Loading...
21 02-05 - Final Landscaping PlansCADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com Plotted: 02 /05 / 2021 12:31 PMW:\2020\20327\CADD DATA\LANDSCAPE\_dwg Sheet Files\L20327 L1-1 Landscape PlanOUCKSL QUALITY CONTROL PROFESSIONAL SIGNATURE SUBMITTAL/REVISIONS CADD QUALIFICATION DEER HAVEN CHANHASSEN, MN KEN ASHFELD 6480 YOSEMITE AVE. CHANHASSEN, MN 55331 11-09-20 PRELIMINARY SUBMITTAL 01-08-21 LOT LINES & GRADING 02-05-21 CONST DOCUMENTS C0-1 COVER SHEET C1-1 EXISTING CONDITIONS PLAN C1-2 DEMOLITION PLAN C2-1 SITE PLAN C3-1 GRADING & DRAINAGE PLAN C3-2 SWPP PLAN C3-3 SWPP NOTES & DETAILS C4-1 STORM SEWER PLAN C4-2 SANI. SEWER PLAN & PROFILE C8-1,2 DETAIL SHEETS L1-1 TREE CANOPY PLAN L2-1 LANDSCAPE PLAN L3-1 LANDSCAPE DETAILS Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Landscape Architect under the laws of the State of Minnesota. Gregory A. Johnson - LA Project Lead Drawn By Checked By Loucks Project No. 24610 20327 TWM GAJ TWM 02/05/21 02/05/21NSCALE IN FEET 0 30 60 TREE CANOPY PLAN L1-1 TREE CANOPY COVERAGE TREE CANOPY LEGEND EXISTING CANOPY COVERAGE TO REMAIN SITE BO U N D A R Y SITE BOUNDARY SITE BOUNDARYSITE BOUNDARY1 2 3 4 5 6 7 8 9 11 10 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 31 32 30 33 34 35 36 37 38 39 4540 44 41 46 48 50 47 49 42 43 51 52 53 58 34 54 56 5955 57 SIGNIFICANT TREE TABLE DISPOSITIONSPECIESDIAM / HT 2 TREE # MAPLE 1 ELM 3 4 5 6 7 8 23" 9 BOXELDER 10 12 15" 11 15" 13 14 19" 15 16 17 15" 18 19 20 22 21 23 24 25 26 27 28 29 30 SPRUCE PINE 16" PINE ASH ASH ASH ASH ASH ASH ASH ASH ASH ASH ASH ASH MAPLE MAPLE MAPLE MAPLE APPLE WALNUT WALNUT WALNUT WALNUT WALNUT SAVED SAVED REMOVED REMOVED REMOVED REMOVED SAVED REMOVED REMOVED REMOVED REMOVED REMOVED REMOVED REMOVED REMOVED REMOVED REMOVED REMOVED REMOVED REMOVED REMOVED 21.5" 17.5" 19.5" 11" 19" 17.5" 17.5" 17.5" 13" 18.5" 10" 10" 12" 12" 13.5" 13.5" 13.5" 15.5" 11.5" 11.5" 17" 25" 21" 29" REMOVED REMOVED REMOVED REMOVED REMOVED SAVED SAVED SAVED EXISTING CANOPY COVERAGE TO BE REMOVED 60 - 79 60 - 79 BOXELDER BOXELDER TREE PROTECTION FENCE - SEE 1/L1-1 TREE PROTECTION LOUCKS SCALE: 1/4" = 1'-0"Tree Protection.dwg4'-0"EXISTING GRADE TREE PROTECTION NOTE: INSTALL SNOW FENCE AROUND EACH TREE TO BE PROTECTED PRIOR TO GRADING. FENCE SHALL BE PLACED AT THE DRIP EDGE OR CRITICAL ROOT ZONES OF THE TREES. FENCING SHALL BE NO CLOSER THAN 6' TO THE TRUNK OF ANY TREE TO BE PROTECTED. THE PERIMETERS FOR TREES BEING PROTECTED SHALL BE DESIGNATED AT ALL TIMES DURING CONSTRUCTION ACTIVITY AND SIGNAGE SHALL BE INSTALLED AT ALL TREE PROTECTION AREAS THAT INSTRUCTS WORKERS TO STAY OUT. CONTRACTOR SHALL AVOID ALL AREAS WITHIN TREE PROTECTION FENCE. SOIL SHOULD BE PROTECTED FROM EROSION AND CHANGES IN CHEMISTRY FROM CONCRETE OR TOXIC MATERIALS SUCH AS FUELS AND PAINTS. THE CONTRACTOR SHALL HAVE "TREE PAINT" ON SITE AT ALL TIMES. IF AN OAK IS WOUNDED DURING CONSTRUCTION, THE CONTRACTOR MUST IMMEDIATELY APPLY PAINT TO THE WOUND IN ORDER TO PREVENT OAK WILT. ALL DAMAGE TO TREES TO BE PROTECTED SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER AND LANDSCAPE ARCHITECT.DRIP EDGE OF TREE2" X 4" WOOD STAKE, POSITIONED AS NOTED. STRING 4' HIGH, ORANGE POLYETHYLENE LAMINAR SAFETY NETTING BETWEEN WOOD STAKES PLACED 5' ON CENTER AND PLACED BETWEEN TREE PROTECTION AND DISTURBED AREAS.DRIP EDGE OF TREEEXISTING TREE TO REMAIN 1 DISPOSITIONSPECIESDIAM / HTTREE # 34 35 36 37 38 39 40 42 41 43 44 45 46 47 48 49 50 52 51 53 54 55 56 57 58 59 ASH ASH ASH ASH ASH ASH ASH ASH ASH ASH ASH BOXELDER BOXELDER BOXELDER ELM WALNUT PINE PINE PINE PINE PINE PINE PINE PINE PINE PINE SAVED SAVED SAVED SAVED SAVED SAVED SAVED SAVED SAVED SAVED SAVED SAVED REMOVED REMOVED REMOVED REMOVED REMOVED REMOVED REMOVED REMOVED REMOVED REMOVED REMOVED REMOVED REMOVED REMOVED 17.5" 13" 13" 13" 10" 10" 10" 12" 13.5" 15.5" 15.5" 17" 17" 25" 25" 11" 14" 12.5" 16.5" 22" 15.5" 11" 10.5" 14" 20" 19" 60-79 MISC *SAVED20x15" *TREES 60 - 79 ARE VARIOUS SPECIES AND SIZES LOCATED IN THE SOUTHERN PORTION OF THE PROPERTY. SINCE THEY WERE NOT INCLUDED IN THE SURVEY THEY ARE COUNTED AS A GROUP AND SIZED PER THE AVERAGE SIGNIFICANT TREE CALIPER ON THE PROPERTY. 32 31 33 ASH WALNUT ELM REMOVED REMOVED REMOVED 10" 11.5" 25" REMOVED NET SITE AREA OUTLOT 'A' AND PRIVATE ROAD EXISTING CANOPY COVERAGE REQUIRED MINIMUM CANOPY COVERAGE (LOW DENSITY RESIDENTIAL) PROPOSED CANOPY COVERAGE TO REMAIN DIFFERENCE BETWEEN PROPOSED CANOPY COVERAGE AND REQUIRED CANOPY COVERAGE =D-C A B C D E DESCRIPTION %SQUARE FEET ACRES TREE CANOPY CALCULATION 59,932 100% 1.38 46,996 122,379 27,878 0.64 2.81 40% 30% TOTAL AREA 150,257 3.45 45,077 1.03 31.2%1.08 3,789 ADDITIONAL CANOPY REQUIRED - 0 1 AB 1 AB 1 AB DECIDUOUS TREES QTY COMMON NAME BOTANICAL NAME SIZE CONTAINER AB 3 AUTUMN BLAZE MAPLE Acer freemanii `Autumn Blaze`B & B 2.5"Cal PLANT SCHEDULE GENERAL NOTES CONTRACTOR SHALL VISIT SITE PRIOR TO SUBMITTING BID. HE SHALL INSPECT SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS RELATING TO THE NATURE AND SCOPE OF WORK. VERIFY LAYOUT AND ANY DIMENSIONS SHOWN AND BRING TO THE ATTENTION OF THE LANDSCAPE ARCHITECT ANY DISCREPANCIES WHICH MAY COMPROMISE THE DESIGN AND/OR INTENT OF THE PROJECT'S LAYOUT. ASSURE COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS GOVERNING THE WORK OR MATERIALS SUPPLIED. CONTRACTOR SHALL PROTECT ALL EXISTING ROADS, CURBS/GUTTERS, TRAILS, TREES, LAWNS AND SITE ELEMENTS DURING PLANTING OPERATIONS. ANY DAMAGE TO SAME SHALL BE REPAIRED AT NO COST TO THE OWNER. CONTRACTOR SHALL VERIFY ALIGNMENT AND LOCATION OF ALL UNDERGROUND AND ABOVE GRADE UTILITIES AND PROVIDE THE NECESSARY PROTECTION FOR SAME BEFORE CONSTRUCTION / MATERIAL INSTALLATION BEGINS (MINIMUM 10' - 0" CLEARANCE). ALL UNDERGROUND UTILITIES SHALL BE LAID SO THAT TRENCHES DO NOT CUT THROUGH ROOT SYSTEMS OF ANY EXISTING TREES TO REMAIN. EXISTING CONTOURS, TRAILS, VEGETATION, CURB/GUTTER AND OTHER EXISTING ELEMENTS BASED UPON INFORMATION SUPPLIED TO LANDSCAPE ARCHITECT BY OTHERS. CONTRACTOR SHALL VERIFY ANY AND ALL DISCREPANCIES PRIOR TO CONSTRUCTION AND NOTIFY LANDSCAPE ARCHITECT OF SAME. THE ALIGNMENT AND GRADES OF THE PROPOSED WALKS, TRAILS AND/OR ROADWAYS ARE SUBJECT TO FIELD ADJUSTMENT REQUIRED TO CONFORM TO LOCALIZED TOPOGRAPHIC CONDITIONS AND TO MINIMIZE TREE REMOVAL AND GRADING. ANY CHANGE IN ALIGNMENT MUST BE APPROVED BY LANDSCAPE ARCHITECT. LANDSCAPE INSTALLATION COORDINATE THE PHASES OF CONSTRUCTION AND PLANTING INSTALLATION WITH OTHER CONTRACTORS WORKING ON SITE. NO PLANTING WILL BE INSTALLED UNTIL COMPLETE GRADING AND CONSTRUCTION HAS BEEN COMPLETED IN THE IMMEDIATE AREA. WHERE SEED ABUTS PAVED SURFACES, FINISHED GRADE OF SEED SHALL BE HELD 1" BELOW SURFACE ELEVATION OF TRAIL, SLAB, CURB, ETC. SEED ALL AREAS DISTURBED DUE TO GRADING. MULCH FOR TURF SEEDED AREAS SHALL BE TYPE 5 WOOD FIBER HYDROMULCH CONFORMING WITH MNDOT 3884. MULCH FOR SEEDED AREAS WITH SLOPES 15% OR GREATER SHALL BE MNDOT CATEGORY 1, STRAW RD 1S BLANKET CONFORMING WITH MNDOT 3885. ALL PLANT MATERIAL SHALL COMPLY WITH THE LATEST EDITION OF THE AMERICAN STANDARD FOR NURSERY STOCK, AMERICAN ASSOCIATION OF NURSERYMEN. UNLESS NOTED OTHERWISE, ALL SHRUBS SHALL HAVE AT LEAST 5 CANES AT THE SPECIFIED MINIMUM SHRUB HEIGHT OR WIDTH. ORNAMENTAL TREES SHALL HAVE NO V-CROTCHES AND SHALL BEGIN BRANCHING NO LOWER THAN 3' ABOVE ROOT BALL. STREET AND BOULEVARD TREES SHALL BEGIN BRANCHING NO LOWER THAN 5' ABOVE FINISHED GRADE. PLAN TAKES PRECEDENCE OVER PLANT SCHEDULE IF DISCREPANCIES IN QUANTITIES EXIST. SPECIFICATIONS TAKE PRECEDENCE OVER NOTES. NO PLANT MATERIAL SUBSTITUTIONS WILL BE ACCEPTED UNLESS APPROVAL IS REQUESTED OF THE LANDSCAPE ARCHITECT BY THE LANDSCAPE CONTRACTOR PRIOR TO THE SUBMISSION OF A BID AND/OR QUOTATION. ALL PROPOSED PLANTS SHALL BE LOCATED AND STAKED AS SHOWN ON PLAN. ADJUSTMENTS IN LOCATION OF PROPOSED PLANT MATERIALS MAY BE NEEDED IN FIELD. SHOULD AN ADJUSTMENT BE ADVISED, THE LANDSCAPE ARCHITECT MUST BE NOTIFIED. ALL PLANT MATERIALS SHALL BE FERTILIZED UPON INSTALLATION WITH A 27-3-3 SLOW RELEASE FERTILIZER MIXED IN WITH THE PLANTING SOIL PER THE MANUFACTURER'S INSTRUCTIONS. PLANTS MAY BE TREATED FOR SUMMER AND FALL INSTALLATION WITH AN APPLICATION OF GRANULAR 27-3-3 AT 6 OZ PER 2.5" CALIPER PER TREE AND 3 OZ PER SHRUB WITH AN ADDITIONAL APPLICATION OF 27-3-3 THE FOLLOWING SPRING IN THE TREE SAUCER. ALL PLANTS TO BE INSTALLED AS PER PLANTING DETAILS. REMOVE ALL FLAGGING AND LABELS FROM PLANTS. WRAPPING MATERIAL SHALL BE CORRUGATED PVC PIPING 1" GREATER IN CALIPER THAN THE TREE BEING PROTECTED OR QUALITY, HEAVY, WATERPROOF CREPE PAPER MANUFACTURED FOR THIS PURPOSE. WRAP ALL DECIDUOUS TREES PLANTED IN THE FALL PRIOR TO 12-1 AND REMOVE ALL WRAPPING AFTER 5-1. MULCH SHALL BE CLEAN SHREDDED HARDWOOD MULCH WITH UNIFORM PIECE SIZE. ALL TREES NOT IN PLANTING BEDS TO RECEIVE 4" DEEP MULCH WITH NO MULCH IN DIRECT CONTACT WITH TREE TRUNK. SPREAD GRANULAR PRE EMERGENT HERBICIDE (PREEN OR EQUAL) PER MANUFACTURER'S RECOMMENDATIONS UNDER ALL MULCHED AREAS. IF THE LANDSCAPE CONTRACTOR IS CONCERNED OR PERCEIVES ANY DEFICIENCIES IN THE PLANT SELECTIONS, SOIL CONDITIONS OR ANY OTHER SITE CONDITION WHICH MIGHT NEGATIVELY AFFECT PLANT ESTABLISHMENT, SURVIVAL OR GUARANTEE, HE MUST BRING THESE DEFICIENCIES TO THE ATTENTION OF THE LANDSCAPE ARCHITECT PRIOR TO PROCUREMENT AND/OR INSTALLATION. CONTRACTOR SHALL SUBMIT A WRITTEN REQUEST FOR THE OWNER ACCEPTANCE INSPECTION OF ALL LANDSCAPE AND SITE IMPROVEMENTS. CONTRACTOR IS RESPONSIBLE FOR ON-GOING MAINTENANCE OF ALL NEWLY INSTALLED MATERIALS UNTIL TIME OF OWNER ACCEPTANCE. ANY ACTS OF VANDALISM OR DAMAGE WHICH MAY OCCUR PRIOR TO OWNER ACCEPTANCE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR SHALL PROVIDE THE OWNER WITH A MAINTENANCE PROGRAM INCLUDING, BUT NOT NECESSARILY LIMITED TO, PRUNING, FERTILIZATION AND DISEASE/PEST CONTROL. CONTRACTOR SHALL GUARANTEE NEW PLANT MATERIAL THROUGH ONE CALENDAR YEAR BEGINNING ON THE DATE OF ACCEPTANCE BY THE LANDSCAPE ARCHITECT AFTER THE COMPLETION OF PLANTING OF ALL LANDSCAPE MATERIALS. NO PARTIAL ACCEPTANCE WILL BE CONSIDERED. UNLESS NOTED OTHERWISE THE APPROPRIATE DATES FOR SPRING PLANT MATERIAL INSTALLATION AND SEED/SOD PLACEMENT IS FROM THE TIME GROUND HAS THAWED TO JUNE 15. FALL SEEDING FROM AUGUST 15 - SEPTEMBER 15; DORMANT SEEDING IN THE FALL SHALL NOT OCCUR PRIOR TO NOVEMBER 1. FALL CONIFEROUS PLANTING MAY OCCUR FROM AUGUST 15 - OCTOBER 1 AND DECIDUOUS PLANTING FROM THE FIRST FROST UNTIL NOVEMBER 15. PLANTING OUTSIDE THESE DATES IS NOT RECOMMENDED. ANY ADJUSTMENT MUST BE APPROVED IN WRITING BY THE LANDSCAPE ARCHITECT. PROTECT ALL EXISTING OAKS ON SITE SCHEDULED TO REMAIN. IF EXISTING OAKS ARE DAMAGED IN ANY MANNER, ABOVE OR BELOW GROUND IN THE ROOT SYSTEM, AN ASPHALTIC TREE PRUNING PAINT SHOULD BE APPLIED IMMEDIATELY AFTER WOUNDING. OAKS ARE NOT TO BE PRUNED, REMOVED OR TRANSPLANTED BETWEEN APRIL 15 AND JULY 1. NOTIFY LANDSCAPE ARCHITECT IF THESE DATES ARE UNAVOIDABLE. LANDSCAPE CONTRACTOR SHALL ESTABLISH TO HIS SATISFACTION THAT SOIL AND COMPACTION CONDITIONS ARE ADEQUATE TO ALLOW FOR PROPER DRAINAGE AT AND AROUND THE BUILDING SITE. CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com Plotted: 02 /05 / 2021 12:31 PMW:\2020\20327\CADD DATA\LANDSCAPE\_dwg Sheet Files\L20327 L1-1 Landscape PlanOUCKSL QUALITY CONTROL PROFESSIONAL SIGNATURE SUBMITTAL/REVISIONS CADD QUALIFICATION DEER HAVEN CHANHASSEN, MN KEN ASHFELD 6480 YOSEMITE AVE. CHANHASSEN, MN 55331 11-09-20 PRELIMINARY SUBMITTAL 01-08-21 LOT LINES & GRADING 02-05-21 CONST DOCUMENTS C0-1 COVER SHEET C1-1 EXISTING CONDITIONS PLAN C1-2 DEMOLITION PLAN C2-1 SITE PLAN C3-1 GRADING & DRAINAGE PLAN C3-2 SWPP PLAN C3-3 SWPP NOTES & DETAILS C4-1 STORM SEWER PLAN C4-2 SANI. SEWER PLAN & PROFILE C8-1,2 DETAIL SHEETS L1-1 TREE CANOPY PLAN L2-1 LANDSCAPE PLAN L3-1 LANDSCAPE DETAILS Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Landscape Architect under the laws of the State of Minnesota. Gregory A. Johnson - LA Project Lead Drawn By Checked By Loucks Project No. 24610 20327 TWM GAJ TWM 02/05/21 02/05/21 LANDSCAPE PLAN L2-1 Gopher State One Call THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. WARNING SITE BO U N D A R Y SITE BOUNDARYSITE BOUNDARYNSCALE IN FEET 0 30 60 LANDSCAPE PLAN GROUNDCOVER LEGEND MNDOT NATIVE SEED MIX 33-261 STORMWATER MNDOT SEED MIX 25-131 LOW MAINTENANCE TURF LOUCKS Deciduous Tree Planting.dwgSCALE: 1/2" = 1'-0" 2x ROOT BALL WIDTH CONTRACTOR IS RESPONSIBLE FOR TESTING PERCOLATION RATES PRIOR TO PLANTING. NOTIFY LANDSCAPE ARCHITECT IMMEDIATELY IF POOR DRAINAGE EXISTS. SET PLANT ON UNDISTURBED NATIVE SOIL SCARIFY BOTTOM AND SIDES OF HOLE PRIOR TO PLANTING EDGE VARIES - SEE PLAN WOOD STAKE (OPTIONAL) MULCH - 4" DEEP. NO MULCH IN CONTACT WITH TRUNK - SEE NOTES OR SPECS. ROOT FLARE EVEN WITH OR JUST ABOVE GRADE. SAFETY FLAGGING - ONE PER WIRE TREE WRAP TO FIRST BRANCH 16"x2" POLYPROPYLENE OR POLYETHYLENE STRAP WATER TREE THOROUGHLY DURING PLANTING OPERATIONS. PLACE BACKFILL IN 8-12" LIFTS AND SATURATE SOIL WITH WATER. DO NOT COMPACT MORE THAN NECESSARY TO MAINTAIN PLUMB. CUT BACK WIRE BASKET PRUNE DAMAGED AND CROSSING BRANCHES AFTER PLANTING IS COMPLETE. THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL TREES IN A PLUMB POSITION THROUGH THE WARRANTY PERIOD. STAKING IS SUGGESTED, BUT NOT REQUIRED. ANY STAKING MUST CONFORM WITH PRACTICES AS DEFINED IN A.N.A. GUIDELINES FOR STANDARD PRACTICES BACKFILL WITH IN SITU TOPSOIL DECIDUOUS TREE PLANTING1