulated conductors as per N.E.C. Code 310.8.
type to be used - metallic insulated sealtite.
*Disconnect switch as per N.E.C. Code 600.6.
s i g n & l i g h t i n g
S I G N
3
16” L E D I L LU MI N AT E D C H A N N E L L E T T E R S E T W I T H BA C K PA N E LS O N R AC E-WAYS
9
8
7
6
5
4
3
2
1
10
5” FABR ICATED ALUMINUM LET TER RETURNS
PAINTED BLAC K
PAINT INTERIOR WITH LIGHT ENH ANCING PAINT
1” TRIM CAP RETAINE R
BLACK
3/16” THICK PLEX/POLYCARBONATE FACE
WHITE
¼” WEEP HOLES (2) TWO PER LE TTER
GROUNDED WALL PASS-THRU
SEALED WAT ER TIGHT
NON-CORROSIVE INSTALLATION H ARDWARE:
SEE DETAIL
LED DIOD E MODULE WHITE
¼” THICK ME TAL FLAT BAR FOR
A SECURE INSTALLATIO N
LOW VO LTAGE ELEC TRONIC T RANSFORME R
MOUNTED IN A 7 ¼” X 7 ¼” EXTRUDED .050
ALUM. RACEWAY SUPPORT/WIRING BOX
PAINTED BLAC K
VISIBLE CUT-OFF SWITCH WITH FLIP-UP COVER
FLAT ALUMINUM BAC K WELDED TO RETURNS
11
1
2
3
4
5
8
11
9
10
7
6
1” CONTOUR .063 ALUMINUM PAINTED GLOSS BLACK 12
12
S P E C I F I C AT I O N S S I D E S EC T I O N V I E W M O U N T I N G D ETAI L C OLOR SC H E D U L E
PMS BLACK
PMS 349 C
ARLON 3M #3630-26
BLACK
S C A L E 1/4”=1’
28’-0”
16”18”
6 ¾”6 ¾”
42 SQ FT
8 :12
The purchaser agrees to hold the seller harmless against
any cause for action for damages which may occur as a
result of drilling for piers and foundations, including but not
limited to sewer, gas lines or any underground obstacles
which the purchaser or others may deem valuable.
8941 Crossroads Blvd
Chanhassen
MN 55317
Connie Keck
JW
Vx1100488-R2
07/21/20
10/16/20
This design and engineering is
submitted as our proposal, and
the right to use or exhibit in any
form, is not authorized without
written permission by Vixxo.
Address
City
State
Account Representative:
Notes
*
*
*
*
*
Designer
Design #
Original Date
Revision Date
All electrical scope to be completed in a U.L. approved
method and shall meet current N.E.C. standards
* All electrical components shall be U.L. Listed.
* Sign shall be grounded per N.E.C. Article 250.
* Insulated conductors as per N.E.C. Code 310.8.
type to be used - metallic insulated sealtite.
*Disconnect switch as per N.E.C. Code 600.6.
s i g n & l i g h t i n g
S IG N
4
A D D R E S S N U M B E R F.C.O. L E T T E R E L E VAT I O N
(1) O N E S E T R EQ U I R E D
SCOP E OF WOR K
1. FAB R IC ATE, SH IP & INSTALL (1) O NE SE T NE W G E MI NI A D DRE S S NUM B ERS.
SP ECIF IC ATIONS
1. ½” TH IC K OPAQ U E WHITE GEM IN I #5687 PL ASTI C LET TER FO R MS.
N U MBERS H AV E WHI TE FAC ES W IT H BL ACK E DG E (SI DE S)
2. LET TERS A RE NON-I LLUM IN ATED.
3. COP Y STYL E: C LA REN DON F O RTUN E B O LD
4. F LUS H MOUN T E D TO BUI LD IN G WITH APP ROP RIAT E NON-C O RRO SI V E
M O U NT ING H ARDWARE A ND S EAL E D WI TH SI LI CON E.
SC A L E: 1”=1’-0”
S Q UA R E FOOTA G E: 2.56
SCALE: 1/8”=1’-0”
89418941
3’-1”
Section Detail
(BLACK SIDES)
½" THICK LETTER FORM
½"
(WHITE FACES)
NON-CORROSIVE MOUNTING PIN
SEALED WITH SILCONE
894110”
3’-1”
(L H 9) E N D E L E VAT I O N N U M B E R FO R M S
10”
9 :12
The purchaser agrees to hold the seller harmless against
any cause for action for damages which may occur as a
result of drilling for piers and foundations, including but not
limited to sewer, gas lines or any underground obstacles
which the purchaser or others may deem valuable.
8941 Crossroads Blvd
Chanhassen
MN 55317
Connie Keck
JW
Vx1100488-R2
07/21/20
10/16/20
This design and engineering is
submitted as our proposal, and
the right to use or exhibit in any
form, is not authorized without
written permission by Vixxo.
Address
City
State
Account Representative:
Notes
*
*
*
*
*
Designer
Design #
Original Date
Revision Date
All electrical scope to be completed in a U.L. approved
method and shall meet current N.E.C. standards
* All electrical components shall be U.L. Listed.
* Sign shall be grounded per N.E.C. Article 250.
* Insulated conductors as per N.E.C. Code 310.8.
type to be used - metallic insulated sealtite.
*Disconnect switch as per N.E.C. Code 600.6.
s i g n & l i g h t i n g
SC A L E: 3/16”=1’-0”
S I G N
6
SI G N
5(2) 12” x 73 ½”
ETCHED VINYL STRIPS
(1) 15” x 32”
ETCHED VINYL LOGO
(2) 12” x 62”
ETCHED VINYL STRIPS
(1) 15” x 32”
ETCHED VINYL LOGO
(1) 12” x 24”
ETCHED VINYL STRIP
CHRISTIAN BROTHERS
SINCE 1982
FCO LETTERS
T-2 RECEPTION / SERVICE FLOOR PLAN
10 :12
The purchaser agrees to hold the seller harmless against
any cause for action for damages which may occur as a
result of drilling for piers and foundations, including but not
limited to sewer, gas lines or any underground obstacles
which the purchaser or others may deem valuable.
8941 Crossroads Blvd
Chanhassen
MN 55317
Connie Keck
JW
Vx1100488-R2
07/21/20
10/16/20
This design and engineering is
submitted as our proposal, and
the right to use or exhibit in any
form, is not authorized without
written permission by Vixxo.
Address
City
State
Account Representative:
Notes
*
*
*
*
*
Designer
Design #
Original Date
Revision Date
All electrical scope to be completed in a U.L. approved
method and shall meet current N.E.C. standards
* All electrical components shall be U.L. Listed.
* Sign shall be grounded per N.E.C. Article 250.
* Insulated conductors as per N.E.C. Code 310.8.
type to be used - metallic insulated sealtite.
*Disconnect switch as per N.E.C. Code 600.6.
s i g n & l i g h t i n g
S CAL E: 1/4”=1’-0”
COLOR SCHEDULE
#07 ETCHED GLASS VINYL
GLASS ETCHED VINYL GRAPHIC
RECEPTION / WAITING
SERVICE
GLASS ETCHED VINYL
SPECIFICATIONS
1. #07 ETCHED GLASS VINYL OVERLAY.
2. OVERLAY APPLIED TO GLASS 2ND SURFACE
(BACK OF GLASS)
1Since9821Since982
CENTER
ON
GLASS
CENTER
ON
GLASS
CENTER
ON
GLASS
SI GN
5
12”
12”
62”73 ½”
(2) 12” x 73 ½” ETCHED VINYL STRIPS
(1) 15” x 32” ETCHED VINYL LOGO
(1) 12” x 24” ETCHED VINYL STRIP
(2) 12” x 62” ETCHED VINYL STRIPS
(1) 15” x 32” ETCHED VINYL LOGO
32”32”
24”
12”
15”
11 :12
The purchaser agrees to hold the seller harmless against
any cause for action for damages which may occur as a
result of drilling for piers and foundations, including but not
limited to sewer, gas lines or any underground obstacles
which the purchaser or others may deem valuable.
8941 Crossroads Blvd
Chanhassen
MN 55317
Connie Keck
JW
Vx1100488-R2
07/21/20
10/16/20
This design and engineering is
submitted as our proposal, and
the right to use or exhibit in any
form, is not authorized without
written permission by Vixxo.
Address
City
State
Account Representative:
Notes
*
*
*
*
*
Designer
Design #
Original Date
Revision Date
All electrical scope to be completed in a U.L. approved
method and shall meet current N.E.C. standards
* All electrical components shall be U.L. Listed.
* Sign shall be grounded per N.E.C. Article 250.
* Insulated conductors as per N.E.C. Code 310.8.
type to be used - metallic insulated sealtite.
*Disconnect switch as per N.E.C. Code 600.6.
s i g n & l i g h t i n g
I N T E R I O R L E T T E R FO R M S
9’-0”
1 ¼”5”
5 ½”
SC A L E: ¾”=1’-0”I N T E R I O R F L AT C U T O U T L E T T E R S E T E L E VAT I O N
(1) O N E S E T R EQ U I R E D
SCOPE O F WO RK
1. FA BRI CATE, SH IP & INSTA L L (1) O NE SE T FLAT CUT OUT LET T E RS.
SPECIFI CATI ON S
1. LETTERS: ¼” THICK SINTRA PAINTED FIRST SURFACE WHITE GLOSSY FINISH.
2. COP Y STY L E: CLA RE N D ON
3. LET TE RS MO U N TED FLUSH TO WALL WITH VHB TA PE AN D SI L ICONE.
SERVICE S C A L E: 1/4”=1’-0”
SI GN
6
1Since9821Since982
9"9"
CENTER
ON
WALL
CENTER
ON
WALL
EX A M P L E
¼” THICK SINTRA FORM
SECT ION D E TAI L
VHB TAPE WITH SILICONE
ADHESIVE AS REQUIRED
CO LO R S C H ED U L E
W HITE
5 ½"
1Since982
12 :12
The purchaser agrees to hold the seller harmless against
any cause for action for damages which may occur as a
result of drilling for piers and foundations, including but not
limited to sewer, gas lines or any underground obstacles
which the purchaser or others may deem valuable.
8941 Crossroads Blvd
Chanhassen
MN 55317
Connie Keck
JW
Vx1100488-R2
07/21/20
10/16/20
This design and engineering is
submitted as our proposal, and
the right to use or exhibit in any
form, is not authorized without
written permission by Vixxo.
Address
City
State
Account Representative:
Notes
*
*
*
*
*
Designer
Design #
Original Date
Revision Date
All electrical scope to be completed in a U.L. approved
method and shall meet current N.E.C. standards
* All electrical components shall be U.L. Listed.
* Sign shall be grounded per N.E.C. Article 250.
* Insulated conductors as per N.E.C. Code 310.8.
type to be used - metallic insulated sealtite.
*Disconnect switch as per N.E.C. Code 600.6.
s i g n & l i g h t i n g
WINDOW VINYL
S I G N
7
SCALE: 1 ½”=1’-0”
COLOR SCHEDULE
#07 ETCHED GLASS VINYL
WINDOW VINYL GRAPHIC ELEVATION
SATURDAYS
8AM - 2PM
20”
24”
12 ½”
24 ½”
36”
5 ¾”
1 ½”
1 ½”
1 ½”
1 ¼”
1”
1 ½”
1 ½”
SCALE: ¾”=1’-0”
Nice difference.SATURDAYS
8AM - 2PM
Nice difference.
(1) ONE REQUIRED
SPECIFICATIONS
1. #07 ETCHED GLASS VINYL OVERLAY.
2. OVERLAY APPLIED TO GLASS 2ND SURFACE
(INSIDE OFFICE)